HomeMy WebLinkAbout1265 Upsala Rd (5)CITY OF SANFORD PERMIT APPLICATION
RECEIVED
Application # : 0� — ! 4 I I Submittal Date: ��3Z MAR O 2nn7
Job Address: 12 GS— Z,4P5A419- /Lo/4_0 , 1_C- Value of Work: $ '9_ %RZ�3 a y
Parcel ID: Zoning: Historic District:
Description of Work: Z7AU5'i✓tZL /2' /V/ 7z--,< Square Footage: _
........................................................................................................................
Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler/Alarm 8"�_ Pool ❑ Sign ❑
Electrical: New Service — # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑
Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair —Residential ❑ Commercial ❑
Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ Occupancy Use Group(s):
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required)
........................................................................................................................
Property Owner: SZQIVI u9G` lyi7�Gl %JyL�SL /%/�1L`NErL$
Address:e:.f1
32-771
Phone:
Bonding Company:
Address:
Architect/Engineer:
Address:
E-mail:
Plan Review Contact Person:
Contractor:l� Gc�+d' L (� SoGU i ICES 2VL
7
Address: S&,7Z !02
1_6 lfe 07//-/21/ 1--4- ZZ -7 4 6
Phone: 407 77/ 2caD State License Number: 2/-XCCC
Mortgage Lender:
Address:
Phone: Fax:
Phone:
Fax:
E-mail:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements ofiO6rida Lien w, FS 713.
7Z 7/
Signature of Owner/Agent Date Signature of Contractor/Agent ate
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Owner/Agent is _ Personally Known to Me or
_
Produced ID
APPROVALS: ZONING:
Special Conditions:
Rev 02/2007
UTIL: FD:
'T E
n ntrac gent' Na ie
i -off
Signature of Notary -State of Florida Date
o _ actor gent is _
ProducedlD
1 ENG:
ersonally Know to Me or
FROM
(TUE) FEB 272007
IF VST. 1 W,9/No.
6825185539 P 3
06/23/2006 11 ; 12 FAX 4072' ", +58
US11ST4p-N-NAV_
. j��,"��
1 002%009
FROM (TUE)FEB 27 2007 1F 'I/ST.14:59/No,6825185539 P 4
06/2312008 11:12 Fr1k 40790
966 USASTOR-A-WAY
STATE 40P PLt)MA
G0t7N' y OA o Amm
mn or Ll pry
YKa0.M�gear+e oaul�lff
m4iutrc,�N:oi.
n'rr.►o�++r� Cw
►r Vs�aarmnt+.a�+ocoree. 2
.� � 30Q6'Y►.OSt �'d!
fii�id., ria a X110
dirCMW
wok ,, pia iS3.`- t�', `t°�+i�q►� .
J
LCD DISPLAY FIRE ALARM CONTROL PANELS FA-300SERIES
Description
Mircom's FA -300 Series fire alarm control panels
consist of 6 and 12 zone models which are equipped
with a two line by 20 character back -lit LCD display,
numerical keypad and an integrated UDACT/Digital
Communicator. The FA -300 Series family also
includes remote LED and LCD annunciators as well
as remote relay modules.
The FA -300 Series panels are ideal for both new and
retrofit applications. Designed for small to medium
commercial, institutional and industrial occupancies,
these panels are powerful enough to meet today's
installation demands. The FA -300 Series panels are
configurable by the keypad for onsite programming
or by a PC for both onsite and remote programming.
Easy to install and simple to operate and configure, the
FA -300 Series panels enable the installer to configure
the system to meet their specific requirements.
The FA -300 Series panels are equipped with a 5Amp
power supply, 4 -wire resettable smoke power supply
(300mA max.), an interface for a Remote Trouble
Indicator (RTI) and an RS -485 interface for remote
LCD annunciators, LED annunciators and Remote
Smart Relay modules.
All FA -300 Series panels come complete with a red
door, black enclosure, durable CAT -30 lock and key
and space to mount up to 12 AH batteries.. Optional
trim rings are available for semi -flush mounting.
Features
Available in 6 and 12 zone models
• Integrated UDACT/Digital Communicator on select
models
• Equipped with 2 line by 20 character back -lit LCD
display and numerical keypad
• Front panel and PC programmable
• Remote upload/download capabilities
• Base panel is equipped with Class °B" (Style "B")
initiating circuits which may be configured as Class
"A" (Style "D") using a Class "A" converter module
• Initiating circuits may be configured as Alarm,
Verified Alarm, Waterflow Alarm, Sprinkler Alarm,
Latching or Non -Latching Supervisory, Monitor and
Trouble -Only
• Base panel is equipped with Class "B" (Style "B")
indicating circuitswhich may be configured as Class
"A" (Style"Z') using a Class "A" signal convertermodule
• Audible signals may be configured for Steady,
Temporal Code, California Code and March Time
• Indicating Circuits may be configured as Silenceable
or Non-Silenceable for both signals and strobes
• Built-in sync protocols for the following strobe
manufacturers: Mircom, Amseco, System Sensor,
Gentex, Faraday and Wheelock
• Relay contacts for Common Alarm, Auxiliary/Alarm
(Disconnectable), Common Supervisory and
Common Trouble
• Configurable Signal Silence Inhibit, Auto Signal
Silence and One -Man Walk Test
• Subsequent Alarm, Supervisory, and Trouble
operation
• RS -485 Interface for Remote LED Annunciators,
LCD Annunciators and Remote Smart Relay
Modules
• Interface for a Remote Trouble Indicator (RTI)
• Two event history logs comprised of a 200 event
alarm log for alarm related events and a 200 event
general log for all other events
• 5 Amp Power Supply
• Optional modules for additional internal relay circuits
and City Tie/Polarity Reversal
• Optional trim rings for semi -flush mounting
• Complies with UL 864 9th Edition requirements
CATALOG NUMBED
NOT TO BE USED FOR INSTALLATION PURPOSES.
Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models.
Features
Initiating Circuits
The FA -300 Series panels are equipped with Class
"B" (Style "B") initiating circuits. The initiating circuits
may be configured as Class "A" (Style "D") using an
ICAC -306 Class "A" converter adder module.
Each Initiating circuit may be configured for one of
the following modes of operation:
• Alarm (Without smoke detector verification)
• Verified Alarm (With smoke detector
verification)
• Waterflow Alarm (Water flow sensors)
• Sprinkler Alarm (Sprinkler flow sensors)
• Latching Supervisory
• Non -Latching Supervisory
• Monitor (non -latching input used mainly for
correlating to a relay circuit)
• Trouble -Only (for monitoring a trouble condition
from an external device)
i3 Series Protocol
The FA -300 Series panels have the i3 Series protocol
built-in. The panels support the two -wire i3 Series
smoke detectors (2W-13/2WT-13). These i3 series
detectors communicate with the FA -300 to provide
the following status information:
Open circuit trouble
This trouble indicates that loop is broken.
Communication trouble
This trouble indicates that there is a fault in the line or
the line is too noisy, the panel cannot communicate
with the devices.
Dirty device
This trouble indicates that one or more device on the
i3 zone is dirty.
Out of sensitivity
This trouble indicates that one or more device on the
i3 zone is out of sensitivity range and cannot detect
an alarm condition.
Freeze trouble
This trouble indicates that a device on the i3 zone has
detected a freeze condition, e.g. the temperature is
below 41'F / 5 °C (available only on model 2WT-B).
The built-in protocol removes the need for the 2W -
MOD Maintenance Module.
Indicating Circuits
The FA -300 Series panels are equipped with
equipped with Class "B" (Style "B") indicating circuits.
The indicating circuits may be configured as Class
"A" (Style "Z") using an OCAC-304 or OCAC-302
Class "A" signal converter adder module. The audible
signals may be configured for Steady, Temporal Code,
California Code and March Time.
Each of the indicating circuits may be configured for
one of the following modes of operation:
• Silenceable Signal
• Non-Silenceable Signal
• Silenceable Strobe
• Non-Sileneceable Strobe
The FA -300 has built-in sync protocols for the
following strobe manufacturers; Mircom, Amseco,
System Sensor, Gentex, Faraday and Wheelock.
UDACT/Digital Communicator
The FA -300 Series panels are equipped with a fully
integrated UDACT/Digital Communicator which allows
for the reporting of events to a monitoring facility. The
UDACT/Digital Communicator can be configured for
single or dual line operation and uses the Security
Industry Association (SIA) and Ademco Contact ID
protocols. The UDACT/Digital Communicator is
configured via the main display and keypad on the
main panel.
In addition to its reporting functions, the integrated
UDACT/Digital Communicator can be used to connect
to the FA -300 panel from remote computers for
uploading and downloading of configuration data. It
also allows for the viewing of the event history logs.
The FA -300 series panels have two event history
logs comprised of a 200 event alarm log for alarm
related events and a 200 event general log for all
other events.
The integrated UDACT/Digital Communicator can
be configured for either DACT or UDACT operation.
In DACT mode the Digital Communicator reports
common alarm, trouble and supervisory information.
In UDACT mode the Digital Communicator reports
point specific information.
NOT TO BE USED FOR INSTALLATION PURPOSES.
CAT. 5662
page 2of6
0
FA -300 Series LCD Version Models
FA-300-6DR Six Zone LCD Display Fire Alarm
Control Panel
The FA-300-6DDR is equipped with six Class "B"
(Style "B") initiating circuits and two Class "B" (Style
"Y") indicating circuits rated @ 1.7 Amps maximum.
(Total of 5Amps) One ICAC -306 Six Initiating Circuit
Class "A" Converter Modules may be used for Class
"A" (Style "D") wiring of the initiating circuits. One
OCAC-302 Two Indicating Circuit Class "A" Converter
Module may be used for Class "A" (Style "Z") wiring of
the indicating circuits. The cabinet will support up to
12AH batteries. The panel can be semi -flush mounted
with the optional FA-300TRB trim ring.
Dimensions
FA-300-6DR: 20"H x 14.5"W x 4.5"D
FA-300TRB: 22.5"H x 17"W
FA-300-6DDR Six Zone LCD Display Fire Alarm
Control Panel with UDACT/Digital Communicator
The FA-300-6DDR is equipped with six Class "B"
(Style "B") initiating circuits and two Class "B" (Style
"Y") indicating circuits rated @ 1.7 Amps maximum.
(Total of 5Amps) One ICAC -306 Six.lnitiating Circuit
Class "A" Converter Modules may be used for Class
"A" (Style "D") wiring of the initiating circuits. One
OCAC-302 Two Indicating Circuit Class "A" Converter
Module may be used for Class "A" (Style "Z) wiring
of the indicating circuits. The FA-300-6DDR has a
built-in UDACT/Digital Communicator and the cabinet
will support up to 12 AH batteries. The panel can be
semi -flush mounted with the optional FA-300TRB
trim ring.
Dimensions
FA-300-6DDR: 20"H x 14.5"W x 4.5"D
FA-300TRB: 22.5"H x 17"W
FA-301-12DDRTwelve Zone LCD Display FireAlarm
Control Panel with UDACT/Digital Communicator
The FA-301-12DDR is equipped with twelve Class "B"
(Style "B") initiating circuits and four Class "B" (Style
"Y") indicating circuits @ 1.7 Amps maximum. (Total
of 5Amps). One ICAC -306 Six Initiating Circuit Class
A Converter Module may be used for Class "A" (Style
"D") wiring of the initiating circuits. One OCAC-304
Four Indicating Circuit Class "A" Converter Module
may be used for Class "A" (Style "Z) wiring of the
Indicating circuits. The FA-301-12DDR has a built-
in UDACT/Digital Communicator and the cabinet
will support up to 12 AH batteries. The panel can be
semi -flush mounted with the optional FA-UNIV-TRB
trim ring.
Dimensions
FA-301-12DDR: 26"H x 1.4.5"W x 4.5"D
FA-UNIV-TRB: 28.5"H x 17"W
q ® CAT. of 6
NOT TO BE USED FOR INSTALLATION PURPOSES. page 3 3 Of 6
Remote Annunciators
RAM-30OLCDR Remote LCD Annunciator
The RAM-30OLCDR provides LCD remote annunciation
through a 2 line by 20 character LCD display. The RAM-
300LCDR provides control switches for System Reset,
Signal Silence, Fire Drill and Acknowledge as well as
a numeric keypad to access the menu functions. The
common control functions can be disabled on a per
function basis. The RAM-30OLCDR has LED indicators
for A.C. On, Alarm, Supervisory, Trouble and CPU
Fail. The RAM-300LCDR comes complete with a red
enclosure and a CAT -30 Lock and key.
SRM -312R Smart Relay Module
The SRM -312 provides twelve configurable relay
circuits, rated @ 28 VDC, 1 amp (resistive). Each
circuit can be configured as a Normally Open (N.O.)
or Normally Closed (N.C.) contact. Each relay is
equipped with an LED that is lit when the relay is
energized. The relays can be configured as relay
per zone (1 to 1), Common on Alarm, Common on
Supervisory or programmable for a logical or adjacent
zone configuration. An adjacent zone configuration
will turn on an adjacent zone when the configured
zone is active. A chaining configuration allows for
multiple relays to turn on. The SRM -312 is DIP switch
configurable and connects to the RS -485 bus. The
SRM -312R come complete with a red enclosure and
a CAT -30 lock and key.
111111ii, ' 0
RAM-208R/RAM-216R Remote LED Annunciators
The RAM -208R and RAM -216R provide 8 or 16 points
respectively of LED annunciation. Both models feature
bi-coloured LEDs which are auto -configurable for
either Alarm (red) or Supervisory (amber). The LED
annunciators have indicators for A.C. On, Common
Trouble and Signal Silence and control switches for
System Reset, Signal Silence, Lamp Test and Buzzer
Silence. The RAM -208R and RAM -216R are equipped
with a keyswitch which allows forenablirig and disabling of
the Common Control functions. Both models are available
in a red finish and mount in a 4 -gang electrical box.
RAM-1016/RAM-1016TZ Remote LED Annunciator
The RAM -1016 Remote LED Annunciator provides 16
points of LED annunciation. The RAM -1016 comes
standard with bi-coloured LEDs which are automatically
configured for eitherAlarm (Red) or Supervisory (Amber).
The RAM -1016 has indicators for A.C. On, Common
Trouble and Signal Silence and controls for System
Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal
Silence. In addition it allows for the control switches to be
disabled on a perfunction basis. The RAM-1016TZ has
the same features and provides individual trouble LEDs.
Both models mount in a BB -1000 series enclosure.
RTI -1 Remote Trouble Indicator
Mircom's Remote Trouble Indicator provides remote
annunciation of fire alarm troubles. The RTI -1 mounts.
onto a standard single gang electrical box.
NOT TO BE USED FOR INSTALLATION PURPOSES.
CAT. 5662
page 4 of 6
Adder Modules
ICAC -306 Six Initiating Circuit Class "A" Converter
Module
The ICAC -306 converts six Class "B" (Style "B" initiating
circuits on the FA -300 main board to Class "A" (Style "D")
circuits. The ICAC -306 is equipped with wire leads to
connect to the FA -300 main board. It mounts to the right
of the main board Class "B" (Style "B") initiating circuits.
Two ICAC -306 modules are required to convert all twelve
initiating circuits on an FA-301-12DDR series panel.
OCAC-304 Four Indicating Circuit Class "A"
Converter Module
The OCAC-304 converts four Class "B" (Style "Y")
indicating circuits on the FA -300 main board to Class
"A" (Style "Z") circuits. The OCAC-304 is equipped
with wire leads to connect to the FA -300 main board.
It mounts to the right of the main board Class "B"
(Style "Y") indicating circuits and is used with the
FA-301-12DDR series panels.
OCAC-302 Two Indicating Circuit Class "A"
Converter Module
The OCAC-302 converts two Class "B" (Style "Y")
indicating circuits on the FA -300 main board to Class
"A" (Style "Z") circuits. The OCAC-302 is equipped
with wire leads to connect to the FA -300 main board.
It mounts to the right of the main board Class "B"
(Style "Y") indicating circuits and is used with the
FA-300-6DDR series panels.
RM-306/RM-312 Relay Circuit Adder Modules
The RM -306 provides six configurable relay circuits, rated
@ 28 VDC,1 amp (resistive). The RM -312 provides twelve
Form C configurable relay circuits, rated @ 28 VDC,1 amp
(resistive). On both models each circuit can be configured
as a Normally Open (N.O.) or Normally Closed (N.C.)
contact. Each relay is equipped with an LED that is lit when
the relay is energized. The relays can be configured as
relay per zone (1 to 1), Common on Alarm, Common on
Supervisory or programmable for logical or adjacent zone
configuration. An adjacent zone configuration will tum on
adjacent zone when configured zone is active. Achaining
configuration allows for multiple relays to tum on.
rap
,r�
PR -300 Polarity Reversal/City Tie Module
The PR -300 provides outputs for city box and polarity
reversal applications. As a city tie module the PR -300
provides an interface between the control panel indicating
circuits and a master box. It provides off -premises signal
transmission for systems that must comply with NFPA
requirements for Auxiliary Protective Systems. As a
polarity reversal module the PR -300 provides an interface
between the control panel and a reverse polarity receiver.
It provides off -premises signal transmission for systems
that must comply with NFPA requirements.
ELRX-300 Active End -of -Line Resistors
The ELRX-300 are powersaving End -of --Line resistorswhich
eliminates the need foran additional battery cabinet or larger
batteries in orderto meetthe60 hourstandby requirement.
(Please refer to Battery Calculation Chart in manual for
more details.) The ELRX-300 can also be used when
larger batteries than can fit in the cabinet are required. The
ELRX-300 are available with or without a mounting plate.
NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5662
�� page 5 of 6
Specifications
AC Input
120VAC @ 60Hz
Standby Power
24VDC standby batteries
Charging Capability
4 to 12 AH
Current Consumption
Standby: 283mA
Alarm: 560mA
Indicating Circuits
Power limited / 24VDC unfiltered / 1.7A @ 49°C per
circuit. Maximum 5 Amps.
Ordering Information
Model Description
Aux supply (non resetable)
Power limited / 22.3VDC regulated / 500mA max
4 -wire smoke supply (resetable)
Power limited/22.3VDC regulated / 300mA max
Unfiltered supply (full wave rectified)
Power limited / 24VDC unfiltered / 1.7A max at 49°C
Auxiliary Relays (Common alarm/supv/trb/ and
auxiliary second alarm)
FormC / 28VDC / 1A max
Control Panels
FA-300-6DR Six Zone LCD Display Fire Alarm Control Panel
EA:_300=6DDRD Six Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator
FA-301-12DDR Twelve Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator
Remote Annunciators and modules
RAM-30OLCDR
Remote LCD Annunciator (Red enclosure)
RAM-30OLCDW
Remote LCD Annunciator (White enclosure)
RAM -208R
Eight zone Remote LED Annunciator
RAM -216R
Sixteen zone Remote LED Annunciator
RAM -1016
Sixteen zone Remote LED Annunciator
RAM-1016TZ
Sixteen zone Remote LED Annunciator with individual Trouble LEDs
SRM -312R
Remote Relay Module with red enclosure
RTI -1
Remote Trouble Indicator
BB -1001R
Red enclosure for RAM-1016/RAM-1016TZ
BB -1001S
Semi -Flush Stainless Steel Enclosure for RAM-1016/RAM-1016TZ
BB -1001 WPR
Red Semi -Flush Weatherproof Enclosure for RAM-1016/RAM-1016TZ
TH-101
Heater Kit for use with BB -1001 WPR
Adder Modules
U.S.A.
ICAC -306
Six Initiating Circuit Class "A" Converter Module
OCAC-304
Four Indicating Circuit Class "A" Converter Module
OCAC-302
Two Indicating Circuit Class "A" Converter Module
RM -306
Six Relay Circuit Adder Module
RM -312
Twelve Relay Circuit Adder Module
PR -300
Polarity Reversal/City Tie Module
ELRX-300
Active End -of -Line Resistor
ELRX-30OR
Active End -of -Line Resistor with red mounting plate
Accessories
U.S.A.
FA-300TRB
Black Semi -Flush Trim Ring for FA -300-6 enclosures
FA-UNIV-TRB
Black Universal Semi -Flush Trim Ring for FA -301-12 enclosures
FA -300 -DF
Dead Front for FA-300-6DR/FA-300-6DDR
FA -301 -DF
Dead Front for FA-301-12DDR
UIMA
Universal Programming Tool
BA -104
12 Volt, 4 Ah Battery - 2 pcs required per panel
BA -1065
12 Volt, 7.2 Ah Battery - 2 pcs required per panel
BA -110
12 Volt, 12 Ah Battery - 2 pcs required per panel
NOT TO BE USED FOR INSTALLATION PURPOSES.
AWL, RNK-0m 0
Canada
U.S.A.
25 Interchange Way
60 Industrial Parkway, PMB 278
Vaughan, Ontario L4K 5W3
Cheektowaga, New York 14227
Telephone: (905) 660-4655
Toll Free: (888) 660-4655
Fax: (905) 660-4113
Fax Toll Free: (888) 660-4113
Web page: http://www.mircom.com Email: mail@mircom.com
Distributed by:
�y CAT.2
%aat,7�
Rev. 2
PHOTOELECTRIC SMOKE DETECTORS i3 SERIES
Description
The i3TM series smoke detectors represent a significant
advancement in conventional detection. The i3 family is
founded on three principles: Installation Ease, Intelligence,
and Instant Inspection.
Installation Ease
The i3line redefines installation ease with its plug-in design.
This allows an installer to pre -wire the bases included with
the heads. The large wire entry port and in-line terminals
provide ample room for neatly routing the wiring inside
the base. The base accommodates a variety of back box
mounting methods aswell as direct mounting with drywall
anchors. To complete the installation, i3 heads plug-in to
the base with a simple Stop -Drop 'N Lock action.
Intelligence
i3 detectors offer a number of intelligent features to
simplify testing and maintenance. Drift compensation
and smoothing algorithms are standard with the i3 line,
to minimize nuisance alarms. When connected to the
2W-MOD2 loop test/maintenance module, or a panel
equipped with the i3 protocol, 2 -wire i3 detectors are
capable of generating a remote maintenance signal when
they are in need of cleaning. This signal is indicated via
an LED located at the module and the panel. To read the
sensitivity of i3 detectors, the SENS-RDR is a wireless
device that displays the sensitivity in terms of percent per
foot obscuration.
Instant Inspection
The i3 series provides wide angle red and green LED
indicators for instant inspection of the detector condition,
indicating: normal standby, out -of -sensitivity, alarm, or
freeze trouble conditions. When connected to the 2W-
MOD2 loop test/maintenance module or a panel with
the i3 protocol, the EZ Walk loop test feature is available
on 2 -wire i3 detectors. This feature verifies the initiating
loop wiring by providing LED status indication at each
detector.
Features
• Plug-in detector line — mounting base included
• Large wire entry port
• In-line terminals with SEMS screws
• Mounts to octagonal and single -gang
backboxes, 4 -square backboxes, or direct to ceiling
• Stop -Drop 'N Lock TM attachment to base
• Removable cover and chamber for easy cleaning
• Built-in remote maintenance signaling
• Drift compensation and smoothing algorithms
• Simplified sensitivity measurement
• Wide angle, dual color LED indication
• Loop testing via EZ Walk feature
• Built-in test switch
Engineering Specifications
Smoke detector shall be an i3 Series model listed to
Underwriters Laboratories UL 268 for Fire Protection
Signaling Systems. The detector shall be a photoelectric
type (model 2W -B, 4W -B) or a combination photoelectric/
thermal (model 2WT-B, 4WT-B) with thermal sensor rated
at 135DF (57.2°C). The detector shall include a mounting
base for mounting to 3'/ -inch and 4 -inch octagonal, single
gang, and 4 -inch square back boxes with a plaster ring, or
direct mount to the ceiling using drywall anchors. Wiring
connections shall be made by means of SEMS screws.
The detector shall allow pre -wiring of the base and the
head shall be a plug-in type. The detector shall have a
nominal sensitivity of 2.5% per foot nominal as measured
in the UL smoke box. The detector shall be capable of
automatically adjusting its sensitivity by means of drift
compensation and smoothing algorithms. The detector
shall provide dual color LED indication which blinks to
indicate power up, normal standby, out of sensitivity, alarm,
and freeze trouble (model 2WT-B, 4WT-B) conditions.
When used in conjunction with the 2W-MOD2 module, 2 -
wire models shall include a maintenance signal to indicate
the need for maintenance at the alarm control panel, and
shall provide a loop testing capability to verify the circuit
without testing each detector individually.
Tamper -Resistant Feature
DIRECT MOUNT
HOLES
0
SNAP OFF TA
FOR TAMPER
TAMPER
RELEASE TAB
U `O•
L MEA
approved
MSFM F M
approved APPROVED
CATALOG NUMBER
5128
NOT TO BE USED FOR INSTALLATION PURPOSES.
Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models.
Wiring Diagrams
2W -B and 2WT-B Wiring Diagram
2 -WIRE +
Green -LED
Red LED
ZONE
M-IOUZ00000
Normal (standby)
Blink every 5 secs
f
Out of sensitivity
— — y2-WIREba
Blink every 5 secs
Freeze trouble
abCONTROLO
Blink every 10 secs
PANEL
S2W-B
Solid
V4.B
OR
1-WIRE
t4WT-B
2Wr-B
Electrical Specifications
Operating Voltage
Nominal: 12/24 V non -polarized
Min.: 8.5 V
Max.: 35 V
Maximum Ripple Voltage
30% of nominal (peak to peak)
LED Modes
4W -B and 4WT-B Wiring Diagram
AU OR
SMOKE
POWER
Green -LED
Red LED
IDC
Blink every 10 secs
Normal (standby)
Blink every 5 secs
off
Out of sensitivity
off
Blink every 5 secs
Freeze trouble
off
Blink every 10 secs
Alarm
off
Solid
V4.B
1-WIRE
t4WT-B
SENS-RDR
CONTROLPANEL
A77-AB2
i3 Series Retrofit Adapter Bracket
RT
Standby Current
2 -wire: 50 NA maximum average
4 -wire: 50 NA maximum average
Maximum Alarm Current
2 -wire: 130 mA limited by control panel
4 -wire: 20 mA @12V, 23mA @ 24V
LED Mode
Green -LED
Red LED
Power up
Blink every 10 secs
Blink every 10 secs
Normal (standby)
Blink every 5 secs
off
Out of sensitivity
off
Blink every 5 secs
Freeze trouble
off
Blink every 10 secs
Alarm
off
Solid
Physical Specifications
Operating Temperature Range
2W-13 and 4W -B:
32°F -120°F (0°C -49°C)
2WT-B and 4WT-B:
32°F -100°F (0°C -37.8°C)
Operating Humidity Range
0 to 95% RH non -condensing
Thermal Sensor
135°F (57.2°C) fixed
Freeze Trouble
2WT-B and 4WT-B only: 41 °F (5°C)
Sensitivity
2.5%/ft. nominal
Input Terminals
14-22 AWG
Dimensions (including base)
5.3 inches (127 mm) diameter
2.0 inches (51 mm) height
Weight
6.3 oz. (178 grams)
Peak Standby Current
2 -wire: 100 NA
4 -wire: n/a
Alarm Contact Ratings
2 -wire: n/a
4 -wire: 0.5 A @ 30V AC/DC
Power Up Sequence for LED Indication
Condition- Duration,-
Initial LED status indication 80 seconds
Mounting
3% -inch octagonal back box
4 -inch octagonal back box
Single gang back box
4 -inch square back box with a
plaster ring
Direct mount to ceiling
Ordering Information
U.S.A.
Model Number
Thermal Wiring Alarm Current
Vaughan, Ontario L4K 5W3
27w=B
No 2 -wire
130 mA max. limited by control panel
2WT-B
Yes 2 -wire
130 mA max. limited by control panel
4W -B
No 4 -wire
20 mA @ 12V, 23mA @ 24V
4WT-B
Yes 4 -wire
20 mA @ 12V, 23mA @ 24V
Accessories
2W-MOD2
i3 Series 2 -wire loop test/maintenance module
SENS-RDR
i3 Series Sensitivity Reader
A77-AB2
i3 Series Retrofit Adapter Bracket
RT
i3 Series Removal/Replacement Tool
I
j NOT TO BE USED FOR INSTALLATION PURPOSES.
11111k, MIRE; M0
Canada
U.S.A.
25 Interchange Way
60 Industrial Parkway, PMB 278
Vaughan, Ontario L4K 5W3
Cheektowaga, New York 14227
Telephone: (905) 660-4655
Toll Free: (888) 660-4655
Fax: (905) 660-4113
Fax Toll Free: (888) 660-4113
Web page: http:ltwww.mircom.com Email: mail@mircom.com
CAT. 5128
Rev. 3
METAL ` ALARM.
AC ,1'. O 0 Oi SERIES
. - - -•._. 6 ,.. t .. . �.:�... kb -. ^+ �ea6�4ar � .. ' :;-.w � .r •.,e y '«[_.. dt .tlY:.dn.l'9,:. -§p, - -
-
MS -701 U
Single Action Pull Station
Description
MS -71 OU
Dual Action Pull Station
Mircom's MS -7000 Series Manual Pull Stations provide
manual fire reporting. These high quality, die-cast metal
pull stations are available in either single or dual action.
configurations with SPST contacts and terminal strip
connections. The normally open contact, which closes
when the pull station is activated, is rated for 1 amp,
30 VDC. The contacts are gold plated to avoid the risk
of corrosion.
The MS -7000 Series Pull Stations are available in
many different configurations as either single or dual
action devices.
The MS -701U is a single action, single stage pull
station. Model MS -710U is a single stage, dual action
pull station.
All models are available with key resets; terminal
connectors, SPST gold contacts and CAT -30 lock
and keys. The units mount on a standard single gang
backbox, Mircom's BB -700 surface metal backbox or
BB-70OWP weather proof backbox.
Features
• Single or Dual Action
• Key resettable
• Terminal connectors
• Gold plated SPST contacts
• Optional auxiliary contacts
• High -gloss red enamel finish
• Plastic breakrod
• Mounts on standard single gang box, Mircom's
BB -700 surface metal backbox or BB-70OWP
weather proof backbox
Operation
The MS -701 U SingleAction Pull Station is operated by
pulling down the handle marked "PULL HANDLE" on
the front of the station. The MS -710U Dual Action Pull
Station is operated by pushing the bar labelled "PUSH
BAR" and then pulling down the handle marked "PULL
HANDLE". The MS -7000 Series Pull Stations are reset
by opening the station with the key, placing the handle in
the normal upright position and re -locking the station.
Specifications
The manual pull station shall be Mircom's MS -7000
Series. Operating instructions shall be in raised
English lettering and the unit shall be constructed of
high quality die-cast metal and finished in red enamel
paint to provide quick identification. Pulling the handle
shall initiate immediate operation of the alarm detection
circuit. All manual fire alarm stations shall be installed
as per the specific requirements outlined in the UL
codes, as well as all other applicable national or local
codes. Final acceptance is subject to the local authority
having jurisdiction.
S7005 S7005 7150-1477:128
CATALOG NUMBER
5157
NOT TO BE USED FOR INSTALLATION PURPOSES. -
Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models.
Specifications
Switch Rating:
Pull Station Dimensions:
Color:
Surface Mount Backboxes
1 Amp @ 30 VDC
0.1 Amp @ 125 VAC
4.9" H x 3.5" W x 2.0° D
Red with raised white letters, white pull bar with raised black letters.
BB -700 Surface Mount
Backbox
Dimensions:
5" H x 3.6" W x 2.0" D
Typical Wiring Diagrams
MS -701 U, MS -702U and MS -7100
FROM r ) TO NEXT STATION
PREVIOUS (t f OR END OF LINE DEVICE
STATION
FROM ( TO NEXT STATION
PREVIOUS I y OR END OF LINE DEVICE
STATIONI I MS -702U ONLY
MS -702U ONLY
N,O.KEYSWITCH NOTES:
MS702U ONLY -
1. WIRE AS SHOWN SO THAT SUPERVISION
OF CONNECTIONS IS MAINTAINED.
2. MOUNT STATION TO 2'x 4"x 2 1/4' OUTLET BOX.
3. SWITCHRATING: ALL MODELS 1A @ 30VDC,
0AA 0125VAC
N.O. SWITCH 4, MAXIMUM WIRE SIZE: No. 12 AWG.
Ordering. Information
FROM
PREVIOUS
STATION
BB-70OWP Weatherproof
Surface Mount Backbox
Dimensions:
5'H x 3.6"W x2.2"D
MS -701 UP and MS -71 OUP
Model
U
Description
CiA- ..0-
Single Action Manual Pull Station
MS -702U
Dual Stage Single Action Manual Pull Station
MS -705U
Single Action Manual Pull Station c/w one additional Form "C" (SPDT) Contact
MS-71OU
Dual Action Manual Pull Station
MS -715U
Dual Action Manual Pull Station c/w one additional Form "C" (SPDT) Contact
MS -701 UP
Single Action Manual Pull Station c/w pig tail leads
MS-710UP
Dual Action Manual Pull Station c/w pig tail leads
MS -701 NY
Single Action Manual Pull Station (New York Version)
MS-71ONY
Dual Action Manual Pull Station (New York Version)
BB -700
Series 700 Interior Surface Mount Backbox, Red Finish
BB-70OWP
Series 700 Weatherproof Surface Mount Backbox, Red Finish
NOT TO BE USED FOR INSTALLATION PURPOSES.
1 ' �Milk A@ Distributed by:
<<<<
Canada
U.S.A.
25 Interchange Way
60 Industrial Parkway
Vaughan, Ontario L4K 5W3
Cheektowaga, New York 14227
Telephone: (905) 660-4655
Toll Free: (888) 660-4655
Fax: (905) 660-4113
Fax Toll Free: (888) 660-4113
I
Web page: http:/twww.mircom.com Email: mail@mircom.com
L
t TO NEXT STATION
f OR END OF LINE
DEVICE
CAT. 5157
Rev. 2.
FA300 BATTERY CALCULATIONS
PANEL ID: FACP
Device
Number
Of Devices
Stand-by Alarm
Current (mA) Current
Stand-by
Total (mA)
Alarm
Total mA
FA300-6DDR
1
142 312
142
312
RM -312
0
0 160
0
0
RM -306
0
0 80
0
0
RAM -208
0
35 90
0
0
Auxiliary ��
Total Current
142
312
Devices ImAI
2W-13 Smoke Detector Mon. W."..
0
0 0
NAC CKT 2 0
0
0 0
NAC CKT 3 0
0
0 0
NAC CKT 4 0
0.
0 0
Total Notification Circuit Current - Must Not Exceed 8 Amps (Amps).
0 0
Auxiliary ��
Notification Circuits ISee Attached for a list of devices on each circuit and load calculations.
NAC CKT 1 0
0
0 0
NAC CKT 2 0
0
0 0
NAC CKT 3 0
0
0 0
NAC CKT 4 0
0.
0 0
Total Notification Circuit Current - Must Not Exceed 8 Amps (Amps).
0 0
Total Standby Current (Amps)
Number of standby hours
Total Stand-by AH
Total Alarm Current (Amps)
Alarm Hours
Total Alarm Hours
Total stand-by and Alarm AH
Safety factor of 20%
(5 minutes = .0833 hours)
3.44
4.13 Am Hours
CITY OF SANFORD FIRE DEPARTMENT
FEES FOR SERVICES
HONE # 407-302-2516 . FAX # 407-302-2526
DATE: PERM #:
BUSINESS NAME / PROJECT:-7,&CQ—A
4�1
ADDRESS:
,PHONE NO.: r7`7, -+ a5 0 FAX NO.:
CONST. INSP. O C / O INSP.:[ ] REINSPECTION [ J PLANS REVIEW [ 1
F. A. [) F:S. [ ] HOOD [) PAINT BOOTH [ 1 BURN PERMIT [ ]
TENT PERMIT k 1 TANK PERMIT [) OTHER ( ]
TOTAL FEES: $ (PER UNIT SEE BELOW)
COMMENTS: YYl
Address / Bldg. # / Unit # Square Footage Fees per Bldg. / Unit
1.
2.3."--
4.
5. -
6:
7.
8. i
9.
10.
11. _
12.
13, -- —
14.
15.
16.
17,
18.
19.
20.
Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407-
330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take
place. I certify that the above is true and correct and that l
will comply with all applicable codes and ordinances
of the City of Sanford, Florida.
Sanford Fire Prevention Division Applicant's Signature