HomeMy WebLinkAbout1637 Rinehart RdILI REC51v5-D CITY OF SANFORD PERMIT APPLICATIORI EB 7007 !� Application H: _ s Submittal Date: 02/26/07 �% �"---}-�'.J _ , Job Address: 1637 Rinehart Rd Value of Work: $ $2,490.00 Parcel ID: 28-19-30-514-0000-0020 Zoning: Historic District: Description of Work: Add Fire Alarm Devices for Fedex Kinkos Tennant Build - Out Square Footage: _ ........................................................................................0bo............................. Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprink'r/Alam R1 Pool ❑ Sign 11Electrical: New Service — # of AN/IPS Addition/Alteration ❑ Change of Service"Temporary Pole ❑ Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Pixtures # of Water & Sewer Lines 1/ of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — LZcsidenlial ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEaNIA form required) ........................................................................................................................ Property Owner: Dikeor Realty LLC Contractor: LV SOIrtiOnS, Inc. _ Address: 1615 California St # 107, Denver CA 80202 Address: 106 Commerce Street STE 103 Lake Mary FL 32746 Phone: Bonding Company: Address: E-mail: Phone: 407-771-2020 State License Number: EF0000043 Mortgage Lender: Address: Architect/Engineer: Phone: ,,,,,,Address: Fax: Plan Review Contact Person: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations its indicated. 1 certify that no work or installation has commenced prior to tiro issuance of a permit and that all work will be performed to nice( standards of all laws regulating construction in this jurisdiction. 1 understand that a separate �-- permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, IWATERS, TANKS, and AIR CONDITIONERS, etc. ` >) OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done it compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE': TO RECORD A NOTICE; OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULTWITH YOUR LENL)ER Olt AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE;: In addition to the requirements of this emit, there may be additional restrictions applicable to this property that may be found in tits Public records of q P Y PP P P' Y Y this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or t'cderal agencies. Acceptance of permit is verification that L will notify the owner of the properly of the requirements of F rrf a Lien Law, FS 713. Cr'L Signature of Owner/Agent Date Signature of Contractor/Agent Dale Print Owner/Agent's Name Print Contractor/Agents Name Signature of Notary -State of Florida Date Signature NR ,y;,. a e EN �, pARON W �rx a * `4 Notary Public - State of j My Commission Expires Apr 46 Commission # DD 540�Bonded By National Notar j Owner/Agent is Personally Known to Me orC1. ntr actor/Agee Produced ID Produced ID APPROVALS: ZONING: UTIL: FD.ENG: BLDG: / I T Special Conditions: Rev 02/2007 ��~ BACK FLOW PREVENTER TAMPER SWITCH, ONLY IF IT REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION MONITOR MODULE — (SUPERVISORY ALARM) SEE KEYED NOTE T DUCT SMOKE DETECTORS i'UI TYPICAL FOR RTU CI,PRI V (2) HOUSE PHONE LINES IN 3/4"C TO TELEPHONE BOARD AHU SHUTDOWN 120V PLUS GRD. FROM HOUSE PANEL FIRE ALARM RISER DIAGRAM N.T.S. WATER GONG (WEATHER PROOF): BY OTHERS PROVIDE 120V FROM HOUSE PANEL 120 V, CIRCUIT SEPERATE FROM FACP OPERATION MATRIX FIRE PULL STATIONS SYMBOL MANUFACTURER DESCRIPTION MOUNTING INFORMATION FACP FARADAY MPC -6000 FIRE ALARM CONTROL PANEL TO' of Pka AT e' A.F.F. SMOKE DETECTOR FARADAY RDC -2 FIRE ALARM ANNUNCIATOR PANEL TOP OF PANG AT V-9' A.F.F. © FARADAY $700-S MANUAL STATION 4B' To TOP OF Box -- DEEP 19M W1 swore GANG aEVICE RING OR OLD WORK BOX DUCT DETECTOR FARADAY 8701 MINATURE MONITOR MODULE 4" SQUME BOX e FARADAY 8710 SMOKE DETECTOR V OCTAGON BOX BACKFLOW TAMPER BY OTHERS DUCT SMOKE DETECTOR PROMIDED AND wSrALLED BY MECNAFXCAL CONTRACTOR MONITORED BY FAM FOR ALARM AND 7ROUIRE. r-� t BY OTHERS BY OTHERS SPRINKLER FLOW MAIN BUILDING FLOW BY OTHERS BY OTHERS VALVE TAMPER Chi []K KNOX LOCK BOX MINIMUM B nXT BUILDING TAMPERS JUNCTION BOX Wv_ END OF LINE RESISTOR N cn BUILDING FLOWS FARADAY 28346-14-24 HORN STROBE 4' SQUARE BOX 51M TO K TED J FARADAY 270OB-14-24 STROBE 4' nwAK BOX Mw 7O 80' AFF ,N >% '+1 o oma- c �o o o��--0 z D O zD O O C a N o Tloc_a c�� cr�O/'� � �" I m �•� ^ wim d J U J 4 `..► .� `— N C Q a r - DEVICE DESIGNATION L1-1 Device number on Circuit Loop or Notification Circuit Number L -Addressable Device N -Notification Device 7 N6-3 A+g 75cd LI -119 2A+28 CN6-2 75cd e� E C E Ii zi WP NAC 7 rx LLI L113 G CLOSET \ Ia .. tc N� L1-125 A+B E ALL /SLC ACC I - J i U �n IA+28 �k"pug ALARM LEGEND SYMBOL MANUFACTURER DESCRIPTION MOUNTING INFORMATION FACP FARADAY MPC -6000 FIRE ALARM CONTROL PANEL TO' of Pka AT e' A.F.F. FRA -PI FARADAY RDC -2 FIRE ALARM ANNUNCIATOR PANEL TOP OF PANG AT V-9' A.F.F. © FARADAY $700-S MANUAL STATION 4B' To TOP OF Box -- DEEP 19M W1 swore GANG aEVICE RING OR OLD WORK BOX M FARADAY 8701 MINATURE MONITOR MODULE 4" SQUME BOX e FARADAY 8710 SMOKE DETECTOR V OCTAGON BOX =3 BY OTHERS DUCT SMOKE DETECTOR PROMIDED AND wSrALLED BY MECNAFXCAL CONTRACTOR MONITORED BY FAM FOR ALARM AND 7ROUIRE. r-� t BY OTHERS BY OTHERS SPRINKLER FLOW t �r BY OTHERS BY OTHERS VALVE TAMPER Chi []K KNOX LOCK BOX MINIMUM B nXT 0 JUNCTION BOX Wv_ END OF LINE RESISTOR N cn E14 FARADAY 28346-14-24 HORN STROBE 4' SQUARE BOX 51M TO K TED J FARADAY 270OB-14-24 STROBE 4' nwAK BOX Mw 7O 80' AFF NOTE: "E" NEXT TO DEVICE DESIGNATES THAT DEVICE AS EXISTING ( + I N4-3 I 15cd B N4-2 75cd �J r � L1-117 59 VA N7-1 �D 75cd WP p F K Ll-IUL A L1-01 2 A M L 1103 � 2 3 A � ML 104 FACP 1—�-�' M L 105 75cd N3-3 15cd sky rill E '2B I A N2-1 75cd B KEYED NOTES -1 Q FIRE ALARM CONTROL PANEL INSTALLED EITHER FLUSH OR SEMI FLUSH. O PROVIDE DEDICATED 120 VAC CIRCUIT FOR FIRE ALARM CONTROL PANEL, O ONE (1) j" CONDUIT WITH CABLES FOR CONNECTION TO TELEPHONE LINES FOR MONITORING. ® PROVIDE AND INSTALL KNOX BOX WITH TAMPER SWITCH CONNECTED TO FIRE ALARM SYSTEM. Q THESE UNITS ARE 1600 CFM AND DO NOT REQUIRE DUCT DETECTORS. Q DUCT DETECTORS ARE MONITORED BY ADDRESSABLE MONITOR MODULE. DETECTOR WILL REPORT TO FACP AS SUPERVISORY SIGNAL. O7 TAMPER SWITCH FOR BACKFLOW PREVENTER. COORDINATE WITH ARCHITECT FOR SITE LOCATION PRIOR TO ROUGH IN. GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL ADOPTED CODES 2. RACEWAY, POWER AND GROUNDING REQUIREMENTS SHALL COMPLY WITH APPLICABLE SECTIONS OF DEVISION 16. 3. MINIMUM RACEWAY SIZE SHALL BE J". 4. PROVIDE REMOTE INDICATION OF TROUBLES AND ALARM OF ALL DUCT SMOKE DETECTORS IN LOCATIONS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.. 5. COORDINATE SHUT -DOWN OF ALL MECHANICAL AIR SYSTEMS WITH DIVISION 15. 6. COORDINATE CONNECTION OF SPRINKLER WATERFLOW SWITCHES, TAMPER SWITCHES AND BACKFLOW PREVENTER VALVE TAMPER SWITCHES WITH THE SPRINKLER CONTRACTOR. SWITCHES ARE FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. PROVIDE CABLING, WIRING CONNECTIONS AND SUPERVISION TO ALL SWITCHES. 7. CONDUIT SHALL ENTER INTO THE FIRE ALARM PANEL ONLY IN ARES APPROVED BY THE EQUIPMENT MANUFACTURER. 8. ALL EXPOSED VERTICAL CABELING BELOW THE JOIST AND GIRDERS SHALL BE INSTALLED IN METALLIC CONDUIT, 9. ALL VISUAL NOTIFICATION CIRCUITS SHALL BE SYNCHRONIZED. 10. APPLICABLE CODES: NATIONAL FIRE ALARM CODE, NFPA 72, 2002 EDITION. OFFICE A]Rzhw'�Or WORK 19 \10 11 1 � 1 i - / 1 5' \ /� , WP Li -10 Y L1-102 N Q � _� /r �� ( LI -01L Y LI -103 I V O fI N5cd ` �II t e a LI -104 F-+ N5cd E r i Lt -105 ��� U_C, �� "y1 .. - L1.107 75cd N1-4 I T_ LL 4 -_I _---- ���A+6B ,rte = U z LLO zf—:< C\j rTu 4r1 i ij E O v) i I© S;�I I� ( c C e L1111 A B L1 -108A iB A+5B _ �— A+SB , — A -- I z w 1 ' a. DRAIMNG NO. SCALE: FA -101 1/4" = V-0" A+28 e�1 , DRAWN BY; DATE: C44 PERMIT #'iT. BLANC 02/22/07 APPROVED BY. DATE: D.DARWENT 02/22/07 by 891'atkartus, lnc� Low Voltage Systems Contractor N5cd E F 75 cd EF 0000043 U.L. 824158 1 106 Commerce Street, Suite 103 109 A+2B Lake Mary, Florida 32746 - - E u-uc>6 E - Phone: (407)771-2020 Fax: (407)771-2030 1 S EAL: REVIEWED � WIRE LEGEND SYMBOL USE DESCRIPTION A INITIATING 2 CONDUCTOR 18 AWG FPLR C MONITOR 2 CONDUCTOR 18 AWG FPLR D PIV 2 CONDUCTOR 14 AWG WEATHERPROOF E REMOTE INDICATOR 2 CONDUCTOR 22 AWG FPLR ( + I N4-3 I 15cd B N4-2 75cd �J r � L1-117 59 VA N7-1 �D 75cd WP p F K Ll-IUL A L1-01 2 A M L 1103 � 2 3 A � ML 104 FACP 1—�-�' M L 105 75cd N3-3 15cd sky rill E '2B I A N2-1 75cd B KEYED NOTES -1 Q FIRE ALARM CONTROL PANEL INSTALLED EITHER FLUSH OR SEMI FLUSH. O PROVIDE DEDICATED 120 VAC CIRCUIT FOR FIRE ALARM CONTROL PANEL, O ONE (1) j" CONDUIT WITH CABLES FOR CONNECTION TO TELEPHONE LINES FOR MONITORING. ® PROVIDE AND INSTALL KNOX BOX WITH TAMPER SWITCH CONNECTED TO FIRE ALARM SYSTEM. Q THESE UNITS ARE 1600 CFM AND DO NOT REQUIRE DUCT DETECTORS. Q DUCT DETECTORS ARE MONITORED BY ADDRESSABLE MONITOR MODULE. DETECTOR WILL REPORT TO FACP AS SUPERVISORY SIGNAL. O7 TAMPER SWITCH FOR BACKFLOW PREVENTER. COORDINATE WITH ARCHITECT FOR SITE LOCATION PRIOR TO ROUGH IN. GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL ADOPTED CODES 2. RACEWAY, POWER AND GROUNDING REQUIREMENTS SHALL COMPLY WITH APPLICABLE SECTIONS OF DEVISION 16. 3. MINIMUM RACEWAY SIZE SHALL BE J". 4. PROVIDE REMOTE INDICATION OF TROUBLES AND ALARM OF ALL DUCT SMOKE DETECTORS IN LOCATIONS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.. 5. COORDINATE SHUT -DOWN OF ALL MECHANICAL AIR SYSTEMS WITH DIVISION 15. 6. COORDINATE CONNECTION OF SPRINKLER WATERFLOW SWITCHES, TAMPER SWITCHES AND BACKFLOW PREVENTER VALVE TAMPER SWITCHES WITH THE SPRINKLER CONTRACTOR. SWITCHES ARE FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. PROVIDE CABLING, WIRING CONNECTIONS AND SUPERVISION TO ALL SWITCHES. 7. CONDUIT SHALL ENTER INTO THE FIRE ALARM PANEL ONLY IN ARES APPROVED BY THE EQUIPMENT MANUFACTURER. 8. ALL EXPOSED VERTICAL CABELING BELOW THE JOIST AND GIRDERS SHALL BE INSTALLED IN METALLIC CONDUIT, 9. ALL VISUAL NOTIFICATION CIRCUITS SHALL BE SYNCHRONIZED. 10. APPLICABLE CODES: NATIONAL FIRE ALARM CODE, NFPA 72, 2002 EDITION. OFFICE A]Rzhw'�Or WORK 19 \10 11 1 � 1 i - / 1 5' \ /� , WP Li -10 Y L1-102 N Q � _� /r �� ( LI -01L Y LI -103 I V O fI N5cd ` �II t e a LI -104 F-+ N5cd E r i Lt -105 ��� U_C, �� "y1 .. - L1.107 75cd N1-4 I T_ LL 4 -_I _---- ���A+6B ,rte = U z LLO zf—:< C\j rTu 4r1 i ij E O v) i I© S;�I I� ( c C e L1111 A B L1 -108A iB A+5B _ �— A+SB , — A -- I z w 1 ' a. DRAIMNG NO. SCALE: FA -101 1/4" = V-0" A+28 e�1 , DRAWN BY; DATE: C44 PERMIT #'iT. BLANC 02/22/07 APPROVED BY. DATE: D.DARWENT 02/22/07 by 891'atkartus, lnc� Low Voltage Systems Contractor N5cd E F 75 cd EF 0000043 U.L. 824158 1 106 Commerce Street, Suite 103 109 A+2B Lake Mary, Florida 32746 - - E u-uc>6 E - Phone: (407)771-2020 Fax: (407)771-2030 1 S EAL: REVIEWED � enferd Fire rev Div. MON o i © M © r ti 1 Chi a�CD M N cn Co 0 CU E J 2) LL LL ,N >% '+1 co Q) .,2' N to 0 8 2 ' N 1 ® CD E 2 �" I ILLOUj ^ wim d J U J 4 `..► .� `— N C Q a enferd Fire rev Div.