Loading...
HomeMy WebLinkAbout140 Bristol Forest TrlCITY OF SANFORD PERMIT APPLICATION Permit # : I Date: -i - Job Address:, f•,7 I STP ,/- Description of Work: J 13 ry Jkj A-'5r-1?1FSxJ ROO -t +7 0 Eya5t"W Total Square Footage D Historic District: Zoning: Value of Work: $ Perrnit'1'ype: Building V Electrical" Mechanical )VA' Plumbing N4 Fire Sprinkler/Alarm /14- Pool Al 4 Electrical: New Service - it�off AMPS A14 Addition/Alteration k Change of Service /V4ITemporary Pole A,,4'� `7 Mechanical: Residential `y Non-llcsideutial Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: It of Fixtures 14 it of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: It of Water Closets A14 Plumbing Repair - Residential or Commercial Occupancy 'Type: Residential Commercial Industrial Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) Owners Name & Address: N?42 4 /�'1l 64,e��r- ; f/ dZ,-2-F Z- �17f /�Rlp_ .� .-�/-- L1 w �0.O_•D . � �i 7 '77 / Phone: � -1 (,83 � 1 3 O Contractor Name & Address: Phone & Fax: _ Bonding Company: Address: /N G. n y/ew. / ~ln 5 State License Number: �' �7 C � -�7 JTO CO r� to Contact Person: /L'./G/�vteJ ��� _Phone: #c>7 448 0 5� 2 Mortgage Lender: A1,9 Address: Arch,tect/Eng"I er; _/7, /3 dive Yhone: 7 1 :7� %J�J Address: ''` Ai=r-,/ 441 Uv 4>/ ,�/r.52• 5 Fax: 4Y5-7.IQ 23 3 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or instal lation has cotmnenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELEC'T'RICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, ctc. OWNER'S AFFIDAVTr: I certify that all of tire foregoing intbanatiou is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. 1F YOU INTEND TO OBTAIN FINANCING, CONSULTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: hi addition to the requirements of this permit, there may be additional restrictions applicable to this property that maybe firmrd in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of p rmit is verification that l n9fify the owner of the property of the requirements of F'lo a Lien Law FS 7`133 ����111� �� 4•� U ��, ��jj �L 1 � t� ent Signatur f Owner/Agent Date Signa are o of elpr/r� Ag `� • yr `\d` r tbe)l Narne Date DEBBIE BLANTON PAY COMMISSION # DD 113(A91 EXPIRES: February 25, 2007 Produced ID APPROVALS: ZONING: -eft 0. t V UTIL; Print 'pntraetor/Agent s Na )>• 'aFP 903 •`��a, `�� ..l7 b Signe of Notary -State of Fid' > lAn, atur Contractor/Agent isPersonally Known toe or I Produced 1D ` _41 F /t FD: ENG: BLDG: Special Conditions: Rev 03/2006w ,IOU. 5 �" � 2 STRUCTALL BUILDING SYSTEMS MASTER FILE: A I. DESIGN CODE &LOADS 0 I$ I E Structural plan review is limited to a general survey for code compliance. No review is implied nor. was taken to verify structural adequacy r F o ' O Lviolation. s round during inspection o be corrected.suance does not grant code violation. 2004 I, G 1. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 1997 UNIFORM BUILDING CODE (UBC),2003 INTERNATIONAL BUILDING CODE (IBC). 2003 INTERNATIONAL RESIDENTIAL CODE (IRC), AND THE 2004 FLORIDA BUILDING CODE - RESIDENTIAL (FBC), CHAPTER 3 AND ASCE 7-02, IN ACCORDANCE WITH SECTION R 301,2.1,1. 2. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS ARE INTENDED FOR RECREATIONAL/ OUTDOOR USE AND ARE CONSIDERED NON-HABITAL STRUCTURES WHICH ARE NOT HEATED AND/OR COOLED. 3. WHERE A COVER HAS AN ENCLOSURE BELOW, THE OPEN AREA OF THE LARGER WALL AND ONE ADDITIONAL_ WALL SHALL BE 66% OR MORE OF THE AREA BELOW 6'-8" MEASURED FROM THE GROUND. EACH WALL OPEN AREA SHALL BE EITHER INSECT SCREENING, READILY REMOVABLE. TRANSLUCENT/ TRANPARENT PLASTIC OR TEMPORED GLASS. NOT MORE THAN 0.125 -INCHES THICK, WHICH IS APPROVED BY THE UNIFORM BUILDING CODE. SEE ATTACHED STRUCTUAL BUILDING SYSTEMS PAGES: PAGE W31 TYPICAL GLASS ROOM WALL SECTION, PAGE WS2 FIGURE A 1 2" X 3" MODULAR ROOM FEMALE MULLION WI SCREEN SPLINE. FIGURE B 1 2" X 3" MODULAR ROOM MALE MULLION Wl SCREEN SPLINE. (Use as one part of two part upright and to frame top and bottom of opening) FIGURE E 3"THERMO MODULAR ROOM TOP CAP (use to frame lop of side wall modules when using 3" Thermo Modular Room Adustable Top Cap & Lower Assembly) FIGURE F 3" THERMO BASE CHANNEL (Use to receive panels on slab and to frame bottom of wall modules) FIGURE G 3" CORNER POST (Receives wall modules at all corners of structure) EXPLODED VIEW OF SNAP -A -ROOM MODULAR PATIO ROOM WALL SYSTEM PAGE WS3 EXPLODED VIEW OF COMPONETS PAGE S 1 ROOF PANEL SPAN CHART PANEL THICKNESS 3" X.024 GAUAGE, 110 M.P.H. WIND SPEED,1 FT OVERHANG. 20'1 MAX SPAN SNAP -N -LOCK COMPOSITE PANEL Foam - 1,0# Density E,P,S• Aluminum - 3105-H141H25 Alloy Steel -ASTM-AT201A526M-90 NOTE: THIS STRUCTURE SHALL BE CONSTRUCTED IN ACCORDANCE WITH Fasteners# 4,769,963 & 5,068,599 THE MANUFACTURER'S SPECIFICATIONS. 50,0011 I I I ,I I' I I I I I U m t�0 F— LU W I I I I I I INSTALLATION LOCATION I N SCREE ROOM W O EXISTING RESIDENCE CARLOS AND MARGARITA RAMIREZ 149 BRISTOL FOREST TRAIL SANFORD, FL 32771 PARCEL ID: 22-19.30-502-0000-0680 LEGAL DISCRIPTIOPN: LOT 68, PRESERVE AT LAKE MONROE , as recorded in Plate Bk 62, Pages 12 --16 Of the public records of SEMINOLE County, Florida On Eric Powell 5' 3" ROOF P NEL -- STRUCTUAL BUILDING SYSTEM Screen Room L__ -. 3 4 5 6 7 8 9 10 11 1. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 1997 UNIFORM BUILDING CODE (UBC),2003 INTERNATIONAL BUILDING CODE (IBC). 2003 INTERNATIONAL RESIDENTIAL CODE (IRC), AND THE 2004 FLORIDA BUILDING CODE - RESIDENTIAL (FBC), CHAPTER 3 AND ASCE 7-02, IN ACCORDANCE WITH SECTION R 301,2.1,1. 2. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS ARE INTENDED FOR RECREATIONAL/ OUTDOOR USE AND ARE CONSIDERED NON-HABITAL STRUCTURES WHICH ARE NOT HEATED AND/OR COOLED. 3. WHERE A COVER HAS AN ENCLOSURE BELOW, THE OPEN AREA OF THE LARGER WALL AND ONE ADDITIONAL_ WALL SHALL BE 66% OR MORE OF THE AREA BELOW 6'-8" MEASURED FROM THE GROUND. EACH WALL OPEN AREA SHALL BE EITHER INSECT SCREENING, READILY REMOVABLE. TRANSLUCENT/ TRANPARENT PLASTIC OR TEMPORED GLASS. NOT MORE THAN 0.125 -INCHES THICK, WHICH IS APPROVED BY THE UNIFORM BUILDING CODE. SEE ATTACHED STRUCTUAL BUILDING SYSTEMS PAGES: PAGE W31 TYPICAL GLASS ROOM WALL SECTION, PAGE WS2 FIGURE A 1 2" X 3" MODULAR ROOM FEMALE MULLION WI SCREEN SPLINE. FIGURE B 1 2" X 3" MODULAR ROOM MALE MULLION Wl SCREEN SPLINE. (Use as one part of two part upright and to frame top and bottom of opening) FIGURE E 3"THERMO MODULAR ROOM TOP CAP (use to frame lop of side wall modules when using 3" Thermo Modular Room Adustable Top Cap & Lower Assembly) FIGURE F 3" THERMO BASE CHANNEL (Use to receive panels on slab and to frame bottom of wall modules) FIGURE G 3" CORNER POST (Receives wall modules at all corners of structure) EXPLODED VIEW OF SNAP -A -ROOM MODULAR PATIO ROOM WALL SYSTEM PAGE WS3 EXPLODED VIEW OF COMPONETS PAGE S 1 ROOF PANEL SPAN CHART PANEL THICKNESS 3" X.024 GAUAGE, 110 M.P.H. WIND SPEED,1 FT OVERHANG. 20'1 MAX SPAN SNAP -N -LOCK COMPOSITE PANEL Foam - 1,0# Density E,P,S• Aluminum - 3105-H141H25 Alloy Steel -ASTM-AT201A526M-90 NOTE: THIS STRUCTURE SHALL BE CONSTRUCTED IN ACCORDANCE WITH Fasteners# 4,769,963 & 5,068,599 THE MANUFACTURER'S SPECIFICATIONS. 50,0011 I I I ,I I' I I I I I U m t�0 F— LU W I I I I I I INSTALLATION LOCATION I N SCREE ROOM W O EXISTING RESIDENCE CARLOS AND MARGARITA RAMIREZ 149 BRISTOL FOREST TRAIL SANFORD, FL 32771 PARCEL ID: 22-19.30-502-0000-0680 LEGAL DISCRIPTIOPN: LOT 68, PRESERVE AT LAKE MONROE , as recorded in Plate Bk 62, Pages 12 --16 Of the public records of SEMINOLE County, Florida 2 - #8 x 1"S.M•S TOP & BOTTO1 (TYP) I / #10 x 4" S.M.S W11/4" X 1112" NEOPRENE GASKET @ 8" O.C. 248 x 9116" S.M.S @ 8" O.C. EA SIDE OF WALL HEADER, (TYP) RING WALL IONS & OVER PANEL SKIN TOP EXPANDED POLYSTYRENE PANEL (3') DETAIL \ PANEL SKIN DETAIL -D ROOF PANEL CROSS SECTION ® JOINT #8 x 9/16" S.M.S or 1/8" POP 3" FILLER PANE RIVETS @ 8" O.C. MAX OR WINDOW (TYP) 3" FILLER PANEL OR WINDOW 3" THERMO CORNER P0'-_ Receives wall modules at all corners of structure / DETAIL -F EXI REIL 0-1 KI 0-1 CI J ID _--------_—! ! ----10 — " See Footing Ll— LEFT ELEVATION #10x4"S.M•SW/114"X1112" .060 X 3" HEADER EXTRUSION NEOPRENE GASKET @ 8" 0. FASTEN TO PANEL #8 x 9116" (TYP) TEK'S B TH SIDES @ 12" O.C. MAX TYP �t.t +++++ ++++++++ 3" LAMINATED ROOF PANE + + +t+ + + \SCIA W/ + UTTER " .055X3" RECEIVING CHANNEL EXTRUSIO - ..F FASTEN TO WALL PANEL WI #8 X 9/16" TEK'S 3" HEADER PANEL MI . ON BOTH SIDES @ 8' O.C. MAX FASTEN TO + ROOF PANEL WI #10 X 4" S.M.S.114" X 11/2" ` --055 X 3" RECE LNG CHANNEL EXTRUSION ALUM. NEO WASHER @ 8" O.C. MAX (TYP) I FASTEN TO LL PANEL WI #8 X 9116" TEK'S I ON BOTH S ES @ 8' O.C. MAX FASTEN TO I SCREEN NGS WI #10 X 4" S.M.S. 1/4" X 11/2" j ALUM. 0 WASHER @ 8" O.C. MAX (TYP) SCREENED OPENING AIL -B BEARING WALL CONNECTIONS & OVERHANG SCREENED OPENING .055 X 3" RECEIVING ANNEL EXTRUSION F .F : -\FASTEN TO WALL PAN W/ #8 X 9116" TEK'S .`'F .F ' ON BOTH SIDES @ 8' O.C. MAX FASTEN TO F F + SCREEN OPENING FLANG (TYP) t •F I F •F F + h 'F •I 3" KICK PANEL MIN. F •F .055 X 3" RECEIVING CHAN L EXTRUSION F'F }'F FASTEN TO WALL PANEL / #8 X 9116" TEK'S F + F FrN BOTH SIDES @ 8'0. , MAX FASTEN TO +FLAB W. 114" X 11/2" NC SCREW ANCHOR DE TA -A EQl IN" ,c, (TYP) 4" CO . LAB MIN. WALL CONNECTION FOUNDATION On Eric Powell 5' 3" ROOF P NEL 4 4ISETBA STRUCTUAL BUILDING SYSTEM Screen Room K SCALE: Vi .0 X 3" RECEIVING CHANNEL EXTRUSION FASTEN TO PANEL 3" Header Panel Min. WALL PANEL WI X 9116" TEK'S ON BOTH SIDES @ B-O.C. W/ #8 X 9116" TEK'S ON BOTH SIDES @ 8" MAX ATTACH TO C GC 037506 Y.4 •. ° 1 MAX FASTEN TO S EEN FLANGS WI #10 X 4" S.M.S.114" X 3" HANGING RAIL d, '.4. I - 1112" ALUM, NEO WA HER @ 8" O.C. MAX (TYP) ATTACH TO MASONRY HOST STRUCTURE WI 114" DIA. X 1112" WALL PANEL WI #8 X 9116" TEK'S ON 0TH SIDES @ F F F + 3" LAMINATED ROOF PANEL + } F ' CONCRETE SCREWS @ 24" U.C. MAX (TYP) MAX FASTEN TO ROOF PANEL WI # 0 X 4" S.M.S.114" X 1 I Lf�'4 1LU I .F CV U) I F F 11/2" WALL HEADER + #8 x 112" S.M.S @ 24" O.C, TOP $ creened opening' 4' 3' + +BOTTOM OF LEDGER.j -,-,i a'4 101011 UE 3 PANEL .F + + 44 III NG' I I Y• ° d.. •4• ° I EXISTING RESIDENCE I i I 12 OVE + + d• ,. 4 Y• (max � 5 3" G EXTRUSION S o .0 5 X 3 RE IN CHANNEL XTRUSI NFA TEN T .F •F + RECEIVING CHANNEL 2 - #8 x 1"S.M•S TOP & BOTTO1 (TYP) I / #10 x 4" S.M.S W11/4" X 1112" NEOPRENE GASKET @ 8" O.C. 248 x 9116" S.M.S @ 8" O.C. EA SIDE OF WALL HEADER, (TYP) RING WALL IONS & OVER PANEL SKIN TOP EXPANDED POLYSTYRENE PANEL (3') DETAIL \ PANEL SKIN DETAIL -D ROOF PANEL CROSS SECTION ® JOINT #8 x 9/16" S.M.S or 1/8" POP 3" FILLER PANE RIVETS @ 8" O.C. MAX OR WINDOW (TYP) 3" FILLER PANEL OR WINDOW 3" THERMO CORNER P0'-_ Receives wall modules at all corners of structure / DETAIL -F EXI REIL 0-1 KI 0-1 CI J ID _--------_—! ! ----10 — " See Footing Ll— LEFT ELEVATION #10x4"S.M•SW/114"X1112" .060 X 3" HEADER EXTRUSION NEOPRENE GASKET @ 8" 0. FASTEN TO PANEL #8 x 9116" (TYP) TEK'S B TH SIDES @ 12" O.C. MAX TYP �t.t +++++ ++++++++ 3" LAMINATED ROOF PANE + + +t+ + + \SCIA W/ + UTTER " .055X3" RECEIVING CHANNEL EXTRUSIO - ..F FASTEN TO WALL PANEL WI #8 X 9/16" TEK'S 3" HEADER PANEL MI . ON BOTH SIDES @ 8' O.C. MAX FASTEN TO + ROOF PANEL WI #10 X 4" S.M.S.114" X 11/2" ` --055 X 3" RECE LNG CHANNEL EXTRUSION ALUM. NEO WASHER @ 8" O.C. MAX (TYP) I FASTEN TO LL PANEL WI #8 X 9116" TEK'S I ON BOTH S ES @ 8' O.C. MAX FASTEN TO I SCREEN NGS WI #10 X 4" S.M.S. 1/4" X 11/2" j ALUM. 0 WASHER @ 8" O.C. MAX (TYP) SCREENED OPENING AIL -B BEARING WALL CONNECTIONS & OVERHANG SCREENED OPENING .055 X 3" RECEIVING ANNEL EXTRUSION F .F : -\FASTEN TO WALL PAN W/ #8 X 9116" TEK'S .`'F .F ' ON BOTH SIDES @ 8' O.C. MAX FASTEN TO F F + SCREEN OPENING FLANG (TYP) t •F I F •F F + h 'F •I 3" KICK PANEL MIN. F •F .055 X 3" RECEIVING CHAN L EXTRUSION F'F }'F FASTEN TO WALL PANEL / #8 X 9116" TEK'S F + F FrN BOTH SIDES @ 8'0. , MAX FASTEN TO +FLAB W. 114" X 11/2" NC SCREW ANCHOR DE TA -A EQl IN" ,c, (TYP) 4" CO . LAB MIN. WALL CONNECTION FOUNDATION 15 " 5' 7" 5' 6" . 5'-6" 5'-6" 5LT' 5] ---------oaten -- -_ , PLAT PLAN- On Eric Powell FRONT 3" ROOF P NEL 055 X 3" REC ING CHANNEL EXTRUSION FASTEN TO A STRUCTUAL BUILDING SYSTEM Screen Room A1.01 SCALE: Vi .0 X 3" RECEIVING CHANNEL EXTRUSION FASTEN TO PANEL 3" Header Panel Min. WALL PANEL WI X 9116" TEK'S ON BOTH SIDES @ B-O.C. W/ #8 X 9116" TEK'S ON BOTH SIDES @ 8" MAX ATTACH TO C GC 037506 MAX FASTEN TO S EEN FLANGS WI #10 X 4" S.M.S.114" X 3" HANGING RAIL HOST STRUCTURE WI #10 X 3" WD SCREWS @ 12" O.C. MAX. .055 X 3" RECEIVING CHANNEL EXTR SION FASTEN TO - 1112" ALUM, NEO WA HER @ 8" O.C. MAX (TYP) ATTACH TO MASONRY HOST STRUCTURE WI 114" DIA. X 1112" WALL PANEL WI #8 X 9116" TEK'S ON 0TH SIDES @ F F F + 3" LAMINATED ROOF PANEL + } F ' CONCRETE SCREWS @ 24" U.C. MAX (TYP) MAX FASTEN TO ROOF PANEL WI # 0 X 4" S.M.S.114" X 1 I DETAIL -13r .� + .� .F 112" ALUM. NEO WASHER @ 8" 0•C. AX (TYP) � F F 11/2" WALL HEADER + #8 x 112" S.M.S @ 24" O.C, TOP $ creened opening' 4' 3' + +BOTTOM OF LEDGER.j -,-,i 3 PANEL .F + + (TYP) III NG' ++ EXISTING RESIDENCE I i I 12 OVE + + (max � 5 3" G EXTRUSION S o .0 5 X 3 RE IN CHANNEL XTRUSI NFA TEN T .F •F + RECEIVING CHANNEL I WALL L WI#8 X 9116" TEK'S ON BOTH SIDES @ 8' O.C. IL -D +FASTEN x) «� TO SCREEN FLANGS Wl #10 X 4" S.M•S.1/4" X F + + j 1112" ALUM. NEO WASHER @ 8" O.C. MAX (TYP) 3 LAMINATED +++ screened opening,, _ + + + D L -C + ROOF PANEL I B )DT +F+ _..a:.., 15 " 5' 7" 5' 6" . 5'-6" 5'-6" 5LT' 5] ---------oaten -- -_ , PLAT PLAN- On Eric Powell FRONT ELEVATION THIS IS NOT A SURVEY STRUCTUAL BUILDING SYSTEM Screen Room A1.01 SCALE: Vi PREPARED BY: ERIC POWELL C GC 037506 EXISTING RESIDENCE cut back overhang - �I DETAIL- D Existin erh ng � I I I. 4' 3' I ERH 12" C III NG' I 12 OVE HANG (max ilk DET IL -D �;� (m x) «� II 3 LAMINATED _ ROOF PANEL iii )DT _..a:.., tr SIL -G I/Y I I 'll ill =3E = ==_-._ _- :._-T __ = = ==== ��==– -== = = __ --3�=--===_ II I _____- , 31' 50,0011 149 BRISTOL FOREST TRAIL SANFORD, FL 32771 2 J ROOF ELEVATION Screen Room Slab 1�I 7 8 ,055 X 3" RECEIVING CHANNEL EXTRUSION H STEN TO WALL PANEL \ EACH SIDI 48 0116" S.M.5 TEK'S OR 116" POP RNIET ( 8" O.C. MAX. ATTACH TO WD HOST STRUCTURE Wl910 X 3" WD SCREWS ®12' O.0 MAX. ATTACH TO MASONRY HOST STRUCTURE WI 114" X 1112' CONC. SCRE1 @ 24.0.0. MAX. (TYP) RECEIVING CHANNEL ILLERPANELI 'INDOW 3"-0,024 EXISTING CMU DETAI STRUCTURE RECEIVING CHANNEL CONNECTION Q EXIXTING STRUCTURE N.T.S. ,055 X 3" RECEIVING CHANN EXTRUSION FASTEN To WALL PANEL EACH SIDE WI2•rf8a9116"S.M.STE'IC OR 118"POP RIVET @8"O.C. MAK ATTACH TO WUHOSfS[RUCIURE WI410X3*W1 SCREWS@IZ'O.C.MAX ATTACHTO MASONRY HOST STRUCTURE W1114" 1 112" CCNC. SCREWS@ 24" O.C. MAX. (TYP) FILLERPANELIWI U W 3"4024 EXISTING STRUCTURE (4x4 SOLID WD POST) RECEIVING CHANNEL DFA1-E CONNECTION 9 - EXIXTING STRUCTURE N.T.S. 0o _ On Eric Powell Ck. EP APT. EP Wo 10126106 STRUCTUAL BUILDING SYSTEM Screen Room RIGHT ELEVATION '3"PM 60" SCREENING 60" S( '3" PANEL -3" PAN See FootinggeTL........... ESIDENCE NO ELECTRICALS ELEVATION: 99'-11" i 290 SgFt SUPE i i NEW SCREEN i ROOM I ('—'D1L-A --------------I A A 14 1.01 ®,J 1= 1 I ,I I I I I I I I FOUNDATION PLOOP, PLAN i X 3" RECEIVING CHANNEL EXTRUSION FASTEN TO WALL NEL W/ #8 X 9116" TEK'S ON BOTH SIDES @ 8' O.C. MAX FAS TO SCREEN OPENING FLANGS (TYP) —__ 3"KICK PANEL IN. C .055 X 3" RECEIVI CHANNEL EXTRUSION FASTEN TO WALL PANEL W/ #8 9116" TEK'S ON BOTH SIDES @ 8' O.C. MAX FASTEN TO S B W,1/4" X 1112" CON SCREW ANCHOR OR EQUAL 24" O.C. (TYP) D IL -A SEE FT DTL _ TION AA N.T.S. D NUFES SCOPE OF WORK: CUT BACK OVERHANG AND INSTALL STRUCTUAL BUILDING SYSTEMS COMPONENT SCREEN ROOM ON EXISTING PATIO FOOTPRINT. ATTACHED TO EXISTING STRUCTURE, NO ELECTRIC, NO AIR CONDITIONING" ALL ATTACHMENT PER MFG'S DETAIL SHEETS" NO MODIFICATION TO EXISTING STRUCTURE, STRUCTALL BUILDING SYSTEMS MASTER FILE: E D UILD TO EXI S TING GRADE SITE GRADING IS NOT INCLUDED IN THIS CONTRACT Any use or reuse by anyone without written verification fronlNOKM PORM CONMCMRS, INC, for the specifc purpose intended will be at their risk and such tiff or person shall solely bear full legal responsibility• NI documents within these pages or pag, shall remain the property of NORTH POINT& CONSTRUCTORS, INC., and may not be used by any person or firm for any other 7 Pj endeavor willlout wrihen consent of NOKfH POINTS CONSTRUCTORS, INC. J1� „ F H Rev. I Date Issuo History N.0�T'H P01N7'E C ru" N'L--)- T R U CTO J��, 1NCo C GC 037506 Oviedo Carlos & Margarita Ramirez 149 Bristol Forest Trail Sanford, Seminole Co., FL 33271-7996 On Eric Powell Ck. EP APT. EP Wo 10126106 INSTALLATION STRUCTUAL BUILDING SYSTEM Screen Room A1.01 10 FILE: FLRMS&W FILE: 114"=1'-0" LAsrPLUC 11/14/06