Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1133 W Airport Blvd (4)
rr CITY OF SANFOIW PERNUT APPLICA"I'ION Permit # : Job :address: Description of Work: d -Aj"- 10(orm . �"( Historic District: Zoning: Value of Work: S ru Permit Type: Building Electrical Mechanical Plumbing hire Sprinkler/Alarm � Pool Electrical: New Service - # of AMPS Addition/Alteration Change of Service 'Temporary Pole""""' Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines _ Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Rdential Commercial _tz� Industrial Total Square footage: Conch uction Type: # of Stories: _/_____ # of Dwelling Units: .Flood .Gare: (FEMA form required for other than X Parcel # Owners Name & Addressers: _ Cont actor Nacre & Address: A117. /sox 0 a Phare &Fax:coil ttic t Person: Bonding Conrpany: Address: Mortgage Lender: Address: Architect/Engineer: Address: ttack Proof OfOwnership & Legal Description) ,j A' 1O,16 f tI TZi�a4e nJV)C I'll one: _j -,4074-6`3o - /_/ r8 : EXISTING Fire Alarm Control Panel Located in Karate School Closet Tel TClco Tel Sur r -J (Control Panel) (Day Care) (1) (Control Panel) (1) (Control Panel) - LB ©- © (u) (Day Care) - -- D - O (4) (Day Care) - Spare - Spare - Spare 120VAC Dedicated SCOPE OF WORK LEGEND [A(' Fire Alum Control Panel Pull Station at FACP Zone 2 Smoke Detector Over FACP Manual Pull Station Water Flow Switch Smoke Detector �-0 Water Flow Device by Others •-O Tamper R Backflow Devices by Oth L B tock Box Pull Stations in Day Care Horn Strobe Spare Zone Strobe Z Duct Detectors - NAC NAC Power Supply The Brio Business Center - Building #2 - complex has an existing 10 zone fire alarm panel that monitors the sprinkler system and provides power to sound horn strobes in each of the suites. This system was installed, and is monitored, by System Connections of Florida, Inc (EF0001150). The Bright Stars Day Care is being located into suites 1129 and 1133 of this building. A fire alarm system has been designed to comply with the Florida Fire Prevention Code, 2004 Edition, effective January 1, 2006, NFPA 101, 16.3.4.1 that includes the required smoke detectors and notification devices. These devices are to be connected to the existing fire alarm control panel and take up zone (5) for the smoke detectors and zone (6) for the manual pull stations. Notification devices in this area are connected to a separate NAC power supply that is located within the Bright Stars Day Care Center. FACP ZONE CHART Zone 1 Pull Station at FACP Zone 2 Smoke Detector Over FACP Zone 3 Water Flow Switch Zone 4 Sprinkler Tamper Switch Zone 5 Lock Box Zone 6 Smoke Detectors in Day Care Zone 7 Pull Stations in Day Care Zone 8 Spare Zone Zone 9 Spare Zone Zone 10 Spare Zone Backbox 4"x4"xt or 2"x4'xt 7/8" ** FOR INDOOR USE ONLY ** Plastic Grommet Note: Required for -Stub-Ups Only CEILING System Sensor Hom Strobe „ Part M: P1224MC Fire Alarm Device Strobe Lens dole tlIl" A.F.F to Strp�Lens of IL" Hnlfl>�Cnllin0 Whichever Is 1pwer FIRE ALARM DEVICE INSTALLATION DETAILS *** FOR HORN STROBE SYSTEMS ONLY *** NTS No Wall Penetrations by System Connections nl I I I I t _-- Brio B siness Center - Building 2 1105-1295 West Airport Blvd., Sanford` FL. 32773 F_ &Ih6 -I li�!lti�Q�l I I I I r I I Sunt Starr I Sunt StKit I Surra ]1 1169 1173 1177 1181 1185 1,5008E 11,3505fI I.5DDSIF 1.8005F 5' 76') (20'x75')1 (18c75)I (20'x75)1 (24'x75► I I I I 1t �' 1!-, FLOOR PLAN OF DAY CARE FACILITY SCALE: 1/8" = 1' Existing 1 Fire Alarm Control Panel For Complex I ILIBI, Existing Lock Box Device T e Number of Current Devlces Ams Total Current (Arl s Required Standby Time i(Typically 24 or 60 Hours F Alarm Loay Current Ams Main PC Board 1 X 0.065 - 0.(165 1.56 AH 1515 19.16 Power Su ervision Relays X 0.26 AH 18.68 2 SR Auxilia Current Draw X - 0 from TB4 Terminals 9 & 10 Multiplyby the Derating Factor X 1.2- .2*Total 17.62 TotalAmpere Hours Required= 3 AH 0.2120 STANDBY LOAD 18.92 Standby Lgad Current Ams Prepared By: System Connections of Florida Phone: 407-295-8!_52 Address: P.Q. Box 5858 City: Orlando State: FI Zip: 32858 Iievice # Required Standby Time i(Typically 24 or 60 Hours F Alarm Loay Current Ams 0.065 X 2i = Required At Time (Typically 5 or 10 Minutes 1.56 AH 1515 19.16 19.09 19.02 0.26 AH 18.68 2 SR 0.2020 Sub Total Standby/Alarm Am Hours 1.82 AH 18.80 Multiplyby the Derating Factor X 1.2- .2*Total 17.62 TotalAmpere Hours Required= 3 AH ` Derating Factor required to compensate for the non-linear discharge characteristic of a battery. Voltage Drop Analysis Notification Appliances FireLite FCPS-24FS6 4 FS8 Power Supply (3.0 -amp circuit) Source Voltaee: 19.25 VDC Low Line Protected Premises: Bright Stars Day Care / Brio Datta: 12/5/06 Address: 1129 West irport Dr City: Sanford State: F) I Zip: Note: Horn Strobes & Strobes (a) 110cd Prepared By: System Connections of Florida Phone: 407-295-8!_52 Address: P.Q. Box 5858 City: Orlando State: FI Zip: 32858 Iievice # PartNumber Current (..rtN'� Distance (Feet) Between Total Circuit Volts )rt (re) Each Device 10 AWG 12 AWCi-t .. AIVG 16 AWG 18 AWG I P2R 1 0.2120 1515 19.16 19.09 19.02 18.89 18.68 2 SR 0.2020 30 45 19.00 18.80 18.60 18.22 17.62 3 P2R 0.2120 15 60 18.92 18.66 i 8.40 17.91 17.13 4 P2R 0.2120 30 90 18.79 18.41 :8.04 17.35 16.23 5 P211 0.2120 50 140 18.58- 18.04 17.50 16.49 14.87 6 P2R 1 0.2120 15 155 18.52 17.94 17.35 16.26 14.51 7 SR 0.2020 20 175 18.45 17.82 17.18 15.99 14.07 8 P2R 02120 20 195 18.40 17.71 17.03 15.74 13.69 9 P2R 0.2120 35 230 18.31 17.55 16.80 15.39 13.12 l0 P2R 0.2120 20 250 18.27 17.48 16.69 15.22 12.85 11 P211 0.2120 10 260 18.25 17.45 16.65 15.15 a-2-; 3 12 P2R 0.2120 30 290 18.21 17.38 16.55 15.00 Ill 13 SR 0.2020 20 310 18.20 17.35 :x.51 14.93 1240 14 SR 0.2020 30 340 18,18 17.33 ;5.48 14.88 4-1-42 Total Current: 2.9280 % Voltage Drop: 5.54 9.97 14.40 Go 22.70 35.99 Go Go Go No Go -tt-tftl: ru ugif mulcales f value below the device's minimum voltage at indicated location and wire gauge. These calculations assulne a worst-case source voltage as measured by UL with the batteries depleted tri' 20.4 volts. Under AC power and for most of tPe drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it work down to 80% of i�s rated (published) minimum operating voltage. 12/5/2006 REVISED MAIN FACP BATTERY CALCULATIONS ARE INCLUDED IN SUBMITTAL PACKAGE DEC q 11$h 1 OFFICE ARMIT CCS tr, Gr) •P1* a QQ �« n t� 4 u7 --t tr, Gr) SHEET "I ITLE Fire Alarm 7 Addition to Main FRCP SHEET NUrvIPER FA 1.