Loading...
HomeMy WebLinkAbout147 Walnut Crest Run (3)PP,M (7 N (0-7 C_t.N1-t-cxRX>t._, Permit # S Job Address: Description of Work: Historic District: CITY OF SANFORD PERMIT APPLICATION 7-1 /U le 22 Zoning: Value of Work: Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout &Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Commercial 77A Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type:- p # of Stories: #of Dwelling Units: Flood Zone: (FEMA form required for other than X) 1 Parcel #: 22- 1 — l/LJl> 1 07O (Attach Proof of Ownership Legal Description) Owners Name & Address: -A -C- N.r , it 16 _ Contractor Name Phone & Fas: 7 D 7- Bonding Company: _ Address: Mortgage Lender: Address: Architect/Engineer: YAddress; P. o. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that ork o installation has commenced prior to theissuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS,'FURNACES, BOILERS, HEATERS; TANKS, andAIRCONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatingconstructionandzoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYINGTWICEFORIMPROVEMENTSTOYOURPROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records ofthiscounty, and there may be add' 'onal permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of pe t i fr r n that I will notify the owner of the property of the require s of orida ten La 7 3. Signatu of wner/A ent Date Signature of Contractor/Agent ateI _1_)a V 'a Print q"' `.gent'a N e Print Contractor/Agent's NamelJ 'wg` Notary -State Date N PM d' ANO SignatureofNotary -State of Florida ,au Date Signature of Nota State of Florida \` \, ••......• • Er1c Mslla°n•.k\56 10N YA•. MY Corr M411ion DD317772 met 25,? 9; • Owner/ Agent is _Personally Knowi44t1e^saY . Z008 Contractor/Agent is J Personally Known to Me or +* • • ProducedID _ Produced ID Q APPLICATION APPROVED BY: Bldg F Zoning: Initial & Date) Special Conditions: Initial & Date) Utilities: FD: Initial & Date) (Initial & C Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 PARCEL DETAIL t <1 Back r W f 5cmintAr Counly r„ s rVPrr1V4r0rPPra15f,' rvicri; 11111 9. Viral S., anford Ml. 127-1 GENERAL 2005 WORKING VALUE SUMMARY S3-SANFORD- Value Method: Market Parcel Id: 0000-130-502- Tax District: WATERFRONT0001070 Number of Buildings: 0 REDVDST Depreciated Bldg Value: $0 Owner: CENTEX Exemptions: HOMES Depreciated EXFT Value: $0 Land Value (Market): $26,000 Address: 385 DOUGLAS AVE STE 2000 Land Value Ag: $0 City,State,ZipCode: ALTAMONTE SPRINGS FL 32714 Just/Market Value: $26,000 Property Address: 147 WALNUT CREST RUN SANFORD 32771 Assessed Value (SOH): $26,000 Subdivision Name: PRESERVE AT LAKE MONROE Exempt Value: $0 Dor: 00-VACANT RESIDENTIAL Taxable Value: $26,000 2004 VALUE SUMMARY SALES 2004 Tax Bill Amount: $533 Deed Date Book Page Amount Vaclimp 2004 Taxable Value: $26,000 Find Comparable Sales within this Subdivision DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS LAND LEGAL DESCRIPTION PLA'i Land Assess Method Frontage Depth Land Units Unit Price Land Value LOT 107 PRESERVE AT LAKE MONROE PB 62 LOT 0 0 1.000 26,000.00 $26,000 PGS 12 - 15 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ears property tax will be based on Just/Market value. http://www. scpafl.org/pls/web/re_web. seminole_county_title?PARCEL=2219305020000... 12/ 16/2004 ACTION ALUMINUM PRODUCTS, INC 2698 South Orange Blossom Trail Orlando, Florida 32805 POWER OF ATTORNEY I hereby name and appoint P!ZA)47Z. Johns to be my lawful attorney, in fact to act for me and apply toAhe Building Department fora PooL screen eve o' scee permit to be performed at a location described as: oT 107 P26--C-7zv,r- ( L 4 C- /4,9A)12E And to sign my name and do all things necessary to this appointment. 9,Q-04 David Allan J has CGC 053605 SUBSCRIBED BEFORE ME THIS DAY OF 17,&q-4 200 s- Notary as to Contractor My Commission METRO ORLANDO (407) 648-9948 • Fax (407) 648-9949 9 BREVARD (407) 632-0264 9 VOLUSIA (904) 252-7835 P 2EPvRE') V y A0V0L,'> ri NOTICE OF COMMENCEMENT pc c-fhvvo c 3z8o State of Florida F?,rh-o J 1 U -7 County of Seminole Permit No. Tax Folio No. (PID) The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. CRIPTION OF r ro(7_ a I description of the property and street address) GENERAL DESCRIPTION OF IMPROVEMENT _ , Sl^ rerA eA.0 A-S uke IED COPY OWNER INFORMATION^' J Name and address I.M1 Interest in property (Fee Simple,Tartriersirip, etc.) Owner/builder. U MAR, r0 2na1 NAME AND ADDRESS OF FEE SIMPLE TITLE HOLDER•(IF OTHER THAN OWNER) CONTRkkCTOIR1 Name andlWddss SURETY (Bonding Company) Name and address U h tfl1 { 11 I t11 III iN11 I II U I I I11 DPI328 MARYANNE MORSE, CLERK OF CIRCUIT COURT SEMINOLE COUNTY Amount of Bond 13 x CVVJVYIVC7 RECORDED 03/10/2005 04t01:05 PM DOCUME1tFCaRTAMR10 B100 LENDER 38S D IMP Xkholden Name and address AI>nno lie tisrin PL 3.'t7A Persons within the State of Florida designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: Name and address JA In addition to himself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Expiration. Date of Notice of Commencement The expiration date is 1 year from date of recording unless ent JaM is specified.) S ignaf6el Owne t ` Sworn to and subscribed before me this Day of 7 1 21Eric "1 W *Xommission Expires: Notary Public ; "'r cGQIMI o s a Expiroa July 09, 2M The forego'= e,7-/4- strument was acknowledged before me this _ day of ems. ,F V by name of person acknowledged), who is personally known to me or who has produced (type of identification) as identification and who did / did not take an oath> rn c) &3 (0 PLAT OF SURVEY DESCRIPTION: (AS FURNISHED) LOT 107, PRESERVE AT LAKE MONROE AS RECORDED IN PLAT BOOK 62, PAGES 12-15 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. 1" = 30' GRAPHIC SCALE 0 15 30 FOR THE BENEFIT OF AND EXCLUSIVE USE OF: COMMERCE TITLE COMPANY COMMERCE TITLE INSURANCE COMPANY CTX MORTGAGE COMPANY, LLC CSX_ RAILROAD RIGHT OF WAY UNPLATTED _ PER THIS PLAT N0 N54'23'11 "W 50.00' 0 BERM & LOT 07 ro I Z q 7.250 SO. FT. t hI ImII IIC LOT 108 U z o I m 1 LOT 106 5.0' I 40.0' 3 c C ltl Q N o FORMBOARD FOUNDATION TOP OF FORMS o O O O _ o m n ELEVATION-17.80 n LidLri r y V To V / 6.3' ° 20.7' 15.0' 5.01 r. I 0.7' I F-------- T ui m I YFANSREVIEVV' UTILITY ----- TC1 • Y OF SANfpDEASEMENT S54'23'11' E u 50, 00' o rTII u I1I PC— _ 478.6 718.04' 4 55 3' " P Ij NOTE: 1. PROPERTY CORNERS SHOWN HEREON WERE SET/FOUND ON 11-03-04. UNLESS OTHERWISE SHOWN. 2. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. 3. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 4. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 5. ALL INTERIOR DIMENSIONS WERE VERIFIED IN THE FIELD AND SHOWN UPON THIS DRAWING, 5. THIS IS AN AS -BUILT SURVEY DELINEATING CONSTRUCTED IMPROVEMENTS ONLY AND COMPLIES WITH SECTION 61G17-6.005 F THE FLORIDA ADMINISTRATIVE CODE FOR AN 4S-BUILT SURVEY, I HAVE EXAMINED THE F.I.R.M. COMMUNITY PANEL N0. 120294 0035 E DATED 4-17-95 AND FOUND THE SUBJECT PROPERTY LIES IN ZONE X. AREA OUTSIDE 100 YEAR FLOOD PLAIN THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT TIE LOCAL F.E.M.A. AGENT FOR VERIFICATION. ELEVATIONS SHOWN HEREON ARE BASED ON SEMINOLE COUNTY VERTICAL CONTROL AS FURNISHED, BEARINGS SHOWN HEREON ARE BASED ON NORTHEASTERLY LINE OF LOT 107 BEING S54'23'11"E PER PLAT. FIELD DATE:) 11-03-04 REVISED: 1" = 30 FEET FORMBOARD 11-15-04 CKB SCALE: MODEL CHANGE 10/27/04 KLE APPROVED BY: SJ PLOT PLAN 7/28/04 SOO PRELIMINARY (1)10-22-03 NL REVISE STREET NAME 3-12-OS JML JOB NO. ASM38315 ADDED PLAT BOOK AND PAGE 3-10-03 CKB DRAWN BY LOT PLAN 10-14-02 JML 42 11 E WALNUT CREST RUN RIGHT of WAY 50' RIGHT OF WAY LEGEND BUILDING SETBACK LINE CENTERLINE RIGHT OF WAY LINE 1 T 4 EXISTING ELEVATION CONCRETE LB LICENSED BUSINESS LS LICENSED SURVEYOR PRM PERMANENT REFERENCE MONUMENT PCP PERMANENT CONTROL POINT P) PER PLAT M) MEASURED FND FOUND C/W CONCRETE WALK S/W SIDEWALK CP CONCRETE PAD CS CONCRETE SLAB C CHORD LENGTH ELEV ELEVATION PK PARKER KALON R RADIUS POC POINT OF CURVE AMERICAN SURVEYING & MAPPING CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 1030 N. ORLANDO AVENUE, SUITE 8 WINTER PARK, FLORIDA 32789- (407) 426-7979 FND WITNESS POINTE O1/2" IRON ROD AND CAPLB #6393 (11/03/04) QFND NAIL AND DISCLB #68 (11/03/04) FND 1/2'IRON ROD AND CAP LB #6393 (11/03/04) CNA CORNER NOT ACCESSIBLE a DENOTES DELTA ANGLE L DENOTES ARC LENGTH C.B. DENOTES CHORD BEARING PC DENOTES POINT OF CURVATURE PI DENOTES POINT OF INTERSECTION PRC DENOTES POINT OF REVERSE CURVATURE PT DENOTES POINT OF TANGENCY TYP. TYPICAL A/C AIR CONDITIONER COW CONCRETE BLOCK WALL RP RADIUS POINT OHU OVERHEAD UTILITY LINE ID IDENTIFICATION POL POINT ON LINE PCC POINT OF COMPOUND CURVE REV REVISED SUBJECT TO THE SURVEYOR'S NOTES CONTAINED HEREON MEETS THE APPLICABLE MINIMUM TECHMI;AL STANOAROS" SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPFRSiN CHAPTER 61G17-6, FLORIDA ADMINiSTRATIVE CODE PURSUANT TO CHAPTER 472.027, FLORIDA STAIUIES. 71,eye FOR THE FIRM IMES JAY JILES PSM #4997 DATE Nwwl CENTEX POOLS & SPAS r PLANS REVIEWED CITY OF SANFORD m #0:5 4' OFFICE COPY 8'-0' - n 0. I 0 co I mmpmq MPAAV MMPMMREM ml:mllmllrl PAAVEN: No 0 u U 36' -0' T m i L I I FmRim m IYAi104M fflml mu."llmlml T-6• T-0' 7'-0• 71-0• T-60 _ 8'-09 - 8'-0• - JOB No, PBMON147 January 01, 2005 LAWRENCE E. BENNETT, P.E. P.O. BOX 214368 SOUTH DAYTONA, FL 32121 386-767-4774 TO -ALL BUILDING DEPARTMENTS Re: Master File Engineering 2004 "ALUMINUM STRUCTURES DESIGN MANUAL" i Dear Building Official/Plans Examiner, This is to certify that the following contractor/comaanyisherebyauthorizedtousemy "ALUMINUM STRUCTURESDESIGNMANUAL" for the year 2005. This authorization also applies to contractor Master FileDrawings, "ONE JOB ONLY" drawings, or any "SITE SPECIFIC" drawings that I may furnish for the contractor. David A. Johns Action Aluminum Products, Inc. 2698 South Orange Blossom Tr. Orlando, FL 32805 Should you have a convenience. Sincerely,.:; Lawrence, Bennet questions please contact me at your E. #16644 SECTION 1 1 SCREENED ENCLOSURES Table 1.1 Allowable Spans for Primary Screen, Roof -Frame Members Aluminum Alloy 6063 T-6 i For Areas with Wind Loads up to 150 M.P.H. and Latitudes Below 30"-30'-00" North (Jacksonville, FL) Hollow Sections Tributary Load Width = Beam Spacing 3'-0" 1 4'-0" 1 5'-0" 1 6'-0" 7'-0" 1 8'-0" I 9'-0" Allowable Span'L' 1 bending b' or deflection'd' 2" x 2" x 0.044" 9'-10" b 8'-7" bi 7'-8" b 6'-11" b V-6" bl VA" b 1 5'-8" b 2" x 2" x 0.055" 10'-9" b 9'-0" b 8'4" b 7'-7" b 7'-1" b 6'-7" b 6'-3" b 2" x 3" x 0.045" 13'-0" b 11'-7" b 10'4" b 9'-5" b 8'-9" b 8'-2" b 7'-8" b 2" x 4" x 0.050" 14'-8" b 12'-8" b 1 V-4" b 10'4" b 9'-7" b 8'-11" bI 8'-5" b Self Mating Sections Tributary Load Width 'W' = Beam Spacing 3'- 0" 1 4'-0" 1 5'-0" 6'-0" Allowable Span 'L' 1 bending 'b' or deflection 'd' 2" x 4" x 0.044 x 0.100" 19'-11" b 17'-4" b 15'-0" b 14'-2" b 13'-1" b 12'-3" b 11'-6" b 2" x 5" x 0.050" x 0.100" 24'-9" b 21'-5" b 19'-2" b 17'-6" b 16'-2" b 15'-2" b 14'-3" b Z' x 6" x 0.050" x 0.120" 28'-7" b 24'-9" b 22'-2" .b 20'-3" b 18'-9" b 17'-6"' b 16'-6" b 2" x 7" It 0.055" x 0.120" 32'-3" b 27'-11" b 24'-11" b 22'-9" b 21'-1" b 17-9- b 18'-7" b 2" x 7" x 0.055" wl Insert 42'-10" b 37'-1" b 33'-2" b 30'4" b 28'-1" b 26'-3" b 24'-9" b 2" x 8" x 0.072" x 0.224" 41'-7" b 36'-1" b 32'-3" b 29'-5" b 27'-3" b 25'-6" b 24'-0" b 2" x 9" x 0.072" x 0.224" 45'-1" b 39'-1" b 34'-11" b 31'-11" b 1 29'-6" b 1 27'-8" b 26'-1" b 2" x 9" x 0.082" x 0.310" 49'-6" b 42'-11" b 38'-0" b 35'-0" b 32'-5" b 30'-4" b 28'-7" b 2" x 10" x 0.092" x 0.369" 59'-6" b 51'-7" b 46'-1" b 42'-1" b 38'-11" b 36'- b 34'-4" b Snap Sections Tributary Load Width 'W' = Beam Spacing 3'- 0" 1 4'-0" 1 5'-0" 1 6'-0" 7'-0" 1 , 8'-0" 1 9'-0" Allowable Span'L' 1 bending'b' or deflection 2" x 2" x 0.044" 11'-9" b 10'-2" b 9'-1" b 8'-4" b 7'-11" b T-2" b 6'-9" b 2" x 3" x 0.045" 15'-1" b 13'-1" b 1 V-8- b 10'-8" b 9'-10" b 9'-3" b 8'-8" b 2" x 4" x 0.045" 18'-5" b 16-11' b 14'-3" b 13'-0" b 12'-l" b 11'-3" b 17-8" b 2" x 6" x 0.062" 31'-3" b 27'-1" b 24'-2" b 22'-1" b 20'-5" b 19'-2" b 18'-0" b 2" x T" x 0.062" 34'-9" b 30'-1" b 26'-11" b 24'-7" b 22'-9" b 21'-3" b 20'-1" b Note: T 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thickness shall be less than 0.040". 2. The structures designed using this section shall be limited to a maximum combined span and upright height of 55' and a maximum upright height of 20'. Structures larger than these limits shall have site specific engineering. 3. Spans are based on a minimum of 10# / Sq. Ft. for up to a 150 M.P.H. wind load. 4. Span is measured from center of beam and upright connection to fascia or wall connection. 5. Above spans do not Include length of knee trace.? Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 6. Pudin spacing shall not exceed 6'- 8" . For beam spans greater than 40'-0" the beam at the center purlin and one purlin for each 14'-0" on each side of the center purlin shall Include lateral bracing as shown in detail (48'-0") span with pudins at 6'- 8" o.c. center purlin and (2) purlins each side of center purlin need lateral bracing. 7. Spans may be interpolated. Example: Max. 'L' for 2" x 4" x 0.050" hollow section With 'W' = 5'-0" = 1 V-4" Lawrence E. Bennett, P.E. FL # 16644 CML ENGINESR - DEVELOPMENT CONSULTANT P. O.9OX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: ( 356) 767-4T74 FAX: ( 366) 767-GM PAGE COPYRIGHT 2004 1- 56 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E. r SECTION 1 I SCREENED ENCLOSURES 0.05" H-CHANNEL OR GUSSETSI COMPOSITE 2 x 3 EAVE RAIL BEAM -SCREEN Z WJ POST TO BEAM FASTENING ROOF a a Q SEE TABLE 1.6) 2> wz x SCREEN um,®® MAY FACE IN OR OUT) REQUIRED KNEE BRACE MINIMUM SIZE AND CONNECTION (SEE TABLE 1.7) ATTACHED NO MORE THAN 6" ENGTH w ABOVE TOP OF GUTTER E BRACI CD0- O w ai HOST STRUCTURE ROOFING 2) 2" LAG SCREWS (SEE SECTION 9 FOR SCREW SIZES) 2" STRAP LOCATE AND Fe ® — — — — FASTEN PER STRAP LOCATION DETAIL PAGE 1-21 SOFFIT 2" x 2" x 0.062" ANGLE EACH SUPER OR SIDE (3) EACH #8 S.M.S. EACH EXTRUDED LEG INTO POST GUTTER BEAM CAP (SEE PAGE 1-22) MAX. DISTANCE TO OPTIONAL 3/8" LAG SCREW HOST STRUCTURE AND 3/4" FERRULE WALL 24" WITHOUT FASCIA AND SUB -FASCIA SITE SPECIFIC ENGINEERING IF KNEE BRACE LENGTH EXCEEDS TABLE 1.7 USE CANTILEVERED BEAM CONNECTION DETAILS SUPER OR EXTRUDED GUTTER RISER (OR TRANSOM) WALL AT FASCIA - DETAIL 6 SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214365. SOUTH DAYTONA. FL 32121 TELEPHONE: (356) 767-4 74 FAX: (386) 767-M PAGE COPYRIGHT2M 1-30 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. SCREENED ENCLOSURES I SECTION 1 Table 1.2 Allowable Spans for Secondary Scree n'RoofjFrame Members Aluminum Alloy 6063 T-6 For Areas with Wind Loads up to 150 M.P.H. and Latitudes Below 30"-30'-00" North (Jacksonville, FL) A. Sections Fastened To Beams With Cllee Hollow Sections Tributary Load Width 'W'- Purlin Spacing 3'-6" 4'-0" 1 4'-6" 5'-0" 5'-6" 6'-0" 6'-8" Allowable Span'L' I bending'b' or deflection'd' 2" x 2" x 0.044" 7'-8" d 7'4" d T-0" d 6'-9" d 6'-6" b 6'-3" b 5'-11" b 2" x 2" x 0.055" 8'-l" d T-9" d T-5" d T-2" d 6'-11" d 6'-9" d 6'-6" b 3" x 2" x 0.045" 8'-8" d 8'-3" d 7'-11" d 7'-8" d 7'-5" d 7'-3" d 6'-11" d 2" x 3" x 0.045" 10'-9" d 10'-3" d 9'-9" b 9'-3" b 8'-10" b 8'-5" b 8'-0" b 2" x 4" x 0.050" 12'-2" b 11'-4" b 10'-8" b 10'-2" b 9'-8" b 9'-3" b 8'-9" b Snap Sections Tributary Load Width 'W' = Purlin Spacing 3'-6" 1 4'-0" 14'-6" 5'-0" 5'-6" 6'.0" 1 6'-8" Allowable Span 'L' I bending 'b' or deflection 'd' 2" x 2" x 0.044 8'-5" d 8'-1" d 1 T-9" d I T-6" d 1 T-3" d I T-m d I 2" x 3" x 0.045" 11'-7" d 11'A" dl 10'-8" dl 10'-4" dl 9'-11" bj 9'-6" bi 9'-0" b 2" x 4" x 0.045" 14'-8" d 14'-0" d 1 13'-6" d 1 12'-9" b 1 12'-2" b 11'. B. Sections Fastened Through Beam Webs Into Screw Rnssp-n Hollow Sections Tributary Load Width 'W' = Purlin Spacing 3'-6" 1 41-01,1 4'-6" 1 5'-0" 5'-6" t 1 6'-0" Allowable Span'L' I bending'b' or deflection'd' 2" x 2" x 0.044" 9'-2" b 8'-7" b 8'-l" b T-8" b 7'-4" lb 6'-11" b 6'-7" b 2" x 2"x 0.055" 9'-11" b 9'-4" b 8'-10" b 8'-4" b T-11" b 7'-7" b 7'-3" b 2" x 3" x 0.050" 12'-4" b 11'-7" b 10'-11" b 10'-4" b 9'-10" b 9'-5" b 8'-11" b 2" x 4" x 0.050" 13'-7" b 12'-8" b 11'-11" b 11'-4" b 10'-10" b 10'-4" b 9'-10" b Snap Sections Tributary Load Width 'W' = Purlin Spacing 3'-6" 1 4'-0" 1 4'-6" 1 51-0" 5'-6" 1 6'-0" 1 6'-8" Allowable Span'L' I bending'b' or deflection 'd' 2" x 2" x 0.0 " l-•--. 10'-11" b 10'-2" bi 9'-7" b 1 9'-l" b 1 8'-8" b 1 8'-4" b 1 T-11" b 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thickness shall be less than 0.040". 2. Spans are based on a minimum of 10# 1 Sq. Ft. for up to a 150 M.P.H. wind load.3. Span is measured from center of beam and upright connection to fascia or wall connection. 3. Span is measured from center of beam and upright connection to fascia or wall connection. 4. Purlin spacing shall not exceed 6'-8". For beam spans greater than 40'-0" the beam at the center purlin and one purlin for each 14'-0" on each side of the center purlin shall include lateral bracing as shown in detail 48'-0") span with purtins at 6'- 8" o.c. center purlin and (2) purlins each side of center purlin need lateral bracing. 5. Spans may be interpolated. CHECK TABLE 1.6 FOR MINIMUM UPRIGHT SIZE FOR BEAMS. Example: Max. 'L' for 2" x 4" x 0.050" hollow section fastened to beam with clips with 'li'V' = 5'-0"=10'-2" Lawrence E. Bennett, P.E. FL # 16644 CfVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) TOT-4 74 FAX: (386) 767-6556 I O NOT TO BE REePRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1 PAGE A "C7 I SECTION 1 SCREENED ENCLOSURES SCREEN I 'd' VARIES I 4" SHOW 1" x 2" O.B. BASE PLATE (TYP.) SECONDARY I 2" x (d - 2 ") x 0.063" ANGLE EACH SIDE OF COLUMN W/ #10 d S.M.S. SEE SCHEDULE NEXT PAGE) d CONCRETE ANCHOR SEE SCHEDULE NEXT PAGE) NOTE: DETAIL ILLUSTRATES TYPICAL 2" x 4" S.M.B. COLUMN 2" 5d CONNECTION MIN.) MIN.) SCREEN CONCRETE ANCHOR THRU ANGLE OR WITHIN 6" OF UPRIGHT IF INTERNAL SCREWS INTO SCREW BOSSES 2" x 2" x 0.063" PRIMARY ANGLE EACH SIDE 10 x 3/4" S.M.S. EACH SIDE SEE SCHEDULE NEXT PAGE) 5d' MINIMUM EDGE DISTANCE FROM EXTERIOR OF COLUMN TO OUTSIDE EDGE OF SLAB BOLT 0 5d DISTANCE 1/4" 1-1/4" 318" 1-7/8" GRADE 1-1/4" MIN. CONCRETE ANCHOR EMBEDMENT TYPICAL S.M. OR SNAP SECTION COLUMN 2) #1gpx 3/4" S.M.S. EACH SIDE PRIMARY 2" x 2" x 0.063" ANGLE 1" x 2" BASE PLATE (TYP.) 4. v Q 1-1/4" MIN. CONCRETE NOTE: SELECT CONCRETE ANCHOR EMBEDMENT ANCHOR FROM TABLE 9.1 6" (MAX.) 6" (MAX.) 3000 P.S.I. CONCRETE MAX. SPACING 24" O.C. FOR BOTH SIDES FRONT VIEW 2" x 4" OR LARGER SELF MATING OR SNAP SECTION POST TO DECK DETAILS SCALE: 3" = 1'-0" NOTE: FOR SIDE WALLS OF 2" x 4" OR SMALLER ONLY ONE ANGLE IS REQUIRED. Lawrence E. Bennett, P.E. FL # 16W CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (366) 7674774 FAX: (M) 767.66M PAGE Q COPYRIGHT 2004 1 -50 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E. SECTION 1 1 SCREENED ENCLOSURES Table 1.3 Allowable Post / Upright Heights for Primary Screen Wall(Frame Members Aluminum Alloy 6063 T-6 ` For 3 second wind gust at velocity of 120 MPH or an applied load of 14 # / sq. ft." Hollow Sections Tributary Load Width 'W' = Upright Spacing 3'-0" 1 4'-0" 1 5'-0" 1 6'-0" 1 7'-0" 1 8'-0" 9'-0" Allowable Height 'H' 1 bending b' or deflection 2" x 2" x 0.044" 8'-0" b 7'-3" b 1 6'-6" b 1 5'-11" b 1 5'-6" b 1 5'-1" b 4'-10" b 2" x 2" x 0.055" 9'-1" b 7'-11" b 7'-1" b 6'-5" b 1 5'-11" b 5'-7" b f 5'-3" b 2" x 3" x 0.045" 11'-3" b 9'-9" b 8'-9" b 7'-11" b 7'-5" b 6'-11" b 1 6'-6" b 2" x 4" x 0.050" 12'-5" b 10'-9" b 9'-7" b 8'-9" b 8'-l" b 7'-7" b 7'-2" b Self Mating Sections Tributary Load Width W = Upright Spacing 3'-0" 4'- 0" 5'-0" 1 6'-0" 7'-0" 1 8'-0" 9'-0" Allowable Helght'H' I bending'b' or deflection'd' 2" x 4" x 0.044 x 0.100" 16'-11" b 14'-8" b 13'-l" b 111'-11" b 11'-1" b 10'-4:- b 9'-9" b 2" x 5" x 0.050" x 0.100" 20'-11" b 18'-1" b 16'-2" b 14'-9" b 13'-8" b 12'-10" b 12'-1" b 2" x 6" x 0.050" x 0.120" 24'-2" b 20'-11" b 18'-9" b 17'-1" b 15'-10" b 14'-10" b 13'-11" b 2" x 7" x 0.055" x 0.120" 27'-3" b 23'-7" b 21'-1" b 19'-3" b 17'-10" b 16'-8" b 15'-9" b 2" x 7" x 0.055" w/ Insert 36'-3" b 31'-4" b 28'-1" b 25'-7" b 23'-9" b 22'-2" b 20'-11" b 2" x 8" x 0.072" x 0.224" 35'-2" b 30'-6" b 27'-3" b 24'-10" b 23'-0" b 21'-6" b 1 20'-4" b 2" x 9" x 0.072" x 0.224" 38'-2" b 33'-0" b 29'-6" b 26'-11" b 2471" b 23'-0" b I 2Z-0" b 2" x 9" x 0.082" x 0.310" 41'-10" b 36'-3" b 32'-5" b 1 29'-7" b 27'-5" b 25'-8" bi 24'-2" b 2" x 10" x 0.092" x 0.369" 1 50'-0" b 437 b 38'-11" bj 35'-7" b 32'-11" b 30'-10 b 29'-1" b Snap Sections Tributary Load Width ' W'= Upright Spacing 3'-0" 1 4'-0" . 1 5'-0" -1- - 6'-0" 3 7'-0"1 8'-0" 9'.0" Allowable Helght'H' 1 bending b' or deflectlon'd' 2" x 2" x 0.044" 9'-11" b 8'-7" b 7'-8" b T-0" b 6'-6" b 6'-1" b 5'-9" b 2" x 3" x 0.045" 1A 1 12'-9" b 11'-0" b 9'-10" b 9'-0" b 8'-4" b 7'-10" b 7'-4" b 2" x'4" x 0.045" 15'-7" b 13'-6" b 12'-1" b 11'-0" b 10'-2' b 9'-7" b 8'-11" b 2" x 6" x 0.062" 26'-5" b 22'-10" b 20'-5" b 18'-8" b 17'-3" b 16'-2" b 15'-3" b 2" x 7" x 0.062" N 29'-5" b 25'-5" b 22'-9" b 20'-9" b 19'-3' b 17'-11" b 16'-11" b ror aliowaDle heights at wind velocities other than 120 MPH, see conversion table 1A on the specification page for tables at the beginning of this section and example below. Note: 1. Thicknesses shown are "nominar industry standard tolerances. No wall thickness shall be less than 0.040". 2. Using screen panel width _W'select upright length'H'. 3. Above heights do not Include length of knee brace' Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 4. Site specific engineering required for pool enclosures over 20' in mean roof height. 5. Height is to be measured from center of beam and upright connection to fascia or wall connection. 6. Chair rails of 2" x 2" x 0.044" min. end set @ 36" in height can be considered as residential guardrails provided they are attached with min. (3) #10 x 1-1/2" S.M.S. into the screw bosses and do not exceed 8'-0" In span. 7. Heights may be interpolated. CHECK TABLE 1. 6 FOR MINIMUM UPRIGHT SIZE FOR BEAMS. IF SPANS FOR' C' EXPOSURE CATAGORY AND/OR WINDZONES OTHER THAN 120 MPH ARE REQUIRED, SEE EXAMPLE ON SPECIFICATION PAGE FOR TABLES AT THE BEGINNING OF THIS SECTION. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 787- 4774 FAX: (386) 767- 6850 PAGE COPYRIGHT 2004 1. 58 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. SCREENED ENCLOSURES SCREWS OR THRU-BOLTS SEE SECTION 9) 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS WITHIN 6" OF EACH SIDE OF EACH POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL SECTION 1 POST SIZE 2" x 4" MAX. MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE POST TO PLATE TO CONCRETE DETAIL SCALE: 3" = V-0" 2" x 2" x 0.063" ANGLE EACH SIDE ATTACH TO POST AND CONCRETE @ LOAD BEARING WALL W/ (2) MIN. S.M.S. (PER SECTION 9) EACH SIDE MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE ANGLES AS SHOWN ABOVE MAY BE USED TO CONNECT CHAIR RAILS AND PURLINS 4- POST SIZE 2" x 4" MAX. SEE TABLE) 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS 6" MAX. EACH SIDE OF EACH POST AND @ 24" O.C. MAX. OR THROUGH ANGLE AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL ALTERNATE POST TO BEAM AND PLATE TO CONCRETE DETAIL SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4774 FAX: (356) 767.0556 I O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1 PAGE 1 A 7 I SCREENED ENCLOSURES I SECTION 1 Table 1.4 Allowable Post / Girt ! Chair Rail Spans, Header Spans & Upright Heights for Secondary Screen Wall Frame Members Aluminum Alloy 6063 T-6 For 3 second wind gust at velocity of 120 MPH or an applied load of 14 fl / sq. ft.* A. Sections As Horizontals Fastened To Posts With Clios Hollow Sections Tributary Load Width'W' 3'-6' 1 4'-0" 4'-6" 1 5'-0" 1 51-6" Allowable Heights 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 6'-10" d 6'-6" b 6'-1" b 5'-9" b 5'-6" b 1 5'-3" b 5'-0" b 2" x 2" x 0.055" 7'-3" d 6'-11" d 67b 6'-4" b 6'-0" b 5'-9" b T-6" b 3" x 2" x 0.045" 7'-9" d 7'-5" d T-l" d 6'-10" d 6'-7" b 6'-4" b 5'-11" b 2" x 3" x 0.045" 9'-4" b 8'-9" b 8'-3" b T-10" b T-5" b 1 7'-2" b 6'-9" b 2" x 4" x 0.050" 10'-3" b 9'-7" b 9'-0" b 8'-7" b 8'-2" b 1 T-10" b T-5" b Snap Sections I Allowable Heights 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 1 T-6" d 1 T-2" d 1 6'-11" d 1 6'-8" b 6'-4" b 1 6'-1" b 1 5'-9" b B. Sections As Horizontals Fastened To Posts Through Sldr- Info Seraw ReSSeS Hollow Sections Tributary Load Width 'W' 3'- 6' 1 4'-0" 41 4'-6" 1 5'-0" 1 5'-6" 1 6'-0" 1 6'-8" Allowable Heights 'H' / bendlng 'b' or deflection 'd' 2" x 2" x 0.044" / 7'-9" b 1 T-3" V b 6'-10" b 1 6'-6" b 6'-2" b 5'-11" b 5'-7" b 2" x 2" x 0.055" 8'-5" b T-11" b T-5" b 7'-1" b 6'-9" b 6'-5" b 6'-1" b 3" x 2" x 0.045" 9'-3" bi 8'-8" b 8'-2" bi 7'-9" 7'-5" b 7'-1" b 6'-8" b 2" x 3" x 0.045" 10'-5" b 9'-9" ` b 9-2*'b 8'-9" jb 8'4" b 7'-11" b 7'-7" b 2" x 4" x 0.050" 11'-6" b 10'-9" b 10'-l" b 9'-7" 9'-2" b 8'-9" b 1.-4" b Snap Sections Allowable Hei hts 'H' / bending 'b' or deflection d' 2" x 2" x 0.044" 9'-2" b 1 8'-7" b 1 8'-1" b 1 T-8" b 1 7'4" b 1 T-0" b 6'-8" b ror ahowame heights at wind velocities other than 120 MPH, see conversion table 1A on the specifications for tables page at the beginning of this section and example below. Notes: 1. Thicknesses shown are "nominal" industry standard tolerances. No wail thickness shall be less than 0.040". 2. Using screen panel width 'W' select girt lengths. 3. Site specific engineering required for pool enclosures over 20' in mean roof height. 4. Span is to be measured from center of beam and upright connection to fascia or wall connection. 5. Chair rails of 2" x 2" x 0.044" min. and set @ 36" in height can be considered as residential guardrails provided they are attached With min. (3) #10 x 1-1/2" S.M.S. into the screw bosses and do not exceed 8'-0" in span. 6. Girt spacin§rshall not exceed 6'-8". 7. Spans may be interpolated. IF HEIGHTS FOR'C' EXPOSURE CATAGORY AND/OR WINDZONES OTHER THAN 120 MPH ARE REQUIRED, SEE EXAMPLE ON SPECIFICATION PAGE FOR TABLES AT THE BEGINNING OF THIS SECTION. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: ( 385) 767-4T74 FAX: ( 386) 767-65M I O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1 PAGE 1 - 59 I SECTION 1 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS 6" MAX. EACH SIDE OF EACH POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE SCREENED ENCLOSURES POST SIZE 2" x 4" MAX. SIDE WALL POST TO PLATE TO CONCRETE DETAIL SCALE: 3" = 1'-0" 1" x 2" EXTRUSION ANCHOR TO CONC. W/ CONC. ANCH. 6" MAX. EA. SIDE OF EA. POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 MIN. 3-1/2" SLAB 2500 P.S.I. CONC. 6 x 6 - 10 x 10 W.W.M. OR FIBER MESH CONC. 2" x 2", 2" x 3" OR 2" x 4" HOLLOW SECTION SEE TABLES) MIN. (3) #1)0 x 1-1/2" S.M.S. INTO SCREW BOSSES MASONRY ANCHOR @ 6" EA. SIDE OF POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL HOLLOW POST TO BASE DETAIL SCALE: 3" = 1'-0" POOL ENCLOSURE UPRIGHT TO DECK ANCHOR REQUIREMENTS General Notes and Specifications: 1. The uplift load on a pool enclosure upright is calculated as 1/2 the beam span x the beam spacing x the screen load of 7# / Sq. Ft. EXAMPLE: FOR A 2" x 6" BEAM WITH A SPAN OF 23' AND A BEAM & UPRIGHT SPACING OFT USE: 1/2 x 17'-11" x 7' x 10# / Sq. Ft. = 627.2# UPLIFT 2. Table 1.6 of this manual uses the worst case loads for all cases. 3. In all cases there must be a primary anchor within 6" of each side of the upright. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (388) 767.4774 FAX: (386) 767-M PAGE vo ( O COPYRIGHT 2804 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SCREENED ENCLOSURES I SECTION 1 Table 1.6 Minimum Upright Sizes and Number of Screws for Connection of Roof Beams to Wall Uprights or Beam Splicing Beam Size Upright Size Minimum Purlin, Girt Knee Brace Size"' Deck Anchors Notes Minimum Number of Screws' Beam Stitching Screw 24" O.C. 8 x'/:" 10 x'/a" 12 x %" 2" x 3" 2" x 3" 2" x 2" x 0.044" 2 Full Lap 6 4 4 2" x 4" 2" x 3" 2" x 2" x 0.044' 2 Full Lap 8 6 4 8 2" x 4" 2" x 4" 2" x 2" x 0.044" 2 Full Lap 8 6 4 10 2" x 5" 2" x 3" 2" x 2" x 0.044" 2 Full Lap 8 6 4 8 2" x 6" 2" x 3" 2" x 2" x 0.044" 4 Full Lap 10 8 6 10 2" x 6` 2"x 4" 2" x 2" x 0.044" 4 Partial La 10 8 6 10 2" x 7" 2" x 4" 2" x 2" x 0.044" 4 Partial LaR 14 12 10 12 2" x 8" 2" x 5" 2" x 3" x 0.044" 6 Partial Lap 16 14 12 14 2" x 9" 2" x 6" 2" x 3" x 0.045" 6 Partial Lap,18 16 14 14 2" x 9"" 2" x 7" 2" x 4" x 0.050" 8 Partial Lapf 20 18 16 14 2" x 10" 2" x 8" 1 2" x 4" x 0.050" 10 Partial Lap I 20 18 16 14 Screw Size Minimum Distance and Spacing of Screws Gusset Plate Thickness Edge To Center Center To Center Beam Size Thickness 8 5/16" 5/8" • 2" x 7" x 0.055" x 0.120" 1/16" = 0.063" 10 3/8" 3/4" 2" x 8" x 0.072" x 0.224" 1/8" = 0.125" 12 1/2" 1" 2" x 9" x 0.072" x 0.224" 1/8" = 0.125" 14 or 114" 314" 1-1'2" 2" x 9" x 0.082" is 0..306" 118" 5/16" 7/8" 1-3/4" 2" x 10" x 0.092" x 0.369" 1 114" = 0.25" 3/8" 1" i 2„ Keters to each side of the connection of the beam and upright and each side of splice connection. 4. 0.082" wall thickness, 0.310" flange thickness Note: 1. Connection of 2" x 6" to 2" x 3" shall use a full lap cut or 1/16" gusset plate. 2. All gusset plates shall be a minimum of 5052 H-32 Alloy or have a minimum yield strength of 23 ksi. 3. For beam splice connections the number of screws shown is the total for each splice with 1/2 the screws on each side of the cut. 4. The number of screws is based on the maximum allowable moment of the beam. 5. The number of deck anchors is based on RAWL R Tapper allowable load data for 2,500 psi concrete and / or equal anchors maybeused. The number shown is the total use 1/2 per side. 6. Hollow splice. connections can be made provided the connection, is approved by the engineer. 7. If a larger than minimum upright is used the number of screws is the same for each splice with 1/2 the screws on each side of the cut. 8. All beam to uprightrconnections for 2" x 7" beams or larger shall have an internal or external gusset plates. Gusset plates are required for mansard or gable splice connections. 9. For gusset plate connections 2" x 9" beams or larger use 3/4" long screws. 10. The side wall upright shall have a minimum beam size as shown above, ie., a 2" x 4" upright shall have a 2" x 3" beam. 11. Connect beam to upright w/ H-bar, gusset plate, or angle clips for each splice with 1/2 the screws on each side of the cut. 12, For girt size use upright size (i.e. 2" x 6"). Read the 2" x 6" beam row for min. girt of 2" x 2" x 0.044". Table 1.7 Minimum Size Screen Enclosure Knee Braces and Anchoring Required Aluminum 6063 T-6 Brace Length Extrusion Anchoring System 0' - 2'-0" 2" x 2" x 0.044" 2" H-Channel With 3 #10 x 1/2" EACH SIDE To T-0" 2" x 3" x 0.045" 2" H-Channel With_(3) #10 x 1/2" EACH SIDE - To 4'-6" 2" x 4" x 0.044" x 0.12" 2" H-Channel With (4) 3/4" long screws - ' size to be determined by beam size, see table 9.6) See Table 1.6 For Number And Size Of Screws) Note: 1. For required knee braces greater than 4'-6" contact engineer for specifications and details. 2. Cantilever beam detail shown on page 1-32 shall be used for host structure attachment when knee brace length exceeds 4'-6". COPYRIGHT 2W4 Lawrence E. Bennett, P.E. FL # 16W CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (366) 767-4774 FAX: (366) 767.65% PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E. 1 1 -61 SECTION 1 2"x4"OR2"x6" SELF MATING BEAM 1" x 2" SNAP SECTIONS ATTACHED TO 2" x 2" W/ 10 x 1-1/2" S.M.S. @ 24" O.C. OR CONTINUOUS SNAP SECTIONS OR 2" x 3" (4) SPLINE GROOVE SECTION 1" x 2" OPEN BACK FASTENED TO POST W/ (2) #10 x 1-1/2" S.M.S. ATTACH 2" x 2" PURLINS TO SELF MATING BEAMS W/ (2) 10 x 1-1/2" S.M.S. INTO SCREW BOSSES SCREENED ENCLOSURES MINIMUM POST SIZES REQUIRED FOR EACH BEAM SIZE (SEE TABLE 1.6) i I I r® r- ALTERNATE FLAT ROOF I I SELECT FASTENER SIZE, NUMBER AND PATTERN SEE TABLE 1.6 & 9.5A OR 9.56) 2" x 3" HOLLOW OR SNAP SECTION SLOPING BEAM TO UPRIGHT CONNECTION DETAIL (PARTIAL LAP) SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214360. SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767-4774 FAX: (366) 767-M PAGE Q COPYRIGHT 2084 1-$ NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. I" SCREENED ENCLOSURES SECTION 1 SEE TA PURLINS (TYP.) SCREEN (TYP.) CABLE CONNECTION SEE DETAILS SECTION 1) ALTERNATE CABLE 1" x 2" (TYP.) GRADE K-BRACING (OPTIONAL) — / _ CABLE CONNECTION GIRT (TYP.) / (SEE DETAILS SECTION 1) TYPICAL DOME ROOF - ELEVATION SCALE: N.T.S. EXISTING STRUCTURE ALUMINUM BEAM TABLE 1.1 OR 1.8) SIZE MEMBERS PER APPROPRIATE TABLES # H i 7 K-BRACING (OPTIONAL) GIRT (TYP.) SCREEN (TYP.) SW ALUMINUM COLUMNS (TYP.) TABLE 1.3 OR 1.6) PERIMETER WALLS FRAMING 1" x 2" (TYP.) (SEE TABLES 1.3 AND 1.4) TYPICAL DOME ROOF - ISOMETRIC SCALE: N.T.S. CONNECTION DETAILS AND NOTES ARE FOUND IN THE SUBSEQUENT PAGES. RrcFR WALL WHERE UIRED LINS (TYP.) ONAL ROOF BRACING SCHEMATIC SECTION 1) LE BRACING Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767.4774 FAX: (388) 767.6= COPYRIGHT 2004 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E. 1-3 SCREENED ENCLOSURES PURLIN (T"^ SCREEN (1 SEE TA v-u<-v SECTION 1 CABLE CONNECTION SEE DETAILS SECTION 1) GIRT (TYP.) 1" x 2" (TYP.) GRADE CABLE CONNECTION SEE DETAILS SECTION 1) TYPICAL TRANSVERSE GABLE ROOF - ELEVATION SCALE: N.T.S. EXISTING STRUCTURE W SIZE MEMBERS PER APPROPRIATE TABLES L H K-BRACING (OPTIONAL) RISER WALL WHERE REQUIRED PURLIN (TYP..) ALUMINUM BEAM TABLE 1.1 OR 1.8) DIAGONAL ROOF BRACING SEE SCHEMATIC SECTION 1) ALUMINUM COLUMNS (TYP.) } TABLE 1.3 OR 1.6) / SCREEN (TYP.) SW GIRT (TYP.) PERIMETER WALLS FRAMING 1" x 2" (TYP.) TABLE 1.3 OR 1.4) CABLE BRACING TYPICAL TRANSVERSE GABLE ROOF -.ISOMETRIC SCALE: N.T.S. CONNECTION DETAILS AND NOTES ARE FOUND IN THE SUBSEQUENT PAGES Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214365, SOUTH DAYTONA, FL 32121 TELEPHONE: (356) 767-4774 FAX: (356) 767-6&% I O NOT TO BE REPaR`OOUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E.. 1 PAGE 1-5 1 SCREENED ENCLOSURES SECTION 1 5) #10 S.M.S. (MIN.) - 1/8" x 1-1/2" x 8" FLAT BAR e e e e e 0.125" PLATE OUT ON 459 ANGLE EYE -BOLT OR TURNBUCKLE FOR CABLE TENSION STAINLESS STEEL (SEE TABLE) PERIMETER FRAMING MEMBER TYPICAL CABLE CONNECTIONS AT CORNER - DETAIL 1 SCALE: 3" = 1'-0" A ALTERNATE: USE (1)1/4" x 1-1/4" FENDER WASHER EACH FRAME MEMBER SIDE OF r EITHER A OR B 1" x 2" x 0.125" CLIP AND (4) B MIN. (2) CLAMPS REQUIRED10x3/4" S.M.S. EACH SIDE FOR CABLES ®®®® (NP•) MIN. 1/4" EYE BOLT. WELD EYE CLOSED (TYP.) ALTERNATE TOP CORNER OF CABLE CONNECTION - DETAIL 1A SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214366, SOUTH DAYTONA. FL 32121 TELEPHONE: (356) 757.4774 FAX: (356) 757.65M Q COPYRIGHT 2W4 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1 "w 1 SECTION 1 SCREENED ENCLOSURES LAB MIN. (2) 1/4' OR 5/16" x 1-3/4" CONCRETE ANCHORS ALTERNATE CLIP: 3" ASTM A-36 PRESSED STEEL CLIP TYPICAL CABLE CONNECTION AT SLAB DETAIL - DETAIL 2 SCALE: 3" = l'-0" ANCHOR PER TABLE 9-1A MIN. SHEAR 607# FOR 3/32" CABLE AND 902# FOR 1/8" CABLE FOR 3/32" CABLE 5/16" x 2" CONCRETE ANCHOR W/ CABLE THIMBLE AND WASHER 3-1/2" (4" NOMINAL) SLAB (MIN.) SLAB FOR 1/8" CABLE SHALL HAVE A THICKENED EDGE TO ACHIEVE 5d MIN. AND A 3/8" x 2" ANCHOR 1 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE ALTERNATE CABLE CONNECTIONS AT FOUNDATION - DETAIL 2A SCALE: 3" = l'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4774 FAX: (388) 7674M PAGE COPYRIGHT 204 1-42 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. SECTION 1 SCREENED ENCLOSURES ADDITIONAL FASTENING, NUMBER OF FASTENERS PER TABLE 1.6 & 9.5 EXCEPT ALL SHADED LOCATIONS SHALL BE FILLED MINIMUM OF ALL OUTER LOCATIONS 10) #8 x 1/2" S.M.S. EACH SIDE OF BEAM / POST 1" x 2" OPEN BACK ATTACH TO 2" x 2" W/ #10 x 1-1/2" S.M.S. @ 24" O.C. OR CONTINUOUS 2" x 3" (4) SPLINE GROOVE SECTION CONNECT 2"x 2" OR 2" x 3" TO BEAM W/ MIN. OF (3) 10 x 1-1/2"S.M.S. INTO SCREW BOSSES Y EXISTING 2" x 6" SELF MATING BEAM 10 x 3 112" S.M.S. 16" O.C. PROPOSED 2" x 3" x 0.050" SMOOTH SIDE DOWN 1/8" x 2-3/4" x 8" GUSSET EACH SIDE OF POST AND BEAM W/ 6) #8 x 1/2" S.M.S. EXISTING 2" x 4" ADDITION OF 2" x 3" TO EXISTING 2" x 6" S.M.B. SCALE: 3" = T-O" Lawrence E. Bennett, P.E. FL # 16644 CW ENGINEER- DEVELOPMENT CONSULTANr P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: rAM 7ST-4TT4 FAX; (386) 767-656 PAGE COPYRIGHT Z004 1-14 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. SCREENED ENCLOSURES CONNECTOR MAY BE (2) ANGLES, INTERNALLU' CHANNEL OR EXTERNALLU' CHANNEL EACH SIDE OF CONNECTING BEAM W/ SCREWS (PER SECTION 9) CARRIER BEAM SEE TABLE 1.5) MINIMUM NUMBER S.M.S. 3/4" LONG REQUIRED EQUAL TO BEAM DEPTH SEE SECTION 9) SECTION 1 EXTRUSIONS W/ INTERNAL SCREW BOSSES MAY BE CONNECTED W/ (3) #10 x 1-1/2" INTERNALLY PRIMARY BEAM SEE TABLE 1.1 OR 1.8) CARRIER BEAM TO BEAM CONNECTION DETAIL SCALE: 3" = 1'-0" ALTERNATE: 1"x2", 1"x3"OR2"x2" ATTACHED TO WALL W/ #10 x 2" S.M.S. @ 16" O.C. HOST STRUCTURE MASONRY OR FRAMED WALL SELECT FASTENERS FROM SECTION 9 TABLES) PRIMARY OR MISC. FRAMING BEAM (SIZE PER TABLES) ANGLE OR RECEIVING CHANNEL 44. BEAM TO WALL CONNECTION: 2) 2" x 2" x 0.060" EXTERNALLY MOUNTED ANGLES ATTACHED TO WOOD FRAME WALL W/ MIN. (2) 3/8" x 2" LAG SCREWS PER SIDE OR TO CONCRETE W/ (2)1/4" x 2-1/4" ANCHORS OR MASONRY WALL ADD (1) ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" ALTERNATE CONNECTION: 1) 1-3/4" x 1-3/4" x 1-3/4" x 1/8" INTERNAL U-CHANNEL ATTACHED TO WOOD FRAME WALL W/ MIN. (3) 3/8" x 2" LAG SCREWS OR TO CONCRETE OR MASONRY WALL W/ (3) 1/4" x 2-1/4" ANCHORS OR ADD (1) ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" BEAM TO WALL CONNECTION DETAIL SCALE: 3" = l'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER- DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (356) 7874774 FAX: (386) 757.6556 PAGE Q COPYRIGHT 2W4 I 1 _ NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SCREENED ENCLOSURES SECTION 1 1/4" x 6" RAWL TAPPER THROUGH 1" x 2" AND ROWLOCK INTO FIRST COURSE OF BRICKS ALTERNATE CONNECTION OF SCREENED ENCLOSURE FOR BRICK OR OTHER NOW STRUCTURAL KNEE WALL 1" WIDE x 0.063" THICK STRAP @ EACH POST FROM POST TO FOOTING W/ (2) #10 x 3/4" S.M.S. STRAP TO POST AND 1) 1/4" x 1-3/4" CONCRETE ANCHOR TO SLAB OR FOOTING ALUMINUM FRAME SCREEN WALL CAP BRICK BRICK KNEEWALLTYPE'S' MORTAR REQUIRED FOR LOAD BEARING BRICK WALL 4" (NOMINAL) PATIO CONCRETE SLAB (SEE NOTES CONCERNING FIBER MESH) 3) #30 BARS OR (1) 50 BAR W/ 2-1/2" COVER TYP.) BRICK KNEEWALL AND FOUNDATION FOR SCREEN WALLS SCALE: 3/4" = 1'-0" 2'-0" MIN 3-1/2" (TYP. 2 #3 BAR CONT. OR 1 #5 BAR CONT. BEFORE SLOPE I ALL SLABS) ol 8„ 1 #5 BAR CONT. 3 #3 BAR CONT. OR TYPE I TYPE II TYPE III FLAT SLOPE / NO FOOTING MODERATE SLOPE FOOTING STEEP SLOPE FOOTING 0-2" / 12" 2" / 12" - V-10" > V-10" Notes for all foundation types: 1. No footing required except when addressing erosion until the slab width in the direction of the primary exceeds 32 ft., then a Type If footing is required under the load bearing wall only unless the side wall exceeds 16 ft. in height or the enclosure is in a "C" exposure catagory in which case a Type II footing is required for all walls. 2. The foundations shown are based on a minimum soil bearing pressure of 1,500 PSF. Bearing capacity of soil shall be verified, using a pocket penetrometer, field soil test, or by a soil testing lab, to be above 1,500 PSF prior to placing the slab. 3. The slab / foundation shall be cleared of debris and roots and compacted prior to placement of concrete. 4. Monolithic slabs and footings shall be minimum 2,500 psi concrete with 6 x 6 - 10 x 10 welded wire mesh or crack control fiber mesh. Fibermesh ® Mesh, InForce"m e3 "A (Formerly Fibermesh MD) per maufacturers specification may be used in lieu of wire mesh. 5. If local building codes require a minimum footing, use Type II footing or footing sections required by local code. Local code governs. SLAB -FOOTING DETAILS SCALE: 3/4" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214363, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767-4774 FAX: (386) 757 6556 COPYRIGHT 2004O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1 PAGE 1-55 I