Loading...
HomeMy WebLinkAbout2524 Mohawk AveCITY OF SANFORD PERAUT APPLICATION Z, Permit No.: n J-.O' Job Address: rc Sw y /%%,040c/ Permit Type: -X-- Building Description of Work: Date: / I111a /O, 7 Electrical Mechanical Plumbing Fire Alzrm/Sprinkler 5; 410 UC1UR-e / Ale /?ArAJ 11l/DE .00S4 'r Additional Information for Electrical & Plumbing Permits Electrical: — Addition/Alteration _Change of Service _Temporary Pole _New AND Service (# of AMPS ) Plumbing/ Residential: Addition/Alteration New Construction (One Closet Plus Additional) Plumbing/ Commercial: Number of Fixtures Number of Water & Sewer Drainage Lines Number of Gas Lines Occupancy Type:,r Residential _Commercial _ Industrial Total Sq Ftg: Value of Workc f-2&--- Type of Construction: d yr11= GWd-Flood Zone: C Number of Stories:_ Number of Dwelling Units: Q Parcel No.: I (Attach Proof of Ownership &}LLeegal Description) Owner/ Address/Phone: avi a Lp .Sa trQlk- t • ,);,orG f /— .2%7 JAB \ _ 27 /_ /1br'n Contractor/ Address/Phone: d5KJ77t State License Number: Contact Person: 19V r O 7 4 Phone & Fax Number: / O -.2 32/--09s a Title Holder ( If other than Owner): C —41C Address: Bonding Company: Address: Mortgage Lender: Address: Architect/ Engineer Address: Phone No.: Fax No.. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work c:r installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws reguiating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management distress, state agencies, or federal agencies. of p er fi tion that I ill notify the owner of the property of the requirements of Florida Lien ,aw, FS 713. Z d Z o/ Ag t ate Signature of Contractor/Agent Date Print Owner/ Agent's Name 2 vt ature of Notary-S a of Florida Date M. JONWSON I SSION RCC921808I * p tdarch 23, 2004 f . I. c:. w'a M Notely So=_ices Owner/Agent is Personally Known to Me or Zl oduced ID R- 0 tr S 300 /lo V (orb ZB 20 Print Contractor/ Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known, to Me or Produced ID APPLICATION APPROVED BY: J A TZ,,r- Date: /02-' ZO 2rc;, vj Special Conditions: 14 5 /A_,o lac/ CITY OF SANFORD BUILDING DIVISION OWNER/BUILDER AFFIDAVIT CONSTRUCTION CONTRACTING Owners of property when acting as their own contractor and providing direct, onsite supervision themselves of all work not performed by licensed contractors, when building or improving farm outbuildings or one -family or two-family residences on such property for the occupancy or use of such owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such structure by the owner -builder within 1 year after completion of same creates a presumption that the construction was undertaken for purposes of sale or lease. This subsection does not exempt any person who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The owner may not delegate the owner's responsibility to directly supervise all work to any other person unless that person is registered or certified under this part and the work being performed is within the scope of that person's license. For the purposes of this subsection, the term "owners of property" includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this subsection, an owner must personally appear and sign the building permit application. State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct, onsite supervision of the construction yourself. You may build or improve a one -family or two-family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who ' not h ensed must work under your direct supervision and must be employed by you, w h means a you st deduct F.I.C.A. and withholding tax and provide workers' compensation for t e ploy all p cribed by law. Your construction must comply with all applicable laws. Ord' s, bu' in ode , and z ing regulations. I, do hereby state that I am qualified and capable of performing the r ed co ruction involved with the permit application filed. I will assume full respons ity as an Owner/Builder Contractor, and will personally supervise all work al %ve by law on tjte p rr fitted structure. 91vrl6rBuild6 Signature /Datd Nt)11*:$ 1^sc Print Owner/Builder Name ignature of Notary-S a of Florida Date ?°' `* JO ANN M. JOHNSON MY COMMISSION # CC 921JjEXPIRES: March 23, 200J reov n aondd7ft,u cudgel Notary Servi Owner is Personallv Known to Me or Ni Produced ID S 3uo /(e 4 (og Z F*-O ^ PLAT . OF SURVEY nT ` A10DESCRIPTION REGO1tpt U IN FLATi $v^vK PAGE (S7 9C f 9/ OF THE PUBLIC RECORDS OF S M/NU[ COON' ' , 3r (V tE'SS D/r _ 4 7 '. i,3©oo a I cr-ALE ra pWWy DOES NOT UE WITHIN THE r, -,e 7 FIWABLISpEDIDOYEARRMPRONEAREOL4,l/PF r/rG€, ft c00 TQNE C E VIZ./ !M,#N SWAGGERTY LAND SURVEYING, INC. 3S50 S.R. 46 M. SANFORD, FLORIDA 32771 t4 07 i 322- 46W N[RO Cgo ritT Ir MT TMI[ oVINZY = NC11Lp Nµ; b"Ic jigAccost-"Mcf To - DATE OF: smovey1No IN TN[ STATe of FLoRiDA DARY CN 4-Firof.7 AND CH 411 : MN-• 1'Jc VoUmo CERTIFIED CORRECT nNAL SEf / ,T zo S. R as E . REG. LAND SURVE'C' n rn 0 WOOD — CHAPTER 3 308.4 COLUMN CONNECTIONS 308.4.1 The columns shall be fastener accordance with Section 2306 of the Standard Building Code. In addition, uplift conne, 'he uplift loads shown in Table 308F. 308.4.2 Uplift load requirements may bi _jilding widths. TABLE 308F MINIMUM UPLIFT LOADS FOR COLUMN TO GIRDER CONNECTIONS 90 mph 100 mph 110 mph Building Width 4' 16' 1 24' 1 32' 40' 4' 15' 1 24' 32' 1 40' 4' 1 16' 1. 24' 1 32' 40' Col. Spacing 1'O.C. 79 184 255 327 398 107 250 348 446 543 138 324 450 577 704 2'o.c. 175 375 525 650 800 225 500 700 900 1100 275 650 900 1150 1425 3'O.C. 250 550 775 1000 1200 325 750 1050 1350 1625 425 975 1350 1750 2125 4'0.C. 325 750 1025 1325 1600 425 1000 1400 1800 2175 550 1300 1800 2325 2825 6'O.C. 475 1100 1550 1975 2400 650 1500 2100 2675 3275 825 1950. 2700 3475 4225 8'O.C. 650 1475 2050 2625 3200 875 2000 28W 3575 1100 2600 3600 4625 10'o.C. 800 1850 2550 3275 1075 2500 3500 1400 3250 4500 12'o.C. 950 2225 3075 1300 3000 1675 3900 14' o.c. 1125 2575 1500 1950 16' o.c. 1275 1725 18' o.c. 1425 I - 308.5 GIRDERS Girders shall be designed in accordance with Section 2307.2 of the Standard Building Code and the American Forest and Paper Association's (AF&PA) Wood Structural Design Data using accepted roof dead and live load conditions. 308.6 ROOF SYSTEM The roof system shall be designed in accordance with 307. 309 EXTERIOR WALL VENEERS 309.1 INSTALLATION Exterior wall veneers shall be installed in accordance with Section 2403 of the Standard Building Code. 1997 SBCCI Standard for Hurricane Resistant Residential Constructionm 119 WOOD — CHAPTER 3 , 308.2.4 Columns Supporting Open Unattached Structures: Minimum requirements for columns supporting open unattached structures are shown in Table 308D. TABLE 308D , MINIMUM Fb FOR COLUMNS SUPPORTING' OPEN UNATTACHED STRUCTURES 90 mph 100 mph Structure Width Column Spacing Size 4' 2' o.c. 4x4 T o.c. 6x6 4' o.c. 6x6 6' o.c. 8' Pole 8' o.c. 8' Pole 10' o.c. 10' Pole 12' o.c. 10* Pole 16' 2' o.c. 6x6 T o.c. 6x6 4' o.c. e' Pole 6' o.c. 10, Pole 8' o.c. 101 Pole 40' 7 o.c. 6x6 T O.C. 8' Pole 4' o.c. 8' Pole Fb (psi) Size Fb (psi) 1000 4x4 3150 S00 6x6 700 1100 6x6 1100 2400 8' Pole 2400 2400 8' Pole 2400 2400 10* Pole 2400 2400 500 6x6 700 1100 8' Pole 2400 2400 8' Pole 2400 2400 10, Pole 2400 2400 1100 6x6 1100 2400 8' Pole 2400 2400 10' Pole 2400 SIM 4x4 6x6 8' Pole 8' Pole 10, P 10' P 6x6 8' Pole 8' Pole 10* Pole 8' Pole 8' Pole 10, Pole Pole Pole 110 mph Fb (PSI) 1450 700 2400 2400 2400 2400 700 2400 2400 2400 2400 WOOD — CHAPTER 3 308.4 COLUMN CONNECTIONS 308.4.1 The columns shall be fastenet Building Code. In addition, uplift connet 308.4.2 Uplift load requirements may bt TABLE 308F MINIMUM UPLIFT LOADS FOR COLUMN TO GIRDER CONNECTIONS accordance with Section 2306 of the Standard he uplift loads shown in Table 308F. jilding widths. 90 mph 100 mph 110 mph Building Width 4' 16' 1 24' 32' 1 40' 4' 1 16' 1 24' 1 32' 40' 4' 1 16' 24' 1 32' 1 40' Col. Spacing 1'O.C. 79 184 255 327 398 107 250 348 446 543 138 324 450 577 704 2'O.C. 175 375 525 650 800 225 500 700 900 1100 275 650 900 1150 1425 3'O.C. 250 550 775 1000 1200 325 750 1050 1350 1625 425 975 1350 1750 2125 4'0.c. 325 750 1025 1325 1600 425 1000 1400 1800 2175 550 1300 1800 2325 2825 6'o.c. 475 1100 1550 1975 2400 650 1500 2100 2675 3275 825 1950. 2700 3475 4225 8'O.C. 650 1475 2050 2625 3200 875 2000 2800 3575 1100 2600 3600 4625 10'o.c. 800 1850 2550 3275 1075 2500 3500 1400 3250 4500 12'o.c. 950 2225 3075 1300 3000 1675 3900 14' o.c. 1125 2575 1500 1950 16' O.C. 1275 1725 18' O.C. 1425 308.5 GIRDERS Girders shall be designed in accordance with Section 2307.2 of the Standard Building Code and the American Forest and Paper Association's (AF&PA) Wood Structural Design Data using accepted roof dead and live load conditions. t` 308.6 ROOF SYSTEM The roof system shall be designed in accordance with 307. 309 EXTERIOR WALL VENEERS 309.1 INSTALLATION Exterior wall veneers shall be installed in accordance with Section 2403 of the Standard Building Code. 1997 SBCCI Standard for Hurricane Resistant Residential Constructionm 119 4"1N-M BETLJE 4LTERN,4TE LA H5 OPTIONAL F46CIA DTL. A TI /1 I r r1 i im ir-T. FURL IN SEL I CELL. 4• = 9a" 1510 = 225" OK 80* 750 = 225" OK TL. PN"..015 TH< ICsN LOAD = 70 P5F ACN UP (5) l 1/2" X 012 EW5 m 3(o" O/C 30" RAFTER5 6 30" O/C Q City of Sanford Model Codes in effect: Standard Building Code 1997 ed. Standard Plumbing Code 1997 ed. Standard Mechanical Code 1997 ed. National Electrical Code 1996 ed. See City Code AMENDMENTS I`L. Accessiblilty Codog 199y KL: kfikgV G000 1087 SANFORD BUILDING DEPT. THESE PLANS ARE REVIF WED AND CONDITIONALLYACCEPTEDFORPRA91T. A PERMIT ISSUED SHALL BECONSTRUED1'O SE A LICEf gG TO PROCEED WITHTHEWORKANDNOTAS 'AUTHORITY TO VIOLATE, CANCEL., ALTE41 OR SET ASIDE ANY OF THE ISSUANCEPROVISIONS OF THE TECH?;ICAI_ CC6us: NOR SHALLDEPT' FROMOTHERF I"IT PREVENT -10E BUILDINGTIONA•'TER REQUIRING A CORREC- OF ERRORS ON THE PLANI ; CONSTRUCTIONOROTHERVIOLATIONSOFTHECOS _-S. PERMIT # oz s8 OFFICr n E COI Y