HomeMy WebLinkAbout301 Terrace CtCITY OF SANFORD PEIRMIT APPLICATION Permit # : n 7i `l U Date: Job Address:'M 3 0 T - LA -A -t 4 ('e VY.— '5 A' F-0 a -D �— 3 -'7 7 3 Description of Work-? n_ hObl'&-- Total Square Footage Historic District: Zoning: Value of Work: S -1p g 7_1 7d' Permit Type: Building " Electrical Electrical. New Service - # of AMPS Mechanical: Residential Non -Residential _ Plumbing/ New Commercial. # of Fixtures Plumbing/New Residential: # of Water Closets _ Occupancy Type: Residential Commercial Mechanical Plumbing Fire Sprinkler/Alarm Pool Addition/Alteration Change of Service Temporary Pole - Replacement New (Duct Layout & Energy Calc. Required) # of Water & Sewer Lines # of Gas Lines Plumbing Repair - Residential or Commercial _ Industrial Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) Owners Name & Address: a' 4Q J Pt+."P-4 ew -3,0 1 T"& -IL t e6- C -T S s}'+�oK 0. ��— i Phone . Contractor Name & Address: Phone & Fax: Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer: Address: State ' is ase Number: Contact Person: .. -.1 _ Phone: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. 1 w.-fc�fvj i Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 A"C: tL DETAIL 21 DAVID JOHNSON, CFA, ABPA, i !! PROPERTY APPRAISER 30 g . ` + SEMINOLE COUNTY FL. O p 1101E. FIRST sT SANFORD, FL 32771.1468 m ' ♦ ' ` `} 407-665-75 Gee. � .i 17S 2006 WORKING VALUE SUMMARY GENERAL Value Method: Market Parcel Id: 02-20-30-508-0000-03A0 Number of Buildings: 1 Owner: MACPHERSON PATRICIA R & Depreciated Bldg Value: $83,573 Own/Addr: RUSSELL P Depreciated EXFT Value: $600 Mailing Address: 301 TERRACE CT Land Value (Market): $11, 0 City,State,ZipCode: SANFORD FL 32771 $00 Land Value Ag: $ Property Address: 301 TERRACE CT SANFORD 32771 Just/Market Value: $95,173 Subdivision Name: TERRACE THE Assessed Value (SOH): $49,819 Tax District: S1-SANFORD Exempt Value: $25,000 Exemptions: 00 -HOMESTEAD Taxable Value: $24,819 Dor: 0103-TOWNHOME Tax Estimator SALES 2005 VALUE SUMMARY Deed Date Book Page Amount Vac/Imp Qualified Tax Value(without SOH): $859 WARRANTY DEED 10/2001 04202 0267 $37,800 Improved Yes 2005 Tax Bill Amount: $466 WARRANTY DEED 05/1987 01853 0976 $57,000 Improved Yes Save Our Homes (SOH) Savings: $393 WARRANTY DEED 03/1984 01529 0414 $49,000 Improved No 2005 Taxable Value: $23,368 WARRANTY DEED 11/1981 01366 0019 $215,200 Vacant No DOES NOT INCLUDE NON -AD VALOREM Find Comparable Sales within this Subdivision ASSESSMENTS LAND LEGAL DESCRIPTION Land Assess Frontage Depth Land Unit Land PLATS: Pick... Method Units Price Value LEG LOT 3A THE TERRACE PB 24 PGS 75 - LOT 0 0 1.000 11,000.00 $11,000 77 BUILDING INFORMATION Bid Year Base Gross Living Est. Cost Bid Type Fixtures Ext Wall Bid Value Num Bit SF SF SF New 1 SINGLE 1982 8 790 1,619 1,580 BRICK+WOOD $83,573 $92,346 FAMILY COMBO Appendage / Sgft UTILITY FINISHED / 39 Appendage / Sgft UPPER STORY FINISHED / 790 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished,Base Semi Finshed EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New FIREPLACE 1982 1 $600 $1,500 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. "' If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www. scpafl.org/pls/web/re_web. seminole_county_title?parcel=022030508000003A... 6/23/2006 CITY OF SANFORD BUILDING DIVISION OWNER/BUILDER AFFIDAVIT CONSTRUCTION CONTRACTING Owners of property when acting as their own contractor and providing direct, onsite supervision themselves of all work not performed by licensed contractors, when building or improving farm outbuildings or one -family or two-family residences on such property for the occupancy or use of such owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such structure by the owner -builder within 1 year after completion of same creates a presumption that the construction was undertaken for purposes of sale or lease. This subsection does not exempt any person who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The owner may not delegate the owner's responsibility to directly supervise all work to any other person unless that person is registered or certified under this part and the work being performed is within the scope of that person's license. For the purposes of this subsection, the term "owners of property" includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this subsection, an owner must personally appear and sign the building permit application. State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct, onsite supervision of the construction yourself. You may build or improve a one -family or two-family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I, �-vs s vm-P /'j14-A4v-se, Pew , do hereby state that I am qualified and capable of performing the requested construction involved with the permit application filed. I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work allowed by law on the permitted structure. G5gt= 4(/J i /n/,, Owner/Builder Signature Date "/ Print Owner/Builder Name Signature of Notary—State of Florida Date Owner is Personally Known to Me or Produced ID t.,\ , , 4 1 ) 0 10 DEBBIE BLANTON MY COMMISSION # DD 1894®1 (Z EXPIRES: February 25, 2007 1eOO4N TARY FL Notary Dftou,t ASS= Co. e Terrace Association iwaL Myrtis Mims Vice President 499 Terrace Court Sanford, FL 32773 Date: June 19, 2006 To: City of Sanford Attn: Permit Department 300 N. Park Avenue , Sanford, FL 32771 , From: Myrtis Mims Vice President Terraceo e eesociation Subject: New Door Unit 301 ' The purpose of this memo is to advise the City of Sanford that the outside door being installed in Unit 301 owned by Patricia and Russell MacPherson meets the Terrace Association rules and regulations. If you have any questions please let me know. I MI� A PRODUCT CONTROL NOTICE OF ACCEPTANCE Premdor Entry Systems 911 E. Jeferson, P.O. Box 76 Pittsburgh ,KS 66762 MUMI-DADS COUNTY, &OPDA METRO -DARE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAOLER BUILDING 140 WEST FLAOLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 17ONTRACTOR LICENSING SECTION (303) 373.1527 FAX (303) 373-1358 CONTRACTOR ENFORCEMENT DIVISION (303) 373-2966 FAX (303) 375-2908 PRODUCT CONTROL DIVISION (303) 375-2902 FAX (303) 372.6339 Your application for Notice of Acceptance (NOA) of: Entergy 6-8 SIE Inswing Glazed Double w/sidelites Residential Insulated Steel Door under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at any time from it jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined by BCCO that this product. or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 01-0314.17 EXPIRES: 04/02/2006 Raul xoanguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECMC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMIVIITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dade County, Florida under the conditions set forth above. APPROVED: 06/05/2001 Francisco J. Quintana, R.A. Director Miami -Dade County Building Code Compliance Office %0450001*2000M1%"1aWn*0ce accepUnee cover pap dot Internet mail address: postmaster@buildingcodeonline.com (0 homepage: bttp://www.buildingcodeonHne.com Premdor Entry Systems ACCEPTANCE No.: 01-0314.17 APPROVED JuN 5 70M EXPIRES April 02, 2006 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS I. SCOPE 1.1 This renews the Notice of Acceptance No. 00-0321.19 which was issued on April 28, 2000. It approves a residential insulated door, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series Entergy 6-8 WE Inswing Glazed Double Residential Insulated Steel Doors w/Sidelites and its components shall be constructed in strict compliance with the following documents: Drawing No 31 -1028 -EM -1, Sheets 1 through 6 of 6, titled "Premdor (Entergy Brand) Double Door with Sidelites with 1/8" Glass- in a Wood Frames with a Bumper Threshold (Inswing)," prepared by manufacturer, dated 7/29/97 with revision C dated 01111/00, bearing the Miami -Dade County. Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications of pair of doors and single door only, as shown in approved drawings. Single door units shall include all components described in the active leaf of this approval. 3.2 Unit shall be installed only at locations protected by a canopy or overhang such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. Unless unit is installed in non -habitable areas when the unit and the area are designed to accept water infiltration. 4. INSTALLATION 4.1 The residential insulated steel door and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): the installation of this unit will require a hurricane protection system. S. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South 'da Building Code (SFBC) in order to properly evaluate the instal 'on f this syst Man el Perez, P.E. Product n 1 Examiner Prodhet,Cbritrol. Division 2 Premdor Entry Systems ACCEPTANCE No.: 01-0314.17 APPROVED JUN 0 5 2001 EXPIRES ARM 02, 2006 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as. approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer needs not reseal the copies. S. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEP Cv. Manue e , P.E., Product Co xaminer Produc ontrol Division 3 Premdor Entry Systems ACCEPTANCE No.: 01-0314.17 APPROVED JUN 0 5 2001 EXPIRES : _ April 0Z. 2006 _NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED (For File ONLY. Not part of NOA.) A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 31 -1028 -EM I, Sheets 1 thru 6 of 6, "Premdor (Entergy Brand) Double Door with Sidelites with 1/8" Glass- in a Wood Frames with a Bumper Threshold (Inswing)," prepared by manufacturer, dated 07/29/97 with revision C dated 01/11/00. B. TESTS 1. Test reports on 1) Air Infiltration Test, per SFBC PA 202-94 2) Uniform Static Air Pressure Test, Loading per SFBC PA 202-94 3) Water Resistance Test, per SFBC PA 202-94 4) Small Missile Impact Test per SFBC, PA 201-94 5) Cyclic Wind Pressure Loading per SFBC, PA 203-94 6) Forced Entry Test, per SFBC 3603.2 (b) and PA 202-94 along with marked -up drawings and installation diagram of metal edge double door with 1/8" glass in a wood frame with bumper thresholds, prepared by National Certified Testing Laboratories, Test Report No. NCTL 210-1897415,6 (S) (I), dated 01/30/97 revised on May 28, 1997, tested on January 07, 1997, signed and sealed by Barry D. Portnoy, P.E. C. CALCULATIONS 1. Anchor calculations prepared by Product & Application Engineering, Inc., Project No. 97- 0102,. Report No. 02, dated December 27, 1996, signed and sealed by David A. Terwilleger, P.E. D. MATERIAL CERTIFICATIONS 1. Tensile Test prepared by ATC Associates, Inc., Report No. D71254, dated February 27, 1997, for steel samples, tested per ASTM E8-96 after the coatings were removed, signed and sealed by Peter G. Read, P.E. 2. Report titled "Small Scale Fire and Hose Stream Tests on 20 Min. (BASF Elastopor) Foam -Core Door" prepared by Underwriters Laboratories, Inc., File No. R18466, tested per ASTM E-152, dated July 3, 1997, signed by Dick Walther and reviewed by Howard Gruszynski. 3. Report #WH1 495-0941, titled "Report On The Fire Endurance And Hose Stream Testing Of Two Single Swing 3' 0" x 7' 0" Door and Frame Assemblies in a Masonry• Wall" prepared by Warnock Hersey International, Inc., and tested per ASTM &152, on December 15, 1988. Manuel z, P.E. Product ConIqlxaminer Product ontrol Division E-1 Premdor Entry Systems E. ACCEPTANCE No.: 01-0314.17 APPROVED . JUN 0 5 2001 EXPIRES ARU 02.2006 NOTICE OF ACCEPTANCE: EVIDENCE SUBNIITTED (For File ONLY. Not part of NOA.) 4. Report No. 114884-1, titled "Flammability" per ASTM D635-97" Rating of Burning and/or Extent and Time of Burning of Self -Supporting Plastics in a Horizontal position," prepared by SGS US Testing Company Inc., dated Nov. 24, 1998, signed and sealed by Joseph G. Cappetta, P.E. 5. Report No. 114884-2, titled "Ignition properties" per ASTM D1929-96" Testing Ignition Properties of Plastics," prepared by SGS US Testing Company Inc., dated Nov. 24, 1998, signed and sealed by Joseph G. Cappetta, P.E. 6. Report No. 114884-3, titled "Smoke Density" per ASTM D-2843-93" Measuring the density of Smoke from the Burning or Decomposition of Plastic," prepared by SGS US Testing Company Inc., dated Nov. 24, 1998, signed and sealed by Joseph G. Cappetta, P.E. 7. Report Titled "Tensile Method for Plastics, d638,mia," specimen name: "White Fina Control," dated 5/16/99, prepared by Celotex. 8. Report Titled "Tensile Method for Plastics, d638,mia," specimen name: "White Fina Exposed," dated 5/16/99, prepared by Celotex. 9. Report Titled `"Tensile Method for Plastics, d638,mia," specimen name: "Tan Fina Control," dated 5/16/99, prepared by Celotex. 10. Report Titled "Tensile Method for Plastics, d638," specimen name: "ODLI-2 Weathered 12 month Exposure," dated 12/8/99 prepared by Celotex. 11. Summary Report for ASTM D-1929-, ASTM D-2843-, ASTM D-635-, ASTM G -26/D- 638-, prepared by ODL, dated August 26, 1998, signed and sealed by Steven R. Wilkening, P.E. 12. Report No. ODL-01-02-01, titled "Standard Practice for Operating Light Exposure Apparatus (Xenon -Arc Type) With and Without Water for Exposure of Non-Mertallic Materials" per ASTM G 26 and "Standard Test Method for Tensile Properties of Plastics" per ASTM D 638, dated December 14, 2000 for ODL HP Polypropylene lite frame material, issued by PRI Asphalt Technologies. STATEMENTS 1. None F. OTHERS 1. ' Notice of Acceptance No.00-0321.19 issued to Premdor Entry Systems for their Premdor (Entergy Brand) Double Door with Sidelites with 1/8" Glass- in a Wood Frimes with a Bumper Threshold (Inswing) dated 04/28/00, expiring on 04/02/01. Minu)A Perez, P.E. Product CV Examiner Prod c ntrol Division E-2 Premdor Entry Systems ACCEPTANCE No:: 01-0314.17 APPROVED . JUN 0 5 2001 EXPIRES : AgrU 02.2006 NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED (For File ONLY. Not part ojNOA.) TESTS PERFORMED: RESULTS: TEST TEST LOADS DESIGN LOADS AIR INFMTRATION @ 1.57 PSF 0.17 CFM/Fre SFBC PA 202-94 0.50 CFMIF ?) UNIFORM STATIC' PRESSURE 8 DESIGN LOAD +50.5 PSF +50.5 PSF SFBC PA 202-94 POSITIVE UNIFORM STATIC PRESSURE ® DESIGN LOAD -50.50 PSF -50.5 PSF SFBC PA 202-94 NEGATIVE WATER RESISTANCE (PSF) Not Qualified SFBC PA 202-94 UNIFORM STATIC AIR PRESSURE (a3 FULL TEST LOAD +l 14.0 PSF +76.0 PSF SFBC PA 202-94 POSITIVE UNIFORM STATIC AIR PRESSURE (a1 FULL TEST LOAD -114.0 PSP -76.0 PSF SFBC PA 202-94 NEGATIVE FORCED -ENTRY RESISTANCE (FER) SATISFACTORY SFBC Section 3603.02 and SFBC PA 202-94 Dedsp Prmm Ratin altive 450.5 PSF Dedgn Preuure Rating (Negative) -50S PSF Manuel P.E. Product Co a miner Product Control Division E-3 PREMDOR (ENTERGY BRAND) DOUBLE DOOR WITH SIDELITES W/ 1/8' GLASS - IN A WOOD FRAME W/BUMPER THRESHOLD (INSWING) q_MjATKVM6 ATTACH ASTRAGAL THOU DOLT STRIKE PLATE TO THE HEADER AND TFREMD VITN 010 x 1 3/1' FLATHEAD SCREVS NOTES, 00x1'LOW HOLESmml-l— IN ALL REMAINK 1931 1) VOOD DUCNS BY OTHERS. MUST DE ANCHORED 00 x 1 3/4' LONG PROPERLY TO TRANSFER LOADS i0 THE STRUCTURE. FIATMEAO WREVS t.) THE PRECEDING DRAVINGS ARE INTENDED TO QUALIFY THE FOLLOWING INSTALLATIONS. A VUUD FRAME CONSTRUCTION VIIEK DOOR SYSTEM IS ANCHORED TO A MINIMUM TVO BY VOOD OPENING, ASTRAGAL LK INSWING RK IRSVING 1. MASONRY OR CONCRETE CONSTRUCTION WHERE DOOR SYSTEM 13 ANCHORED TO A MINIMUM TVO BY APPR9MA30aMpLyMVMrS STRUCTURAL WOOD DUCKsovNM OURasN00N10[ C. MASONRY OR CONCRETE CONSTRUCTION WHERE SYSTEM �ATNON-STRUCTURAL YAMSMITiM[EDDBy VAT �AN pDODR V��TMM �RVITHOUTED DIE DY WOOD DllClt. IIDL IE i 3. ALL ANCHORING SCREWS TO BE 110 WITH 'H r KVJ" �oo0c�lyxNcaorMCO W U%Ml MINIMUM 1 1/e" EMBEDMENT INTO WOOD SUBSTRATE EHNp. y. N7 OR 3/16' PFH TAPCI>fli WITH 1 1/2' MINIMUM EMBEDMENT I UMTS SWAN K INSTKLED KY AT LOCATIONS PROTECTED DT A CAIN OR INTO MASCNRY. OVUM SUCH HMT THE NIQE BENEFIT THE EDGE 6 CK" OR OVERIM /. UNIT MUST BE INSTALLED VITN 'MIAMI -DADS COUNTY 10 SILL IS LESS TWA 0 DLOIEES. MESS WIT IS INSTALLED IN APPROVED' SHUTTERS NIN-IMINTA<E MEAS V4X THE WIi NO TME AREA ARE DESIKII TO I THREE .STAPLES PER SIDE JAMB INTO HEADER ON SIDELITES ACCEPT VATER PaTRA1DDl AND DOOR. THREE STAPLES PER JAMB INTO THRESMOLD ON SIDELITES AND DOOR. L LATEX SEALANT TO BE APPLIED AT SIDE BY SIDE JAMBS AND SIDELITES. 7. DOOR/SIDELITE HEADER. DOOR/SIDELITE JANDS. AND IIDELITE BASE CORNERS ARE COPED AND BUTT JOINED. 8 WS SWU BE PRE -PAINTED VITN A VATER-BASED EPDXY RUST INHIBITIVE PRIMER PAINT VITN A DRY FILM THICKNESS OF 00 10 12 NIL A FRAMES SWILL BE PRE -PAINTED VITN AN ACRYLIC LATEX VATER-BASED/ VATER-REOUCIQE VHITE PRIER VITN A MY FILM THICKNESS Or 09 10 12 MIL. rMltil 1/2' GLASS BITE GLAZING DETAIL Tt WMI MAU INTERIOR 11,43WlINU OTHER CONFIGURATIONS AffM0MAsmavW WM,W a er a� •acM0000tcowu 80 11/16' Z. MAX INTERIOR 79 5/16' MAX BY V000 BUCK 640 MAX DLO _I 4 9/16' SECTION B -B 17 1 1/4' ALUMINUM ASTRAGAL PREMDDR (RANO OR EOWVALENT- 5/8' ALUMININ ASTRAGAL 1 ALUNWII-RWR THREMD EN -IS PREMDOR BRAND OR EOUIVN.ENT - 1 1/1' x 1 9/16' TOP CHANNEL EM -06 PREMDOR DRANO - 1 Il/16' - 20 GA STEEL QD STEEL SKIN a 2L (810IN -0 ammisloomse DENSITY ZO TO 21 1 JFt° rOWOOD TT EM -07 1 PREMDOR DRANO - 1 11/16• - 20 GA STEEL L LOCK EM -09 1' X 9 I/2' NTL TO DE PINE OR EQUIVALENT EXTERIOR 1 STRIKE STILE EN -06 PRENDOR IRMO - 1 11/16' - 20 GA STEEL II HINGE STILE 04-05 PREMDOR DRANO - 1 11/16' - 20 GA STEEL LOCK PREP FILLER PLATE EM- 0 PREMDOR WAND - AW THICK- MTL. IO BE POLYETHYLENE 1'x1' HINGE EN -16 HALER BRAND NNE OR EQUIVALENT - 497 THICK (STEEL) W000 HINGE JAMB 1 1//' X 1 9/16' NTL TO BE PINE OR EQUIVALENT 110-21 x 1/2" rxxS. no x z• Fxvsat (4) SCREWS PER MIKE INTO DOOR Nr ���JVA mwo st0CU1 Jot r sow "m up so[vs TMaia tAa Sis0.1TF m mm sinim. r sow IXM suit Al EU[VATAT VIEV, FOR I Or SCREWS UZI NO UVTpIS 110 X 3/4' FxVS 0 SCREVS PER HN[i INTO .IAMB 18 x 2' rxV.S. 10 SCREWS AT EACH STROIE PLATE 22' X 61' SINGLE PANEL SIDELITE TRIM (WOOD) 1 1/4' 0*6X ASING IDELITE HEAD JA IDELITE BASE PYLENE LITE TTG /2'PAW HEAD S STILES PIN NAIL DOW SILICONE #995 RPRId °A + Pon cnalwA;eaw+�s HP uNr AV- � � na 00. AAI r ¢ AE1biFRR. ILEI a ALL1476 A Tew� —1028—EM—I SHEET 3 OF 6 B[Y610r LETTER B 1/4' SHIM MAX 3/4' 3/16' INTERIOR 79 MAx 80 11/16' I MAX 2 BY WOOD BUCK 64' MAX DLO 2 BY WOOD BUCK--` 4 9/16' SECTION C -C 1 1/4' 7 EXTERIOR PLEASE SEE 'GLAZING DETAIL' — DRAWING #31 -1028 -EM -I SHEET 2 OF 6 1 1/4' DOW SILICONE #995 AMOMASCpMU'CI WATHM MIV PREMDOR ENTRY SYSTEMS 1 -1028 -EM -1 ! 'Al E00 l SHEET 4 OF 6 nT a OW LEM n �- OTHER DOOR CONFIGURATIONS 11 w A '— • • r r r r r r r r r r r r r r r r r M W • n r % rs•—i n r s s _ ..u. u. s •r. =a . a s is s r oxxL1L1.LliJ K W r r r •r . r — r r r r r _ r r r r r r r r r u'ws—i ' ' ` iswia—• � _ •e �_ � s v. . r _ � r r �� • r w �r r r r r XD oXD x u� m mn. ras I WE ��ereo as carv�rwo ern iwE same a gE oe'PREM- 0OR LNIRY MIEMS 31 -1028 -EM -I o v W L 4Ulus SHEET 5 OF 6 EMIU CPM MMM aa �owowcEeo e1-e7W. n [Ym tEflER OTHER GLAZED DOOR PANEL/SIDELITE STYLES W/SURFACE APPLIED MUNTINS 36' ~I IF MAX ao 79 /16' II 00 1 ll oM�00 00 00 00 00 00 00 00 00 00 00 00 ao 00 PO -1 Po -2 PO -3 PI -4 PI -5 PO -6 PO -7 Po -1 PO -9 PO -10 PB -11 FIFE PO -13 PO -14 P!o-15 PO -16 Pp -11 p # I p g # , -M-, M7 1 , � -1, f 10, 16h-1 Q Fm --1 f lo,wo I imi IN ilmi IN] PO -IB Po -19 PO -20 PO -21 PO -22 PO -23 PO -24 P0-25 PI -26 P0-27 P0-29 Po -29 PO -30 PO -31 PO -32 PO -33 PO -34 88 0 iae as oa i� � IOU OUB 00 oa PO -40 PO -41 PO -42 Pa/3 PO -43A PO -428 Po -35 PO -36 PO -37 Po -3/ PI.39 36' 'I IMAX 79 1/171 MIX _ SL -10 1-a SL -31 51-60 1-50 • 1-5" 8 0 SL -69A 0 SL -691 0 1-690 1-25 SL -55 1-301 1-40 1-%A 1-901 1-900 1-303 SL -30C 1-10 1-01 APPRO=h5 CMMMM %IMM