Loading...
HomeMy WebLinkAbout474 Kays Landing Drt Per.332(9Permit # . ob LA14JobAddress: Description of Work: Historic District: CITY OF SANFORD PERMIT APPLICATION r- Zoning: Value of Work: Date: a-[-Ok 61M Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool v Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gras Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential _Z_ Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: j ( FEMA form required for other than X) Parcel N: 3 -1 ' ^ 3C t J - I ( Attach Proof of Ownership & Legal Descriptiatr) Owners Name & Address: Engj-e HGM-es Contractor Name & Address: Phone & Fax: Bonding Company: Address: Mortgage Lender: Address: Arcbitect/Engineer: Address: 01"1 -34'60 Phone: 40-7- r+r\ 1 n A State License N.. umber: CC Contact Person: rVCi Phone: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate PermitmustbesecuredforELECTRICALWORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIRCONDITIONERS, etc. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable. In c• i,•r tl ring constructionandzoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN Y(Jt il':, r y n TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER GCl i,. l ATTORNEYBEFORERECORDINGYOURNOTICEOFCOMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the pnhlir: r,coj(L of thiscounty, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is ri that 'II notify the owner the prop of the requirements of Florida Lien Law, F 713. Signature of Owner/Agent Date , a re of Contractor/A ent arc Nei T -In t mo,- 1 U r 7caner/ Agent's Name Print Kc r n s am n MAUt)V 11111 ICU SignatureofNoary-State of Florida Date nature of Notary -State of Florida Date RONALD C. HOMAN NOTARY PUSUC - STATE OF FLOMM COMMISSION # DD22053 Owner/ Personally Known to Me or EXPIRES 9/6=7 Contractor/Agent is ILSOMWOTs_Personal REBECCA BRITTAIN I u t'bNOTARY1 _ Produced ID 1 Notary Public - State of Florida My Commission Expires Jun 7, 2009 5 q p = Commission # DD 438415 APPLICATIONAPPROVEDBY: Bldg: Zonin G N !1 cc '%:}'osr - gUrilitics: nr , aendaiayNationatNotary Assn. Initial & Date) (Initial & Date) (Initial Special Conditions: art , r- ... r rn , . I ,ram CITA' OF SANFORD PERMIT APPLICATION Permlt # : "' 37 Date: Job Address: Description of Work: RAS, IA)1 (4 Total Square Footage Historic District: Zoning: Value of Work: S ISO, W Permit Type: Building Electrical L-*"'Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service - # of AMPS Additior Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct layout & Energy Calc. Required) Plumbing/ New Commercial: N of Fixtures H of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: k of Water Closets Plumbing Repair - Residential or Commercial Occupancy Type: Residential Commercial Industrial Construction Type: q of Stories: H of Dwelling Units: Flood Zone: (FEMA form required Phone & Fax: Beading Company: Address: Mortgage Leader. . OIL-f-Fg4iJ (\ FC. 3?Z04 State License Number: e-00 ! 1 Y. q Contact Person: Phone: Address: Architect/Engiacer: R it-.flN ' Phoac: Address: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable t this property that may be found in the public records of this county, and there may be additional permits required Dorn other governmental entities such as war anagcment districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements f ri lien LaV9 711 Signature of Owner/Agent Date Signature of Contractor/Ark Date Print Owner/Agent's Name Print Contractor/Agent's Name Signature of Notary -State of Florida Owner/Agent is _ Personally Known to Me or Produced ID APPROVALS: ZONING: UTIL: Special Conditions: Rev 03/2006 Date Signature of Notary -State of Florida Date FD: Contractor/Agent is _ Personally Known to Me or Produced ID ENG: BLDG: of Central Florida, Inc. LIMITED POWER OF ATTORNEY 1123 Seminola Boulevard Casselberry, FL 32707 Office: (407) 696-2300 Fax: (407) 696-2360 I hereby name and appoint tom— „c.,` to by my lawful attorney infacttoactformeandapplyto ? sTE for a permit for work to be performed at: and to sign my name and do all things necessary to this appointment. STATE OF FLORIDA COUNTY OF SEMINOLE nt was acknowledged before me this 1 day of 20- by James M. Burke, who is personally known to me. Public, State of Florida REBECCA BRITTAIN Notary Public - State of Fbrida My Commission Expires Jun 7, 2009 Commission 9 DD 438415 Bonded By National Notary Assn. P - !'.. BE SURE.. . Check with ^ the POOL PROS POWER OF ATTORNEY ELECTRICAL PERMITS STATE OF FLORIDA COUNTY OF ORANGE KNOWN to all men present, "Robert M. James", of Bob James Electric does hereby nominate, constitute and appoint bt_ 2. _—- ,-as his attorney in fact for procuring Electrical Permits at: L4 ,_q q LC,,^is l,A-n-O t rota 09- Job Address) i Before me, the undersigned authority, personally appeared, Robert M. James, who is personally known to me. REBECCA BRITTAIN Notary Public - State of Florida My Commission Expires Jun 7. 2W9 Commission p DD 438415 Bonded By National Notary Assn. 11% 70a, 11, "t . rNo,. Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 z, D"10 JOHNSON. CFA, ASA PROPERTY s v APPRAISER SEMINOLE COUNTY FL. 1 1 Ol E. FIRST ST SANFORD, FL 32771-1468 407- 665-7506 2006 WORKING VALUE SUMMARY GENERAL Value Method: Market Parcel Id: 34-19-30-520-0000-1410 Number of Buildings: 0 Owner: LO LAND ASSETS LP Depreciated Bldg Value: $0 Own/ Addr: LTO LLC KAYS SPRINGS Depreciated EXFT Value: $0 Mailing Address: 220 MAIN ST STE 1150 Land Value (Market): $62,000 City, State,ZipCode: IRVING CA 92614 Land Value Ag: $0 Property Address: 474 KAYS LANDING DR SANFORD 32771 Just/Market Value: $62,000 Subdivision Name: KAYS LANDING PHASE 2 Assessed Value (SOH): $62,000 Tax District: S1-SANFORD Exempt Value: $0 Exemptions: Taxable Value: $62,000 Dor: 00-VACANT RESIDENTIAL Tax Estimator 2006 Notice of Proposed Property Tax 2005 VALUE SUMMARY SALES 2005 Tax Bill Amount: Deed Date Book Page Amount Vac/Imp Qualified 2005 Taxable Value: Find Comparable Sales within this Subdivision DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS LAND LEGAL DESCRIPTION Land Assess Land Unit Land FrontageDepthPLATS: Pick... Method Units Price Value LOT 141 KAYS LANDING PHASE 2 PB 69 LOT 0 0 1.000 62,000.00 $62,000 PGS 44 - 44 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http:// www.scpafl.org/pls/web/re_web.seminole_county_title?parcel=3419305200000l 410&cpad=KAYS... 9/11 /2006 Cr iniinuaaauaannnininada.nniaiea nnilnH Prepared By b VAA C Florida Pools of Central Florida, Inc. 1123 Seminola Blvd. Casselberry, Florida 32707 NOTICE OF COMMENCEMENT State: Florida County: THE UNDERSIGNED hearby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statues, the following information is provided in this Notice of Commencement. 1 Description of property: (legal description of property, and j, A 5 k. nF, [\f . :::;.. MILMa MARYANNF MORSE, CLERK t)F CIRCUIT LOURT WAINIIt-I: 1;(AJNTY 8K %405 Vq 10741 flpq) CLERK'S # 2006146709 WWROED 09/12/2006 0003:44 pM WCORDINO FEES 10.00 W1,1IN0I_D 8Y L McKinley if CERTIFIED COPY{ ' MARYANNE MORSE CLERK OF CIRCUIT COURT SEMINOL COUNTY. FLORIDA 6Y D U L K SEP 12 2006: ON 2 general Description of Improvements: v Install In -ground swimming pool3OwnerInformation: A. Name and Address hth{HmS B. Interest in Property e, 51 rt, P c ti; C. Name and address of fee simple titleholder (if other than owner) SAME 4 Contractor: (name and addressV 5 Surely: A. Name and Address: B. Amount of Bond: 6 Lender: (name and address) Florida Pools 1123 Seminola Blvd Casselberry, Florida 32707 N/A N/A Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7, Florida Statues name and address) N/A 8 In addition to himself, Owner designates the following person(s) to receive a copyoftheLienor's Notice as provided in Section 713(1)(b), Florida Statues (name and address) ABOVE NAMES CONTRACTOR9ExpirationdateofNoticeofCommencement (the expiration date is 1 year for thedateofrecordingunlessdifferentdatespecified) Signature of Owner M•9S, Y Driver's License NumberNEtL Owner's Name Owner's Address 5 r r All information must be printed legibly to comply with recording requirements STATE OF FLORIDA COUNTY OF_5 Et--kj tj t) Lt The foregoing instrument was acknowledged before me this Flo U (o by jJ j L K& who is personall o haproduced s as identification and who did (did n take and oa Signature of person taking acknowledgement) Name of officer taking acknowledgement- typed or stamped RONALD C. HO ( Title or RanK) NOTARY PUBLIC • STATE OF FLORIDACOMMISSION # DD228953 EXPIRES 91612007 BONDEDTHRU I-BWNOTARYI F"h*q334P'1123 Seminola Bgulevrra of Central Florida, Inc. Casselberry, Florida 32707 Main Office: (407) 696-2300 FLORIDA POOLS CONSTRUCTION AGREEMENT (Part 1 of 4) FLORIDA POOLS OF CENTRAL FLORIDA, INC., "FLORIDA POOLS," State certified contractor, CPC048214, a Florida corporation whose Corporate Offices are located at 1123 Seminola Blvd., Casselberry, FL 32707, hereby agrees to construct for and sell to Home Phone Office Phone collectively called the "work") to be installed at uyer"), whose residence is/or place of business Florida (Zip) the swimming pool and related equipment described below (herein City . Zip -- Legal L..ar < 4- ( for the cash price of $ O , . V and Buyer hereby agrees to purchase the work r said cash price to be nad'd as follows: Down Payment ($ — ); Balance 40% ) ( g l t , tJatexcavation; /o ($ ) at gunite; 18% ($ ) at decks, prior to final top finish surface; an /o ($ 5 4-rl 0 ) at startup of pool/spa equipment; prior to utilization. Florida Pools shall carry out the work on the terms and conditions set forth on the reverse side hereof. If Buyer has not allowed construction to commence within sixty (60) days from date of this agreement, Florida Pools reserves the right to renegotiate the contract price. BUYER'S RIGHT TO CANCEL You may cancel this Agreement by providing written notice to Florida Pools, 1123 Seminola Blvd., Casselberry, FL 32707, in person, by telegraph, or by mail. This notice must indicate that you do not want the goods or -services and must be sent by certified mail postmarked before midnight of the third (31') business day after signing this Agreement. If you cancel this Agreement, the Seller may not keep all or part of any cash downpaymenl. Any property traded in, any payments made by you under the Agreement and any negotiable instrument executed by you will be returned within ten (10) business days following receipt by the Seller of your cancellation notice, and any security interest arising out of the transaction will be cancelled. If you cancel, you must make available to the Seller at your residence, in substantially as good condition as when received, any goods delivered to you under this contract; or you may, if you wish, comply with the instructions of the Seller regarding the return shipment of the goods at the Seller's I expense and risk. If you do make the goods available to the Seller and the Seller does not pick them up within twenty (20) days of the date of your notice of cancellation, you may return or dispose of the goods without any further obligation. If you fail to make the goods available to the Seller, or if you agree to return the goods to the Seller and fail to do so, then you remain liable for perforniancc of all obligations under this Agreement. Date) 1 HEREBY CANCEL THIS TRANSACTION. Date) ARBITRATION Buyer's Signature) Florida Pools and Buyer hereby elect binding arbitration as their exclusive method of settling all controversies and claims existing between them relating to this Agreement without regard to whether such claims or controversies arise under contract, tort, statute, regulation, ordinance, or other law. Arbitration proceedings shall be conducted in accordance with the Rules for Swimming Pool Arbitration adopted by the Bludsworth Central Florida Chapter of the National Spa and Pool Institute (NSPI) Arbitration Committee and said Rules are hereby incorporated by reference into the terms of this Agreement. Additional information may be obtained by writing the chairman of the Bludsworth Central Florida Chapter at the address referenced in the RULES FOR SWIMMING POOL ARBITRATION. Arbitration proceedings under this Agreement shall be commenced by either party by sending a written request for arbitration to the Chairman of the Central Florida Chapter of NSPI Arbitration Committee, together with any filing fees required. Requests for arbitration shall be submitted on "Request for Arbitration" forms that can be obtained from the local NSPI and must set forth the issues in dispute, and or the amount claimed as damaged, and the relief sought. Notwithstanding the foregoing, Buyer and Florida Pools agree that Florida Pools retains the right to file a claim of lien against the property and to protect this lien until ultimate resolution of the dispute. Buyer acknowledges that he has read and received a complete, legible copy of this Construction Agreement (Part 1), including the items and conditions contained on the reverse side hereof, and a complete, legible copy of each other document which Florida Pools has required or requested Buyer to sign. Buyer acknowledges receipt of the Swimming Pool Specifications and the Exclusive Service Agreement (designated as Parts 2 and 4 of this Construction Agreement). Buyer shall receive a copy of the Plans (designated as Part 3 of the Construction Agreement) as soon as they are completed. l Dated this ( - re day of KS, , 2006. Buyer's Signature Buy e ' ature Sales Representative FLORIDA POOLS This Agreement is not valid until accepted by an officer of the Seller. Accepted this date By Title . Rcvkion Dow 6120/00 CCL IBI ENGL CCL/IBI CONSU TBAINTS, INC. AUTHORIZATION ' ENGINEERS SURVEYORS PLANNERS 2200 PARK CENTRAL BLVD. N. SUITE 100 POMPANO BEACH, FL 33064 (954) 974-220D POMPANO BEACH ORLANDO TAMPA JUPITER WWW.CCL-POMPANO.COM WWW.CCL-ORZANt7O.COM EKA Y' S LANDINC PHASE 2 \ NA17ONAL FLOOD INSURANCE PROGRAM COMMUNITY NUMBER 120294 PANEL NUMBER 12117C0040f MAP REVISION 03/17/1993 FLOOD ZONE x BEARING BASED ON THE WEST LINE OF THE NOIRIHEAST 114 OF SECTION J4, TOWNSHIP 19 SOUTH, RANGE 30 EAST. SEMINOLE COUNTY, FLORIDA, BEING S 0074*40' E. AN ASSUMED MERIDIAN. L 9 G 9 N D: R- RADIUS 0 L- ARC DISTANCE a- CENTRAL ANGLE pfA/C - MR CONEED17IONER SLAB N LM.E. ENTERLIND LAKE GMAINTENANCE EASEMENT NT P U.E. UTILITY EASEMENT PF.. FINISH FLOOR CFHYD. FIRE HYDRANT W.M. : WATER METER ElW.V. WATER VALVE P uLLNSEV UV51NESS I = SET NAIL AND DISC L.B. 5610 a-PPOINTOOFCCOMPOUND CURVATURI POINTDOFI REVERSEICURVATUREV. CABLE TV LIGHT POLE C. ELECTRIC SERVICE POINT OF TANGENCY PROPOSED ELEVATION SCALB: V a 40' CCL . IBI A OIWMN or 1NC 1,w QPO//P LOCATION SKETCH NOT TO SCALE) 141 KAYS LANDING DRIVE YUr.7 , ( 50' R/GHT-OF-WAY) CITY OF SANFORD 4 bye I VX T612& zs as0 F I te aoawr 1Z00' AREATABULATIONT ON _ _ OO Clb mic OT arf0;030tSO.FT, c 1— nt g VAS• In IMPERWOUS - 99JtSO. FT. 1 V ,p I 00• = 61.007 I.: taas:,o. a. t7ODL E 1tCx i ct. uas 8 m C u O SQ u o t.v r •i t! l.Art I 1 LEGAL OESCR/PRON.• 4A J 1 . 4 Ic NOTE: I t BUILDING WILL BE STAKED AS SHOWN Lot 141, Kays Landing, Phase Z according to the Plat thereof, as recorded in Plat Book 69, at Page 43-44, of the Public Records, Seminole County, Florida. QONOTES. • (SKETCH AND LEGAL ONLY, NOT A SURVEY) ( 1. UNLESS IT BEARS THE SIGNAIURE AND THE ORIGINAL RAISED Z LANDS SHOWN HEREON WERE NOT ABSIRACIED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER IRIS BY CCL CONSULTANTS INC. FOR EASEMENTS AND DRAWING, SKETCH, PLAT OR MAP IS FOR INFORMATIONAL RIGHTS -OF -WAY OF RECORD, PURPOSES ONLY AND is NOT VALID. ADDITIONS OR DELETIONS 3. DATA SHOWN HEREON WAS COMPIL.O FROM OTHER v TO SURVEY MAPSORREPORTSBYOTHERTHANTHESIGNINGPARTYORPARTIES IS PROHIBITED WITHOUT WRITTEN INSTRUMENTS AND GOES NOT C(1YS17'UTE A FIELD SURVEY W CONSENT OF THE SIGNING PARTY OR PARTIESAS SUCH. C REVISIONS: DATE: BY: CL z PLOT PLAN 9/28/ 06 JAM 1 DAVI UNO, P. S. M PROFES7q6NAL SURVEY a MAPPER # 5670 STATE OF FLORIDA DATE 0 SKETCH. DRAW CHECKED FIELD 9 28/06 1BY JAM BY DM8 BOOK N/A J 1VJ114 .Z r, fjLYti`7Y Permit m Residential Swimming Pool, Spa a.nd Hot Tub Safety Act Notice of Requirements I (We) acknowledge that a new swim ng pool, spa or hot tub will be constructed or installed at `'1 Dn 5 j i . , and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida olease initial the method(s) to be used for your 000l 0E The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of Florida Statute 515.29; The pool will be equipped with an approved safety pool cover that complies with ASTM F1346-91 (Standard Performance Specifications for Safety covers for Swimming Pools, Spas and Hot Tubs); All doors and windows providing direct access from the home to the pool will be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at 10 feet; All doors providing direct access from the home to the pool will be equipped wits self -closing, self -latching devices with release mechanisms placed no lower than 54" above the floor or deck; i understand that noc having one of the above installed at the time of final inspection, cr -when the pool is completed for contract purposes, will consr tute a violation of Chapter -15. ;:.S. and will be considered as committing a misdemeanor of the second degree, punishable by fines up to S500 and/or up to 60 days in jail as established in Chapter 775, F.S'. Rt4jgODt%jS R 04 0 TrZACTO S SIG -NATURE 3 OATE OWNER'S SIGNATURE & OATc JO-Rsm-&&ram CO)NTP l,CTOR'S NAME ;PL—F-ASE PRINT) OWNER'S NAME (PLEASE PRINT) i 40'-0" 90S W o of ustom OFFICE q33d\ s SPE( f!5FICATIONS 3, ,, 3ool Dimensions: Size x ; Depth Special Depth — Nater Su a Area sq. ft.; Perimeter feet Filter Type ; Size / i0 Pump Type _ `t • Size Additional Pumps-- 1 v Size Return Inlets - No. Skimtner.(do.._L Sanitizing System I Heater - Type ; Size GAS LINE AND/OR TANK INSTALLATION AND HOOK-UP IS THE RESPONSIBILITY OF TH BUYER. VCleaningSystem __. Step/Bench Pkg. Other Plumbing t Water Feature 4- t0 Water Line Tile i`'l % Color ` V i X-0" Step Edge Tile _ S I ' Color LF7 4- Kai S LP>J t1't b tZ Raised Beam .M Coping LF ; Color Grab Rails & crefs Asteps U ; Hand -Rail Swimout 1.-x ;Bench x " : Step-out(s) N G Additional Bench, LF Underwater Light t Therapy Spa fS0 x ._; Sq. Ft. :Raised nce — —' Jet No. _ Spa Light _ Special Notes: — Notes: 1. Pool light switch located at I. Glass Block _ Deck Z l.1 _,;Sq. Ft. ;Color, T equipment Additional Deck Work -M P I"8 _sq. ft. I I Deck Pilasters L.F. _ 140 HeightlocationunlessotherwisesecifiedandpDeckStepsLr:— L.F. charged for. I Deck-O-Drain _— .F. ooti s L.F. Right !J' tQ Retaining Wall I l -C cE. i 41.; 2. Screen Frame - Bronze FLORIDA POOLS to remove on day of excavation: eep Pool Equipment on meter side of I Stumps - No. t, LConcrete/Asphalt Sq. Ft. Uprooted Vegetation and Other Debris house unless otherwise I Total No. of Loads to Remove Double Dirthandling T-SID— Pump from Street specified Buyer to have following to ted, rerouted or removed, as required: 3K I Septic Tank ;Ga r Line r Fl;n Note: Any window within 5'of the pool must have r Telephone Line ;Power Line ; Sewer Line EPIMAccess. Right (ft ( r ( ence Replacement ( ) es ( y Isafetyglassandistheowner's responsibilih' to O Per fission over next lot Permissionoverdrivewayhave installed. I/M-e have reviewed the above draining Sidewalk Replacement ( )'Yes (l.j fv0 end agree to It's design and Additional Grading Cu. Yds. C Water Source location Interior Pool Finish _ S Prepared For Designed By - Row ff Pv 4L*v Auto Controls 0 1123 Seminola Blvd Name: Engle Homes F% Casselbelry, FL 32707 Address: 11315 Corporate Blvd. MM Office: 407-696-2300 City/ST/Zip Orlando,Florida 32817 Fax: 407-696-2360 Subdivision: Kav's Landins I Lot # 141 ne: 386:789.4237 SCALE ee: 1 /8" = 1'0 ' SiSi nat Date Additional Electrical Ile: ' TAYZ ( Screen Enclosure or er: rch Signature Date Roof _Door Gutte s Child Safety Fence St ..t )f: g SJ 1. FOR POOL PLAN, SIZE, DECK SPECIAL DETAILS SEE CONTRACTOR'S POOL PLAN. 2 POOL WALLS SHALL BE 5" THICK AND FLOORS SHALL' BE 6" THICK AND SHALL BE PNEUMATICALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 3.000 PSI IN 28 DAYS. CONCRETE DECK SHALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318. 3. ALL POOL CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING CODE BUILDING 2004, FLORIDA BUILDING CODE RESIDENTIAL 2004, ANSI NATIONAL STANDARD-5 FOR RESIDENTIAL INGROUND SWIMMING POOLS, AND ANSI/NSPI NATIONAL STANDARD-3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS. 4. ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. 5. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40. REINFORCING SHALL BE # 3 BARS AT 12" O.C. EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO 6'. OVER 6' USE #3 BARS AT 6" ON CENTER EACH WAY IN THE AREA OVER 6'. IF CONCRETE IS CAST AGAINST BARE EARTH WITHOUT A SEPARATION BARRIER, MINIMUM COVER SHALL BE 3". WITH A BARRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER, SHALL BE 1 %". 6. ALL METALLIC POOL FITTINGS WITHIN 5 FEET OF THE INSIDE WALL AND DECK REINFORCING STEEL TO BE BONDED TO THE POOL REINFORCING STEEL WITH #8 AWG COPPER WIRE. #8 AWG COPPER WIRE TO BE RUN INTERNALLY AND EXTERNALLY WITH THE NEC APPROVED PVC LIGHT CONDUIT FROM THE LIGHT NICHE TO THE JUNCTION BOX. COMPLE11ON OF POOL GROUNDING TO PANEL GROUND BY ELECTRICIAN. 7. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR CLEAN SAND, WHICH SHALL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY, ANY UNSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN IT'S ENTIRETY AND THE AREA SHALL BE BACKFILLEO WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. 8. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS IF REQUIRED. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 9. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. IQ CONTRACTOR SHALL DETERMINE LOCATION OF ALL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIONS AN ORDINANCES. 1 CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUND CONSTRUCTION AREA TO PREVENT UNAUTHORIZED ENTRY INTO AREA. 12 IF A WATER SUPPLY IS PROVIDED, A MINIMUM 3" ATMOSPHERIC BREAK WILL BE PROVIDED. 11 ALL STRUCTURAL FILTRATION, AND ELECTRICAL DETAILS OUTLINED IN THESE DRAWINGS ALSO RELATE TO SPA CONSTRUCTION. It ALL POOL AND SPA HEATERS SHALL BE EQUIPPED WITH AN ON —OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW 'THE HEATER TO BE SHUT OFF WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. I& SPAS AND HEATED POOLS SHALL HAVE A COVER DESIGNED TO MINIMIZE HEAT LOSS UNLESS 70% OF THE ENERGY FOR HEATING IS DERIVED FROM NON—DEPLETABLE ON —SITE RECOVERY SOURCES. I& THERE SHALL BE ADD SAFETY GLAZING IN DOORS AND WALLS OF ENCLOSURES FOR HOT TUBS, AND OTHER SUCH FACILITIES WHERE SUCH GLAZING IS LOCATED 36' OR LESS FROM A STANDING OR WALKING SURFACE WITHIN THE ENCLOSED AREA OR LESS THAT 60" ABOVE THE FLOOR OR WALKING SURFACE. T7. WARNING! TO EMPTY THE POOL FOR ANY REASON, THE HYDROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. R UNE/ I UGHT 6' TILE / 6' MAXIMUM RISER - 12' 1 MAXIMUM TREAD = TO" (240 S0. IN.) DUAL SUCTION OUTLET (OPTIONAL) SET INTO CENTER OF STEEL GRID AT POOL DEEPEST POINT W/ 3' SEPARATION LONGITUDINAL POOL SECTION BRICK COPING 6"X6' TILE SPILLWAY WIDTH SEE PLAN) WATER LINE 6-X6" GLASS BLOCKS MOUNTED IN 2500 PSI CEMENT (IF SPECIFIED) 3AT12"O.C.EAWAY RAISED SPA DETAIL MUSED' 2 SOIL (NO VOIDS) TYPICAL SWIMOUT DETAL VARIES - SEE PLAN THERAPY 3 AT 12" SEAT O.C. EA. WAY_j 4' , m RETURN 1ST SPECIFIED) 6 1' GUNITE 1REBOUND 2-8' 0 ANTI —VORTEX DRAINS SEPARATED BY 3' SPA SECTION THE FOLLOWING TABLE PROVIDES MAMMUN FLOW THROUGH PVC PIPE WITHOUT EXCEEDING THE MAXIMUM STANDARDS FOR VELOCITY (FT/SEC) N 1 50 GPM 65 GPM H 2' 85 GPM 105 GPM 2 HP 2 31 125 GPM 150 GPM 2 1/2 HP PUMP SIZE BASE, ON A TOTAL DYNAMIC HEAD (TDH) OF 50' AND FOR ESTIMATE ONLY. ACTUAL PUMP SIZE WILL VARY OEPENOING ON THE PUMP SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE SPECIFIC POOL NEEDS SURFACE SKIMMER AOOITIONAL /3 REBAR REDO AT SKIMMER OPENING WALL SEC110N AT SKIMMER , 1 #3 BAR CONT. W/ 4" NOM. "FIBER MESH' CONCRETE DECK W/ SUP 5" WALL—W/ 8-X8" BOND RESISTANT TOPPING ON COMPACTED GROUND BEAM USE 2 #3 BARS CONT. W/ ALL ORGANIC MATERIAL REMOVED (OPTIONAL) - V MIN. JUNCTION BOX 8' MIN. BY OTHERS) 18' MIN. TO TO TRANSFORMER BY OTHERS) TOP OF LENS MARBLE OUTER EDGE OF DECK TO CONFORM WTH LOCAL CODEPLASTERFINISH REFER TO ATTACHED DRAWING U.L. APPROVEO 120 VAC/30OW POOL LIGHT W/ FOR DATA REGARDING OVAL CFI OR 12V/30OW POOL LIGHT W/ LOW WATER SUCTION OUTLET SYSTEM AND CUT OFF IN U.L APPROVED GREY PLASTIC VACUUM RELIEF SYSTEM FORMING SHELL W/ y8 BONO PER N.E.C. 3 BARS 12' O.C. EACH WAY STEELTEX FORM (OPTIONAL) POOL STRUCTURAL DETAILS 1. MAIN DRAIN LINE 1 %_ • =1 •1 2. SKIMMER LINE 6 E / 3 3. WASTE LINE 4, RETURN LINE Y iJ 5. PRESSURE CLEANING I i D LINE (OPTIONAL) 16 AWG COPPER WIRE TIMECLOCK WDECK ANEL SERVICESPST Box TOGGLE 5 4' MIN. SWITCH < W.P. DISC 4 PUMPPOOL12VTRANS 3 /12 IN %' COND 12 V/300 W W/ LOW ALL ELECTRICARMS REVIEWED WATER CUT-OFF SHALL CONFOf OF 5AN RDOR120V.A.C. W/ CFI W/ ART. 680 (,`rPERN.E.C. N.E.C. 2002 ELECTRICAL DIAGRAM S'X8' BOND BEAM 2 #3 BARS CONT. MIN. 1 )j" COVER OVER ALL BARS SEE NOTE J! s" TILE e 5 w DISTANCE 1 5 —I 5' G LL BRICK 1 ROW I DECK OVERPOUR LESS THAN EXISTING ON 1 + I STRUCTURE ALTERNATE BEAM FINISH DETA 6' THICK WALL 3 BARS AT 6' O.C. EACH WAY STEELTEX FORM MARBLE PLASTER FINISH THE CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6' ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED AT 6" THICKNESS. THE STEEL MAT AND SHELL WALL SHALL BE EXTENDED ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED DISTANCE AS OLTERMINED BY THE 1 ON 1 + 1 METHOD. TYPICAL WALL AND FLOOR WITHIN ANGLE GF REPOSE SEP 2 1 NO 6A E I I GO N H. TIE .R0SON, P.E. FL. E. NO3 9333 1717 GOLFSIOE ORWE WN TER PARK, FL 32792 PHONE: (407) 657-4133 FAX: (4071 6;T7-4133 C B A. HAIR do LINT STRAINER B. RECIRCULATOR PUMP A C. FILTER 0. IN—UNE CHLORINATOR OPTIONAL) E. HEATER (OPTIONAL) 2 VALVE I F F. ANTI ENTRAPMENT SYSTEM FILTER SYSTEM 28' MIN. PER MANUFACTURER SPEC LADDER TO BE CROSS BRACED PER MANUFACTURER'S SPEC. ALL LADDER TREADS SHALL HAVE SUP RESISTANT FINISH WEDGE ANCHOR AND ESCUTCHEON 3' MIN. 6' MAX BETWEEN TREAD AND POOL WALL TYPICAL SWIMMING POOL LADDER SECTION VACUUM LINE vw SAFETY vACuum RrnNo 15{ y VE I VACUUM LINE OPTION AU VW SAFETY VACUIN FrrnaG \ VE I VACUUM LINE OPTIONWJ V0 SAFETY VACUUM NG \ u SK...EII rw r: 1r " RESIDENTIAL SWIMMING POOL, SPA AND WADING POOLS DUAL SUCTION INLET SYSTEM &'VACUUM RELIEF SYSTEMS ' IN ACCORDANCE WITH SECTION 424.2.6.6 OF FLORIDA BUILDING CODE r! ANTIVORTEX r cove` r a SUCTION *SA M MANIORAMM spot LNG POOL °""° SECTION VE I 9L¢ r a SUCTION OXEN WAN ORAW6j r YAR 1r ANTIVORT}x COvol r a SW*A6MG POOL SECTION ALTERNats -g. SWIMMING POOL SECTION - COVER MUST COMPLY WITH Al/SYASMEAtILISA Y 11 I I ra a SUCTION +aura MAN ORAMM alAY9 SPA SECTION AL NA 'A SKMAN10 AmnvORTEX COVER SPA r 11A - VE 1• ra SUCTION uAET YAW ORPJM SPA SECTION ALTERNATE 'H' AN APPROVED VACUUM RELEASE SYSTEM SUCH AS THE VAC - ALERT."' SVRS SYSTEM IS AN ALTERNATIVE VACUUM REI-IEF DEVICE, INSTEAD OF EITHER OF THE TWO SYSTEMS SHOWN. ATTACH PLACI(ARO %"ICH STATESTHATVENTISASVWMMINGPOOLSAFETYDEVICEAN() SHOULD NOT8ETAMPEREDWITH. ALTERNATE SUCTION rr 3YSTT3N MAY WCLIIDE 1 ON THE BOTTOM AND ONE ON THE wExTlcu rYA Da ONE EACH ON TM (21SEPARATEVERTUdWALLA VENT COVER MAY BE CUrrER VENT TO ATMOSPHERE SO VENT MODEL 1aAHAYW S aaECT INFESTVIIIILL NOTBE BYOEBFIfS, MCNOEOl. OGw.AL CONTALumATION b W ELSOM r er MINIMUM ALTERNATE rIa I T r e f 3UCTION INLET MAXaKW OQTANCE r 0 TO VENT TEE CONNECTION 1' 0 ALL 3UCTION t TO PUMP m Z. a MAX AJM SUCTION PIPE VELOCITY 30: ( 4) FPS OR n CPU 15i' B VENT PIP\E q/ 3. II A Ir Ml, SUCTM , K'. . Il Iw3HED GRADE ALL VENT SUGGESTED PPIYO. IK-o DETAIL ATMOSPHERIC VEW PIPE IU4GTH MtIaIIllAl1- IV ORAVWNG TO SUPPLEMENT k • CONTRACTOR' S SPECIFICATION ORAVWNGONFILEABOVY WWMIUM VACUUM VWTH ONE P PLUGGED AND TO RELEASE OVAL SUCTION INLET SYSTEM ENT ON THE OTHER P VWLL NOY EXCEEDED 43 ATMOSPHERIC VENT SYSTEM ES OF MERCURY IN 3 SEOONDs 1) VERTICAL TOLERANCE Is • r 1) WATER LEVEL MARK 1- TO PUMP 4' 8Y4" > SEP 2 1 2005 1717 GOlFS1OE ORP IE WINTER PARK FL 32792 PHONE ( 4(M a57-4133 FAX ( 40n a57-4133 DECK_ H J a a SUCTION FLOW FOR RESIOENTUIL POOL = 8 FPS SUCTION FLOW FOR RESIDENT AL SPA = 6 FPS CONTRACTORMAYSUCTIONPIPESIZETO MEET THESE REQUIREMENTS MAX ' L' TO MAIN WATER LEVEL F- Y MIN.. -I L4- 1 19' 742S 2' 2.A'IT 31' 2 % 3' v 4a 3' 4' SS 4' 5' 12' 77 5' 8' 14' PIPE LENGTH TO VE If `L" - ELBOW FRICTION LOSS EXAMPLE: THE MAXIMUM PHYSICAL PIPE LENGTH FROM MAIN DRAIN TO VEII IF USE 2' 0 PIPE W/ 2-9(r ELBOWS AT 6 FPS IS 54' -12' = 42' VACUUM SUCTION ELIMINATOR - VE II AVE II IS REQUIRED FOR EACH PUMP PLUMBED TO A MAIN )RAIN P116 "*R* aCentral Honda, Inc- 1123 SEMINOLA BLVD CASSELBERRY, FL 32707 MASTER DRAWING NOT TO SCALE OWD 9Y- GHS 12" to 24" DECK TURNDOWN --- RETAINING WALL- - The ground drops off going towards the back yard so that the existing ground is approximately 12" 'to 24" lower than the proposed pool deck. The contractor proposes to "turn down" the deck along the backside of the deck and the side towards the house as far as it is needed. The contractor proposes a monolithic pour of the turndown area and the remainder of the deck using a fiber additive in the concrete. In the area of the turndown, the contractor proposes that the wall will be 8" thick and contain 145 reinforcing bar in its base and 143 bar at the top of the turndown and 143 bar vertically at 36" on center between the horizontal # 3 bar and the horizontal # 5 bar. When the base of the turn -down extends into the original around soil, a pilaster will not be required. They will install 4" diameter pilasters every 5 feet under the turndown and as a part of the turndown that will be either 2' into the ground or to the indigenous material, which ever is deeper. They will also install a #3 reinforcing bar in the pilaster and tie it into the reinforcing bar in the base of the vertical pour. All other construction procedures and specifications will be in accordance with the contractor's specification sheet on file with the building department. Based on this data, I feel that the construction procedure to be utilized in this instance complies with sound construction practice, is in accordance with the Florida Building Code, Building 2004, and Florida Building Code, Residential 2004 and will not derogate the quality of the pool deck being constructed for the home owner and is acceptable. IMPORTANT NOTE, A DECK TURNDOWN IS NOT INTENDED TO BE A SUBSTITUTE FOR A RETAINING WALL. IF THE VERTICAL DIMENSION FROM THE TOP OF DECK TO THE OLD GROUND EXCEEDS 2'6" (FOR A 12" TURNDOWN), 3' (FOR AN 18" TURNDOWN), OR 3' 6" (FOR A 24" TURNDOWN) FOR MORE THAN 20 % OF THE TURNDOWN LENGTH OR THE FINISHED GRADE SLOPE EXCEEDS 4' HORIZONTAL TO 1' VERTICAL, A TURNDOWN SHOULD NOT BE USED. 4" CONCRETE OECK COMPACTED 8MATERIAL 1- #5 REBAR- t CONTINUOUS 4" 0 PILASTER MAX EVERY 5' WITH 11 r_ 1-# 3 REBAR —1 6" MIN NOT TO SCALE T NOM. 4) TYR GRADE NO FOOTER LEVEL TERRAIN RIBBON FOOTER-WHERE FOOTER IS NOT CONNECTED TO DECK - El USE 8%8' CONCRETE RIBBON FOOTER W/ 1#5 REBAR CONTINUOUS TO SUPPORT UP TO 2" X 6" UPRIGHT 1) 2) 3 BAR 3) CONTINUOUS 1 # 3 BAR VERTICALLY TAT 36" ON CENTER 12" to 24" TURN -DOWN 4' OR FLATTER FINISHED GRADE. 22' va t1=11=It=1 t1- OLD GROUND TYPICAL SECTION -DECK TURN -DOWN i FOUTILK W/ SLOPE BETWEEN 1' IN 6' TO 1' IN 3' a USE 8"x 12- CONCRETE RIBBON FOOTER W/ 2 # 5 REBARS CONTINUOUS TO SUPPORT UPRIGHTS LARGER THAN 2" x 6- FOOTER SWILL BEAR ON ROCK CLEAN SAND, OR STRUCTURALLY SOUND SOIL (>1500 PSI:) THAT SWILL BE COMPACTED TO PROVIDE OPTIMUM BEARING CAPACITY TO PREVENT SETTLING. CONCRETE SHALL PAVE A 28 DAY STRENGTH OF 2.500 PSI W/ FIBER MESH OR sx6-1000 w W MESH. V1E E0 ' 3 - J3 BARS IS EQUIVALENT TO 1 /5 BARS. ROQofSaN CONTRACTOR MAY USE: 3- # 3 BARS FOR 1 # 5 BAR c ( a 0/ CONE. CONT. FOOTER WHEN SLOPE 1' IN 3' OR STEEPER OR WHEN DECK EXTENDS 33' OR MORE PERPENDICULAR TO THE SUPPORTING STRUCTURE. FOOTER WHEN SLOPE 1' IN 3' OR STEEPER OR WHEN DECK EXTENDS 33' OR MORE PERPENDICULAR TO THE SUPPORTING STRUCTURE. TYPICAL SCREEN DECK FOOTER DETAILS NOTE: IF A SCREEN ENCLOSURE IS TO BE BUILT, THE SWIMMING POOL CONTRACTOR SHOULD COORDINATE CONSTRUCTION OF ANY REQUIRED FOOTER WITH THE SCREEN ENCLOSURE CONTRACTOR. VALID FOR ONE YEAR FROM SIGNATURE DATE SEP 2 1 _2005 IDATE GOP, N H. S EVROSON, P.E. FL. NO. -I 333 1025 OUTH SEMORAN BLVD WINTER PARK, FL 32792 PHONE: (407) 679-9188 F6*'0ruwF of Cents! FIc.nda. Inc. 1123 SEMINOLA BLVD CASSELBERRY, FL 32707 MASTER DRAWING IVOT TO' SCALE OM BY-- GHS