HomeMy WebLinkAbout1133 Rinehart RdCITY OF SANFORD PERMIT APPLICATION Application # : `� '� � j h �/ Submittal Date: Job Address: ' fl)Pha�� Rd . �Rl1r��rG] r �L�'! 0 Value of Work: $ 3� DOQ. �� MAR Parcel ID: /133 Zoning: historic District MAIL 1 r Description of Work: nC'.Y Square Footage: PermitType: ��� ype: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑�'r 5 n ir�ef�Alarm ❑� fool �❑ Sign �❑ Electrical: New Service —# of AMPS Addition/Alteration ❑ Change of Service ❑ Temporury Pole ❑ Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cala Rc(Iuircd) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lincs Plumbing/New Residential: # of Water Closets Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ Construction Type: # of Stories: # of Dwelling Units # of Gas Lines Plumbing Repair—Residential ❑ Commercial ❑ Occupancy Use Croup(s): Flood Zone: (FEMA form required) ...•t .' Property Owner: he P. •• ..D1��(ill••••••.......•••• •Contractor: -no P `�.%••• 1 ttl� tZ�1CG•'� v Address: ��q N �l�lMoi� oac! Sty k 2Dly � Address: �Ca 1 iw c! 3 AN61 3(A7 U0 Phone: E-mail: Cs��)5�7 3Q't`r7raycbol�7cara Phone: State License Number: Bonding Company: Mortgage Leuder: IM ( o• - Address Architect/Engineer: Address: Plan Review Contact Person: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify Umt ou work or installation has commenced prior to the issuance ora permit and that all worl< will be performed to meet standards of all laws regulating construction ill this jurisdiction. I understand (hit( it separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACE'S, BOILERS, I IUA'TE'RS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all or the foregoing information is accurate and that all wurk will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR WWROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER UR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE_: In addition to the requirements of this permit, there may be additional restrictions applicable to this property (hilt may be found in the public records or this county, and there may be additional permits required from other govornmontat entities such as water management distri(ts, state agcncics, or laderal agcncics. Acceptance of permit is verification that I will notit' the owner of the property of the rcquirearents or Florida Lien Law, FS 713. Signature of Owner/Agent Date iaturc of Contractor/Agent Date \.)ASAN 'tA, IM����t< Print Owncr/Agent's Name Print Coo Tactor/Agent's Name Signature of•Notary-State of Florida Date Signature of Notary -State orFlorida Date Owner/Agent k _ Produced ID AI'I'ROVALS: ZONING: Special Conditions: Rev 02/2007 I�q MY COMMISSION M DD62909G '8orreo,� EXf IRES: F'cbru�my25,2011 •nrv;iNornry FL Nuwry Uixw,nt Assn. Cu. Personally Known to Me or Coulrao74 lodAgeufis� v.t� e 'roduccd IU f UTIL: FD .: ... / -. ENG: BLDG: 1 o v :� 9 7.oC> INSTALLATION NOTES i l._. I. MT = DENOTES NEW TIE-IN TO EX15TNG PIPING: WITH MECHANICAL TEE 7.1 2. PLUG = DENOTES EXISTING OUTLET TO BE PLUGED IF NOT USED 3. SPRINKLER HEADS MAY 13E SPACE UP TO 9'-0" OFF ANY ONE WALL PER NFPA 13 8632.4 N ROOM THAT MEET THE REQUIREMENTS OF 3320 4. ALL EXISTING SPRINKLER HEADS PULL N I" X 1/2" BCI BUSHNG ALL EXISTING: OUTLETS ARE I' ( D� 7.5 7 g LEASE IMPROVEMNET PLAN / FIRE PROTECTION AMERICAN PIE PIZZA BRANCH FACILITIES RINENOLD ROAD - SANFORD, FLORIDA 8 SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" WET a SYMB. TYPE MAKE 8c MODEL SIN# ORIFICEI NPT K I TEMP. FINISH QTY. A/G FITTINGS BLACK -� EXISTING UPRIGHT, Q.R. - - 1/2" 1/2" 5.6 155' F BRONZE 28 $- NEW SEMI -RECESSED PENDENT, Q.R. RELIABLE T1 FR' R3615 1/2" 1/2" 5.6 155 F CHROME 30 W NEW DRY PENDENT, STANDARD, Q.R. RELIABLE DRY PEND R5714 1/2" 1" 5.6 155' F CHROME 2 Y ALIGNED IN ALL TYPICAL 2'x2' TILE DIRECT IONS WHEREVER POSSIBLE. Cr=NTrR OF TILE PETAL.. NOT TO SCALE D: o_ WET a PREFERRED HEADS CAN BE 1" +o 2" PIPE BLACK / sch 40 s o 0 Z I- BAILEY FIRE PROTECTION INC. B 5 4 STAT E F� OA ED , 0ROVELAND. FL 34736 DRY 2%* to 6" PIPE BLACK / sch 10 PRE -ACTION A/G FITTINGS BLACK DELUGE HANGERS STANDARD STEEL FOAM ATR and TBC STANDARD STEEL >_ ANTIFREEZE U/G PIPE D.I. CL50 STAND PIPE U/G FITTINGS M.J. OF TILE" U Tel. (352) 557-3049 1 Fax (352) 557-3049 IN ROOMS WITH - MULTIPLE HEADS, - - r TYPICAL GooSENECK DETAIL SCALE: N.TB. «EY �o Fire Protection Inc. TYPICAL 2'x4' TILE IN SMALLER ROOM PREFERRED HEADS CAN BE PORTION OF TILE INSTALLED IN ALL FOR SPRINKLER QUARTER POINTS HEAD PLACEMENT OF THE TILE UNDER THE DEFINITION "CEIJTER OF TILE" LK IN ROOMS WITH MULTIPLE HEADS, THEY WILL BE ALIGNED IN ALL TYPICAL 2'x2' TILE DIRECT IONS WHEREVER POSSIBLE. Cr=NTrR OF TILE PETAL.. NOT TO SCALE TOP BEAM C" r ZINC PLATED ALL THREAD RX 3/8" FOR 1"-4" Plf'E = 1/2" FOR 6" PIPE S16ER RIW3 1"-6" TOP BEAM CLAMP DANGER DETAIL M SCALE: V.S. 1 4 2 HOUR PENETRATION SEAL System No. W—J-1067 HILTI, INC. FS -ONE DETAIL IS SHOWN. F -Rating - 1 and 2 Hr (See Items 1 and 3) AN EQUAL FIRE STOPPING SYSTEM MAY T—Rating — 0 Hr BE USED AS LONG AS THE RATING OF L Rating At Ambient — Less Than 1 CFM/sq ft THE FLOOR / WALL IS MAINTAINED. L Rating At 400 F — 4 CFM/sq ft A 2 :}F^. 3 A NOTES. Section A -A 1_ GYPSUM BOARD WALL ASSEMBLY . 2. THRaIGH PENETRATE - ONE METALLIC PIPE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN FIRESTOP SYSTEM_ 3. FILL, VOID OR CAVITY MATERIAL - SEALANT - MIN. 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. At THE POINT OF CONTACT LOCATION BETWEEN THE THROUGH PENETRATE AND GYPSUM WALLBOARD, A MIN. 3/5" DIA. BAD OF FILL MATERIAL SHALL BE APPLIED AT THE GYPSUM WALLBOARD/THROUGH PENETRATE INTERFACE ON BOTH SURFACES OF WALL. SPECIFIED TECHNOLOGIES. NORTH REVISION DATE 0 3/12/07 REVISION DESCRIPTION ISSUE FOR PERMIT / APPROVALS GENERAL / OVERHEAD NOTES 1. FIRE PROTECTION SYSTEM DESIGN, MATERIALS, INSTALLATION, AND TESTING SHALL COMPLY WITH NFPA 13 (2002 ED_), AND ALL APPLICABLE STATE AND LOCAL CODES. 2. SPRINKLER HEAD5 ARE REQUIRED TO BE CENTERED IN ACOUSTICAL CEILING TILE. 3. ANY AND ALL PENETRATIONS IN FIRE/SMOKE WALLS SHALL BE FIRE AND SMOKE STOPPED WITH A LISTED ASSEMBLY. SEE DETAIL THIS PAGE 4, ALL PRODUCTS, PIPING, AND EQUIPMENT USED FOR FIRE PROTECTION WORK SHOWN ON THESE DRAWINGS SHALL BE UL LISTED AND BEAR SUCH MARKINGS, SEE MATERIAL SUBMITTAL DATA FOR PRODUCTS TO BE USED. 5. ANY SPRINKLER HEADS INSTALLED IN HARD CEILINGS SHALL BE PROTECTED BY A REMOVABLE HEAD COVER TO ENSURE HEAD 15 NOT DAMAGED DURING CEILING FINISHING PROCESS. 6. HANGER SPACING AND INSTALLATION SHALL CONFORM WITH NFPA 13 (2002 ED)_ i. ALL THREAD ROD SHALL BE ZINC PLATED_ 8. MATERIALS OF INTERNATIONAL ORIGIN MAY NOT BE USED_ 9. NO PAINTING, WIRING, OR PROVIDING OF FIRE EXTINGUISHERS IS REQUIRED OF THE CONTRACTOR. 10. ALL OUTLETS SHALL BE SHOP WELDED. TAPE AND PIPE DOPE SHALL BE USED AT ALL WELDED OUTLETS. 11. PIPE JOINT COMPOUND SHALL BE USED AT ALL THREADED CONNECTIONS. 12, ALL LENGTHS ARE CENTER TO CENTER U.N.O. 13, LIGHT HAZARD SPACING IN DINING AREA ORDINARY GROUP I SPACING IN KITCHEN AND STORAGE AREA_ 225* 50. FT MAX. SPAGING PER SPRINKLER HEAD 15'-0" MAX. DISTANCE BETWEEN HEADS I'-6" MAX_ DI5TANCE HEAD OFF ANY WALL** 6'-0" MIN. DISTANCE BETWEEN AND TWO HEADS. 4" MIN. DISTANCE HEAD OFF WALL. 130* SQ. FT MAX. SPAGING PER SPRINKLER HEAD 15'-0" MAX. DISTANCE BETWEEN HEADS i'-6" MAX. DISTANCE HEAD OFF ANY WALL 6'-0" MIN. DISTANCE BETWEEN AND TWO HEADS. 4" MIN. DISTANCE HEAD OFF WALL- ** PER NFPA 13 SECTION 8.6.3.2.4 AND HEAD MAY BE UP TO 9'-0" OFF AN" ONE WALL THAT MEET THE REQUIREMENTS OF 3.3.20, 14. NO CHANGES TO DESIGN CRITERIA OR REMOTE AREA EXISTING PIPE SIZES TO BE USED. EXISTING CRITERIA = ORDINARY GROUP II HAZARD .20 GPM DENSITY / 1500* SQ. FT. REMOTE AREA, NEW DESIGN CRITERIA DINING = .10 GPM DENSITY / 1500* ST. FT. REMOTE AREA, KITCHEN = .15 GPM DENSITY / 1500* ST, FT. REMOTE AREA. SCOPE: FF r> r — — — — DENOTES EXISTING SPRINKLER PIPING DENOTES NEW 5PRINKLER PIPING O DENOTE5 EXISTING SPRINKLER HEADS O ® DENOTES NEW SPRINKLER HEADS JMT DENOTES NEW MECHANICAL TEE TIED INTO EXISTING PIPING. /11 0PLW DENOTES EXISTING SPRINKLER OUTLET TO BE RELOCATE 23 HEADS ADDED 3 HEADS PLUG 0 HEADS DRAWN CHECKED v DAM JM -W, O Ir CL Z O F Q U 0 J REVISION 0 � gPrrJ ��W 0 „AR 1 9° PERMIT #j 411y__ AMERICAN PIE PIZZA 1125 - 1185 RINHOLD ROAD SANFORD, FLORIDA Fire Protection Plan SYSTEM NUMBER JOB NUMBER DRAWING No. 1 07-0012 FP -1