Loading...
HomeMy WebLinkAbout1500 S Elliot StCITY OF SANFORD PERMIT APPLICATION Application # : 0-7 Submittal Date: � 0 % Job Address: ISoo Jr E lI t A d4ee+ Value of Work: S i aCO Parcel ID: 31 ►q 31 Sol O Poo 0 1 qo Zoning: S_1 Historic District: A//A Description of Work: Square Footage: ........................................................................................................................ Permit Type: Building d Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler/Alarm ❑ Pool ❑ Sign ❑ Electrical: New Service — # of AMPS .Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Occupancy Type: Residential 5( Commercial ❑ Industrial ❑ Plumbing Repair — Residential ❑ Commercial ❑ Occupancy Use Group(s): Construction Type: ,$ FR_ M of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ........................................................................................................................ Property Owner: AnAcae, i'WilIIArns Contractor: RL R Con.S�fRc4i9rx Address: � 0 Q 1, . �� i O �' ��rCeT Address: 'CA r4k t4 Ave SarSoPA 5 FL y'3,t?�1 1 5gnfordi, FL 3� 7-1 l Phone: t'(E-mail: Phone: L1417-330-71 4StateLicense Number: L8C l� / 5 /(Sy Bonding Company: Al/A Mortgage Lender: AIM Address: Architect/Engineer: !y/i Address Plan Review Contact Person: .Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN .ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirem nts f Florida Lien Law, FS 713. ;z5 A SignatureofOwner/Agent Date Signal.eofContracto Ager' Date Print Owner/Agent's Name Prin ntractor/Agent's N e q 1251a y Signature of Notary -State of Florida Date Si ature of Notary -State o Florida Date \\\\��\\\111T ��%j�/�// �\ 'A ....s /ice �� �. •MMI SSI0^, Owner/Agent is Personally Known to Me or Contractor/Agent is rson _ Produced ID Produced' jID A% 1 }� 1; 4i �f j p. O N APPROVALS: ZONING: UTIL: FD: ENG: '� Z • o �. Special Conditions: i9�4 •'" °'nP m,°, 44�. •Q Rev 07.07 �///e§r' S1G±E JELDIvEIv® PREMIUM FIBERGLASS DOOR OUTSWING 84 6 6-E FLUSH GLAZED GENERA NOTE 1. THIS PRODUCT IS DESIGNED TO MEET THE 2004 FLORIDA BUILDING CODE. 2. WOOD BUCKS BY OTHERS. MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 4. IMPACT RESISTANT SHUTTERS ARE REOUIRED 5. DESIGNED PRESSURE RATING SEE TABLE I, PACE 1. 6. SIDELITES ARE AN OPTION AND CAN BE IN A SINGLE OR DOUBLE CONFIGURATION. 7. THIS PRODUCT MEETS THE WATER REOUIREMENTS FOR HIGH WIND ZONE VELOCITY AREA ' RESIDENTIAL FIBERGLASS DOOR (Common to all frome conditions) Door Leaf Construelbn• Face sheets: Fiberglass avg. min. yield strength Fy(min.)=6,600 psi Skin — 0.065" nominal Core design: Expanded Polystyrene foom core, with 1.0 to 1.25 Ibs./cu. ft. density. Panel Gonsfructlan: The panel skin is constructed from a 0.065" nominal fibergloss skin. The panel face sheets are glued to a wood bottom roil and LVL top roil do stiles. In the double door application the noctive door is fitted with an extruded aluminum astrogal (Endura) of 6063-175 alloy. Sid lire Construction Panels are sandwich glazed using a two piece plastic lite frame with mitered and welded or glued comers. Glazing consist of two 0.125" tempered panes separated by a 0.50" air space. The lite frames are wet glazed on the interior and exterior side with Dow Coming 1199 sealant.• Frame C-Anstruction: The fromes are constructed of finger—jointed pine jambs measuring 4-9/16" x 1-1/4". The threshold and head jamb are mortised and butt joined to the side jambs with one (1) 16CA 7/16" crown x 2" long staple and two (2) 110 x 1-1/2" PFH screws on each side. TABLE OF CONTENTS SHEET #1 DESCRIPTION 7ti5.fi15 MAX. UVLKALL f-KAME WIDTH 37.75" MAX. FRAME WIDTH 36" MAX. rPANEL WIDTH PANEL WIDTH 36" MAX. W/ ASTRAGAL PANEL WIDTH 20.5" 20.5" t- Q AX. D..0. 1— _ w = � W Z W m WY�co 14" W � MAX. J W z WIDTH rl�i Y a 0 MAX. o Q O O O 0 ACTT X Co X IN rn rn 15 O r� 1 0(3 mEh2 ' a 7ti5.fi15 MAX. UVLKALL f-KAME WIDTH 36.75" MAX. PANEL WIDTH 36" MAX. W/ ASTRAGAL PANEL WIDTH 20.5" J �. J 0 to MAX Z W m WY�co 14" �Sa�r MAX. D. WIDTH rl�i Y a 0 MAX. o yr I ACTIVE 0 ACTT y Co O O r� 1 0(3 mEh2 ' a O j INA tIVE VACTIVf SINGLE OUT -SWING UNIT 8-0 SYSTEM 1 4 11 a REF. DETAIL A, SHEET 4 DOUBLE OUT -SWING UNIT WI-SIDELITES 8-0 SYSTEM ALL DOOR MODELS ARE VIEWED FROM THE INTERIOR SIDE DOUBLE DOOR PRESSURE RATING AND SINGLE DOOR WITH SIDEUTES WHERE WATER INFILTRATION REQUIREMENT IS NEEDED POSITIVE +45/+55• NEGATIVE—45/-55* -PRESSURE RATING WITH SURFACE BOLTS DWO• 13Y." J.TOWNE a«. IN: R.CLARK DPAWM n0.: JW0162006-1 SHEET _1 OF 15 0 J �. J 0 to Z O J � W Z W m WY�co 14" �Sa�r MAX. r^i WIDTH rl�i Y a 0 MAX. o D.L.O. 0 X Co KV O r� � O 0(3 mEh2 ' a 1 4 11 a REF. DETAIL A, SHEET 4 DOUBLE OUT -SWING UNIT WI-SIDELITES 8-0 SYSTEM ALL DOOR MODELS ARE VIEWED FROM THE INTERIOR SIDE DOUBLE DOOR PRESSURE RATING AND SINGLE DOOR WITH SIDEUTES WHERE WATER INFILTRATION REQUIREMENT IS NEEDED POSITIVE +45/+55• NEGATIVE—45/-55* -PRESSURE RATING WITH SURFACE BOLTS DWO• 13Y." J.TOWNE a«. IN: R.CLARK DPAWM n0.: JW0162006-1 SHEET _1 OF 15 Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 2 PARCEL DETAIL, s DAVID JOHNSON,. CFA, ASA PROPERTY AiPP11AISER SEMINOLE 0O(JNTY:F1_ 1101 E. FIRST s -r 9ANF03i6,. FL 327 1-1468 407-665 '/7508 2007 WORKING VALUE SUMMARY Value Method: Market GENERAL Number of Buildings: 1 Parcel Id: 31-19-31-501-OF00-0190 Depreciated Bldg Value: $109,360 Owner: WILLIAMS TAMIKA Depreciated EXFT Value: $840 Mailing Address: 1500 S ELLIOTT ST Land Value (Market): $36,565 City,State,ZipCode: SANFORD FL 32771 Land Value Ag: $0 Property Address: 1500 ELLIOTT ST SANFORD 32771 Just/Market Value: $146,765 Subdivision Name: BUENA VISTA ESTATES Assessed Value (SOH): $73,272 Tax District: S1-SANFORD Exempt Value: $25,000 Exemptions: 00 -HOMESTEAD (1994) Taxable Value: $48,272 Dor: 01 -SINGLE FAMILY Tax Estimator Tax Reform Analysis 2007 Notice of Proposed Pro er y Tax SALES 2006 VALUE SUMMARY Deed Date Book Page Amount Vac/Imp Qualified Tax Amount(without SOH): $2,111 WARRANTY DEED 05/2007 06702 1985 $155,000 Improved Yes 2006 Tax Bill Amount: $915 WARRANTY DEED 11/1988 02021 1142 $40,000 Improved Yes Save Our Homes (SOH) Savings: $1,196 QUITCLAIM DEED 10/1988 02011 1248 $100 Improved No 2006 Taxable Value: $46,485 Find Comparable Sales within this Subdivision DOES NOT INCLUDE NON -AD VALOREMASSESSMENTS LAND LEGAL DESCRIPTION Land Assess Frontage Depth Land Unit Land Units Price Value PLATS: Pick... 0Method FRONT FOOT & LEG LOTS 19 + 20 BLK F BUENA VISTA DEPTH 100 150 .000 355.00 $36,565 ESTATES PB 3 PG 2 BUILDING INFORMATION Bid Bid Type Year Bit Fixtures Base SF Gross SF Living SF Ext Wall Bid Value Est. Cost New Num 1 SINGLE 1948 6 884 2,359 2,103 CONC $109,360 $178,547 FAMILY BLOCK Appendage / Sgft OPEN PORCH UNFINISHED / 256 Appendage / Sgft BASE SEMI FINISHED / 559 Appendage / Sgft BASE SEMI FINISHED / 80 Appendage / Sgft BASE SEMI FINISHED / 108 Appendage / Sgft BASE SEMI FINISHED / 472 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished,Base Semi Finshed Permits EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New FIREPLACE 1979 1 $600 $1,500 http://www.scpafl.orglweb/re web.seminole_county_title?parcel=3119315010F000190&c... 9/25/2007