HomeMy WebLinkAbout114 Wilson Bay Ctc� l CITY.OF SANFORD PERMIT APPLICATION RECEI Permit #: r Ot Rif Date: V VEV CD Job Address: 1 i 4 W;; Ls7w 6p4 (A ZQOc Description of Work: �il/GYLr Er 17 Stvhn�slivCs►ta�L til//%7! /c�✓6 U 0 Historic District: Zoning: Value of Work: $ 5A. 7 r1 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Mteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel M _.7©'-5113 ' otbo� Owners Name & Address: em) -� �)Ireb�-�1e Contractor Name & Address: fil 6>0 I Q.0pJp, g(s� .D Phone & Fa( 461) o `(466 Bonding Company - Address: Mortgage Lender: . Address: Architect/Engineer: Address: (Attach Proof of Ownership & al Description) K nn c-+ 7(i y W i, hon 0 AAF. 0 - Phone: State License Number: Person: Phone: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptanceof ermit is verification th t Ii the owner of the property of the irem to ort" a ren La 7 Signature of Owner/Age Date Signature o ontractor/A ent Date !Eil m wltcasl " liS Sf/7i/�i0n/S tl1I LOM9 Lcnt'- Namei—A Print Contractor/Agent's Name 2°�7". Notary Public State of Floridas Alan Hale Ir N"iS0%ft9k fjlgp03645 Date Signature o Notes to of Public State of Mrida �'EExpires 09/19/2009 :° Frederick Alan Hale Jr My Commission DD473645 n° Expires 0911912009 , Owner/Agent is Personally Kngwn 3,9 e�{qr Contractor/ _Produced IDS 1f17Y /i,(G13 _ Produced ID APPLICATION APPROVED BY: Bldg: Z 6vutilities: FD: (Initial & Date) (Initial & Date (Initial & Date) (Initial & Date) Special Conditions: $3�5CP POWER OF ATTORNEY I hereby name and appoint `�� w � to be my lawful attorney in fact to act for me and apply to the Sc p k uildin Department pp y r for a W` permit for work to be performed at a location described as: Lot: Subdivision (Owner of Property and Address) and to sign my name—and,-do all things necessary to this appointment. [/ Richard H. Wemple CPCO25540 The foregoing instrument was acknowledged before me this Day of , 2006 by Richard H. Wemple Who is personally known to me/who produced as identification and who did not take oath. State of Florida County of Seminole Notary Public, Seminole County, Florida p` Tiffani Lynn Mavrakis My Commission DD263157. Vor r,,d° Expires October 29, 2007 POWER OF ATTORNEY I hereby name and appoint "M p`� 7 to be my lawful attorney in fact to act for me and apply to the SQ ,n-Vny- & Building Department for a SW 7\ '�, y o o \ permit for work to be performed at a location described as: Lot: Subdivision � (Owner of Property and Address) and to sign my name and do all things necess4ry to this appointment. Michael Calhoun EC0002325 460 N. Milwee St., Longwood, FL 32750 (407)260-5410 (407)312-5410 The foregoing instrument was acknowledged before me this -a0-N-\ Day of (` \ , 2006 by Michael Calhoun Who is personally known to me/who produced identification and who did not take oath. State of Florida County of Seminole as Notary Public, Seminole County, Florida ..ra' a TiHani Lynn Mavrakis My Commission DD263157 w n•V Expires October 29, 2007 v �.......... This Instrument Prepared By: Name: 51EVF lO&W Address: 801 EYRIE DRIVE OVIEDO, FLORIDA 32765 SUITE 100 Permit No. Tax Folio No. _—® - - NOTICE OF COMMENCEMENT STATE OF FLORIDA COUNTY OF 'THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of prQyerty: (legal description of property, and street address if available) Lotuz 2. General description of improvement: INSTALLING GUNITE SWIMMING POOL WITH CONCRETE DECKING AROUND POOL. 3. Owner information: a. Name and address: C3r1t�tC�tti�i, l --i._ b. Interest in property: c. Name and address of fee simple titleholder (if other than owner): 4. Contractor: a. Name and address: ATLAS POOLS OF CENTRAL FLORIDA, INC. 801 EYRIE DRIVE SUITE 100 b. Phone number: 407-366-4600 OVIEDO, FLORIDA 32765 c. Fax number (optional, if service by fax is acceptable): 5. Surety: NOT APPLICABLE a. Name and address: b. Amount of bond $ c. Phone number: d. Fax number (optional, if service by fax is acceptable): 6. Lender: NOT APPLICABLE a. Name and address: b. Phone number: c. Fax number (optional, if service by fax is acceptable): Itill 11 ti11t VIaIN Mato VAM WM 111144111 SENINLO-E' LIMMI, W 066S F'r3 01-49; Upgi CLERK" S :4R,10310)11) 1'f 311,/11) La4// -'18 iA20 t; S id163i�'+•R ti9 1;ED:tE1ll N6 FEJI: a 10.00 J4090l 1W t 11L%Wea 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be serve As provided in section 713.12(i)(a)7., Florida Statutes: NOT APPLICABLE a. Name and address: b. Phone number: c. Fax number (optional, if service by fax is acceptable): M* t 14 1 E (,1,` a 8. In addition to himself, Owner designates the following person(s) to receive a copy of the� ����� Provided in Section 713.13(1)(b), Florida Statutes: NOT APPLICABLE a. Name and address: SEMI 0 Y, FLORIDA b. Phone number: c. Fax number (optional, if service by fax is acceptable): CLERK 9. Expiration date of notice of commencement ( the expiration date is 1 year from the date of recordilWnALPs a6 Different date is specified) ONE YEAR. Sworn to and subsgribed before me by who is personally known to me or produced S.P-Vcj-�f -�Z3-bas identification, and who did /V97— take an oath, this Owners Signature "� F:� rft+"N t Printed Name I Owners NameyaLpiit/ES��`= f'G'N5 day of 20OU Owners address 114 i�oyt C --i, \ `� I Ft._ -39711 d Signature of Notary: Driver License # ' 6-7l —d 63- Printed name of Notary:: NI c4 Commission No. / Expiration: 1 Z1;�?` a� Seal: a;, STEPHEN PATRICK DOLAN MY COMMISSION # DD502197 ALL INFO I;n WT BE WWP OR Pt TED LEGIBLY TO COMPLY WITH RECORDING REQUIREMENTS (407) 398-0153 Florida Notary Servico.com JOB NAME 5 i MNAor S JOB # 06 - LOCATION MAP The �teb,;K(N `\ W Homeowners Responsibilities: Prior to start of construction all landscaping, sprinkler systems, and any unforeseen Stumps in areas of access and pool construction' must be removed by homeowner ... If pool is to have a gas heater of any type, arrange for delivery of storage tank and or hookup is the responsibility and expense of the homeowner ... as is any resodding or landscaping. Z-, P�oo �� ppia Ri h bob LF i dK_ LTJ i 1 3 iia X ,/ -� y t S� U \ L Ent/ + J t-tCl. Z' After the construction department completes an inspection and ATLAS POOLS OF CENTRAL FLORIDA, INC. assesses the site, some changes may be required. (i.e. Retaining 801 EYRIE DRIVE, Suite 100, OVIEDO, FL 32765 wall due to slope of yard, house setbacks, and utility'easements).. (407) 273-4600 = (407) 366-4600 = Fax (407) 366-5023 Pool contractlprice will then be adjusted accordingly if any additional POOLS Web Site: http✓/www.atiaspoolsofcentralfi.com CPCO25540 • CPCO56942 is required. Homeowner/home builder is responsible for having deck °`C` LFLORIDA, W ' treated for termite protection after deck has been formed. MAX. WIDTH:) ft. MAX. L NGTH: 3b ft. DEPTH_ to POOL: SURFACE AREA (- U Sqft. PERIMETER: g Linft. SPA: SURFACE AREA $ Sqft. PERIMETER: I Linft. PREP WORK [ q� DECKING EXCAVATION:Type i�OPMP t TYPE: AC- f—Sqft. I Ir. REMOVAL: DIRT: S)RUAt1--1lt OTHER: A;. Sqft. Sao. STUMPS #-CL Size TOP EXISTING: x.z _S ft.` — �.a,� ��-- CONCRETE:�_Sgft. DECK -O -DRAIN: Linft. to to 0.� TRASH: # P+3 Loads FOOTERS (Normal ree�n Linft. �� x 4- 3� f39;ki � j FENCE: Removed by t� k cif � Thicken Edge: 6" + Linft. * la Nbiyr�i,. + 1 Replaced by "rif\P(Ju0 e — I GRADING: When _LL #hrs �( 12" (] Linft. S Lif.CtW"k18" Linft. A111 STRUCTURAL WORK 24" ( � Linft. CANTILEVER (Total): Linft. "Angle of Repo" EngineeringMID Linft. OTHER EDGE: I- cr 8 Bond Beam (Stone /Brick) KI Linft. t� PAS.ft Steps/Swimout over 30 -ft [__Linft. Type tlb>t� Linft. RAISED BEAMS 6" I' Linft. BANDING: Yes N ✓ if 12" D Linft. STEP RISERS (Regular) Linft. 18" o Linft. (Cantilever/tile) Linft. 4" Linft. BE AREA Shallo Dep No EQUIPMENT & ACCESSORIES 3, TILE: Waterli x 6' ) � FILTER. SIZE ' - EDGE TILE es X No— MAIN PUMP: HP INTERIOR: A iL a Addt'I PUMP hp COLOR: T Is LIGHTS: # I pe -7 {e, Q- CHLORINATOR wk / THERAPY SPA no CLEANER: A) INSIDE ✓ OUTSIDE _ Size of 0 Sqft. HEAT PUMP '(8 -Ton) Yes (o - I • !. Includes: Bench, & # Jets SOLAR # PANELS ntraT (z�tE # WATER FEATURES: tL— DAM WALL-� ft. Spillway— " Wide LIGHT: Type � . C� SAFETY FENCES: LiD11. Pool/Spa Control NO GATE,�L DIRT PAVERS_ HEATER: at as ro Total Gallonage: �J SODG `y, 6 i BTUs `d j L� MISC ELEC. RUN (Meter to Equip) Linft. PLUMBING (Equip to Pool) Linft. BUYERleas Initial W Approve the Above Specifications: Approve the Equipment Location: S mF oil, ; C Prepared By: t Exclusively For: ho Name: � � � yj $ a p�poc�\Q 'S 1 md4.t f' s, M IN 1� � Address: 3 �TCity: ���°. Zip_ _ e a Home Phone. _ ork: Cell _ - l Permit to be secured from: Lot: Block: —Subdivision: qtr I U VX' e1eJs Plat Book: �� Pages:1� , PR of �*\ ZI Customers Signature:'�!`' �' Date:'61 t 04/ SCALE: 1/8 = 1' O" SCREEN ENCLOSURE: Size + x $ STYLE COLOR I WALL HGT + DOORS INS RTS PAN ROOF 21TEJ�OOF F SIZE 4 FAN BEAMS a 8 X a VACUUM LINE (OPTIONAL) SKIMMER W/ SAFETY VACUUM FITTING 1'/"pJ ` POOL PUM MIN 6" MAX 12• ANTIVORTEX COVER VE II L2" \ 2'fd VACUUM LINE (OPTIONAL) W/ SAFETY VACUUM FITTING 1WO VE II SWIMMING POOL SECTION ALTERNATE_A• SUCTION INLETS (MAIN DRAINS) SKIMMER �f MIJ6' IT MAEAN0C 2.0°a SUCTION INLETS SWIMMING POOL (MAIN DRAINS) SECTION RESIDENTIAL SWIMMING POOL, SPA, AND WADING POOLS DUAL SUCTION INLET SYSTEM & VACUUM RELIEF SYSTEMS IN ACCORDANCE WITH SECTION 424.2.6.6 FLORIDA BUILDING CODE- BUILDING 2004 AND SECTION R4101.6.6 FLORIDA BUILDING CODE- RESIDENTIAL 2004 ANTIVORTEX COVER PA PUM VE II 2.0 SUCTION INLETS (MAIN DRAINS) SPA SECTION ALTER_ N- ATE "A° SKIMMER ANTIVORTEX COVER i PA PUM C t 1 Y. VE II I 2Yd SUCTION INLET (MAIN DRAIN) SPA SECTION ALTERNATE •B' VACUUM LINE ALTERB- (OPTIONAL) W/ SAFETY VACUUM FITTING SKIMMER Al AN APPROVED VACUUM RELEASE SYSTEM SUCH AS THE VAC- SVRS SYSTEM IS AN ALTERNATIVE VACUUM RELIEF ;�•:MINJ6- OOL PUM DEVICE, INSTEAD OF EITHER OF THE Tlll<O SYSTEMS SH01l1/N. MAX 1 ,/�••/2' VE II 2-� J _� SUCTION INLET ATTACH PLACKARD WHICH STATES (MAIN DRAIN) THAT VENT IS A SWIMMING POOL SAFETY DEVICE AND SHOULD NOT SWIMMING POOL BE TAMPERED WITH. secTloN ALTER�C. ALTERNATE SUCTION INLET SYSTEM MAY INCLUDE 1 ON THE BOTTOM AND ONE ON _ THE VERTICAL WALL OR ONE EACH ON TWO 2) SEPARATE VERTICLE WALLS VENT COVER MAY BE GUTTER DRAIN SUCH (1) VERTICAL TOLERANCE - IS + T (1) WATER— LEVEL MARK TO PUMP VENTED COVER SUCH AS SKIMMER COVER W! COLLAR VENT AND EXTENSION SET CAP \ FUS DECK DECK TO PUMP \ 6" 0 PVC SLEEVE EXTENDED FROM COVER COLLAR VENT IN DECK CAP 6' EXTENSION r COUPLE ,7 /, DECK VENT TO ATMOSPHERE SO VENT AS 10 D MODEL SP -10i 9 TO PUMP 9 WILL NOT BE BLOCKED BY DEBRIS, INSECT INFESTATION, OR MICROBIOLOGICAL CONTAMINATION 2 - 90° ELBOWS (COVER MUST COMPLY WITH - OFF DECK ° ANSI/ASME Al 12A 9.8 M) 1 'I" 0 VENT PIPE 3'-0' MINIMUM r --S E,CTION VfEW E ALTERN SEATE \ 2.0 2"T \ 4 INSTALLATION OPT1aNS I 2"� SUCTION INLET 12" MIN. 1 /" 0 (MAIN DRAIN) SUCTION INLET (MAIN DRAIN) � MAXIMUM DISTANCE 2"0 ALL VENT 3UGGE57ED H� GSE TO VENT TEE MAY 2 3 2009 CONNECTION = 1 " — PIPING - 1 Y2'0_DETAIL ATMOSPHERIC VENT PIPE LENGTH 2°0 MINIMUM = 16" MAXIMUM = 30" DRAWING TO SUPPLEMENT ALLSUCTION CONTRACTOR'S SPECIFICATION TO PUMP PIPING= 2"0 DRAWING ON FILE R H. EP DS(?h MAXIMUM SUCTION PIPE VELOCITYTHE MAXIMUM VACUUM WITH ONE �- P. NO SIX (6) FPS OR 59 GPM SUMP PLUGGED AND TO RELEASE 171 1pe INLET SYSTEM A BODY ENTRAPMENT ON THE OTHER [:DUA::LSUCTION ASPHERIC VENT SYSTEM SUMP MERCURYLL NOTINICN 3 SECONDSCEED 4.5 HES� ( a57-4133 FAX (4177) ®57-41 M , P. F_ -DECK- WATER LEVEL 4' 8-/,- > _ I-�►3' MIN--.'•� LLI CL TYPICAL POOL AND SPA INSTALLATION SUCTION FLOW FOR RESIDENTIAL POOL= 8 FPS SUCTION FLOW FOR RESIDENTIAL SPA = 6 FPS CONTRACTOR MAY SUCTION PIPE SIZE TO MEETTHESE REQUIREMENTS MAX "L' TO MAIN 1'r4' qq• -19• ' -"-a eLnuvv ELBOW r 1 z a• ZT 31' 2 'f,' 3• T L3' 4' 3" 4• 8' 118• 55' 4' S 12' 5' 156• 72• 5" IT 1 14' PIPE LENGTH TO VE II = "L" - ELBOW FRICTION LOSS EXAMPLE THE MAXIMUM PHYSICAL PIPE LENGTH FROM MAIN DRAIN TO VELI IF USE Y 0 PIPE W/ 2-90" ELBOWS AT 6 FPS -IS 54'- 12' = 42• [IVACCUUM SUCTION ELIMINATOR — VE 11 VE II IS REQUIRED FOR EACH PUMP PLUMBED TO A MAIN DRAIN ATLAS POOLS OF CENTRAL FLORIDA, INC 801 Eyrie Dr., Oviedo TEL — (407) 366-4600 , NOT TO SCALE' 6Jr D BY- VHV 1. FOR POOL PLAN, SIZE, DECK SPECIAL DETAILS SEE CONTRACTOR'S POOL PLAN. 2 POOL WALLS SHALL BE 5" THICK AND FLOORS SHALL BE 6" THICK AND SHALL BE PNEUMATICALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF. 3,000 PSI IN 28 DAYS. CONCRETE DECK SHALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318. 3. ALL POOL CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING CODE BUILDING 2004, FLORIDA BUILDING CODE RESIDENTIAL 2004, ANSI NATIONAL STANDARD -5 FOR RESIDENTIAL INGROUND SWIMMING POOLS, AND ANSUNSPI NATIONAL STANDARD -3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS. 4. ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. a ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40, REINFORCING SHALL BE # 3 BARS AT 12" O.C. EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO 6'. OVER 6' USE #3 BARS AT 6" ON CENTER EACH WAY IN THE AREA OVER 6'. IF CONCRETE IS CAST AGAINST BARE EARTH WITHOUT A SEPARATION BARRIER, MINIMUM COVER SHALL BE 3". WITH A BARRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER, SHALL BE 1 A". 6. ALL METALLIC POOL FITTINGS WITHIN 5 FEET OF THE INSIDE WALL AND DECK REINFORCING STEEL TO BE BONDED TO THE POOL REINFORCING STEEL WITH #8 AWG COPPER WIRE. #8 AWG COPPER WIRE TO BE RUN INTERNALLY AND EXTERNALLY WITH THE NEC APPROVED PVC LIGHT CONDUIT FROM THE LIGHT NICHE TO THE JUNCTION BOX. COMPLETION OF POOL GROUNDING TO PANEL GROUND BY ELECTRICIAN. 7. POOL OR PAT10 SHALL BEAR ONLY ON ROCK OR CLEAN SAND, WHICH SHALL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY, ANY UNSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN IT'S ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. 8. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS IF REQUIRED. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES: 9. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. 10. CONTRACTOR SHALL DETERMINE LOCATION OF ALL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIONS AN ORDINANCES. 1L CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUND CONSTRUCTION AREA TO PREVENT UNAUTHORIZED ENTRY INTO AREA. L2 IF A WATER SUPPLY IS PROVIDED, A MINIMUM 3" ATMOSPHERIC BREAK WILL BE PROVIDED. 19. ALL STRUCTURAL FILTRATION, AND ELECTRICAL DETAILS OUTLINED IN THESE DRAWINGS ALSO RELATE TO SPA CONSTRUCTION. 14. ALL POOL AND SPA HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW THE HEATER TO BE SHUT OFF WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. 15. SPAS AND HEATED POOLS SHALL HAVE A COVER DESIGNED TO MINIMIZE HEAT LOSS UNLESS 70% OF THE ENERGY FOR HEATING IS DERIVED FROM NON-DEPLETABLE ON-SITE RECOVERY SOURCES. 16 THERE SHALL BE ADD SAFETY GLAZING IN DOORS AND WALLS OF ENCLOSURES FOR HOT TUBS, AND OTHER SUCH FACILITIES WHERE SUCH GLAZING IS LOCATED 36" OR LESS FROM A STANDING OR WALKING SURFACE WITHIN THE ENCLOSED AREA OR LESS THAT 60" ABOVE THE FLOOR OR WALKING SURFACE. T7. WARNING! TO EMPTY THE POOL FOR ANY REASON, THE HYDROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. C WATER LINE LIGHT 5' 6" TILE- -STEPS 8' MAXIMUM RISER = 12' MAXIMUM TREAD = 10' (240 SO. IN.) DUAL SUCTION OUTLET (OPTIONAL) SET INTO CENTER OF STEEL GRID AT POOL DEEPEST POINT W/ 3' SEPARATION LONGfTUDINAL POOL SECTION BRICK COPIN*WATER 6'X6' TILELAN) ES LINE L -6-X6' GLASS BLOCKS MOUNTED IN 2500 PSI CEMENT (IF SPECIFIED) #3 AT 12" O.C. EA WAY RAISED SPA DETAIL SOIL (NO VOIDS) TYPICAL SWIMOUT DETAIL, THE FOLLOWING TABLE PROVIDES MAXIMUM FLOW THROUGH PVC PIPE WITHOUT EXCEEDING THE MAXIMUM STANDARDS FOR VELOCITY (FT/SEC) 2'85 GPM 105 GPM 2 HP 2 'A 125 GPM 190 GPM 2 1/2 HP PUMP SIZE BASED ON A TOTAL DYNAMIC HEAD (IDH) OF 50' AND FOR ESTIMATE ONLY. ACTUAL PUMP 512E WALL VARY DEPENDING ON THE PUMP SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE SPECIFIC POOL NEEDS SURFACE SKIMMER ADDITIONAL X13 gffiT REBAR REOD AT SKIMMER OPENING WALL SEC11ON AT SKIMMER 5' VARIES — SEE PLAN DISTANCE THERAPY LESS THAN 1 ON 1 +1 #3 AT 12' 18' SEAT O.C. EA. WAY 4' , RETURN (1ST SPECIFIED) 6 1" GUNITE REBOUND 2-8" 0 ANTI—VORTEX DRAINS SEPARATED BY 3' SPA SECTION , 1 #3 BAR CONT. W/ 5' WALL—W/ 8'X8' BOND BEAM USE 2 #3 BARS CONT. 18" MIN. TO TOP OF LENS— MARBLE PLASTER FINISH 4" NOW "FIBER MESH- CONCRETE DECK W/ SUP RESISTANT TOPPING ON COMPACTED GROUND W/ ALL ORGANIC MATERIAL REMOVED (OPTIONAL) 4' MIN. JUNCTION BOX B" MIN.it (BY OTHERS) TO TRANSFORMER (8Y OTHERS) —U:L. APPROVED 120 VAC/30OW POOL LIGHT W/ REFER TO ATTACHED DRAWING GFI OR 12V/30OW POOL LIGHT W/ LOW WATER FOR DATA REGARDING DUAL CUT OFF IN U.L. APPROVED GREY PLASTIC SUCTION OUTLET SYSTEM AND FORMING SHELL W 8 VACUUM RELIEF SYSTEM / # BOND PER N.E.C. 0 AWG COPPER WIRE TIMECLOCK TO PANEL SERMC SPST JCT. BOX TOGGLE 5 MIN. r SWITCH 8' MIN. W.P. DISC 1 PUMP POOL DECK 12 V TRANS 3 #12 IN '�" COND 12 V/300 W W/ LOW ALL ELECTRICAL WATER CUT—OFF SHALL CONFORM OR 120 V.A.C. W/ GFI W/ ART. 680 PER N.E.C. N.E.C. 2002 ELECTRICAL DIAGRAM �W/ 8"X8" BOND BEAM 1SE 2 #3 BARS CONT. MIN. 1 Ye" COVER OVER ALL BARS SEE NOTE J5 EXISTING STRUCTURE 6' THICK WALL #3 BARS AT 6' G.C. EACH WAY STEELTEX FORM MARBLE PLASTER FINISH #3 BARS 12' O.C. EACH WAY STEELTEX FORM (OPTIONAL) POOL STRUCTURAL DETAILS j 1 � 5 6" TILE 1 BAR 5 � � 5* WALL/ BRICK (1 ROW) DECK OVERPOUR ALTERNATE BEAM FINISH DETAL, PLAN EXPIRES ONE YEAR FROM THE SIGNATURE DATE OR THE EFFECTIVE DATE OF A MAJOR FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER THE CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6' ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED AT 6' THICKNESS. THE STEEL MAT AND SHELL WALL SHALL BE EXTENDED ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED DISTANCE AS DETERMINED BY THE 1 ON 1 + 1 METHOD. TYPICAL WALL AND FLOOR WITHIN ANGLE OF PE -POSE MAY 2 3_-- CATE GO .D N H. S !EPADSON, P.E. FL. P E. NO 1 333 17 7 OLFS DRI E WIN E PAR 3 762 PH011 : (40/) 055'-41.33 FAX: (407) 657-4133 FILTER SYSTEU 1. MAIN DRAIN UNE 2. SKIMMER LINE 3. WASTE LINE 4, RETURN UNE 5. PRESSURE CLEANING UNE (OPTIONAL) 1 A. HAIR & LINT STRAINER B. RECIRCULATOR PUMP C'FILTER D. IN—UNE CHLORINATOR (OPTIONAL) E. HEATER (OPTIONAL) VALVE F. ANTI ENTRAPMENT SYSTEM 28' MIN. PER MANUFACTURER SPEC. LADDER TO BE CROSS BRACED PER MANUFACTURER'S SPEC ALL LADDER TREADS SHALL HAVE SUP RESISTANT FINISH WEDGE ANCHOR AND ESCUTCHEON 3' MIN. 8' MAX. BETWEEN TREAD AND POOL WALL TYPICAL SWIMMING POOL LADDER SECTION ATLAS POOLS OF CENTRAL FLORIDA, INC 801 Eyrie Dr., Oviedo TEL - (407) 366-4600 RESIDENTIAL SWIMMING POOL MASTER SPECIFICATION DRAWING FOR NOT TO SCALE F A't":. - (.HS PLAT OF SURVEY DESCRIPTION: (AS FURNISHED) LOT 268, PRESERVE AT LAKE MONROE, UNIT 2 AS RECORDED IN PLAT BOOK 66, PAGES 10-11 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA 1" 30' GRAPHIC SCALE 0 15 30 NOTE: THE FINISHED FLOOR ELEVATION OF THIS STRUCTURE MEETS OR EXCEEDS THE THE REQUIREMENTS SET FORTH IN THE CITY OF SANFORD CODE CHAPTER 6, SEC. 6-7(A). TRACT A STORMWATER MANAGEMENT AREA 5009' _ '-1 `' N19 -i2 41 E 14.2 FND 1/2" IR01 ROD AND CAP ILLEGIBLE (12/06/05) 2. z 0 LOT 269 u7 0 o �! 0 P 1111LO --------------- L.12., fid.- IMtl4W 1 fir r+n E4�. L! 40.0' TWO STORY CONCRETE BLOCK & WOOD FRAME RESIDENCE FINISH FLOOR w ELEVATION -16.33 m ct pl I �I = COVERED 11'0 5 ENTRY .3' M I i ;.1 I # I 20.7' u I n I I C6NC�RTE.;• • 1 1 I DRIVEWAY N I U � I (n `-J------------- 10' -----------10' DRAINAGE & UTILITY EASEMENT WALK IS ;1:. •.':":'..;`5. C\W;•`":;' 0.5' OFF .. S89'52 41 W N p 50.00, N 01V 'Ib PI m m-� 356.77----� ---- 4 N89 41 - - '52'"E CENTERLINE 0� -� RIGHT-OF-WAY WLSON BAY COURT vl 50' RIGHT-OF-WAY m NOTE: 1. ALL DIRECTIONS AND DISTANCES HAVE BEEN FIELD VERIFIED AND ANY INCONSISTENCIES HAVE BEEN NOTED ON THE SURVEY, IF ANY. 2. PROPERTY CORNERS SHOWN HEREON WERE SET/FOUND ON 12-06-05, UNLESS OTHERWISE SHOWN. 3. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 5. BUILDING TIES SHOWN HEREON ARE TO UNFINISHED FORMBOARD/FOUNDATION AND ARE NOT TO BE USED TO RECONSTRUCT THE BOUNDARY LINES. 1 HAVE EXAMINED THE F.I.R.M. COMMUNITY PANEL NO 120294 0035 E DATED 4/17/95 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE IN ZONE X. AREA OUTSIDE 100 YEAR FLOOD PLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A, AGENT FOR VERIFICATION. ELEVATIONS SHOWN HEREON ARE BASED ON SEMINOLE COUNTY VERTICAL CONTROL AS FURNISHED. BEARINGS SHOWN HEREON ARE B THE WESTERLY LINE OF LOT 268 FIELD DATE:) 05/26/05 SCALE: 1" = 30 FEET APPROVED BY: SJ JOB NO. ASM45521 DRAWN BY: -- REVISED: 'INAL 12-06-05 SJL FORMBOARD k3 06/30/05 CK FORMBOARD p2 06/24/05 JP PLOT PLAN 2/22/05 SDO .0T FIT 8/03/04 500 G:\ASM-15\ASM4552I.dw9, 12/13/2005 10:51:32 AM bL5' F 0 0- 05 r0 -a !P LOT 267 Ln 0 m 10" X 10" CONCRETE LIGHT POLE 294.26' 653.03' v PC LEGENDQ SET Tp6393 1(ON OD AND CAP — • — . — . — BUILDING SETBACK LINE Q FND NAIL AND DISC - CENTERLINE LB #68 (12/06/05) - - RIGHT OF WAY LINE FND 1/2" IRON ROD AND CAP EXISTING ELEVATION © LB 0393 (12/06/05) A/C AIR CONDITIONER 0 DENOTES DELTA ANGLE CONCRETE (P) PER PLAT PC DENOTES POINT OF CURVATURE C CHORD LENGTH PCC POINT OF COMPOUND CURVE C.B. CHORD BEARING PCP PERMANENT CONTROL POINT CBW CONCRETE BLOCK WALL PI DENOTES POINT OF INTERSEC71ON CNA CORNER NOT ACCESSIBLE PK PARKER KALON CP CONCRETE PAD POC POINT ON CURVE CS CONCRETE SLAB POL POINT ON LINE C/W CONCRETE WALK PRC DENOTES POINT OF REVERSE CURVATURE F.E.M.A.FEDERAL EMERGENCY MANAGEMENT AGENCY PRM PERMANENT REFERENCE MONUMENT FND FOUND PSM PROFESSIONAL SURVEYOR AND MAPPER ID IDENTIFICATION PT DENOTES POINT OF TANGENCY L ARC LENGTH R RADIUS LB LICENSED BUSINESS RP RADIUS POINT LSLICENSED SURVEYOR S/W SIDEWALK (M) MEASURED P TYPICAL OHU OVERHEAD UTILITY LINE UP UTILITY PAD AMERICAN SURVEYING & MAPPING CERTIFICATION OF AUTHORIZATION NUMBER LBM6393 1030 N. ORLANDO AVENUE, SUITE B WINTER PARK, FLORIDA 32789 (407) 426-7979 THIS 13 A DOUNDARY SURVEY NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. FOR E FIRM JAMES JAY JILES PSM #4997 DATE SEN.SCote flORIDAi NAW. 10 Permit # Residential SWiLMMing Pool, Spa and Hot Tub Safety Act (We) acknowledge that a new -swimming pool, spa or hot tub will be constructed or installed ort IN (,car j5mL44 3a 77( , and hereby affirm that one of the following (Please "nflftee Address) vnethbds will be used to meet the requirements of.Chapter 515, Florida Statutes. Tease initial the method(s) to be used.for your pool) The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of Florida Statute 515.29; The pool will be equipped with an approved safety pool cover that complies with ASTM F1346-91 .(Standard Performance Specifications for Safety covers for Swimming Pools, Spas and Hot Tubs); All doors and windows providing direct access from the home.to the pool will be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at 10 feet; All doors. providing direct access from the home to the pool will be equipped with self-closing, self -latching devices with release mechanisms placed no lower than 54" above the floor or deck; understand that not having one of the above installed at the time of final inspection, -or when the pool Is completed for contract purposes, will constitute a violation of Chapter 515, F.S. and will be considered as committing a misdemeanor of the second degree, punishable by -fines up to $500 andlor up to 60 days in jail as established in Chapter 775, F.S. i CONTRACTOR'S SIGNATURE( DATE 1 Gh��D CONTRACTOR'S NAME (PLEASE RINT) 'S SIGNATURE OWNER'S NAME (PL ASE PRINT) ATLAS POOLS OF CENTRAL FLORIDA, INC. 801 EXrie:Drive, Suite 100 •Oviedo, FL 32765 (407) 366-4600 • (407) 273-4600 • Fax (407) 366-5023 AGREEMENT h CPCO25540 1. PARTIES: A reement between ATLAS POOLS OF CENTRAL FLORIDA, INC, hereinafter called the Contractor, and �JY�iMC�'\S Hereinafter called the Owner 7' 2. AGREE ENT: The Contractor agrees to build a residential swimming pool on the premises described as follows: Address: A ISCn EON Nom; t c=C- 3@711 Legal Lr,+ R(A l[ lc cwt� 3. PRICEandTERMS: 1) Total Contract Price ` 1 'OE -k- VA C:k-,'^ b �J/� L ($ 51311 -1�S 3 ' 6 '' 11 ) payable as follows: (1) $ LI, oC 7. gy 10% payable upon signing of this instrument as a deposit. (2) $ 30% upon completion of dig and steel. (3) $r 30 % upon completion of the concrete shell. (4) $ (L++ 1 L 19 C 25% upon plumbing, extras, and after rough deck is poured. (5) $ 1 r lJ (If applicable) after fence or screen has been installed. (6) $ 0 (If applicable) after solar has been installed. (7) $ Ib • Cit� 5% balance of contract price, prior to initial chlorination of the pool but, in any event, prior to the utilization of the pool by the Owner. Extras are in addition to the contract price and shall be paid on installation. Progress payments and payments for extras are payments for completed work, and if not paid within 10 days from their due date they shall bear interest at the rate of 18% per annum until paid. 4. CONSTRUCTION SPECIFICATIONS: Contractor will install a swimming pool and appurtenant structures and equipment in accordance with the plot plan and these construction specifications. Contractor reserves the right to substitute like or similar material, equipment or fixtures. The plot plan is intended to be a representation of the pool to be built and is not intended to represent an "as built" drawing, because pool location, elevation of pool, location of decking and enclosures are subject to changes due to set -back requirements, locations of existing improvements, soil conditions and other conditions beyond the control of the contractor. All measurements in the contract and on the plot plan are approximate and the pool dimensions contained in the contract may vary from the "as built" measurements. Deviations up to 3 inches are acceptable. Therefore, the parties agree that it is impossible to ascertain actual damages in the event of deviation from specified pool dimensions. The parties agree to adjust the contract price of an amount calculated by multiplying the percentage reduction of surface area times one-half (1/2) of the total contract price for diminished water surface area, and $50.00 for each vertical inch of depth deficiency measured only at the main drain and shallowest portion of the pool as liquidated damages to owner resulting from said variations, if any. Depth is measured from the floor of the pool to the top of the water line tile. Any additional soil needed for decking or normal grading in excess of what is dug from the pool, is at the home owners expense. Any and all additions required by building department would be at owners expense. If a diving board or slide is installed, there is no liability assumed for injuries as a consequence of use or misuse of the diving board or slide. If a diving board or slide is installed later, there is no liability to the pool contractor and it shall cancel all warranties. EXISTING Sprinklers: Removal �� •t� Rerouting:Oc�nt+t Planting: Removal 1� 'rLC)ti:�r\Q� Resodding: tA0rA 0kx1iA P,C Fencing: Removal �ri��L:�r1L� Reinstalling:Rcm1eQ� -iyrlk ���,, POOLSHAPE ti� Underwater Light( i� L �� Pump`hklarf 1 Elevation Handrail �G Filter�i�k� Slii�u k0 1 n� Shallow Depth Skimmer i Chlorinator Greatest Depth Ce Main Drain Heater IV d Greatest Width J ( Returns 3 Auto Vac. System i� Ai31%�i�FZ Greatest Length 301 Interior Finish MptA k_ CO�OC S Deck I3'ri'A ptot Auto Timer Shallow end Steps Included Swim -Out Included Termite Treatment Pc1'Y\Q♦Za)1Q Vac. Head, Hose, Brush Included Pole and Test Kit Included / Safety Barrier ch06_�' (\,-2 ` c Screen BVLn� Z tL ! J� �111c A 4IL; Additional Work: 3 ;T. 3' x 1T conct�ec N.AL a l 5. BUYERS RIGHT TO CANCEL: The Contractor shall not be obligated to commence construction of this pool until three (3) days after the signing of this contract by the Owner. Since this contract may be construed as a Home Solicitation Sale, purchaser is hereby notified of his right to cancel under the Home Solicitation Sales Act. This is a Home Solicitation Sale. If you do not want the goods or services contracted for, you may cancel this agreement by mailing a notice to seller. This notice must indicate that you do not want the goods and services and must be postmarked by midnight of the third day after you signed this agreement. If you cancel this agreement, the seller may keep all or part of the cash down payment. 6. OFFER AND AGREEMENT: This Contract Shall be deemed an offer to ATLAS POOLS OF CENTRAL FLORIDA, INC., and shall be null and void unless accepted by a duly authorized officer of the Contractor within ten (10) days of the date and year noted the Owners' signatures. The Salesman has no authority to bind the Contractor. All agreements and understandings are contained in this contract and the Owner warrants that there are no agreements or understandings other than are set forth in this document. Acceptance of the terms of this contract by Contractor is to be communicated to the Owner by transmitting a copy of this contract to them showing acceptance by the sellers by the execution of a duly authorized officer of the Contractor or by commencing construction. NOTICE TO PURCHASER DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ IT OR IF IT CONTAINS ANY BLANK SPACES You are entitled to an exact copy of this contract that you have signed and hereby acknowledge that it was comp d and signed on the day of Presented by _ OWNE Salesman — _:�o NER � Accepted by ATLAS POOLS OF CENTRAL FLORIDA, INC. STREET ADDRESS i (`1 W 1S�n► C _ CITY, STATE & ZIP Pit- '+ Pi 17' PHONE NUMBER - NOTICE: SEE REVERSE SIDE FOR IMPORTANT WARRANTIES AND CONCLUSION OF CONTRACT. AP-SN01 12/14 Rwmer MBF 407-657-7414 10/25/2005 TUE 15;02 FAX 0001/001 ---' NOV 1 5 2005 PRESERVE AT TAKE MONROE HOMEOWNERS' ASSOCIATION, INC. AT.TERAVON APPLICATION OWNER'S NAME -AI L( Srq944M I l✓ S rnmafQ S DATE: ADDRESS: CT jLoT Z.u,6 PHONE: DESCRIBE IN DETAIL, TYFE OF ALTERATION AND MATERIALS TO BE USED: -AM- rbn-) of 11�1 X 1-30) 'RhL- LO/ S('P� 7' X yb� r�b6C EAY-L&SWEE - �� �� UTTC X s!jST& �1 �o Z G W L C a C TC- (TF MORE SPACE IS REQUIRED, PLEASE j Trrg A THANK YOB i j An application requesting approval for any alteration which occurs outside the exterior walls of the building and is, therefore, common area, MUST BE ACCOMPAINED $Y A SKETCH ON YOUR LLT SURVEY: INDICATING LOCATION SIZE TYPE, OF CONSTROCTION AND OTHER PERTINENT INFORMATION AS MAY BE NECESSARY.. If approval i.3 granted, it is not to be construed to cover approval of any County or City Code Requirements. A building permit from the appropriate building department is needed on most property alterations and/or improvements. The Architectural Review Board shall have no liability or obligation to determine whether such improvement, alteration and addition comply with any applicable law, rule, regulation, code or ordinance. As a condition precedent to granting approval or any request for a change, alteration or addition to an existing basic structure, the applicant, their hires and assigns thereto, hereby assume sole responsibility for the repair, maintenance i or replacement of any such change, alteration or addition: IT IS UNDERSTOOD AND AGR]ED THAT THE PRESERVE AT LAKE MONROE HOMEOWNERS' ASSOCIATION, INC. AND CENTEX HOMES ARE NOT REQUIltED TO TAKE ANY ACTION TO REPAIR, REPLACE OR MAINTAIN ANY SUCH APPROVED CHANGE, ALTERATION OR ADDMON, OR ANY STRUCTURE OR ANY OTHER PROPERTY. THE HOMEOWNER AND ITS, ASSIGNS ASSUMES ALL RESPONSIBILITY AND COST FOR ANY ADDITION OR CHANGE AND rrS FUTURE UPKEF2 AND MAINTENA DATE: �� OWNER'S SIGNATURE: ACTION TAKEN BY THE ASSOCIATION: / i DATE: - —o APPROVED: NOT APPROVED: j AUTHORIZED- SIGNATURE FOR THE i Architectural Review Board Please submit your application and all pertinent information to: Preserve at Lake Monroe c/o Regency Professional Management 407 Wekiva Springs Rd. Ste. 205 Longwood, FL 32779 'telephone: 407-786-5100/Fax 407-786-5105 < r