HomeMy WebLinkAbout2920 W Airport BlvdCITY OF SANFORD ELECTRICAL PERMIT APPLICATION Permit Number: 1 Z ? Date: S The undersigned hereby applies for a permit to install the following electrical: Owner's Name: &ZPAJ, X ' 4_2 ST/ IS Address of Job: /41MRr Ekvb FL , 3 z7-7J Electrical Contractor: 191-1 L-C Ssxsr lg --i) l•JC Ho-1 -331 — 291,,( Le.-LAr\ Donn Residential: Non -Residential: Number Amount Addition, Alteration, Repair (Residential & Non -Residential) New Residential: AMP Service New Commercial: AMP Service Change of Service: From AMP Service to AMP Service Manufactured Building Other: Description of Work: EOL.ACl n snN LA t?.4' .vTPne L. NO O F7i £,t c VE LI)> E Application Fee: 10.00 TOTAL DUE: By Signing this application I am stating that I am in compliance with Cit -of Sanford Electrical Code. ClG2c,a, .0 cvc• Applicant's Signature State License Number CITY OF.SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: — /0 1 0,;) - BUSINESS NAME / PROJECT: ADDRESS: PHONE N .: lT—%/> % J-- FAX NO.: IL ci S CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW [ ] F. A. F.S. [ ] HOOD [ ] PAINT BOOTH V BURN PERMIT,[ ] /I TE P RMIT I,1 // TANK PERMIT I 1 OTHER I 1 '-Q 4c c'sS a !A•JC: ,L TOTAL FEES: S C o ( PER UNIT SEE BELOW) COMMENTS: Address / B1dQ. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. ,J= 4. 5. -c? Lee 6. 7. 8. 9. 10. 12. _ 13. 14. 15. 16. 17, 18. 19. 20. 0 M 0 z Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of San, Florida. Sanford Fire vention Division Applicant' Signatu SANF'ORD SUnn'Na Dom- THFS[ PLAtJS ARE RcvlF_WeO AND GONDITIONALI.E pTCU OR pERrA1". A F'ERMi7 I^SUED SHALYWITH AC:G A Li,ENSE TO "C)CEEO 7HGRITY TO VIOLATE. rr N;Tttl!FD TO tlOr A-, AU ANY OF THEPlU: Vr;I;I ADlI)R Ur2 5ET A5IDF_ HALL CAN:.'7 I- AI-' ``TI IC E." r„JIGAL C OUES. NCR SFO'P„t,Na C F RCVENT 1 HE E3UILDING 1'':SIIANi:of A FLr1MIT F iiEOUIRING A CORREC- t3 1 7 FI UM YrIFRr-AFTI: , nn S7RUCTiON tlt N F €,RRUMi ON 'THE FROTN&R v,OL,T1oN5 OF Tr RECEIV MAY 1 0 2002 One Class A (Style D) waterflow zone Four Class B (Style A) 2-wire smoke detector zones 100mA 12 VDC switched 4-wire smoke power (XR5FC) Two Form C relay outputs Four open collector outputs for annunciation Built-in dual phone tine module with line monitoring Built-in bell circuit trouble monitor, connects to Model 865 or 866 Notification Circuit Modules 1.5 Amp alarm bell output (XR5FC) 500mA auxiliary output Operates on 16 VAC or 24 VDC primary power and 12 VDC secondary power Compatible with a variety of LED and LCD keypads One-man Walk Test PERMIT # o iz4i8 OTRU COPY' The XR5FC Commercial Fire and XR5SL Slave Communicator panels from DMP are perfect for small commercial installations that require an economical and reliable fire alarm system. Fire Drill feature for practice evacuations DMP SDLC, Contact ID, or 4-2 communication Programmable reporting to one or two central stations Remote upload/download with Remote Link" Individual zone programming for fire, fire verification, retard delay, cross -zoning, and fire supervisory Cross -zoning between any zones Swinger bypass option on all zones Inherent power limited circuits 4-wire keypad and annunciator circuit Built-in plain English programming from any keypad 16 event history can be viewed from any alpha keypad Pager DirectTm communication to numeric pagers Automatic Recall Test reporting Automatic Standby Battery Test 508 8 Amps @ 12 or 24 VDC 690 32-char. LCD Keypad Remote Link'" Programming Software690FFireCommand"' 32-char. LCD System Link"' End -User Software 692F Fire Command"' Keypad Alarm Monitoring"' Module7704-zone VFD Keypad Command Center"" Visual Command and 771 4-zone VFD Keypad with Control Module internal relay 790 4-zone LCD Keypad 790F 4-zone LCD Fire Command SLR-835B Photoelectric Smoke 791 4-zone LCD with internal relay 521B/BXT Addressable Smoke, CleanMe 793 4-zone LCD with internal relay, 521LX/LXT Addressable Smoke/Heat, Prox CleanMe ePAD Easy -to -Use Internet Keypad 600 Series Heat Detectors 3045 Sentrol Panic Switch 5515G Sentrol Moisture Sensor 377 Trouble Annunciator Module requires 5501) included with XRSSL) 5501 Sentrol Moisture Processor 860 Relay Module 865 Style Y/Z Notification Circuit Module 801 Piezoelectric Mini -horn 866 Style W Notification Circuit 802 Mutitone Notification Module Appliance 867 LX-Bus Notification Circuit 803 Horn Appliance Module 806 Motor Bell 869 Style D Initiating Circuit Module 821 Sync/Non-Sync Strobe 893/A Dual Phone Line Module 822 Sync/Non-Sync Strobe Plate 995 Voice Module 823 Horn/Strobe Appliance 831 Single Sync Module 832 Dual Sync Module 502-12 Provides 2 Amps @ 12 VDC 850D Dual Action Fire Alarm Pull 502-80 80-hour Standby Charger Station 504-24 Provides 4 Amps @ 24 VDC 505-12 Provides 5 Amps @ 12 VDC Primary Power 16.5 VAC 40VA transformer (Model 320) Secondary Power 12 VDC 7.7 Ah battery (Model 367) Auxiliary Output 500mA @ 12 VDC Alarm Output 1.5 Amps @ 12 VDC (XR5FC) Smoke Output 100mA @ 12 VDC (XR5FC) Annunciator Outputs 50mA each (switched ground) Dimensions 12.5" x 9.5" x 3.75" 800 641 4282 WWW.DMP.CO 850S Single Action Fire Alarm Pull Station 300 Plug-in 305 Plug-in Relay Output 306 Tamper Harness 318 Dual Battery Harness 320 40VA Wire -in Transformer 321 40VA Plug-in Transformer 322 100VA Wire -in Transformer 349 Medium Enclosure 350 Large Enclosure - room for 4 batteries 350A Attack Resistant Enclosure 367 12 VDC 7.7 Ah battery 370RJ Lightning Suppressor with 2 RJ Jacks 394 Direct Programming Cable Secure -Corn Cellular 381 Cellular Handset 385 3dB Gain Cellular Antenna 430 Output Harness 708 Buss Extender Module Underwriters Laboratories - S3598 UL 864 NFPA 72 Central Station NFPA 72 Local Protective Signaling NFPA 72 Remote Station Protective Signaling California State Fire Marshal - 7165-1157:104 NYC MEA - 168-93-E 2500 N. PARTNERSHIP BLVD., SPRINGFIELD, MISSOURI 65803-8877 Model 377 Trouble Main Backup MODEL XR5 Saencolteset Annunciator 1701 Push for One Second Module 3 Panel Reset1-1 Silence/Reset Telephone. Cmnn0— Header 0 Trouble Annunciator Header r, no 0 Relay Sockets for Optimal Direct connect to Form C -1V1., s on J31 unsvritched 120 VAC 60 Hz O J14 Bell Monitor Requires Model 305 Rebys 1 sM RED 11 1R air 71A-Z1A- Z:aa7:6- 72- 21 13 71- Z6 74 71 75- OSa j J12 7 431 1 2 3 s 6 7 9 9 0 1 2 1 4 s 1 17 I 9 Z 1 2 ycmrrVr+x- Modd 320 virein transformer W Zone 5 if ; VAC 40VA Output Header S S 3.3k Ohm ro. open CoNwra WpAs. SUM U 30 VDU esf ve m 4 tires Mt M 300 H Secondary Power Supply m W b 1.2 Amps max. charging current. Zone 1 OSAp1A i output 2 s t s S S Output Header 311 Bell C"t cad watte7 Plpe Two Form C (SPOT) Ouqus. 1.5 Amps @ 12 VDC Eitls C—W r N lOk Ohm C-0L 331,Otm 331,ohm SmYrt! Snxle Resist. dr.m dery Mode1308` Zone 4 3.3k Ohm p Red ay w.. I I Blade Model 866 , aro lass B (Style w) up re 1()omA of ectrmt 15 available for Power Nodflcatfon Orcuit Module 1, 4-wire spoke detectors from terminal 6. Supervision 37 MA 0 12 VDC eel ov , Relay eai *ouvr Oei 1%mk Keypad Keypad Model 692F Model 770 40rnA @ 8 to 16 VDC 100mA at 8 to 16 VDC DODO O O O O Keypad 0 0 0 0 00 0 0 ell 690 CD CD CD O up to S00mA auxiliary p CD CD CD p VDC cument0I2vOC6.n - OOOO 0000 Terminal? - 1&CharacterKeypads 10 Zone LED Keypads 32-Character Keypads XR5FC System Configuration Diagram The XR5 panels feature built-in 2-line dialers, 500mA of auxiliary power, one Class A (Style D) zone for sprinkler supervision, four Class B (Style A) smoke detector zones, 12 or 24 VDC input, two Form C outputs, four annunciator outputs, and a 4-wire bus for remote LED or LCD annunciators. Both panels also provide outstanding software features such as one-man walk test, passcode protected operation, cross - zoning, fire verify and fire retard zone programming, built-in programmer and diagnostics, and remote upload/download capability. There's also a Fire Drill feature that allows an authorized user to sound just the system's bells for evacuation exercises. The following sections highlight the unique features of the XRSFC and XRSSL fire panels. The XR5 panels each contain a built-in dual phone line module with line supervision and can communicate to one or two remote receivers using Synchronous Data Link Control (SDLC) digital dialer, Contact ID CID), or 4-2 formats. You can also selectively enable alarm, supervisory/ trouble, backup, and recall test reporting to either of the two receivers. The XR5 can send Alarm and Trouble reports directly to a user's numeric pager. Pager Direct is a must -have feature for anyone needing instant updates on the status of their system. You can remote program the XR5 panels using Remote Link'"' programming software from DMP to load programs into new accounts or make copies of existing programs. You can also upload the 16 event memory for diagnostic purposes. The XR5 panels also contain an internal English text Programmer that allows installers and service technicians to easily program and test the panels from an alphanumeric keypad connected to the remote annunciator bus. For system annunciation, you can select from several keypad styles to meet a variety of fire system requirements. The Model 692F LED keypad provides individual alarm and trouble LEDs as well as power, system trouble, and silenced LEDs along with a full function, backlit keyboard. You can also choose from 770, 690F, or 790F series alphanumeric keypads. Both LED and alphanumeric keypads meet all requirements for local system operation. For slave communicator applications, an enclosure door mounted Model 377 Trouble Annunciator Module provides Trouble and System OK LEDs with audible alert and a Silence button for acknowledging trouble conditions. This module is included with the XRSSL. You can now conduct one-man tests of the system and all connected devices using the Walk Test feature. A fire technician simply enters an access code into the keypad and the XR5 panels automatically enter the test mode. Each time a zone is tripped during the test, the bell rings for two seconds and a Sensor Reset is automatically performed to reset any latched detectors. When the test is completed, the results are displayed at the keypad and can be sent to the central station. The built-in false alarm reduction features include Cross -Zoning, Fire Verification, Fire Retard, and CleanMeTm reporting. Cross - zoning allows multiple zones to report alarms only when two or more are tripped. Should just one zone trip, a zone fault report is sent to the central station. Fire Verification provides a 120 second window during which a smoke detector can trip, be automatically reset, and then must trip a second time before an alarm is indicated. A single trip on the zone sends just a zone fault report to the central station. Fire Retard allows a programmable time of up to 250 seconds for waterflow detection. This eliminates the need for additional mechanical delays at the flowswitch. The XR5 panels operate on either 16 VAC from a wire -in transformer or 24 VDC from a main Fire Alarm Control Panel (FACP). This allows the panels to be used as stand alone communicators or FACPs. When powered from the 24 VDC input of a larger FACP, the panels can operate as slave communicators with 12 VDC auxiliary output capability. Four open collector annunciator outputs and two optional Form C dry contact relays are provided on the XR5 panels for a variety of remote control and annunciation applications. E S L P R O D U C T I N FORMATION B U L L E T 1 N CleanMeTM remote maintenance reporting reduces false alarms Smart dual fixed/rate of rise heats work with photo chamber to catch fires faster Built-in drift compensation reduces false alarms Field replaceable optical chamber makes servicing a snap Small, low profile design blends in with any environment CleanMe"' COMPATIBLE For a current list of CleanMe compatible control panels, go to www.sentrol.cont/products/esi and click on the CleanMe logo. 521 SERIES Low Profile, Self -Diagnostic, Two - Wire, Photoelectric Smoke Detector with CleanMe TM UL Model numbers: 52113, 521 BXT, 521 C RXT ULC Model numbers: 5288, 528BXT Q,' California State Fire Marshal Approved LISTED The ESL 521 Series self -diagnostic, two -wire smoke detectors are the industry's first conventional direct -wire smoke detectors with analog features such as remote maintenance/trouble reporting (CleanMeTM'), drift compensation, and multi -criteria detection. The 521 Series continually monitor their own sensi- tivity and operational status, and provide a visual and remote trouble condition if they drift out of the sensitiv- ity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. The 521 has a unique feature enabling it to send a signal (CleanMe) to the ESL 505 module (sold separately) when it has drifted outside of its UL Listed sensitivity range or has failed its internal diagnostics test. The 505 is an interface module that will signal any panel via relays when the 521 is dirty. Several control panels have the CleanMe software built in, eliminating the need for the 505 module. When CleanMe is not desired, simply leave the switch on the 521 off and it will work as a normal two wire detector. CleanMe allows the installer time to schedule a service call and avoid a false alarm. Time between cleaning detectors is dramatically increased because of the 521's built-in drift compensa- tion. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing dust life. And when the 521 has told you that cleaning is necessary, it's literally a snap with ESL's patented field replaceable optical chamber. continued 521 Series ESL Photoelectric Smoke Detectors The multi -criteria model 521XT photoelectric smoke detector/fixed rate of rise heat detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photo- electric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelec- tric sensor increases allowing it to detect smaller particles of combustion faster. Architectural and Engineering Specifications The ESL 521 Series photoelectric smoke detector is a low - profile, self -diagnostic , two -wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 field sensitivity requirements without the need for external meters. Built-in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm. See installation instructions for information about correct installation and maintenance. The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Dimensions: 2" (5cm) -- - -- 5" (12c Specifications: Product Data Voltage..... Dip switch 1 "on" 6.5 — 33 VDC, polarity sensitive Dip switch 1 "off" 8.5 — 33 VDC, polarity sensitive Maximum ripple (pk to pk).................................... 10% (V P) Typical average standby current (24V) ......................... 761JA Typical alarm current (24V) ................ up to 60mA max, if not limited by control panel Alarm Contacts .........................500mA @ 36 VDC (resistive) Aux. Relay contacts ............ 2A @ 30 VDC, 1 A @ 120 VAC Sensitivity — photoelectric .................. 3.1 % + 0.50 — 1.00% Operating temperature ............... 32'F to 100'F (0' to 37'C) Operating humidity range ............ 0 to 95% Non -condensing RFI Immunity ......................... 20 V/m minimum; 0-1000MHz Color .................................................... White head and base Field wiring size ......................................... :......... 12-24 AWG Detector packaging ............................10 detectors per carton Heat detector specifications .. Rate of rise — 15`F/min and > 105°F (8.3"C/min and > 40.6°C) Fixed — 135'F (57°C) UL two -wire compatibility identifier.... Dip switch 1 'on" S09A Dip switch 1 "offS10A, S11A Drift compensation adjustment ........................... 1.0%/ft. max Detector head dimensions ...................... 5" (12 cm) diameter 2" ( 5 cm) height Mounting dimensions ..................... 4.75" (12.5 cm) diameter; 0. 3" (0.8 cm) height Reset time.................................................1 second minimum Listings........................................................ UL, ULC, CSFM Model No. Description 521 B 2-wire, photoelectric, 6-24 VDC, UL listed 521 BXT 2-wire, photoelectric, 6-24 VDC, multi -criteria algorithms, fixed/rate of rise heat, UL listed 521 B-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with CleanMeM not individually boxed 521 BXT-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with fixed/rate of rise smart dual heat and CleanMe not individually boxed 521CRXT 2-wire, photoelectric, 12-24 VDC, aux. relay, multi -criteria algorithms, fixed/rate of rise heat, UL listed 528B 2-wire, photoelectric, 6-24 VDC, ULC listed 528BXT 2-wire, photoelectric, 6-24 VDC, multi -criteria algorithms, fixed/rate of rise heat, ULC listed Accessories 505 Module that interprets the 521's CleanMe signal for panel and can convert 2-wire 521 Series to 4-wire inputs on panel 401 Test magnet in plastic shell for pole mounting SM- 200 Smoke! in a CanQ4 (canned smoke) for functional testing of smoke detectors 211 Replacement optical chambers (set of 10) Vc 1998 Sentrol, Inc. Certain of the items in the Product Information Bulletin are protected under one or more of the following patents: 5,546,074; 5,708,414; 5, 798,701; 5,821,666. SENTROL Sentrol reserves the right 12345 SW Leveton Dr., Tualatin, OR 97062 to change specifications without notice. Tel.: 503.692.4052 Fax: 503.691.7566 ESL Pd http:/lwww.sentrol.com ®1999 Sentrol U.S. & Canada: 800.547.2556 Technical Service: 800. 648.7424 A PRODUCT OF SENTROL FaxBack: 1.800.483.2495 E-3753-FLG25K-0399