Loading...
HomeMy WebLinkAbout401 W 20 StCITY OF SANFORD PERMIT APPLICATION .Application N: - � � + Submittal Date: Y}� Value of Work: $ .Job Address: `Q Tt1: �( cI 3L) .��L� <3lW - c:: -A Zoning: Historic District: P9rrP1 �'' A ` f W rk• \%A W i 'S Square Footage: Description o o Permit Type: Building* Electrical ❑ Mechanical 13 Plumbing E3 Fire Sprinkler/Alarm 13 Pole E3 Sign E3 Electrical: New Service — # of AMPS Addition/Alteration Change of Service 13 Temporary Pole 13 sidential El Replacement [3 New ❑ (Duct Layout & Energy Calc: Required) Mechanical: Residential ❑ Non-Re Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing Repair Residential ❑ Commercial Plumbing/New Residential: # of Water Closets — D Commercial ❑ Industrial ❑ Occupancy Use Group(s): 5F Occupancy Type: Residential NF 1FEMA form required) # Construction Type: �_ of Stories: I. # of Dwelling Units: Flood Zone: .►... ........ ..... .........................................•.................... ..........1�a_ ,�............... �r 1a, µ: k4kG Contractor: Property owner: � � � Address: Address:?714 eltsmentP�%I c 133 1 Lic -1t v Phone 7224A[--o-01-0�E-mail:Phoney State License Number ` Mortgage Lender: Bonding Company: ?; >�!- Address: Address: Phone: Architect/Engineer: Fax: Address: M Phone -7�'I Ll(X.� Fax: 3 $j_l L10"a. E-mail• Plan Review Contact Person: -� k or install ti as e ri Application is hereby made to obtain a permit it toormee sand tandards of all laws regulating construction nnstahations as- i' .1ditated. I certify that no rth s juri dict on. I understand that a separate issuance of a permit and that all work will performed permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS., and AIR CONDITIONERS, etc. work l be one in OWNER'S AFFIDAVIT`. WARNING TO OWNERforegoing YOUR FAII-URE TO RECORD A NOTICE OFICO dMMENCE compliance MAY RESULT IN YOUR PAYING AN construction and caning. TWICE FOR IMPROVEIv1ENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there maybe additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. ��� Acceptance of it is verificatio th I it notify the owner of the property of the requirements of Florida Lien Law, F� .3). o Date g" r ent Signature of ContractorlAgen, Print Owner/Agent's Name n 9 n Si o o ary-State o Florida® Date Notary Public State of Florida ,lennffer Burke Aly Commission DD543347 or a° Expires 05/27/2010 Owner/ ent is Personally Known to Me or oducedID APPROVALS: ZONING: UTIL: FD; Special Condifio Rev 02/2007 Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID _ ENG: BLDG:. W7,* 7 CAr , S. a6 t POWER Or ATTORNEY Date: %ZI U /C,)::7 I hereby name and appoint Zmo kP To be my lawful attorney in fact to act for me and apply to the Sr& -IC r - Building Department for a .,— - n, 1 permit for work to be performed at a Location described as: Section , Township , Range , Lot . , Block Subdivision �(� 1 �(% �% 2t (address of job) M.C-- -LPar = owner of property and and sign my name and do all things necessary to this appointment L4 VI �IoC CFype or print and signature name of Certified Contrac The foregoing instrument was acknowledge before me this' By I J(A I A rJ-, Who is onall know e/who produced As identification and who did not take oath. State of Florida, County of Commission lr`J/ Ory) My Commission Expires: U)IL) 1/00 00 o Notary Public State of Florida a4 Jennifer Burke My Commission DD543347 '?a n° Expires 05127/2010 Permit Number- `' Parcel Identification Number3l�A"l 30•53y-VIw Uf-c Prepared by: �re(\DL Window World Inc. Return to: 624 Douglas. Ave. Ste. 1412 Altamonte Springs, FI 32714 NOTICE OF COMMENCEMENT State of County of I IN li Ili fl It 11111131111111 if ii ff ii! ii !!i ii g! IN 13 iii 111iii MARYANNE MIiRSE, CLERK OF CIRCUIT COURT Sf MINOLE COUNTY SK 06758 Rg 191761 Qpg) CLERK' D e E�00710219- ,,5 REWRDED 07/161,0007 09120:11 AN RECORDINS FEES 10.otT REWRDED BY T Smith CERTIFIED COPY IAARY A"':F MORSE �,�ERK OF CIRCUIT COURT SEMINO�E"7 LINTY F R RY Y CLERK The undersigned hereby gives notice that improvement(s) will be made to certain real property, and in accordanc4 w 400 Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. V 1. Description of property (legal description of the property, and street address if available) 1 fa+S Vv •-V t ► (3Lk l 1k-� 2. General e`sprip ion of improvements 3. Owner information Name fy\;. Com\ YV1; \t \c� y\a, Telephone Number Address rte` Fax Number Interest in Property: 4. Fee Simple Title Holder (if other than owner shows above) Name Telephone Number Address Fax Number 5. Contractor Name Address 0 Window World Inc. 624 Douglas Ave. Ste. 1412 Altamonte Springs, FI 32714 Surety (if any) Name �� Address n 7. Lender (if any Name NIA— Telephone Address Number Fax Number Telephone Number Fax Number Amount of bond $ _ Telephone Number Fax Number 8. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by 713,13(1)(a)7, Florida Statutes. Name Telephone Number Address PA- Fax Number 9. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in 713.13(1.)(b), Florida Statutes. Name/,/.- Telephone Number Address A/,Fax Number 10. Expiration date of notice of commencement (if expiration date is one year from the date of recording unless different date is specified): �„ ray Date Signed ' nature of Owner (Note: per 713.13(1)(g), "owner must sign ... and no one else may be permitted to sign in his or her stead." Sworn to and subscribed before me this ay of �- J� 20 6--� by Lc ,L,\,Jj '`- r who is personally known to me OR — produced as identification. e Y Poo Notary Public State of Florida i� Jennifer Burke y, My Commission DD543347 `'�a 6ws 0512712010 Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 http://www. scpafl. org/web/re_web. seminole_County_title?parcel=3 6193 05 3401000100... 6/27/2007 DAVID JOHHsoN. CFA, ASA I I m 143.4 152.0 -154.4 149,4 -147.4'x- PROPERTY < W 20TH ST APPRAISER i a ,, ., a SEMINOLE COUNTY FL. 1101E. 4.0 — 5.0-8A�-10.0 1.4 _ 2.4 s; ak FIRST 5T :}{ \ SAN FORD, FL32771-1468 1.0 35A - ,.a 33.4 - 407 - 665-7506 a 12.0 7.4 � 2007 WORKING VALUE SUMMARY GENERAL Value Method: Market Parcel I d : 36-19-30-534-0100-0100 Number of Buildings: 1 Owner: MIKKOLA MICHEL K TRUSTEE Depreciated Bldg Value: $86,180 Own/Addy: FBO MICHEL K MIKKOLA Depreciated EXFT Value: $600 Mailing Address: 401 W 20TH ST Land Value (Market): $46,125 City,State,ZipCode: SANFORD FL 32771 Land Value Ag: $0 Property Address: 401 20TH ST W SANFORD 32771 Just/Market Value: $132,905 Subdivision Name: HIGHLAND PARK Assessed Value (SOH): $132,905 Tax District: S1-SANFORD Exempt Value: $25,000 Exemptions: 00 -HOMESTEAD (2007) Taxable Value: $107,905 Dor: 01 -SINGLE FAMILY Tax Estimator SALES Deed Date Book Page Amount Vac/Imp Qualified 2006 VALUE SUMMARY QUIT CLAIM DEED 01/2006 06168 0686 $64,500 Improved No 2006 Tax Bill Amount: $2,477 PROBATE 01/2006 06095 0162 $100 Improved No 2006 Taxable Value: $125,834 RECORDS DOES NOT INCLUDE NON -AD VALOREM WARRANTY DEED 06/2005 05772 0817 $100 Improved No ASSESSMENTS Find Comparable Sales within this Subdivision LAND Land Assess Frontage Depth Land Unit Land LEGAL DESCRIPTION Method Units Price Value PLATS: Pick... FRONT FOOT & 50 100 .000 450.00 $18,450 DEPTH LEG LOTS 10 + 11 BLK 1 HIGHLAND PARK FRONT FOOT & PB 4 PG 28 DEPTH 75 100 .000 450.00 $27,675 BUILDING INFORMATION Bid Year Base Gross Living Est. Cost Bid Type Fixtures Ext Wall Bid Value Num Bit SF SF SF New 1 SINGLE 1946 3 1,123 2,198 1,376 CB/STUCCO $86,180 $153,208 FAMILY FINISH Appendage / Sgft ENCLOSED PORCH FINISHED / 253 Appendage / Sgft ENCLOSED PORCH UNFINISHED / 270 Appendage / Sgft GARAGE UNFINISHED / 552 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished, Base Semi Finshed EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New FIREPLACE 1946 1 $600 $1,500 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. "" If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www. scpafl. org/web/re_web. seminole_County_title?parcel=3 6193 05 3401000100... 6/27/2007 of Central Florida, Inc. "Simply the Best for Less" 624 Douglas Avenue, Suite 1412 - Altamonte Springs, FL 32714 (407) 389-1400 - Fax (407) 389-1402 Name: d2ilILLl6e4L/6C1#7 Phone (H): % 0 ,-+— Phone (W): Install Address 4 l Phone (other): City, State, Zip:, 71 DOUBLE HUNG Series 4000 DH Insulated 101 U1 $200 Q O SLIDER -CASEMENT 2 Lite Slider Insulated $369 Series 4000 DH Insulated 101 UI + $223 3 Lite Slider Insulated $549 Series 4000i DH Insulated $244 Casement Insulated $339 Half Screens $15 Colonial Grids $52 f PPG Solorban 60 Low -E Glass/Argon $52 0 Full Screens $29 Double Locks (on windows >25") $5 /, ��L PPG Solarban 60 Low -E Glass $32 ry _Argon Gas $15 Lifetime Glass Breakage Warranty $11 Foam Insulation on Jambs $11 d1G Colonial Grids $32 Almond Color Contoured Grids $37 Half Screens $15 Almond Color $45 Full Screens $29 Tint Gray/Bronze $30 Tint Gray/Bronze $30 Wood Grain, Interior (4000 or 6000) $90 Oriel / Cottage Style (40/60 or 60/40) $45 PATIO DOORS & FIXED GLASS -(Fixed Glass) Insulated$3&(e_ _LI -Lifetime Glass Breakage Warranty $11 oY±-J- C IMPACT Speciality Window Series 3100 SH $ Low -E Patio Door/Argon. Gas $125 Series 3102 2 Lite Slider $ Vinyl Sliding Patio Door 5'x6'8" $750 Series 3104 Fixed Glass $ Vinyl Sliding Patio Door 6'x6'8" $875 Series 51I Sliding Patio Door Ft. $ Vinyl Sliding Patio Door 8'x6'8" $975 Vinyl Sliding Patio Door 9'x6'8" $1075 Screen Patio Door $58 MISCELLANEOUS Grids Patio Door $100 Remove) &Install $100 Custom Exterior Cap & Wrap $50 Aluminum Window Removal $60 Mull to Form Multi -unit $55 /! Custom Exterior Trim $75 Tempered DH Sash (BSO) (TSO) $35 Tempered Other $8/Sq. Ft. You the buyer are responsible for the removal Obscured Glass $30 and installation of any existing security system, Tint Gray or Bronze $45 burglar bars,drapes, blinds, A/C . Initial: You the buyer may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. Notice of cancellation must be in writing postmarked no later than midnight of the following third business day. THIS IS A CUSTOM ORDER Please see reverse side for additional terms & conditions. Customer Agrees to the terms of Payment as follows: Extra Labor $ Landfill Disposal Fee $50 $ $50.00 Permit & Fees $ 1/_s0 00 Total Amount $ ggqt_/-`1-0 41 Custom Order Deposit 50% $ Balance Paid to Installer upon Completion $ >7. y 7d Buyer agrees that he has read and understands all terms and conditions on front and back of this contract and agrees to each and every term and condition. Salesman Date ` "6 //RwV r Date White Copy - Original Yellow Copy - Customer WINDOW MEASUREMENTS NAME: IV - r — # OF STORIES:_ MEASURED BY: _ DATE: TYPE OF CONSTRUCTION: J,7l -nr_,4 TYPE OF WINDOWS: ' # OF WINDOWS: SIZE (wxh) mmmmmm MEMNON -MENN■N m, ®ERNME He m MEMEMIM No MEN . SEE No■ P.A.MMEEMIN �F�1-MM■M■M . • . ®EENIME .. M MEMO MwEEMMEMI �-MEME■IM �MENEM -EMEMEN 11MIMEM 00 ME MEMO -■MME■N D rawi n Screwed in: Stucco: Brick: Other: k.9 tn A 0 gd r*orn s tjc;h, s Tzvp 0&r,A' f Ali OFFICE tivi LG/ LVVI - 14. V1 --- -r--- Architectural Testing July 11, 2006 Marsh Fernbaugh, Director of Testing Associated Materials, Incorporated 3773 State Road Cuyahoga Falls, Ohio 44309-1365 RE: Masonry Installation of 0201 Double Hung Windows sizes 4' 0" wide by 6'6" tall and 3'0" wide by 6'0" tall. Dear Mr. Fernbaugh: I have performed an installation fastener analysis for your 0201 Double Hung Window installed to masonry walls. The windows considered were as follows: S $Ze _ W- Test Renort No, 4'0" x 6'6" 30 psf 62509.02-50147 3'0" x 6'0" 50 psf 62509.02-50147 My analysis assumed using 3/16" diameter Tapcon anchors with a minimum embedment of 1-1/4". To safely resist the design wind pressure, 7 such anchors are required. At installation, use three (3) anchors in each jamb: one near the top and bottom corners and one (1) at mid span. And, one (1) anchor in the mid span of the head. If you have any questions regarding my analysis, please contact me. Sincerely, ARCHITECTURAL TESTING, INC a"r,611 4. oe-eA.R- eaww.+4rc+h -ft" Joseph A. Reed, P.E. Director -- Engineering Services JARJar cc: 65030.02-122-34 130 Derry Court York, PA 17406.6405 phone: 717.764.7700 fax: 717.7644129 www.archtest.com TAPCON DCIMATE LOCATIONS WINDOW JAMB 3/16' TAPCON ANCHOR MBC" 1-1/4' PENETRATION INTO MASONRY FRAMING (TYPJ dMI.2_ONTAL. _ SECTION NOTESr 1. INSTALL (3> 3/16' DIA. TAPCONS PER JAMB, 3' FROH EACH CORNER AND MID SPAN ABOVE MEETING RAIL. AND, (1) IN THE MIO SPAN OF THE HEAD (7 TOTAL). 2 SELECT SCREW LENGTH SUCH THAT A MINIMUM PENETRATION OF 1-1/4' IS ACHIEVED INTO THE MASONRY FRAMING. a INSTALL TAPCON ANCHORS ACCORDING TO TAPC13N INSTALLATION INSTRUCTIONS 4. SEAL INTERIM AND EXTERIOR PERIMETERS WITH SILICONE CAULKING 5. MASONRY FRAHM SHOULD BE CONCRETE, MASONRY BLOCK, OR LIGHTWEIGHT MASONRY BLOCK. 6, ATI TEST REPORT 6MO.W-501-47 MODEL 02M DESIGN WMD LOAD MPJ VMD 4'-0' X 6'-6' 30.0 psf 3'-0' X 6'-0' 50.0 psf 3/4' SHIM 041X) FRAMING Joseph A. Reed 130 Derry Court York, PA 17406 FL PE 058920 yl- 7 • ~ FR JECT PIM.M ' 0201 DOUBLE HUNG V DVCr�X 1 O1-65030.02 MASONRY INSTALLATION DRAWING 122-34 mmw- ASSOCIATED MATERIALS, INCORPORATED _ _ _,� 6!16/06 I Florida Building Code Online User: Public User - Not Associated with Organization - Application #: Date Submitted: Code Version: Product Manufacturer: Address/Phone/email: ar,%, i. w, Need _Hel FL1089-R1 06/14/2005 2004 Alside, Inc., Division of AMI 3773 State Road Cuyahoga Falls, OH 44223 (330) 922-2108 Technical Representative: Marsh Fembaugh Technical Representative Address/Phone/email: 3773 State Road Cuyahoga Falls, OH 44281 mfembaugh@alside.com Category: Windows Subcategory: Double Hung Evaluation Method: Certification Mark or Listing Referenced Standards from the Florida Building Section Standard Year Code: ANSI/AAMA/NWDA 1997. 1011S-2 Certification Agency: Quality Assurance Entity: Validation Entity: Authorized Signature: American Architectural Manufacturers Association Marsh Fernbaugh mfembaugh@alside.com Evaluation/Test Reports Uploaded: Installation Documents Uploaded: http://www.floridabuilding.org/pr/pr_detl.asp?IPT=1089&RV=1 &fm=ROSrch 12/12/2005 M. - ^k . - Y� ges . a 4 O o . i , „ _ t. 3 K Need _Hel FL1089-R1 06/14/2005 2004 Alside, Inc., Division of AMI 3773 State Road Cuyahoga Falls, OH 44223 (330) 922-2108 Technical Representative: Marsh Fembaugh Technical Representative Address/Phone/email: 3773 State Road Cuyahoga Falls, OH 44281 mfembaugh@alside.com Category: Windows Subcategory: Double Hung Evaluation Method: Certification Mark or Listing Referenced Standards from the Florida Building Section Standard Year Code: ANSI/AAMA/NWDA 1997. 1011S-2 Certification Agency: Quality Assurance Entity: Validation Entity: Authorized Signature: American Architectural Manufacturers Association Marsh Fernbaugh mfembaugh@alside.com Evaluation/Test Reports Uploaded: Installation Documents Uploaded: http://www.floridabuilding.org/pr/pr_detl.asp?IPT=1089&RV=1 &fm=ROSrch 12/12/2005 rage L ui Florida Building Code Online Product Approval Method: Method 1 Option A Approved Application Status: 08/05/2005 Date Validated: 08/24/2005 Date Approved: Date Certified to the 2004 Code: http://www.floridabuilding.org/pr/pr detl.asp?IPT=108,9&RV=1&fin=ROSrch 12/12/2005 Page 1 11 Page: Go Product Modet # or Model Limits of Use pp/Seq # Name Descri tion Replacement: " 0201:48x pP30, 44x77 8x78 DP30, 4x77 DP35, annealed) (118 annealed) DP35, 1089.1 0201 x60 DP45, 36x72 DP55; 118" 4x60 (1/8" annealed) annealed45, xDP572 8 lass 5 New 0301:48x77 (3/32" Construction: annealed) DP25, 44x77 8x77 DP25, 4x77 DP30, (3/32" annealed) DP30, annealed) 1089.2 0301 4460 DP35, 4x60 (3/32" P35, 36x72 32 36x72.DP50; 3132" �nnealed) DP50 lass Replacement: 0401:48x78 DP25 (1/8" 8x78 DP25, annealed), 44x77 (1/8" 4x77 DP30, annealed) DP301 44x60 1089.3 0401 44x6o DP40, (1/8" annealed)DP40, 36x72 (1/8" annealed) 36x72 DP35; 118" lass DP35 Replacement: 0501:52x84 (1/8 52x84 DP25,annealed). DP25, 44x77 4x77 DP40, (1/8 annealed) 1040, x60 DP45, x60 (1/8" annealed) 1089.4 0501 36x72 DP45, DP45, 36x72 (1/8" 36x60 DP60; 1/8" annealed) DP45, 36x60 lass 1/8" annealed DP60 Replacement: 52x61 DP35; 1/8" 0501:52x61 "C" packac 1089.5 0501 lass,3 cam (1/8" annealed) DP35 locks/keepers, DP ilt.latch wP'H Key" Replacement: 4x77 DP30, 8001:44x77 DP30,44x( 1089.6 8001 x60 DP40, 36x72 DP40; 3/32' DP40.36x72 DP40. lass Replacement: x77 DP35, 9001:4477 OP35,441 4x60 DP50, Dp50,36x72 DP50,36xi 1089.7 9001 36x72 DP50, DP65 3.6x60 DP65; 3/32" lass Next http://www.floridabuilding.org/pr/pr detl.asp?IPT=108,9&RV=1&fin=ROSrch 12/12/2005 i Ak Architectural Testing Marsh Fernbaugh, Director of Testing Alside Window Company 'amu 3773 State Road Cuyahoga Falls, Ohio 44309-1365 March 30, 2003 r' RE: Masonry Installation of 0970 Fixed Windw size 6'0"wide by 4'0" tall. Dear Mr. Fernbaugh: I have performed an installation fastener analysis for your 0970 Fixed Window installed to masonry block walls. The window size considered was a 610"wide by 4'0" tall (DP = 40 PSF). The design wind pressure for this window was determined by the testing documented in ATI Test Report 05-30442.01. My analysis assumed using 3/16" diameter Tapcon anchors with a minimum embedment of 1-1/4". To safely resist'the design wind pressure, 7 such anchors are requir ed. At installation, use two anchors in each jamb: one near the top and bottom corners, and three anchors in the head: one near each comer and one at the mid span. This installation.detail is appropriate for smaller windows of this model subjected to the same design wind pressure. If you have any questions regarding my analysis, e contact me. Sincerely, ARCHITECTURAL TESTING, IN C V190 AD o h A. ed, P.E. irector — Engineering Services JAR -jar cc: 05-30442.01 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com Florida Building Code Online r -I"' _. -9r 'Ir .I Overview Product Search Organization Product User: Public User - Not Associated with Organization - Need_Helh_? Application #: FL4738 Date Submitted: 06/17/2005 Code Version: 2004 Product Manufacturer: Alside, Inc., Division of AMI Address/Phone/email: 3773 State Road Cuyahoga Falls, OH 44223 (330) 922-2108 Technical Representative: Marsh Fernbaugh Technical Representative Address/Phone/email: 3773 State Road Cuyahoga Falls, OH 44281 mfembaugh@alside.com Category: WmdowS Subcategory: Fixed Evaluation Method: Certification Mark or Listing Referenced Standards from the Florida Building Section Standard Year Code: ANSI/AAMA/NWDA 1997 1011S-2 Certification Agency: American Architectural Manufacturers Association Quality Assurance Entity: Validation Entity: Authorized Signature: Marsh Fernbaugh mfembaugh@alside.com Evaluation/Test Reports Uploaded: Installation Documents Uploaded: http://www.floridabuilding. org/pr/pr_detl.asp?IPT=473 8&RV=O&fin=ROSrch 11/7/2005 F— .. .. _ Florida Building Code Online Product Approval Method: Application Status: Date Validated: Date Approved: Date Certified to the 2004 Code: Page: Go Method 1 Option A Approved 08/05/2005 08/24/2005 Pagel/1 ra�,vI-v.L/- pp/Seq Product Model # or Model Limits of Use # Name Description •�aaxeur.ma fl Copyrht and New VERifY� Construction: 0104: 72x36 (1/8" 738.1 0104 72x36 DP50,annealed) DP50, 48x24 8x24 DP65; 1/8" (1/8" annealed) DP65 lass Replacement: 0204: 72x84 (5/32" 738.2 0204 72x84 DP30; annealed) DP30 5/32 lass Replacement, 0704: 72x36 (1/8" 738.3 0704 2x36 DP50, 8x24 131365,11/8" annealed) DP50, 48x24 (1/8" annealed) DP65 lass Replacement: 0970: 96x60 (5/32" 96x60 DP40,annealed) DP40, 72x84 738.4 097015/32" 2x84 DP40, (5/32" annealed) DP40, 0x72 DP50; 0x72 (5/32" annealed) lass DP50 Next 4 d L .[^ `�P'."C�tfz`Y'4^✓ ��ICa.: �Y u.wnS...c�.t1.`w�S...d:•dw.ti,3w..w.a me"�L.</:Yat...�.i�... ..talsL.v^'i.7 'fir w..,t. .,-" S.uJi .�...sc"`K:4^- .Vec•1�31•gn;•fry._. Disclaime_r_; 02000 The State of Florida. All rights reserved. •�aaxeur.ma fl Copyrht and VERifY� http://www.floridabuilding.org/pr/pr_detl.asp?IPT=4738&RV=O&f n=ROSrch 11/7/2005