Loading...
HomeMy WebLinkAbout105 E End CtPermit # Job Address: Description of Work: P�U L w 1 -t;—'total Square Footage Historic District: Zoning: ( vlllue of Work: Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool CITY OF S ANFORD PERINfIT APPLICATION eo —Qt c: 2— I— Olt- Addition/Alteration �OUJ Electrical: New Service — # of AMPS Mechanical; Residential Non -Residential — Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets — Occupancy Type: Residential Commercial Change of Service Temporary Pole _ Replacement New (Duct Layout & Energy Calc. Required) # of Water & Sewer Lines It of Gas Lincs Industrial Plumbing Repair — Residential or Commercial Construction Type: �J # of Stories: It of Dwelling Units; Flood Flood Zone: (FEMA form required !) Owners Name & Address: Cl �/5 �/t/L�G� CL'/� C Phone: Contractor Name & Address:�t ! �r,/�b� N '362 /���1 L 3 'T 7f7 7 State License Number: _[`K'4�y, `fit l 'lot Z1yrt �6C�o act Person: /�t�1 ✓J 1 (�Y �J�' Phone: �7 �� 7 Phone & Fax: _tu Bonding Company: Address: Mortgage Lender: _ Address: Architect/Engineer: Phonc: 11 'Z Address: I D.,C) rL Fax: 04 & Application is liereby made to obtain a permit to do the work and installations as indicated. 1 certify that n �vork or installation has commenced prior to the issuance ora permit and that all work will be perronned to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit ]trust be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, IIEA'fERS,'I'ANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that till work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE'I'0 RECORD A NOTICE OF COMMENCEMENT MAY RESULTIN YOUK PAYING TWICE: FOR IMPROVEMEN'I'S TO YOUR PROPERTY. IF YOU INTEND To OBTAIN FINANCING, CONSUL; I' WIT11 YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additio]lal permits required front other governmental entities such as wider otunaganeut districts, state agencies, or federal agencies. Acceptance of f emitis verificatioII notify the owner I property n a w] Sig] of Owner/A�ent Date t til Print caner Agent's N ane ^ Signature ofNotarylStatc of Hurida 'D/ate(,/ waY �v� Nola Puitli, "ate of Florida � `r; Rua J Purcell is M Commission DD408593 wud�/�geiiits XUllis:i4Ah2_t#.1_ib_w_n to Me o Produced ID APPROVALS: ZON1 ' c G d flL: FD USpecial Conditions: Rcv 03/2006 of the require] 'lits of Flori LiV FS V . 2t�'7 S 6 'rt ]re oft f 'onln or/Agent Date Prim/t CC9retractor/Agent s Name ry / '; — 9yv ignature of Nott -Stale of Florida Dale �,p:m Pv,, �Plotaty Public State of Florida Reed J Purcell t? My Commission D0408593 Con :Tele Agenlia4' Me or, i _Produccd�lDjy�'�"""�/T,�`d%.IP ENG: BLDG:_ Windows and doors that open into the swimming pool/spas area without a fence barrier to prevent direct access shall be protected in accordance with FRC R 4101.17.1.9 Equipotential Bondinq grid Shall be provided for the first 3 -feet of the perimeter of paved surfaces of swimming pools and spas. 2005 NEC Article 680.26(C). SCREEN ENCLOUSURE 48" HIGH CHILD SAFETY FENCE The residential swimming pool barrier and or its compliant safety components shall be in pace prior to filling of the pool. FRC R4101.17 ' Structural plan review is limited to a general survey for code compliance. No review is implied nor was taken to verify structural adequacy N 89" 56' 18" E 6U' i �T-6" UTI ITY EASEMENT- `I I Fi I SCREEN ENCLOUSURE DOORS TO BE SELF CLOSING AND SELF LATCHING 1 1 It. 4 in. r� 1 PDOLDAsS1GiV.iVAs'T r POOL EQUIPMENT ELECTRIC METER Code violations found during inspection are required to be corrected. Plan/permit issuance does not grant approval of a code violation. 2004 FBC109.1 NOTES: IF WATER SOURCE IS A PRIVATE WELL- PRE -FILTER WATER TO FILL POOL ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (u.l. listed) FROM POOL STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' MIN. AND 20' MAX, FROM POOL IF ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR PROPERTY GATES TO BE SELF CLOSING AND SELF LATCHING PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP @ 48 TIMES DIAMETER ESTABLISH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENCY, ALLOW MIN. 10' HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO POOL WATER. DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE POSITIVELY SLOPED FOR DRAINAGE PROVIDE WEEP HOLES AND DEWATERING PUMPS AND ANY OTHER METHODS NECESSARY TO PREVENT THE POSSIBILITY OF THE POOL FLOATING DUE TO HYDROSTATIC UPLIFT PRESSURE WHEN THE POOL IS EMPTY. BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TO ASSURE THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO THAT NO VOIDS EXIST PROVIDING A FIRM BEARING FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) THIS IS NOT A DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BREAKER LOCATE POOL RETURNS DOWN 18" MIN. BELOW THE POOL BEAM POOLDESIGNAET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: SrRUC'rURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) 'THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNi TE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A.T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. rl Or KAREN M.fRS 1000 E ATLA TIC B VD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 POOL AREA PLAN TITLE TOL.ER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scab: 1 in = 20ft. Oin. DATE 2/2/2007 PAGE 1 OF 4 WALKING ROOM— I 8" SCREEN BEAM i � --------------------------- FIRE — ---- -- ---------FIRE P11'� i 8 ft. 7 in. I +18" I I I I I I � I I i z I I � m I , Q i . I POOLDE,SIGiV. NL1' I, 1 I t I I CA 77 7v 1 l t I \ / I ` ' I CV �� PLANTER / t PLANTER I all ti , tI 2 J R 3-0 ; t -- - i i +18 gin 3' DEEP %�n R 5'-6,. –� 2 . 2 in. Q I N I \- 5'-6" DEEP I U. Y �ON �O ` Q 0lb � I R 9'-0" \ V' / 20" 5 ft. 5 in. , 1' 13 ft. 10 in. 91. 7 ft. 8 --- r 7 t I ' WALKIN ROOM 8" SCREE V BEAM I I ' t I 1 / \ / I RESIDENCE 1 IIEVIEWED PLANS CITY I I I z co C9 I m I POOLDESIGN.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@swirnmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B,C. 2) [HE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) -THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNI7E/SHO"TCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A,'T,S.M.•15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING To COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. KARE AKERS 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 LAYOUT PLAN TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scale: 1/4" = V-0" DATE 2/2/2007 PAGE 2 OF 4 .e - NOTE: ALL EMBEDDED ITEMS TO BE INSTALLED 1000 EAST ATLANTIC BLVD. PRIOR TO GUNITE: POMPANO BEACH FLA 33060 1. MAINDRAINS AND LINES Info@ swi rnm ingpool plan. corn 2. SKIMMER DESIGN PER FLORIDA BUILDING CODE 424.2 3. LIGHT NICHES 424.2.6.6 ENTRAPMENT PROTECTION FOR 4. RETURN LINES 5. CLEANING LINE 424.2.17 RESIDENTIAL SWIMMING BARRIER 6. SPA PLUMBING IF INSTALLED INSIDE WALL 7. BOND WIRE 6. WATER FEATURE LINES AND ANY OTHER THROUGH WALL LINES AND FIXTURES GENERAL NOTES: STRUCTURAL 2" RETURN LINES 2" WATERFALL LINE POOL LIGHT 1-1/2" VENT LINE 2" MAIN DRAIN LINE 2" UNDERPRESSURE LINE 2" SKIMMER LINE 2" CLEANER LINE I POOL i EQUIPMENT I I i I POOLDESIGNAET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@ swi rnm ingpool plan. corn CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM 'TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 6) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO kns.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B,C . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. r n //ff �� 4 C/e_ ve, ,p� KAREwlK S 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 PLUMBING PLAN TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scale; 1/4" = 1'-011 DATE 2/2/2007 PAGE 3 OF 4 POOL ELECTRICAL DETAIL TO SERVICE - G.F.I. OUTLET JUNCTION BOX -- locate 6" min, above water line. ALL ELECTRICAL TO COMPLY TO N.E.C, PER 2005 NEC (680.260 "EQUIPOTENTIAL 13ONDING GRIP"): 3' WIDE GRID OF SOLID COPPPER 48 AWG WIRE BURIED IN SAND, GRID SHALL BE 12" CIC WITH MAX SIZE SQUARE OF 16". COPPER CONDUCTORS SHALL BE •TERMINATED AT EACH CROSSING BY EXOTHERMIC WELDING, LISTED PRESSURE CONNECTORS, LISTED CLAMPS OR OTHER LISTED MEANS. SCREEN FOOTER DECK DETAIL. 36" X 8" STEM WALL �._IIIIIIII IIIII� STRUCTURAL DETAIL INTERLOCKING BRICK PAVERS -4--- BULLNOSE BRICK COPING SLOPE DECK 1/8" PER t ALL EQUIPMENT i COMPACTEDRLL.- rI _ 9— ~'- FOOT FROM POOL. t INSTALLED PER I lift �� r MANUFACTURER I �� SPECIFICATIONS 1p 3#3s CONT 18" MIN. FROM TOP I I 18" X 12" OF LIGHT TO FOOTER W/ WATERLINE 8"AntiVortex I SWITCHES—o. 1 2 #5 CONT. I _ i 1 i #8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BE / SecuredInIn P I — 3 #12s IN 1/2" I N CONDUIT I INSTALLED IN AT LEAST FOUR (4) LOCATIONS EQUALLY I - — — — -- — - So That Tool SPACED AROUND PERIMETER OF THE POOL OR SPA. ` �_�COAT BOND CONNECTION Required For #1 2sI----------------------------_- __---_-,-�W/ APPROVED POTTING 3 CON IN IT I min. 3" \ CONDUIT I 12V 1I8 AWG INSULATED COPPER / COMPOUND TRANSFORMER WIRE EPDXY COATED (IN LIGHTCORD CONDUIT) (IN CONDUIT) 300 WATT 12v REMOVABLE UNDERWATER UL LIGHT IME CLOCK WALLS ° o 6" FLOOR PEBBLE TEC ° OR 220v #8 AWG INSULATED COPPER POOL STEEL OVERLAP �-� DIAMOND MOND BRITE ° o 0 PUMP WIRE GROUND TO POOL @ 48 TIMES DIAMETER #3 STEEL @ 12' O/ m PLASTER FINISH Gravel Sump° MO TGR STEEL HORIZONTAL ° o VERTICAL PROVIDE 3" MIN COVER TO DIRT 1.51 IP AND 2" MIN. COVER TO WATER POOL PUMP ALL METALLIC ITEMS WITFI/N 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #6 SOLID INSULA TED WIRE (0. //sled) FROM POOL 8 AM P STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS......G.F.1. OUTLET 10' MIN. AND 20' MAX. FROM POOL ANTI -ENTRAPMENT POOL DETAIL ' A.- JUNCTION BOX :15'MINIMUM FROM WA'T'ER MINIMUM 11 DEGREES MAX. ANGLE FROM PLUMB \ 4'-0" POOLDESIGN.NGT 27'.0" s" FILTER DETAIL i 36" X 8" STEM WALL, 55 ppm STEEL REINFORCED Smooth Troweled ; Eiz 7r AND FILLED 1,5 HP CONCRETEBLOCK I i POOLPUMP 1-112" CV FILTER 95 qpni B AMP =n — 18 � I W/ 2 #5 CONT. _ 4` 75 GPM a I Removal z 325 S,F,- 76 LF ✓ y U, Uam� LU W FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION 1.5 1 3'•0" I � q o ¢wo STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) "f *� GRADE DEFORMED BARS OR NEW BILLET STEAL �zg i '. • �' VENT LINE PER PLAN STANDARDS AND SPECIFICATIONS. MAIN DRAINS TO HAVE ANSI / N ❑ ASME Al12.19.$M ANTI VORTEX MAIN DRAIN LINE 3 WAY COVER POOL MAIN DRAIN SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. ° � W VALVE �) 1000 E ATLANTIC BLVD o ° o LEss PER Fec 424 t115 SAFETY VACUUM RELIEF SYSTEM IS A NON•ECHANICAL POOL MAIN DRAINS TO BE VENT SYSTEM THAT WILL LIMIT THE Hydrostatic ValVe INSTALLED VAPART SMISSION OF SUCTION AT THE OUTLET TO A MAX. W/ WellPoint OF 4.; ' OF MERCURY o ° o TOLER RESIDENCE S 105 E END COURT z DATE 2/4/2007 (V m W N o wo > 3 WAY m z VALVE %0 N POOL N MAIN DRAINS D mmi �J , x C L 71 A � z r- r - r z Irl A.- JUNCTION BOX :15'MINIMUM FROM WA'T'ER MINIMUM 11 DEGREES MAX. ANGLE FROM PLUMB \ 4'-0" POOLDESIGN.NGT 27'.0" s" #3s 16" O/C i 36" X 8" STEM WALL, 55 ppm STEEL REINFORCED Smooth Troweled ; Eiz 7r AND FILLED I CONCRETEBLOCK I i Main Finish t LL 1-112" CV Be ' 95 qpni _ 18" X 12" FOOTER =n — 18 � I W/ 2 #5 CONT. _ 4` STERNI WALL DETAIL 6" CERAMIC TILE 0 42" R 0 12., 12 ! 7' m SLOPE OF POOL BOTTOM NOT TO EXCEED VIN 7' �Z ---- 8" ANTIVORTEX MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVAL HYDROSTATIC VALVE WITH WELLPOINT GRAVEL SUMP 3'-0" SHEAR DESCENT WATER FAIL VENT LINE TO BE 1ft MIN. ABOVE POOL WATER ANTI - ENTRAPMENT ................................ 11 drg maxi Shall PI SIZE i i 55 ppm iw Smooth Troweled ; Eiz 1.0 hp = 7v gpm Plaster Interior o 40 LF i Main Finish t LL 1-112" zz f Be ' 95 qpni 1.1/2" 6" Thick WallsW 2.5.hp = �I s Are ' z 62 LF a I Removal z 1.1/2" 76 LF ✓ y DECK OF SIMILAR SIZE AND DEPTH, IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 1 3'•0" I CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) "f *� GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A.T,S.M.-15. STEEL SHALL BE BENT, '. • �' VENT LINE PER PLAN STANDARDS AND SPECIFICATIONS. MAIN DRAINS TO HAVE ANSI / SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V,C, MIN. POOL PIPING TO COMPLY WITH F.B,C . POOL ASME Al12.19.$M ANTI VORTEX MAIN DRAIN LINE ARRANGED THAT THERE IS NO CROSS CONNECTION WITH COVER POOL MAIN DRAIN SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. ° ° ° DETAIL Threaded Plug -VENT IS UESIeNE0 TO EVACUATE SUCTION IN 3 SEC. OR g 1000 E ATLANTIC BLVD o ° o LEss PER Fec 424 t115 SAFETY VACUUM RELIEF SYSTEM IS A NON•ECHANICAL POOL MAIN DRAINS TO BE VENT SYSTEM THAT WILL LIMIT THE Hydrostatic ValVe INSTALLED VAPART SMISSION OF SUCTION AT THE OUTLET TO A MAX. W/ WellPoint OF 4.; ' OF MERCURY o ° o TOLER RESIDENCE PUMPING FLOW RATES 60 TDH HP FLOW RATE SIZE VENT PIPE MAX LENGTH 3/4 hp = 55 ppm -112' 29 LF 1.0 hp = 7v gpm 1-112" 40 LF 1.5 hp = 90 m 1-112" 49 LF 2.0 hp = 95 qpni 1.1/2" 51 LF 2.5.hp = 115 cgprn 1.1/2" 62 LF 2 150 gpm 1.1/2" 76 LF BASED UPON STA -RITE MAX -E -PRO SELF PRIMING PUMP 1/4" TAP CON BOLTS 4" THICK CONCRETE SLA[ 1/4" TAP CON BOLTS SWIN PIPE PRESSURE FLOWS CT10FLOW SIZE CAPACITY (10FPS) CAPACITY (SFPS) 1.5" 60 gpm 49 gpm 2.0" 100 ppm 80 ppm 2.5" 150 gprn t10 gpm 3.0" 220 gpinL0 qpm r-1 L 1 CAPTILE EDGE OF CONTRASTING COLOR EQUIPMENT ANCHORAGE DETAIL POOL SPECIFICATIONS 1000 EAST ATLANTIC BLVD. SUITE 100 LENGTH 27'-0" WIDTH 14'-0' MIN. DEPTH 3'-0" MAX. DEPTH INCLUDING BUT NOT LIMITED TO AREA 300 Sq. Ft. PERIMETER 72 Ft. GALLONS 9,300 TURNOVER RATE 1.9 HOURS INLETS 3 LIGHT(S) 300 W 12V PUMP 1.5 HP FILTER CARTRIDGE 325 S.F.- SKIMMERS 1 I MAIN DRAINS 2 POOLDESION.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpooiplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424,2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) -THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF, 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH, IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A.T,S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I, STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V,C, MIN. POOL PIPING TO COMPLY WITH F.B,C . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. /l 07 KAREN M. AKERS 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 I.E. 59993 DETAILS TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 DATE 2/4/2007 PAGE 4 OF 4