HomeMy WebLinkAbout1903 S Palmetto AveCITY OF SANFORD PERMIT APPLICATION
Application # : &0- 3 S <
Job Address: M 3 5'- Va l wi hn 4 y c
Parcel ID: - .30 - 5-/ / - OJ -00 - VW Cloning:
Description of Work: -J()C ZQ Sb Q it
Submittal Date:
Value of Work: $ 21 op -00
Historic District:
Square Footage:
........................................................................................................................
Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing x Fire Sprinkler/Alarm ❑ Pool ❑ Sign ❑
Electrical: New Service - # of AMPS
Mechanical: Residential% Non -Residential O
Plumbing/ New Commercial: # of Fixtures
Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑
Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required)
# of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential 0 Commercial ❑
Occupancy Type: Residential 1W Commercial ❑ Industrial ❑ Occupancy Use Group(s):
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required)
.............................................. ........................................................
Property Owner: ���,1 l -e le -v- Contractor: aLA_P's V— I UV S() (ali eL�
Address:1. . G4, Address: � '1:� 'I-kAv-]+
PhonA77(D 4 00to E-mail: Phone: gSt
ate License Number: CVC05�ao 3G
70- 71Bonding Company: Mortga
Address: Address:
ArchitectlEngineer:
Address:
Plan Review Contact Person: Phone: Fax:
Phone:.
Fax:
E-mail:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning- WARNING TO OWNER- YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements Li Law, 71
Signature of Owner/Agent Date Signature of Contractor/Agent Date
Print Owner/Agent's Name Print oniractor/Agent' Name
Signature of Notary -State of Florida Date Si ' f No ary-State of Florida Date
NOTARY PUBLIC -STATE OF FLORIDA
Owner/Agent is —Personally Known to Me or
Produced. ID
APPROVALS: ZONING:. UTIL:
Special Conditions: _
Rev 02/2007
FD:
/ Jennifer McKinney
Commission # DD549592
Contractor/Agent is _Personally K 8&'_ ires: 06/ 4/2010
Produced ID 1'•Y p y/Jf
ENG: BLDG:
MOUJW71JWG TIME SOLAR PANELS
Ushvc
m ,,
}e ._: CLAMPS
installationThe beauty of the "GATOR CLAMP"
of roof or rack installation.
MOUNTING THE SOLAR PANELS USING ALLIGATOR CLAMPS
HC -110 ALLIGATOR CLAMP
PANEL HEADER (TOP) \
HC -1 13T PANEL CLAMP TOP
HC -113L LATCH
"' HC -1138 PANEL CLAMP BOTTOM
For rack systems, asphalt shingle roofs or tile roofs follow these simple steps:
1. Snap a chalk line across the roof or rack where you want the top edge of the collectors to be located.
Since the panels should slope slightly down toward the feed end of the array for proper drainage, the
chalk line should also slope down in this direction approximately 1 inch per 20 feet.
2. Position the first Gator Clamp on the chalk line 6 inches in from the top corner of the first panel. The first
panel will be the one that is connected to the feed line at the bottom header.
3, Subsequent Gator Clamps should be spaced out evenly along the chalk line every 24". Each Gator
Clamp can be located anywhere along the top header to match up to the spacing of the roof rafters as
long as there is a 2" space between the edge of the Gator Clamp and the ribs on the panel header
that exist every one foot. This allows for horizontal expansion and contraction. For Barrel Tile roofs,
each Gator Clamp needs to be positioned so that it is centered on the top ridge of a tile.
4. Since normal horizontal expansion and contraction of an array of panels takes place every day as panels
heat up and cool down, it is preferable to lock the center of each array in place so that the expansion and
contraction takes place evenly to the left and right of this center point. The center panel of an array may
be locked in place by locating the Gator Clamps on that panel adjacent to the left and right of one of the
header ribs. (See Figure 5.5) These Gators should be attached using two lag bolts as opposed to one.
Do not use this procedure more than once on any array of panels.
5. Apply ample sealant to both the bottom and top of the lower hole on the bottom portion of the Gator
Clamp. (Figure 5.7A) Position the bottom portion of the Gator Clamp perpendicular to the chalk line with
the lower hole being placed right on the chalk line. Lag the Gator to the roof through the lower hole using
a'/4" X 2" S.S. Lag Bolt. (Figure 5.76) For Barrel Tile Roofs, place 4 HC-11OBTS Barrel Tile Spacers
underneath each Gator Clamp by inserting the four feet of the Barrel Tile Spacer into the four corners of
the bottom of the Gator Clamp. (Figure 5.8)
6. The bottom of the Gator is designed to grip the roof's surface to avoid rotation back and forth; however,
if the roof surface is particularly hard or slick you can use an additional lag bolt in either the top or center
hole.
7. To ensure proper spacing, hang the top headers of panels in the bottom portion of the Gators attached
to the roof as you go. Once again, be.sure Gator Clamps are at least 2" away from each ridge along the
header. (Figure 5.7D)
8. Once all Gators are properly lagged to rack or roof surface, and all the collectors are hung in place,
connect the top headers of each collector using HC -113 Panel Clamps. Snap the top portion of each
Gator Clamp overthe panel header onto the bottom portion of each Gator Clamp by pushing down firmly.
(Figure 5.7C)
12
-7MM : UNA
FEB. 19. 2002 11:57AM P 3
PHONE NO. : 0813 572 7922
SUMMARY INFORMATION SHEET
FLORIDA SOLAR ENERGY CENTER L
1679 CLEARLAKE ROAD, COCOA, FLORIDA 32922-5703 (321) 638-1000 September 20
(`SEC #t 000130
MANUFACTURER 'Revised October 2400
Model
Weliocel U.S.A, Inc, - Magen Plastic CopectOr Hellocol 40
927 Fern Street, Suite 200
Altamonte Springs, Florida $2701
This Solar coliwor was evaluated by the FlOrld$ Solar E"rgy Center (FSEC) in accordance with prescribed methods and was found to merit
the minimum standards established by FSr=C, This svglyatf on WU basad on solar collector tests
perfornlod at the Fiord$ Solar Energy Cantor,
Cocoa, Florda. The purpose of the tests Is to verify Initial performance cond6ons and quality of construadon only. The resulting oertification
Is not a guarantee of long term performance or durability,
DESCRIPTION
-
Gross Length
3,228 meters
10.58 feet
Gross Width
1,172 meters
3.84 feet
Gross Depth
0.040 meters
0.13 feet
Gross Area
Transparent Frontal Area
3,778 square meters
3.779 square meters
40.68 square feet
Volumetric Capacity
11.7 liters
40.68 square feet
3.1 gallons
Weight (empty)
Recommended Flow Rata
8.6 kilograms
315 mils
19.0 pounds
Maximum Operating Pressure
207 kpag
5.0 gpm
30 prig
Maximum Wind Load
Not Applicable
Number of Cover Plates
None
Flow Pattern
Parallel Forced Circulation
Number of Flow Tubes
Multitube mat
MATERIALS
Enclosure None
Glazing None
Absorber Polypropylene with W stabilization
Absorber Coating None
Insulation None
THERMAL PERFORMANCE
—
Tested per ASHRAE 96-1980 (RA 1989)
Incident Angle Modifier Ktct = 1.0 - 0.11 ( 1 .1) 1
Efficiency Equations
71 = 82.8 - 1852 (N-Ta)/1
. tl = 82.8 - 326 (fi-Ta)/l
rl = 831 - 1844 (Ti-Ta)/l - 5069 [(Ti--ra)/I]e ri 83.7 _ 324 (Tl -Taj/! - 157 [(Ti-Ta)/1]2
Units of Ti -Tall are °C / Watt/m2 Units of Ti -Ta are °F / Btu/hr.ftz
_ - RATING
The collector has been raW for energy output on me"uredperformance and an assumed standard day. Total solar energy avallable
for the standard day Is 5045 Watt-hour$/me (11 WO Btu/fte) distributed over a 10 hour period.
Culprit energy ratings for this collector based on the Second -order efficiency curve are:
Caiiector Temperature
Energy output
Low Temperature, 35°0 (95oF) 41,000 141o]oules/day 38,900 Btu/day
Intermediate Temperature, 6000 (1220F) 14,700 Klo]oules/day 14,000 Btu/day
High Temperature, 100*0 (2120P) 0 Klojoules/day 0 Btu/day
REFERENCE 98002
------
33555
SOLAR POOL HEATING. ENGINEERED FOR LJFE
1109. Attach the bottom headers of the collectors with HC-113�Panel Clamps.
. Attach feed and return lines following Heliocoi's published guidelines.
11. Be sure all four corners of the array are securely fastened to the roof. The corners where the feed and
it return lines are located should be fastened down by Pipe Straps that are also supporting
the pipe. The corner above the feed line should be attached to the roof b the Gator Clamp supporting
eight of
the header. The corner below the return line should be supported by the HC -137 J -Clamp that comes
in the Row Kit. Locate this J -Clamp 3" to the inside of the end of the an p pp°rt(ng
a '/z" gap between the J -Clamp and the bottom of the header. (Figure 5.6)
long the header. Allow for
ALLIGATOR CLAMPS
PPC PPC
PPC G or C CLAMP
PPC (To support Plumbing)
- -----------------
G or C CLAMP
(To support Plumbing) J -CLAMP
Figure (5.4)
NOTE:
I;,JOTE:
NOTE:
Figure (5.8)
Figure (5.5)
Figure (5.6)
GAP
Figure (5.9)
*Additional Gator Clamps are required for surfaces with a pitch of 10/12 or greater.
Additional Gator Clamps maybe used along the bottom header as desired. To allow for vertical
expansion and contraction, any Gators Installed on the bottom header rn t beitl
that the header Is In themiddle of the cradle. (Figure 5.9) pos--QOM
As the Installing contractor, it is your job to evaluate any site specific conditions that might
create unwanted roof wear. As an example, If you are installing the system on an inexpensive
orsoftasphalt shingle roof, you'll want to put some 4" by4" pads underneath each clamp along
the bottom headers to prevent roof wear. Some installers make these pads from aluminum roof
flashing or old mat systems, and attach them to the roof with silicone or an adhesive.
A g
Figure (5.7)
Ce
C
13
NOW ao, 3t�a �.fT^3' F... ._ £•-s_ -_
4�_ at ',.' "� - fid'.
o VO
, -R Exlqrtpjc P1I $_ ' ;;% g ' Imo'
SVSTEM
Vacuum Breaker
------(HC 121)
Pressure Test Kit
(HC-PTK)
.ised here to pressure
tact Oho -t-
Two Way Valve;
(HC -5205)
Three Way Valve
(HC -3344)
- NEW PLUMBING
EXISTING PLUMBING
Check Valve
(HC -1790)
FIG 12.1
,RETURN
FROM SOLAR
COLLECTOR
(WARM)
- ROOF SENSOR
VALVE CONTROLLER
4 POOLSENSOR
19
_-_- jr: _. ...
NOTE. CCI-LEC10115 SHALL NOT BE
INSTALLED IN 'CORDER ZONES' AS
51IOWD BY SHADED ARBA$ BELOW.
?T' -�
NELIOCOL COLLECT[
MAY BE LOCATED IN
ANY AREA EXCEPT
'CORDER ZONES"
NOTE, MEAN ROOF —
HEIGHT . 25'-0- MAX.
a =1
tw
i//�/iLE TRU55NDITIONHELIOCOL
COLLECTORS ////-��--�����\WIDTH OF CORNER ZONE
5H S. BE O PERCENT
OF SHORT DIMENSION OF
rJ - I BUILDING, OR 40
PERCENT OF MEAN ROCF
HEIGHT, OR T FEET,
WHICHEVER 15 SMALLER
I NOTES, HELIGL^OL COLLECTORV
RISER SYSTEM. HELIOCOL GATOR W Tj
GATOR CL MTP ANCHOR L THESE PLANS MEET THE 7004 FLORIDA BUILDING CODE. SECTION R30t7.11. FOR CLAMP W/ LAG
LAG BOLT A5 6HOUN BELOW BOLTS. /
SPACED • 7'-0" OC- TYP. WND EXPOSURE CATEGORY "C" THESE PLANS REM
PLAN AT COLLECTORS I
S-1
NATE MEAN ROOF
HEIGHT s 25'-0' MAIC
HELIOCOL 'GATOR HELIOCOL 'GATOR
CLAMP- 1-+ELIOCLIL CLQ.
I [0.R SYS
f RISER SYSTEM.
"'DOD TTd 1 5 NJ
7 SYP, OR BETTER
14" DIA STAINLE55 STEEL
LAG BOLT AT EACH
GATOR CLAMP
FLAT BUILT-UP ROOF
eC�LG Y- ..�
S -I
WOLCD TRU5Sk5 NO.
7 5YP, OR BETTER
'I.- DIA. STANLESS
LAG BOLT AT EACH
G4TOR CLAMP
THAT AN UPDATE I CT UNTIL FUTURE
CODE REV1910N5 DKTATE UPDATE IS NECES
j. COLLECTOR CCTAIECTIONS SHOWN HAVE BEEN DESIGNED TO RESIST WIND
LOADS OUTLINED W 7004 FLORIDA 50LDING
Tn4nrL 19vyM.tt b,/E
Ft. qua Nv m>9
€
MPH EXPOSURE "C' WIND VELOCITY, AND FOR ASCEE. CHAPTER 16• FOR
MIEN EXPOSURE 'C:' WMD �. CHAPTER 6.0. 140
14
WOOD ice` -/SES
.
VELOCITY, TYPICALLY
1 SYP. OR BETTER
R
3. LAG BOLT CAPACITIES AND EMBEDMENTS ARE BASED UPON "NATIONAL
DE51C3D SPECIFICATION FOR STRESS GRADE LUMBER
I"i" DIA. STAINLESS STEEL
LAG BOLT AT EACH
0
(_] u,
AND RAStFUDMGS' A5
PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION
¢ATOR CLAMP ^
�l
4. WEND TUNNEL TEST
�.waa
DATA FOR THESE CCNDECTIONS WAS BEEN C:O-PILED BY
TEXAS 4 t M UNIVERSITY, COLLEGE STATION, TEXAS,
HEL TOCOL
AND IS AVAILABLE
THROMW weLIOCOL. INC.
5. PROVIDE 'I"
STRAP ANCHOR -I
o UJ
DIAMETER LAG BOLT rHRCVGH CENTER HM OLE EACH GATOR
CLAMP - LEAVE TIO OUTERMOST HOLES
J
EMPTY, TYPICALLY.NOTE
S-
zao
MEAN25 ROOF NOTE: MEAN ROOF
WIGW
HEIGHT . i5'-0" MAX. HEIGHT . 75'-0" MAX.
Ih'.
NOTE. MEAN ROOF
HEIGHT
DRILL HDLE TI4RU
NELICKOL 'GATOR CONCRETE TILE AND
. 75'-0' MAX 2` IOYa LAG
a6" STAINLESS STEEL BOLT, TYP. EA. SUV
C+ V a
CLAMP' INSTALL LAG BOLT t0
AS NOT TO BREAK TILE.
ALL-iHRZE4p ;•-®" pO_ STAR COMIECTICN
WT =R
U
CONCRETE TILE PROVIDE 3" BOLT
�✓ t EA. END
PROVIDE 'LOCTITEAT
Z Ri gg�
Q' Q 6
HELIOCOL EMBEDMENT INTO WOOD
COLLECTOR TRU55 BELOW.
ALL WTS, TTP. H�ELI��OCOL "GATOR
F ¢
-RISER SYSTEM.
w
- HELIOCO-
WOOD TRUSSES NO. COLLECTOR
7 SYP. OR BEER TTRISER SYSTEM.
HELIOCOL
COLLECTOR
-
4s• 5 nAx ^
--RISER SYSrE
WOOD ITaissEs
Pe.n pT
14" DIA STAINLESS STEEL•
j'-0" O.C.
nr
LAG BOLT AT EACH 1N
GATOR CLAMP 45' MAX _
BARREL
BARREL
PRESSURE TREATED CONT, TILE
1
2.4 FOR GATOR CLAP i
MO.NTMG. TYP. AT TOP t BOT. 45' MAX
OF COLLECT
•
SLOPED CONCRETE DR PANEL TYP.
SLOPED 511INGLE ROOF 4 TILE ROOF g SLOPED BARREL
....
.�"`••..� S -I �.N•..� S -I TILE ROOF 6
Seminole County Property Appraiser Get Information by Parcel Number Pagel of 2
http://www.scpafl.org/web/re—web.seminole—county title?parcel=36193051l OJ000050&c... 6/25/2007
LJAVIDJOHtdIs 3k6;GFA,ASS;A
PROPERT.
. A��
sErntNo�..��csu ncry
t TQte`�4FIR57SI
s�aliFa�}7o.FL 33'71 -t 116$
407-g6S.,a45W
2007 WORKING VALUE SUMMARY
GENERAL
Value Method: Market
Parcel Id: 36-19-30-511-OJ00-0050
Number of Buildings: 1
Owner: KESSLER JULIE
Depreciated Bldg Value: $160,844
Mailing Address: 1903 S PALMETTO AVE
Depreciated EXFT Value: $3,896
City,State,ZipCode: SANFORD FL 32771
Land Value (Market): $44,955
Property Address: 1903 PALMETTO AVE SANFORD 32771
Land Value Ag: $0
Subdivision Name: GARNERS ADD TO MARKHAM PARK HEIGHTS
Just/Market Value: $209,695
Tax District: S1-SANFORD
Assessed Value (SOH): $91,014
Exemptions: 00 -HOMESTEAD (1994)
Exempt Value: $25,000
Dor: 01 -SINGLE FAMILY
Taxable Value: $66,014
Tax Estimator
SALES
2006 VALUE SUMMARY
Deed Date Book Page Amount Vac/Imp Qualified
Tax Amount(without SOH): $2,787
WARRANTY DEED 02/2007 06591 1831 $263,000 Improved Yes
2006 Tax Bill Amount: $1,256
FINAL JUDGEMENT 03/1998 03382 1560 $100 Improved No
Save Our Homes (SOH) Savings: $1,531
WARRANTY DEED 11/1983 01500 1357 $82,000 Improved Yes
2006 Taxable Value: $63,794
Find Comparable Sales within this Subdivision
DOES NOT INCLUDE NON -AD VALOREMASSESSMENTS
LAND
LEGAL DESCRIPTION
Land Assess Land Unit Land
Frontage Depth
PLATS. Pick
Method Units Price Value
LEG LOTS 5 + 7 + N 1/2 OF VACD ALLEY ON
FRONT FOOT & 111 118 450.00 $44,955
S BLK J N H GARNERS ADD TO
DEPTH .000
MARKHAM PARK HEIGHTS PB 1 PG 81
BUILDING INFORMATION
Bid Bid Type Year Bit Fixtures Base SF Gross SF Living SF Ext Wall Bid Value Est. Cost New
Num
1 SINGLE 1956 6 1,704 2,762 1,704 CONC $160,844 $195,555
FAMILY BLOCK
Appendage / Sgft OPEN PORCH FINISHED/ 24
Appendage / Sgft UTILITY FINISHED / 96
Appendage / Sgft GARAGE FINISHED/ 572
Appendage / Sgft OPEN PORCH FINISHED / 30
Appendage / Sgft DETACHED GARAGE UNFINISHED / 336
NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed
Porch Finished, Base Semi Finshed
Permits
EXTRA FEATURE
Description Year Bit Units EXFT Value Est. Cost New
ALUM SCREEN PORCH W/CONC FL 1979 440 $1,496 $3,740
SPA 1979 1 $1,000 $2,500
SAUNA/STEAM ROOM 1979 1 $1,400 $3,500
http://www.scpafl.org/web/re—web.seminole—county title?parcel=36193051l OJ000050&c... 6/25/2007
LIMITED POWER OF ATTORNEY
Date
I hereby name and appoint
of --,c. 1
to be my lawful attorney in
fact to act for me and apply to
for
a
permit for work to be performed
at a location described as: Section Township
Range_ 30 _ Lot Subdivision
a
11(
(Address of Job)
kvwner or rroperty and Address)
and to sign my name and do all things necessary to this appointment.
oignature or Uertitied Contractor
Acknowledged:
Sworn to and subscribed before me this
Day of A.D. 20 0 7
Notary Public, State of Florida
My Commission Expires:
r
Signatur
Jennifer McKinne
NOTARY PUBLIC -STATE OF FLORIDA
kvJennifer McKinney
Commission # DD549592
My Comm. Expires: 06/24/2010