Loading...
HomeMy WebLinkAbout1165 W Airport Blvd (2)CITY OF SANFORD PERMIT APPLICATION RECEIVED NOV 14 2006 Permit #: Job Address: _U Description of V4 Historic District: Zoning: Permit Type: Building Electrical Electrical: New Service — # of AMPS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets_ Total Square Footage I , 500 Value of Work: $ Z , — r— D; J - Co Mechanical Plumbing Fire Sprinkle Alarm V/ Pool Addition/Alteration Change of Service Temporary Pole Replacement New (Duct Layout & Energy Cale. Required) of Water & Sewer Lines # of Gas Lines Plumbing Repair —Residential or Commercial Occupancy Type: Residential Commercial _,,/ Industrial Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) State License Number: eiaa `1 tlt0 (, 001 a p O 3 kleU i OlP rr,Qn Phone: i0`7. 2$ ) tr1i3 A 3CO T Bonding Company: N A Address: Mortgage Lender: iN IF1 Address: „ Architect/Eagineer: >U rl Phone: Address: Fa:: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other govemmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. I /-.>i Signature of Owner/Agent Date Signature of C ctor//Agent Date gnrl:x CA 11 '' Print Owner/Aeent's Name Print Contractor/Agen 's Name Signature of Notary -State of Florida Owner/Agent is _ Personally Known to Me or Produced J. APPROVALS: ZONING: ` t UTIILL: _ Special Conditions: Rev 03/2006 Date I XA sCeuA_ _ '' 131/4 Signatu of Not -State of Florida Date Ee7NNctery1Publjc-&-819o1FquelineSCourt Commission DD59Contractor/Agent is Person 5W Produced ID ka810,2&2010 FD: I ENG: BLDG: CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-2516 - FAX # 407-302-2526 DATE: 111 ir. I G BUSINESS NAME / PROJECT: ADDRESS: I I ke-%,'% E_,N PHONE NO.: FAX NO.: PERMIT #: CJ C`eV rJ CONST. INSP. [ I C / O INSP. j ] REINSPECTION [ ] . PLANS REVIEW [ F. A. [ ] F.S. { HOOD [) PAINT BOOTH j BURN PER T ] TENT PERMIT E TANK PERMIT [ I OTHER [f S r > TOTAL FEES: S (PER UNIT SEE BELOW) Address / Me. # / Unit # 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. 13. 14. 15. 16. 17. 18, 19. 20. Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. 1 _ 4 - Sanford Fire vention 15ivision Applicant's Signature r Bulletin 136 Rev.M R 117b1e Model F1 FR Model F1 FR Recessed Quick Response Sprinklers to Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional y Vertical Sidewall OHorizontalSidewall HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS&A No. 587-75-SA 6. Meets MIL-S-901C and MIL -STD 167-1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler V 1 2006 UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex - Upright Pendent Vertical Sidewall Conventional i Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type Standard -Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position K Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) SSU SSPUSMetric Y"' 15mn Standard Orifice with y," NET (R)' Thread 5.6 80 2.2 56mm 1,2,3,4,5,6,7 R3625 R3615 17 " 20mm Large Orifice with Y" NPT R3/a Thread 8.0 115 2.3" 58mm 1,2,3,4,7,8 R3622 R3612 17mm Small Orifice with Y" NPT R}7) Thread 4.2 60 2.2 56mm 1,2,8 R3623 R3613 10mm Small Orifice with " NPT WY Thread 2.8 40 2.2 56mm 1,2,8 R3621 R3611 10mm Orifice XLH with RY," Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional —Install in Upright or Pendent Position 4.2 5.6 8.0 60 80 115 56mm 56mm 58mm 4.6.7 4,7 R3674 R3675 R3672 10mm Orifice XLH with R/ Thread 15mm Standard Orifice with Y" NPT (RyThread ) 20mm Lange Orifice with 3/" PT R3/a Thread Upright Pendent Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Conventional Nominal Orifice Thread Size K Factor US Metric Sprinkler Height Approvaltll Organizations Sprinkler Identification Number ( SIN) y' 2 (15mm) y"NPT (R1/2) 5.6 80 2.2 (5smm) 1,2,3,4,5,7,8 R3615 1%"( 20mm) 41'NPT (R3/4) 8.0 115 231(58mm) 1,2,3,8 R3612 11mm) Y2" NPT(R1/2) 1 4.2 60 2.2" (56mm) 1,2,8 R3613 Y" ( lomm) y"NPT (R1/2) 2.8 40 22"(56mm) 1,2,8 R3611 lomm RYs 4.2 60 56mm 4.7 R3614 Refer to escutcheon data table for approvals and dimensions. 2 1/4- HOLE &A SZ2- 1 1 1S/16' OM 49. 2-1 C1' X 1/2" REDUCER TURN COLLAR UN77L TCHT AGWNST SPRINKLER WRENCH BOSS f II I* 00iyd 1 ADJUST 7 (r) lZ CEILINGICMJ. 2mm1 2 17/32- Da. 72, 2 mj rJ6Ff.01_F r) REFER TO F1 & F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 70 7'' 2. 2 518" DA. (66.7—j HOLE IN CEILING 2 5/16- DL4. (58. 7-1 CUP r a 1" X 112' REDUCER 4—__—______ I I L _ J CEILING 00 V8 FACE OF FITTING A __ _ TO FACE OF CEILING DIM IONL11 1J A r1, ADJV57M£ N/ IJEFG0. 9 1 I) REFER TO FP £SCU7CHEOA' DATA TABLE FOR APPROVALS AND DIMENSIONS. Model 171 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Inct.gnntinn nntn- Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size us Metric Height Organizations r Number (SIN) 1/2" 2" NPT (R'/2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm 2" NPT (R1/2) 5.6 80 2.2" (56mm) 4 tli LPC Approval is for Pendent position only. Orientation Deflector to Calling Dimension (Min. - Max.) Upright 4" - 12" 102mm - 305mm Pendent 6" - 12" 152mm - 305mm Vertical Sidewall US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Light Ordinary Identification Number (SIN) Orifice Size us Metric Length Hazard Hazard y" (15mm) NPT(R'/2) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. Horizontal Sidewall lJ6FGU4 7 FALL Of !q LING to ---- - WALL DIMLNSIUN 1 1/4" MIN. 31.Bmrn] 2 1/4" HOLE 014. Ir`rf'J 1/g. 4•-6• J Z2mm j 3.2mm1 1101.6mm- 152.4mmj CEILING TO I" X 112" RLUUCLR D£FLECIOR r1 j 1 15116-OIA.`). 1 172.2mmj TURN COLLAR UNTIL .1 TIGHT AGAINST SPRINKLER \\ WRFNCH RO.SS. 1 AWUSIMLNI 1) REFER TO ESCUTHC£ON DATA TABLE FOR APPROVALS AND DIMENSIONS. 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FIR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1 FIR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FIR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Tem rature Max. Ambient Temp. Bulb Color C F Ordinary 57 135 100-F(38'C) Orange Ordinary 68 155 100-F(38'C) Red Intermediate 79 175 150'F(660C) Yellow Intermediate 93 200 150-F(66C) Green High (t) 141 286 225'F(107'C) Blue Not available for recessed sprinklers. Escutcheon Data Escutcheon Face of Fining mom Approvals Adjustment irnension to Ceiling or Wall Dimension 1 Y„ F1 1,2,4,8 Max Recess 38.1 mm) 316"-1y 16" Min Recess X" 5mm-24rrm) 19.1mm) 1y„ F2 1,2,3,4,5,7,8 Max Recess 38.1 mm) 6'-1116" Min Recess 6" 5mm-17mm) 24mm FP 1.2 Max Recessed 1y" (38.1mm) 11 Push - 1316" Thread -off 1,2 Min Recessed 24mm No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non -operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "tai Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome 1) Other finishes and colors are available on special order. Consult the factory for details. 2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. 3) FP Push-on/Thread-off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reflabld The Reliable Automatic Sprinkler Co., Inc. 800)431-1588 Sales Offices 800)848-6051 Sales Fax 914)668-3470 Corporate Offices Nm.reliablesprinkler.com Internet Address Recyc Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 7N5 P/N9999970027 I Bulletin 110 Rev.S R 117b1 Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright - This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is normally used where the space above the piping is limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice —By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less water than the normal'h" (15mm) orifice sprinkler. Conventional —This deflector configuration is used primarily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra -high hazard installations. Model G Automatic Sprinklers Spray Upright, Spray Pendent d Conventional CI Upright Small Orifice Upright Pendent Conventional Application and Installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 W 0 MCD tz Technical Data K" Factor Sprinkler Identification Sprinkler Number (SIN) Sprinkler Type US Metric Height Approvals SSU SSP Standard -Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.62 81.0 2 /" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015y" (15 mm) Standard Orifice with y" NPT (R}2) Thread fi' (11 mm) Small Orifice with y" NPT (R}Z) Thread 4.24 61.0 2 Ya" (73 mm) 1, 3, 7 R1023 R1013 10 mm) Small Orifice with y" NPT (R}2) Thread 2.82 40.6 2Ye" (73 mm) 1, 2, 3, 7 R1021 R1011 8 mm) Small Orifice with y" NPT (R}Z) Thread 1.98 28.5 2 Ya" (73 mm) 1, 3, 7 R1022 R1012 z' (20 mm) Large Orifice with y" NPT (R}2) Thread 7.96 114.7 2'/e" (73 mm) 1, 2, 3, 7 R1026 R1016 I%2' (20 mm) Large Orifice with y4" NPT (RY4)Thread 8.20 118.2 2 %6" (75 mm) 1, 2, 3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4, 5, 6 R1027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional —Installed in Upright or Pendent Position 4.10 59.1 73 mm 5 R107410mmXLHwith10mmThread 15mm Standard Orifice with (R}2) Thread 5.62 81.0 73 mm 4, 5, 6 R1075 20mm XHH with (Ry,) Thread 8.20 118.2 75.4 mm 4.5 R1077 Temperature Ratings Maximum Sprinkler Ambient Rating Temperature Frame (1) OF C OF CClassification Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue 1) Frame color does not apply to painted or plated sprinklers Use sprinkler rating as identified on operating parts. Finishes() Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Bronze All Temperature Ratings ChrorT) All Temperature Ratings White All Temperature Ratings Only Frame and Deflector are Painted Special Application Finishes Bright Brass Plated Only frame, deflector and cap are plated. 135°F (571C), 165°F 74°C), 212°F (100°C) Temp. Rating. Black Plated Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated (2) Only frame and deflector are coated. Lead Plated 165°F (74°C), 212°F (100°C) and 286°F (141 °C) Temp. Ratings. Wax -Coated (3) 165OF (74°C) Clear Wax, 212°F (100°C) Brown Wax. Wax -Coated Over Lead Plated (3) 165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. 1) Other colors and finishes are available. Consult factory for details. 2) UL listed and NYC MEA Approved only. 3) 212°F (100°C) brown wax may be used on 286°F (141°C) sprinklers when maximum ambient temperatures do not exceed 150OF 66°C). UL Listed, FM Approved, NYC MEA 258-93-E. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee 6. VdS Schadenverhutung 7. N.Y.C. BS&A No. 587-5—SA or N.Y.C. MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector Upright Pendent Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Rellabld The Reliable Automatic Sprinkler Co., Inc. 800) 431-1588 Sales Offices 800) 848-6051 Sales Fax 914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address Revision lines indicate updated or new data. EG. Printed in USA 11M4 P/N 9999970005