Loading...
HomeMy WebLinkAbout2418 S Bay AvePermit # : O-5 - L Job Address: Description of Work: 17�o Historic District: u rp Zon CITY OF SANFORD PERMIT APPLICATION Date: / 0- S- O % ,4 r ,, , o -"_la - - I O vw—e p : Value of Work: $ d r Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential _A� Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Commercial Occupancy Type: Residential __�_ Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: (Attach Proof of Ownership & Legal Description) Owners Name & Address: C U L Ole, l/fTn/Ge T� Y� Ly P 1,�-IV / ep' %3v5;2 ,,4 ✓c. 5' V, c' f ! Phone: �' C) 7� 3.zA- Contractor Name & Address: Phone & Fax: Bonding Company: Address: Mortgage Lender: _ Address: Architect/Engineer Address: State License Number: Contact Person: Phone: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is erification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. ,)r 04r, IV c� /o.,. Signature of Owner/Agent Date Signature of Contractor/Agent Date P t Owner/Agent's Name Print Contractor/Agent's Name /v -6-v v Sig tore o Date Signature of Notary -State of Florida Date DEBBIE BLANTON MY COMMISSION # DD 188491 Y✓1 N en is rersort81vy4+cneu�ur lO NIC or �(o u Yd ID FL Notary Discount A-- Cc l) 0 APPLICATION APPROVED BY: Bld i I oning: (Initial & Date) Special Conditions: Contractor/Agent is _ Personally Known to Me or Produced ID Utilities: FD: (Initial & Date) (Initial & Date) (Initial & Date) 'COU/-j- NOTICE OF COMMENCEMENT Permit No. - Tax Folio No. State of Florida County of Seminole The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property: (legal description of the property and street address if available) 2. General description oViinprovement: 3> Owner information ��-, a. Name and address 2> C vV-7� 7% ;-L O/ %i �, , ✓,� _(�gt r f' . b. Interest in property1 ILII !I !! II! i! fl 11111111 If I! III !I !i I!I! II61111161 illi c. Name and address of fee simple titleholder (if other than Owner) MARYANNE MORE, r- EFTS Of C1FX111T WUW 4. Contractor SEMINOLE COI AITY a. Name and address r%�� BK 05472 PG 1521 CLERK"S # L2004154212 b. Phone number 10:47129 AN Fax nuWRYING 5. Surety FEES W. a@ RECORDED BY 6 O'Kelley a. Name and address b. Phone number - Fax number __ , � c. Amount of bond 6. Lender / IW a. Name and address A{ 5 b. Phone number Fax number 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: // a. Name and address ✓�qn/t /"o ;, /U% b. Phone number Vo j_, ;�.�_- S - Fax number 8. In addition to himself or herself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. a. Phone number Fax number Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) r' • Signature of On r Sworn to (or affirmed) and subscribed before me this 61' day of 0 C -7- C_ - C_ j v 10 Personally Known OR Produced Identification . i' Type of Identification Produced Q -_G,• "��"'° a--S�--36 -� Signatur o Pc,State of Flori Commission Expires:DEPUTY CL R UE L r „t rl C n 2000 ,by THIS INSTRUMENT PREPARED BY. NAME ADDR.4�� 1�'ra�u cri 2� 7 y'A�� 4+-.�C� "s M'�'' .w o.r CITY OYSANFORD BUILDING DIVISION OWNER/BUILDER AFFIDAVIT CONSTRUCTION CONTRACTING Owners of property when acting as their own contractor and providing direct, onsite supenlision themselves of all work not performed by licensed contractors, when building or improving farm outbuildings or one -family or two-family residences on such property for the occupancy or use of such owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such structure by the owner -builder within 1 year after completion of same creates a presumption that the construction was undertaken for purposes of sale or lease. This subsection does not exempt any person who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The owner may not delegate the owner's responsibility to directly supervise all work to any other person unless that person is registered or certified under this part and the work being performed is within the scope of that person's license. For the purposes of this subsection, the term "owners of property" includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this subsection, an owner must personally appear and sign the building permit application. State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your ovmi contractor with certain restrictions even though you do not have a license. You must provide direct, onsite supervision of the construction yourself. You may build or improve a one -family or two-family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume tliat you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I, , do hereby state that I am qualified and capable of performing the requested construction involved with the permit application filed. I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work allowed by law on the permitted structure. A _ Owner/Builder Signatur Date Print OwnerBuilder Name / &,/, /o-( Si e of No —State of Florida Date W DEBBIE BLANTON 0 e M� a V l ria°V8� or has E 0 3/ a E PURLIN BEARING LEG Specifications: For use on Slopes 3/12 or Greater! 36" Net Coverage 38" Overall Width Gauge Finishes Thickness ASTM & Grade Specifications 29 Galvanized .0142 ASTM A-653 Grade 80 Structural Steel 29 ' PTD Galvanized .0142 ASTM A-653 Grade 80 Structural Steel 26 '* PTD Galvanized .0185 ASTM A-653 Grade 80 Structural Steel 29 Acrylic Galvalume .0142 ASTM A-792 AZ55 Grade 80 Structural Steel 26 Acrylic Galvalume .0185 ASTM A-792 AZ55 Grade 80 Structural Steel * RED, WHITE, BLUE, GRAY, HUNTER GREEN, STONE, BROWN; CHARCOAL and TAN. ** WHITE and HUNTER GREEN MILLENNIUM METALS OFFERS A LIMITED 25 YEAR WARRANTY ON PAINTED PANELS AND A LIMITED 20 YEAR WARRANTY ON MILL FINISHED GALVALUME PANELS. CONSULT YOUR DISTRIBUTOR ON REQUESTING WARRANTY. A. E. J -C1: STD J -CHANNEL CORNER POST WINDOW WALL GIRT RIB PANEL 9 x 1-i/2 WOOD FASTENER 9" OC PENETRATING 21/16 —IJIII OUTSIDE RIB CLOSURE 1 P . 7/ 2 GR4: STD GABLE TRIM #9 x 1-1/2 WOOD /FASTENER OC THOUGH DOUBLE STICK TAPE 5/B 2 / • P 7/6 31/4 C. PC: POST COVER A B B PC #1 3-1/2 1-1/2 A PC #2 5-1/2 1-1/2 PC #3 7 1-1/ PC#4 9 1-1/2 PC #5 3 3 P B A TC1: TRACK COVER RIB PANEL 9 x 1-1/2 WOOD FASTENER I 9' OCPENETRATING I OUTSIDE RIB CLOSURE I1�!I!I ! FF1/2SDOOR EF3: 6" STD ROOF EDGE •9 x 1- 12 WOOD FASTENER • RIB PANEL 9^ OC PENETRATING INSIDE RIB CLOSURE Plywood i Decking Min 1" overhang at Eave area P, p EDI 21/I2 EF3 H. ENDWALL FLASHING G ■ RC2: FLAT RIDGE CAP •9 x 1-1/2 WOOD FASTENER 9' OC PENETRATING PEAK OUTSIDE RIB CLOSURE MAX DISTANCE RIB PANEL 4 �• 11/2 STD'112 PITCH 7/6 K. SIDEWALL FLASHING I I DOOR TRACK COVER E■ STD ROOF EDGE C. POST COVER DA1: DOUBLE ANGLE '9 x 1-1/2 WOOD FASTENER RIB PANEL ,P 21/16 7/ RIB PANEL 11/4 B. GABLE 0. DI 1 E////v N■ BASE DRIP EW1: ENDWALL FLASHING SUGGEST COUNTER FLASHING WITH 1-1/2 WOOD FASTENER '9 x 1-1/2 WOOD FASTENER 9" OC PENETRATING RIB OUTSIDE CLOSURE i — 33/16 P MUST SPECIFY 4 1 PITCH ASSOCIATED WITH ! 316 3/ 4 ENDWALL FLASHING RIB PANEL 11/16 TRANSITIt ANGLE C BITCH 212 312 412 5112"— 6112 I LLENNI J METALS, INC. Shipping: 1333 Haines Street Exp., Jacksonville, FL 32202 • Mailing: aE VERSION, ANGLE 152' 143' 134° 127' T I. RC6: VENTED RIDGE '9 X 1-1/2 WOOD FASTENER 9" OC PENETRATING RIB OUTSIDE CLOSURE i OPfN, MAX DISTANCE RIB PANEL 1- /z' IS 3/8 P A COBRA PROFILE VENT SIDEVIEW 100TD'/,z PITCH SW1: SIDEWALL FLASHING - - SIDING NOTE '9 x 1-1/2 WOOD FAST 9 -OC PENETRATING UNIVERSAL CLOSURE UNIVERSAL 3 3/16 P CLOSURE 90° 1/16 31/2 5/8 ENDWALL IVERSION ANGLE 99° 104° 108° 113° 117° J. TF1: TRANSITION FLASHING -- RIB PANEL '9 x 1-1/2 WOOD FAST FASTENER 9" OC 1 j MINIMUM 3• PENETRATING RIB _ OUTSIDE CLOSURE RIB PANEL A MUST SPECIFY BOTH PITCHES ASSOCIATED WITH TRANSITION FLASHING 61/2 L. IS1: INSIDE CORNER i, � 1 1 1/ SIDING APPLICATI ON F8yl6_ - 46/16 M. PV1: PREFORMED VALLEY A w RIB PANEL TWO STRIPS OF OVER BUTYL I� TAPE 'I i -- BUTYL TAPE NOTE: STOP �PANEL 7' MIN. FROM BREAK FASTEN PERFORMED VALLEY 9' OC 11 \ / 1 \ v`� 121/4 PV1 PV2 N. BD1: BASE DRIP DC1: DRIP CAP •9 x 1-1/2 WOOD / FASTENER 9" OC PENETRATING OUTSIDE RIB CLOSURE u�--- RIB PANEL SIDING APPLICATION WINDOW � p OR DOOR 273/16 OPENING 75/6 1/ CRT: RAKE/CORNER 11/16 27/16 3/4 B 154, 1526 University Blvd. W., Jacksonville, FL 32217 • Office: 904-358-8366 • Watts: 877-358-7663 • Fax: 904-358-8285 *--RIB PANEL FOR USE AS SIDING 4- --'9 x 1-1/2 WOOD FASTENER / e- SIDING APPLICATION r p 2 � /8 CONCRETE SLAB 11 /4 DC1: DRIP CAP •9 x 1-1/2 WOOD / FASTENER 9" OC PENETRATING OUTSIDE RIB CLOSURE u�--- RIB PANEL SIDING APPLICATION WINDOW � p OR DOOR 273/16 OPENING 75/6 1/ CRT: RAKE/CORNER 11/16 27/16 3/4 B 154, 1526 University Blvd. W., Jacksonville, FL 32217 • Office: 904-358-8366 • Watts: 877-358-7663 • Fax: 904-358-8285 RIB PANEL INSTALLATION GUIDE SIDE LAP DETAIL PREVAILING WIND ANTI SIPHON CHANNEL FASTENER PURLIN / BEARING RIB DETAIL A •1 - RIB PANEL FASTENING RECOMMENDATIONS I NOTE: NAIL ATTACHMENTS IS THROUGH MAJOR RIBS. DETAIL B FIELD PURLIN- - - - - - - - - - - ATTACHMENT #9 x 1/12 ' 1 WOOD FASTENER -� o • • • DETAIL C (EAVES, RIDGES & ENDLAPS) #9 x 1-1/2 WOOD FASTENER DETAIL B & C Millennium Metals recommends the use of a solid deck with felt on residential applications. This recommendation is made to help eliminate condensation issues. Battens are optional with solid deck applications or over existing shingles. Note shingles cannot be battened over if more than two layers exist. Roof decking integrity should be checked to insure adequate pull out in any reroofing application. Battens should be 1 x 3 yellow pine spaced on 16" centers. Open purlin applications on commercial or agricultural applications should be spaced no more than 24" on center. ROOF APPLICATION: Step 1: Make sure the deck is level and square. Step 2: Install Eave Drips/Roof Edge and Valleys according to details. Remember to use inside closure strips between Eave and Panel to eliminate water infiltration. Trim should be fastened 7" on center. Step 3: Panel placement should begin on the Gable End opposite of the Prevailing Wind. Starter Edge should be the Lap Edge. (Opposite of Purlin Bearing Leg) after lying first panel check for squareness panel 2 should be lapped over Purlin Bearing Leg of panel 1 with the Lap Edge. A minimum 1" overhang is recommended at the Eave. Alternative method of panel placement may begin in the center of the roof. Often this method is used when the area covered is not disable by 3' or traditional placement allows for a Pipe Flashing to occur in a Side Lap. Endlaps must be a minimum of 12" and two strips of Butyl Sealant is recommended 8" on uphill side of lap to keep watertight. Step 4: Fasten panel according to Detail C or D depending on the area of application. Detail D shows additional screws to be spaced on each side of major Ribs for all Eaves, Ridges and Endlaps. Step 5: Any field cutting must be done with metal nibblers, metal snips or blades designed for metal cutting. No cutting should be done on the roof, as it will cause iron shavings to be spread and adhere to roof panels. Proper cutting should be done exposed panel finished side down. Step 7: Install the remaining accessories such as Pipe Boots, Rib Profile Vent, Ridge Cap and Gable Flashing. Butyl Sealant, Caulking and Closures are necessary to maintain watertight seals. Inspect screw fasteners to insure that they are installed properly. (See Detail D) Step 8: Field clean the roof surface with broom to be sure any iron shavings are removed. PITCH ALERT!!! RIB PANEL REQUIRES A MINIMUM 3/12 PITCH TO MAINTAIN WATER DRAINAGE. THIS PRODUCT IS CONSIDERED STRUCTURAL HOWEVER IT IS NOT SAFE TO WALK ON. ' ATTENTION INSTALLERN! WHEN USING FASTENERS TO PENETRATE STEEL SHEETS THE IRON PARTICLES TEND TO GO AIRBORNE AND SETTLE ON THE SHEET. IT IS NECESSARY TO REMOVE THESE PARTICLES TO PREVENT EMBEDMENT AND RUST MARKS. FASTENERS #9 X 1-'/2 WOOD TYPE CORRECT TOO LOOSE TOO TIGHT EDPM MATERIAL EDPM NOT AT EDPM IS VISIBLE AT VISIBLE JOINT. PANNED AND IS WASHER. NOTENOUGH PROTRUDING FASTENER IS COMPRESSION BEYOND EDGE PROPERTY TO MAKE A SEAL. OF FASTENER. INSTALLED. DETAIL D I ENGINEERING CONSIDERATIONS I Code requirements vary from area to area and job type as well as roof configuration. Job specific engineering is available for a nominal fee by a structural engineer. The engineering is not a service provided by Millennium Metals and we accept no liability as to contracted work between'parties. Please consult your local building code for proper procedures so we may assist you with your application. MILLENNIUM METALS INC. 1333 HAINES STREET EXP. JACKSONVILLE, FL 32202 PHONE: 904-358-8366 • WATTS: 1-877-358-7663 • FAX: 904-358-8285