HomeMy WebLinkAbout2201 WP Ball Blvd (2)Permit # - U ' Job Address: Z—Zo It Description of Work: T i"21T 7, Historic District: Zoning: CITY OF SANFORD PERMIT APPLICATION Value of Work: Date: Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm V11 Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: Owners Name & Address: d (Z iLr.7C�C �9 Sir, i E d5 W \.- (Attach Proof of Ownership & Leg I Descripflon) . U 7 Phone: Contractor Name & Ad ress: Ii'V. v S cense Numbe : 03 3 /r ( U o%D 13 Phone F><z: /t l (J G r C tat Pe so Phone: K7 — (n ST, Bonding ompany- Address: Mortgage Lender: n Address: I C) L ; Architect/Engineer: Phone: Address: o Fax: Application is hereby made to obtain a permit to do the 6lvork�and ins 1 t�ottm as ndica I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standar sof all laws regulating construction in this jurisdiction. I understand fhat a f eparate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT FN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be f nd in the public records of this county, and there may be additional permits required from other governmental entities such as wa management districts, sta agencies, or Weral agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements bf 6f(wda Lie s�/� _ Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is _ Personally Known to Me or _ Produced ID btgnature /Lontractor/Agent I/ v Date Print ontrtractor/Agents Name ign re of Notary -State of Florida Date Contractor/Agent is ! Personally Known to Me -or APPLICATION APPROVED BY: Bld(02_<S _07 Zoning: Utilities: (Initial & Date) (Initial & Date) Special Conditions: (Initial & Date) FD: ([mhal &Date) o� LINDA L. PHILLIPS �S Notary Public, State of Florida My comm. exp. Sept. 29, 2006 Comm. No. DD 154192 CITY OF SANFORD FIRE DEPARTMENT / J FEES FOR SERVICES HONE # 407-302-1091 * FAX #: 407-330-5677 DATE: PERMIT BUSINESS NAME / PR JECT: ADDRESS: 2�? OI u--) . li E3A i I R)u� PHONE NO.: VAX NO.0 yo 7 / C-�S�G_ 97 CONST. INSP. [ J C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW F. A. [ ] F.S. �" HOOD [ ] PAINT BOOTH [ ] BURN PERMIT [ ] TENT PERMIT 1, ] � TANK PERMIT [ ] OTHER [\t_fQ ��J►� 1 � � — TOTAL FEES: $ G - Cx:�' (PER UNIT SEE BELOW) COMMENTS: Address / Bldg. # / Unit # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanford Fire -eve tion Division - Applicant's Signature Y . _ _ Fire Protection by Computer Design EAGLE FIRE PROTECTION 1205 CROWN PARK CIRCLE WINTER GARDEN FL. 34787 407-656-8387 Job Name PETCO Building NEW Location THE MARKET PLACE@ SEMINOLE TOWN CENTER System 1 Contract 04-55 Data File 04-55.WX1 JAMES M. CURTIS. P.E. 8801 Hunters Lake Drive Suite # 221 Tampa, FL 33647 Certificate # 37912 OCT 2 FLAKS REVIEWED CITY OF SANFOR® Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 J EAGLE FIRE PROTECTION Page 1 PETCO Date - Hydraulic Design Information Sheet Name - PETCO Date - 9/28/04 Location - THE MARKET PLACE@ SEMINOLE TOWN CENTER 1 1 Building - NEW System No. - 1 l Contractor - YOUNG CONTRACTING Contract No. - 04-55 Calculated By - E. MILLER JR. Drawing No. - 1 Construction: ( ) Combustible (X ) Non-Combustibl.e Ceiling Height - EXPOSED Occupancy - MERCANTILE S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .2 (X) Wet Make VIKING D Area Per Sprinkler - 116.67 ( ) Dry Model M E Elevation at Highest Outlet - 201811 ( ) Deluge Size 3/4 S Hose Allowance - Inside - 100 ( ) Preaction K -Factor 8.0 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 150 N Note Calculation Flow Required - 445.04 Press Required - Summary C -Factor Used: 120 Overhead 25.117 At BOR 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - JAN. 2004 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 52 @ Press - R Residual Press - 45 Elev. - Well Flow - 2040 Proof Flow S Elevation - 2 U —PLAN---- LANPP Location - SEE SITE P L Source of Information - TAKEN BY CITY OF SANFORD Y C Commodity Class 0 Storage Ht_ Area M Storage Method: Solid Piled o M { ) Single Row ( ) Conven. Pallet S R ( ) Double Row ( ) Slave Pallet T A ( } Mult. Row 0 C R K Flue Spacing A Longitudinal G E Horizontal Barriers Provide Location Aisle W. Palletized o ( ) Auto. Storage ( ) Solid Shelf ( ) Open Shelf Rack ( ) Encap. ( ) Non Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) EAGLE FIRE PROTECTION PETCO Page Date City Water Supply: C1 - Static Pressure 52 PSI C2 - Residual Pressure: 45 PSI C2 - Residual Flow 2040 GPM 150 140 130 P 120 R 110 100 D1 - Elevation 8.085 PSI D2 - System Flow 595.04 GPM D2 - System Pressure 35.763 PSI Hose (Adj City) GPM Hose ( Demand) 100 GPM D3 - System Demand 695.04 GPM Safety Margin 15.282 PSI E 90 S 80 S 70 U 60 R 50 C1 E 40 30 ------------- 20 3 10 D1 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (N^1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram ` EAGLE FIRE PROTECTION Page 3 PETCO Date 1 <- 13.78 2 1 13.78 3 --> 61.78 1 Q Q --> 40.40 101 - 19.18 102 - 2.03 103 i- 23.23 104 - 44.5110 5 <- 66.27 106 88.99 4 T 48.00 5 -> 53.56 107 - 31.34 108 --> 9.24 1 0 9 <- 12.85 110 F 34.96 111 - 57.35 112 t- 80.51 6 T 101.56 T 183.27 7 - 55.96 114 - 33.51 115 - 11.18 116 F 11.14 117 F 33.47 118 F 56.07 119 F 79.36 8 T 157.53 9 -i 8.50 120 <- 16.38 10 T 166.02 11 - 10.70 12 1 155.32 T 289.71 13 E- 920 14 T 146.13 T 298.91 15 - 973 16 T 136.40 T 308.64 17 - 12.12 18 T 124.28 T 320.76 19 - 12.20 20 T 112118 T 332.96 21 - 20.10 22 T 91.98 T 353.06 23 - 24.85 24 T 67.1_' T 377.91 25 <- 30.36 26 T 36.76 T 408.27 27 - 36.76 28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram 1 - 13.78 3 48.1111 rj - 101.56'7 e- 157.53 9 166.02 11 a- 155.32 13 - 146.13 155 F 136.40 17 i- 124.28 19 - 112.08 21 - 91.98 23 T 13.78 T 10.70 T 9.20 T 9.73 T 12.12 I 12.20 T 20.10 T 24.85 2 e- 13.78 4 t- 102.77 6 <- 183.27 8 a- 262.63 10 <- 279.01 12 t- 289.71 14 t- 298.91 16 - 308.64 18 t- 320.76 20 r- 332.96 22 F- 353.06 24 Ul 247.54 U4 - 247.54 U3 .- 545.04 BK - 545.04 TEST W Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram ` EAGLE FIRE PROTECTION Page 4 PETCO Date 23 67.12 25 +-- 36.76 27 T 24.85 T 30.36 T 36.76 24 - 37791 26 .- 408.27 28 - 445.04 TOR 1- 445.04 BOR � 545.04 U1 <-- 297.50 U2 t- 297.50 U3 a Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary EAGLE FIRE PROTECTION PETCO Fitting Legend Abbrev, Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow O PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 5 Date Fittings Summary EAGLE FIRE PROTECTION Page 6 PETCO Date Unadjusted Fittings Table 1 1/2 2 1/2 3/4 1 A B 21.5 9.0 17.0 C 1.0 1.0 1.0 D 12.0 1.0 E 2.0 2.0 2.0 F 1.0 1.0 1.0 G 9.5 17.0 D H 3.0 4.0 1.0 1 J 7.0 8.0 2.0 4.5 K 2.0 2.0 3.0 L 1.0 1.0 2.0 M 1.0 2.0 2.0 N 7.0 7.0 7.0 O 3.0 3.0 5.0 P 1.0 1.0 1.0 Q 5.0 8.0 7.0 R 1.0 1.0 1.0 s 4.0 5.0 5.0 T 3.0 4.0 5.0 U 14.0 2.0 2.0 V 4.0 5.0 5.0 W 3.0 3.0 4.0 X 6.0 6.0 8.0 Y 2.0 4.0 5.0 Z 2.0 2.0 2.0 1 1/4 1 1/2 2 21/2 3 31/2 4 7.7 21.5 9.0 17.0 12.0 19.0 21.0 7.0 10.0 12.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 9.5 17.0 D 28.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 27.0 35.0 1.0 1.0 1.0 1.0 2.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 3.0 4.0 3.5 6.0 5.0 8.0 7.0 6.0 8.0 8.5 10.8 13.0 17.0 16.0 H 4.5 5.0 6.5 14.0 10.0 14.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 8.0 9.0 11.0 12.0 13.0 41.0 50.0 6.0 8.0 10.0 12.0 15.0 K 2.0 2.0 2.0 3.0 4.0 18.0 8.0 29.0 13.0 35.0 1.0 1.0 1.0 2.0 2.0 40.0 M 7.0 9.0 11.0 14.0 16.0 19.0 22.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 1.8 2.2 2.6 3.4 O 3.5 4.3 5.0 6.8 P 10.3 8.5 10.8 13.0 16.0 3.0 8.0 10.5 12.5 15.5 22.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 F 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 H 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 1 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 K 36.0 55.0 45.0 L 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N O P Q 33.0 R S 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 U 4.2 5.0 5.0 V 8.5 10.0 13.0 W 13.1 31.8 35.8 27.4 X 21.0 25.0 33.0 Y Z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD EAGLE FIRE PROTECTION Page 7 PETCO Date Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 1 20.667 9.35 na 3 20.667 9.34 na 100 20.667 8 7.14 na 21.38 .2 78 7.0 101 20.667 8 7.04 na 21.22 .2 78 7.0 102 20.667 8 7.02 na 21.2 .2 78 7.0 103 20.667 8 7.03 na 21.2 .2 100.75 7.0 104 20.667 8 7.07 na 21.28 .2 100.75 7.0 105 20.667 8 7.4 na 21.76 .2 68.25 7.0 106 20.667 8 8.06 na 22.72 .2 68.25 7.0 5 20.667 9.36 na 107 20.667 8 7.71 na 22.22 .2 97.5 7.0 108 20.667 8 7.63 na 22.1 .2 99.13 7.0 109 20.667 8 7.62 na 22.09 .2 100.75 7.0 110 20.667 8 7.64 na 22.11 .2 100.75 7.0 111 20.667 8 7.85 na 22.42 .2 68.25 7.0 112 20.667 8 8.36 na 23.13 .2 68.25 7.0 7 20.667 9.47 na 114 20.667 8 7.88 na 22.46 .2 107.09 7.0 115 20.667 8 7.79 na 22.33 .2 108.87 7.0 116 20.667 8 7.78 na 22.31 .2 110.65 7.0 117 20.667 8 7.79 na 22.33 .2 111.65 7.0 118 20.667 8 7.99 na 22.61 .2 74.96 7.0 119 20.667 8 8.47 na 23.29 .2 74.96 7.0 9 20.667 9.72 na 120 20.667 8 9.67 na 24.88 .2 116.67 7.0 11 20.667 10.0 na 13 20.667 10.25 na 15 20.667 10.47 na 17 20.667 10.67 na 19 20.667 10.83 na 21 20.667 10.96 na 23 20.667 11.04 na 25 20.667 11.08 na 27 20.667 11.1 na 2 20.667 9.64 na 4 20.667 9.65 na 6 20.667 9.67 na 8 20.667 9.75 na 10 20.667 9.92 na 12 20.667 10.12 na 14 20.667 10.34 na 16 20.667 10.57 na 18 20.667 10.82 na 20 20.667 11.08 na 22 20.667 11.34 na 24 20.667 11.61 na 26 20.667 11.91 na 28 20.667 12.28 na TOR 20.667 14.52 na BOR 2.0 25.12 na 100.0 U 1 2.0 26.04 na U2 2.0 27.32 na U4 2.0 26.15 na U3 2.0 27.48 na BK 2.0 35.53 na TEST 2.0 35.76 na 150.0 The maximum velocity is 9.79 and it occurs in the pipe between nodes 28 and TOR Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Standard EAGLE FIRE PROTECTION PETCO Page 8 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 13.78 2.203 2T 13.639 88.250 9.345 K Factor = 8.00 to 120 8E 6.819 81.832 0.0 2 13.78 0.0018 170.082 0.300 Vel = 1.160 106 0.0 2.203 1 T 13.639 14.833 8.065 K Factor = 8.00 to 13.78 120 13.639 9.645 K Factor= 4.44 3 -61.78 2.203 1 T 13.639 30.130 9.343 Vel = 7.490 to 0.0 120 5E 6.819 47.736 0.0 100 -61.78 -0.0283 77.866 -2.201 Vel = 5.200 100 21.38 2.203 1 T 13.639 8.000 7.142 K Factor = 8.00 to 120 5E 6.819 0.0 0.0 1011 -40.4 -0.0129 8.000 -0.103 Vel = 3.400 101 21.22 2.203 4.292 7.039 K Factor = 8.00 to 120 0.0 0.0 102 -19.18 -0.0033 4.292 -0.014 Vel = 1.614 102 21.21 2.203 7.708 7.025 K Factor = 8.00 to 120 0.0 0.0 103 2.03 0.0 7.708 -0.009 Vel = 0.171 103 21.20 2.203 10.333 7.025 K Factor = 8.00 to 120 0.0 0.0 104 23.23 0.0046 10.333 0.048 Vel = 1.955 104 21.28 2.203 2E 6.819 7.708 7.073 K Factor = 8.00 to 120 13.639 0.0 - 10-5--.- 44.51 0.0154 21.347 0.329 Vel = 3,746 105 21.76 2.203 2E 6.819 6.958 7.402 K Factor = 8.00 to 120 13.639 0.0 06 6_6.27 0.0322 20.597 0.663 Vel = 5.578 106 22.72 2.203 1 T 13.639 14.833 8.065 K Factor = 8.00 to 120 13.639 0.0 4 88.99 0.0555 28.472 1.581 Vel = 7.490 0.0 88.99 9.646 K Factor = 28.65 5 -53.56 2.203 1 T 13.639 28.250 9.362 to 120 5E 6.819 47,736 0.0 107 -53.56 -0.0217 75.986 -1.649 Vel =_4.508__ 107 22.22 2.203 9.833 7.712 K Factor = 8.00 to 120 0.0 0.0 108 -31.34 -0.0080 9.833 -0.079 Vel = 2.638 108 22.10 2.203 10.167 7.633 K Factor = 8.00 to 120 0.0 0.0 109 -9.24 -0.0009 10.167 -0.009 Vel = 0.778 109 22.09 2.203 10.333 7.625 K Factor = 8.00 to 120 0.0 0.0 110 12.85 0.0015 10.333 0.016 Vel = 1.082 110 22.11 2.203 2E 6.819 7.708 7.641 K Factor = 8.00 to 120 13.639 0.0 111 34.96 0.0098 21.347 0.210 Vel ill 22.42 2.203 2E 6.819 6.958 7.851 -=--2.943-------- K Factor = 8.00 to 120 13.639 0.0 112 57.38 0.0247 20.597 0.508 Vel = 4.830 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard EAGLE FIRE PROTECTION PETCO Page 9 Date Hyd. Qa Dia. Fitting Pipe Pt Pt to Ref. 120 "C" or Ftng's Pe Pv ... Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 10.70 10.123 _-K Factor-= _3.36 13 112 23.13 2.203 1T 13.639 14.832 8.359 K Factor = 8.00 to 0.0 120 14 9.2 13.639 0.0 0.091 6 80.51 0.0461 28.471 1.313 Vel = 6.777 9.20 0.0 10.341 K --Factor-=-- 2.86 15 9.73 2.203 2T 13.639 82.250 80.51 to 120 9.672 K Factor _ 7 -55.96 2.203 1 T 13.639 26.417 9.466 to 120 4E 6.819 40.916 0.0 114 -55.96 -0.0235 67.333 -1.585 Vel = 4.710 114 22.45 2.203 9.833 7.881 K Factor = 8.00 to 120 0.0 0.0 115 -33.51 -0.0092 9.833 -0.090 Vel = 2.821 115 22.33 2.203 10.167 7.791 K Factor = 8.00 to 120 0.0 0.0 116 -11.18 -0.0012 10.167 -0.012 Vel = 0.941 116 22.32 2.203 10.333 7.779 K Factor = 8.00 to 120 0.0 0.0 117 11.14 0.0012 10.333 0.012 Vel = 0.938 117 22.33 2.203 2E 6.819 7.708 7.791 K Factor = 8.00 to 120 13.639 0.0 118 33.47 0.0091 -- ----- 21.347 ---- 0.194Vel --------- - - = 2.817 -- ---- - - ---- 118 - --- 22.60 ----- 2.203 2E 6.819 6.958 7.985 K Factor = 8.00 to 120 13.639 0.0 119 56.07 0.0236 20.597 0.487 Vel _ 4.719 119 _ 23.29 2.203 1T 13.639 14.832 8.472 K Factor = 8.00 to 120 13.639 0.0 8 79.36 0.0449 28.471 1.279 Vel=6.680 0.0 79.36 9.751 K Factor= 25.41 9 -8.50 2.203 1T 13.639 27.417 9.721 to 120 4E 6.819 40.916 0.0 120 -8.5 -0.0007 68.333 ---- -0.049 Vel = 0.715 - --- -- 120 - - -- 24.88 2.203 1T 13.639 60.875 9.671 K Factor = 8.00 to 120 4E 6.819 40.916 0.0 10 16.38 0.0024 101.791 0.247 Vel 0.0 16.38 9.918 K Factor = 5.20 11 10.70 2.203 2T 13.639 82.250 10.002 to 120 27.277 0.0 12 10.7 0.0011 109.527 0.121 Vel = 0.9.01- 0.0 10.70 10.123 _-K Factor-= _3.36 13 9.20 2.203 2T 13.639 82.250 10.250 to 120 27.277 0.0 14 9.2 0.0008 109.527 0.091 Vel = 0.774 0.0 9.20 10.341 K --Factor-=-- 2.86 15 9.73 2.203 2T 13.639 82.250 10.472 to 120 27.277 0.0 16 9.73 0.0009 109.527 0.101 Vel = 0.819 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Standard EAGLE FIRE PROTECTION Page 10 PETCO Date Hyd. Qa Dia. Fitting Pipe Pt Pt ', Ref. "Cor Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 0.0 9.73 10.573 K -Factor= 2.9,9--- 17 12.12 2.203 2T 13.639 82.250 10.667 to 120 27.277 0.0 18 12.12 0.0014 109.527 0.152 Vel = 1.020 0.0 12.12 10.819 K Factor= 3.68 19 12.20 2.203 2T 13.639 97.250 10.832 to 120 8E 6.819 81.832 0.0 20 12.2 0.0014 179.082 0.252 Vel = 1.027 0.0 12.20 11.084 K Factor = 3.66 21 20.10 2.203 2T 13.639 82.250 10.957 to 120 27.277 0.0 22 20.1 0.0035 109.527 0.388 Vel = 1.692 0.0 --- 20.10 11.345 K Factor = 5.97 23 24.85 2.203 2T 13.639 82.250 11.037 to 120 27.277 0.0 24 24.85 0.0052 109.527 0.574 Vel = 2.0-9-2---- 0.0 24.85 -11,611 K Factor -=--7.29 25 30.36 2.203 2T 13.639 82.250 11.081 to 120 27.277 0.0 26 30.36 0.0076 109.527 0.832 Vel = 2.555 0.0 30.36 11.913 K Factor = 8.80 27 36.76 2.203 2T 13.639 82.250 11.096 to 120 27.277 0.0 28 36.76 0.0108 109.527 1,185 Vel -=---3.094 0.0 36.76 12.281 - ----- K Factor = -10.49 1 -13.78 - - 3.314 11.083 9.345 to 120 0.0 0.0 3 -13.78 -0.0003 11.083 -0.003 -,-Vel = 0.513 -- ---- - ----- 3 61.78 3.314 7.875 9.343 to 120 0.0 0.0 5 48.0 0.0024 7.875 0.019 Vel = 1.785 5 53.56 3.314 10.708 9.362 to 120 0.0 0.0 7 101.56 0.0097 10.7080.104 ----- ----- - Vel = 3.778 7 55.97 3.314 11.667 9.466 to 120 0.0 0.0 9 157.53 11.667 0.255 Vel ,= 5.859 - 9 ---.-.0.0219 8.49 3.314 ----------- 11.667 9.721 to 120 0.0 0.0 11 166.02 0.0241 11.667 0.281 Vel = 6.175 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations -Standard ^ EAGLE FIRE PROTECTION PETCU Page 11 ' Date ' Hyd. Gm Dia. Fitting Pipe Pt P1 13 "C',xer. �� or Ftngb Pe Pv ^°°°°°° Notes Point Qt Pf/UL Eqv. Ln. Total Pf pn 11 '10i70 3.314 to 11.687 120 13 155.32 0.0212 13 -9.19 'Q]Q 3.314 to 10.472 ---- 120 15 -'------ 146.13 0.019C 15 49.73 3.314 to 36.76 120 -1T� 136.4 0.0187 17 '1212 3.314 to 120 19124.28 0.0141 19 '12.20 3.314 to 120 21112.08 0.0116 21 -2010 3.314 to 120 23 01.98 0.0080 23 '24.88 3.314 to 11.687 120 25 -'---- 6712 0.0045 25 '30.30 3.314 to 10.472 ---- 120 27 3876 0.0014 0.0 36.76 11.667 10.0O2 10.002 0.0 0.0 11.687 0.248 Val 5.777 11.087 10.250 0.0 0.0 11.007 Vel 5.435 11.887 10.472 ---- 0.0 0.0 11.667 0.195 Vel = 5.073 11.087 10.067 0.0 0.0 11.687 0.164 10.750 10.832 0.0 0.0 10.7500.125 9.833 10.957 0.0 0.0 9.833 0.079 9.833 0.0 9.833 10.417 0.0 10.417 11.037 0.0 0.044 11.081 0.0 U.015 ��� 11.096 Vel 4.623 Vo= 410S Facto = 1.367 2 13.78 4.31 0.750 9i045 to 120 0.0 0.0 4 13.78 0.0001 0.750 0.001 Vel= 0.303 4 88.99 4.31 0.758 0.845 to 120 0.0 0.0 102.77 ^ -- n u.002- �975U0.027 Vel 2.260___ h 80.50 4.31 9.750 0.072 to 120 0.0 0.O _8_ 183.27 0.0080 0.750 0.078 Vel = 4.030 0 70.36 4.31 10.708 9.751to 120 0.0 0.0 _10 _ 282.83 0.0157 10.708 8]G8 Vo|= 5775 10 18.38 4.31 11.007 9.918 to 120 8.0 8.0 _12 279.01 0.0175 11.667 0.204 Ve|= 6i136 12 10.78 4.31 11.067 10.122 to 120 0.8 0.0 14 _28Q71 0.0188 11.667 U210 _ Vel = 6.371 14 0.20 4.31 11.667 10.341 to 120 0.0 0.0 10 298.91 0.0199 11.667 0232 Val = 6.573 18 9.73 431 11.687 18.573 to 120 0.0 0.0 18 308.64 0.0211 11.667 0.246 Vel= 6.787 VelComputer Programs by Hydratec Inc. Route I 11 Windham N.H. USA 03087 �975U0.027 Vel 2.260___ h 80.50 4.31 9.750 0.072 to 120 0.0 0.O _8_ 183.27 0.0080 0.750 0.078 Vel = 4.030 0 70.36 4.31 10.708 9.751to 120 0.0 0.0 _10 _ 282.83 0.0157 10.708 8]G8 Vo|= 5775 10 18.38 4.31 11.007 9.918 to 120 8.0 8.0 _12 279.01 0.0175 11.667 0.204 Ve|= 6i136 12 10.78 4.31 11.067 10.122 to 120 0.8 0.0 14 _28Q71 0.0188 11.667 U210 _ Vel = 6.371 14 0.20 4.31 11.667 10.341 to 120 0.0 0.0 10 298.91 0.0199 11.667 0232 Val = 6.573 18 9.73 431 11.687 18.573 to 120 0.0 0.0 18 308.64 0.0211 11.667 0.246 Vel= 6.787 VelComputer Programs by Hydratec Inc. Route I 11 Windham N.H. USA 03087 'Final Calculations -Standard ' EAGLE FIRE PROTECTION Page 12PETCO Date ' Hyd. Qa Dia. Fitting Pipe Pt Pt ---- 18 1212 4.31 11.067 10.828 �------------ ' to 120 0.0 8.0 20 320.76 0.0226 11.887 0.264 Vel = 7.054 20 12.20 4.31 10.750 11.084 ---- to 120 0.0 0.0 22 332.90 0�U243 _ 10.75O Ci281 Vel = 7.322 22 2010 4.31 9.833 _ 11.345 _ to 120 12O 0.0 0.0 _24 353.08 0.0271 9.833 0.288 Vel = 77S4 24 24.85 4.31 0.833 11.611 to 120 128 O.0 0.0 28 377.91 0.0307 0.833 0.302 Vel = 8.310 26 30.36 4.31 10.417 11.913 to 120 0.0 0.0 28 _ 40827 _ 0.0354 10.417 0.389 Ve| = 8.978 28 3877 4.31 2E 13.937 26.125 12.281 to 120 27.874 0.0 _TOR 445.04 0.0415 53.990 2.242 Vel = 9.787 TOR 0.0 4.31 1A 23.693 20.000 14.524 to 120 1G 2.787 40.417 8.085 BOR 445.O4 0.0415 1Z 13.937 60.417 2.509 Vo|= 9.787 BOR 180.00 8.08 1E 21.411 52.000 25.117 Oa=10U����-------- to 150 1T 45.881 71.877 0.0 U1_ __545�4[i0875 1G 23,877 9.9.27 Vel =_8.023 U1 '247.54 7.88 2F 13.591 1042.000 28.044 to 150 27.181 0.0 U2 207.5 8.0006 1080181 1.279 Vel = 1.908 U2 0.0 0.79 1T 87.474 528.000 27.323 to 150 2F 14.844 126.840 0.0 U3 297.5 0.0802 1E 29.680 052.848 0.157 Vel = 1.268 0.0 297.50 27.480 KFoobor= 5875 U1 247.54 798 1T 52.855 178.000 28.044 to 150 52.853 0.0 U4 247.54 O.0OO5 230.853 0.107 Vel = 1.588 U4 0.0 7.98 2E 27.183 2739.000 28.151 to 150 OF 13.591 135.007 0.0 _U3__�'-_ 247�54 0�0085 2874�gU7 1�32Q Ve|= 1588 U3 297.50 0.79 2E 29.689 12.000 27.480 to 150 59.375 8.080 Fixed loss =8 BK � � 545.04 0.0007 71.375 0.053 Vel = 2.323 BK 0.0 970 3E 29.080 150.000 35.532 to 150 1T 67.474 163281 0.0 TEST 545.04O.00O7 _ 1G _ � 0�747 � 313281 � � 0.230 � _ Vel � ' � � 2�323 � � 150.00 Ou= 150.00 895.04 35.762 KFactor =11822 Computer Programs by Hydratec Inc. Routelll WindhamN.H.USA 03087 r, r SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: October 22, 2004 Business Address: 2201 W.P. Ball Blvd Occ. Ch. #36 Mercantile Business Name: Petco Ph. ( ) Contractor: Eagle Fire Protection Inc. Ph. (407) 656-8387 FAX (407)656-9405 Reviewed [ ] Reviewed with Rejected ( ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Instillation of One (1) types of design area. 20' ft Ceiling. Ordinary Hazard Group #2 (Storage shall not exceed 12' ft Per fire sprinkler original design criteria 167 total fire sprinkler head installation Application — Per N.F.P.A. 413-1999 Ed, Design System #1= Ordinary Hazard. Group #2 (Storage shall not exceed 12' ft Per fire sprinkler original design criteria ➢ General Sales Area (No Stock piles over 12') 167 Heads TOTAL ➢ Viking M3/4" Brass 200 degrees K=8.0 upright 142 ➢ Viking M3/4" Brass (with Recessed ESC) 200 degrees K=8.0 upright 24 ➢ Viking M3/4" Brass (SIDE WALL) 200 degrees K=8.0 1 • Tamper switches required on all inside and outside fire sprinkler valves 10 SANFORD FIRE DEPARTMENT FIRE PREVENTIONDIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407302-2520 / FAX (407) 302-2526 • Two hour above hydro, and flush required • Do not block access, and fire inspector test valves • Owner of property shall mark walls at 12' (ft) height to keep proper storage at all times 2 CONTENTS 1. VIKING SPRINKLERS 1-4 2. FLOW SWITCH 5-6 3. ELECTRIC BELL 7-8 4. ALLIED SCH. 40 BLACK STEEL PIPE 9 5. ALLIED DYNA-FLOW BLACK STEEL PIPE 10 6. GRUVLOK GROOVED PRODUCTS 11-14 7. THREADED FITTINGS 15-18 8. RING, HANGERS AND TOP BEAM CLAMPS 19-21 9. AGF INSPECTORS TEST 22-23 10. F.D.C. 24 11. O.S.&Y. VALVE 25 12. VIKING ALARM CHECK 26-31 May 2, 2003 Sprinkler 11 a 1, PRODUCT NAME Viking Micromatic® Model M and Micro- maticHP® Model M Standard Response Sprinklers -Available Styles: Upright, Pendent, and Conventional 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION Viking Micromatic® and MicromaticHP® Standard Response Sprinklers are small thermosensitive spray sprinklers available in several finishes, temperature ratings, and orifice sizes to meet design require- ments. The small frame and 5 mmglass bulb provide a pleasing appearance. Used in conjunction with one of the various cor- rosion -resistant coatings, the units provide protection against many corrosive environ- ments. In addition, the Polyester finishes and Teflon® coating can also be used in decorative applications where colors are desired. During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flow- ing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Viking Standard Response Glass -Bulb Style Sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap as- sembly removed) on deluge systems. 4. TECHNICAL DATA LISTINGS AND APPROVALS f s Upright Pendent Conventional Sprinkler Temperature Nominal Sprinkler Temperature Max. Ambient Bulb Classification Ratin _ Fusin Point) Ceiling Temperature' Color Ordinary 155 -F (68 -C) 100 Red Intermediate 17 'E -(79M_50 °F (6 Yellow Intermediate 20 °F 3 ° 150 °F 65 ° Green Y (_ ra Hiah 286°F f141 °C) _ 225 °F_(1pZ'C� e _ Extra Hiah 6 - (182 - 0 °F 14 ° Mauve . Ultra High°--------80Q_°F...(2§0..'C)_.... ..... .. - --46$ °E..(240 Sprinkler Finishes: Brass, Bright Brass, Chrome-Enloye, White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon® Corrosion -Resistant Coatings 3: White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon® in all tem- perature ratings. Wax -Coated Brass and Wax over Polyester finish5 for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax 175 °F (79 °C) Brown Wax 212 °F It 00 °C) Brown Wax ' Based on NFPA-13. Other limits may apply, depending on fire loading, sp=represent and other requirements of the Authority Having Jurisdiction. Refer to specific insds. 2 The temperature rating is stamped on the deflector. 3 The corrosion -resistant coatings have passed the standard corrosion test ap- proving agencies indicated on pages 11 b -d. These tests cannot and dt all possible corrosive environments. Prior to installation, verity through the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indi- cated are applied to the exposed exterior surfaces only and, therefore, the sprinklers can- not be used as open sprinklers. Note that the spring is exposed on sprinklers with Poly fin- ishes and Teflon coatings. n Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or sim- ilar enclosures with normal operating temperatures above 300'F (149 °C). Where the ambi- ent temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 5 Wax Over Polyester unavailable for S rinkler Base P/Ns 09992, 09993, 09994, and 09995. Refer to the charts on pages 11 b -d. Spacing Requirements: Max. spacing 15 ft. (4,6 m), min. spacing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65 °F (-55 °C). Spring: U.S.A. Patent No. 4,167,974 Min. Operating Pressure: 7 psi (48,3 kPa). RATED WATER WORKING PRESSURE Sprinklers 09992, 09993, 09994, and 09995 are rated for use with water working pressures ranging from the minimum 7 psi (48,3 kPa) up to 250 psi (1 724 kPa) for high-pressure sys- tems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (1 207 kPa) wwp. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-C51000, Brass UNS-C26000 or Copper UNS-C19500 for Sprinkler Base Part No. 09992. Brass UNS-C51000 or Copper UNS-C19500 for Sprinklers 10139, 10142, 10170, 10173, and 10223. Cop- per UNS-C19500 for Sprinkler Base Part Nos. 10138, 10141, 10169, 10174, 10187, 10190, 10193, 10220, 10233, 12105, and 12106. Brass UNS-C26000 for all other Part Nos. Bushing (for Sprinkler Base Part Nos. 09994, 09995, 10188, 10189, 10191, 10192, 10218, 10219, 10221, and 10222): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09992, 09993, 09994, 09995, and 10221: Bronze UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinkler Part Nos: Copper UNS-C11000 and Stainless Steel UNS-S30400 Note: Units of measure in parentheses may be approximations. Form No. F_100397 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (Part Nos. 12105 and 12106): Stainless Steel Wire Sprinklers with Teflon® Coating Belleville Spring Sealing Assembly: Ex- posed Screw: Nickel plated Pip Cap: Teflon® Coated Sprinklers with Polyester Coating or Poly Finish Belleville Spring Sealing Assembly: Ex- posed AVAILABLE FINISHES Brass, Bright Brass, Chrome-Enloy® (pat- ents pending), White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon® in all temperature ratings; Wax -Coated Brass or Wax over Polyester* for sprinklers with temperature ratings through 286 °F (141 °C). * Wax Over Polyester unavailable for Sprinkler Base Part Nos. 09992, 09993, 09994, and 09995. Replaces page 11 a -d, dated March 28, 2003 (updated the approval chart). Refer to technical data page SR1-2 for general care, installa- tion, and maintenance information. Sprinkler 11 b May 2, 2003 ® MICROMATIC® AND ® A A MicromaticW STANDARD RESPONSE SPRINKLERS -- ------ ---- Approval Chart Temperature KEY Micromatic® Standard Response Pendent Sprinklers *_ Finish MaximumlZ5_SJ_WWPI-A------....--------......--------- ........ _.... ........ Sa Thread Siz Max. Pressure Sprinkler Description Nominal Overall Listings and Approvals2 NPTI BSP PSIG Base Part Style SIN -Fact U.S. i metrics Inch mm cULus° FM NYC3 VdS LPCB lz 1_15mm _.175 Pendent .... 18139_.. _VK102..._...5.6 .B,1 _ 23116._56 .. _ - -------- -.... B2,D1],E13,F� B7.C6,.F7 !1.5mm __..]75 Pendent _I 017312 8,1 _. 23116 _56..__B],Q10,Ei3_ B9,C.12,A8 B1,..D10,E1.3. _ 168,.D3 'S Bt, D10, _ Eit 9 C12 -F9 61 - 31A -I, 20= 175 Pendent 10142 1 R1, D10 _ - - - 20 mm 175 Pendent 1zVK202 8.0 11-5 -31B -._....---,Ice9 ..Y2.-.. Ys"._L15_mm. __ _1.7.5 -.._..-Pendent P._endent. _,..0221...__. YK4.03 __1.022210 ... _VK0.04_ 6_ _..9,4_._... 2-.31-6- _..4Z__1___6.,SL....._ 2=114_ _56_ _58_ _._Iit,..D1.Q,.E1.3._.... _.__B9.,_D.12-_.................-__...__.__ __...-.__L_......_.-.._.___ Pendens. _� Q]7.5-- -YKOIl3 _9..2-- --..6_0..__ 2-]/_4 ._58._ ----_---.._—...._..._._..._ 10,12 _58 _ _.._._..__.._.._-_--__-_.._._-- -..88..._..88,...Q3. --.�-._....... _115. _==.__rnm...175_.._.....P_enden Q..1.89�°._tz ....V1S0.03 .2.8_1-4.®_2_31.1.6__.5fi._._B1_D_L0.,E13_. _..B9._D12_ Model E 1 o( E-2 Recessed Y2" 115 mm 175 PAnden VKin?l r, A At P-14/1 131 SIR I D2 8 D2 ns I D2 13 1 2 la t 10223 Di 0 Die - - „ 2_.q/JR 'r Ppnripnt inPP1s,io175 4,0 D1 175 Pendent sato -Eendent 10142 VK202 8.0 j 11,5 2-5/16 _59- DI s Dl_ P.endent.. 101731._2__. VK102C88.. 20mm.._Pendent.._101.701Z_ VK202. ._8_0 11-11,5--_ _2-318 60 --------- D1 _.... D88... - ! _......... .....D].__ 314 20mm __175 __..-Pendent.- ...._.1.2.1.0.5.-_.. V�S202.._.8_0i_t.,5_.. 23/.1.6._56_ ___._..._.___.-__._..__.._DLi_......__-.._.._. nstalled_w.th_the-V_'king..Microfast®.Mode F-]_..djustable-Escu. he.ons_1...._...._..._..__.........._...__.._...._.._._...._.__._........_............__ 2:7...' .5_mm .__].75__ ..P_e.ndent.. ____10.133__. _Vl(1. .__5.6.—L—B 1__..._ 2,3 - _6 _.56_.._______D2___..___.._.ES_.....__D2_. ..........1..75_._.......P.endent.....__ 1.0223._._ _VK202 ........._...___....__...---QL__._._.._....._._- 1i.4.15..mm..._..1..75_..__...P_.en.dent. 1022.1.910.. V.K0113___2B____ 4,0_ .23L1.6 _56_—__.._..Q.1_ _ ” 115 mm 9,10 1DI ES 1 Di -- Penden 1216 8_1 _ _ - : - 1017p12 VK202 12-3/8 16 - - - -1 Di Approved Finishes 1 - Brass, Bright Brass, Chrome-Enloya, White Polyesters, Black Polyesters, and Black Approved Temperature Ratings Teflon®5 2 - Brass Bright Brass, Chrome-Enloy®, White Poly Finishs , Black Polyesters, and Black Teflon65 A -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) 3 - White Polyester, Black Polyester, Black Teflon®, Wax -Coated Brass, and Wax over Polyes- 212 °F100 -C), 286'F ( ) 141 'C), and 360'F ter (182 °C )) 4 - White Poly Finish, Black Polyester, Black Teflon®, Wax -Coated Brass, and Wax over Poly B -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Finish °F °C), °F °C) 5 - Brass, Bright Brass, Chrome-Enloy® and White Poly Finish 286 (141 (182 and (79 6 - White PolyFinish and Wax -Coated Brass (corrosion resistant) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), titt o ( ) and 212 °F (100 °C) 7 -Brass, Chrome-Enloy and White Poly Finish D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F 8 -Brass, Bright Brass, an ®Chrome-Enloy® (93 °C) 9 - Brass and Chrome-Enloy E - 286 °F (141 °C 10 - Wax -Coated Brass and Wax Over Polyester (corrosion resistant) F - 500 °F (260 °C)y 11 - Wax -Coated Brass and Wax Over Poly Finish (corrosion resistant) 12 - Wax -Coated Brass (corrosion resistant) 13 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient lure allowed at cejlir]g = ° ° 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. XII. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion -resistant. 6 Metric K -factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiplythe metric K-factorshown by 10.0. I Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300'F (149 °C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra -High temperature rated sprinkler may be severely retarded. 8 FM Approval of Viking Micromatic® Standard Response Recessed Pendent Sprinklers installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon is limited to wet systems and preaction systems qualifying as wet systems, for hazard occupancies up to and including Ordinary Hazard, Group ll. 9 Listings and Approvals limited to Light -Hazard Occupancies with hydraulically calculated wet systems only. t'The sprinkler orifice is bushed. 11 Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be or- dered separately from sprinklers. Refer to Viking's current price schedule. 12Sprinklers 10173, 10170, 10189, and10188 are available on special order. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). May 2, 2003- Sprinkler 11 c Approval Chart Temperature KEY Finish MicromaticHP° Standard Response Pendent Sprinklers Al Maximum 250 PSI WWP Standar. ............... — ------ ..._-_...-- ---........_....__._...._... ----- -- .....__.... -.-........ - Thread Size Max. pprovals2Presu ___._........_...._..._.. Sprinkler Description Nominal K -Factor Overall Length Listings and A .._._..__._.__ ----- -----_............._.._ - NPT BSP PSIG Style ;Base Part Numberl SU.S. metrics Inch mm cULus3 IN FM NYC VdS LPCB 1/2" 15 mm 250 Pendent 09992 VK122 5.6 8,1 2-1/4 58 Ai - - - - Small Orifice6 '/2" 15 mm 250 Pendent 099947 ____.._..___.._......__ ­­ -_ -.._..-_......_._....._.___.___......__.__....._......._._....__.._..___.__......__-- ---._._. _.....____ ._....------...---......_...... Installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon9 '/2" 15 mm 250 Pendent 09992 VK122 1 5.6 8,1 2-1/4 1 58 61 - - - - '/2° 15 mm 250 Pendent 099946 VK023 1 2.8 4,0 2-1/4 1 58 B1 - - - - Installed with the Viking Microfast® Model F-1 Adjustable Escutcheon8,9 1/2" i 15 mm 250 Pendent ':. 09992 VK122 5.6 8,1 2-1/458 Al - - - - '/2" 15 mm 250 Pendent 099946 VK023_ 2.8 4,0 2-1/4 58 Al - - - - Approved Temperature Ratings Approved Finishes A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) 1 - Brass, Bright Brass, Chrome-Enloy®, White Polyester°, Black B - 155 °F (68 °C), 175_"F (79 °C), and 200 °F (93 °C) _ Polyester4, and Black Teflon64 Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 4 cULus Listed as corrosion -resistant. 5 Metric K -factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiplythe metric K -factor shown by 10.0. 6 Listings and Approvals limited to Light -Hazard Occupancies with hydraulically calculated wet systems only. 7 The sprinkler orifice is bushed. 8 The Microfast® Model F-1 Adjustable Escutcheon is considered a surface -mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 9 Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be or- dered separately from sprinklers. Refer to Viking's current price schedule. Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). Sprinkler Base Part No. 10139 Ceiling Opening Size: 2-5/16" (59 mm) Minimum,. 2-1/2" (64 mm) Maximum. with a standard 1/8" (3,1 mm) 2-1/8" surface -mounted escutcheon. 2-1 /8 (54 mm) (54 mm) ....._.. 11»C1�\ 2-1/4" 2" 1-1/2" (38 mm) 1-1/8" (28,6 mm) 1-3/4" (58 mm)(51 r mm) Minimum Minimum (44,5ax mm) Maximum* Maximum Sprinkler Base Sprinkler Base Part No. 10139 Sprinkler Base Part No. 10139 Part No. 10139 installed with a MicrofastO installed with a Micromatic® Model F-1 Adjustable Escutcheon. Model E-1 Recessed Escutcheon. Figure t ACCESSORIES Sprinkler Wrenches: A. Standard wrench: Part No. 10896W/B (available since 2000) or 05000CW/B (no longer available). B. Wrench for coated and recessed Micromatic® and MicromaticHP® Stan- dard Response Sprinklers: Part No. 07398W** (available since 1990), or Part No. 12144W/B**, available since 2003. NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W/B. **A '/2" ratchet is required (not available from Vi- king). Refer to the "Sprinkler Accessories" sec- tion of the data book. Sprinkler 11 d May 2, 2003 MICROMATIC" AND MicromaticHPO STANDARD SPONSE SPRINKLERS Approval Chart Temperature KEY Finish Micromatics and MicromaticHPO Standard Response Al and Conventional Sprinklers Maximum 175 PSI WWP Standard Orifice Thread Size ..... .......... . Max. Pressure . Sprinkler Description . ...... . ....... . .... .. Nominal K -Factor Overall L 2 Listings and Approvals . . ......... . .. . ........... ....... ............ ... . ­ .. . .. .... ...................... . ...... . ..... - . .. .......... NPT BSP PSIG Base Part! Style SIN Numberl z. U.S.-- Im-etric' I Inch mm 4 cULus FM NYC VdS LPCB 15 mm .1.75 . . .... . Upright 1 8,1 2-3116 B .,,E .2Fl4,.,Gl.0., A8, D7,,.G8 _132� E12,...Fl 43 . ... . .......... 1/2 15 mm 175 Uoriaht 10233 ::VK100 5.6 1; 8,1 2-3/16 56 A8, D7, 08 138 B9. E3 -- 15 mm 175 Unriaht 10174 [VK1001 5.6. 8 1 2 3L! 6 56 1 ­... - A8. D7� G8 E3 . . ...... 15 mmi ...... 175 r (1 5.6 8,1 1 12-3116 Milil, D T4,610, XW6i,68 Bl, Ell, F 43 - Large Orifice 1/2 " 15 mrn 175 Upriqht 10220 iVK200 8.0 11.5 2-3/8 60 B2. E12, F14, G10 B8, E13- _G8 B2, El 23 _ 3 3/4" 20 mml 175 Upright 10141 !VK200 8.0 1 11,5 12-5/16 59 B2. E12, F14, (310� f E13 G8 62 E12 F14 __ _7 B9 B9. E41 15 mml 175 Upright 10190 :VK200 8.0 115 12-3/8 60 Bl, Ell, Ft 4. Gi 0 B8 E13 G8 __ CL 20 mml 17r I Inrinht iniRQ vKqnn ;t n il 5 12-51'r ';Q PH P11 F14 B8. E13. 8 G8 B9 E3 Small Orifices 1/2', 15 mm 175 Upright 102189 ::VK001 2.8 4,0 2-3/16 56 Bl. Ell. Ft 4 Elo, E13 1/2 15 mm 175 Mp!jgNt 102199 !VK002 4.2 6,0 2-3/16 56 Bl, Ell, Ft 4 -- 15 mm 175 Upriqht 101919 VK002 4.2 6,0 2-3/16 56 Bl, Ell, Ft 4 15 mm 175 Uoriaht 101929 �VK001 2.8 40 2-3 16 56 81, Ell, Ft 4 E10, E13 10 mm 175 Upright 10176 !VK001 4.2 6.0 2-3/16 56 B8 B9. E3 Conventional 1/2 15 mm 175 Conv. 10227 VK1 18 5.6 8,1 2-3/16 56: Bl, Ell, Ft 4 BI El 1. Ft 41' B8 B5, Ell 3/4" 20 mm 175 Conv. 10228 �VK120 80 11 5 2-5/16 59 Bl, Ell, Ft 4 Bl, Ell, Fl 41' B5, Ell -- 15 mm 175 Conv. 1017210 iVK1 18 5.6 8,1 2-3/16 56 Bl, Ell, Ft 4 B5, Ell 20 mm 175 Conv. .. ..... . ....... 1016810 �VK120 . ........ . . ............... 8.0 11,5 . . 2-5/16 59 Bl, Ell, Fl 4 B5, Ell 3/4" Conv. 12106 8.0 11.5 12-5/16159 -------- - B8 Maximum 250 PSI WWP Standard Orifice 1/g " 115 mml 250 Upright 1 09993 jVK1241 5.6 1 8,1 Cl Small Orifices '/;;115 mm 250 Uoriahtl 099959 1VK02l 4.0 12-1/4 158F Approved Temperature Ratings A oved Finishes Brass, Bright Brass, Chr( Wite Polyester5, Black Polyesters, and Black Teflon0s 1 - )me-Enloy 5 005 A - 155 -F (68 -C), 175 -F (79 -C), 200 -F 2 - Brass, Bright Brass, Chrome-Enloy", White P?P Finish , Black Polyester5, and Black Teflon -C), 212 -F -C), 286 -F -C), 3 Polyester, Black Polyester, Black Teflon Wax -Coated Brass, and Wax over Polyester (93 (100 (141 1 -White and 360 'F (182 'C) 1 4 - White Poly Finish, Black Polyester, Black Teflonb, Wax -Coated Brass, and Wax over Polyester B - 155 -F (68 -C), 175 -F (79 -C), 200 -F 1 5 - Brass, Bright Brass, Chrome-EnloyO, White Polyester, and Black Polyester (93 -C), 286 -F (141 *C), and 360 'F 6 - White Polyester, Black Polyester, and Wax -Coated Brass (182 -C) 7 - White Poly Finish and Wax -Coated Brass (corrosion resistant) C - 155 -F (68 -C), 175 -F (79 -C), 200 'F 8 - Brass, Chrome-Enloya and White Poly Finish (93 'C), and 286 'F (141 'C) 9 - Brass, Bright Brass, and Chrome-EnloyO D - 155 -F (68 -C), 175 -F (79 -C), 200 -F 10 - Brass and Chrome-Enloya (93 *C), and 212 *F (100 *C) 11 - Wax -Coated Brass and Wax over Polyester (corrosion resistant) E - 155 -F (68 -C), 175 oF (79 oC), and 200 oF :12 - Wax -Coated Brass and Wax over Poly Finish (corrosion resistant) (93 -C) 113 - Wax -Coated Brass (corrosion resistant) F - 286 -F (141 C ) :14 - 200 -F (93 -C) High -Temperature Wax Coating (corrosion resistant); maximum ambient tem - 7 G -500'F(26 C) I perature allowed at ceiling = 150 'F (65 'C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. XII. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion -resistant. 6 Metric K-faclorshown is for usewhen pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-factorshown by 10.0. 7 Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300'F (149 *C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 oF (149 oC), the response time of the Ultra -High temperature rated sprinkler may be severely retarded. 8 Listings and Approvals limited to Light -Hazard Occupancies with hydraulically calculated wet systems only. 9 The sprinkler orifice is bushed. 10Sprinklers 10168 and10172 are available on special order. 'Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 111. 3pacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). Replaces page 11 a -d, dated March 28, 2003 (updated the approval chart). Refer to tech- Form No.F100397 nical data page SRII-2 for general care, installation, and maintenance information. UL ULC/Canadian Models Models WFD20 WFD20A WFD25 WFD25A W FD30 W FD30A WFD30-2 WFD30-2A WFD35 WFD35A WFD40 WFD40A W FD50 W FD50A W FD60 W FD60A WFD80 WFD80A Replacement Parts A3008-00 Retard Mechanism A77-01-02 Terminal Block 546-7000 Cover Tamper Switch Kit WFDW Cover Wrench WFDN4 Replacement gasket kit Product Overview New WFD30-2 models install in 2" hole sizes UL models are NEMA 4 rated Sealed retard mechanism assures that the retard is not contaminated by dust and dirt when the cover is removed Visual switch activation permits installer to accurately set retard under noisy conditions Rugged, dual SPOT switches are enclosed in a durable terminal block Accommodates up to 12 AWG wire 100% synchronization activates both alarm panel and local bell simultaneously uL © U C FM o LISTED APPROVED System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2" through 8", and can be mounted in a vertical or horizontal position. Robust Construction. The WFD series consists of a rugged, NEMA 4 rated enclosure. Designed for both indoor and outdoor use, the WFD series operates across a wide temperature range, from 32°F to 120°F. Reliable Performance. UL listed models are equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form Q synchronized switches are enclosed in a durable terminal block to assure reliable performance. False Alarm Immunity. The WFD series incorporates a mechanical retard fea- ture, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard's unique sealed design is immune to dust and other contaminants. Simplified Operation. The WFD series is designed to simplify installation. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field -replaceable. MEA approved Engineering Specifications Vane -type waterflow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6" from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24" from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2" - 8" pipes. The detector shall respond to waterflow in the specified direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mech- anism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or out- door use. Standard Specifications Static Pressure Rating 450 PSI Triggering Threshold Bandwidth (Flow Rate) 4-10 GPM Maximum Surge 18 Feet Per Second (FPS) Compatible Pipe: Steel water pipe, schedule SO through 40 Contact Ratings Two sets of SPDT (Form C) 10.0 A, 1/2 HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Overall Dimensions installed: t-•— 3.75- ------a Conduit Entrances Two openings for 1/2" conduit. One open, one knock -out type Operating Temperature Range 32*F to 120°F(0°C to 49°C) Enclosure, Rating* NEMA 4 - suitable for indoor/outdoor use Cover Tamper Switch Standard with ULC models Optional for UL models, part no. 546-7000 Shipping Weight W FD20: 4.2 Tbs. W FD40: 5.2 Tbs. WFD25: 4.3 tbs. WFD50: 6.3 tbs. WFD30: 4.5 lbs. WFD60: 6.8 lbs. WFD30-2: 4.5 lbs. WFD80: 7.5 Tbs. W FD35: 4.7 lbs. U b.1t Pipe Size t.6 - Pip. addle 2" 11/4" WFD25 WFD25A 21/2, Plpa WFD30 WFD30A I I Plaadc vane WFD30-2* WFD30-2A 3" Model Width Model Width W FD40 W FD40A 4" WFD21 4.6" WFD406.8" 2" W FD60 W FD60A 6" WFD25 4.6" WFD50 7.8" U boa WFD30 WFD30-2 5.2" 5.2" WFD6o WFD80 9.0" WIdN: Sx Tabl. WFD35 5.7" Ordering Information UL Model Numbers ULC/Canadian Model Numbers Pipe Size Hole Size WFD20 WFD20A 2" 11/4" WFD25 WFD25A 21/2, WFDW WFD30 WFD30A 3" 11/4" WFD30-2* WFD30-2A 3" 2" W FD35 W FD35A 31/2' 11/4" W FD40 W FD40A 4" 2" WFD50 WFD50A 5" 2" W FD60 W FD60A 6" 2" WFD80 WFD80A *UL listed only. System Sensor Sales and Service 8" 2" System Sensor Headquarters 3825 Ohio Avenue St, Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents On Demand: 1-800-736-7672 x3 Web: www.systemsensor.com Service Use Automatic Sprinkler: NFPA-13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Warranty 3 Years U.S. Patent Numbers 3,845, 259 4,782,333 5,213,205 Part Number Description A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper proof switch kit WFDW Tamer proof wrench for cover WFDN4 Gasket kit System Sensor In Canada System Sensor In China System Sensor In the Far East System Sensor In India Ph: 905.812.0767 Ph: + 86.29.524.6253 Ph: + 852.21919003 Ph: + 91.11.558.2119 Fx: 905.812.0771 Fx: + 86.29.524.6259 Fx: + 852.27366580 Fx: + 91.11.567.6815 System Sensor In Europe System Sensor In Singapore System Sensor In Australia Ph: + 44.1403.276500 Ph: + 65.273.2230 Ph: + 613.54.281.142 Fx: + 44.1403.276501 Fx: + 65.273.2610 Fx: + 613.54.281.172 Q 1999 System Sensor. The company reserves the right to change product specifications without notice. A05 -180-06-6/00(5K)-#545 n Models Available LIL/FM Models SSM 24-6 SSM 24-8 SSM 24-10 SSV120-6 SSV120-8 SSV120-10 ULC/Canadian Models SSM 24-6A SSM 24-8A SSM 24-10A SSV120-6A SSV120-8A SSV120-10A Weatherproof Back Box WBB Product Overview Approved for indoor and outdoor use System Sensor's SSM and SSV series bells are low current, high decibel notifica- tion appliances for use in fire and burglary systems or other signaling applications. Low current draw Reliable Performance. The SSM and SSV series provide loud resonant tones. High dB output The SSM series operate on 24VDC and are motor driven, while the SSV Three sizes available 6", 8", 10" series operate on 120VAC utilizing a vibrating mechanism. AC and DC models Simplified Installation. For indoor use, the SSM and SSV series mount to a standard 4 inch square electrical box. For outdoor applications, weather- DC models are polarized for use with proof back box, model number WBB, is used. supervision circuitry The SSM and SSV series come pre -wired, to reduce installation time. The SSM Mount directly to standard 4" square series incorporate a polarized electrical design for use with supervision circuitry. electrical box Engineering Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 6"/8"/10" (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi - flush mounting. Outdoor surface mounted installations shall be weather- proof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum pro- jection of 21/2". Bells shall be located as shown on the drawings or as U� determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor by Underwriters Laboratories and the California State ULI� FM MEA O use MEA. LISTED ,PP -0 approved Fire Marshal, and approved by Factory Mutual and i r Standard Specifications Operating Temperature Range —31°F to 140°F Operating Voltage SSM series 24VDC SSV series 120VAC Termination Service Use Provided with 2 sets of leads for Fire Alarm in/out writing General Signaling Burglar Alarm Warranty 3 years Model Gong Diameter (inches) Nominal Voltage Operating Voltage Range Average Current Draw Sound Output (dB) SSM24-6 6 Bell, 8", 24VDC, Polarized, 85dba SSM24-10 SSM24-1OA 85 SSM 24-8 8 24VDC 19.2 to 26.4VDC 0.O3A 85 SSM 24-10 10 Bell, 10", 120VAC, 82dba WBB 85 SSV120-6 6 82 SSV120-8 8 120VAC 96 to 132VAC 0.O47A 85 SSV120-10 10 82 * Sound output measured at Underwriter Laboratories, as specified in UL464 Ordering Information. UL/FM Model Numbers ULC/Canadian Models Description SSM24-6 SSM 24-6A Bell, 6", 24VDC, Polarized, 85dba SSM24-8 SSM24-8A Bell, 8", 24VDC, Polarized, 85dba SSM24-10 SSM24-1OA Bell, 10", 24VDC, Polarized, 85dba SSV120-6 SSV12O-6A Bell, 6", 12OVAC, 82dba SSV120-8 SSV12O-8A Bell, 8", 120VAC, 85dba SSV120-10 SSV120-1OA Bell, 10", 120VAC, 82dba WBB Weatherproof Back Box for SSM and SSV series, when installed outdoor System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China 3825 Ohio Avenue Ph: 905.812.0767 Ph: 011.86.29.524.6253 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 011.86.29.524.6259 a Ph: 800-SENSOR2 System Sensor Europe System Sensor in Singapore Fx: 630/377-6495 Ph: 011.44.1403.276500 Ph: 011.65.273.2230 Documents on Demand Fx: 011.44.1403.276501 Fx: 011.65.273.2610 1-800-736-7672 x3 www.systefnsensor.com © 1999 System Sensor. The company reserves the right to change product specifications without notice. System Sensor— Far East Ph: 011.85.22.191.9003 Fx: 011.85.22.736.6580 System Sensor— Australia Ph: 011.613.54.281.142 Fx: 011.613.54.281.172 A05,260 -03-11/99(10K) • N573 U -cc du 1 0 Fully Listed and FM Approved Sprinkler Pipe p When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule- l0/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1 %4"- 8") pipe and Sch-40 (I"- 2%Z") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 product can be "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Schedule-10/Schedule-40 pipe are in compliance with the following.- ASTM ollowing: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture '� • Vibration Test ttgull Flow Control \TJ allied TUBE & CONDUIT UL FM USC Listed t Specificatibns 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WVLift (21') WVLift (24') WVLift (25' In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1'/<' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1'/z' 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2'/z' 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 ttgull Flow Control \TJ allied TUBE & CONDUIT UL FM USC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WVLift (21') Wt/Lift (24') WVLift (25' In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1'/," 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1'/z' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2'/z' 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5' 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6' 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 ttgull Flow Control \TJ allied TUBE & CONDUIT UL FM USC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 DynawFlowe High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule -10. Dyna -Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna - Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule -10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna -Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11 % larger than Schedule -40 and up to 7% larger than Schedule -10, Dyna -Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna -Flow, and related components, to be down -sized within the system, thus increasing the potential for job cost savings. For complete Hazen - Williams charts, refer to "Dyna -Flow Hydraulic Data Tables." Dyna -Flow products are coated with Dyna-Flow/Super Flo pipe is manufac- Lightweight and easy to install, an environmentally approved and tured to meet ASTM A-795 Type E, resulting in more efficient use of your specially formulated modified -acrylic or Grade A and is in compliance with freight and labor dollars. water-based coating. This durable coating NFPA-13 and NFPA-14. All sizes of is paintable. The black coating acts as Dyna Flow/Super Flo are UL Listed, FM an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. tgco/Flow Control Approved and ULC Listed. U� FM USC Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end, and welded joints for wet4 systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. • Provides stability needed to comply with standard hanger spacing (15 ft 0. C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. �II'�d 16100 S. Lathrop • Harvey, IL 60426 Customer Service: T11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 0 NPS Nominal I.D. Wt. Wt. (1120 Filled) Pcs/ Wt/Lift (21') Will (24') WVLift (25' In; mm In; mm Lbs/Ft; Kg1m Lbs/Ft; Kg1m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1'/" 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 1'/z" 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2" 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2Yz' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3" 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4" 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna -Flow products are coated with Dyna-Flow/Super Flo pipe is manufac- Lightweight and easy to install, an environmentally approved and tured to meet ASTM A-795 Type E, resulting in more efficient use of your specially formulated modified -acrylic or Grade A and is in compliance with freight and labor dollars. water-based coating. This durable coating NFPA-13 and NFPA-14. All sizes of is paintable. The black coating acts as Dyna Flow/Super Flo are UL Listed, FM an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. tgco/Flow Control Approved and ULC Listed. U� FM USC Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end, and welded joints for wet4 systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. • Provides stability needed to comply with standard hanger spacing (15 ft 0. C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. �II'�d 16100 S. Lathrop • Harvey, IL 60426 Customer Service: T11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 0 ff.Zf� ��Fire Protection Products l Submittal Sheet Figure 7400* Rigidlite® Coupling The Figure 7400 Rigidlite Coupling from Gruvlok is specially designed to provide a rigid, locked -in pipe connection to meet the specific demands of rigid design steel pipe. Fast and easy swing -over installation of the rugged lightweight housing produces a secure, rigid pipe joint. The Figure 7400 Rigidlite Coupling is UL Listed and FM Approved for 300 psi (20.7 bar) fire protection service in both wet and dry systems with roll grooved or cut grooved steel pipe prepared in accordance with Gruvlok grooving specifications. The Figure 7400 Rigidlite Coupling with a DRI-SEALTm style gasket is intended for use in fire protection systems installed in accordance with NFPA Standard 13 "Sprinkler Systems". ■ryp® �, iry[ nom— Available galvanized When ordering, refer to product as FP7400. Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: Approval Stamp: 01RIGIOLIT&COOPli Range of Max. Wk. Max. End Pipe End Coupling Dimensions Coupling Bolts Approx. o?�1SD*4aebCtx�T�-01,• Sizi:a>a In./QN mm In./mm PSI/bar Lbs. /kN In./mm InAmm In✓mm In./mm QtY, In./mm Lbs./1C 11/ 1.660 300 649 0 - 1/4 250 43/ 13/ 2 -34x 2V 1.3 1'/ 1.900 300 851 0 - 10 27/4 47/1 13/ 2 3A x 21/ 1.4 2 2.375 300 1,329 0 - 10 31/ 5V 13/ 2 3/4x 210 5: 1.6 21h 2.875 300 1,948 0 - 1/6 37/1 6 13/ 2 3A 21/ 1.9 3 3.500 300 2,886 0 - 10 4�1A 63/ 13/ 2 30x 23/ 2.1 4 4.500 300 4,771 0 - 1/ 55A 73/ 1'A 2 30x 230 ' 3.5.;71 5 5.563 300 7,292 0-1/1 Erb / 91 2' 2 'f x 3 4.6 6 6.625 300 10,341 0-1/1 77/1 103/5 2 x 3 5.5 8 8.625 300 17,528 0 - JA 101/1 12Y- 234 2 IAxrt3 8.4 19 1 Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: Approval Stamp: Fire Protection Products T Submittal Sheet Figure 7050S* Standard 90° Elbow for Fire Protection When ordering, refer to product as figure FP7050S. 0' —Available Schedule 10 F— Available galvanized Above fittings are all cast malleable or ductile iron Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. fig' Fire Protection Products Submittal Sheet Figure 7060S* Standard Tee for Fire Protection * When ordering, refer to product as figure FP7060S. Project: Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: ANVI.L [:] 0 — Available Schedule 10 F -I 42EF— Available galvanized Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: H ISI Max. Rated Center Approx. N OM.Size 7 Pipe OD Pressure to End Wt. Ea. Am, %T 11/4 1.660 300 2Y4 1-5 i 1h 1.900 300 23/4 1.8 2 2.375 300 31/4 2.4 214 2.875 30-0 3 3.500 300 41/4 5.8 4 4.500 300 5 10.3 5 5.563 300 514 16.2 6 6.625 300 614 25.7 !-63 8 8.625 300 7 �Y4 41.1 Project: Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: ANVI.L [:] 0 — Available Schedule 10 F -I 42EF— Available galvanized Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: H UYKA.A �y Fire Protection Products NO Submittal Sheet Figure 7072 Concentric Reducer EtoE EtoE CAST WELD Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: �, INTEn NA LiDNAE. IN<. n ®i —Available Schedule 10 F] Available galvanized ■ - Cast malleable or ductile iron, all others are fabricated steel. Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: mm—alleable Iron Class 150 (standard) 1 it'�� NVIiM `\�1` �% \7 ��) IN TERNAiIONAE, INC. ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.onvilinti.com (12/10/01) Size A Weight (lbs) L90'bow 1101 (NPS) (in) black galy. i "/16 .06 .07 .12 i 5/16 17 17 /z 1'/8 .26 t 2 7 15/16 .38 43 1 1'/z 63 65 j 1'/4 .96 .94 1'/2 - 115/16 1.30 1.34 2 .... 21/4 _..__ 2.06 _ . ....._.....f 2.01 2,V16 3.54 3.64 - A ' f f 3 3'/,6 5.20 5.35 3'/z 3/16 7.10 7.19 4 31x/16 8.95 9.37 5 4'/2 13.90 14.50 6 5'/B 23.00 i 23.50 ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.onvilinti.com (12/10/01) Malleable Iron Mass 150 (standard)ANVITM :� /�'/ IrviERNATIONA, INC. Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Pressure,(psig) Temp — ff) Class Class Class 150 250 300 _20* to 150° 300 500 600 200° �T265— j-455 ..-_._...550-- 250 225 I...405 505 300° 185 j 366 460 350 1.50 ...;......_...315 415.. . t _....... _._.._... 1 400' 10 270 370. 450 75 225 325 500° .... .. 1 - 180. 280 ... 550° -- 30 230 -- Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F Anvil Class 150 (Standard Weight) Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16-39. Anvil standard weight banded pattern fittings in this catalog, sizes ''A NPS to 6 NPS inclusive, are included in the "List of Inspected Fire Protection Equipment and Materials" issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED ATA MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01} 1 �o Malleable Iron Threaded Fittings Pressure -Temperature Ratings i Pressure, (psig) Temp Class 300 (°F) Class 150 ? Sizes I Sizes Sizes 1/4"-1.. 11/4"-2" 21/z"-3" i -20 to 150 300 2,000 1,500 1,000 265 1,785 1,350 .... _._.. 910 f — 250 _ 225 1,575 1,200 825 300° .. 185 1,360 1,050 _. ......I. 735 350 150 1,156 900 v650 p 400 935750 560 i 225 600 475 ..... _. .._......_ 500° ......._ 510 450 ..........E 385 550............ . 300 300.. 300._._.._.. Fire Protection Equipment and Materials" issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED ATA MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01} 1 �o Al Malleable Iran Class 150 (standard) NVI L 4- INTERNATIONAL, INC. Reducing Tee Figure 1105R Size Size (NPS) X y Z (in) (in) (in) Wt. (lbs) black gale. Vs 1 Vs 1 /4 1 /4 i 3A 'h .12 .14 1/4 V, 3f. S/16 'A 1 .19 1 .20 1/4 '/8 V2 S/1 6 "/16, "A 6 1 I YS 1 i 1'/a 7T1 1 22 .29 1/41 3/, '/2; 1/8 'A 'A, 1'/1611'/16 1 VI 6 1 .21 .26 i.29 'A i V? V IS i 5/16 1'/a -F- TO 3-1 3/8 3/8 j 1 1/16 .92 '14 '/4 1'/16 1 1'/16 1 /16 1 1'/e V4 13A6 3/, % 1114 i .30 1 .32 .43 '1 .45 .55 .57 '14 is i 1 '/s 15/16 .45 .46 3/8 1'/e 1/16 1 36* '/4 15/16 1 .46 .48 12 '/16 V .43 .47 3/4 15/16 1 .51 .51 1/4 1'/16 1'/16 .38 .40 Vs 1 1 Vs 1'/e 1 1'/e .42 .46* '3 'A 12. 1/16 1'/f6 1'A .45 .49 1 .5 1.5 1'/16 i 1'/16 1'/e i .62 .66 114 I 11/8 1/8i 1 1 VIG .90 .93 1/4 1s/16 1'/2 i .69 1 .71 2 1 4 3/o .55 .55 V, '14 1'/e 11A 1 11/,6 1 .56 1 .62 I 1 1 1'/2 i 1'/e 1 1112 1 .76 .73 112 i 1'/4 1 1 .59 .62 : '/4 7 I 1-/81� 11/16 i, /16 .73 .75 11 I/Z 11/16 1'/2 .78 .81 'A 1'/e 1'/e 1'/4 1 .55 i .55 4 11/4 j 1'/et .70 i .74 1/4 11/0 1'/e 1'/16 .82 .84 I'M 1 11/ .92 1 .97 11/0 1.19 1 1.24 2 2 2 1 1.63 1 1.6 Size X Y Wt. (lbs) (NPS) I , (in) (in) black ��a I v. I 6 1 -Na 12 .87 .94 1 '/4 1'/d 1 I/ti; 1314 1.04 1.07 3/4 '/16 i 1,/16 15/3 .86 .86 3/, .68 _96 i 1 'A 1'/4 1'A 1 1'/d 1-09 :1.10 '12 1'/8 .76 .79 6 1/8 1 11/8 .87 .92 1/4 1'/2 j 1 "/, 6: 1.11 1.13 1 3A 1F, , 1 A 1 13A i 1.13 ' 6 . 1.19 3/0 1'/4 /4 6-8 9 '/21 1% 3/1 '/,s i .98 .98 '14 1 1'/,6 1 1'/16 1s/8 1.06 1.10 1/16 11.61 1 1 1 1'/16 11 "/16 1.18 1.22 1'/z! 1 '/s 1'/e I 13/16 1.45 1.40 2 1 2'/8 2'/e i 1'/o 1.70 1.82 1 '12 11 16 1 16 115/16 1.35 1.42 1'/2 1 6 1'/4 114 15/e 115/' i 2 '/4 .56 'A i 1'/2 1 '/16 1 1114 1.00 1.03 1'/2 1''/16;1 13/16 1 1 "/16 1.50 i 1 .5 1.5 1 '14 i 1 ' '/16 1 11 'As i 1'/x 1.30 1.44 6 '/2 1'/16 1'/e 1 Vj 6 1 1.03 1.10 3/4 1'/2 1'/16 1 1.08, �11 0 !1'/4 1 15/e i 1'/16 it "/16! 1.26 1.27 1'/4;1 "/I6 i 1'Y4 1 'Is 1.52 i 1.42 l'/2 -5/16 1'/e 1'5/16' 1.50 1.55 '12 17/15 i 1'/16 1 "/16 1.19 1.25 i Ij 1, 7 3, 'h' 1 '12 1112 13/4 1.29 1.40 1/2 11/6 11/3 13/16 1 13/16 1'/e 1.44 1.45 1.4 9 1.47 2 2'/I62'/16 2 1.86 2.01 '12 1 2 21/4 1'/s 2'/4 1 2.14 i 2.25 3/4 2 1 2'// j 115/16 i 2/4 i 2.00 1.97 2 2A 2'14 ' 1 2 2.14 2.28 1'/4 171. !FiT/�. i 1-72- 1,79 1 'A 1 1 `/2 I2 1/75 /16 2 1.85 2.00 2 i 21A 2'/e j 2'/4 2.20 2.25 11/4 1/e 2 1.58 11.61 1'/s i 1 '/16 11 2'/e 2 11'/2; 1'h 2 1115/16! 2/16 1-76 1.95 1.83 1.95 2 2'/d 12'/16 2 Vs 2.24 2.39 1/2 11/2 1'/2 17/. i 1.65 1.70 114 15/e 115/' i 2 1.87 1.90 1 13/4 11/, 1: 2 2 1.79 2.00 M 1I 11/8 2'/e 2.35 2.55 1 '122 2 2'/,6 2.55 2.65 2/21 2'/s 2 2'/s 3.50 3.59 www.anvilinrl.com (12110101) Size X y Z Wt. (lbs) (NPS) (in) (in) (in) black galv. i 2 231/s 1 23/16 1'/2 2 'Is 3.43 3.51 2'/2 21 'A s, 2112 2 "/,6. 3.80 3 80 2 211s i 3-28 j 3.32 2/2; 2 25A 675�- 4.10 '14 1 13/4 1 13/, 21/2 21/16 2.82 2.80 '/s 'I I 'A 23A i 2.85 i 3.00 1'/e' 2'/16 2A 6 21/2 211,6 j 3.34 31.47 1 2'/16 2 YI 6 2 1/z 1 3.46 3.57 5 2 2'/e 21/s 3.65 3.75 3 3 3 '213/,Gl 5.82 6M 5 8 0 0 2 21/24.10 2 '/4 1 0 1 2'/o i 4 10 4.30 0 211, iTA T6 07 j 6.53 1 2 1 2'/2 2% 2'/2: 21A 1 4.80 1 4.85 3 5-80 1 5.91 'A 1'/e 1'/e i 2 Ya 4.02 4.22 3 1 2 i 2 1 21A 1 4.15 14.36 TIT 2'116 1 2'/161 23/4 1 4.68 4.67 3 1 2/111 2/16 2'3/16 5.11 15.26 2 2V2 2 V2 5.79 5.81 2'/212'3/16 2 "/16! - 3 -6--096.2 2 3 4 i3"/,6 3 '/a3 T/1 6 1 1,80,11 00 4 2 2'/4 2'/4 3A6 i 8.39 8.80 4 21/2 3/, 6 VA6 9 8 9.2 5 3 35/16 3/16 31/o 111.02 111.30 1 www.anvilinrl.com (12110101) Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Pressure,(psig) Temp (°F) Class I Class Class i 150 250 i 300 20 to 150'300 1 500 600 _. 200' 265 1 455 550 250 225 405 505 300° 185 360 460 _..__..._.....3.5.0.0.__.._........_.._...1.50 x___31..5.._..._...,...... 415 __... 400.0_..._ . _.. 110 1......270 370 ..-----...... ........... _,.__.___.__.... .__._•.___._ ._._....___..._:............. ......._..._.. 450° 75 i 225 325 --500° 180 _ 280- --5.50.x_.. -'- ._._.._._....._...... -130 ....1..._.._._2.3.0_...._.... Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F All WIL ti Hl Anvil Class 150 (Standard Weight) Malleable Iron Fire Protection Equipment and Materials" issued by the Underwrit- Fittings conform to ASME B16.3 and Unions conform to ASME ers' Laboratories, Inc. 1316.39. ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED AT A MINIMUM Anvil standard weight banded pattern fittings in this catalog, sizes OF 100 PSI. '/a NPS to 6 NPS inclusive, are included in the "List of Inspected www.anvilinti.com (12/10/01) iQ U PIPERlNyGS&' ° y �Y & tza7 Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards H - Size Range: 1/2* through 8' Material: Carbon steel Finish: ❑ Galvanized Service: Recommended for suspension of non -insulated stationary pipe line. Maximum Temperature: 650° F Approvals: Complies with Federal Specification A -A -1192A (Type 10) WW -H -171-E (Type 10) and MSS -SP -69 (Type 10). UL and FM Approved (Sizes 3/4' - 8') Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2' through 3' sizes. Ordering: Specify size, figure number and name. i.'.�A Project: . Date: Contractor: Address: Notes 1: Notes 2: Pipe Hanger Submittal Sheet TArchitech /Engineer: . Phone: . Approval Stamp: Fig. 69: Loads (lbs) • Weight (lbs) • Dimensions (in) Pipe Size Max Load Weight ROA 1Ze B C F '/2 0.08 i21/4 1 3/8 3/4 o . 09 125/16 1 '/16 0.1 —� 27/16— 9/16 _._ 1/6 — 300 - -- --- --i - ----- 11/4 0.10 Z 5/8 1 3/4 3/8 1'/2 0.10 i 23/4 11/6 - _._1 2 0.11 1 31/4 23/8 1'A 21/2— !0.20 4 23/4 .1 5/16 -'i 525 3 0.20 i 43/8 31/8 t-- 13/8 - - ------------- 4 -- 650 ----- 0.30 I 411/16 ------ 313/16 - - '---- --—�'--__------ ' -----!----^—---'---------� 1 9/16 5 0.53 55/16 43/6 6 1,000 ._. _6 ---- ........ ----- -------- 0.80 '/z i67/16 5'/2 23/1s 8 1.00 I 8 7 211,16 Pipe Hanger Submittal Sheet TArchitech /Engineer: . Phone: . Approval Stamp: e Fig. 146 Continuous Threaded Rod Size Range: 1/4° through 11& Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel; rod threaded complete length. Finish: ❑ Plain or O Galvanized, Maximum Temperature: 650° F. Ordering: Specify rod diameter and length, figure number, name and finish. Length — f A Fig. 146: Loads lbs • Weights lbs Dimensions in Rod Threads i Max Load Weight Size Inch........... 650° F per Ft.................... ..._A ......................_per /a 20 240 0.12 3/8.... 16 .._..... .11 .. 730 ........ 0 30... Vz 13 1,350 0.53 j 5/e 11 2,160 0.84 i i 3/410 3 2 3 0 ... 1.2.0.. 7/8 9 4,480 1.70 1..._ 8 _._ 5,§b0. 2.30 1 /4_ _ 7 ....... 9 500...... 3.60 ..... 11/2 ...... ....._.. 6 13,800 5.10 j Note: Other rod sizes available upon request Class 2 fit is available upon request. Approval Stamp: "Zo BEAM CLAMPS 3- ClampFig. 92 Universal C-type (Standard Throa Size Range: 3/8 and 1/2° Material: Ductile iron, hardened steel cup point set screw and focknut. Finish: ❑ Plain or O Galvanized Service: Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4'. Approvals: Complies with Federal Specification A -A -1192A (Type 19 & 23) WW -H- 171-E (Type 23) and MSS -SP -69 (Type 19 & 23). UL, FM and ULC Approved. How to size: Size of clamp is determined by size of rod to be used. Installation: Follow recommended set screw torque values per MSS -SP -69 (See table on page PH -212) Features: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup -pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. Ordering: Specify rod size, figure number, name of clamp and finish. G 3'i JAM - NUT _ SETSCREW _ E AT LEAST ONE I i FULL THREAD T i OF ROD MUST BEEXPOSED I D BODY CASTING E_j I � I +A 1i Fig. 92: Load (lbs) • Weight (lbs) • Dimensions (in) Rod Size Set Screw Max Loads ■ A SizeWeight i C D E F G H Top Bottom 3/B 3/6 i 500 250 0.3 4 1 5/16 1 9/16 9/16 13/16 3/8 1/2 1/2 1/2 950 760 0.63 13/6 113/16 1/2 1 11/16 2/16 I I 23/32 ■Maximum temperature of 450° F Project: Date: Contractor: Address Notes 1: Notes 2: Pipe Hanger Submittal Sheet Architech /Engineer: . I Phone: . Approval Stamp: �Z I N EVi MODEL 3011 REMOTE INSPECTORS TEST FOR SYSTEMS REQUIRING PRESSURE RELIEF VALVES OLD WAY NO ORIFICE REQUIRED ADVANTAGES Test orifice Located Indoors To Prevent Freezing. • Assembly Includes Integral Pressure Relief Valve With Drain Piping. • Guarantees Pressure Relief Valve Access To The System. • Eliminates Need To Drain The System After The Hydrostatic Test To Install Required Pressure Relief Valve. • Hours Wasted In Testing, Draining, Reactivating And Component Installation Are Now Reduced To Minutes. • Model 7000 Pressure Relief Valve Equipped With Flushing Handle To Remove Dirt Causing Drip Leaks. ❑ The AGF Manufacturing, Inc. Model 3011 Inspector's Test Performs The Remote Inspector's Test Function With The Added Feature Of An Integral Relief Valve. ❑ The Model 3011 Inspector's Test Valve Complies With The Requirements Of NFPA 13 For The Installation Of A Pressure Relief Valve On All Gridded Systems And Downstream Of All Pressure Reducing Valves. Cl Designed To Relieve Excess System Pressure Caused By Surges Or Temperature Changes As Well As Solve The Difficult Problem Of Providing The Relief Valve With A Drainage Piping Outlet. ❑ The Model 3011 Inspector's Test Valve Is Available With Test Orifice Sizes Of 3/8", 7/16", 1/2", 17/32" And 5/8" (ELO). ❑ The Model 3011 Inspector's Test Valve Is Shipped With All Necessary Components Included. ❑ To Expedite System Testing The Unit Is Shipped Semi Assembled With The k out New Auto Relief Valve Port And The Bypass Drain Port Plugged. 0%,XC G� Visit us '90 ❑ The Included UL/FM Model 7000 PRV Features A Flushing Handle Gre on the Internet sZ" 19/ And Is Factory Set At 175 PSI With Other Settings Available. at 6/01 4Q1:M=01> MODEL 3011 1" PIPE SIZE 3 1/16" 4 11/1sr e 75.48mm 118.23mm MATERIAL LIST PART: HANDLE STEM BALL BODY VALVE SEAT RELIEF VALVE UPSTREAM SEATS pip ®'. FLOW DOWNSTREAM SEATS Figure A Valve seated in "OFF" position. Flow from inlet of valve to side outlet into relief valve. 7a f MATERIAL: STEEL ROD BRASS C.P. BRONZE BRONZE VIRGIN TEFLON BRONZE UPSTREAM SEATS FA O+ LLI DOWNSTREAM SEATS Figure B Valve seated in "TEST" position. Flow from inlet of valve to straight outlet of valve through orifice in ball. 4 7/811 123.56mm From the February 1, 1994 Edition of NFPA 13: Paragraph 4 - 6.1.2.3 requires a relief valve be installed downstream of all pressure reducing valves. Paragraph 3 - 1.2 requires ALL GRIDDED SYSTEMS be provided with relief valves. AGF MANUFACTURING, INC. JOB NAME: 100 Quaker Lane Malvern, PA 19355 USA ARCHITECT: Telephone: (610) 240-4900 Fax: (610) 240-4906 1= MADE IN U.S.A. ENGINEER: www.testandrain.com Thank You For Using Our Products CONTRACTOR: L A Al IJV 17- UL n A c L E D 9; 6 FM �_ 5;6 �n U� i C { 12 FM 0° —� EXPOSED STANDPIPE/AUTO SPRINKLER SIAMESE Elkhart 156 brass wall type siamese connection has two individual clapper valves, plugs and chains. Escutcheon lettered "Standpipe," Auto-Sprk," or "Standpipe and Auto-Spkr." Finish: Polished brass. Optional: Polished chrome plated. Specify size and thread: 21/2" x 21/2" x 4" 21/2" x 21/2" x 6" Size A B C D E F 21/2 x 21/2 x 4 117/8 65/e 111/16 85/8 12'A 49/16 21/2 x 21/2 x 6 117/. 65/a 111/,6 1013/,6 j 121/4 6„/,6 (Dimensions in inches) Elkhart 11 Siamese -Single Clapper, lightweight, cast brass lettered "Auto-Spkr” One swinging brass clapper valve. Complete with brass swivels. Threads to local fire department specifications. Plugs and chains available at extra cost. Finish: Cast brass. Specify thread: 21/2" x 21/2' x 4" Elkhart 18 Three -Way Standpipe Siamese. Independent drop clap- per valves. Plugs and chains available at extra cost. Threads to local fire department specifications. Finish: Body painted red, cast brass trim. Optional: Polished brass or polished chrome plated trim. Specify thread: 21/2" x 21/2" x 21/2" x 6" Elkhart 12 Two -Way Standpipe Siamese. Cast brass standpipe or sprinkler siamese. Two individual drop clapper valves. Plugs and chains available at extra cost. Specify tettering: "Standpipe" or "Auto-Spkr." Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plated. Specify size and thead: 21/2" x 21/2" x 4" 21/2" x 21/2" x 6" Size A j B C �- 21/2 x 21/2 x 4 79/16 ! 115/16 5'/4 2112x21/2x6 I 10 i 11Y2 71/2 (Dimensions in inches) Elkhart 10 90° Two -Way Siamese. Independent drop clapper valves. Plugs and chains available at extra cost. Specify lettering: "Standpipe" or "Auto-Spkr." Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plate. Specify size and thead: 21/2" x 21/2" x 4" 21/2" x 21/2" x 6" Elkhart 29 90° Three -Way Sidewalk Siamese. Cast brass with inde- pendent drop clapper valves. Plugs and chains available at extra cost. Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plated. Specify thread: 212"x21/"x21AY'x6` 10 A . 16 Description Mueller Co. G-1 Cap Nut Bronze ASTM B62 REV 3 97 Hand Wheel Cast Iron ASTM A[ 26 CL.B Catalog number --- R-2360-6 flanged ends Ll Sizes--- 2-1/2", 3", 4". 6", 8", 10", 12" MUELLER® 2360 SERIES OS&Y RESILIENT WEDGE GATE VALVE WITH FL. ENDS ❑ Meets or exceeds all applicable requirements of AWWA 0509, UL 262 and FM 1 120/1 130 specifications ❑ Flanged end dimensions and drilling comply with ANSI B 16.1 . class 125 ❑ Iron body with MUELLER@ Pro-GardTM Fusion Epoxy Coated interior and exterior surfaces ❑ Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and complies with NSF -61 ❑ Iron wedge, symmetrical & fully encapsulated with molded rubber; no exposed iron ❑ Outside Screw and Yoke (OS&Y)* ** ❑ Adjustable packing ❑ Handwheel ---open left or open right ❑ 2-1/2"-12" sizes --- AWWA: 250 prig (1723 kPa) maximum working pr-ssure 500 psig (3447 kPa) static test pressure; UL/FM: 200 psig (1379 kPa) maximum working pressure, 400 psig (2758 kPa) test pressure Options See pages 10.54 and 10.55 for more information on Resilient Wedge Gate Valve options ❑ ASTM 1398-C66IOOM04 stem ❑ Stainless steel fasteners: Type 304, Type 316 ❑ Test Plug G -t Resilient wedge gate valve parts = G-3 .,,� torr vin Catalog Part No. Description Material Material standard G-1 Cap Nut Bronze ASTM B62 G-3 Hand Wheel Cast Iron ASTM A[ 26 CL.B G-4_ Washer _ Bush Nut Brass G-.5__ Bronze ASTM 8584 G-7 _ Gland Nut Bronze ASTM B21 Alloy 464 , Packing Gland Ductile Iron ASTM A536 GR.65-45-12 G-10 •Gland Boll Steel ANSI 818.2.1 G -I I ** Yoke Bolt & Nut Steel ANSI B 18.2.1 G 16 — Bonnet Bolts & Nuts Carbon Steel ASTM A307 Grade B, Zinc Plated G-23 G-206 Stem Packin _ _ Guide Cap rings___ Lubricated Flax Celcon G-209 G-211 Wedge. Rubber Encapsulated Bonnet Gasket Cast Iron*** ASTM A 126 CL.B Rubber ASTM D2000 G-2112 B�od� Cast Iron ASTM A126 CL.6 fG-213 —1----- _G 214 * G-21-5 ** _ IStele Bonnet & Yoke µ[Bushing ' BBoonnet Bronze ASTM B138 Cast Iron ASTM A126 CL.B Cast Iron ASTM A 126 CL.B VG -216 ** I Yoke G-217 0 -rind G-118Disc Nut __....--- ---------------- G-219 1 Stem Nut Pin Cast Iron ASTM A126 CL.B Nitrile __ Bronze ASTM B62 ------ Stainless Steel _'-1/1... h,-.ize, have one-piece N111110& yoke. X" 1' aze. have .epnnne bonnel & yoke. -I ulk cii"psulated in molded ruhtxr uuh no iron exposed. SEF, PAGE 10.59 FOR ORDERING INSTRUCTIONS 3A G 216" G4 G-5 G-213 G7 GB G-10 G- Mom m G-23 G-214' G-215" G-16 G-211 G 217 G 2t8 G-212 G 219 G 209 G-206 July 19, 1999 Wet 26 a 1. PRODUCT NAME Viking Model J-1 Alarm Check Valve Available since 1993 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (616) 945-9501 (877)384-5464 Fax: (616) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION The Viking Model J-1 Alarm Check Valve serves as a check valve by trap- ping pressurized water above the clap- per and preventing reverse flow from sprinkler piping. The valve is designed to initiate an alarm during a sustained flowof water (such as the flow required by an open sprinkler) by operating an optional water motor alarm and/or alarm pressure switch. Ex- ternal by-pass trim serves to prevent un- wanted (false) alarms at lower flows. The Model J-1 Alarm Check Valve may be installed vertically or horizontally on wet -pipe sprinkler systems with con- stant pressure or variable pressure wa- ter supplies. The valve is made suitable for use on variable pressure water sup- plies by adding the optional retard chamber to the standard trim. The valve is available with a flanged inlet and flanged outlet, with a flanged inlet and grooved outlet, or with a grooved in- let and grooved outlet. 4. TECHNICAL DATA LISTINGS AND APPROVALS See Table 2 on this page. Form No. F_062293 Rated to 250 psi (1 724 kPa) water working pressure. Viking 250 psi (1 724 kPa) trim is required to maintain listings and approvals. Order 250 psi (1 724 kPa) trim separately. Trim charts are specific for vertical or hori- zontal installation. Refer to Viking Model J-1 Alarm Check Valve Trim Charts with the words "Maximum 250 psi water working nr Q,.re" in the title Factory tested hydrostatically to psi (3 447 kPa). Standard flanged connections: ANSI B16.42 Class 150 (Mates with ANSI Class 125 and Class 150 flanges). -____.............. Table 1 Size , Inlet I Outiet FrictionShippin4l Part Valve Type Type Loss* Weight I No. 3" 10 ft. 35 lbs. 80 mm) Flange Flange (3,1 m) (16 ka) , 08235 3 ! Flange Groove, 10 ft. 27 lbs. 108236 mm) I (3 1 m) (12 kg.) 1._.........._. mm) Groove'Groove (3 m) �9 9� 1 08237 Flange Flange I_. _{-- 23 4" � 13 ft. 47 lbs. 08238 ) mm): :(4.0 m) i (21 ka) —J (100 mm) F 500 ---- 4" r. Systems with water working pressures above 175 psi (1 207 kPa) may require extra -heavy pat- tern fittings. Model J-1 Alarm Valve flanges are Ductile Iron ANSI B16.42 Class 150 with a maximum water working pressure of 250 psi. ANSI 1316.42 Class 150 flanges are NOT compatible with ANSI Class 250 or Class 300 flanges. To mate the Model J-1 Alarm Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved-inlet/grooved- outlet style installed with listed grooved/flanged adapters of the appropriate pressure rating. For piping with grooved connections, the grooved -inlet and/or grooved - outlet Model J-1 Alarm Check Valve may be installed with listed grooved couplings of the appro- priate pressure rating. Standard Grooved connections: ANSI/AWWA C606 MATERIAL STANDARDS Refer to Figure 1 on page 26 e. 5-A. FEATURES 1. Ductile iron body for less weight and extra strength. 2. Rubber -faced clapper hinged to ac- cess cover for quick removal and easy servicing. All moving parts can be serviced without removing the valve from the installed position. 3. With the cover/clapper assembly re- moved, clapper rubber replacement requires removal of only one screw. 6" 13 ft. 1 37 lbs. 108239 1.0 m) I (17 ka) i 13 ft ( 27 lbs. rove Groove; 08240 (4.0 .m) . (12 kg)._. _.._ _........ nge Flange 20 ft. 75 lbs. 08241 (6.0 ml (34 ka) 6 Flange Groove: 20 ft. 64 lbs. 08242 (150 mm)._,.(6 0 m)1 (29 kg)._j..... ......... 6 Groove Groove; 20 ft. 51 lbs, ! 08243 (150mm) 6,0 m 23 k 8" 23 ft. 135 lbs. 200 mm, Flange Flange: 08244 ( ), _i X7,0 m(61�ck --- 8 FlangelGroovel 23 ft. 119 lbs. 08245 8"23 ft. 106 lbs. (200—), Groove Groove: (7 0 m) l (48 kg) 08246 *Expressed in equivalent length of Schedule 40 pipe based on Hazen & Williams formula: C =120. Viking Model J-1 Alarm Check Valves are available outside of North Amer- ica with flanges drilled according to European PN10 specifications or Table E specifications. Contact the manufacturer for availability. 4. External by-pass trim to minimize clapper movement and false alarm. 5. Trim allows installation of optional non -interruptible pressure switch to activate an electric alarm panel and/or remote alarm. 6. Can be installed on constant or vari- able pressure water supplies. 7. Can be installed vertically or horizon- tally. J-1 Alarm Check Valve ADDroval Chart UL1 C UL2 FM NYC3 Yes Yes Yes Yes 1 UL listed, Guide VPLX, Control No. 958A. 2 Listed by Underwriters Laboratories, Inc. for use in Canada. 3 Accepted for use, City of New York Departn of Buildings, MEA 89-92-E Vol. XI. Table 2 Replaces page 26 a -f, dated March 4, 1999 (Changed dimensions on chart in Figure 1 to reflect correct dimensions) Wet 26 b July 19, 1999 8. Valve housing tapped for inlet and outlet pressure gauges, alarm de- vices, and system main drain. 9. Trim includes alarm test valve for test- ing alarms without reducing system pressure. 5-B. ACCESSORIES The valve is listed and/or approved with specific trim for use up to 250 psi (1 724 kPa). No substitutions or omissions, in part or in full, are allowed. Additional ac- cessories to the standard trim packages are required for a complete system meeting the requirements of the applica- ble rules and codes. See appropriate technical data for additional information. TRIM PACKAGES 1. 250 psi (1 724 kPa) vertical trim* for use when the J-1 Alarm Check Valve is installed vertically. 2. 250 psi (1 724 kPa) horizontal trim* for use when the J-1 Alarm Check Valve is installed horizontally. For optional pre -trimmed Model J-1 Alarm check Valves, refer to the current Viking Price List schedule or contact the manu- facturer. Trim packages include: A. All necessary nipples and fittings B. All standard trim accessories C. Necessary gauges ORDER SEPARATELY A. Retard Chamber: The Viking Retard Chamber is re- quired when the J-1 Alarm Check Valve is installed on systems with a variable pressure water supply to minimize unwanted (false) alarms. B. Water Motor Alarm : The J-1 Alarm Check Valve is de- signed to operate a mechanical alarm during a sustained flow of wa- ter (such as the flow required by an open sprinkler). Refer to the water motor alarm technical data. C. Alarm Pressure Switch: The J-1 Alarm Check Valve trim al- lows installation of pressure switches to operate local electric alarms and/or remote electric alarms during a sustained flow of water (such as the flow required by an open sprinkler). Refer to alarm pressure switch tech- nical data. Additional accessories are available and may be required for operation or su- pervision. Refer to the system descrip- tion for complete operating trim require- ments. 6. AVAILABILITY AND SERVICE The Viking Model J-1 Alarm Check Valve and accessories are available through a network of domestic, Cana- dian, and international distributors. See the Yellow Pages of the telephone direc- tory for a local distributor (listed under "Sprinklers -Automatic -Fire") or contact The Viking Corporation. ........... ... ..._........................... ......___......................_......................... .......... ............... _._..__.. Viking technical data may be found on The Viking Corporation's Web site at http://www.vikingcorp.com. The Web site may include a more recent edition of this technical data page. 7. GUARANTEES For details of warranty, refer to Viking's current list price schedule or contact The Viking Corporation directly. 8. OPERATION (Refer to Figure 1 on page 26 e.) The Model J-1 Alarm Check Valve is manufactured with a hinged clapper (9) equipped with a torsion spring (6) to as- sure proper operation when the valve is installed in the horizontal position. Minor flows, resulting from small surges, travel around the clapper through exter- nal by-pass trim to minimize false alarms. Rubber gasket (10) forms a tight seal against brass water seat (13). This seal, and the check valve installed in the external by-pass trim, serve to trap higher pressurized water in the sprinkler piping and prevent reverse flow. During a sustained flow of water, such as the flow required by an open sprin- kler, hinged clapper (9) moves off seat (13) to the open position. Water flows through orifices in grooved seat (13), and enters the alarm port to activate alarm devices connected to the system. Operation with Retard Chamber: When the optional retarding chamber is used, water entering the grooved seat alarm port is directed into the retarding chamber. Temporary pressure surges or fluctuations, large enough to move the valve clapper, are automatically drained through the restricted drain. During a sustained flow of water, such as the flow required by an open sprin- kler, the clapper will be held off its seat. The retarding chamber will fill faster than water can drain through the restricted drain of the alarm valve trim. Alarm de- vices will be pressurized. Refer to tech- nical data describing the Viking Re- tarding Chamber and alarm devices. 9. INSTALLATION For proper operation and approval, the valve must be trimmed in accordance with Viking Model J-1 Alarm Check Valve Trim Charts for use on systems with water working pressure up to 250 psi (1 724 kPa). Trim charts are specific for vertical or horizontal installation, and they include the words "Maximum 250 psi water working pressure" in the title. The optional Viking Retarding Chamber is required when used on variable pres- sure water supplies. Systems with water working pressures above 175 psi (1 207 kPa) may require extra -heavy pattern fittings. The Model J-1 Alarm Check Valve flanges are Duc- tile Iron ANSI B16.42 Class 150 with a maximum water working pressure of 250 psi. ANSI 616.42 Class 150 flanges are NOT compatible with ANSI Class 250 or Class 300 flanges. To mate the Model J-1 Alarm Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved-inlet/grooved-outlet style in- stalled with listed grooved/flanged adapters of the appropriate pressure rating. To mate to piping with grooved connections, the grooved -inlet and/or grooved -outlet Model J-1 Alarm Check Valve may be installed with listed grooved couplings of the appropriate pressure rating. The Model J-1 Alarm Check Valve must be installed in an area not subject to freezing temperatures or physical dam- age. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compatibility with the Model J-1 Alarm Check Valve, trim, and associ- ated equipment. Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter is present. The Model J-1 Alarm Check Valve may be installed in the vertical position with direction of flow up, or in the horizontal position with the access cover up. 1. Verify that the appropriate trim chart and technical data for the Alarm Check Valve and associated equip- ment are available. 2. Remove all plastic thread protectors from the openings of the Alarm Check Valve. July 19, 1999 NIKING` 3. Apply a small amount of pipe -joint compound or tape to the external threads of all pipe connections re- quired. Take care not to allow any compound, tape, or other foreign matter inside any nipples or openings of the valve or trim components. 4. Install the Model J-1 Alarm Check Valve and trim according to current Viking Trim Charts for the valve used. Trim charts are provided with trim package and the Viking En- gineering and Design Data book. 5. Verify that all system components are rated for the water working pressure of the system. Hydrostatic Test: The Model J-1 Alarm Check Valve is manufactured and listed for use at a maximum water working pressure of 250 psi (1 724 kPa). The valve is factory tested at 500 psi (3 447 kPa). The valve may be hydrostatically tested at 300 psi (2 069 kPa) and/or 50 psi (345 kPa) above the normal water working pres- sure, for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. If air testing is required, do not exceed 40 psi (276 kPa) air pressure. 10. PLACING THE SYSTEM IN SERVICE When the wet -pipe system is ready to be placed in service, verify that all equip- ment is adequately heated and pro- tected to prevent freezing and physical damage. Note: For proper operation of the wet system and to minimize unwanted (false) alarms, it is important to remove trapped air from the system when filling it with water. Air trapped in the system may also cause intermittent operation of the water motor alarm during a sus- tained flow of water (such as the flow re- quired by an open sprinkler or the sys- tem test valve). Consider installation of auxiliary vents to facilitate venting. Caution: Opening of the water supply main control valve will result in water flow from any openings in the system. 1. Verify that auxiliary drains are closed and that the system is free of leaks. 2. Open the system test valve (and any auxiliary vents provided to facilitate removal of air from the system) to al- low air to escape from the system while it is filling with water. 3. If desired, close the alarm shut-off valve to prevent local alarms from op- erating while filling the system. Note: Alarms and electric panels controlled by an alarm pressure switch installed in the "electric alarm panel" connection provided in the trim cannot be interrupted. (See trim chart.) 4. Slowly open the water supply main control valve. 5. Allow the system to completely fill with water. Allow water to flow from the system test valve, and any other open vents provided, until all air is ex- hausted from the system. 6. After all air is exhausted from the sys- tem, close the system test valve and all other open vents. 7. The pressure gauge on the system side of the Alarm Check Valve Clap- per should indicate water pressure equal to or greater than the water pressure indicated on the gauge lo- cated on the supply side of the clap- per. 8.OPEN the Alarm Shut -Off Valve in the Alarm Valve trim, and verify that all other valves are in their normal oper- ating position. 9. Secure all valves in their normal oper- ating position. 10. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the affected area that the system is in service. 11. INSPECTIONS and TESTS NOTICE: The owner is responsible for maintaining the fire -protection system and devices in proper operating condi- tion. The Viking Model J-1 Alarm Check Valve and trim must be kept free of for- eign matter, freezing conditions, corro- sive atmospheres, contaminated water supplies, and any condition that could impair its operation or damage the de- vice. It is imperative that the system be in- spected and tested on a regular basis. The frequency of the inspections may vary due to contaminated water sup- plies, corrosive water supplies, and cor- rosive atmospheres. For minimum maintenance and inspection require- ments, refer to the National Fire Protec- tion Association's pamphlet that de- scribes care and maintenance of sprin- Wet 26 c MODEL J-1 ALARM CHECK VALVE kler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection re- quirements that must be followed. WARNING: Any system maintenance which involves placing a control valve or detection system out of service may eliminate the fire -protection capabilities of that system. Prior to proceeding, no- tify all the Authority Having Jurisdiction. Consideration should be given to em- ployment of a fire patrol in the affected areas. 11-A. INSPECTION Monthly visual external inspection of Alarm Check Valves is recommended. 1. Verify that pressure gauges indicate normal water supply pressures. It is normal for the gauge on the system side of the clapper to register a. higher pressure than the gauge on the supply side of the clapper be- cause pressure surges are trapped above the clapper. 2. Check for signs of mechanical dam- age and/or corrosive activity. If de- tected, perform maintenance as re- quired or, if necessary, replace the device. 3. Verify that valve and trim are ade- quately heated and protected from. freezing and physical damage. 4. When equipped with variable pres- sure trim, verify that there is no un- wanted leakage from the restricted drain of the retard chamber. It is nor- mal for drainage to occur during pressure surges that exceed the ca- pacity allowed through the by-pass trim. 5. Verify that the water supply main con- trol valve is open, and that all valves are in their normal operating position and appropriately secured. 11-B. QUARTERLY TESTS 11-113.1 Water Flow Alarm Test Quarterly testing of water flow alarms is recommended and may be required by the Authority Having Jurisdiction. 1. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the area affected by the test. Note: An alarm shut-off valve is pro- vided to silence local alarms. No shut-off valve is provided for the pressure switch connection intended Wet 26 d NIKING` to activate electric alarm panels. (Re- fer to J-1 Alarm Check Valve Trim Chart.) 2. Fully open the main drain (on the Alarm Check Valve Trim) to flush away any accumulation of foreign material. Consider performance of quarterly main drain test (Refer to paragraph 11-6.2 MAIN DRAIN TEST). 3. Close the main drain. 4. To test electric alarms (if provided) and/or mechanical water motor gong (if provided), OPEN the system test valve. If freezing weather or other conditions prohibit use of the system test valve, OPEN the alarm test valve in the alarm check valve trim. Note: Use of the alarm test valve al- lows testing of alarms without reduc- ing the system pressure. A. Electric alarm pressure switches should activate. B. Electric local alarms should be au- dible. C. The local water motor alarm should be audible. Note: When using the system test valve for the water flow alarm test, intermittent operation of the water motor alarm may indicate air is trapped in the system (refer to paragraph 10: PLACING THE SYSTEM IN SERVICE). D. Verify that remote station alarm signals (if provided) were re- ceived. 5. When testing is complete, close the test valve used. 6. Verify: A. All local alarms stop sounding and electric panels (if provided) reset. B. All remote station alarms reset. C. Retard chamber and water motor alarm supply piping has drained properly. 7. Verify that the alarm shut-off valve in the Alarm Check Valve trim is OPEN, the alarm test valve is CLOSED, and all valves are in their normal operat- ing position and appropriately se- cured. 8. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the affected area that testing is complete. 11-B.2 Main Drain Test Quarterly performance of the Main Drain Test is recommended and may be re- quired by the authority having jurisdic- tion to verify integrity of the water sup- ply. 1. Notify the authority having jurisdic- tion, remote station alarm monitors, and those in the area affected by the test. 2. Perform monthly visual inspection. Refer to paragraph 11A INSPEC- TION. 3. Verify that adequate drainage is pro- vided for full flow from Main Drain outlet. 4. Record pressure reading from the wa- ter supply pressure gauge. 5. Fully OPEN the main drain located on the Alarm Check Valve. 6. When a full flow is developed from the main drain, record the residual pres- sure from the water supply pressure gauge. 7. When the test is complete, SLOWLY CLOSE the main drain. 8. Compare test results with previous flow information. If deterioration of the water supply is detected, take ap- propriate steps to restore adequate water supply. 9. Verify that normal water supply pres- sure has been restored, and that all alarm devices and valves are se- cured in normal operating position. 10. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the area affected by the test that the test is complete. Record and/or provide notification of test re- sults as required by the Authority Having Jurisdiction. 11-6.3 Five -Year Internal Inspection Internal inspection of Alarm Check Valves is recommended every five years unless inspections and tests indi- cate more frequent internal inspections are required. Refer to Figure 1 on page 26 e. 1. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the area affected that the system will be taken out of ser- vice. Consideration should be given to employment of a fire patrol in the affected areas. 2. Close the water supply Main Control Valve, placing the system out of ser- vice. July 19, 1999 MODEL J-1 ALARM CHECK VALVE 3. Open the main drain. If necessary, open the system test valve to vent and completely drain the system. 4. Use appropriate wrench to loosen and remove cover screws (15), and re- move Cover/Clapper assembly (2-12). 5. Inspect water seat (13). Wipe away all contaminants, dirt, and mineral deposits. Clean any orifices in the seat that are restricted or plugged by mineral deposits. Do not use sol- vents or abrasives. 6. Inspect cover/clapper assembly (2-12) and cover gasket (14). Test hinged clapper (9) for freedom of movement and spring (6) for tension retention. A. Spring (6) tension should engage when the top of hinged clapper (9) is moved from perpendicular to cover (2) toward the open (flow) position. Renew or replace damaged or worn parts as required. Caution: NEVER apply any lubricant to seats, gaskets, or any internal operating parts of the valve. Petroleum-based grease or oil will damage rubber compo- nents and may prevent proper opera- tion. 7. When internal inspection of the alarm check valve is complete, perform step 6 of paragraph 12: ALARM CHECK VALVE MAINTENANCE to re -install Cover/Clapper Assembly (2-12). 8. Place the wet system back in service, Refer to paragraph 10: PLACING THE SYSTEM IN SERVICE, No.10). 12. ALARM CHECK VALVE MAINTENANCE ( Refer to Figure 1 on page 26 e.) 1. Perform steps 1 through 6 of para- graph 11-13.3 FIVE-YEAR INTER- NAL INSPECTION. 2. To remove clapper rubber (10): A. Use the appropriate wrench to loosen and remove the but- ton -head socket screw (12), hex nut (7), sealing washer (8), and rubber retainer (11). B. Remove the clapper rubber (10) for inspection. If the clapper rub- ber shows signs of wear such as cracking, cuts, or excessively deep grooves where the rubber (continued on page 26 0 July 19, 1999 FNIKJNG B C l.._. _.._.._..� _.._. J E — (200 m) NPT I \ LOW P s_' +yasner 9 t0 A oocotia - — II olvt5 i Wet 26 e MODEL J-1 ALARM CHECK VALVE SIZE A B C D E F' G•• 3^ (80mm) 10-1/8" (257) 4-3/4" (120,7) 2-3/4" (69,9) 1-13/16" (46) 2-1/8" (54) 7_7/8 (200) 3/a" (19,05) 4 (100mm) tD-5/8" (269,9) 5-3/16" (131,8) 3-1/8'. (79,4) 1-7/8'. (47,6) 2-1/4" (57,2) 9" (228,6) 15/16'. (23.81) 6" (150mm) 13-3/8" (340) 6-3/4' (171,5) 4-1/8" (104,8) 1 47 8' (51 4 (211 (25.a) (200mm) (431,8) (225.4) (127) (57 2) (73 0) 1(342/9) (28 58) trx v •i 13 Dimensions shown in parentheses are millimeter. 4 11 • Flanges ore optional. }�4" Volve is available Fig X Fig, Fig X Grv, or Gry X Grv. (20 mm) NPT ' • ore manufactured with sculptured tlonges. 4', 6", and 8" valves 3 i 7 D Dimension indicates thickness of (longe at boll holes. _._.._.._.._J: Figure 1 F* ' Model J-1 Alarm Check Valve Item) Part Numbers No.._13" (8o mm) 4 000..mm) 8 ..(1.50 mm) 2 i 09922 09923 09924 1 3 0.4991A 4_ _l 05355A 049.0.0 _ _ 5 1.05445A 05445A _ 05445A 6._ 06021.6 059396 0.,5940.6....._ 7 I`I ----- -" • 8 I • Description Material 8.' (20 mm _ Ductile Iron ASTM A536 Bod E -Coated HSLA Steel, A715 and 09925 Cover Assembly Stainless Steel—UNS S30400 Bushing Lubricoma 189 Ryton 05334..A.- Cla er_Hin a Pin Starnless Steel, UNS S304..00 -Clapper. g.-- 05369A H1n9e Pin Retaining Rina Stainless Steel UNS S15700 _.. 059526. Spring _...; Stainless Steel ,.U.NS S3.0..200 Clapper Hex Nut 318 -16 UNC ___. Stainless Steel UNS S30400 _._. • Clapper He..x_Nut'/z .13._UNC ...__ Stainless Steel _UNS S30400 Sealin Washer 3/8" x 1" O.D. EPDM and Stainless Steel — _ Sean Washer'/z' x 1-118" O.D. EPDM and Stainless Steel 1 2 1 2 1 0 1 1. 1 2 1.... 2 1._ 0... 1 1 1 2 0 1 2 2 0 0 1 1 ; 0 0 . 0 0 1 1 1 - Clap Teflon.®Coated_H...R Steel UNS G101801 11 1 1 9 _.. Nod 08070 __ 08072 08073 __ 08075 Clapper Rubber EPDM Stainless Steel.,_UNS S30..400 1!1 1 1i _ 11 I 0807-1 07659 08074,.-....._ 08076_ C..11a.p.per Ru.b..ber Reta.. ner l Screw Button Head, Socket Stainless Steel, UNS S30400 �I ' • -- - ---l 318"-24 UNF_x'/z (1_2.,7_mm) Ig.__. __. _ 0 - Screw Button Head, Socket Stainless Steel, UNS-S30400 1 0 0 1 12 10308 /z. 2..0_ UNF x.3/8 (19,O.mm) Ig Screw Button Head, Socket Stainless Steel UNS S30400 0 0 0 1 10686 yZ___20 UNF x 7/8 (22,_2.. mm) Ig._ - - 111.. 1 -- - -- - Brass _UNS C84400 Seat. _ - 13. - 1.. 053546 04.6.498 ! 04992B 05339C Cover Gasket. SBR ._u er ._._ -- 0 0 %1 H H.0 Screw Steel, Zinc Plated 4 6 01517A 01517A 3/8"-16 UNC. x 3147-(19.0_mm)..I.g , - -- - . ..- H.H.C.Screw Steel, Zinc Plated 0 0 6 0 15 04993A ....___....._ 13 UNC._x.,7 H H.C. Screw Plated - Steel, Zinc 01922A 518"-11 UNC x1 1l4" (31 8mm) Ig�_— -- ---- ___ Indicates part is not available from The Viking Corporation. ' Indicates part is available in a Sub -Assembly only --see Sub Assembly list SUB_ASS-EMBLIES AVAILABLE Item Sub A..ssembly .Part Numbers _ .. Sub -Assembly Name ..__ Nos _ 3_' 4--- 2 12 09918 09919 09920 09921 Cover/ClaQpPr Assembly ---- ---- 3, Clapper Assembly 08518 ! 08519 08520 1 08521 pp Y _..._ . 7-12{ 7. I , 08522 ! 08523 08524 I 08525 Clapper Rubber Kit 1718 2 .718 j 08735 08735 08736 ! 10309 Clapper Screw, Sealing Washer, Nut Assembly 12 3� Wet 26 f July 19, 1999 contacts the water seat, replace the rubber. 3. To re -install clapper rubber (10): A. Place clapper rubber (10) overthe center hub of the rubber retainer (11). B. Position the retainer (11) (with rub- ber in place) against clapper (9) as shown in Figure 1. C. Replace and tighten the but- ton -head socket screw (12), seal- ing washer (8), and hex nut (7), as shown in Figure 1. Do not over - tighten. 4. To remove clapper (9), spring (6), and/or hinge pin (4): A. Remove hinge pin retaining rings (5), to free the hinge pin (4) for re- moval. After the hinge pin (4) is re- moved, the clapper (9) and spring (6) can be removed. 5. To re -install clapper (9), spring (6), and/or hinge pin (4): A. Verify that the clapper rubber (10) is in good condition and that it is properly installed. B. Position the clapper (9) with the elongated hinge holes aligned be- tween the holes of the hinge bracket welded inside cover (2). The system (top) side of the clap- per (9) must face the direction indi- cated by the flow arrow stamped inside the cover (2). C. Insert the hinge pin (4) through the holes at one end of the hinge as- sembly. Before continuing, re -install the spring (6), using care to orient the spring as shown in Figure 1. Continue to push the hinge pin (4) through the holes at the remaining end of the hinge as- sembly. D. Re -install the hinge pin retaining rings (5). 6. To re -install cover/clapper assem- bly (2-12): A. Verify that the cover gasket (14) is in position and that it is in good condition. B. Slide the cover/clapper assembly (2-12) into the Alarm Valve so that Replaces page 26 a -f, dated March 4, 1999 (Changed dimensions on chart in Figure 1 to reflect correct dimensions) the clapper rubber (10) contacts the grooved water seat (13). C. Replace cover screws (15). Use the appropriate wrench to evenly cross -tighten all screws to the torque values listed in Table 2 for the valve used. Do not over -tighten. Table 2 Torque Values for Model J-1 Alarm Valve Cover Screws Valve Size Screw Size Torque Values 3" (80 mm) 3/8" - 16 H.H.0 f 19 ft. lbs. _ 2,63 kg m 4" (100 mm) 3/8" - 16 H.H.0 19 ft. lbs. 2.63 kq m 6" (150 mm) ''/z" - 13 H.H.0 j 45 ft. lbs. 6,23 k9..m_.... 8" (200 mm) 5/8 - 11 H.H.093 ft. lbs. 12,9 kg m 7. To place the wet system back in service, refer to paragraph 10: PLACING THE SYSTEM IN SER- VICE. Form No. F 062293