Loading...
HomeMy WebLinkAbout2714 Ridgewood Ave (5)CITY OF SANFORD PERMIT APPLICATION Permit # : V`F Job Address: of Description of Work: Historic District: Permit Type: Building Electrical Mechanical Plumbing Fin Sprinkler/Alarm X_ Pool Electrical: New Service — # of AMPS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets _ Occupancy Type: Residential Commercial Construction Type: # of Stories: Owners Name & Address: Contractor Name & Address: 10(9 WilvWS/r / Rc ti Phone & Fa:: A07 Bonding Company: Address: Mortgage Leader. Address: Architect/Eogioar: Address: Addition/Alteration Change of Service Temporary Pole _ Replacement New (Duct Layout & Energy Calc. Required) of Water & Sewer Lines # of Gas Lines Plumbing Repair — Residential or Commercial _ Industrial of Dwelling Units: Flood Zone: (FEMA form required) Pbooe: Fax: RECEIVED 1 1 2006 639 Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commented prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand data separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, them may be additional restrictions applicable to this property that may be fowl in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agent' Acceptance of permit is verification that 1 will notifythe owner of the roq ' property of the utrements of Lion FS 713. Signature of Owner/Agent Date Signature of Contractor/Agent Date = Print Owner/Agent's Nance Contractor/Ag N V rtg i_e Signature of Notary -State of Florida Date Signature of Notary -State of Florida Owner/ Agent is _ Personally Known to Me or r/Agent ' Personally Known to Me or Produced m Produced ID K3=- 0-5 3t0) o '> APPROVALS: ZONING: UTIL: r FD: E'NG: BLDG. Special Conditions: Rev 03R006 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-2516 - FAX # 407-302-25//216 DATE: ) PERMIT #: V BUSINESS NAME / PROJECT: ADDRESS: an1(4 PHONE NO.: FAX NO.: CONST. INSP. [ j C / O INSP.:[ j REINSPECTION [ l . PLANS REVIEW [ j F. A. [ F.S. [ l HOOD [ j PAINT BOOTH.[ j BURN PERMIT [ j TENT(tRMIT E J TANK PER IT [ J OTHER.r a asterTOTALFEES: S (PER UNIT SEE BELOW) Address / Bldg. #f / Unit # Square Footaee Fees ver Bldp.. / Unit 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. _ 13, 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. It _ Sanford Fire Prevention Divis' Applicant's Signature 0 Fire Alarm Submittal Package FOR ROSELEA APARTMENTS 2714 RIDGEWOOD AVE. SANFORD, FL U N ITS 49, 50, 51, 52 Advanced Compatible Solutions, Inc. d.b.a. ACS FIRE & SECURITY 10151 University Blvd. #179 Orlando, FL 32817 EF- 20000383 Contact: Martin Rudzik 407-929-3839 SEp 6 July 14, 2004 DF-52004 F-050 Fire•LITe®ALarms BG-12 Series Manual Fire Alarm Pull Stations www. fire lite. coin Section: Conventional Initiating Devices GENERAL The Fire-Lite Alarms BG-12 Series is a cost-effective, fea- ture -packed, non -coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end -user in mind. The BG-12 Series features a variety of models including single- and dual - action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull -force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual -action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non -English-speaking persons. Braille text included in finger -hold area of operation handle and across top of handle. Multiple hex- and key -lock models available. U.S. patent -pending hex -lock needs only a quarter -turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long -life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located in- side). Four -position terminal strip molded into backplate. Terminal strip includes Phillips combination -head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed -out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). California State Fi u + Marshale C F> L US 7150-0075:184 LISTED FM M EA 67-02-E APPROVED u Terminal numbers are molded into the backplate, elimi- nating the need for labels. Switch contacts are normally open. Can be surface (with SB-1/0 or SB-10) or semi -flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single -gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the Fire-Lite Legacy BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point -of -Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep I O 9001ourproductinformationup-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENINEFRINR 81NANUFACTURINRFormoreinformation, contact Fire-Lite Alarms, One Fire -Cite Place, Northford, QUALITY SYSTEMSConnecticut06472. Phone: (800) 627-3473, Toll -Free FAX: (877) 699-4105. DF-52004 • 07/14/04 — Page 1 of 2 CONSTRUCTION Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlertTm horn/strobe series. OPERATION The BG-12 manual pull stations provide a textured finger - hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non -English-speaking persons. Pushing in and then pulling down on the handle activates the normally -open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent), twist one quar- ter -turn, then open the station's front cover, causing the spring -loaded operation handle to return to its original position. The alarm switch can then be reset to its normal non -alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: OOMOMIM0 00-00 D010 0 0-10 000 MOB 55MOOOO 6c)IOIIlID S®0 6.0UM0 42s®O 03.97m) 11423OD) 03.970u) 152400) 00.79m) 4.121 MO 4222 ®0 4.121 ®0 4.69 M0000 42s OIIIID 0 ME 10.4/00) 10:1200) 1OA/00) 119100) 00./900) 0 ME 1.39 M0000 1.439 M11100 1.375 =0 2.0 OIII10 3S3m) 3.66111) 3.49m) S.08m) 4.445m) 5200411 N Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A (P 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non -code, with a key - or hex -operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall ap- pear on the front of the stations in white letters, 1.00 inches 25.4 mm) or larger.' Stations shall be suitable for sur- face mounting on matching backbox SB-10; or semi -flush mounting on a standard single -gang, double -gang, or 4" 10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- Page 2 of 2 — DF-52004 • 07/14/04 ties Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. NOTE: The words "FIRE/FUEGO"on the BG-12LSP shall ap- pear on the front of the station in white letters, approximately 31 4"high. PRODUCT LINE INFORMATION Model Description BG-12S Single-action pull station with pigtail connec- tions, hex lock. BG-12SL Same as BG-12S with key lock. BG-12 Dual -action pull station with SPST N/O switch, screw terminal connections, hex lock. BG-12L Same as BG-12 with key lock. BG-12LSP Same as BG-12L with English/Spanish FIRE/FUEGO) labeling. BG-12LOB Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and seal- ing gasket. BG-12LO Same as BG-12L with "outdoor use" listing. Does not include backbox. BG-12LA Same as BG-12L with auxiliary contacts. BG-12LPS Same as BG-12L with presignal feature. BG-12LPSP Same as BG-12LPS with English/Spanish FIRE/FUEGO) labeling. SB-UO Indoor/outdoor backbox. SB-10 Indoor use backbox. WP-10 Outdoor use backbox. WBB Outdoor use backbox. 17003 Key lock. 17007 Hex lock. 1.390" 35.306) Wire Length Strip Gauge 1.000" 25.40) 0.750" 19.05) 5.500" 139.70) mm) Es E Mini -Alert Sounders Red Beige White PA400 PA400 PA40OW PA40OR-F PA40OB-F PA40OW-F - 7t% PA 40O W Product Overview 12 and 24V operation System Sensor's Mini -Alert sounders and sounder/strobes are suited to provide 1.5 cd add -on strobe available primary and secondary signaling for fire and security applications. System Sensor's PA400 Series Mini -Alert sounders operate at 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The PA400 sounders are available with or with- out FIRE identification and are offered in red, beige, and white. Engineering Specifications Mini -Alert Sounders shall be a System Sensor Model capable of operating at FM aPA 24VDC. Sounder shall be listed to Underwriter's Laboratories Standard UL464 LISTED W4A5.A az7-9196E-EC5548OW4AS.AV 33for fire protective signaling systems. Sounder shall have an operating tempera- 54011 7125- 1209:169 ture between 14°F and 140'E Mini - Alert Sounder Specifications Dimensions 41/ 2" x .23/4"X 11/8" Mounting Surface Single gang back box Flush 4" x 4" BBD deep back box (23/4"deep) Weight 2. 4 oz.(159 g) Input Terminals Operating Voltage 12 to 18 AWG 24VDC FWR unfiltered* Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC. Ordering Information/Current Draw Operating Temperature Range 14o to 140*F (-10* to 60*C) Red Beige White Descri tion Voltage Max. Operating ICurrent@12VMax. Operating Current @ 24V 1d13 Output UL ** PA40OR PA4008 IPA40OW Mini -Alert sounder 12/24VDC 120.8 mA 147.4 mA 82 PA40OR- F PA40OB-F I PA40OW-F Mini -Alert sounder ("FIRE" identification) 12/24VDC 120.8 mA 147.4 mA 182 Sound output varies depending upon voltage and sound selected. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor - Far East System Sensor - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.637,1770 x.2700 St. Charles, IL 60174 Fx: 905.812,0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph:65.6273.2230 Ph:613.54.281.142 Ph:70.95.937.7982 www. systemsensor.com Fx: 44.1403.891921 Fx:65.6273.2610 Fx:613.54.281.172 Fx:70.95.937.7983 02004 System Sensor. The company reserves the right to Change product specifications without notice. A05-0346-001.5/04.#1213