HomeMy WebLinkAbout2920 W Airport BlvdCITY OF SANFORD ELECTRICAL PERMIT APPLICATION
Permit Number:
1 Z ? Date: S
The undersigned hereby applies for a permit to install the following electrical:
Owner's Name: &ZPAJ, X ' 4_2 ST/ IS
Address of Job: /41MRr Ekvb FL , 3 z7-7J
Electrical Contractor: 191-1 L-C Ssxsr lg --i) l•JC Ho-1 -331 — 291,,(
Le.-LAr\ Donn
Residential: Non -Residential:
Number Amount
Addition, Alteration, Repair (Residential & Non -Residential)
New Residential:
AMP Service
New Commercial:
AMP Service
Change of Service:
From AMP Service to AMP Service
Manufactured Building
Other:
Description of Work: EOL.ACl n snN LA t?.4' .vTPne
L. NO O F7i £,t c VE
LI)> E
Application Fee: 10.00
TOTAL DUE:
By Signing this application I am stating that I am in compliance with Cit -of Sanford Electrical Code.
ClG2c,a, .0 cvc•
Applicant's Signature
State License Number
CITY OF.SANFORD FIRE DEPARTMENT
FEES FOR SERVICES
PHONE # 407-302-1091 * FAX #: 407-330-5677
DATE: — /0 1 0,;) -
BUSINESS NAME / PROJECT:
ADDRESS:
PHONE N .: lT—%/> % J-- FAX NO.:
IL
ci
S
CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW [ ]
F. A. F.S. [ ] HOOD [ ] PAINT BOOTH V BURN PERMIT,[ ] /I
TE P RMIT I,1 // TANK PERMIT I 1 OTHER I 1 '-Q 4c c'sS a !A•JC: ,L
TOTAL FEES: S C o (
PER UNIT SEE BELOW)
COMMENTS:
Address / B1dQ. # / Unit # Square Footage Fees per Bldg. / Unit
1.
2.
3. ,J=
4.
5. -c? Lee
6.
7.
8.
9.
10.
12. _
13.
14.
15.
16.
17,
18.
19.
20.
0
M
0
z
Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407-
330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take
place. I certify that the above is true and correct and that I
will comply with all applicable codes and ordinances
of the City of San, Florida.
Sanford Fire vention Division Applicant' Signatu
SANF'ORD SUnn'Na Dom-
THFS[ PLAtJS ARE RcvlF_WeO AND GONDITIONALI.E
pTCU OR pERrA1". A F'ERMi7 I^SUED SHALYWITH
AC:G A Li,ENSE TO "C)CEEO
7HGRITY TO VIOLATE. rr N;Tttl!FD TO tlOr A-, AU ANY OF THEPlU: Vr;I;I ADlI)R Ur2 5ET A5IDF_ HALL
CAN:.'7 I- AI-' ``TI IC E." r„JIGAL C OUES. NCR SFO'P„t,Na C F RCVENT 1 HE E3UILDING
1'':SIIANi:of A FLr1MIT F iiEOUIRING A CORREC-
t3 1 7 FI UM YrIFRr-AFTI: , nn S7RUCTiON
tlt N F €,RRUMi ON 'THE FROTN&R v,OL,T1oN5 OF Tr
RECEIV
MAY 1 0 2002
One Class A (Style D) waterflow zone
Four Class B (Style A) 2-wire smoke detector zones
100mA 12 VDC switched 4-wire smoke power (XR5FC)
Two Form C relay outputs
Four open collector outputs for annunciation
Built-in dual phone tine module with line monitoring
Built-in bell circuit trouble monitor, connects to
Model 865 or 866 Notification Circuit Modules
1.5 Amp alarm bell output (XR5FC)
500mA auxiliary output
Operates on 16 VAC or 24 VDC primary power and
12 VDC secondary power
Compatible with a variety of LED and LCD keypads
One-man Walk Test
PERMIT # o iz4i8
OTRU COPY'
The XR5FC Commercial Fire and XR5SL Slave
Communicator panels from DMP are perfect for small
commercial installations that require an economical
and reliable fire alarm system.
Fire Drill feature for practice evacuations
DMP SDLC, Contact ID, or 4-2 communication
Programmable reporting to one or two central stations
Remote upload/download with Remote Link"
Individual zone programming for fire, fire verification, retard
delay, cross -zoning, and fire supervisory
Cross -zoning between any zones
Swinger bypass option on all zones
Inherent power limited circuits
4-wire keypad and annunciator circuit
Built-in plain English programming from any keypad
16 event history can be viewed from any alpha keypad
Pager DirectTm communication to numeric pagers
Automatic Recall Test reporting
Automatic Standby Battery Test
508 8 Amps @ 12 or 24 VDC
690 32-char. LCD Keypad
Remote Link'" Programming Software690FFireCommand"' 32-char. LCD System Link"' End -User Software
692F Fire Command"' Keypad
Alarm Monitoring"' Module7704-zone VFD Keypad Command Center"" Visual Command and
771 4-zone VFD Keypad with Control Module
internal relay
790 4-zone LCD Keypad
790F 4-zone LCD Fire Command SLR-835B Photoelectric Smoke
791 4-zone LCD with internal relay 521B/BXT Addressable Smoke, CleanMe
793 4-zone LCD with internal relay, 521LX/LXT Addressable Smoke/Heat,
Prox CleanMe
ePAD Easy -to -Use Internet Keypad 600 Series Heat Detectors
3045 Sentrol Panic Switch
5515G Sentrol Moisture Sensor
377 Trouble Annunciator Module requires 5501)
included with XRSSL) 5501 Sentrol Moisture Processor
860 Relay Module
865 Style Y/Z Notification Circuit
Module 801 Piezoelectric Mini -horn
866 Style W Notification Circuit 802 Mutitone Notification
Module Appliance
867 LX-Bus Notification Circuit 803 Horn Appliance
Module 806 Motor Bell
869 Style D Initiating Circuit Module 821 Sync/Non-Sync Strobe
893/A Dual Phone Line Module 822 Sync/Non-Sync Strobe Plate
995 Voice Module 823 Horn/Strobe Appliance
831 Single Sync Module
832 Dual Sync Module
502-12 Provides 2 Amps @ 12 VDC 850D Dual Action Fire Alarm Pull
502-80 80-hour Standby Charger Station
504-24 Provides 4 Amps @ 24 VDC
505-12 Provides 5 Amps @ 12 VDC
Primary Power 16.5 VAC 40VA transformer (Model 320)
Secondary Power 12 VDC 7.7 Ah battery (Model 367)
Auxiliary Output 500mA @ 12 VDC
Alarm Output 1.5 Amps @ 12 VDC (XR5FC)
Smoke Output 100mA @ 12 VDC (XR5FC)
Annunciator Outputs 50mA each (switched ground)
Dimensions 12.5" x 9.5" x 3.75"
800 641 4282
WWW.DMP.CO
850S Single Action Fire Alarm Pull
Station
300 Plug-in
305 Plug-in Relay Output
306 Tamper Harness
318 Dual Battery Harness
320 40VA Wire -in Transformer
321 40VA Plug-in Transformer
322 100VA Wire -in Transformer
349 Medium Enclosure
350 Large Enclosure - room for 4
batteries
350A Attack Resistant Enclosure
367 12 VDC 7.7 Ah battery
370RJ Lightning Suppressor with 2 RJ
Jacks
394 Direct Programming Cable
Secure -Corn Cellular
381 Cellular Handset
385 3dB Gain Cellular Antenna
430 Output Harness
708 Buss Extender Module
Underwriters Laboratories - S3598
UL 864
NFPA 72 Central Station
NFPA 72 Local Protective Signaling
NFPA 72 Remote Station Protective Signaling
California State Fire Marshal - 7165-1157:104
NYC MEA - 168-93-E
2500 N. PARTNERSHIP BLVD., SPRINGFIELD, MISSOURI 65803-8877
Model 377
Trouble
Main Backup MODEL XR5 Saencolteset Annunciator
1701
Push for One Second Module
3 Panel Reset1-1 Silence/Reset
Telephone. Cmnn0—
Header 0
Trouble Annunciator Header r,
no 0
Relay Sockets for Optimal
Direct connect to Form C -1V1., s on J31
unsvritched 120 VAC 60 Hz
O
J14 Bell Monitor Requires Model 305 Rebys
1 sM RED 11 1R air 71A-Z1A- Z:aa7:6- 72- 21 13 71- Z6 74 71 75- OSa j J12
7
431
1 2 3 s 6 7 9 9 0 1 2 1 4 s 1 17 I 9 Z 1 2 ycmrrVr+x-
Modd 320
virein transformer W Zone 5
if ; VAC 40VA Output Header
S S 3.3k Ohm ro. open CoNwra WpAs.
SUM U 30 VDU esf ve
m 4
tires Mt M 300 H
Secondary Power Supply
m W b
1.2 Amps max. charging current.
Zone 1 OSAp1A i output 2
s t s S S Output Header 311
Bell C"t
cad watte7 Plpe Two Form C (SPOT) Ouqus.
1.5 Amps @ 12 VDC
Eitls C—W
r N
lOk Ohm C-0L 331,Otm 331,ohm SmYrt! Snxle
Resist. dr.m dery
Mode1308`
Zone 4 3.3k Ohm
p Red
ay w.. I I Blade
Model 866 ,
aro
lass B (Style w) up
re
1()omA of ectrmt 15 available for Power
Nodflcatfon Orcuit Module 1,
4-wire spoke detectors from terminal 6. Supervision
37 MA 0 12 VDC eel ov ,
Relay
eai *ouvr
Oei 1%mk
Keypad Keypad
Model 692F Model 770
40rnA @ 8 to 16 VDC 100mA at 8 to 16 VDC
DODO
O O O O
Keypad 0 0 0 0
00 0 0
ell 690 CD CD CD O up to S00mA auxiliary p CD CD CD
p VDC cument0I2vOC6.n - OOOO
0000 Terminal? - 1&CharacterKeypads
10 Zone LED Keypads
32-Character Keypads
XR5FC System Configuration Diagram
The XR5 panels feature built-in 2-line
dialers, 500mA of auxiliary power, one Class
A (Style D) zone for sprinkler supervision,
four Class B (Style A) smoke detector zones,
12 or 24 VDC input, two Form C outputs,
four annunciator outputs, and a 4-wire bus
for remote LED or LCD annunciators.
Both panels also provide outstanding
software features such as one-man walk
test, passcode protected operation, cross -
zoning, fire verify and fire retard zone
programming, built-in programmer and
diagnostics, and remote upload/download
capability. There's also a Fire Drill feature
that allows an authorized user to sound just
the system's bells for evacuation exercises.
The following sections highlight the unique
features of the XRSFC and XRSSL fire
panels.
The XR5 panels each contain a built-in dual
phone line module with line supervision and
can communicate to one or two remote
receivers using Synchronous Data Link
Control (SDLC) digital dialer, Contact ID
CID), or 4-2 formats. You can also
selectively enable alarm, supervisory/
trouble, backup, and recall test reporting
to either of the two receivers.
The XR5 can send Alarm and Trouble reports
directly to a user's numeric pager. Pager
Direct is a must -have feature for anyone
needing instant updates on the status of
their system.
You can remote program the XR5 panels
using Remote Link'"' programming software
from DMP to load programs into new
accounts or make copies of existing
programs. You can also upload the 16 event
memory for diagnostic purposes.
The XR5 panels also contain an internal
English text Programmer that allows
installers and service technicians to easily
program and test the panels from an
alphanumeric keypad connected to the
remote annunciator bus.
For system annunciation, you can select
from several keypad styles to meet a
variety of fire system requirements. The
Model 692F LED keypad provides individual
alarm and trouble LEDs as well as power,
system trouble, and silenced LEDs along
with a full function, backlit keyboard. You
can also choose from 770, 690F, or 790F
series alphanumeric keypads. Both LED and
alphanumeric keypads meet all
requirements for local system operation.
For slave communicator applications, an
enclosure door mounted Model 377 Trouble
Annunciator Module provides Trouble and
System OK LEDs with audible alert and a
Silence button for acknowledging trouble
conditions. This module is included with the
XRSSL.
You can now conduct one-man tests of the
system and all connected devices using the
Walk Test feature. A fire technician simply
enters an access code into the keypad and
the XR5 panels automatically enter the test
mode. Each time a zone is tripped during
the test, the bell rings for two seconds and
a Sensor Reset is automatically performed
to reset any latched detectors. When the
test is completed, the results are displayed
at the keypad and can be sent to the
central station.
The built-in false alarm reduction features
include Cross -Zoning, Fire Verification, Fire
Retard, and CleanMeTm reporting. Cross -
zoning allows multiple zones to report
alarms only when two or more are tripped.
Should just one zone trip, a zone fault
report is sent to the central station.
Fire Verification provides a 120 second
window during which a smoke detector can
trip, be automatically reset, and then must
trip a second time before an alarm is
indicated. A single trip on the zone sends
just a zone fault report to the central
station.
Fire Retard allows a programmable time of
up to 250 seconds for waterflow detection.
This eliminates the need for additional
mechanical delays at the flowswitch.
The XR5 panels operate on either 16 VAC
from a wire -in transformer or 24 VDC from
a main Fire Alarm Control Panel (FACP).
This allows the panels to be used as stand
alone communicators or FACPs. When
powered from the 24 VDC input of a larger
FACP, the panels can operate as slave
communicators with 12 VDC auxiliary
output capability.
Four open collector annunciator outputs
and two optional Form C dry contact relays
are provided on the XR5 panels for a variety
of remote control and annunciation
applications.
E S L
P R O D U C T I N FORMATION B U L L E T 1 N
CleanMeTM remote maintenance
reporting reduces false alarms
Smart dual fixed/rate of rise heats
work with photo chamber to catch
fires faster
Built-in drift compensation reduces
false alarms
Field replaceable optical chamber
makes servicing a snap
Small, low profile design blends in
with any environment
CleanMe"'
COMPATIBLE
For a current list of CleanMe
compatible control panels, go to
www.sentrol.cont/products/esi
and click on the CleanMe logo.
521 SERIES
Low Profile,
Self -Diagnostic, Two -
Wire, Photoelectric
Smoke Detector
with CleanMe TM
UL Model numbers: 52113, 521 BXT, 521 C RXT
ULC Model numbers: 5288, 528BXT
Q,' California State Fire Marshal Approved
LISTED
The ESL 521 Series self -diagnostic, two -wire
smoke detectors are the industry's first conventional
direct -wire smoke detectors with analog features such
as remote maintenance/trouble reporting (CleanMeTM'),
drift compensation, and multi -criteria detection.
The 521 Series continually monitor their own sensi-
tivity and operational status, and provide a visual and
remote trouble condition if they drift out of the sensitiv-
ity range or fail internal diagnostics. This meets NFPA
72 field sensitivity testing requirements without the
need for external meters. The 521 has a unique feature
enabling it to send a signal (CleanMe) to the ESL 505
module (sold separately) when it has drifted outside of
its UL Listed sensitivity range or has failed its internal
diagnostics test. The 505 is an interface module that
will signal any panel via relays when the 521 is dirty.
Several control panels have the CleanMe software built
in, eliminating the need for the 505 module. When
CleanMe is not desired, simply leave the switch on the
521 off and it will work as a normal two wire detector.
CleanMe allows the installer time to schedule a service
call and avoid a false alarm.
Time between cleaning detectors is dramatically
increased because of the 521's built-in drift compensa-
tion. This feature, usually only available in analog
systems, allows the detector to automatically adjust its
sensitivity over time as it becomes dirty, increasing dust
life.
And when the 521 has told you that cleaning is
necessary, it's literally a snap with ESL's patented field
replaceable optical chamber.
continued
521 Series ESL Photoelectric Smoke Detectors
The multi -criteria model 521XT photoelectric smoke
detector/fixed rate of rise heat detector includes fast
response algorithms for a quick response to both flaming
and smoldering fires. Fast response algorithms allow the
heat detectors to work intelligently together with the photo-
electric smoke detector. As soon as the heat sensor detects
a rapid rise in temperature, the sensitivity of the photoelec-
tric sensor increases allowing it to detect smaller particles of
combustion faster.
Architectural and Engineering Specifications
The ESL 521 Series photoelectric smoke detector is a low -
profile, self -diagnostic , two -wire detector that monitors its
own sensitivity and operational status. This detector meets
NFPA 72 field sensitivity requirements without the need for
external meters. Built-in drift compensation automatically
adjusts the sensitivity as the detector gets dirty. Normal
sensing occurs every 9 seconds. This rate doubles when a
signal exceeding the alarm threshold value is sensed. Two
additional successive signals above the threshold level will
initiate an alarm.
See installation instructions for information about correct
installation and maintenance.
The proprietary optical sensing chamber is field replaceable,
allowing quick and easy cleaning and maintenance.
Dimensions:
2" (5cm) -- - -- 5" (12c
Specifications:
Product Data
Voltage..... Dip switch 1 "on" 6.5 — 33 VDC, polarity sensitive
Dip switch 1 "off" 8.5 — 33 VDC, polarity sensitive
Maximum ripple (pk to pk).................................... 10% (V
P)
Typical average standby current (24V) ......................... 761JA
Typical alarm current (24V) ................ up to 60mA max, if not
limited by control panel
Alarm Contacts .........................500mA @ 36 VDC (resistive)
Aux. Relay contacts ............ 2A @ 30 VDC, 1 A @ 120 VAC
Sensitivity — photoelectric .................. 3.1 % + 0.50 — 1.00%
Operating temperature ............... 32'F to 100'F (0' to 37'C)
Operating humidity range ............ 0 to 95% Non -condensing
RFI Immunity ......................... 20 V/m minimum; 0-1000MHz
Color .................................................... White head and base
Field wiring size ......................................... :......... 12-24 AWG
Detector packaging ............................10 detectors per carton
Heat detector specifications .. Rate of rise — 15`F/min and >
105°F (8.3"C/min and > 40.6°C)
Fixed — 135'F (57°C)
UL two -wire compatibility identifier.... Dip switch 1 'on" S09A
Dip switch 1 "offS10A, S11A Drift
compensation adjustment ........................... 1.0%/ft. max Detector
head dimensions ...................... 5" (12 cm) diameter 2" (
5 cm) height Mounting
dimensions ..................... 4.75" (12.5 cm) diameter; 0.
3" (0.8 cm) height Reset
time.................................................1 second minimum Listings........................................................
UL, ULC, CSFM Model
No. Description 521
B 2-wire, photoelectric, 6-24 VDC, UL listed 521
BXT 2-wire, photoelectric, 6-24 VDC, multi -criteria algorithms, fixed/rate of rise heat, UL listed 521
B-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with CleanMeM not individually boxed 521
BXT-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with fixed/rate of rise smart dual heat and CleanMe
not individually boxed 521CRXT
2-wire, photoelectric, 12-24 VDC, aux. relay, multi -criteria algorithms, fixed/rate of rise heat, UL listed 528B
2-wire, photoelectric, 6-24 VDC, ULC listed 528BXT
2-wire, photoelectric, 6-24 VDC, multi -criteria algorithms, fixed/rate of rise heat, ULC listed Accessories
505
Module that interprets the 521's CleanMe signal for panel and can convert 2-wire 521 Series to 4-wire inputs
on panel 401
Test magnet in plastic shell for pole mounting SM-
200 Smoke! in a CanQ4 (canned smoke) for functional testing of smoke detectors 211
Replacement optical chambers (set of 10) Vc
1998 Sentrol, Inc. Certain of the items in the Product Information Bulletin are protected under one or more of the following patents: 5,546,074; 5,708,414; 5,
798,701; 5,821,666. SENTROL
Sentrol reserves the right 12345
SW Leveton Dr., Tualatin, OR 97062 to change specifications without
notice. Tel.:
503.692.4052 Fax: 503.691.7566 ESL
Pd http:/lwww.sentrol.com ®1999 Sentrol U.S. & Canada:
800.547.2556 Technical Service: 800.
648.7424 A PRODUCT OF
SENTROL FaxBack: 1.800.483.2495 E-3753-FLG25K-0399