Loading...
HomeMy WebLinkAbout2430-2440 S French AvePermit #:— Job :Job Address: (P -3A-5 CITY OF SANFORD, PERMIT APPLICATION E® s F"u� &P - Date: -/� (e W Description of Work: aplA-CAt-+q E-1Gt b-41 req LOT P.(ts : Ft?` 66bSquare Footage Historic District: Zoning: Value of Work: $ Permit Type: Building Electrical_ Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole _ Mechanical; Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Futures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets ` Plumbing Repair — Residential or Commercial _ Occupancy Type: Residential Commercial r/6 Industrial Construction Type: # of Storieess:� �� l # of Dwelling units: Flood Zone: (FEMA form ^required) Owners Name & Address: •�'M�� t`�^ r^ ` l Ad 15+s 71 �t7 Do 020 ' 32,536 Phone: ©7 q `4000 Contractor Name & Address: ( ""Q Fl • 12,806 Phone Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer- Address: Address: .1-V ^L C - Fla State License Number: Contact Person )-01PtC01,Ar-> Phone: 40 4U8-2,01(0 Phone: fo,? 331 —/000 Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the require iso Fl4nor/Agent Inaw, FS 713. S -l1 -O S -3-06 Signature of Owner/Agent Date afore of Date Jar\d Sa\; V1:;1L-ru r Lois rows Si tune 0'rR0 0 on a W V Qmn Signature of Notary -State Iti Notary Public State of Florida PiRICOA S. HA�v2B6' K LuAnn Giordanootary Fublac, Stale of FloEitla MY Commission DD495662 �Iy comm. expires, Mar 11, 207 Expires 0212212010 l.. n "" 'u 178829 Owner/Agent is_ Contractor/Agent is =y$54 Produced ID _ Produced ID APPROVALS: ZOl-4D.6 UTIL: FD:ENG: 3 joGBLDG:Y Special Conditions: Rev 03/2006 " NOTICE OF CONMMNCEViENT STATE OF 0 COUNTY OF C—�) ea- N—L. TM UNDERSIGNED hereby gives notice that improvementwill be made to certain real property, and in accordance with Chaptcr 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Desai tion ofproperty: (legal descri¢nli4of property, and street address if available) 2` General description of improvement: 3. Owntr information: ` ` a. Name and address:`jolpeL E Ce-- b- Interest in property: c. Name and address of fee simple titleholder (if other than owner): d. Contractor: (name and address) CCC a. Phone number: 5. Surety: a. Name and address: b. Phone number: c. Amount of bond $ 6. Lender: (name and address): a. Phone number: 7. Persons with the State of Florida designated by Owner upon whom notices or other documents may be served ai provided by Section 713.13(1 xa)7, Florida Statutes: (name and address): 8. In addition to hirnselt Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes: (name and address) 9. Expiration date ofMice of eon=neeme�nt ((tth(e�oxp'iration date is one (1) year from the date of recording unless a different date is specified) \ Lim This Space for Clerk's Use Only S APPROVED JAN 0 2 2004 G,D 6 (signature owner) . Sworn to and subscribed befote'me thiel .� .._day of M4 -V- zoos - ARY UBLIC / Notary PubNc Slate of Florida +?V-4, � Cn Gomes pp495662 ExP� OZI7�O10 Z0/Z0 39dd Itis GNd Enna vaiaoi3 SVT869ZTZE 9E:0T 900Z/9Z/00 Sk SPARTAN To build catalog numbers refer to inside front cover I 23" housing Catalog Number taunting Code WG -16 Wattage Housing 9 (add mounting rode) (Insert Cade at " in (ol. #) Size Isq.l Lamp FFS"417-1OM 1 = 1-1/2" (lase Pole Mt C', I P" 175W MH FFS"805-M(b) 2 = 6" Extended Pole Mt. SOW MH/PS FFS'807-M(b) 3 = 2" Adjustable Slip Filter 10W MH/PS I DOW MH/PS FFS"810-M(b) 4 = Yoke Mt. tiff 150W MH/PS FFS"815-M(b) 5 = 12" Extended Pole Mi. I75W MH FFM"417 lallh) 8= Without Mounting 16" 25OW MH FFM'425 lallb) 20OW MH/PS FFM"820-(a)lb) "T 25OW MH/PS FFM'825-(o)(b) 32OW MH/PS" FFM"832-(o)(b) & 35OWMH/PS'* FFM"83S-(al(b) 40OW MH"" FFM"440-(o)(b) 40OW MH/PS"` FFM"840-(a)(b) 13^ 400W MH FFL"440-00) 1000W MH— FFL"499-(a)(b) 12^ 35W HPS FFS"503-1(b) 50W NPS FFS"505-(o)(b) 70W HPS FFS"507-(a)(b) 100W HPS FFS"510 (a)(b) I5OW HPS FFS"515 lallbl 16' 150W HPS FFM"515-1a)Ib) 250W HPS FFM`525-(a)(b) 40OW HPS FFM"540-(o)(b) Y3' 40OW HPS FF1'540 (o)(b) 600W HPS FFL"560-(a)(b) (For wall mount brackets see page 47) 1000W HPS FFL"399-1a)Ib1 " Denotes reduced jacket lamp. (a)Voltage Suffix Key: Indicate voltage in space (a) Description 120 Volt 277 Volt 208 Volt 240 Volt 480 Volt Multi -top 1 2 3 4 5 M tapped CaJ 217V (b)Options: Indicate options in space (b) (Factory Installed) SUFFIX (b) Fusing F Single (120Y & 277V) (16"823" Housing Only) Specify Voltage in Suffix (a) Dual (208 240.48OV) (16123" Housing Only) Specify Voltage in Suffix (01 3 H High -2 -low Option (16"&23" Housing Only) (See Pgs. 28-29) a Quartz Standby — Specify Voltage in Suffix (al (Includes 0 lamp: 50W=12",1 SOW =16", 25OW = 23") Non delay -relay type P Photo Control - Specify Voltage in Suffix (a) A twist lock receptacle and matching photocell are supplied. (16" & 23" ONLY) While Housing (Custom Colors Available: Consult factory for pricing and delivery.) WT Black Housing I(ustom Colors Available: Consult factory for pricing and delivery.) BK A(cessories: (Field -Installed) 12" housing Description Catalog Number Wire Guard WG -12 Vandal Shield VS -12 0 See page 30 —Tenon Adaptor for restrictions. 16" housing 23" housing Catalog Number Catalog Number WG -16 WG -23 VS -16 VS -23 OFFICE [KNIT # TECHNICAL HOTLINE 1400-242-5267 FF Series Forward Throw Luminaire Lami Wattage Range: 35-1000W Mountings 1-1/2" (lose Pole Mnt. 2" Adjustable Slip Fittest 6" Extended Pole Mnt. Yoke Mount 4 Without Mntg (Factory Drilled) 17.. EX Po M ow- IS aEVIEWED coy SANER Note: All 10" & 20° Arms — Order Separately MUM -::r• :. 6" Arm - 10° Tilt MA5T10 12" Arm - 10° Tilt MA2T20 6" Arm - 20° Tilr MA5T20 12" Arm - 20° Tilt v, tt Series Desired Design . . Forward Throw Luminaire Mounting Height Dimensions Fixture Fixture Fixture Approx. o O FISTED FOR WET LOCATIONS 55 C Ambient Rated (@ length Width Depth Ship Wt. CONSULT FACTORY FOR CUL AVAILABILITY FFS Series 12.4' 12.4" 5.25" 18 LOS. 20' FFM Series 16.4" 16.4" 7.0" 381es. '" I.E.S. photometrics available by e-mail or on disk FFL Series 23.4" 23.4" 10.25" 68 Les.`, 30' 20.0 L ' 1000W 12" FFS 16"; 14.5 High Pressure Sodium 0 50' 25' 0 25' 50' 75' 50' 25' 0' 25' 50' '15 W D I EPA Rating: Listed on page 34. Housing The sleek square 12", 16" 8 23" die cast aluminum housing with flush door frame and rounded edges are standard with bronze, black or white polyester powder top coat, other colors available on request. Rotatable 23" housing — see "Optics". EPA Rating Because of its unique design, lower EPA levels are obtained, resulting in lower pole costs. optics This compact Type IV forward -throw reflector has a main beam of 600+ from vertical (300 from horizontal), providing wide lateral distribution and improved uniformities. A supplied backlight shield permits precise cutoff adjustability. The 23" housing can be rotated 904 both left and right to allow the reflector to rotate. Lens A clear, tempered glass lens is held securely in a die cast door frame. Ballast All fixtures are standard with a high power factor multi -tap ballast (except 480V). All units are supplied with a 36" SOW16/3 cord connected to requested voltage. If no voltage is specified, cord is connected to 277V lead. Mounting For complete mounting options refer to pages 42.47. Lamps The 12" housing utilizes a 50.175W medium base lamp and the 16' size utilizes 150.40OW mogul base lamps. The 23" size utilizes I OOOW MH mogul base lamps. (An ED28 lamp is standard in the 320- 40OW MH fixtures; a BT37 lamp is standard in the I HOW MH fixtures). Gasketing Complete silicone gasketing around the lens frame and at mounting points provide a watertight seal. Warranty The FF Luminaire sold by C.E.W. Lighting, Inc., unless otherwise specified, will be warranted to be free of defects in materials and workmanship under normal use and service for a period of five (5) years from date of shipment, 175*1 COOK Lower watt- ages will be warranted for (2) years. If found to be defective by us, we will replace the non-performing components. 0' 25' 50'1 1 `1-' Isofootcandle plot of 175W MH Forward -Throw Luminaire at 15' mount height, 0" vertical tilt. 50' 75' i Isofootcandle plot of 40OW MH Forward -Throw Luminaire at 25' mount height, 0° vertical tilt. 23" FFL 125' 100' 75' 50 25' 0' 25' 50' 75' 100' 125' 50' 25' o' 1 .o 25' 0. 50' S.0 l.o s 75' .1 loo' Isofootcandle plot of t000W MH Forward -Throw Luminaire at 30' mount height, 0° vertical tilt. PLANS REVIEWED Criteria: CITY OF SANFORD FF Series Luminaire 0° vertical tilt. Mounting Height: 25' Wattage: 40OW Mounting: 12" Extended Pole Mount Pole Spacing: 4 times mounting height Forward 111row luminaire Pole Spocinq Selection Guide Lamp Desired Design 50' Type Mounting Height Footcandles 25' 3 0 175W 5.0 19.6 FFS2817 40OW 20' 13.5 FFM2440 40OW 0' 1.0 100ow 30' 20.0 FFL2499 1000W 25' 50'1 1 `1-' Isofootcandle plot of 175W MH Forward -Throw Luminaire at 15' mount height, 0" vertical tilt. 50' 75' i Isofootcandle plot of 40OW MH Forward -Throw Luminaire at 25' mount height, 0° vertical tilt. 23" FFL 125' 100' 75' 50 25' 0' 25' 50' 75' 100' 125' 50' 25' o' 1 .o 25' 0. 50' S.0 l.o s 75' .1 loo' Isofootcandle plot of t000W MH Forward -Throw Luminaire at 30' mount height, 0° vertical tilt. PLANS REVIEWED Criteria: CITY OF SANFORD FF Series Luminaire 0° vertical tilt. Mounting Height: 25' Wattage: 40OW Mounting: 12" Extended Pole Mount Pole Spacing: 4 times mounting height Forward 111row luminaire Pole Spocinq Selection Guide Lamp Desired Design Catalog Type Mounting Height Footcandles Number Metal Halide 175W 12' 19.6 FFS2817 40OW 20' 13.5 FFM2440 40OW 25' 8.3 100ow 30' 20.0 FFL2499 1000W 35' 14.5 High Pressure Sodium 250W 20' 12.2 FFM2525 40OW 25' 13.1 FFM2540 40OW 30' 9.1 1000W 30' 27.4 FFL2599 1000W 35' 19.8 "Initial footcandles assume 4 floodlights per pole. 1B TECHNICAL HOTLINE 1-800-242.5261. 1 1 i h t Horizontal Tenons S RT Series i V t: I T290 RT2180 IT390 120° Triple RT3120 90, Quad RT4 (E) Round External Mount Finish Horizontal Tenons All brackets are finished with on acrylic bronze RT Series ing for longer life. The cast aluminum RT Series mounting brackets are de- signed to mount on 2.3/8" — 3" tenons on round poles. Mounting For square poles use ST Series mounting brackets. Uses 6, 5/16 allen head high tensile strength same Note: The RT290, RT390 and RT4 may not be attaching to tenon. Removable wiring cover is g used with 23" square fixtures. Use RTI tenon adap- tor for converting 2-1/8" pole tenons to 2-3/8". Catalog Number Description Horizontal Tenons Shipping Wt. (ki Single Mount RTI 4 90° Twin Mount RT290 4 180° Twin Mount RT2180 4 90° Triple Mount RT390 S 1201 Triple Mount RT3120 S 90° Quad Mount RT4 6 EPA Ratings on Page 34 for Mounting Brackets with Fixtures. PIANS REVIEWED CITY OF SANFORD TECHNICAL HOTLINE I EPA Ratings EFFECTIVE PROJECTED AREA RATING FOR FIXTURES o° 20° 30° 45° We 70° 90° -- 01:� 0 00 0 12" Square Housings With Adjustable Fitters (MA3) 0. Catalog M Y Fixtuns 0° 20° 300 45° 600 70° 90° SPB1A 1 0.66 0.91 1.03 1.21 1.26 1.31 1.32 SPB24 2in-ine 2.93 3.42 3.52 3.64 4.05 4.3) 4.35 SPB34 3 in- irb 4.84 5.54 5.70 6.02 6.54 6.80 6.85 SPB4490 40 90° 4.02 4.40 4.45 4.59 4.68 4.79 4.83 SPB44180 Ain-ine 6.74 7.65 7.79 8.40 8.71 9.32 9.38 SPB15 1 0.66 0.91 1.03 1.21 1.26 1.31 1.32 Catalog Jf • Fixtures 0° 20° 30° 45° 600 70° 90° STI /RTI 1 1.00 1.21 1.27 1.33 1.57 1.62 1.67 ST290 RT290 2 0 90° 1.62 1.78 1.90 1.96 2.05 2.10 2.14 ST2180/RT2180 20180- 1.70 1.64 1.76 1.89 2.19 2.29 2.34 ST390/RT390 3 0 90' 2.31 2.50 2.53 2.66 2.87 2.98 3.06 RT3120 3 0 120° 1.85 2.64 3.31 3.50 3.83 3.91 4.01 ST4 RTA 4 0 90° 2.31 2.50 2.53 2.66 2.80 2.93 3.00 MP) T. 1 1.10 1.25 1.30 1.40 1.60 1.65 1.70 WIT. 2 2.20 2.50 2.60 2.80 3.20 3.30 3.40 . Multiply the EPA Rating By Fixture hlount Height Toro Po Hole t Adjusted EPA 4.25 4.50 MP2T . Q 2 4.40 Catalog • M Futures 0° 20° 30° 45° 60° 70° 90" BH2 2 m - line 2.93 3.42 3.52 3.64 4.05 4.31 4.35 BH3 3 in-line 4.84 5.54 5.70 6.02 6.54 6.80 6.85 BH3T 30120 4.55 5.21 5.36 5.66 6.15 6.39 6.44 BHA 4 in-line 6.74 7.65 7.79 8.A0 8.71 9.32 9.38 BH490 4 0 90 4.02 4.40 4.45 4.59 4.68 4.79 4.83 16" Square Housings With Adjustable Fitters (MA3) 9.90 10.50 10.70 10.90 Catalog x 1T Fixtures 0° 20 30° 45660° 70 90° SP614 1 1,00 1.50 1.70 2.00 2.10 2.20 2.30 5PB24 2in-ine 3.60 4.50 4.70 4.90 5.60 5.g5_6 00 SPB3A Sin-ine 5.80 7.10 7.40 7.90 8.80 9.30 9.50 SPBAA90 A@ 90" 5.00 5.60 5.70 5.90 6.10 6.30 6.50 Spa" 180 Ain-ine 8.00 9.70 10.00 10.90 11.60 12.60 12.90 SPB15 1 1.00 1.50 1.70 2.00 2.10 2.20 2.30 Catalog At • Futures 0° 20° 300 45° 600 70o 90° 5T1/RTl 1 1.30 1.70 1.80 1.90 2.30 2.40 2.50 ST290 VsT290 @ 90° 2.10 2.50 2.70 2.80 3.00 n a n o ST2180 RT2180 2 0 180- 2.20 2.30 2.50 2.70 3.20 3.40 3.50 ST390/RT390 3@ 90° 3.00 3.50 3.60 3.80 n o n/. n a RT3120 3@120° 2.40 3,70 4.70 5.00 5.60 5.80 6.00 ST4 RTA 4 @ 90° 3.00 3.50 3.60 3.80 4.10 n o n/. WIT . 1 1.40 1.75 1.90 2.00 2.25 2.50 2.60 MP2T . 2 2.80 3.50 3.80 A.00 4.50 5.00 5.20 . Multiply the EPA Rating By Fixture -r Mount - Adjusted EPA Toro Poe Height catalog e M Fixtures 0. 20 30' 45 60 70 90° BH2 2in- ine 3.60 4.50 4.70 4.90 5.60 5.80 6.00 BH3 3 in ine 5.80 7.10 7.40 7.90 8.80 9.30 9.50 BH3T 3 @ 120 5.40 6.40 6.60 6.90 7.50 7.80 8.00 BHA 4 in-line 8.00 9.70 10.00 10.90 11.60 12.60 12.90 BH490 4 @ 90 5.00 5.60 5.70 5.90 6.10 6.30 6.50 23" Square Housings With Adjustable Fitters (MA3) catalog • Y Futures 0. 20 30 45 60 70 1. SPB 14 1 2.00 2.70 2.90 3.70 3.80 4.00 4.20 SPB24 2in-ine 6.00 7.70 7.90 8.40 9.70 10.00 10.40 SP834 3 in-line 9.70 12.00 12.50 13.50 15.40 15.80 16.20 SPBAA90 4 0 90' 8.50 9.10 9.30 9.90 10.50 10.70 10.90 SPBA4180 Ain-ine 13.10 15.60 16.00 18.40 19.90 21.60 22.00 SPB 15 1 2.00 2.70 2,90 3.70 3.80 4.00 4.20 Catalog • tY Futures 0° 20° 30° 45° 1. 70° 90° STI RTl 1 2.10 2.80 3.00 3.30 3.90 4.10 4.20 ST2180/RT2180 2 0 180° 4,00 4.20 4.40 4.80 5.80 6.00 6.20 RT3120 30120, 3.70 5.40 5.60 6.00 6.90 n a n a MPI T . 1 2.20 3.00 3.25 3.50 4.00 4.25 4.50 MP2T . Q 2 4.40 6.00 6.50 7.00 8.00 8.50 9.00 . Multiply the EPA Rating By Fixture Mount Height Toro po e H.g� Adjusted EPA Q Con Only Be Used When Facing 10° or More From The Horizontal Plane catalog Al!Fixtures 0 20° 30° 45° 60° 70° 90° BH2 2in-ine 6.00 7.50 7.90 8.40 9.70 10.00 10.40 BH3 3 'n -line, 9.70 12.00 12.50 13.50 15.40 15.80 16.20 BH3T 3 @ 90 9.10 10.50 10.90 11.70 13.00 13.30 13.60 BHA 4 in- ine 13.10 15.60 16.00 18.40 19.90 21.60 22.00 BH490 4 @ 90 8.50 9.00 9.30 9.90 10.50 10.70 10.90 34 Use these charts to calculate the correct type of pole to be used with fixtures and mounting arms selected. • Select the chart applicable to the fixture • Select the Chart applicable to the mounting arm to be used and the angle of the fixture • Check the wind speed in the area of the country the fixtures will be used. its Calculate the total weight of the fixtures and mounting arms on each pale. • Select the pole from the pole chart based on the total EPA and total weight, using the wind speed column. Allow a minimum of a 10% safety factor. • Please Note: These are guidelines only - consult your representative if you are unsure. Configuration Li QU 11 l? MAI EPA ratings for fixtures with In -Line Bracket (Only) SS824 SSB34 SSB 12' sq. housing 1.70 2.6A SSB 16" sq. housing 2.30 3.40 SSB 23' sq. housing 3.70 5.40 Configuration -❑ ❑-O I D 0-r %0 MA2 EPA ratings for 12", 16" & 23" housing with 6" Mounting Arms - ,ul _ Fi.t°re Sir. STA & RTA1 STA & RTA2180 STA & RTA290 STA & RTA390 RTA3120 STA & RTA4 12" 0.58 1.22 0.98 1.51 156 2.08 16' 1.00 2.10 1.702.60 3.60 23" 2.00 4.10 n/a n/a n a MA5 EPA ratings for 12", 16" & 23" housing with 12" Mounting Arms Fixture Size STA & RTA 1 STA & RTA2180 STA & RTA290 STA 14 RTA390 RTA3120 STA 8 RTAA 12" 0.68 1.20 1.43 1.71 1,82 2.28 16" 1.20 2.50 3.00 3.00 3.20. 4.00 23" 2.20 4.40 4.00 5.50 5.90 7.50 MA2T10 EPA ratings for 12",16" & 23" housing with 10a/20a tilt - 6" Arms Flxlen St.. STAIT20 STA218OT20 STA29OT20 STA39OT20 STA3120T20 STA4T20 12' 0.70 1.15 1.20 1.70 1.80 2.40 16" 1.30 2.10 2.20 2.30 3.10 4.40 23" 2.50 3.60 n o n a n a "Note:For MA2T20 EPA, Refer to 20° Column on Table to Left. EPA ratings for fixtures with Wishbone Mount (WB) (0' tilt) w/flat lens WBR WBS 12" sq. housing n/a n/a 16" sq. !us 1.10 1.10 23" sq. us !in 2.20 2.20 PLANS REVIEWED C11Y OF SANFORD EPA ratinas for FBD Series Floodliaht Degree Tilt 01 20° 30° 45° 60° 701 901 Yoke Mount: 1.30 1.70 1.80 1.90 2.30 2.40 2.50 Tenon Mount (FBD-TM): 1.40 1.80 1.90 2.00 2.40 2.50 2.60 Trunnion Mount (FBD-TR): 1.40 1.80 1.90 2.00 2.40 2.50 2 60 Configuration --j] 0-0 r D_Er�_F_] y EPA ratings for 23" FAL/FVL Series luminaire (0° tilt) Vertical w/sag lens Number of Fixtures 1 2490 24180 3@90 3@120 4@90 6" Ext. Pole Mount arm (MA2): 23" sq. housing 2.20 n/a 4.30 n/a n/a n/a 12" Ext. Pole Mount arm (MA5): 23" sq. housing 2.40 4.20 4.60 5.70 6.10 7.70 Wishbone Mount (WB): 23" sq. ousing 2.40 n/a n/o n/o n/. n/. TECHNICAL HOTLINE 1-800-242-5267 U4/U5/U0 "hi) Ud Oti MA i 4U1 011 42!11 lVllli'ClC - JU1C/Gll1jiJL1Y �vvi CONCRETE VOLUME = 0.28 , 8 C.Y. 0 4" CAST IN 2"o / I GALV PIPE 12" LONG. WRAP WITH HARDWARE CLOTH 1" EMT 30" / III I) I) III II 1"0 P.V.C. #4 STRANDED GROUND WIRE W/18" PIG TAIL CONN. TO STRAND W/UCK-3 CONN, POLE WEIGHT = 1,212 LBS CONCRETE F'c = 6500 PSI ULTIMATE CAPACITY @ 2' = 1.2 ki s 8" (TCP FACE) TIP END VIEWED FROM BUTT Y i CAST IN 1"0 045' #4 STRANDED. GROUND WIRE W/18" PIG TAIL CONN, TO STRAND W/UCK-3 CONN, TOP FACE SI[ E FACE JOB# W/CAST I /CAST "T 11S�01�1-0�1T SHT: 1 of 11 HE 61; ACAD STOCKSQUARE T1S-027TJ DATE, 4-8-04 BUTT END VIEWED FROM PUN$ REV " l ® PRESTRESS 250K (4) 1/2 @ 14,500 LBS DORMANT m_u# ON ORDER QTY. IC C✓ O R D (407) -1--7675 INDUSTRIES A I III CAST IN 2% 5" H/H & COVER I I FACE. RIENF W/ (2) #4 x 18" I I I REBAR ^� W 1 Cn J , JI CL o co N V)Lo #4 STRANDED GROUND WIRE W/18" PIG TAIL CONN. TO STRAND W/UCK-3 CONN, POLE WEIGHT = 1,212 LBS CONCRETE F'c = 6500 PSI ULTIMATE CAPACITY @ 2' = 1.2 ki s 8" (TCP FACE) TIP END VIEWED FROM BUTT Y i CAST IN 1"0 045' #4 STRANDED. GROUND WIRE W/18" PIG TAIL CONN, TO STRAND W/UCK-3 CONN, TOP FACE SI[ E FACE JOB# W/CAST I /CAST "T 11S�01�1-0�1T SHT: 1 of 11 HE 61; ACAD STOCKSQUARE T1S-027TJ DATE, 4-8-04 BUTT END VIEWED FROM PUN$ REV " l ® PRESTRESS 250K (4) 1/2 @ 14,500 LBS DORMANT m_u# ON ORDER QTY. IC C✓ O R D (407) -1--7675 INDUSTRIES A i r 04/,05/06 WED 09:39 FAX`1 407 SUPPORT MAX..'EPA _OF �1"E CAST IN 2"0 GALV PIPE 12" LONG, WRAP WITH HARDWARE CLOTH 1"o P.V.C. ►'r7 CAST IN 2"x 5" H/H & COVER FACE. REINF W/ (2) #4 x 20" REBAR e - Sale/Eng/Ship 16002 ii i I #4 S1RND G. R, W/18" PIG TAIL CONN. TO STRAND W/UCK-3 COKN, 1" EMT s 30" I i) 1I III TIP E:ND VIEWED FROM BUTT 9 ,A.. TOP FACE SIDE I -ACE W/CAST W/GIST SH T: 1 of 11 He: K1ACAD\STOCK\T15-032T' DAZE: 12--3(-04 z i BUTT END I a L i CAST IN 1-0 VIEWED FRO,��1 UTT 045"06 �V4J 4JL ��dD( 00 e ®� O L I PRESTRE co 1 r N i LD - #4 STRND G.W. 250K W/18" PIG (4) 1/2" 0 14,: TAIL CONN. TO STRAND W/UCK-3 CONN. DORMAN TOP FACE SIDE I -ACE W/CAST W/GIST SH T: 1 of 11 He: K1ACAD\STOCK\T15-032T' DAZE: 12--3(-04 Lo LO CD CD s N N O✓ 1 w d 0.1 D.1 3 9 NZ.4 N m a. 1.3 2.4 2-0 -.7 !� g m .3 �,2 3.2 5.Fi 4.4 1.5W. 6ti, .. 2.t3 4.3 B.1 10.8 1.6 4.0 6.5 7.0 2_i N 0. 2I 3.9 2.9 3.1 En 00 III 0.1 0. a 40.4 1,4 .9 13 1.0 0.9 4 a .1 3.1 0 0.4 0.9 0.1 0.1 0 0 0.9 0.9 4 0.1 0.1 0 0.'t" 0 o Q a o .a2o 0 o0aia2a2o a o .o2a2.6 o0 . aI.4 n2 .01 0.1 02 0. 1.5 2.7 2 2. 0.0 0.1 0.1 .9 12. 9 5.5 6.7 5.5 '2. 8 B n.3 .9 2.9 5.6 6.7 5.4 ,6 n,8 3 .9 2,9 5,6 J 5.5 2.6 .8 40.3 9 2-9 5. 13 93 ti 2 0.0 0.0 0.1 3 1.4 4,2 0.01 7.9 4.2 1.5 0. L,6 4.4 8.5.1 7.4 3.9 1. 0. 1.6 4.4 0..1 7.5 4.0 E.4 0 l.b 4.4 B. v o 0 0 a o 0 *10. a e n a a o 0 0 0 0 a o n a o o o a 0 o a a a 0.0 0.0 0.1 0, 3 2,6 6.5 10.7 6.5 2.6 1 0. 1.4 23 6.8 10.6 6,1 2.5 0. 1.4 2.7 6.8 10.6 6.3 32 1.8 1.1 1.4 2.7 G. • V. a 0 o a o 0 o or 0.8 1. 2 .9 4.00 0.1 0, l9 9 �..1 . . 3 a a a a o a �D (L a 13 0.0 0.0 0.1 4.2 0,9 1.5 1.6 1.5 .9 0.4 0.3 0,5 0.9 1.5 l.6 1.4 0.8 0.4 0.3 0.5 0.9 1.51 1.7 2.1 5.2 7. 5,9 0.7 1.9 1. to c PHnTnMt'TRIC LIGNTI�lG �'E-AIN ENTRANCE FM a 25 50 75 100 SCALE, 1' = 20' nhoh-e Sc�eniute ojeCCb Project_1 mbd. Qty Descrlpt!on FI[erxine Lumens Ll_F 4 3 - 404WT MH FRWD/THRW - FFH2440 a 25' AVG FFM4400.IES 32M 0.590 1 2 - 400VT MN FRWD/THRW - FFN?-440 e 25' RFG FFM4401MES 32000 40.590 1 400WT MH FRVD/THRV - FFM2440 6 20' AFG FTM4400.1cs 32D00 0.59D t*xwric SVnnary Project Project _1 u DescrlRtlon Aim PAR4(1*G/DRIVE 2.m 0.1 01: ;0.3.-II.7"0.9 10.4 01 , 0;3" 1.3 2.4 2.0 0.7 03 / 1.2 3.2 5.6 4.4 1.5 0.6 2.0 4.3 8.1y8.8 2.7 01 5`. 1.6 4.0 6.5 7.0 2.1 02,0.6- 2.1 3.9 2.9 1.1 0.1 0,2 06 14 1.4 0.9 1.0 D 0.9 09 04 0.1 o D D o 0.1 02 Q.5 19 0.9 0'9 0.4 0.1 D __ 01 02/05 0.9 _ 0.9 0:9 04'.. 0.1 0.1 02,,' O5' 0,9 0.9 09 0,41 0.1 0.0 0.0 0.0 0.0 LLF + 4 3 - 40OWT MH FRWD/THRW - FFM2440 @ 25' AFG FFM4400.1ES 32000 0.590 4 t 2 - 40OWTMH FRWD/THRW - FFM2440 @ 25' AFG FFM4400.1ES 32000 /... l 40OWT MH FRWD/THRW - FFM2440 @ 20' AFG FFM4400.IES 32000 0.590 0.1 0.1 02,04 �,7 1.5 2.7 2.2 2.7 13 'D0.3. 02 0.3 1.4 2J 22 2.6 l.2 0>3 0.2/;03 1.4 2.7 2.2 2.6 12 9 02 ;03 t.4 2J 2.2 26 1� ;0,3 0.1 0.0 0.0 0.0 0.0 0.1 0.1 d Z /0.9 2.8 5.5 6.7 5.5 2.8 0.8 06 A.9 2.9 5.6 6.7 5.4 2.6 0 8 . 0t3 ; 0.9 2.9 5.6 .7 5.5 2 6 0.8 0/.3 .,0.9 2,9 5.5 6.7 5.4 2.6 110 7, '; 0.1 0.1 0.0 0.0 0.0 0.0 D o 0.1 1013 L4 4.2 8.0`1t� *4e7," 77 1 7.9 4.2 1.5 o ti�DL, �� 06 1.6 4,4 85'. ,1 7.4 3.9 14 o 0.f 1.6 o 4.4 8.5°'l 1 7.5 4.0 %o�'o 1.4 1.6 4.4 85 1 7.4 3.9 13 0.2 0 O.l 0.0 0.0 ..Orb 0.0 0.0 0.1 `0 4 \1.3 2.6 6.5 10.7 6.5 2.6 1,3 0.7 . L4 2J 6.8 10,6 6.1 2.5 t:3 0.7' . 1 4 2J 6.8 10.6 6.3 3.2 1.8 D11 1.4 2J 6:8 10.6 6.1 2.5 Y 2, 0.3 0.1 0.0 0.0 0.0 0.0 Ol 03 07., 1.7 3.9 5.0 3.9 18 0.8 0.5 0:8. 1.9 4.1 5.0 3.8 17-- 0.8�'0�� 08 1.9 4'.1 5.1 4.3 4.2 3.5 2.3 T'0 L9 4.1 5�0 3.8 1.6 07o-,2 0.1 0.0 0.0 0.0 0.0 0.1 0 2 0,4' 70.9 L5 1.6 1.5 70.9 0.4 0.3 0.5 0.9 L5 L6 t.4 0.8 70.4 0.3 0.5 0.9_ 1.5i 1.7 2.1 5.2 7." a 5.9 0.7 70.9 1.5 ,6 1 4 0.8 0.3 0.1 ).1 0.0 0 0 PHOTOMETRIC LIGHTING PLAN ENTRANCE 0 25 50 75 100 SCALE: P = 20' luminaire Schedule Description Avg Max Min Avg/Min Max/Min Projects Project -1 0.0 0.00 0.00 Symbol Qty Description Filename Lumens LLF + 4 3 - 40OWT MH FRWD/THRW - FFM2440 @ 25' AFG FFM4400.1ES 32000 0.590 4 t 2 - 40OWTMH FRWD/THRW - FFM2440 @ 25' AFG FFM4400.1ES 32000 0.590 l 40OWT MH FRWD/THRW - FFM2440 @ 20' AFG FFM4400.IES 32000 0.590 Numeric Summary Project: Project -t Description Avg Max Min Avg/Min Max/Min PARKING/DRIVE 2.18 t3.1 0.0 0.00 0.00 Filename FRMRFRN3.a32 NOTES:-_-- THIBLIGHTI?i;,DEBION IS BASED ON INFORMATION PROVIDED BY OTHERS, ACTUAL RESULTS MAY DIFFER FROM DESIGN, DUE TO INACCURATE, ADDITIONAL OR MISSING CRITICAL SITE INFORMATION THAT IS PERTINATE TO THIS DESIGN, SNINAR CORPORATION OR CEW LIGHTING IS NOT RESPONSIBLE FOR DIFFERENCES IN DESIGN VERSUS ACTUAL PERFORMANCE BASED ON THIS SITE INFORAIA-, J ILLUMINANCE`/ALOES SHOWN ARE CALCULATED FROM THE LUAIINNRE LABORTORY TEST DATA LISTED. LABORATORY TEST ARE MADE UNDER OPTIMUM CONDITIONS. WITH LNJP OUTPUT AT RATED VALUE AND IN ACCOROANCE'NTH ILLUMINATING ENGINEERING STANDARDS. 1 -- Scale: AS SHOWN Date: 2-22-06 Project# FRMRFRN3.A32 Drawn By: D.A.O. Email: doneal@elmkar,com Sheet Size: D L IGHTING APPLICATIONS Phone: 800-811-8236 Fax: 972-692-6654