Loading...
HomeMy WebLinkAbout316 Rochelle Avep )� xniit {{ .b Address: -scription of Work: -Ba-1-0 istoric District _ Zoning: CITU' OF SANFORD PERNICC APPLICATION Date,: — Square Footage------- Value 0000tage__-- Value of Work: $ xmit "hype: Building I l;,xtrical _ Mechanical Plumbing Eire Sprinkler/Alarm Pool ectrical: New Service - N of AMI:'S N�t't Addition/Alteration Change of Service _ fcmporary Pole echanical: Residential Noir-Residential Replacement New - (Duct Layout & Energy Calc. Required) umbing/ New Commercial H of,Fixtures �A 11 of Water & Sewer Lincs N of Gas Lines umbing/New Residential: # of %tater ClosetsV�R Plumbing Repair – Residential or Commercial zcupancy Type: Residential �,I_ Commercial _ industrial _ instruction TypeWpt) (,_ 11 aif Stories: it of Dwelling Units: �� Flood Zone: __ (VEMA form required ) veers Name & Address: _IJ ittractor Name & Address: r ----------- Phone: —-------------. T� t2 ton_ S� 1✓_pM_-- -___ State License Number:_f�jyCS_/_/_•.�—_ �2 one & Far: goy utact Person:&�� y/�� _JU8 filling Company: —--------------------------- -- -- nrtgage Lender: _=---------- dress: chitect/Fngineer: Plrone. Fax ----- --- --- – plication is hereby made to obtain a pimnit to do the work and installations as indicated I certify that no wodc or instalfation has commenced prior to the aance of a pennit and ilia(all work wild be performed to meet standards of all laws regulating construction in this jurisdiction. I understand drat a separate j snit must be secured for EI..ECTRtcX.�L WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and ` Z CONMIJONEILS, etc. INER'S AFFIDAVIT: I certify that aft of the foregoing infomnation is accurate and (]tat all work will be done in compliance with all applicable laws regulating tsttuction and zoning. WARNING Tf•) OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING I LICE POR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND -1-0 OBTAIN FINANCING. CONSULT W ITH YOUR LENDER Olt AN TORNEY BEFORE RI CORDWO Y',OUR NOTICE OF COMMI NCLiMENT. L(Ce; In addition the requirentemvi oflltis pe nit, there may beadditionalrestrictions applicable to this property that may be found in the public records of county, and dyfe m y be aAtiggal j�ernlit�, quired kom other governmental entities such as water management districts, state agencies, or Iederal agencies. :eptanceof ff"itisver t otify the owner o the property of the reyui inerts o lorida Lien Law, 1 S 7 1 Sign e t A7; fit Date Signature of untractur/Age Date Print mer/Agent's Nam Print Contractor/Agent's Name \111111111111/q// 9 � S t e of Notary -State of orida \\\\ S frttat/// Sv e of Notary -State of Flo da Da c `��'Pa, �1S$IpHF . Difi��� �rrC i ��. �G�,......•9 �, 6�i est 13 ? r'ai 01041 Is / *_ #DD 418176 •ate Owner/Agent is ✓ Person illy KnowlM or ®'® ContractodAgent is Personally Known to Mc or OA .• J Produced ID#DD 418176 Produced 1D --_-__g •.�. a _, r,!v�� �i,_O/�n�•....N� r�F _\� 'ROVALS: TONING: cial Conditions: -0YMM ENG: _ _ BLDG: 1 14 113*> NOTES: 1. BALCONY RAILING k SC REEN NOT SHOUJN. 2. FOR GENERAL NOTES,EE SHEET 5-3. Structural plan review is limited to a general survey for code compliance. No review is implied nor was taken to verify structural adequacy RONALD D. DEVLEN, RE: (,TSL. AFG. NO. 49782 1 yl,# r-rb).' No. 06--143 DRAWN : MMD CHECK : RDD P rpt Code violations found during inspection are required to be corrected. Plan/permit issuance does not grant approval of a code violation. 2004 FBC109.1 IUATERF'ROOF MEMBRANE 8 FLASHING BY OTHERS CONCRETE TOPPIN (VARIES 2" TO 3") MATCH EXIST. CONDITIONS •5yp. NO.Z -3/4' F.T, 2 SHEW • • •THING ®FT 2x4 E� • ThAft d& • • _. • —JOI&T TO LEDGER BALCONY BEAM BEAM PER SK -12 5'-0�1 PROPOSED ALC®N'1' SECT f ®1I SCALE: 3/4" = V-0" SOFFIT $ RIM BOARL TO MATCH EXISTING 11-4, OVERHANG TO MATCH EXISTING ®EVLEN ENGINEERING, Inc. STRUCTURAL. ENGINEERING 3074 W. LAKE MARY BLVD. & PROJECT MANAGEMENT SUITE 132 LAKE MARY, FL 32746 PHONE: (407) 324-5300 REGATTA SFdORES APARTMENTE): BALCONY REPLACEMENT SANPORD, FLORIDA t DATE: 12/08/06 12/15/00 S-1 2 x 4 6 fro" O.C. 2x4 SILL PLATE O NEW 2x4 PLATE TO REPLACE Q ? DETERIORATED PLYWOOD FLOOR 14" TJI FLOOR JOIST m Q = 24" O.G. ~ W m T/LEDGER LOCATED TO MATCH EXISTING TO REPLACE (3) ROWS 3/8" x 4" LACE SCREWS DETERIORATED (HOT -DIP GALVANIZED) PLYWOOD: 14�p 24" O.G. NEW BLOCKING 2xro OR LARGER W/ #7 SCREWS x 2 1/4"GYP, PT 2x10 LEDGER 4" OC SIMPSON LTP4 e 32" O.C. TOP 8 BOTTOM NEW 1.-15"x14" LVL RIM LVL RIM TO PLATES BOARD (CONTINUOUS) DBL 2x4 TOP PLATE 2x4 's lro" O.G. ( DBL a let FLOOR BALLON"' SECT f ®N REPAI/FLOOR SHEATHING2 SCALE: 3/4" = 1'-0" PLANS REVIEWED TY OF RONALD D. DEVLEN, P.E. CIS AN F ORD FL. REG:.' 0.49782 Proj. No. 06-143 DEVLEN ENGINEERING., Inc, DATE: 12/08/06 STRUCTURAL ENGINEERING 3074 W. LAKE MARY BLVD. Z s ���0 DRAWN MMD & PROJECT MANAGEMENT SUITE 132 LAKE MARY, FL 32746 ZL PHONE: (407) 324-5300 CHECK RDD FAX: (407) 324-5999 EMAIL: RDEVLEN_PE@FARTHLINK.NET 2 01/04/07 REGATTA SHORES APARTMENTS: BALCONY REPLACEMENT SANFORD, FLORIDA I S-2 C;mNmR4Lm NOTES A. STRUCTURAL WORK SHALL BE IN ACCORDANCE WITH THE 2004 FLORIDA BUILDING CODE (FBC), AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS. B. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMEN510N5 AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE OWNER OF DISCREPANGIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFORE fPROCEEDING WITH THE WORK. C. THE CONTRACT STRUCTURAL DRAWINCz5 AND SPECIFICATIONS REPRESENT THE COMPLETE DESIGN OF THE STRUCTURE, THEY DO NOT INDICATE THE METHODS OF CONSTRUCTION UNLESS 50 STATED OR NOTED, THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE WORKMEN, OR OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO BRACING, SHORING FOR EARTH BANKS, FORMS, SCAFFOLDING, PLANKING, SAFETY NETS, SUPPORT AND BRACING FOR CRANES AND GIN POLES. D. PLANS, SECTIONS AND DETAILS ARE NOT TO BE SCALED FOR DETERMINATION OF QUANTITIES, LENGTHS, OR FIT OF MATERIALS. A. DESIGN DATA I. BALCONY LIVE LOAD .......... (0 P5F 2, DECK DEAD LOAD ....... 40 PSF (INCLUDES 3" LIGHTWEIGHT CONCRETE) 3. WIND (PER SECT. I(oOro) ... _ ...... 120 MPH (EXP. "B", IMP. FACTOR = 1.0, OPEN) (C$C TOP 2ro P5F, C4C SIDES 2a P5F) Woo= A. GENERAL a) ALL FASTENERS SHALL BE HOT -DIPPED GALVANIZED. b) 5OLT5 SHALL BE ASTM A301, HOT DIPPED GALVANIZED. STAINLESS STEEL BOLTS OF EQUAL DIAMETER MAY BE SUBSTITUTED. c) ALL FRAMING ANCHORS SHALL BE 6IMP5ON (G9O COATING) OR APPROVED EQUAL, INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. d) ALL WOOD MEMBERS SHALL BE PRE55URE TREATED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS AND DETAILS. �l CITYU WAN RONALD D. DEVLEN, P.E. FL. REG. NO. 49782 Prpj. No. 06-143 DEVLEN ENGINEERING,, Inc, DATE: 12/08/06 STRUCTURAL ENGINEERING 3074 W. LAKE MARY BLVD. 12 /15/x(0 DRAWN MMD & PROJECT MANAGEMENT SUITE 132 LAKE MARY, FL 32746 Z\ PHONE: (407) 324-5300 CHECK RDD FAX: (407) 3245999 EMAIL: RDEVLEN_PE@EARTHLINK.NET 2 01/04/07 REGATTA SHORES APARTMENTS: BALCONY REPLACEMENT BANFORD, FLORIDA I S-3 TUFFLEX W.P. COATING O4' CONC. DECK (TYP) �-- FORMED ALUM. CONC. SCREED 'CARSILE 860' PEEL 'N STICK MAT 2' ALUM. DRIP EDGE 1/2' TREATED CDX PLYWD. DECK EDGE OF BAL. DECK SECTION B SCALE: 6' = I'-0' SECTION A SCALE: 6'=1'-0' ::CO FIN. (TYP) 'OR BARRIER 0) 'EEL 'N STICK 'LEX W.P. COATING M. 4x2 'L' FLASHING 'EEL 'N STICK ;ONC. DECK (TYP) zSILE 860' PEEL TICK MAT REATED CDX 'WD. DECK L LINE 9 FLOOR JOIST o ::).C. R A I TA 51'40 S A I A TI I TS SANFORD, FLORIDA PROJECT: BALCONY REPLACEMENT DATE: 11/16/06 SECOND FLOOR SCALE: A5 NOTED COASTAL. RECONSTRUCTION,INC OFFICE(407)644-1800, FAX(407)644-0155 4950 HALL ROAD #B ORLANDO, FL. 32817 A R C H I T E C T S PAGE AA NO. 0003325 RIDA 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 Design FAX:407-774-4078 iso. W'A'N'.abdesigngroup.com OOOrGroup CA NO. 00009060 E N G I N E E R S J BLDG ° 57E 5NEET "I' DRAWN//_ w T' PAGE 006 [OF RIDA 6