Loading...
HomeMy WebLinkAbout2251 W P Ball BlvdPermit # Job Address: _ 2 2 s / (Al - CITY OF SANFORD PERMIT APPLICATION Date: vL c v -p Description of Work: /'Z S —2--7 Historic District: Zoning: Value of Work: $ Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm t/ Pool Electrical: New Service – # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair – Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: (Attach Proof of Ownership & Legal DescripEiou) . Owners Name &Add/rens: 114712;7 t 72- –�� l?C _.t '` _f.J,� ra. P.n nem_ c' S � 7 d Contractor Name &Address: L rr', � St to I'icense Nlrritbe Phone & `1 V % - �) (, _ 4 (�- Cj Contact Person: 22 rJ pp Phone: Lf % — S 6" D 3 7 Bonding Company: _ — Address: OCT U V .4. Mortgage Lender Address:^ i a Architect/Engineer:' t Phone: Address: % 1 d Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand of ;Ht a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT ITS YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be Yll public records of this county, and there may be additional permits required from other governmental entities such as water management districts stator federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of �yida j ien Law?�7}3. Signature of Owner/Agent Print Owner/Agent's Name Signature of Notary -State of Florida Owner/Agent is _ Personally Known to Me or _ Produced ID Date Date of Date Print ctor/Agent's Nam / 4 ' l Li'l fo/O f/ Signah,re of Notary -State of Florida 1 Date - Contractor/Agent is �rsonally Known to Mevr APPLICATION APPROVED BY: Bldg L) a7 Zoning: (Initial &Date) (Initial & Date) Special Conditions: Utilities: (Initial & Date) FD:Q ( jgg[ &Date) p LINDA L. PHILLIPS Notary Public, State of Florida My comm. exp. Sept. 29, 2006 Comm. No. DD 154192 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: 01 O PERMIT #: Q(l Q BUSINESS NAME / PROJECT: — Cn��R4 oo ADDRES�i>�J '/. 1. N , P. R& I 1 2 /Utj PHONE NCC O�� •9r3R7_ FAX NO.-rVg7 CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW F. A. [ ] F. S. ( HOOD [ ] PAINT BOOTH [) BURN PEWIT (, TENT PERMIT,[ ] TANK PERMIT [) OTHER [�( r ,1 ' TOTAL FEES: $ (PER UNIT SEE/BELOW) 77P� ,44t^j,,�— Address / Bldg. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that 1 will comply with all applicable codes and ordinances of the City of Sanford, Florida Sanford Fire Preven ion Divis Applicant's Signature Job Name Building Location System Contract Data File g _ _ _ Fire Protection by Computer Design EAGLE FIRE PROTECTION INC. 1205 CROWN PARK CIRCLE WINTER GARDEN FLORIDA 34787 407 656-8387 COST PLUS SANFORD NEW SEMINOLE TOWNE CENTER 1 04-55 04-55. W X2 JAMES M. CURTIS. P.E. 8801 Hunters Lake Drive Suite # 221 Tampa, FL 33647 Certificate # 37912 i=............. PLANS REVIEWED CITY OF SANFORD OCT Z 1 004 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 EAGLE FIRE PROTECTION INC. Page 1 COST PLUS SANFORD Date Hydraulic Design Information Sheet Name - COST PLUS SANFORD Date - 9/28/04 Location - SEMINOLE TOWNE CENTER Building - NEW System No. - 1 Contractor - YOUNG CONTRACTING CO., INC. Contract No. - 04-55 Calculated By - FRANK EDWARDS Drawing No. - 1 Construction: ( ) Combustible (X) Non -Combustible Ceiling Height - EXPOSED Occupancy - RETAIL STORE S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .2 (X) Wet Make VIKING D Area Per Sprinkler - 123.5 ( ) Dry Model M E Elevation at Highest Outlet - 23 ( ) Deluge Size 1/2 S Hose Allowance - Inside - 100 ( ) Preaction K -Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 150 N Note Calculation Flow Required - 431.02 Press Required - 31.143 At BOR Summary C -Factor Used: 120 Overhead 150 Underground W A T E R S U P P L Y C 0 M M S R T A 0 C R K A G E Water Flow Test: Pump Data: Date of Test - JANUARY 04 Time of Test - Rated Cap. - Static Press - 52 @ Press - Residual Press - 45 Elev. - 2 Flow - 2040 Elevation - 2 Location - SEE SITE PLAN Source of Information - CITY OF SANFORD UTILITIES Commodity Storage Ht. Storage Method: ( ) Single Row ( ) Double Row ( ) Mult. Row Class Area Solid Piled % ( ) Conven. Pallet ( ) Slave Pallet Flue Spacing Longitudinal Horizontal Barriers Provided. Tank or Reservoir: Cap. - Elev.- Well Proof Flow Location Aisle W. Palletized % Rack ( ) Auto. Storage ( ) Encap. ( ) Solid Shelf ( ) Non ( ) Open Shelf C—learance------ --:--St - orage --- --to--- -Ce-- __iling-- - _ Transverse Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Page 2 Date City Water Supply: C1 - Static Pressure 52 PSI C2 - Residual Pressure: 45 PSI C2 - Residual Flow 2040 GPM 150 140 130 P 120 R 110 D1 - Elevation 9.095 PSI D2 - System Flow 531.02 GPM D2 - System Pressure 42.512 PSI Hose (Adj City) GPM Hose ( Demand) 150 GPM D3 - System Demand 681.02 GPM Safety Margin 8.569 PSI E 100 S 90 S 80 U 70 R 60 C1 E 50 40 D2 3 30 20 10 D1 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (N^1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Fitting Legend Abbrev. Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow O PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date Fittings Summary EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Unadjusted Fittings Table 1 1/2 2 1/2 3/4 1 A B 21.5 9.0 17.0 C 1.0 1.0 1.0 D 12.0 1.0 E 2.0 2.0 2.0 F 1.0 1.0 1.0 G 9.5 17.0 D E H 3.0 4.0 1.0 1 7.0 8.0 2.0 J 2.0 2.0 4.5 K 3.0 4.0 13.0 L 1.0 1.0 2.0 M 2.0 2.0 2.0 N 7.0 7.0 7.0 0 3.0 3.0 5.0 P 1.0 1.0 1.0 Q 8.0 8.5 10.8 R 1.0 1.0 1.0 S 4.0 5.0 5.0 T 3.0 4.0 5.0 U 4.0 5.0 5.0 V 3.0 3.0 4.0 W 6.0 6.0 8.0 X 9.0 11.0 12.0 Y 2.0 4.0 5.0 Z 2.0 2.0 2.0 Page 4 Date 1 1/4 1 1/2 2 21/2 3 7.7 21.5 9.0 17.0 12.0 19.0 21.0 7.0 10.0 12.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 9.5 17.0 D E 28.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 13.0 17.0 1.0 1.0 1.0 1.0 2.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 3.0 4.0 3.5 6.0 5.0 8.0 7.0 6.0 8.0 8.5 10.8 13.0 17.0 16.0 1 8.5 10.0 13.0 14.0 20.0 14.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 8.0 9.0 11.0 12.0 13.0 45.0 16.0 18.0 6.0 8.0 10.0 12.0 15.0 M 10.0 2.0 2.0 2.0 3.0 4.0 18.0 29.0 35.0 1.0 1.0 1.0 2.0 2.0 O 7.0 9.0 11.0 14.0 16.0 19.0 22.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 1.8 2.2 2.6 3.4 Q 3.5 4.3 5.0 6.8 R S 27.0 10.3 45.0 55.0 8.5 10.8 13.0 98.0 16.0 6.0 8.0 10.5 12.5 15.5 50.0 22.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D E 12.0 47.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 F 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 H 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 1 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 K L 8.0 36.0 9.0 55.0 13.0 45.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N O P Q 33.0 R S 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 U 4.2 5.0 5.0 V 8.5 10.0 13.0 W 13.1 31.8 35.8 27.4 X 21.0 25.0 33.0 Y Z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Eagle Fire Protection Inc. COST PLUS SANFORD Date 9/28/04 Peaking Summary - GRIDSYSTEM ONLY Page Flow Pressure Pressure Required Required Differential SHIFT LEFT 430.28 30.811 -0.332 AREA CALCULATED 431.02 31.143 0.000 SHIFT RIGHT 410.34 30.455 -0.688 Pressure / Flow Summary - STANDARD EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Node No. 1 100 101 102 103 104 105 3 106 107 108 109 110 111 5 112 113 114 115 116 7 9 11 13 15 17 19 21 23 25 27 29 2 4 6 8 10 12 14 16 18 20 22 24 TOR BOR U1 U2 U4 U3 BK TEST Elevation K -Fact Press 23.0 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 7.0 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 115 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 8.1 23.0 115 23.0 .20 23.0 7.0 23.0 123.5 23.0 .20 23.0 7.0 23.0 123.5 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 Pt Pn Flow Actual Actual 14.11 10.08 9.38 9.3 9.3 9.4 9.82 14.13 10.09 9.39 9.32 9.31 9.42 9.84 14.22 10.44 10.31 10.28 10.33 10.65 14.37 14.5 14.61 14.69 14.75 14.8 14.82 14.83 14.84 14.84 14.84 14.84 15.6 15.62 15.68 15.81 15.96 16.14 16.36 16.6 16.89 17.22 17.5 17.85 19.41 31.14 32.01 34.03 32.06 34.24 42.31 42.51 n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n 25.71 24.81 24.71 24.7 24.84 25.39 25.73 24.82 24.72 24.72 24.86 25.4 26.17 26.01 25.97 26.03 26.43 100.0 150.0 The maximum velocity is 11.01 and it occurs in the pipe between nodes 3 and 106 Page 5 Date Density Area Press Req. .2 123.5 7.0 .2 115 7.0 .2 115 7.0 .2 123.5 7.0 .2 123.5 7.0 .2 123.5 7.0 .2 123.5 7.0 .2 115 7.0 .2 115 7.0 .2 123.5 7.0 .2 123.5 7.0 .2 123.5 7.0 .20 115 7.0 .20 115 7.0 .20 123.5 7.0 .20 123.5 7.0 .2 123.5 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Standard EAGLE FIRE PROTECTION INC. Page 6 COST PLUS SANFORD Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *****' * Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 -80.39 1.728 IT 11.290 15.583 14.111 to 69.76 120 11.290 0.0 K Factor= 17.66 100 -80.39 -0.1501 26.873 -4.034 Vel = 10.998 100 25.72 1.728 9.500 10.077 K Factor = 8.10 to -80.47 120 0.0 0.0 Vel = 11.009 101 -54.67 -0.0736 9.500 -0.699 Vel = 7.479 101 24.80 1.728 3.083 9.378 K Factor = 8.10 to -54.74 120 0.0 0.0 Vel = 7.489 102 -29.87 -0.0240 3.083 -0.074 Vel = 4.086 102 24.71 1.728 5.667 9.304 K Factor = 8.10 to -29.91 120 0.0 0.0 Vel = 4.092 103 -5.16 -0.0009 5.667 -0.005 Vel = 0.706 103 24.70 1.728 9.500 9.299 K Factor = 8.10 to -5.19 120 0.0 0.0 Vel = 0.710 104 19.54 0.0109 9.500 0.104 Vel = 2.673 104 24.84 1.728 8.375 9.403 K Factor = 8.10 to 19.53 120 0.0 0.0 Vel = 2.672 105 44.38 0.0500 8.375 0.419 Vel = 6.071 105 25.38 1.728 IT 11.290 38.750 9.822 K Factor = 8.10 to 44.39 120 11.290 0.0 Vel = 6.073 2 69.76 0.1155 50.040 5.778 Vel = 9.544 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 0.0 69.76 15.600 K Factor= 17.66 3 -80.47 1.728 IT 11.290 15.583 14.134 to 120 11.290 0.0 106 -80.47 -0.1504 26.873 -4.042 Vel = 11.009 106 25.73 1.728 9.500 10.092 K Factor = 8.10 to 120 0.0 0.0 107 -54.74 -0.0737 9.500 -0.700 Vel = 7.489 107 24.83 1.728 3.083 9.392 _ K Factor = 8.10 to 120 0.0 0.0 108 -29.91 -0.0240 3.083 -0.074 Vel = 4.092 108 24.72 1.728 5.667 9.318 K Factor = 8.10 to 120 0.0 0.0 109 -5.19 -0.0009 5.667 -0.005 Vel = 0.710 109 24.72 1.728 9.500 9.312 K Factor = 8.10 to 120 0.0 0.0 110 19.53 0.0109 9.500 0.104 Vel = 2.672 110 24.86 1.728 _ 8.375 9.416 _ K Factor = 8.10 to 120 0.0 0.0 111 44.39 0.0500 8.375 0.419 Vel = 6.073 111 25.40 1.728 IT 11.290 38.750 9.835 K Factor = 8.10 to 120 11.290 0.0 4 69.79 0.1156 50.040 5.783 Vel = 9.548 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard EAGLE FIRE PROTECTION INC. 21.18 0.0127 112.997 Page 7 COST PLUS SANFORD 0.0 22.580 Date Hyd. Qa Dia. Fitting Pipe Pt Pt 15.809 Ref. 9 "C" or Ftng's Pe Pv "***"* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 10 21.37 69.79 112.997 1.462 Vel = 2.924 15.618 K Factor= 17.66 5 -65.86 1.728 1T 11.290 25.083 14.216 to 15.962 _ 120 11.290 0.0 24.28 1_12_ -65.86 -0.1038 to 36.373 -3.776 Vel__ 9.010 112 26.17 1.728 0.0164 3.083 10.440 K Factor = 8.10 to 120 0.0 0.0 113 -39.69 -0.0405 _3.083 -0.125 Vel = 5.430 _ 113 26.02 1.728 5.667 10.314 K Factor = 8.10 to 120 0.0 0.0 114-13.67 -0.0056 5.667 -0.032 _ Vel = 1.870 _ _ __.. - .----------- 114 25.97 25.97 1.728 9.500 10.282 K Factor = 8.10 to 120 0.0 0.0 115 12.3 0.0046 9.500 0.044 Vel = 1.683 _ - 115 26.03 1.728 8.375 10.326 K Factor = 8.10 to 120 0.0 0.0 116 38.33 0.0381 8.375 0.319 Vel = 5.244 116 26.43 1.728 1 T 11.290 38.750 10.646 K Factor = 8.10 to 120 11.290 0.0 6 64.76 0.1006 50.040 5.036 Vel = 8.859 0.0 6_4.76 15.682 K Factor= 16.35 7 21.18 1.728 2T 11.290 90.417 14.371 to 120 22.580 0.0 8 21.18 0.0127 112.997 1.438 _ -Vel = 2.898 0.0 22.580 0.0 12 - 21.96 0.0136 21.18 1.538 15.809 K Factor= 5.33 9 21.37 1.728 2T 11.290 90.417 14.500 to 13 120 22.580 0.0 14.689 10 21.37 0.0129 112.997 1.462 Vel = 2.924 22.94 0.0 112.997 1.667 0.0 21.37 15.962 _ K Factor = 5.35 11 21.96 1.728 2T 11.290 90.417 14.606 to 120 22.580 0.0 12 - 21.96 0.0136 112.997 1.538 0.0 21.96------ 13 22.94 1.728 2T 11.290 90.417 14.689 to 120 22.580 0.0 14 22.94 0.0148 112.997 1.667 0.0 22 94 16.356 15 24.28 1.728 2T 11.290 90.417 14.752 to 120 22.580 0.0 16 24.28 0.0164 112.997 1.852 0.0 Vel = 3.004 K Factor = 5.47 Vel = 3.138 K Factor= 5.67 Vel = 3.322 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Page 8 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11C11 or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 16.604 K Factor -=- 5.9.6 -- --- - - - - 14.796 0.0 2.093 Vel = 3.549 16.889 K Factor= 6.31 14.824 2 4.2 8 0.0 2T 11.290 90.417 2.398 Vel = 3.820 17 25.94 1.728 2T 11.290 90.417 to 0.0 120 Vel = 4.044 0.0 0.0 22.580 18 25.94 0.0185 7 0.0 112.997 3.012 0.0 17.849 K Factor= 7.47 24.798 K Factor= 0 1 25.94 4.31 13.000 14.111 9 19 27.92 1.728 2T 11.290 90.417 to 80.39 120 13.000 0.023 22.580 20 27.92 0.0212 13.000 14.134 112.997 to 0.0 120 0.0 0.0 13.000 5 27.92 0.0063 13.000 0.082 Vel = 3.537 21 29.56 1.728 2T 11.290 90.417 to 0.0 120 22.580 22 29.56 0.0236 0.083 Vel = 112.997 13 0.0 4.31 13.000 14.689 29.56 120 0.0 0.0 23 31.58 1.728 2T 11.290 90.417 to Vel = 120 22.580 24 31.58 0.0267 112.997 0.0 31.58 16.604 K Factor -=- 5.9.6 -- --- - - - - 14.796 0.0 2.093 Vel = 3.549 16.889 K Factor= 6.31 14.824 0.0 0.0 2T 11.290 90.417 2.398 Vel = 3.820 to to 17.222 K Factor= 6.73 14.834 0.0 0.0 0.0 2.665 Vel = 4.044 0.0 0.0 Vel = 0 17.499 K Factor= 7.07 14.837 7 0.0 4.31 3.012 Vel = 4.320 17.849 K Factor= 7.47 25 0.0 1.728 2T 11.290 90.417 14.837 0.0 to to 120 22.580 9.961 0.0 0.0 0.0 0.0 112.997 0.0 0.0 Vel = 0 -2-6- 0.0 4.986 7 -21.18 4.31 13.000 0.0 24.798 K Factor= 0 1 80.39 4.31 13.000 14.111 9 to 0.0099 120 0.0 0.0 4.520 3 80.39 0.0018 13.000 0.023 Vel = 1.768 3 80.47 4.31 13.000 14.134 0.0 to 120 0.0 0.0 13.000 5 160.86 0.0063 13.000 0.082 Vel = 3.537 5 65.86 4.31 13.000 14.216 to 120 0.0 0.0 7 226.72 0.0119 13.000------- --0.1-55 Vel = 4.986 7 -21.18 4.31 13.000 14.371 to 120 0.0 0.0 9 205.54 0.0099 13.000 0.129 ---.,Ve-l--= 4.520 9 -21.37 4.31 13.000 14.500 to 120 0.0 0.0 11 184.17 0.0082 13.000 0.106 Vel = 4.050 1 -21.96 4.31 13.000 14.606 to 120 0.0 0.0 13 162.21 0.0064 13.000 0.083 Vel = 3.567 13 -22.94 4.31 13.000 14.689 to 120 0.0 0.0 15 139.27 0.0048 13.000 0.063 Vel = 3.063 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard EAGLE FIRE PROTECTION INC. Page 9 COST PLUS SANFORD Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 15 -24.27 4.31 to 0.0 120 17 115.0 0.0034 17 -25.95 4.31 to 14.796 120 19 89.05 0.0022 19 -27.92 4.31 to Vel = 120 21 61.13 0.0011-1 21 -29.55 4.31 to 139.55 120 23 31.58 0.0003 23 -31.59 4.31 to 0.0 120 25 -0.01 0.0 25 0.0 4.31 to 14.837 120 27 -0.01 0.0 27 0.0 4.31 to Vel = 120 29 -0.01 0.0 13.000 14.752 4.31 to 0.0 0.0 31 -0.01 13.000 0.044 Vel = 2.529 13.000 14.796 0.212 Vel = 5.911 2 0.0 0.0 to 13.000 13.000 0.028 Vel = 1.958 9.375 14.824 4.31 to 0.0 0.0 6 139.55 9.375 0.010 Vel = 1.344 10.250 14.834 120 8 0.0 0.0 8 21.17 10.250 0.003 Vel = 0.694 12.542 14.837 0.0118 10 0.0 0.0 to 13.000 12.542 12 Vel = 0.0139 13.000 14.837 13.000 0.0 0.0 4.958 13.000 13.000 Vel = 0.0 13.000 14.837 13.000 0.0 0.0 5.428 13.000 Vel = 29 0.0 4.31 to 0.0 120 31 -0.01 0.0 0.0 0.0 268.81 0.0163 -0.01 0.212 Vel = 5.911 2 69.76 4.31 to 13.000 120 469.76 120 0.0014 4 69.79 4.31 to 0.018 120 6 139.55 0.0048 6 64.76 4.31 to 120 8 204.31 0.0098 8 21.17 4.31 to 120 10 225.48 0.0118 10 21.37 4.31 to 13.000 120 12 246.85 0.0139 13.000 14.837 4.31 13.000 0.0 9.961 120 13.000 0.0 Vel 268.81 0.0163 13.000 0.212 Vel = 5.911 14 22.94 24.798 KFactor =---- 13.000 15.600 120 0.0 0.0 16 291.75 13.000 0.018 Vel = 1.534 13.000 15.618 0.0 0.0 13.000 0.063---- Vel. -=-3.069 13.000 15.681 0.0 0.0 13.000 0.128 Vel = 4.493 13.000 15.809 0.0 0.0 13.000 0.153 Vel = 4.958 13.000 15.962 0.0 0.0 13.000 0.181 Vel = 5.428 12 21.96 4.31 13.000 16.144 to 120 0.0 0.0 14 268.81 0.0163 13.000 0.212 Vel = 5.911 14 22.94 4.31 13.000 16.356 to 120 0.0 0.0 16 291.75 0.0190 13.000 0.247 Vel = 6.416 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard EAGLE FIRE PROTECTION INC. COST PLUS SANFORD Page 10 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. VIC., or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 16 24.28 4.31 13.000 16.603 to 120 0.0 0.0 18 316.03 0.0221 13.000 0.287 18 25.94 4.31 13.000 16.890 to 120 0.0 0.0 20 341.97 0.0255 13.000 0.332_..__.___ Vel__ 7.520 20 27.92 4.31 9.375 17.221 to 120 0.0 0.0 22 369.89 0.0294 9.375 0.276 Vel = 8.134 22 29.55 4.31 10.300 17.498 to 120 0.0 0.0 24 3_99.44 0.0340 10.300 0.350 ___VeI =--8.784 24 31.58 4.31 1 E 13.937 26.000 17.848 to 120 13.937 0.0 TOR 431.02 0.0391 39.937 1.563 Vel =9.478 TOR 0.0 4.31 1 B 16.724 20.000 19.411 to 120 1S 30.661 47.385 9.095 BOR 4_31.02 0.0391 67.385 - ---- -- - Vel = 9.478 BOR - 100.00 6.08 1T 45.881 50.000 31.143 K Factor= 100.00 to 150 1 E 21.411 71.877 0.0 U1 531.02 0.0071 1G 4.588 121.877 Vel = 5.868 U1 -170.05 7.98 6F 13.591 ----0.869 2013.000 32.012 to 150 2G 6.041 161.579 0.0 U2 360.97 0.0009 1S 67.957 2174.579 2.020 Vel = 2.316 U2 0.0 9.79 2F 14.844 533.100 34.032 to 150 1G 6.747 66.121 0.0 U3 360.97 0.0003 1 E 29.689 599.221 0.206 Vel = 1.538 0.0 360.97 34.238 ------ K Factor -=_ 61.69 U1 170.05 7.98 1G 6.041 134.080 32.012 to 150 1T 52.855 58.893 0.0 U4 170.05 0.0002 192.973 0.045 Vel = 1.091 U4 ..... ... 150,00 7.98 2E 27.183 2792.890 32.057 Qa = 150 to 150 3G 6.041 140.438 0.0 U3 320.05 0.0007 5F 13.591 2.181 Vel_ 2.053 U3 360.97 9.79 2E 29.689 ,2.933.328 10.000 34.238 to 150 59.375 8.000 Fixed loss = 8 BK 681.02 0.0011 69.375 0.077 Vel = 2.903 BK 0.0 9.79 1T 67.474 103.000 42.315 to 150 1G 6.747 74.219 0.0 TEST 681.02 0.0011 177.219 ---.0.197 Vel 2.903 .0 681.02 42.512 K Factor = 104.45 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram EAGLE FIRE PROTECTION INC. Page 11 COST PLUS SANFORD Date 1 -> 80.39 100 -> 54.67 101 -> 29.87 102 - 5.16 103 r 19.54 104 r 44.38 105 r- 69.76 2 T 80.39 T 69.76 3 - 811.47 106 - 54.74 107 -i 29.91 108 -+ 5.19 109 F 19.53 110 F 44.39 111 F 69.79 4 T 160.86 5 -i 65.86 112 - 39.69 113 --> 13.67 114 i- 12.30 115 F 38.33 116 F 64.76 6 T 226.72 7 <- 21.18 8 T 205.54 T 225.48 9 <- 21.37 10 T 184.17 T 246.85 11 F 21.96 12 T 162.21 T 268.81 13 - 22.94 14 T 139,27 T 291.75 15 24.28 16 T 115.00 T 316.03 17 25.94 18 T 89.05 T 341.97 19 27.92 20 T 61.13 T 369.89 21 29.56 22 T 31.58 T 399.44 23 31.58 24 1 O.ol 25 x-11 26 1 - 811.39 3 160.86 5 226.72 7 F- 205.54 9 F 184.17 11 162.21 13 139.27 15 115.00 17 89.05 19 61.13 21 t 31.58 23 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram T 21.18 T 21.37 T 21.96 T 22.94 T 24.28 1 25.94 T 27.92 T 29.56 1 31.58 2 F 69.76 4 F- 139.55 6 204.31 8 225.48 10 F 246.85 12 F 268.81 14 291.75 16 <- 316.03 18 e- 341.97 20 <- 369.89 22 399.44 24 Ul - 170.05 U4 <-- 320.05 U3 - 681.02 BK < 681.02 TEST Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram EAGLE FIRE PROTECTION INC. Page 12 COST PLUS SANFORD Date 23 -, 0.01 25 -> 0.01 27 - 0.01 29 -> 0.01 31 T 31.58 24 - 431.02 TOR F 431.02 BOR F 531.02 U1 - 360.97 U2 r- 360.97U3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ` SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: October 22, 2004 ' Business Address: 2251 W.P. Ball Blvd Occ. Ch. #36 Mercantile Business Name: Cost Plus Sanford Store Ph. ( ) Contractor: Eagle Fire Protection Inc. Ph. (407) 656-8387 FAX (407)}656-9405 Reviewed [ ] Rev�tewed w1thComment [X ] Rejected [ ] ._. Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Instillation of One (1) types of design area. Exposed Ceiling. 177 total fire sprinkler head installation Application— Per N.F.P.A. #13-1999 Ed, • Tamper switches required on all inside and outside fire sprinkler valves • Two hour above hydro, and flush required • Do not block access, and fire inspector test valves • 2 hour hydro and flush required 1 CONTENTS 1) VIHING SPRINKLERS v ./ 2) ALLIED PIPE DYNA-FLOW/" 3) ALLIED PIPE SCH 10-40 4) ANVIL THREADED FITTINGS 5) GRUVLOK GROOVED PRODUCTS 6) HANGERS , RINGS,BEAM CLAMP 7) AGF TEST AND DRAIN VALVE 8) BALL VALVE ✓- 9) FLOW SWITCH , ELEC. BELL May 2, 2003 VIKIIVGP 1. PRODUCT NAME Viking Micromatic® Model M and Micro- maticHP® Model M Standard Response Sprinklers -Available Styles: Upright, Pendent, and Conventional 2. MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION Viking Micromatic® and MicromaticHP° Standard Response Sprinklers are small thermosensitive spray sprinklers available in several finishes, temperature ratings, and orifice sizes to meet design require- ments. The small frame and 5 mmglass bulb provide a pleasing appearance. Used in conjunction with one of the various cor- rosion -resistant coatings, the units provide protection against many corrosive environ- ments. In addition, the Polyester finishes and Teflon® coating can also be used in decorative applications where colors are desired. During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flow- ing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Viking Standard Response Glass -Bulb Style Sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap as- sembly removed) on deluge systems. 4. TECHNICAL DATA LISTINGS AND APPROVALS Refer to the charts on pages 11 b -d. Spacing Requirements: Max. spacing 15 ft. (4,6 m), min. spacing 6 ft. (1,8 m). Glass bulb fluid temperature rated to -65 °F (-55 °C). Spring: U.S.A. Patent No. 4,167,974 Min. Operating Pressure: 7 psi (48,3 kPa). RATED WATER WORKING PRESSURE Sprinklers 09992, 09993, 09994, and 09995 are rated for use with water working pressures ranging from the minimum 7 psi (48,3 kPa) up to 250 psi (1 724 kPa) for high-pressure sys- tems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (1 207 kPa) wwp. Factory tested hydrostatically to 500 psi (3 448 kPa). SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Brass UNS-C51000, Brass UNS-C26000, or Copper UNS-C19500 Sprinkler 11 a MICROMATIC® AND MicromaticHP® STANDARD RESPONSE SPRINKLERS for Sprinkler Base Part No. 09992. Brass UNS-C51000 or Copper UNS-C19500 for Sprinklers 10139, 10142, 10170, 10173, and 10223. Cop- per UNS-C19500 for Sprinkler Base Part Nos. 10138, 10141, 10169, 10174, 10187, 10190, 10193, 10220, 10233, 12105, and 12106. Brass UNS-C26000 for all other Part Nos. Bushing (for Sprinkler Base Part Nos. 09994, 09995, 10188, 10189, 10191, 10192, 10218, 10219, 10221, and 10222): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09992, 09993, 09994, 09995, and 10221: Bronze UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinkler Part Nos: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (Part Nos. 12105 and 12106): Stainless Steel Wire Sprinklers with Teflon® Coating Belleville Spring Sealing Assembly: Ex- posed Screw: Nickel plated Pip Cap: Teflon® Coated Sprinklers with Polyester Coating or Poly Finish Belleville Spring Sealing Assembly: Ex- posed AVAILABLE FINISHES Brass, Bright Brass, Chrome-Enloy° (pat- ents pending), White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon° in all temperature ratings; Wax -Coated Brass or Wax over Polyester* for sprinklers with temperature ratings through 286 °F (141 °C). Wax Over Polyester unavailable for Sprinkler Base Part Nos. 09992, 09993, 09994, and 09995. Note: Units of measure in parentheses may be approximations. Replaces page 11 a -d, dated March 28, 2003 (updated the approval Form No. F 100397 chart). Refer to technical data page SR1-2 for general care, installa- tion, and maintenance information. H Upright Pendent Conventional Sprinkler Temperature Nominal Sprinkler Temperature Max. Ambient Bulb Classification Rating Fusin Point)__ Ceiling Temperature'- Color2 dmm -1552E-(68-!Q- 00-!E-(3_ ° -Bed Intermedial 175 ° 79 °C 150 °F 6 °C Yellow Intermedial 20 9 °C 150-F 65-C) _ Green _ ° 100 =C)-.8fi°F-�0�(fi5 °�L-e1L --T --------NL9h -- __._2(141 -..'C)__._._ -225..°F._(107° C)..._...___..._._BI�e..._... Extra High 36 °F (1 82 ° 300 °F 149 °C Mauve -..._._._...Ultra High ---..._..._.. ----....... 500..°F._(260...°C)........... ..............465_'F..(240_`C). ......... .........._Black...... Sprinkler Finishes: Brass, Bright Brass, Chrome-EnloyO, White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon® Corrosion -Resistant Coating S3: White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon® in all tem- perature ratings. Wax -Coated Brass and Wax over Polyester finish5 for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax 175 °F (79 °C) Brown Wax 212 °F (100 °C) Brown Wax I Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2 The temperature rating is stamped on the deflector. 3The corrosion -resistant coatings have passed the standard corrosion test required by the ap- proving agencies indicated on pages 11 b -d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indi- cated are applied to the exposed exterior surfaces only and, therefore, the sprinklers can- not be used as o�en sprinklers. Note that the spring is exposed on sprinklers with Poly fin- ishes and Teflon coatings. Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or sim- ilar enclosures with normal operating temperatures above 300'F (1 49 °C). Where the ambi- ent temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 5 Wax Over Polyester unavailable for Sprinkler Base P/Ns 09992, 09993, 09994, and 09995. for Sprinkler Base Part No. 09992. Brass UNS-C51000 or Copper UNS-C19500 for Sprinklers 10139, 10142, 10170, 10173, and 10223. Cop- per UNS-C19500 for Sprinkler Base Part Nos. 10138, 10141, 10169, 10174, 10187, 10190, 10193, 10220, 10233, 12105, and 12106. Brass UNS-C26000 for all other Part Nos. Bushing (for Sprinkler Base Part Nos. 09994, 09995, 10188, 10189, 10191, 10192, 10218, 10219, 10221, and 10222): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09992, 09993, 09994, 09995, and 10221: Bronze UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinkler Part Nos: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (Part Nos. 12105 and 12106): Stainless Steel Wire Sprinklers with Teflon® Coating Belleville Spring Sealing Assembly: Ex- posed Screw: Nickel plated Pip Cap: Teflon® Coated Sprinklers with Polyester Coating or Poly Finish Belleville Spring Sealing Assembly: Ex- posed AVAILABLE FINISHES Brass, Bright Brass, Chrome-Enloy° (pat- ents pending), White Polyester (White Poly finish for Sprinkler Base Part Nos. 10138, 10139, 10141, and 10220 only), Black Polyester, and Black Teflon° in all temperature ratings; Wax -Coated Brass or Wax over Polyester* for sprinklers with temperature ratings through 286 °F (141 °C). Wax Over Polyester unavailable for Sprinkler Base Part Nos. 09992, 09993, 09994, and 09995. Note: Units of measure in parentheses may be approximations. Replaces page 11 a -d, dated March 28, 2003 (updated the approval Form No. F 100397 chart). Refer to technical data page SR1-2 for general care, installa- tion, and maintenance information. Sprinkler 11 b May 2, 2003 ® MICROMATIC® AND ®� MicromaticHP® STANDARD RESPONSE SPRINKLERS Approval Chart Temperature KEY Micromatic® Standard Response Pendent Sprinklers Finish 75 PSI WWP Al Thread Max. Nominal Overall essure Sprinkler Description Listings and Approvals2 K— act en th ' Base Part - — _ NPT. BSP PSIG Style 1 SIN U.S. ' metric6 Inch mm cULus° FM NYC3 VdS LPCB _----- .._._ Number- _ -- - _. Pendent.. _101.3.9 .._ VK142 . 5 6 .- ..8,1 __._ 2-311.6 _56 B2, D11, E13, F9 - 67,.G6,F7 ._62,_D] 1, .E1.3 68 _'_68, D.4. 175 _......P.endent__-_10]..73.2._. _.V.K102 56...__ .8,t.....__ 23!]6._56.._6..1.,.D]O,..E13........_B9,_.C.1.2,A8._B_1„_D..].Q._E13 B.8,..D3. .f. 9_C72,_F9_ R?- - - - VK2 B13L1� 175,_QLO,-Et Li6 8,�2, Fg R1 _ - �Q3 --_L15_= 175 Pendent 10187 _VK2Q28"0 B1,D10_E1 - - - 175 Pendent _j12 8_0 T___].. 12_ A - - Q3 .3/4 20 mm 175 Pendent 12105 R7 1 --- -- --- -- -- -- _ -- -_-- Small_ r"ice9 ..._ _. ._.. __. --__.. r ...... ....... Yz __15mm .._.._175 _._Pendent. .]022tt0__ VK0.0.3. 28 4,0.-___. -31-16 5S- Bi.,_DiD,Et3_.... B9,_D.12 - _'lz".._i..]_5..mm. __--_.1..75...._.... -Pendent- _-1..02221 °....-_VK0.04._ --.4.2_.._.1...__.6..0.__._ _2114-.. 58____B_1.._D10,_E1.3___..._......____.-_..__---..----._....----.____-- Pendent. _- 10175 _._ VK003_ 4.2 6,Q_ .._2_1/4 .._58 10,12 15 mm ......175 P_endeo ]0]88 VKQQ4.. ..4.2 60 _ 2-114 _5.8 _.B.1,D.14 E13-__ 01z __ ].5 1.7.5--,.._P.ende.nt .10-1.8.9.1.-__._ VK4.0.3_ 4 ®___.2_3116 _56 BtD10,.E13..__ 89,.D_12 Ins led with the Vikin E-2 CSJ.t.Ch80n11 DS D2 8 ni - - 175 -Pendent 9,10VK003DI 175 Pendent 9,10 VK004 D1 D8 1 Di -3/4" ! s i Di Di _15mm ___175 _. P_endent___1017312_.._VK1.02.- 5_6__-;_ 8.,_l._..__. _3L]Si_56 ._ D1 ._...__. _CBe. A1....... ._._ .20-m __175 ...Pendent_ _.1017012:... V_K242_ ] 1.,5 . _.2 318 ..fi0 ._ . DL _.. D88__. - - --D] .._ 3J4 24 mm ._.175 Pendent ___12105__._ - VJS202.. 8 0 '._ ] 1..5 .2 31-16 _5Ci __.-_ _ _ D7 = --_ _...._.._- ..... _ __ _.. __ . nstafled 'th .the.Y lung Microfasi _Made F-1 djustable. Escu cheon1 1. , /i t..5 mm ..._.175 . _P_endent. __ 10.1.39_.._. VK102.. 5.6 _.. 8.1_.2-7311f ._56 02 E8..:_ ..D2 ..... _.._.175_ .....P.endent_ _._._10223 _...._VK202_ _8_0_-_-i_ 11.,6._._ 2:3/8..__60._ _ ......_D1....... .... .__ D] _. ...... _.. 15..mm---.1..Z5___... _P_eodant. _022.]_9'10__V-KQ03 ..._.2.8._ _-.._4,.0......_ 2.3Li6. ,.E8.__....._.D_1..__.. 7 9,10 ...... _...__.__.__.Di ..... --_.... ._._ 4°i2Qm 115 mm. X11. - _ $_' D1 12 1— _ 175 Pendent 96 Di 120 -3/16 - - 1 z 1.5 !4” 20 m� - - - 7 Approved Finishes 1 - Brass, Bright Brass, Chrome-Enloy®, White Polyesters, Black Polyesters, and Black Teflon®s Approved Temperature Ratings 2 - Brass Bright Brass, Chrome-Enloy®, White Poly Finish5, Black Polyesters, and Black Teflon6s A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) ! 3 - Wehite Polyester, Black Polyester, Black Teflon®, Wax -Coated Brass, and Wax over Polyes- °C), 286 °F (141 °C), and 360 °F (182 C>100 4 - White Poly Finish, Black Polyester, Black Teflon®, Wax -Coated Brass, and Wax over Poly B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Finish 286 °F (141 °C), and 360 °F (182 °C) 5 - Brass, Bright Brass, Chrome-Enloy®, and White Poly Finish C 155 °F 68 °C , 175 °F 79 °C 200 °F 93 °C 6 - White Poly Finish and Wax -Coated Brass (corrosion resistant) ( ) ( ) , , 7 - Brass, Chrome-Enloy® and White Poly Finish and 212 °F (100 °C) D - 155 °F 68 -C), 175 °F 79 °C 200 °F 8 - Brass, Bright Brass, and Chrome-Enloy® ) ( ) ,and (93 °C)( 9 - Brass and Chrome-Enloya E - 286 °F (141 °C1 10 - Wax -Coated Brass and Wax Over Polyester (corrosion resistant) F - 500 °F (260 °C)7 11 - Wax -Coated Brass and Wax Over Poly Finish (corrosion resistant) 12 - Wax -Coated Brass (corrosion resistant) 113 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temTerature allow d at Piling 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. XII. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion -resistant. 6 Metric K -factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiplythe metric K-factorshown by 10.0. 7 Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300 °F (149 °C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra -High temperature rated sprinkler may be severely retarded. 6 FM Approval of Viking Micromatic® Standard Response Recessed Pendent Sprinklers installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon is limited to wet systems and preaction systems qualifying as wet systems, for hazard occupancies up to and including Ordinary Hazard, Group II. 9 Listings and Approvals limited to Light -Hazard Occupancies with hydraulically calculated wet sy ;ems only. 1oThe sprinkler orifice is bushed. ,,Refer to the "Sprinkler Accessories" section for technical data on approved escutche n nd r fccessories. scutcheons must be or- dered separately from sprinklers. Refer to Viking's current price schedule. , r �r of�-e00 12 Sprinklers 10173, 10170, "'TTTddd 10189, and10188 are available on special order. y Spacing Requirements: Maximum spacing 15 ft. (4,6 m), minimum spacing 6 ft. (1,8 m). � Sprinkler 11 d May 2, 2003 11111111 AIF M P�� S MICROMATIC® AND ®� A MicromaticHP® STANDARD WN RESPONSE SPRINKLERS Approval Chart Temperature KEY Finish Micromatic® and MicromaticHP® Standard Response Al _.__._..._._.......... ... __ Upright and Conventional Sprinklers_ Maximum 175 PSI WWP Standard Orifice Thread Size ...... _ Max. pressure_ Sprinkler Description Nominal _ K-Factor Overall Len th Listings and A 2 9 pprovalsBase BSP PSIG PartNPT Style NumbersSIN S. Imetncs ;U5 Inch mm cULus4 FM NYC VdS LPCB175 U n ht p 9 10138 VK100 6 8 1 2-3/16 5662 E12F14G10A8 D7Ge 3 62, E12, Ft4%2 15 m�Qppr,,'g ht 10233 VK1005.6 8,1 2-3/16 56 - A8 D7 G8 B8 B9 E3 - 15 mht — 10.174 VK100 5 6 8 1 2-3/16 56 - A8, D7,_G8 - B9, E3 15 mht 10193 VK100 5.6 8,1 2-3/16 56 B1 E11 F14 G10 A8 D7 G8 B1 E11 F143 _ Lar a Orifice 'A" 15mm 175 U ri ht 10220 VK200 8.0 115 2-38 60 132 E12 Fla G10 B8 E13 G8 B2 E123 - 3/4" 20 mm 175 Uri ht 10141 'VK200 8.0 11 5 2-5 16 59 B2 E12 F14 G10 B8 E13 G8 B2 E12 F143 B9 B9 E4 15 mm 175 Upright 10190 1VK200 8.0 11 5 2-3 8 60 B1 E11 F14 G10 B8 E13 G8 20 mm 175 Upright 10169 VK200 _ 8.0 11 5 2-5/16 59 Bt E11 F1 J_y- 4 _ B8E13,. GS__.._ --- -- - - - Small Orifices _1/2" 15 mm 175 Uri ht 102189 NK001 2.8 4,0 2-3/16 56 B1 E11 F14 E10 E13 1/2 15 mm 175 Upright 102199 !VK002 4.2 ! 60 2-316 56 81 Eft F14 ----- 15 mm 175 AIL l_101919_ VK002 __ 4.2_--.._ 6 0..__. 2-3J16 56. 61 E11 F14- 15 mm 175 Upright 101929VK001 2.8 4.0 2-3/16 56 B1 E11 F14 E10 E13 10 mm 175 Uri ht 10176 !VK001 4.2 ' 6.0 2-3116 56 - - BS 1139, E3 -- _ Conventional Y2" 15 mm 175 Conv. 10227 VK118 5.6 8,1 2-3/16 56 B1, E11, F14 _ - B1, E11, F14" B8 E11 3/4" 20 mm 1.75 Conv_ 10228 VK120 8.0 7111,5 2-5/16 59 B1, E11, F14- 81, E11, F1411 - 5, Ell 15 mm 175 Conv. 1017270 VK118 5.6 , 8,1 2-3/16 56 B1, Eli, F14 B5, E11 20 mm 175 Conv. 1016870 'VK120 8.0 j 11,5 2-5/16 59 61, E11, F14 - _ _ _ B5, 314 20 mm 175 Conv. 12106 VK120 8.0 11 5 12-5/161 59 - gg Maximum 250 PSI WWP _— Standard Orifice _ 15 mm 250 Lght r 09993 1VK124 5.61 8=1 2-1 4 58 C1 _.__ __ Small Orifices _[U 15 mm 250 Uri ht 099959 VK021 2.8 4 0 2-1 4 58 C1 Approved Temperature Ratings Approved Finishes 1 -Brass, Bright Brass, Chrome-Enloy®, White OF Polyesters, Black Polyesters, and Black Teflon®s °C), OF °C), OF A -155 (68 175 (79 200 2 - Brass, Bright Brass, Chrome-Enloy®, White P?V Finishs, Black Polyesters, and Black Teflon®s (93 °C), 212 OF (100 °C), 286 OF (141 °C), 3 -White Polyester, Black Polyester, Black Teflon Wax -Coated Brass, and Wax over Polyester and 360 OF (182 °C) 4 -White Poly Finish, Black Polyester, Black Teflonb, Wax -Coated Brass, and Wax over Polyester B - 155 OF (68 °C), 175 OF (79 °C), 200 °F ! 5 - Brass, Bright Brass, Chrome-Enloy® White Polyester, and Black Polyester (93 °C), 286 OF (141 °C), and 360 OF ` 6 - White Polyester, Black Polyester, and Wax -Coated Brass (182 °C) 7 - White Poly Finish and Wax -Coated Brass (corrosion resistant) C - 155 OF (68 °C), 175 OF (79 °C), 200 OF 8 - Brass, Chrome-Enloyo and White Poly Finish (93 °C), and 286 OF (141 °C) 9 - Brass, Bright Brass, and Chrome-Enloy® D - 155 OF (68 °C), 175 OF (79 °C), 200 OF 10 - Brass and Chrome-Enloye (93 °C), and 212 OF (l 00 °C) 11 - Wax -Coated Brass and Wax over Polyester (corrosion resistant) E -155 OF (68 °C), 175 OF (79 °C), and 200 OF 12 - Wax -Coated Brass and Wax over Poly Finish (corrosion resistant) (93 °C) 13 - Wax -Coated Brass (corrosion resistant) F - 286 °F (141 °C) 14 - 200 OF (93 °C) High -Temperature Wax Coating (corrosion resistant); maximum ambient tem - G - 500 °F (260 °c)� perature allowed at ceiling = 150 °F (65 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. XII. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion -resistant. 6 Metric K -factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K -factor shown by 10.0. 7 Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating tempera- tures above 300 OF (149 °C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 OF (149 °C), the response time of the Ultra -High temperature rated sprinkler may be severely retarded. 8 Listings and Approvals limited to Light -Hazard Occupancies with hydraulically calculated wet systems only. 9 The sprinkler orifice is bushed. 10168 and10172 are available on special order. IOSprinkiers Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. III. Spacinq Requirements: Maximumspacing 15 ft. 4,6 m), minimumspacing 6 ft. 1,8 m). mepiaces page 11 a -d, dated March 28, 2003 (updated the approval chart). Refer to tech- Form No. F100397 nical data page SRI -2 for general care, installation, and maintenance information. - s, v. u� `'&`CONDUIT Schf'/--".duleml0o/*A�chedule=400 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1'/4"- 8") pipe and Sch-40 (V- 2%2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF'. In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test "tl, cal Flow Control P allied TUBE & CONDUIT UL FM ULC S044 .- 16100 S. Lathrop • Harvey, IL 60426 Customer Service: - (800) 882-5543 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wi/Lilt (24') WVLift (25' In; mm In; mm Lbs/Ft, Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1'/a" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1'/z' 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2'/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 "tl, cal Flow Control P allied TUBE & CONDUIT UL FM ULC S044 .- 16100 S. Lathrop • Harvey, IL 60426 Customer Service: - (800) 882-5543 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WVLift (21') Milt (24') WVLift (25' In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1'/z' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 11439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2'/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 "tl, cal Flow Control P allied TUBE & CONDUIT UL FM ULC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 t rh`" A BF LB VfIMAI mF >L F DynauFlow@ 1Strength Steel 1 p • The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule -10. Dyna -Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna - Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule -10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna -Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule -40 and up to 7% larger than Schedule -10, Dyna -Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna -Flow, and related components, to be down -sized within the system, thus increasing the potential for job cost savings. For complete Hazen - Williams charts, refer to "Dyna -Flow Hydraulic Data Tables." Coatings & Fabrication Specifications &Approvals Dyna -Flow products are coated with an environmentally approved and specially formulated modified -acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. tgca/Flow Control Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. U� FM USC Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft 0. C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. �III�� 16100 S. Lathrop • Harvey, IL 60426 Customer Service: LTJ 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Liff (21') Wt/Lift (24') Wt/Lift (25' In; mm In; mm Lbs/Ft; K91m Lbs/Ft; Kg1m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1'/," 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 1'/z" 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2" 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2'/2' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3" 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4' 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Coatings & Fabrication Specifications &Approvals Dyna -Flow products are coated with an environmentally approved and specially formulated modified -acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. tgca/Flow Control Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. U� FM USC Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft 0. C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. �III�� 16100 S. Lathrop • Harvey, IL 60426 Customer Service: LTJ 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 Malleable Iron Class 150 (standard) `\\. '�� INTEgNATIONpE. INC. ALL ELBOWS & TEES 5/6" AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01) Size A i Weight (lbs) =Figure1101 (NPS) (in) ; black galy. '/e i/IB 06 .07 .12 .........__...__........_r_.__......_._._.._..._' 1/e ................... 'S/Is 1 ................. .17 ... ...:._............. ... ... ... ... ....._..._.... .17 -I 1'/e .26 .27 1/4 .... 15/16 .38 1 .43 1 1'/z .63 .65 1'/4 1'h .96 .94 ._................—__......._............_........... 1's/le 1.30 1 34 f g ti .... 2 2'/4 2.06 2.01 i 2'/2 2"/Is 3.54 3.64 j I------;— �- } 3 3146 5.20 5.35 A 3Yz... i....._3'/Iq......._ 7.19 4 ................7.10 3"/16 8.95 9.37 ... _... _....... ..__;._..._. 5 41/2 13.90 1 14.50 6 j 5'/e 23.00 1 23.50 ALL ELBOWS & TEES 5/6" AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01) Malleable Iron Class 150 (standard) Straight Tee S�,eA Pressure,(psig) Weight (Ibs) Figure 1105 (Nin) 20°to 150° 300 black galy. 'A "/,6. .09 .10 350° 150 j 3151-111. 415 400° ._... ; ... 1..id, 15 ........... _. 16 _..225 325 ......... .. _ . { —i 15/16 550° 130 230 Note: Unions with Copper or Copper Alloy seats are not intended for use where _1'/e .23 .24 %z .36 .37 'A15/16 .56 .58 1' 1'/z .90 .92 s .. 13/4 1.31 1.35 115/16 1 1.73 1.79 2 2'/4 2.52 2.80 Ate, r.........._._ ................ 21/z 1 21 /,6 i......-..._._........._..._.. € 4.90 5.02 A 3 3'/, 6 7.12 7.25 - ---;-- --� ......._. 3'/2 .. 3'/16 ... 9.00 9.40" A 41 -- 3"/1s 11.31 12.30 5 ......._._.........._...__ 4'/2 19.42 .. 19.51 :........................... 6 1 _._;.............._ 5'/8 .............. ....;_.._......... 2 5.5 0 29.9 * POA. Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Pressure,(psig) Temp (°F) Class Class Class 150 250 300 20°to 150° 300 _500_.___60_o 250-...... 225 405 ......, 505 300° 185 360 460 350° 150 j 3151-111. 415 400° ._... ; ... 1..id, 270. 370 .._.._. 450 -75 _..225 325 ......... .. _ . { —i ......180 280 550° 130 230 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F Anvil Class 150 (Standard Weight) Malleable Iron Fittings conform to ASME B16.3 and Unions conform toASME B16.39. Anvil standard weight banded pattern fittings in this catalog, sizes '/x NPS to 6 NPS inclusive, are included in the "List of Inspected I lil I,IjI TM 4 INTER NATIONAL, INC. Fire Protection Equipment and Materials"issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES V AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/90/01) Malleable Iron Class 150 (standard) Reducing Tee Figure 1105R Z Y ' / I r ----i, -�- x Size (NPS) x y Z !(in) (in) (in) I j Iblack Wt. (lbs) gale. V. 314 .12 .14 7 1/8. 1 3/,- i 3/41 /4 "/is; "/is: 1/8 .13 .19 1 .14 .20 1/4 3/, 7/1 1 "/16 "/16 11/6 i -.19-T-.20 .29 .29 V4 % '12 7/6 1/8 1'/16 1 1'/16 I 1'/16 f 21 j .26 .22 .29 V, V, I V, i 1'/s .30 .31 % % V/16 V/16 28 29 '/4 V2 '/B '12 1/4 1 1 1 1 V/16 V/16 V /16 A '14 1 '14 13/16 13/8 1 % 1'/4 .27 .30 i .43 .55 .29 . 32 .45 .57 Vil 3/4 1A ' 15/16 - -45--T- 4-6 1 1/8 % 11/9 "/1 f; 1'/e .36` 1/4 2 2/4 115/,s l 2'/4 2.00 1.97 1,/16 11/8 1 5/16 46 48 1/2 1114 I .43 1 .47 314 3/4 2� 15/16 j 1'/4 15/16 /16 V/16 1'/8 .51 .38 .51 .40 1/8 1/8 11/0 1 1'/e .42 i .46` 3/4 i '12 1'/16 13/16 1 1'/4 .46 .49 17/16 i 1 762- .6-6 17/16 .90 j .93 1/4 15/16 1'/z .69 I .71 V2 1'/4 1 1'/e I % .55 I .55 '/2 '/4 1 '/4 13/, 11/16 .56 .62 11/2 1 11/2 .76 j .73 V2 1'/4 1'/161 1 % 59 .62 1 3/, 1 3/,j 15/16 17/16 .73 .75 1'/s /16 2 .78 .81 1/4 4 11/0 11/8 i 11/4 .55 .55 % 13/ 1'/le'1 V4 .66 T 7- 63 v, 1'/4 1T/4 i 13/. .70 .7 '/4 1 .82 1 .84 1 '/4 1 1 "A 6 V/16 1 .92 .97 1'/2 1 "/1611 "/16! 1'/e 1 1.19 1 1.24 2 2 2 1'/4 1 1.63 1.63 Size X y Z Wt. (lbs) / S ] NT n) I (7S) (in) (in) (in) -black galv. 16 13 3/8 111/16 F .87 1 .94 11/, 1 /1 13/4 1.0 4 1-07 1/4 i 3/4 1 7/16 1 '/16 1 1 1/8 .86 1.86 3/4 1 --/,s .96 .88 i 1'/4 1 13/4 1 11/8 1 1.09 1.10 i '12 13/8 1 1'/4 1'/I6 .76 .79 1 3/4 17/16 1 3/a 1, 15/s .87 1.92 '/1 1'/z 11"/1s 11 1 1.13 !1 Aj 13/4 1 11/161 11/41 1 .13 1.1 1 3/s 1 1'/4 11/4 1'/16 .86 .89 3/. 13/8 E 19h 6 ..98 1 .98 1'/a 3/1117/16 17/1615/6 1.06 1-10 1/16 11/16 1 ' VI 6 1.18 1.22 1'/z' 7/, 1's 113/161 1.45 1.40 2 211s V/s 1'/8 1.70 1.82 16 1 "/16 1.35 1.42 1'/z 1115/16' �-13/4 3 �� :115/16:1 41 1.56 3/4 1'/z i 15/16 13/4 1 1.00 1.03 1 V211' /16 1'3/1611' /16 1.50 1.54 11'/411"/16 1 "A 6 V/s 1.30 1.44 4 1 1 '/2 1 '3/16 1.15 1 1.18 1'/2 '/2 1'/16 1 3/s 11 I/,B' 1.03 ;i 1.10 3/411'/2 1 '/16 1 13/4 1 1.08 1.10 1'/4 1 15/B 13/16 1.26 1.27 1'/4 t 1 "/16 13/4 1'/8 1.52 1.4 2 11'/2! 115/16 -1F/8 i I '/16 i 1.50: 1.55 1/2 1'/16 1'/16 1 '/16 1 .19 1 .25 '/4 1j 1'/z 11/2 13/4 1.29 1.40 1'/z 1 15/8 15/8 1 T16 1.44 1.49 !1'/4111J/,s s 1'/e 1.45 1.47 1 2 23/16 23/16 2 i 1.86 2.01 1/2 2 2/4 11/8 21/4 j 2.14 i 2.25 1/4 2 2/4 115/,s l 2'/4 2.00 1.97 1 2 2/4 4 2.28 1 1'/4 1 2'/s 1.72 1.79 1/3 3/4 .79.79 1 '/4 1 V2 2 1'/s 21A6 1.85 2.00 2 2/4 2'le2/4 2.20 2.25 1 13/, 1 5/a 2 1.58'1.61 2 1'/4 1'/e 1 "/is 2'/8 1.76 1.83 11/2 -2 ril/zi 11'5/16 21/16 1.95 1.95 2 2/4 23/16 2'14 1 2.24 i2.39 '/2 1'/z 1'/2 11/0 1.65 1.70 3/4 15/8 15/8 2 1 1.87 i 1.90 2 1 11/4 13/4 2 1.79 2.00 1'/s 12'/s 1 2.35 2.55 11/2 2 2 23A6 2.55 2.65 2'/2' 25/s 1 25A 23A T5703.5 9 IN TE R NATI ON AL, INC. Size X y Z Wt. (lbs) (NPS) i (in) (in) (in) black gaiv. 11/2 2 1 23X6 123/16 25A 13.43 i 3.51 3.80 i 3.80 1 2 i 23/9 2'/4 2/ 13.28 -1 L 1 3.32 2 1 1 2'x 6; 25/s 21V16 3.65 1 4.10 21/2 - 1- 4 13/4 1 1 3/4 V/6 AT�l -280 1 1'/s 2% 2.85 3.00 -- -- ---3-3 4 3- 47 T'14 2 Th .11/2 2'/16 23A6 2'/2 3.46 1 3.57 -T 2% 23/e 21/s 3.65 1 3.75 3 i 3 3 '2 "/la 5-82 16.00 2 i 2'/2 1 21/4 21A 4.10 1 4.30 2 i 3 31/s 9" 1 6.07 6.53 i 2 2'/2 i 23/s 1 2'/e 4.80 1 4.85 21/2 :2'/2;2'3/1612"/161 3 1 5.80 j 5.91 3 3/4 1'/6 `/B 25/o 1 4.02 i 4.22 1 2 1 2 i 25/e 4.15 4.36 '1'/4 23/16 i 23/16 ^2314.68 4.67 3 1 V2 1 21/,613 16 1 21/16 2 5.11 5.26 2 2'/z 5.79 1 5.81 6.09 6.22 3 1 4 313/16'35/s �!3'3/its 11 80111.00 4 t 2 1 23/4 21/4 3'/16 8.39 8.80 Y : ;1 4 21'//22 : 3'/, 6,* 3'/16 3/2 9.80 1 9.25 3 1 31/16 31/16 31A :11.02 11.30 www.anvilinti.com (12110101) Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Pressure, (psig) Temp (°F) Class Class Class 150 250 300 20° to 150° 300..._.'..........50.0.. _._.. 600 200.0._.... .__......:..........2.s5 - ! 455 550......._.. 25 0 0 -..._......._i......_._.2 ........... 2.5.. - - ...__._..4.0 5__..._.... _........_._....... _ 505 _3.Opa ---- 185... ,- 360..._.. 460....._.._ ..._._ .......... _.... _._-... ............. ._........__........................................e..............__.. 350° 150 1 315 415 __.._.__..._....______.......... ..___.... _.__ 110 1 270 ..----..-------._...__ .._.;._...__._...._._.__.. 400° 370 _._.._.....---......_..............:._.._._..__._.__..._.._....----.....__.. 75 I 225 325 --_..5.500_......_........._........................_......... L_......._1..30._......_.:...._......2.3.0.....___. Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F 1 1 �TM�I)I 1 f,,� IN TEPNATIONAL. INC. Anvil Class 150 (Standard Weight) Malleable Iron Fire Protection Equipment and Materials" issued by the Underwrit- Fittings conform to ASME 1316.3 and Unions conform to ASME ers' Laboratories, Inc. B16.39. ALL ELBOWS & TEES'h" AND LARGER ARE 100% GAS TESTED AT A MINIMUM Anvil standard weight banded pattern fittings in this catalog, sizes OF 100 PSI. 'A NPS to 6 NPS inclusive, are included in the "List of Inspected www.anvilinti.com (12/10/01) ^iall� Fire Protection Products Submittal Sheet GRUVLOK® UL/FM BUTTERFLY VALVE Figure AE7722-3A The Gruvlok Figure AE7722-3A Grooved End Butterfly Valve is UL Listed and FMRC Approved as a system control valve. The valve is r at 300 psi for steel pipe in the 2" to 10" sizes, and at 300 psi in the 1C size. The 2" through 10" sizes are agency rated for both indoor and outdoor service. The valve is supplied with two internal switches. One is wired for supe sory service and the other is wired for use as an auxiliary switch. Botf switches are rated for 0.5 amp at 125 VDC, 0.25 amp at 250 VDC, an amps at 125 VAC. The switches and actuator internal spaces are pro- tected from tampering and require special tools for disassembly. These tools are available from Gruvlolc® Manufacturing. The ductile irc valve body is encapsulated with a thick, durable polymer coating to ensure long term service. The valve disc is encapsulated with a thick coating of EPDM, and stems are 416 stainless steel. Detailed instructions for valve installation and switch wiring are include with each valve. Additional information for the replacement of shear pc components and switches is also provided. Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: I"TEMNAIION�t, INC. Approval Stamp: Page 1 of 2 Fire Protection Products Submittal Sheet I. UPPER STEM: Stainless steel, ASTM A-582, Type 416 2. STEM SHEAR PIN for valves 2" thru 6". Stem shear key for 8" & 10" valves. 3. UPPER BUSHING: PTFE bronze sintered on steel (8" x 10" valves only) 4. "O" RING: Nitrile 5. LOWER BUSHING: PTFE bronze sintered on steel (8" x 10" valves only) 6. LOWER STEM: Stainless steel, ASTM A-582, type 416 7. BODY: Ductile iron ASTM A-536 with polymer coating. 8. DISC: Ductile iron ASTM A-536 with EPDM encapsulation. 9. HAND WHEEL: Ductile iron 10. INDICATOR FLAG: Ductile iron 11. GEAR OPERATOR: Ductile iron and steel 12. NAMEPLATE: Aluminum 13. HANDWHEEL SHEAR PIN: Carbon steel AISI 1070 Page 2 of 2 T"z Fire Protection Products Submittal Sheet Figure 7400* Rigidlite® Coupling The Figure 7400 Rigidlite Coupling from Gruvlok is specially designed to provide a rigid, locked -in pipe connection to meet the specific demands of rigid design steel pipe. Fast and easy swing -over installation of the rugged lightweight housing produces a secure, rigid pipe joint. The Figure 7400 Rigidlite Coupling is UL Listed and FM Approved for 300 psi (20.7 bar) fire protection service in both wet and dry systems with roll grooved or cut grooved steel pipe prepared in accordance with Gruvlok grooving specifications. The Figure 7400 Rigidlite Coupling with a DRI-SEALT" style gasket is intended for use in fire protection systems installed in accordance with NFPA Standard 13 "Sprinkler Systems". �� INTfRNNtION nL. (, ❑ — Available galvanized When ordering, refer to product as FP7400. Project: Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: Approval Stamp: fII r OUPLING Range of Max. Wk. Max. End Pipe End Coupling Dimensions Coupling Bolts Approx. In./DN mm In./mm PSI/bar Lbs./kN In./mm In./mm In./mm In./mm QI . In./mm Lbs./K 110 1.660 300 649 0 - 10 250 430 130 2 30x 2V 1.3 :.7 t . 110 1.900 300 851 0 - 10 270 470 130 2 �ix 2V 1.4 2 2.375 300 1,329 0 - 10 310 510 130 2 3Ax 210 1.6 J,, 210 2.875 300 1,948 0 - 10 370 6 130 2 30x 2V 1.9 3 3.500 300 2,886 0 - 10 410 630 130 2 3A 230 2.1 4 4.500 300 4,771 0-1/1 550 730 170 5 2 3Ax 230 A Y 3.1 5 5.563 300_ 7,292 0 - 10 670 9Y 2 2 10x 3 4.6 76 6 6.625 300 10,341 0- 10 770 1 %1 2 2 10 x 3 5.5 46 8 8.625 300 17,528 0 -10 1010 12Y- 230 2 10 x 3 8.4 ,._ ,, , Project: Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: Approval Stamp: Fire Protection Products ' Submittal Sheet Figure 7050S* Standard 90° Elbow for Fire Protection * When ordering, refer to product as figure FP7050S. Project: Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: � HLEMNA ml — Available Schedule 10 — Available galvanized Above fittings are all cast malleable or ductile iron Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: �x V km VA Fire Protection Products Submitta MR l Sheet Figure 7051* Standard 45° Elbow for Fire Protection . When ordering, refer to product as figure FP7051. Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: INTERNATINNAI. INC. 0 ®i - Available Schedule 10 -'�- Available galvanized Above fittings are all cast malleable or ductile iron Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: Fire Protection Products ®R lu Submittal Sheet Figure 7060S* Standard Tee for Fire Protection * When ordering, refer to product as figure FP7060S, Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: Available Schedule 10 Available galvanized Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: ISI Max. Rated Center Approx. Nom. Size Pipe OD Pressure to End Wt. Ea. M , M 11/ ,4' 1.660 300 23/4 1.5 12.2 0 I Ih 1.900 300 23/4 1.8 2 2.375 300 31/4 2.4 21h 2.875 300 33/4 4.0 3 3.500 300 2"z . 41/4 5.8 4 4.500 300 5 10.3 5 5.563 300 51h 16.2 6 6.625 300 61h 25.7 !6'.' 8 8.625 300 73/4 41.1 Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: Available Schedule 10 Available galvanized Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: MAFire Protection Products Submittal Sheet Figure 7062 Bullhead Tee Project: Architect / Engineer: Date: Contractor: Address: Notes 1: �; Notes 2: Phone: l/ I L � (" NIf II IIAiIONAI, N(. ®i — Available Schedule 10 Fl— Available galvanized Above fittings are all fabricated steel. Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: Fire Protection Products Submittal Sheet Figure 7072 Concentric Reducer p F] ®j —Available Schedule 10 CAST WELD Project: Architect / Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: rr IN1f PNnTIONn L, INC. F 4ZF�— Available galvanized ■ - Cast malleable or ductile iron, all others are fabricated steel. Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: Fire Protection Products ylll Submittal Sheet Figure 7074* Cap * When ordering, refer to product as figure FP7074. Architect / Engineer: Date: Contractor: Address: Notes 1: Notes 2: Phone: ii INtERN �TION.R I. iN C. K ®i — Available Schedule 10 ]— Available galvanized Center to end dimensions and weights may differ from that shown in the chart. Contact your Gruvlok representative for details. Approval Stamp: Fire Protection Products ISubmittal Sheet Series 78FP UL/FM Fire Check Valve The Gruvlok 78FP UL/ULC Listed and FM Approved Check Valve is a compact, cost26in conjunction with grooved pipe and pipe couplings that are listed or approved for fire protection systems. Pressure Rating: 2" through 8" 78FP UUFM Check Valves have a maximum working pressure of 300 PSI (20.7 bar). Design Feature: In a full open position the 78FP UL/FM rubber faced swing clapper is held tightly against the valve body, out of the flow stream, to provide maximum flow area and prevention of clapper flutter. The clapper design produces quick, non -slam closure before flow reversal can occur, which provides a leak free sealing of back pressures as low as 1 PSI (0.07 bar) equivalent to 28" water head, meeting FM require- ments for an anti -water -hammer check valves. Applications: Appropriate for use in fire protection connections such as: • Fire Department pumper to sprinkler systems • Public water supplies to automatic sprinkler systems • Fire pump discharges and by-pass • Gravity and pressure tanks Hinge Pin Plug o" , J�F B 1 112" NPT �D E 1/2" NPT Project: Architect / Engineer: Date: Contractor: Address: Notes 1: F Notes 2: Phone: ru NIf RN.1TIONRt, iNf. Approval Stamp: Page 1 of 2 l Nominal Pipe Nominal Dimensions Valve Size 00 A B c D E F G Weight 2 2.375 63/4 23/6 17/16 13/4 414 33/16 43A 7.5 50 50.3 171 60 36 44 114 81 111 3.4 21h 2.875 71/4 27/16 19/16 13/4 31M6 3% 41h 10.5 65 73.0 184 61 39 44 96 92 114 4.8 3 3.500 73/4 25/b 2 113/16 411/16 311/16 415/16 11.5 80 88.9 197 67 51 46 103 93 125 5.2 4 4.500 811A 316 21/4 21h 51/16 41/4 6 13.5 100 114.3 206 79 57 64 128 108 152 6.1 5 5.563 93/4 31h 23/4 27/16 513/16 45A 63/4 19.0 125 141.3 248 89 70 61 147 117 171 8.6 6 6.625 123/4 41/4 35/16 31A 61/4 63/4 81h 33.5 150 168.3 324 108 84 79 159 171 216 15.2 8 8.625 143/6 51/16 315/16 4 515/16 8 101/4 59.0 200 219.1 365 128 100 102 150 203 260 26.8 Approval Stamp: Page 1 of 2 � Fire Protection Products Submittal Sheet Flow Data: The approximate friction losses, based on the Hazen and Williams formula, expressed in equivalent length of pipe is given at left. The friction losses have been calculated on the basis of flow rates typically used with each size valve. Important Note: Check valve life may be shortened and system damage may occur if check valves are installed too close to a source of unstable flow. Check valves must be installed at a reasonable distance away from pumps, elbows, expanders, reducers or other similar devices. Sound piping practices dictate a minimum of five (5) times the pipe diameter for general use. Distances between three (3) and five (5) diameters are allowable provided the flow velocity is less than 8 feet per second. Distances less than 3 diameters are not recommended. ..■■..■■■..■■■...■■ won No 0"' ■.■.■®■.■..■■.1/.■.®®■■�■■■■■111 ., i■■�i�■'KWON■���tJ�■<iE■E■■tif���■ta itatitai�t�t•ta�dt•■ OEM■ll��i�i�■fi■����■��■ , ' it■■■i■■■���■■■ti■■�li�■9■��■Biti�El B■■■A�■■.!i■■■ti■■■Btt■■■.fit■ti.■.\�t , .■■■.t■■■■9.■■■9..H . ■■1■■■■w� ■.RF��7■■�iJ11.■��1■!■�1�i�..11�..�111 - Hill ■E�i!■■El11■■!i1■E�i�i■■■111■■11111 on .■..■■■.■m.■■■➢1.■■■B.■■.... _ ■e■■■�i■.11.■.■1®...®■■.11!■■1111 ■MEN ■■■!11■■■111.■■!■■■111■■11111 oil 0 ■i.■■[i.fa.■�■aii♦ Bmom i.■■�9lIi•.ti■■tii.�■ta➢■ti■ti6ta.'■■■ .■■■.■■■ M=, mown ■■.!■■■.■■■■■[♦i1.00l!oo MEN ■ ,,, . sl■■■■■.■■11■■..111 ■■■!■■■!11■■111■■■!■■■!11■■!1111 , - Body Spring ,, 1_ Clapper \ Assembly Bushings (2) y. Hinge Pin - Valve Pipe Hinge Pin Plug (2) C=100 Drain C=120 Connections Size OD Sch.10 Sch.30 Sch.40 Sch.10 Sch.30 Sch.40 2 2.375 10 - 8 14 - 11 50 60.3 3.0 - 2.4 4.3 - 3.4 21h 2.875 14 - 10 20 - 15 65 73.0 4.3 3.0 6.1 - 4.6 3 3.500 17 - 12 23 - 17 80 88.9 5.2 - 3.7 7.0 - 5.2 4 4.500 17 - 13 23 - 18 100 114.3 5.2 - 4.0 7.0 - 5.5 5 5.563 14 - 11 20 - 15 125 141.3 4.3 - 3.4 6.1 - 4.6 6 6.625 23 - 19 33 - 26 150 168.3 7.0 - 5.8 10.1 - 7.9 8 8.625 35 32 30 50 45 43 200 219.1 10.7 9.8 9.1 15.2 13.7 13.1 10 10.750 28 25 24 40 36 34 250 273.1 8.5 76 7.3 12.2 11.0 10.4 12 12.750 31 28 26 44 39 37 300 323.9 9.4 8.5 7.9 13.4 11.9 11.3 Flow Data: The approximate friction losses, based on the Hazen and Williams formula, expressed in equivalent length of pipe is given at left. The friction losses have been calculated on the basis of flow rates typically used with each size valve. Important Note: Check valve life may be shortened and system damage may occur if check valves are installed too close to a source of unstable flow. Check valves must be installed at a reasonable distance away from pumps, elbows, expanders, reducers or other similar devices. Sound piping practices dictate a minimum of five (5) times the pipe diameter for general use. Distances between three (3) and five (5) diameters are allowable provided the flow velocity is less than 8 feet per second. Distances less than 3 diameters are not recommended. ..■■..■■■..■■■...■■ won No 0"' ■.■.■®■.■..■■.1/.■.®®■■�■■■■■111 ., i■■�i�■'KWON■���tJ�■<iE■E■■tif���■ta itatitai�t�t•ta�dt•■ OEM■ll��i�i�■fi■����■��■ , ' it■■■i■■■���■■■ti■■�li�■9■��■Biti�El B■■■A�■■.!i■■■ti■■■Btt■■■.fit■ti.■.\�t , .■■■.t■■■■9.■■■9..H . ■■1■■■■w� ■.RF��7■■�iJ11.■��1■!■�1�i�..11�..�111 - Hill ■E�i!■■El11■■!i1■E�i�i■■■111■■11111 on .■..■■■.■m.■■■➢1.■■■B.■■.... _ ■e■■■�i■.11.■.■1®...®■■.11!■■1111 ■MEN ■■■!11■■■111.■■!■■■111■■11111 oil 0 ■i.■■[i.fa.■�■aii♦ Bmom i.■■�9lIi•.ti■■tii.�■ta➢■ti■ti6ta.'■■■ .■■■.■■■ M=, mown ■■.!■■■.■■■■■[♦i1.00l!oo MEN ■ ,,, . sl■■■■■.■■11■■..111 ■■■!■■■!11■■111■■■!■■■!11■■!1111 , - Material Specifications ♦ Body: Ductile Iron conforming to ASTM A536, Grade 65-45-12. ♦ Coatings: Rust inhibiting paint on exterior - Color: BLACK ♦ Clapper: 2"-5" Type 304 or 302 stainless steel to ASTM A 167 6"-8" Ductile iron conforming to ASTM A 536, Grade 65-45-12 ♦ Clapper Facing: (Specify when ordering) Grade E EPDM -40- to 230'F (40' to 110-C) Service Temperature Range Recommended for water service, dilute acids, alkaline, oil -free air and many chemical services. NOT FOR USE IN PETROLEUM SERVICES. O Seat Ring: Type 304 stainless steel to ASTM A 123, ASTM A 213, ASTM A 312 or ASTM A 269 • Spring: Type 302 stainless steel to ASTM A 313 • Hinge Pin: Type 304 or 302 stainless steel to ASTM A 580 • Hinge Pin Bushings: Sintered bronze to ASTM B 438 ♦ Hinge Pin Plugs and Drain Plugs: Cast iron to ASTM A 126 Class A Several trim combinations are available on request. Page 2of2 Body Spring ,, Clapper \ Assembly Bushings (2) y. Hinge Pin - Hinge Pin Plug (2) Drain Connections Seat Ring Material Specifications ♦ Body: Ductile Iron conforming to ASTM A536, Grade 65-45-12. ♦ Coatings: Rust inhibiting paint on exterior - Color: BLACK ♦ Clapper: 2"-5" Type 304 or 302 stainless steel to ASTM A 167 6"-8" Ductile iron conforming to ASTM A 536, Grade 65-45-12 ♦ Clapper Facing: (Specify when ordering) Grade E EPDM -40- to 230'F (40' to 110-C) Service Temperature Range Recommended for water service, dilute acids, alkaline, oil -free air and many chemical services. NOT FOR USE IN PETROLEUM SERVICES. O Seat Ring: Type 304 stainless steel to ASTM A 123, ASTM A 213, ASTM A 312 or ASTM A 269 • Spring: Type 302 stainless steel to ASTM A 313 • Hinge Pin: Type 304 or 302 stainless steel to ASTM A 580 • Hinge Pin Bushings: Sintered bronze to ASTM B 438 ♦ Hinge Pin Plugs and Drain Plugs: Cast iron to ASTM A 126 Class A Several trim combinations are available on request. Page 2of2 Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: '/2'through 8" Material: Carbon steel Finish: ❑ Galvanized Service: Recommended for suspension of non -insulated stationary pipe line. Maximum Temperature: 650° F Approvals: Complies with Federal Specification A -A -1192A (Type 10) WW -H -171-E (Type 10) and MSS -SP -69 (Type 10). UL and FM Approved (Sizes 3/4"- 8"). Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2* through 3" sizes. Ordering: Specify size, figure number and name. Project: Date: Contractor: Address: Notes 1: Notes 2: Pipe Hanger Submittal Sheet Architech /Engineer: — Phone: Approval Stamp: Fig. 69: Loads (lbs) • Weight (lbs) • Dimensions (in) Pipe Size Max Load Weight Rod D F ASizel3 '/2 0.08 21/4 13/8 3/4 -__ ! ---� 0.09 r---25/1.6'--'-=---12/16 1 - --0.10 ! --- i� ----j 22/16 19/76 7/8 300 11/4 ii 1 0.1-0 1 1 25/8 13/4--- i - 0.10j 3/8 - 23/4 17/8 - 1'/4 2 0.11 3 ---------------+---------- 1/4 j 23/8 11/8 4 23/4 15/16 21/2 0.20 i -- -I 525 r - - - - ---- --- *- ----- 3- 0.20 i 43/8 31/8 13/8 65 - I 0.30 1 4 1/16 + i 3 13/1 6 !4 5 -- - 0.53 �- - -r - - 55/16 43/8 19/16 6 1,000 1 ._..__.._.__....... 0.80 - - 1/2 -..__._._........._; 67/16 51/2 23/16 8 1.00 8 7 211/16 Pipe Hanger Submittal Sheet Architech /Engineer: — Phone: Approval Stamp: Fig. 92 Universal C-type Clamp (Standard Throat) Size Range: 3/8 and 1/2" Material: Ductile iron, hardened steel cup point set screw and locknut. Finish: 0 Plain or 0 Galvanized Service: Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4". Approvals: Complies with Federal Specification A -A -1192A (Type 19 & 23) WW -H -171-E (Type 23) and MSS -SP -69 (Type 19 & 23). UL, FM and ULC Approved. How to size: Size of clamp is determined by size of rod to be used. Installation: Follow recommended set screw torque values per MSS -SP -69 (See table on page PH -212) Features: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup -pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. Ordering: Specify rod size, figure number, name of clamp and finish. JAM - SET SCREW 15 f AT LEAST ONE FULL THREAD OF ROD MUST BEEXPOSED D � BOOY CASTING A Fig. 92: Load (lbs) • Weight (lbs) • Dimensions (in) Rod Size A Set Screw Size Max Loads Weight C D E ' F G H Top Bottom 3/8 3/8 500 250 0.34 15/16 i 1 9/16 9/16 1 13/16 i 3/8 i 1/2 1/2 1/2 950 76() 0.63 1 13/8 -+- 113/1623/32 11/16 7/16 23/32 ■ Maximum temperature of 450° F Project: Date: Contractor: Address: Notes 1: Notes 2: Pipe Hanger Submittal Sheet Architech / Engineer: . Phone: Approval Stamp: MODEL 1011 TEWMDRMN. F MODEL 1011 (UL LISTED/FM APPROVED) BRONZE BALL VALVE MODEL 7000 (UL LISTED/FM APPROVED) PRESSURE RELIEF VALVE FACTORY SET AT 175 PSI WITH OTHER SETTINGS AVAILABLE. FRONT VIEW - MODEL 1011 INLET A DRAIN PLAN VIEW From the February 1, 1999 Edition of NFPA 13: Chapter 4-1.2 Requires ALL GRIDDED SYSTEMS be provided with a relief valves Chapter 5-14.1.2.3 Requires a relief valve be installed downstream of all pressure -reducing valves ORIFICE SIZES AVAILABLE -3/8, 7/16, 1/2, 17/32, ELO(5/8)•, ESFR(3/4)' DIMENSIONS - INCHES JOB NAME: _ ARCHITECT: _ ENGINEER: _ CONTRACTOR: OVERALL LENGTH 100 Quaker Lane Malvern, PA 19355 USA Telephone: (610) 240-4900 ow Fax: (610) 240-4906 www.testandrain.com 1011 MADE IN U.S.A. 1011 SIZE A B C D E F G I H MATERIAL LIST 3/4 1 7 9/16" 1 1/2' 2 3/16" 3 5/8" 3 3/81 1 13/15 � 4 9/16" 63/8 � 191.30mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm PART: MATERIAL: 11 1 7 9/15 r 1 1/2 " 2 3/16" 3 5/8" 3 3/51 1 13/16" 4 9/i6" 6 3/8" 191.30mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm HANDLE STEEL 1/411 7 15/16" 1 11/15" 2 9/18' 4 1/4" 3 5/16' 1 15/16" 5 9j16" 5 1/2" BA ROD BRASS 201 mm 42.70mm I 65.36mm I 108.36mm I 82.84mm I 50.89mm 141.39mm 192.28mm L BODY C.PBRONZE BRONZE 1 1/2' 8 15/16" 1 13/151 3 1/4" 5 1/16" 3 7/5" 2 5/5" 8 1/41' 107/8 t VLVE SEAT IMPREGNATED TEFLON 226.68mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm INDICATOR PLATE STEEL 2 8 15/15 1 13/15 3 1/4"5 1/15 3 7/5� 2 5/e', 8 1/4 � 10 7 5' RELIEF VALVE BRONZE 226.68mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm BYPASS TUBING BYPAS S BRASS NYLOBRAID Available on 1 1/4' to 2" size units only. UL LISTING EX4019(N) & EX4533(N) . JOB NAME: _ ARCHITECT: _ ENGINEER: _ CONTRACTOR: AGF MANUFACTURING COMPANY 100 Quaker Lane Malvern, PA 19355 USA Telephone: (610) 240-4900 ow Fax: (610) 240-4906 www.testandrain.com MADE IN U.S.A. JOB NAME: _ ARCHITECT: _ ENGINEER: _ CONTRACTOR: �Mw United Ball Valves are designed and have been tested for applications from low pressure cold water to 200 lbs. of steam pressure. They provide a tight seal through this full range of conditions. They are ideally suited where quick shut off (1 /4 turn) is necessary. Ball Valves are suitable for service as indicator valves. The "on-off" status can be determined by handle position. All Ball Valves feature a milled stem and external nut to connect lever to stem for strength and alignment. Meets Federal Specification WW -V -35-B, Type 2, Class A, Style 3. 200 lbs. WSP 400 lbs. WOG 100% Pressure Tested Plated Lever with Vinyl Hand Grip Standard Packing Chamber Blow Out Proof Stem Non -Asbestos Packing 1/4 - 1/2 Full Flow 3/4 - 2" Large Port Diameters Body Material: Bronze Conforming to ASTM B62 Bronze Bali 80SS Ball Valve with Stainless Steel Ball 8OWBC Bali Valve with Chromed Bronze Ball SIZE A B C D E F SHIP WT. (Ibs.) QUAN. PER CTN. 80 80 80 1/4" 3/8 1 55/64" .59/64" 15/16" 1 35/64" 3 5/16" .52 12 3/8" 3/8 1 55/64" 59/64" 15/16" 1 35/64" 3 5/16" .52 12 1/2" 1/2 211/64" 1 1/16" 1 7/64" 2 9/32" 415/64" .78 12 3/4" 5/8, 2 33/64" 1 13/64" 1 5/16" 2 3/8" 4 15/64" .98 12 1" 13116 3 17/64" 1 43/64" 1 19/32" 2 35/64" 4 15/64" 1.59 6 11/4" 1 331/64." 123/32" 149/64" 3 3/16" 515/32" 2.47 4. 1 1/2" 1 1/4 3 31 /32" 1 61/64" 2 1/64" 3 3/8" 5 15/32" 3.50 4 2" 1 1/2 4 13132" 2 9/64" 2 17/64" 3 9/16" 5 15/32" 5.00 2 MARINE SERVICE United Ball Valves are available for marine service with brass lever and brass nut as part No. 80BLH in sizes 1/2-2" and as shown at right with brass side outlet plug for use as a Seacock as part No. 80BRS size 1/2-1 112". For Replacement Seat Rings See Page 52 UL ULC/Canadian Models Models W FD20 W FD20A WFD25 WFD25A W FD30 W FD30A W FD30-2 W FD30-2A WFD35 WFD35A W FD40 W FD40A WFD50 WFD50A W FD60 W FD60A WFD80 WFD80A Replacement Parts A3008-00 Retard Mechanism A77-01-02 Terminal Block 546-7000 Cover Tamper Switch Kit WFDW Cover Wrench WFDN4 Replacement gasket kit Product Overview New WFD30-2 models install in 2" System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, hole sizes sizes 2" through 8", and can be mounted in a vertical or horizontal position. UL models are NEMA 4 rated Robust Construction. The WFD series consists of a rugged, NEMA 4 rated Sealed retard mechanism assures that enclosure. Designed for both indoor and outdoor use, the WFD series operates the retard is not contaminated by dust across a wide temperature range, from 32°F to 120°F. and dirt when the cover is removed sealed design is immune to dust and other contaminants. both alarm panel and local bell Reliable Performance. UL listed models are equipped with tamper resistant Visual switch activation permits cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form Q installer to accurately set retard under synchronized switches are enclosed in a durable terminal block to assure noisy conditions reliable performance. Rugged, dual SPDT switches are enclosed in a durable terminal block False Alarm Immunity. The WFD series incorporates a mechanical retard fea- ture, which minimizes the risk of false alarm due to pressure surges or air Accommodates up to 12 AWG wire trapped in the sprinkler system. In addition, the mechanical retard's unique 100% synchronization activates sealed design is immune to dust and other contaminants. both alarm panel and local bell Simplified Operation. The WFD series is designed to simplify installation. Two simultaneously conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field -replaceable. uL FM O MEA X APPROVED LISTED ED approved Engineering Specifications Vane -type waterflow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6" from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24" from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2" - 8" pipes. The detector shall respond to waterfiow in the specified direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mech- anism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or out- door use. Standard Specifications Static Pressure Rating 450 PSI Triggering Threshold Bandwidth (Flow Rate) 4-10 GPM Maximum Surge 18 Feet Per Second (FPS) Compatible Pipe: Steel water pipe, schedule 10 through 40 Contact Ratings Two sets of SPDT (Form C) 10.0 A, 1/2 HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Overall Dimensions Installed Ordering Information Conduit Entrances Two openings for 1/2" conduit. One open, one knock -out type Operating Temperature Range 32°F to 120°F (0°C to 49°C) Enclosure Rating': NEMA 4 - suitable for indoor/outdoor use Cover Tamper Switch Standard with ULC models Optional for UL models, part no. 546-7000 Shipping Weight W FD20: 4.2 lbs. W FD25: 4.3 lbs. W FD30: 4.5 lbs. W FD30-2: 4.5 lbs. W FD35: 4.7 lbs. WFD40: 5.2 lbs. W FD50: 6.3 lbs. WFD60: 6.8 lbs. W FD80: 7.5 lbs. Service Use Automatic Sprinkler: NFPA-13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Warranty 3 Years U.S. Patent Numbers 3,845,259 4.782,333 5,213,205 U_ Model Numbers U_C/Canadian Model Numbers Pipe Size I Hole Size Part Number Description WFD20 WFD20A 2" 11/4" A3008-00 Retard mechanism WFD25 WFD25A 21/2" 11/4 A77-01-02 Terminal block WFD30 WFD30A 3" 11/;' 546-7000 Tamper proof switch kit WFD30-2* WFD30-2A 3" 2" WFDW Tamer proof wrench for cover WFD35 WFD35A 31/2" 11/4" WFDN4 Gasket kit WFD40 WFD40A 4" 2" WFD50 WFD50A 5" 2" WFD60 WFD60A 6" 2" WFD80 WFD80A 8" 2" *UL listed only. System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800-SENSOR2 X: 630/377-6495 )ocuments On Demand: �1-800-736-7672 x3 Web: www.systemsensor.com System Sensor In Canada System Sensor In China System Sensor In the Far East System Sensor In India Ph: 905.812.0767 Ph: + 86.29.524.6253 Ph: + 852.21919003 Ph: + 91.11.558.2119 Fx: 905.812.0771 Fx: + 86.29.524.6259 Fx: + 852.27366580 Fx: + 91.11.567.6815 System Sensor In Europe System Sensor In Singapore System Sensor In Australia Ph: + 44.1403.276500 Ph: + 65.273.2230 Ph: + 613.54.281.142 Fx: + 44.1403.276501 Fx: + 65.273.2610 Fx: + 613.54.281.172 O 1999 System Sensor. The company reserves the right to change product specifications without notice. A05-18006.6/ 00(5N)•8545 1'L is ng fit Ire ;ts for ;e. on ies )ut Ich be I® OF 2 BELLS POTTER PBA -AC & PBD -DC ® The Symbol o/ Protection. j UL Listed, FM Approved 6" BELL SHOWN Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40' to 150°F (-40' to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use '0 or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZECURRENT INCHES (mm) VOLTAGE MODEL NO. STOCK NO. (MAX -)AT TYPICAL dB 10 FT. (3-)(2) MINIMUM d8 AT 10 FT. (3-)(1) 6(150) 12VDC PBD126 1706012 .12A 85 76 6 (200) 12VDC PBD128 1708012 .12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6 (150) 24VDC PBD246 1706024 .06A 87 76 8(200) 24VDC PBD248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10(250) 24VAC PBA2410 1810024 -17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10(250) 120VAC PBA12010 1810120 .05A 99 85 Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV P PAGE 1 OF 2 MFG. #15400776 - 3/99 135 N FIG.1 BELLS 10" k.2 0) 1-1- - g" (200) 6^ I (150) i l7 —`�T- - 2 11/16"� 1 (68) DWG. #776-1 FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED I/2'CONDUITENTRANCE DWG. #776-2 3 3/8- (86) 4 1/4" (108) FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) RED (OUT) rHITE (IN) WHITE (OUT) -� 0 0 F5 FROM CONTROL PANEL. TO NExT BELL TROY CONTROL PANEL O! OR ENO -OF -LIVE OR PRECEDING BELL RESISTOR PRECED04 BELL BUCK (N) BLACK (OUT) BLACK (N) G BLACK (OUT) AC U CAUT&k WEN CLECTRIGTL SUPERVISION IS REOWED USE N AND OJT LUGS AS SHOWN. WHEN ELECTRICAL SUPERVISION 6 REOARCD USE N AND OUT LEADS AS SHOWN, NOTES; 1. OBSERVE POLARITY TO RING D -C. BELLS, 2. RED NARES POSITIVE (+) .i BLACK WIRES NEGATIVE (-) DWG. ]776-3 5' (127) NOTES, 1, WHEN USING A,C, BELLS, TERLAINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2, ENO -OF -UNE RESISTOR IS NOT REOVIRED ON A.C, BELLS, INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2.4m) from the floor or as close to the ceiling as possible. 2. Removethegong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 'i. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV P PAGE 2 OF 2 MFG. #5400776 - 3/99 136 119 1JV ,. A e c 1 E D F 9 p 6 FM L 11 -V,'5,6� -I W12 1*1 30° I 7s EXPOSED STANDPIPE/AUTO SPRINKLER Elkhart 156 brass wall type siamese connection has two individual clapper valves, plugs and chains. Escutcheon lettered "Standpipe," Auto-Sprk," or "Standpipe and Auto-Spkr" Finish: Polished brass. Optional: Polished chrome plated. Specify size and thread: 21/2" x 21/2" x 4" 21/2" x 21/2" x 6" Size A B C D E F 21/2 x 21/2 x 4 117/8 65/e 11 Y,e 85/s 12/4 49/16 21/2 x 21/2 x 6 117/8 65/s 111/16 1073/16 12/4 61/1e (Dimensions in inches) Elkhart 11 Siamese -Single Clapper, lightweight, cast brass lettered "Auto-Spkr." One swinging brass clapper valve. Complete with brass swivels. Threads to local fire department specifications. Plugs and chains available at extra cost. Finish: Cast brass. Specify thread: 21/2" x 21/2" x 4" Elkhart 18 Three -Way Standpipe Siamese. Independent drop clap- per valves. Plugs and chains available at extra cost. Threads to local fire department specifications. Finish: Body painted red, cast brass trim. Optional: Polished brass or polished chrome plated trim. Specify thread: 21/2" x 21/2" x 21/2" x 6" Elkhart 12 Two -Way Standpipe Siamese. Cast brass standpipe or sprinkler siamese. Two individual drop clapper valves. Plugs and chains available at extra cost. Specify lettering: "Standpipe" or "Auto-Spkr" Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plated. Specify size and thead: 21/2" x 21/2" x 4" 21/2" x 21/2" x 6" Size A B C 21/2 x 21/2 x 479/16 115/16 51/4 21/2 x 21/2 x 6 10 11 Yz 71/2 (Dimensions in inches) Elkhart 10 90° Two -Way Siamese. Independent drop clapper valves. Plugs and chains available at extra cost. Specify lettering: "Standpipe" or "Auto-Spkr." Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plate. Specify size and thead: 21/2' x 21/2" x 4" 2112" x 21/2" x 6" Elkhart 29 90° Three -Way Sidewalk Siamese. Cast brass with inde- pendent drop clapper valves. Plugs and chains available at extra cost. Threads to local fire department specifications. Finish: Cast brass. Optional: Polished brass or polished chrome plated. Specify thread: 2112"x21/2"x2'/2"x6" q