Loading...
HomeMy WebLinkAbout119 Rabun Ct (5)Wit®5- Job Address: IIi Description of Work: Historic District: J CITY OF SANFORD PERMIT APPLICATION Vo'LJ i2 Date: _ Zoning: Value of Work: S f Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool 1—,- Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gras Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of cSttories: # of Dwelling Units: Flood Zone (FEMA form required for other than X) Parcel #: ! )4L) 3 J f7 • 000U- 033C) Attach Proof of Ownership &Legal Description) Owners Name & Address: V 4 Lb1-1(_ 1. ill L t tx. S V KI off( 64 LL 1 l 9 2A i3U N r T- Ply (:b 3 Phone: Contractor Name & Address: FA-Q R- co,-, Phone & Fart 014• (1-1 (c , -D13CAD Bonding Company:. y) (V.)- Address: Mortgage Lender: _ Address: Architect/Engineer: Address: lr4t* ctQ-+ O°r Application is herebymade to obtain a " `' permit to do the ivet grid installations as indicated. 1 certify that no wodLoziWallation has commenced prior to theissuanceofapermitandthatallworstwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable lawn i Mil.+.tingconstructionandzoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOI IT, 1• tcYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the pnhlic mcofds of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of.kxrmrt is venfica n/ tion that 1 will notify the owner of the property of the requireme is of Florida Lien Law, FS 7 Signature of Owner/Agent entggDate r azure of Conaactor/Agent at c7i+' a m tlR.CZ Print Owner r en ' Name % Print C or gent' me o atur f nary -State of Florida Date aTu of otary-State of Florida Date 4p. V Carmen Vellonerr nn Carmen Vellone C wneellrRBPersonally Known to Me ormy rExpires F#pry "etQ20pg ! R nally Known to Me or Nad F$dFiiaty I 2008 w APPLICATIONAPPROVED BY: Bldg: (j 2-'' 1 ,"5 Zoning: Utilities: FD: Initial & Date) ( Initial & Date) (Initial & Date) (Initial & Date) Special Conditions: yeh i l-- i+.. 1 /KVl , i \ AT - of Central Florida, Inc. LIMITED POWER OF ATTORNEY 1123 Seminola Boulevard Casselberry, FL 32707 Office: (407) 696-2300 Fax: (407) 696-2360 I hereby name and appoint -PM72c CA — to by my lawful attorney in fact to act for me and apply to CO-C( t5o'-' far -O2p for a permit for work to be performed at: and to sign my name and do all things necessary to this appointment. STATE OF FLORIDA COUNTY OF SEMINOLE The fore ping instrument was acknowledged before me this I.S day of 200Sby James M. Burke, who is personally known to me. Apr h Comm Vakm ota ublic, State of Florida . Mycomm**onDD289619 Exom February 10. 2008 BE SURE ... Check with the POOL PROS i Permit # Job Address: fic r'r'47 U Description of Work: pwiL CITY OF SANFORD PERMIT APPLICATION r Date: Historic District: Zoning: Value of Work: $ W Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service TemporaryPole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/ New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than x) Parcel #: U -T - Owners Name & Address: l . Attach Proof of Ownership & Legal Description) Phone: Contractor Name & Q* Adddreesss-: Q1 F C ct p V,i A-t__ l\ s Fi t M"R.Q 1 y NJIMS 'L 1 Z \ State License Number: C C - 1 3 601 %gn 71P Phone & Fax: Contact Person: Phone: Bonding Company: Address: Mortgage Lender: Address: Architect/ Engineer: Phone: Address: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and . AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as w er anagement districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the Signature of Owner/Agent Print Owner/Agent's Name Signature of Notary -State of Florida Owner/ Agent is _ Personally Known to Me or Produced ID Date Date Signature Law, FS Date Co actor/Agent i onally Known to Me or Produced ID_L APPLICATION APPROVED BY: Bldgl,J 2 * — 105 Zoning: Initial & Date) (Initial & Date) Special Conditions: Utilities: FD: Initial & Date) (Initial & Date) LIMITED POWER OF ATTORNEY Date: % " ) 37 0 I hereby name and appoint &tZ eZ4- RZV O of Florida Pools to be my lawful attorney in fact to act for me and apply to (A-, &.-- &40,ur for an electrical permit for work to be performed at a residence at a location described as: Section 4 Township 0-0 Range 3 Lot 3 Block Subdivision S P+*VD &44 t 9 P-t- Aj C-,-cn. Street Address City or County Zip Code A-t-c Cz g'v voyog t Owner of Property Address Telephone And to sign my name and do all things necessary to this appointment. Brian Keith Miller EC-13001686 Printed name of active Certificate Holder (Master Electrician) State Registration or Certificate Number Signature of license holder n N Diane T Sawyer j. My Comrr4n= DD143235 aExpires August Is. 2005 Acknowledged: Sworn to me and subscribed before me this 24th day of June ,2004 ublic, State of Florida Seminole County Property Appraiser Get Information by Parcel Number Page 1 of I htOAVIDJOHNSON. Cf-A. ASA r S PROPERTY Z RABUN CT 1 APPRAISER 0 SEMINOLE COUNTY F-L. D WAL 1 101 E. FIRST ST m eayC_'+n Mr pSANFORD ,FL32771-1468 407-665-7506 r I ' IF • I 2005 WORKING VALUE SUMMARY GENERAL Value Method: Market 07-20-31-507-0000- Number of Buildings: 1 Parcel Id: 0330 Tax District: S1-SANFORD Depreciated Bldg Value: $65,370 Owner: SUNDVALL HAROLD R Exemptions: 00- Depreciated EXFT Value: $208 ALICE G HOMESTEAD Land Value (Market): $15,700 Address: 119 RABUN CT Land Value Ag: $0 City,State,ZipCode: SANFORD FL 32773 Just/Market Value: $81,278 Property Address: 119 RABUN CT SANFORD 32773 Assessed Value (SOH): $59,561 Subdivision Name: SANORA SOUTH UNIT 1 Exempt Value: $25,000 Dor: 01-SINGLE FAMILY Taxable Value: $34,561 Tax Estimator 2004 VALUE SUMMARY SALES Tax Value(without SOH): $1,161 Deed Date Book Page Amount Vac/Imp 2004 Tax Bill Amount: $686 WARRANTY DEED 01/1976 01108 0342 $27,300 Improved Save Our Homes (SOH) Savings: $475 2004 Taxable Value: $33,450 Find Comparable Sales within this Subdivision DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS LAND LEGAL DESCRIPTION PLAT Land Assess Method Frontage Depth Land Units Unit Price Land Value LEG LOT 33 SANORA SOUTH UNIT 1 PB 19 LOT 0 0 1.000 15,700.00 $15,700 PGS 76 & 77 BUILDING INFORMATION Bid Num Bid Type Year Bit Fixtures Base SF Gross SF Heated SF Ext Wall Bid Value Est. Cost New 1 SINGLE FAMILY 1976 5 1,064 1,516 1,064 CONC BLOCK $65,370 $74,284 Appendage / Sgft OPEN PORCH FINISHED / 88 Appendage / Sgft ENCLOSED PORCH FINISHED / 364 EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New ALUM PORCH W/CONC FL 1980 80 $208 $520 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www. scpafl.org/pls/web/re_web. seminole_County_title?PARCEL=0720315070000O... 1 / 18/2005 Oct-02-00 10:03A •Fpc P.O1 Permit * Residential Swimming Pool, Spa and, Hot Tub Safety Act Notice of Requirements I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at I PkamPlintMmtA00reu) , and hereby affirm that one of the following methods will be used to meet the., requirements of Chapter 515, Florida Statutes. please initial the method(s) to be used for your pool) The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of Florida Statute 515.29; The pool will be equipped with an approved safety pool cover -that complies with ASTM F1346-91 (Standard Performance Specifications for Safety covers for Swimming Pools, Spas and Hot Tubs); All doors and windows providing direct access from the home to the pool will be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at 10 feet; All doors providing direct access from the home to the pool will be equipped with self -closing, self -latching devices with release mechanisms placed no lower than 54" above the floor or deck; l understand that not.having one of the above installed at the time of final inspection, or when the pool is completed for contract purposes, will constitute a violation of Chapter 515, F.S. and will be considered as committing a misdemeanor of the second degree, punishable by fines up to $500 and/or up to 60 days in jail as established in Chapter 775, F.S. V9OJYM ONTRACTOR'S SIGNATURE & DATE auras X. 3ura CONTRACTOR'S NAME (PLEASE PRINT) QJ t& 199 OWNER'S SIGNATURE & DATE OWNER'S NAME (PLEASE PRINT) 11amasanUso aerarnraatl®iU lU11 ee... r2 NO'I'1TCC OF COMMENCEMENT Slate: FLORIDA County: — Fst.,Aj OL-v TILE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Slawres, the following information is provided in this Notice of Commencement. PIARYAN or OFCIRCUIT COURT SEgINBK 095 CLER S to 20050i 8275 RKORDED emend g ewW4 Rill RECORDING FEES 1&W RECORDED BY L McKinley CERTIFIED COPY MAPYANNE MORSE CLFR2DE CUI,T COURT SEMINNTY, FLORIDA my CL RK h tB 0 2 Sh 1 Description of properly: (le bgal c%.scri y/iun o ru per/ 1 WT 3 3 Saq l and st'cc/ ' ac/dress i m r7il h(c) a rR-u Sly -t-t-> tJ w cT 1 N6 [CA 2• General description of Improvements: 3. Owner Information: A• Name and Address: 5 B. Inlerest- in property: — idLt . F46,-- S y" C. Name and address of fee simple titieholdcr (if other than owner): 4 Contractor: (name & address): T.\,A C., S 1 Z3 (,b paL c 1 5. Surely:S 32j A. Name and address: N/A B. Amount of bond: N/A 6• Lender: (nine and address) 7. Persons within fire State of Florida designated by Owner upon whorn notices or other documents may beservedasprovidedbySection713.13 (1)(a)7, Florida S(alures: (tonic and adih-es.$) N/A 8 In addition to himself, Owner designates (lie following `person(s) to receive a colry of the Lienor's Notice as proved in Section 713.13 (1)(b), Florida Statues: (name and address) ABOVE NAMES CONTRACTOR 9. Expiration dale of Notice of Commencement (the expiration (fate is I year for lire dn(e of recording unless adifferentdaleisspecified) Signatures of OwnerCI)rivcrs License 11: J 1 V jj rOwner's Name: SU .4 L-L- Q Lk l e:.. . Owner's Address: t Q oq u n All information must be printed legibly to comply will 'recording requirements. STATE OF FLORIDA COUNTY OF ( The foregoing instrument was acknowledged before me (his J''O by ` Vr ho is personally known to nre who has produced as idcrrlificalion.arld who did (did Trot) 1a a an oath. Signature of person inking acknowledgement) Carmen VaAone (Name of officer (akin acknowledgement - 1MyCommissionDD289519b' (; typed or IAmpC(i) Expires February 10, 2008 (Tile or rink) 1123 Seminola Boulevard o Cen gaflorida, Inc.Casselberry, Florida 32707Fo* Main Office: (407) 696-2300 FLORIDA POOLS CONSTRUCTION AGREEMENT (Part 1 of 4) FLORIDA POOLS OF CENTRAL FLORIDA, INC., "FLORIDA POOLS," State certified contractor, CPC048214, a Florida corporation whose. Corporate Offices are located at 1123 Seminola Blvd., Casselberry, FL 32707, hereby agrees to construct for and sell to si i d t/a _ l i ("Bu er") wh 'd . / I f b is 1Ij f4_6t,KC Home Phone y , ose rest ence s or p ace o usmess City J444-ffir , Florida (Zip) .3d 7 %j Office Phone ; the swimming pool and related equipment described below (herein collectively called the "work") to be installed at City Zip Legal o for the cash price of $ ) ' 72 is and Buyer hereby agrees to purchase the work for said cash price to be paid as follows: Down Paymeentt(($`/ ); Balance 40% ($ 0 " ) at excavation; 40% 0 Of-`— ) at gunite; at decks, prior to final top finish surface; and 2% ($ `5 `S 3 ) at startup of pool/spa equipment; prior to utilization - ' Florida Pools shall cant' out the work on the terms and conditions set forth on the reverse side hereof. If Buyer has not allowed construction to commence within sixty (60) days from date of this agreement, Florida Pools reserves the right to renegotiate the contract price. BUYER' S RIGHT TO CANCEL You may cancel this Agreement by providing written notice to Florida Pools, 1123 Seminola Blvd., Casselberry, FL 32707, in person, by telegraph, or by mail. This notice must indicate that you do not want the goods or services and must be sent by certified mail postmarked before midnight of the third (311) business day after signing this Agreement. If you cancel this Agreement, the Seller may not keep all or part of any cash downpayment. Any property traded in, any payments made by you under the Agreement and any negotiable instrument executed by you will be returned within ten (10) business days following receipt by the Seller of your cancellation notice, and any security interest arising out of the transaction will be cancelled. If you cancel, you must make available to the Seller at your residence, in substantially as good condition as when received, any goods delivered to you under this contract; or you may, if you wish, comply with the instructions of the Seller regarding the return shipment of the goods at the Seller's expense and risk. If you do make the goods available to the Seller and the Seller does not pick them up within twenty (20) days of the date of your notice of cancellation, you may return or dispose of the goods without any further obligation. If you fail to make the goods available to the Seller, or if you agree to return the goods to the Seller and fail to do so, then you remain liable for performance of all obligations under this Agreement. Date) I HEREBY CANCEL THIS TRANSACTION. Date) ARBITRATION Buyer' s Signature) Florida Pools and Buyer hereby elect binding arbitration as their exclusive method of settling all controversies and claims existing between them relating to this Agreement without regard to whether such claims or controversies arise under contract, tort, statute, regulation, ordinance, or other law. Arbitration proceedings shall be conducted in accordance with the Rules for Swimming Pool Arbitration adopted by the Bludsworth Central Florida Chapter of the National Spa and Pool Institute (NSPI) Arbitration Committee and said Rules are hereby incorporated by reference into the terms. of this Agreement. Additional information may be obtained by writing the chairman of the Bludsworth Central Florida Chapter at the address referenced in the RULES FOR SWIMMING POOLARBITRATION. Arbitration proceedings under this Agreement shall be commenced by either party by sending a written request for arbitration to the Chairman of the Central Florida Chapter of NSPI Arbitration Committee, together with any filing fees required. Requests for arbitration shall be submitted on "Request for Arbitration" forms that can be obtained from the local NSPI and must sefforth the issues in dispute, and or the amount claimed as damaged, and the relief sought. Notwithstanding the foregoing, Buyer and Florida Pools agree that Florida Pools retains the right to file a claim of lien against the property and to protect this lien until ultimate resolution of the dispute. Buyer acknowledges that he has read and received a complete, legible copy of this Construction Agreement (Part 1), including the items and conditions contained on the reverse side hereof, and a complete, legible copy of each other document which Florida Pools has required or requested Buyer to sign. Buyer acknowledges receipt of the Swimming Pool Specifications and the Exclusive Service Agreement (designated as Parts 2 and 4 of this Construction Agreement). Buyer shall receive a copy of the Plans (designated as Part 3 of the Construction Agreement) as soon as they are completed. Dated this (0 day of -11, , 20015, Buyer' s Signature Buyer' s Signature JI 1 di - 0 a Representative FLORIDA POOLS This Agreement of the Seller. Accepted this date By Title is not valid until accepted by an officer Revision Date: 6120/00 PLAT OF BOUNDARY SURVEY for ALICE & HAROLD SUNDVALL Legal Description LOT 33, SANORA SOUTH UNIT ONE, according to the Plat thereof and 76, of the Public Records of Seminole County, Florida. as recorded in Plat Book 19, Pages 75 E.--------------- N U n FND IRON do CAP-(NO #) ' N ' : 8 9 °5 9 12 ' E 6 2.0 0 F"D 1' IRON f'IPF (NO 34 zm z O 30D rni O 0O O C,z OmS31 Ell 32 4 CONC. UK. WALL o mSETIRON ---_------' - CAP (#3382) v N 8 9 °5 9' 12" E 6 2. 0 0' CAP I(# 3382) Qx NJ' r r Or OZf+l C-0RN-WALL--_--rm7UnX. - - -- - - - SCALE: 1 "= 20' SURVEY NOTES: 1) The street address of the above -described property is 119 RABUN COURT. 2) The -above -described property lies in a Flood Zone X. O W F- O z u7 Q W JQ ULn SURVEYOR'S CERTIFICATE This is to certify that I have made a Survey of the above described property and that the plat hereon delineatedisanaccuraterepresentationofthesame. I further certify that this Survey meets the Minimum Technical Standards set forth by the Florida Board of Land Surveyors pursuant to Section 427.027 of the Florida Statutes. CERTIFIED CORRECT TO- R. BLAIR KITNER - P.L.S. NO. 3382 Post Office Box 823, Sanford, F1. 32772-0823 4W) 322-2000 PROJECT NO: 04 -99(o SURVEY DATE: 20 DECEMW Z004 I PLAT OF BOUNDARY SURVEY for ALICE & HAROLD SUNDVALL tion LOT 33, SANORA SOUTH UNIT ONE, according to therPlat thereof and 76, of the Public Records of Seminole County, Florida. FND IRON & CAP-(NO #) 34 as recorded in Plat Book 19, Pages 75 FND 1" IRON PIPE (NO z 0 0 O O 39' 32 0 0 0 0 b U IIL. ESM•T j V//1-'C0KC• UV WALL SET IRO & -Q m---"------ CAP (#3382)zr N 89-59'12" E 62.00 CAP - SETI( y3382) 0 N D Ul r r Or Z Orri SCALE: 1 "= 20' SURVEY NOTES: 1) The street address of the above -described property is 119 RABUN COURT. 2) The -above -described property lies in a Flood Zone X. O W H O Z Ln a w J Q U U') A SURVEYOR'S CERTIFICATE This is to certify that I have made a Survey of the above described property and that the plat hereon delineatedisanaccuraterepresentationofthesame. I further certify that this Survey meets the Minimum Technical Standards set forth by the Florida Board of Land Surveyors pursuant to Section 427.027 of the Florida Statutes. CERTIFIED CORRECT TO: R. BLAIR KITNER - P.L.S. NO. 3382 Post Office Box 823, Sanford, Fl. 32772-0823 4W) 322-20M PROJECT NO: 04.99(o SURVEY DATE: 20 DECEMBEC 2004 i PLAT OF BOUNDARY SURVEY OFQfor ALICE 81 HAROLD SUNDVALL Legal Description LOT 33, SANORA SOUTH UNIT ONE, according to the Plat thereof as recorded in Plat Book 19, Pages 75and76, of the Public Records of Seminole County, Florida. Q- JMBW4 - --C—T—.- — - — - FND IRON do CAP—(NO #), 34 R7 Z mz O zm O 0o O r'• z Om a SET IRON & o cof` I CAP (#3382) 0 I V 0 A D r z rn 89*59112 E 62.00 coed-wrAtL--:- SCALE: 1 "= 20' FND 1" IRON PIPE (NO z N J O O 32 W/6 CONC. WW WALL SET IRON & CAP (y3382) N Ln O O SURVEY NOTES: 1) The street address of the above -described property is 119 RABUN COURT. ' 2) The -above -described property lies in a Flood Zone X. O 111 H O z cn cc 1Q U to a SURVEYOR'S CERTIFICATE This is to certify that I have made a Survey of the above described property and that the plat hereon delineatedisanaccuraterepresentationofthesame. I further certify that this Survey meets the Minimum Technical Standards set forth by the Florida Board of Land Surveyors pursuant to Section 427.027 of the Florida Statutes. r CERTIFIED CORRECT TO: vv..vV •11.V 11•l.. R. BLAIR KITNER - P.L.S. NO. 3382 Post Office Box 823, Sanford, F1. 32772-0823 407) 322-2000 PROJECT NO: 04-99(o SURVEY DATE: 20 DECEMW 2004 79t4DistanceSPECIFICATIONS Directions_ . _.._................ ......_.......-_.........................._.........__.............. 1, jy , 1. Start out going WEST on SEMINOLA BLVD toward N WINTER PARK OR. 1.4 mi POOI Dimensions: Size 9 x ;} ;Depth pp6.0 Special Depth J oy 2. Turn SLIGHT RIGHT onto uS-17 92 N/US 92 N/US-17 N. 6 0 miles Water Surface Area 7 rime etsq. ft.; Perimeterter FilterT fe O 3. Turn RIGHT onto E LAKE MARY BLVD. 1.3 miles YPe ; Size PUMP TYPE, e size a. Turn LEFT onto cR-427. 0.1 miles Additional Pumps e T o 2 miles Return Inlets - No, .i Skimmer No. O 5. CR 427 becomes S SANFORD AVE/CR-425. . . Sanitizing Syste LVA 1. Z 0. 1 miles 6. Turn RIGHT onto STENSTROM BLVD. Heater -Type Size GAS LINE AND,OR TANK PAWN AND HOOK-UP IS THE O7. Turn RIGHT onto RAN Cr. <0.1 miles RESPONSIBILITY THE BUYER. _ /^ 8. End at 119 Rabun Ct, Sanford, FL32773-5820 US Cleaning System c7 0 C V Step/ Bench Pkg, Other Plumbing 011 HnKAFOV1/NFR TO RFMOVE STENSTROM BLVD Water Feature 31. Water Line Tile Color k-k Step Edge Tile i n J Color 32. Raised Beam `iN 33. CopingQ4-1- Q vela LF `- ; Color '- 34. Grab Rails & Recessed Steps ;Hand -Rail Swimout = x - ; Bench x ; Step -outs) # Additional Bench, LF - 35. Underwater Light IV 36. Therapy Spa x ; Sq. Ft. _i_ Raised-6 Jet No. Spa Light __in-J Special Notes - GI '- as. Bock - 37. Deck Color_b Additional Deck Work sq. ft. Deck Pilasters L.F. Height Deck Steps _ L.F. Deck- O-Drain ! L.F. Footings L.F. 38. Retaining Wall 39. FLORIDA POOLS to remove on day of excavation: Stumps - No. 0 Concrete/Asphalt Sq. Ft. J Uprooted Vegetation and Other Debris 40. Total No. of Loads to Rerpove.. D 41. Double Dirthandling Pump from Street E' Buyer to have following located, rerouted or remov d required: Septic Tank ( ; Gas Line Water Line Telephone Line ; Power Lin r ers Sewer Line 42. Access: Right ()<Left ( ) Rear (. ) Fence Replacement ( )Yes ) No Permission over driveway Permission over next lot Sidewalk Replacement ( XYes ( ) No 43. Additional Grading Cu. Yd 0 Water Source 44. Interior Pool Finish L7 45. Auto Controls 46. Additional Electrical 47. Screen Enclosure _ `Z- Color Roof Doors a _ Gutters 48. Child Safety Fence -P_j Dth r Sp al Con uction Features a d E ulpment; Notes 4" NOM. "FIBER MESH" CONCRETE DECK W/ SLIP RESISTANT TOPPING ON COMPACTED GROUND LE1 1GTrfi W/ ALL ORGANIC MATERIAL REMOVED (OPTIONAL) WATER LINE LIGHT STEPS 1 # 3 BAR CONT. W/ 5 " + 4 ' 0 " MIN. I 5 "+ WALL- W/ 8 " x 8 " BOND 8 " 6 " TILE 8' MAX. BEAM USE 2 # 3 BARS CONT. MIN MAXIMUM RISER = 12" MINIMUMTREAD = 10" (240 SQ.IN.) 6! T SUCTION INLETS SET INTO CENTER OF 18" MIN. TO STEEL GRID AT POOL DEEP POINT TOP OF LENS POOE. LONQMMML SECTION DISTANCE LESS THAN 1 ON 1 a 1 EXISTING STRUCTURE MARBLE REFER TO ATTACHED DRAWING PLASTER FOR DATA REGARDING DUAL FINISH s-THIcxwAu _ SUCTION INLET SYSTEM AND waeLc usrrk E 3 BARS AT I I.C. VACUUM RELIEF SYSTEM Fl NID" EACH WAY lbyezL.TCc Fozm THE CONTRACTOR MUST PUCE ALL STEEL IN THE POOL WALL AT NO MORE THAN SINCHESONCENTERINOOTHDIRECTIONSINTHISCRRICALAREA. ALSO THE POOL SHELL WALL SHALL U CONSTRUCTED AT i INCH THKXNEZIL THIS STEEL MAT AND SHELL WALL SHALL BE EXPENDED ALONG THE CRITICAL AREA AND TO A POINT WWCH IS GREATER THAN THE MWIAtJM REQUIRED DISTANCE AS OFTERM@IEO fY THE i ON 11METHOD. TYPICAL WALL AND FLOOR WITHIN ANGLE OF REPOSE s- # 8 AWG COPPER WIRE s TIMECLOCK n I I- JUNCTION BOX I i (BY OTHERS) I I11 III OUTER EDGE OF I I DECK TO CONFORM I WITH LOCAL CODE II TO TRANSFORMER BY OTHERS) i = = --Jmmm. U.L. APPROVED 120 VAC430OW POOL LIGHT W/ GFI OR 12VK300V POOL LIGHT W/ LOW WATE'; CUT OFF IN U.L. APPROVED GREY PLASTIC FORMING SHELL W/ NO.8 BOND PER N.E.0 STEE1 TEX FORM (OPTIONAL) 3 BARS 12" O.C. EA WAY P001- STRCTAL DETAILS ALL STRUCTURAL, FILTRATION, AND ELECTRICAL CETAILS OUTLINED IN THESE CRAVINGS ALSO RELATE TO SPA CONSTRUCTION. TO I SERVICE PANEL I JCT. BOX SPST 4' MIN +TOGGLE 4 SWITCH 8 " MIN W.P. DISC J R 12 V. TRANS PUMP 1 POOL DECK W/ 12 V. SYSTEM I 1. MAIN DRAIN LINE , j2SI4MMERLINEi 3. WASTE LINE 4. RETURN LINE 5. PRESSURE CLEANING C LINE ( OPTIONAL) J 5 4 2 12 V/300 WWI LOW 3 # 12 ALL ELECTRICALWATERCUT-OFF IN Y2 " COND FORMSHALLCONOR120VAC. W/GFI WART. ON N. E.C. PERN.E.C. ELECIRKAL DIAGRAM FILTER SYSTEM MIN. 2" COVER OVER ALL BARS LLIir 6"TILE5 1 # 3 BAR CONT. WI S WALL- W/ 8' x 8' BOND BEAM USE 2 S 3 DECK BARS CONT. BRICK OVERPOUR ( 1 ROW) ALTERNATE BEAM FINISH DETAIL 3 A F B A. HAIR 8 LINT STRAINER 8. REGRCULATOR PUMP C. FiLTER D. IN4JNE CHLORINATOR C? TIONAL) E. HEATER (OPTIONAL) VALVE NOT VALID WITHOUT RAISED SEAL Y 2 5 200A DATE ENERAL NOTE 1. FOR POOL PLAN, SIZE, DECK SPECIAL DETAILS SEE CONTRACTOR'S POOL PLAN. 2. POOL WALLS SHALL BE 5 " THICK AND FLOORS SHALL BE 6 " THICK AND SHALL BE PNEUMATICALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 3,000 PSI IN 28 DAYS. CONCRETE DECK SHALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318. 3. ALL POOL CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING CODE 2001 AND ANSI NATIONAL STANDARD-5 FOR RESIDENTIAL INGROUND SWIMMING POOLS AND ANSVNSPI NATIONAL STANDARD-3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS. 4. ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. 5. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40, REINFORCING SHALL BE # 3 BARS AT 12 " O.C. EACH WAY WI 15" LAP JOINT IN WALLS AND FLOORS UP TO 6'. OVER 6' USE # 3 BARS AT 6" ON CENTER EACH WAY IN THE AREA OVER 6'. 6. ALL METALLIC POOL FITTINGS WITHIN 5 FEET OF THE INSIDE WALL AND DECK REINFORCING STEEL TO BE BONDED TO THE POOL REINFORCING STEEL WITH # 8 AWG COPPER WIRE. #8 AWG COPPER WIRE TO BE RUN INTERNALLY AND EXTERNALLY WITH THE NEC APPROVED PVC LIGHT CONDUIT FROM THE LIGHT NICHE TO THE JUNCTION BOX. COMPLETION OF POOL GROUNDING TO PANEL GROUND BY ELECTRICIAN. 7. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR CLEAN SAND, WHICH SHALL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY. ANY UNSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN ITS ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. 8. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS IF REQUIRED. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 9. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EAESEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. 10. CONTRACTOR SHALL DETERMINE LOCATION OF ALL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIONS AND ORDINANCES. 11. WARNING! TO EMPTY THE POOL FOR ANY REASON, THE HYDROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. N H. SVETDSON, P.E FL( P. NO. 1 3 17 FSIDE DRIVE WI R PARK, FLORIDA 32792 PHONE ( 407)657-4133 03• R* or Ceninl AdRds, Inc. 1123 SEMINOLA BLVD CASSELBERRY, FL 32707 RESIDENTIAL SWIMMING POOL MASTER SPECIFICATION I DRAWING i FOR CITY OF SANFORD NOT TO SCALE DWD BY-- GHS s VACUUM LINE OPTIONAL) Np SAFETY VACUUM FITTING 1xl,r f VE Ul VACUUM LINE OPTIONAL) M SAFETY VACUUM FITTING \ SKIMMER iX•0 FEATURE MAx 1r oPT>owu.l yS • A mnVORTEX COVER r o VE u I ro ro SUCTION INLETS MAIN DRAINS) SWIIIMMNG POOL SECTION VACUUM LIFE 9LIEam 'B' OPTIONAL) WU SAFETY VACUUM FITTING \ sK/r+MER 1X' I ML, LJZ I — MAX1X' AN/ r VE tt r o -1 SUCTION INLET MAIN DRAIN) SKI a` MV(,r AMTI40R7EX 4 3' r r0 SVVW NING POOL SECTION - SWIMMING POOL SECTION BLIEBdATE'C" RESIDENTIAL SWIMMING POOL, SPA AND WADING POOLS DUAL SUCTION INLET SYSTEM 8, VACUUM RELIEF SYSTEMS IN ACCORDANCE WITH SECTION 424.2.6.6 OF FLORIDA BUILDING CODE ANMORTSX COVER SUCTION INLETS MAIN DRAINS) SPA PUMP j' VE 0 r o SUCTION INLETS MAIN DRABS) SPA SECTION Ai TFRPLATE 'A' SKIMMER ANTIVORTEX COVER SPA Lr FL VE u r 0 sucnoN INLET MAIN ORAIN) SPA SECTION ALTERNATE'E' AN APPROVED VACUUM RELEASE SYSTEM SUCH AS THS VAC- ALERT.TM SVRS SYSTEM IS AN ALTERNATIVE VACUUM RELIEF DEVICE, INSTEAD OF EITHER OF THE TWO SYSTEMS SHOWN. ATTACH PLACKARD WHICH STATESTHATVENTISASVNMMINGPOOLSAFETYDEVICEANDSHOULDNOTBETAMPEREDWITH. ALTERNATE SUCTION INLET SYSTEM MAY INCLUDE 1 ON THE BOTTOM AND ONE ON THE VERTICAL WALL,OR ONE EACH ON TWO (Z) SEPARATE VERTICAL WALLS VENT TO ATMOSPHERE SO VENT WILL NOT BE BLOCKED I3Y DEBRIS, INSECT INFESTATION.OR MICROBIOLOGICAL CONTAMINATION COVER MUST COMPLY WITH ANSUASME A112.19.5 M) r (r MINIMUM S ALTERNATE 2' T re ra SUCTION SUCTION Iwo INLET INLET MAXIMUM DISTANCE r0 1X- 0 ALL VENT TO VENT TEE PIPING . 1X- 0 CONNECN 1' TIO VENT COVER MAY BE GUTTER DRAIN SUCH AS HAYWARD MODEL SP-1019 2- 9O` ELBOWS i A' 0 VENT PIPE SUGGESTED DETAIL 12" MIN. 1) VERTICAL TOLERANCE IS * r I) WATER LEVEL MARK TO PUMP VE II CAP ti TO PUMP GREATER THAN 2' 0 T" CONNECTION VE 11 TO PUMP UP TO 2' 0 PASS THRU CONNECTION PLAN VIEW VEII CONNECTIONS VENTED COVER SUCH AS SKIMMER COVER W/ COLLAR VENT AND EXTENSION SET CAP FLUSH/W/ DECK ii FNp=— K TO PUMPPVC SLEEVE NDED FROM COVER COLLAR VENT IN DECK CAP t 6" MIN THREADED EXTENSION / COUPLE c r Yir/c i/.fir w'r, DECK TO PUMP OFF DECK SECTION VIEW— INSTALLATION OPTIONS ATMOSPHERIC VENT PIPE LENGTH gms r o MINIMUM -IV MAXIMUM - 3Lr ALL SUCTION TO PUMP PIPING - r 0 d_ _ THE MAXIMUM VACUUM WITH ONE MAXIMUM SUCTION PIPE VELCcTTY SUMP PLUGGED AND TO RELEASEsuc(6) FPS OR sa G" = LSON IN=ST A BODY ENTRAPMENT ON THE OTHER SUMP HALLNOT EXCEEDED 4.5 HERIC INCHES OF MERCURY IN 3 SECONDS n . 2!;04 R H. HEP4ROSON, P.E PE,NO1 f 17 SI NE WINTER PARK, FL 37M PHONE: (407) 6b7-4133 FAX: (407) a57-4133 DECK- WATER LEVEL 4'18%" > I _ Il w 1-3' MIN. -.I a a TYPICAL POOL AND SPA INSTALLATION SUCTION FLOW FOR RESIDENTIAL POOL = 8 FPS SUCTION FLOW FOR RESIDENTIAL SPA - 6 FPS CONTRACTOR MAY CHA SUCTION PIPE SIZE TO MEET THESE REQUIREMENTS ICTION LOSS M PIPE ELBOWSF45' W. ELBOW ELBOW 2' 4' 2'fi' 6' 2 Yi 3' 8' 3' 4' 8' 4' 5' 12' 5' 6' 14' PIPE LENGTH TO VE II = "L" - ELBOW FRICTION LOSS EXAMPLE: THE MAXIMUM PHYSICAL PIPE LENGTH FROM MAIN DRAIN TO VEII IF USE 2" 0 PIPE W/ 2-90' ELBOWS AT 6 FPS IS 54' - 12, = 42' VACUUM SUCTION ELIMINATOR — VE II AVE II IS REQUIRED FOR EACH PUMP PLUMBED TO AMAIN DRAIN at viral Florida, Inc. 1123 SEMINOLA BLVD CASSELBERRY, FL 32707 MASTER DRAWING NOT TO SCALE DWD BY- GHS