Loading...
HomeMy WebLinkAbout2050 Spinner Ln (2)r- . --------'. CITY OF SANFORD PERMIT APPLICATION Application '# : V 9 ,� 4 Job AddresO�pinner Lane Sanford, FL 32773 Parcel ID: 03-21-31-5AY-0000-OOEO Zoning: Description of Work: Entrance Sign RECEIVED Submittal Date: Value of Work: $ 1,000 �� Historic District: Square Footage: N/ Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler/Alarm ❑ Pool ❑ Sign X Electrical: New Service — # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial X Industrial ❑ Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) ........................................................................................................................ Property Owner: Sanford Airport Authority/Orlando Sanford Airport Southeast Ramp Hangar Development, Inc. Address: 1200 Red Cleveland Blvd Sanford, FL 32733 Phone Bonding Company: NA Address: E-mail: Contractor: Winter Park Construction Address: 221 Cirle Drive Maitland, FL 32751 Phone: 407-644-8923 State License Number: CGC 019537 Mortgage Lender: NA Address: Architect/Engineer: Eric D. Kuritsky Architect Phone: 407-898-6654 Address: P.O. Box 561227 Orlando, FL 32856 Fax: 407-898-7992 Plan Review Contact Person: Paul Jenny, Jr. Phone: 407-644-8923_ Fax: 407-645-1972_ E-mail: paulj@wpc.com Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. ,IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions appy able t th s property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such s wayriiAnagement districts, state agencies, or federal agencies. Acceptance of e it is verification at I wil tify the owner of the property of the Si tureofOwner/ ent Date Print O gents e ! b Signa ure of Nota -State of Florida Date PHYLLIS I. GIBSON MY COMMISSION #DD477598 ,+��EXPIRES: OCT 02, 2009 Owner/Agent it , ersonalled t roo�nli�oglvhe onsurance Produced ID APPROVALS: ZONING: L1+ &5D_ 0-1 UTIL: FD: Special Conditions: Rev 02/2007 a �t f;z t 4``' c of 1714rida LierVLaw, FS 713. C SAle 7 Si atur of Co for/Agent Date �Rdv �'yr�7 ✓.2 . Print Contractor/Agent's Name --f 7 Signat e ofSt e fFlorida D to 61- ,0""' KAYSTY JANE JONES' KRESS * * MY COMMISSION I DD 201271 o�. EXPIRES: June 1, 2007 . B ed Thru Budget Notary Services Contractor/Agent is Personally Known to Me or Produced ID ENG: -3Z'-q Q "a cE su/_,-'), BLDG: 0 .____4 E fta c? ERIC D. KURITZKY ARCHITECT AR0007981 --- Southeast Ramp Hangars PERM9 # Entry Sign DATE' 7A� V4 i : -W I s j' I i i ....----_._ ._-.......... .... f fWELJ r- Cl" ORD • tom,, ERIC D. KURITZKY ARCHITECT `" 1 ... ...... ..... . - ............................................... t AR0007981 u, P yD es, Southeast Ramp Hangars + Entry Sign GENERAL CONDITIONS AND NOTES 1. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES. HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. ALL CONTRACTORS SHALL DO THEIR WORK IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES IN THE DRAWINGS AND EXISTING CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCING WORK. , 3. CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD IN THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS, AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK. 4. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ARCHITECT AND MAY NOT BE USED OR REPRODUCTED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 5. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. THE CONTRACTOR SHALL CONSULT THE ARCHITECT IF THERE IS ANY UNCERTAINTY REGARDING THE INTENT OR APPLICATION OF A DETAIL OR CONSTRUCTION ISSUE. 6. ALL DIMENSIONS AND ELEVATIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 7. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH AND MEETS THE REQUIREMENTS OF SECTION 1606, 2001 EDITION OF THE FLORIDA BUILDING CODE. IT IS DESIGNED TO WITHSTAND 120 MPH EXPOSURE B WIND LOADS. MINIMUM DESIGN PRESSURE FOR OPENINGS IS +25.9,-28.1 PSF. ALL CONNECTIONS HAVE BEEN CHECKED TO WITHSTAND ALL APPLICABLE LOADS. DESIGN WIND LOAD IS 120 MPH WITH SHAPE FACTORS. NET UPLIFT DESIGN PRESSURE SHALL BE 30 PSF. DESIGN ROOF LIVE LOAD IS 20 PSF 8. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION. 9. CONTRACTOR TO OBTAIN ALL PERMITS, AND PAY ALL FEES AND TAXES. FOUNDATIONS 1. FOUNDATION DESIGN IS BASED ON AN ASSUMED ALLOWABLE BEARING PRESSURE OF 2000 PSF AND SHALL BE VERIFIED BY A GEOTECHNICAL ENGINEER REGISTRERED IN THE STATE OF FLORIDA. 2. ALL REQUIREMENTS FOR SITE PREPARATION AND SOIL COMPACTION SPECIFIED IN THE SOILS REPORT SHALL BE FOLLOWED UNLESS ADDITIONAL MORE STRINGENT REQUIREMENTS ARE SPECIFIED. NOTIFY ARCHITECT IF FOUNDATION CONDITIONS ENCOUNTERED DIFFER FROM SOILS EXPLORATION INFORMATION MADE AVAILABLE TO THE CONTRACTOR. 3. SOIL SHALL BE COMPACTED TO A MINIMUM OF 95% OF MAXIMUM MODIFIED PROCTOR DENSITY. CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON GRADE AND FOOTINGS 2500 PSI 2. ALL CONCRETE SHALL HAVE A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4%'AIR .ENTRAINMENTS, AND A MAXIMUM WATER(CEMENT RATIO OF 0.58. 3. CONCRETE MIX DESIGN SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ACI 301 CHAPTER 3, METHOD 1 OR METHOD 2. SUBMIT BACKUP DATA AS REQUIRED BY CHAPTER 5 SECTION 5.3 OF THE LATEST EDITION OF ACI 318 4. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60. 5. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301. ...................................._......... ......... .... ........... ........ ....... P.O. BOX 561227 ORLANDO, FLORIDA 32856 (407) 898-6654 (407.. 898-7992 FAX