Loading...
HomeMy WebLinkAbout1637 Rinehart Rd (2)Il 101-�r RECEIVED I " l� CITY OF SANFORD PERMIT APPLICATION FEB 2 7 2007 Application # : ()1— r Submittal Date: 02/26/07 Job Address: 1637 Rinehart Rd Value of Work: $ $2,490.00 Parcel ID: 28-19-30-514-0000-0020 Zoning: Historic District: Description of Work: Add Fire Alarm Devices for Fedex Kinkos Tennant Build - Out Square Footage: ........................................................................................ ............................. Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprink Alar 0 Pool 13 Sign ❑ Electrical: New Service — # of AMPS Addition/Alteration 13 Change of Service Temporary Pole ❑ Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines Plumbing/New Residential: # of Water Closets Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ # of Gas Lines Plumbing Repair —Residential ❑ Commercial ❑ Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) ........................................................................................................................ Property Owner: Dikeou Realty, LLC Contractor: LV Solutions, Inc. Address: 1615 California St # 107, Denver CA 80202 Address: 106 Commerce Street, STE103 Lake Mary FL 32746 Phone: Bonding Company: E-mail: Phone: 407-771-2020 State License Number: EF0000043 Address: Arch itect/Engineer: .,,,Address: Plan Review Contact Person: Mortgage Lender: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. r<) OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of F Lien Law, FS 713. v �'�r_ Al , &Z — Z,/, Signature of Owner/Agent Date Signature of Contractor/Agent Date Print Owner/Agent's Name Print Contractor/Agent's Name Signature of Notary -State of Florida Date Signatuie Noy,; a EN J.DVOEtrn Notary Public - S 'P4 ComnussiOn Ex0Commission Bonded By Natio. Owner/Agent is _ Personally Known to Me or Obntractor/Agen is o _Produced ID Produced ID 4410) APPROVALS: ZONING: UTIL: FD: I �: ENG: BLDG: f .f Special Conditions: Rev 02/2007 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: BUSINESS NAMI/ PROJECT: Fe— ADDRESS: PHONE NO.: FAX NO.: INSP. [ ] C / O INSP.:( ] REINSPECTION [ ] PLANS REVIEW F. A. U F. S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN P T [ J IT ], TANK PERMIT (] OTHER V TOTAL FEES: $ ' � (PER UNIT SEE BELOW) 11 �l Address / Bldg # / UnSquare Footage Fees per Bldg. / Unit L _ 2. 1163. --' 4. 5.6. �� 7. 8. 9. 10. 12. _ 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanford Fire Pr on Divis Applicant's Signature THIS INT UM N� T PREPARED BY: Building & Fire Inspection Name: t f\j-U(''}1 Dn `� i f K' 1101 East First dress: ICL Cf�57- 'RF 5Q r . Sanford, Florida 32771 SEMINOLE COLYIYT'Y State of Florida fLoatnwSNATURALcaarcE County of Seminole NOTICE OF COMMENCEMENT Parcel t0 Number (PID) 'Z$- tCj ]�� — j L} — 600 0 — 00 ZZ The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPRRTY (Legal description of the property and street address) 1051 Kine bard E Iq 'Fec1EX 1G NK n5 `30SNKD � I n•t- t'�, ,1 R, m n(X Qt m4tw-l- ?-I) L.f- lSi S 4A +Sn GENERAL DESCRIPTION OF IMPROVEMENT �hiPrIC>>' ��Ullh-OU� OWNER INFORMATION�pp—t"L Name and address: I) 114�oU f�1= PWf4 : llc.l5 CptLl ffbC (A '5�. � CONTRACTOR Name and address: fes) C&A1 rUl rt .1r—1 PISS, Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name and address: In addition to himself, Owner Designates _.. .. of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(6), Ftorlds Statutes: Expiration Date of Notice of Commencement Rhe exoiration date Is 1 vear from date of recordina unless a different date is-Nsoeeified.l STATE OF Q4W-a 00 COUNTY OF Signature WoWr The foregoing instrument was acknowledged before me this '2.3"—day of Z0-0— by 0_.by Who is personally known t me t� Name of person making statement OR who has producWo on type of identification produced ®'`,' O Notary Signature 'EOE z d 60HM90 '00/ :91 UAS:91 LORI (ins) MIMS N0113 HISNO0 ' 1UH ROU Features • One intelligent Signaling Line Circuit • SLC loop supports up to 252 addressable Inputs AND signal/relay outputs (504 inputs/outputs total) • Addressable devices are polarity insensitive • Devices operate on standard wire -no twist or shield required • FireSmart Application Specific fire detection • 4 Class B/2 Class A notification appliance circuits • Up to 6A NAC Power • Built in strobe synchronization protocol • 80 Character backlit LCD display • Optional Peer -to -Peer networking using MPC -Net • One man walk test (Silent orAudible) -Auto Program Feature • UP to 16 remote LCD Displays with control capabilities • Programmable from front keypad, or Windows based PC programming software • Maintenance and technician level passwords • Optional internal DACT • 2000 event history log • Made in the USA, ISO 9001 quality crafted • @ UL 864, MEA & CSFM Listed and FM Approved Description The MPC -6000 is an advanced modular fire alarm panel. It features analog/addressable detection, programming, and memory capability. It's base configuration includes one analog/addressable loop, with four notification appliance output circuits. Operating controls and indicators are mounted behind a locked cabinet door and an 80 -character LCD display provides specific indications for addressable devices, while LEDs indicate general panel status. E')(1 S 7 -IA)G MPC -6000 Hardware Configuration The main termination board mounts in the rear of the panel.The main power supply is physically contiguous with the main termination board.The MPC -6000 main termination board provides the interface for external system connections, the SLC loop interface PCB, four NAC circuits, remote signaling circuits and indicating interfaces. The front Display Board mounts on a hinged front plate, which is located behind a locked cabinet door. Displays for any number of zones are handled through this board. All normal operation is controlled from the front of the panel via membrane switches. Displays are provided by an 80 -character, alphanumeric, backlit LCD display and by discrete LED indicators for major panel functions. Dimensions MPC 6000 Single Loop Addressable Fire Alarm Panel, Red BOX 18" DOOR 18 3/8'. BOX 22" DOOR 22 9/32° Ordering Information N 51/4" 7ompptc, MPC 6000 Single Loop Addressable Fire Alarm Panel, Red 599 049304FA MPC -6000 Single Loop Addressable Fire Alarm Panel, Black 599-049303FA RDC -2 Remote Annunciator 500-648980FA NPE-1 Transformer to expand NAC power 500-649120FA SRU -2 RS -485 Relay Card 500-649308FA SRE-8 8 Relay Extender 500-649337FA SLU-2 RS -485 LED Driver Card (16 Outputs) 500-649307FA SLE -16 16 LED Driver Extender 500-649339FA FAE-21 ACC. Enclosure for RS -485 Devices 500-401403014FA MPC-DACT Dialer for MPC -6000 and MPC -7000 500-649330FA CT -1K CityTie Module for MPC -6000 and MPC -7000 500-649336FA SFTK-6R Semi-FlushTrim for MPC -6000, Red 500-648955FA SFTK-6B Semi-FlushTrim for MPC -6000, Black 500-648954FA 1111 'AlL 11=111 Siemens Building Technologies, Inc. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (973) 593-6670 Web: www.faradayfirealarms.com WARNING -The information contained in this document is intended only as a summary and is subject to change without notice.The devices described in this document have specific instruction sheets which cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations Document, which also contains important information, are provided with the product and are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. 11/06 2M SBT/IG November 2006 - Supersedes sheet dated 11/04 Features *The AdapterTM feature offers four field selectable candela values— 15/75,30/75,75or110forwall & ceiling mount • Automatic sync or non -sync operation • Sync strobes and sync temporal horns, with horn silence on 2 wires in sync mode *Temporal or steadytone in non -sync mode • Internal volume control • Low current draw • Single gang and universal mount configurations • U` UL 464 & 1971 listed for both wall and ceiling mount- CSFM, ULC, FM and MEA approved •ADA/NFPA/ANSI compliant • Screw terminals accept 12 awg wire • Synchronization requires 5406 Sync Control Module or RSE-300 • Made in USA, ISO 9001 quality crafted Description Faraday's 2830 & 2831 Electronic Horns and 2834 Horn Strobes provide synchronous or non - synchronous operation. The 2830 mounts to a single gang box, the 2831 and 2834 have a universal mounting plate for 1 gang, 2 gang or 4" square box mounting. Faraday notification devices are designed with the installer in mind. They are constructed with the electronics in the housing and not in the box. This design eliminates possible ground faults from crowded electrical boxes. The Adapter feature offers fourfield selectable candela settings -15/75, 30/75, 75 or 110. An internal volume control provides adjustment of dBA output levels. See detail on page 2. The 283x devices automatically detect if the circuit they are connected to is synchronizing or non -synchronizing. N M 2 F Model 2830 Horn The 283xs may be connected to conventional NACs whose output is steady (non -pulsing) or to a NAC whose output is the Faraday sync protocol. The 283xs will automatically determine what kind of circuit it is connected to. When connected to a NAC with the Faraday protocol, the 283x devices will be synchronized and silenceable while the strobes remain flashing. In the non -synchronized mode the 2830 audible section can be field selectable to sound a continuous horn tone or a non -synchro- nized temporal horn pattern. Engineering Specifications The audible/visual notification appliances shall be Faraday Series 2834 Selectable Candela Strobe - Horns, or approved equal. The audible appliances shall be Faraday Series 2830 or 2831 Horns, or approved equal. The Series 2834, 2830 and 2831 Horns shall be UL listed under Standard 464 9614 Model ..� 2834 Horn Strobe The 283xs may be connected to conventional NACs whose output is steady (non -pulsing) or to a NAC whose output is the Faraday sync protocol. The 283xs will automatically determine what kind of circuit it is connected to. When connected to a NAC with the Faraday protocol, the 283x devices will be synchronized and silenceable while the strobes remain flashing. In the non -synchronized mode the 2830 audible section can be field selectable to sound a continuous horn tone or a non -synchro- nized temporal horn pattern. Engineering Specifications The audible/visual notification appliances shall be Faraday Series 2834 Selectable Candela Strobe - Horns, or approved equal. The audible appliances shall be Faraday Series 2830 or 2831 Horns, or approved equal. The Series 2834, 2830 and 2831 Horns shall be UL listed under Standard 464 9614 (Fire Protective Signaling). The visual segment of the Series 2834 shall be the Adapter Selectable Candela Strobe and shall be listed to UL1971 (Standard for Safety Signaling Devices for the Hearing Impaired). The appliances shall be listed for indoor applica- tions and shall be ADA/NFPA/ANSI compliant. The strobe segment of the Series 2834 shall produce a flash rate of one (1) flash per second over the Operating Voltage Range Limits. The strobe shall consist of a xenon flash tube enclosed in a rugged clear polycarbonate lens. The strobe shall be of a low current design, and shall provide a minimum of four (4) field selectable strobe intensity settings, 15/75, 30/75, 75, and 110 candela. All settings shall be UL1971 listed for both wall and ceiling mount applications. The selector switch shall be tamper resistant. It shall not be necessary to remove the appliance from the mounting surface to select the strobe intensity. In non -synchronous operation with steady power applied, the horn shall produce a temporal pattern or a steady horn tone..A two pin jumper shall be provided to select the temporal or steady tone pattern. In synchronous operation the Series 2834 Horn segment, and the Series 2830, and 2831 Horns shall produce a temporal pattern audible output, and Specifications Environmental 32°F to 120°F (0°C to 49°C) with 85% humidity Primary Input Voltage: Horn: 16-32 Vdc or VFWR Strobe: Operating voltage range limits 16-32 Vdc or VFWR Mounting 2830B, mounts to a 1 gang box 2831 B & 2834B, have a universal mounting plate for 1 gang, 2 gang or 4" square box L---. - . - shall have an internal volume control providing adjustment of dBA output levels. The appliances shall be designed for 24 VDC, 2 wire synchronous operation. The appliances shall be used on notifica- tion appliance circuits equipped with the compat- ible Faraday Series 5406 Sync Module, or other source of Faraday Sync Protocol and shall provide synchronization of both the strobe flash rate and the temporal audible output pattern. The strobe and audible signals shall not drift out of synchroniza- tion. The appliances shall also be designed so that the audible signal may be silenced while the strobes continue to operate, all on 2 wires. Inputs shall be compatible with standard reverse polarity circuit supervision by an FACP. The Series 2834 Horn -Strobe, and the Series 2831 Horn shall include a Universal Mounting Plate that shall allow mounting to single -gang, two -gang, and 4" square backboxes, as well as Faraday 3046 and 3047 Surface Boxes. The Series 2830 Horn shall be designed specifically for mounting to a single -gang backbox. NOTE: These notification appliances are UL listed and rated as "special application", which represents appliances which have been investigated to operate as described in the product's installation instructions over the voltage range of 16-32 VDC or VFWR. UL Horn Ratings at 10 Feet with 24 Vdc Supplied Temporal Horn — Maximum Vol.: 83.6 db @ 54 mA Minimum Vol.: 79.3 db @ 30 mA Steadytone — Maximum Vol.: 87.8 db @ 54 mA Minimum Vol.: 83.3 dB @ 30 mA Shipping Weight 2830: 8 oz. approx. 2831: 8 oz. approx. 2834: 12 oz. approx. 'CA Physical Dimensions I �2-3/4" l --1-314" 4-3/4"1 —1 -3/4" F112" � 4-112' 4-3/4"Ll O Model 2830 Model 2831 4-314"� 2 112" 1/2" 4-314"®' L J __J Selector Switch Model 2834 Typical Wiring Alarm Polarity shown from Contra Panel or previous device Notification Appliance ckt. 1,2 2830 Horn (Back box by others) 2 3 1 4 Max. Volume Detail - Volume adjustment (factory set at max. volume) 15 Detail - Adapter selector switch To next device or E.O.L. (Style WN - Class "B" ckts.) or -turn to F.A.C.P. (Style X/Z-Class "A" ckts.) Notification Appliance ckt 2834 Horn Strobe (Strobe & Horn on same circuits) 2834 Horn Strobe (Strobe & Horn on separate circuits) Alarm Polarity shown from Control Panel or previous device To next device or E.O.L. Cut jumpers to power audible signal and strobe from separate circuits iw To next device or E.O.L. (Style WN -Class "8" ckts.) or return to F A C P (Style X/ Notes: When audible signal and strobe are Strobe Notification Z -Class "A" ckts.) connected to same notification appliance Appliance ctk Audible Notification circuit, currentrating is combination of audible Appliance ckt. signal and strobe current. Ordering Information Accessories IIII i 3017B-0-14 Flush or surface box, 1-9/16" (D) red 500-694496FA 3017B-0-21 Flush or surface box, 1-9/16" (D) white 500-695775FA 3046B-0-14 Surface box, 2" (D) red 500-695340FA 3046B-0-21 Surface Box, 2" (D) white 500-695874FA 304713-0-14 Surface box, 2-3/4" (D) red 500-695341 FA 30476-0-21 Surface box, 2-3/4" (D) white 500-695875FA 3048B Flush box, 2-3/4" (D) 500-695342FA 5406B -0 -14 -24 -DC Sync control module red 500-696872FA 5406B -0 -21 -24 -DC Sync control module white 500-696873FA 15073 RSE-300 expander panel 599-699110FA IIII WARNING -The information contained in this document is intended only as a summary and is subject to change without notice. The devices described in this document have specific Siemens Building Technologies, Inc. instruction sheets which cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations Document, 8 Fernwood Road a Florham Park, NJ 07932 which also contains important information, are provided with the product and are available Tel: (973) 593-2600 • Fax: (973) 593 6670 from the Manufacturer. Information contained in these documents should be consulted Web: www.faradayfirealarms.com before specifying or using the product. For further information or assistance concerning Manufacturer. particular problems contact the 3/05 2.5M SBT/IG June 2004 - Supersedes sheet dated 12/03 AZ AFAA NAC Voltage Drop Calculator for Audio / Visual devices This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by, and the results do not exceed the limits set by the respective jurisdiction Point to Point Method End of Line Method Load Centering Method Project Name Rinehart.Retail, CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date -;-1/2/20061 Circuit Number N1.r' Totals Voltage Totals Voltage Totals Voltage Area Covered 'Space 1 Current FDistance Drop Current Distance Drop Current Distance Drop Nominal System Voltage 24 0.851 1 320 1.02 0.851 320 1.672 0.851 320 0.836 Minimum Device Voltage 16 End of Line Voltage 22.98 End of Line Volta e 22.33 End of Line Voltage 23.16 Total Circuit Current 0.851 Wire Ohm's Percent Drop 4.25% Percent Drop 6.97% Percent Drop 3.48% Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Distance from source to 1 st device 105 _ . 'r • 14 :. 3.07 Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance of circuit 14" 3.07 118=7.77 16=4.89 14=3.07 12=1.98 10=1.24 Enter current in amps. Distance 18-14 Awg = Solid Conductors 12-10 Aw = Stranded Conductors .150 = 150 ma from Voltage Notes: Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires (Positive and Negative) Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then Device 1Q 1'9.7_, 105 23.45 0.549 2.29% the manufactures listed minimum operating voltage (IE: rated operating voltage 20-32 VDC). Device 2 07 ° 40; 23.29 0.709 2:96% Device 3 0.1,a7 `. , 8Q 23.07 0.934 3.89% Device Manufacturer Farada ., ,. - ; :'ty Device Manufacturer Farada Device 4 ,0:197 : "an �:4'0 Device 5 0.063""-. '55' END 23.00 22.98 22.98 0.998 1.019 1.019 4.16% 4.25% 4.25% Current Horn Strobes @Rated Strobe.Onl _ Model # Candela Voltage Model # Candela Current @Rated Voltage END- ._;_.; 22.98 1.019 4.25% 2:83461'224 ': _. z�°: 75-.`; 0.197; 27.00b1224 �. 15 -0:063: END �_. __ _ _:; 22.98 1.019 4.25% .. _ ..�. '1,10 END `" 22.98 1.019 4.25% END 22.98 1.019 4.25% 283661424, ......:.. 75 END 22.98 1.019 4.25% ; END -- 22.98 1.019 4.25% END,. ' _... 22.98 1.019 0 4.25/° END 22.98 1.019 4.25% END 22.98 1.019 4.25% END . `.' 22.98 1.019 4.25% END 22.98 1.019 4.25% END -'J` 22,98 1.019 4.25% END a 22.98 .1.019 4.25% END 22.98 1.019 4.25% Totals 0.851 320 End of Line Voltage 22.98 MPC -6000 BATTERY CALCULATIONS PANEL ID: FACP Device Number Of Devices Stand-by Alarm Current (mA) Current Stand-by Total (mA) Alarm Total (mA MPC -6000 1 190 190 190 190 MPC-DACT 1 38 54 38 54 RDC -2 0 20 85 0 0 1.8 1.8 0 0 8704 - Single Input w. Relay Module 1.8 1.8 0 0 Total Current 228 244 I•lav(i-I1G\I 8700-S - Single Action Pull Station 9 1.8 1.8 16.2 16.2 8701 - Mini Monitor Module 9 1.8 1.8 16.2 16.2 8702 - Single Input Monitor Module 1.8 1.8 0 0 8703 - Dual Input Monitor Module 1.8 1.8 0 0 8704 - Single Input w. Relay Module 1.8 1.8 0 0 8705 - Conventional Zone Module 1.8 1.8 0 0 8710 - Photo Detector 1 1.8 1.8 1.8 1.8 8712 - Thermal Detector 1.8 1.8 0 0 8713 - FireSmart Detector 1.8 1.8 0 0 8715 - Audible Base 1.8 1.80 0 8716 - RelayBase 1.8 1.8 0 0 8717 - Duct Housingw/ relay1.8 1.8 0 0 8840 - Duct Housing1.8 1.8 0 0 8726-C - Remote Lam - Ceiling1.8 1.8 0 0 8726-W - Remote Lam - Wall 1.8 1.8 0 0 Device Current (mA) 34.2 34.2 Notification Circuits (See Attached for a list of devices on each circuit and load calculations. N1 1 0 0.851 0 N2 1 0 0.457 0 NAC CKT 3 1 0 0 0 NAC CKT 4 1 0 0 0 Total Notification Circuit Current - Must Not Exceed 8 Amps (Amps). 0.001308 0 Total Standby Current (Amps) Number of standby hours Total Stand-by AH Total Alarm Current (Amps) Alarm Hours Total Alarm Hours Total stand-by and Alarm AH Safety factor of 20% (5 minutes = .0833 hours) 6.32 7.58 Amp Hours