HomeMy WebLinkAbout221 Woodmere Blvd (3)Permit # :UJ
Job Address:
I "
Description of Work:
Historic District:
r CITY OF SANFORD PERMIT APPLICATION
Date: "L ` 05
Kd A:Q- §!A VND d
Zoning: Value of Work: S_ IL
Permit Type: Building Electrical Mechanic Plumbing Fire Sprinkler/Alarm Pool
fi
Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole
Mechani : Residenti Non -Residential Replacement ew (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair- Residential or Commercial `
Occupancy T esidentia Commercial Industrial Total Square Footage: 1-4(0(0
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X)
Parcel #: "(o - 20 - 3 t . 0E Q0 c m 1 c) (Attach Proof of Ownership & Legal Description)
Owners Name&Address: CTQA4 ,0-0 t(Y16 R'2 1e
Contractor Name & Address: -A-P 1.
9 9A
Tt ne;R Fax: ,( O-7) r % C tac a on: [r Phone` 19
Bonding Company: N[1k
Address: - - MAD M0 1
Mortgage Lender:
Address:
Architect/Engineer: U•Phone:
r •
Address: ! Fax:.:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws: regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR.I'l+.YfNG
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
f
NOTI :In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may din the ublic records of
this county, and there may be additional permits required from other governmental entities such as water management dis to ag s or federal agnrr:irs.
Acceptance of permit is verification that 1 uill notify the owner of the property of the requirements of Florid ' n U S
Signature of Owner/Agent Date Sit ;
ure
of Contractor/Agen Date
ItB_ERT G. SO,
Print Owner/Agent's Name Print ontracior/Agent's Name
AAA A&
Signature of Notary -State of Florida Date Signature of Notary -State of F da Date
Owner/Agent is _ Personal].- Known to Me or Contractor/Agent i Personally Known to Me or
Produced ID Products ID
APPLICAI ION APPRO\-ED BY: BldI
6 d /
Zoning: L;:::rie5: I-D: initial &
Date) (Initial & Date) (Initial & Date) (Initial & Date) Special
Conditions: 2
5 3 roo .ra-eu'L E3
MY
COMMISSION # DO 212893 EXPIRES:
June 14, 21X17 Mod
Thro Notary PUCNt UrWrn riten
i
I
6Fx „b5 aX f'
176
1 IjEo az
x
wm
7
X- C.V
m lu nq W,i
14' rl'
Ix-1w J
I.
ha .2-7idezo me
7 S X38
SUS'2 O/C j\ 2
rICwlen
LnL P-1 I ezowr
ffmcg—o'-'140 wo
01Rza (2#
y i)
f
GO CJ
35
L
w.nLcR
26a A
HEATING Alf
a o. Boxx
CUSTOMER
1CB ADDRESS
PIAN No.
DRAhN BY
APPROVED BY
j VOLTAGE
DATE 3 D
NQs. Maltc•
Permit. Number--------------------
Parcel Identilicatlon Number M•,o 05 • Cp, pt p
Prepared by:
THIS IN Igo11 lRONgIIIIIIl.goo1O111consul a UMPREPARnNAMEu
r1 1 ` MARYANNE NMI CLERK OF CIRCUIT COURT DQ - V
2._. SENINOLE COUNTY Rgturn to: '
PK 05643 P6 1624 DEL -AIR
HEATING & AIR COND. CLERK' S #1 2065640536 109 COMMERCE
STREET, SUITE 1101 RF.8AS
89t48>144 AN REMRDED tRDINB. FFEES PEES 1111.40. LAICEMARY, FLORIDA
32746 RECORDED BY. L NcKinley NO`I`ICC.
OF C0imvirz GEiVIENT State' of County
o o
e The undersigned hereby
gives notice that improvements) will be made to certain real property, and in accordan with Chapter 713, Florida Statutes, the following iriformation is provided in this Notice of Commencement. 1. Description of
property (Legal description bf the property, and street address if available) ener Nk- v
tol21; 2.. General descripti`
on1 of.lmprovement(s) 3. Owner Informatlo
Name Q gSLo
c•>,1So n V1J1'C-ei2.vLQ. ' Address oD a ` Fax Number Telephone
NumberQA 3'
1) 3.23 38G7 rn--e S; D ed.
32-f 73 Interest in Property: 4• : Fee SimpleTitleHolder (if other than owner shown above) Name Address WATelephone
Number Fax Number 5• .
Contra cio
ID EL -AIR HEATING & AIR COND. Name 109 COMMERCE
STREET, SUITE 1101 Address Telephone Number (-40-1) LAKE MARY, FLORIDA32746FaxNumberSuretY.(i f
any) Name y ' CERTIFIED
COPY
Address
Telephone NumberFaxNumberMARYANNE
MORSE Amount of bond $
CLERK OF CIRCUIT COURT 7• Y.Lender (
if.any) _ LORIDA Name. Address Telephone
Number
EP ER Fax Number MAR.
4 0 ZOOS 8. Persons withinthe
State of Florida designated by Owner upon whom notices or other d served as providedby §713.13(1)(a)7., Florida Statutes. ocuments may be Name. Address TelephoneNumber
Fax Number 9•:
in addition
to himself or herself, Ow Provided in §713.
13(I)(ner des 9nales the following to receive a COPY 's Notic b), Florida. Statutes, opy othe Lienore . Name 1 f . Address / Telephone
Number K Fax
Number 10. k'
xpiratlon date of
rJOilce
of commencement (the expiration dale is one year from th unless a different date isspecified) a date of recordirn O Y O L en.>`
l
C' S Ca Date Signed Sign ture of
Owner No
e: per §713.13(1)(g), !'owner must sign ...and no orherstead." one else
may be permitted to sign ii Sworn. nd. sub who is. '
P as identification. .
20JD5— by Signature
of to
appear below)
Form Revised:
12100 for 19_
to 20 moo • 1 t; MIRINDA C.
TURNER . 14 MY
COMMISSION # DO 212893
EXPIRES: June 14 2007 Bonded
Thru No" Public Underwriters
Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1
F +r »
r 4
JCHr4SON. CFA. A SA
f
r0&
S
PROPERTY
APPRAISER
11
rr
9[MIIVOLECOUNTYFL
nT a<
1 101 E. FIRST ST
SANFOR0,FL32771 1468
407-665-7506
Yr•
1
l
1 y, C"'
GALE Pl
2005 WORKING VALUE SUMMARY
GENERAL
Value Method: Market
06-20-31-505-OEOO
Number of Buildings: 1
Parcel Id: 0110 Tax District: S1-SANFORD Depreciated Bldg Value: $42,036
Owner: JOHNSON Exemptions: 00- Depreciated EXFT Value: $1,061
MARCELENE HOMESTEAD Land Value (Market): $10,680
Address: 221 WOODMERE BLVD Land Value Ag: $0
City,State,ZipCode: SANFORD FL 32773 Just/Market Value: $53,777
Property Address: 221 WOODMERE BLVD SANFORD 32773 Assessed Value (SOH): $38,741
Subdivision Name: WOODMERE PARK 2ND REPLAT Exempt Value: $25,000
Dor: 01-SINGLE FAMILY Taxable Value: $13,741
Tax Estimator
2004 VALUE SUMMARY
SALES
Tax Amount(without SOH): $510
Deed Date Book Page Amount Vac/Imp
2004 Tax Bill Amount: $259
WARRANTY DEED 04/1981 01340 1383 $8,400 Improved
Save Our Homes (SOH) Savings: $251
2004 Taxable Value: $12,613
Find Comparable Sales within this Subdivision
DOES NOT INCLUDE NON -AD VALOREM
ASSESSMENTS
LAND
Land Unit Land LEGAL DESCRIPTION PLAT
Land Assess Method Frontage Depth Units Price Value LEG LOT 11 BLK E WOODMERE PARK 2ND
FRONT FOOT &
60 114 000 200.00 $10,680
REPLAT PB 13 PG 73
DEPTH
BUILDING INFORMATION
Bid Num Bid Type Year Bit Fixtures Base SF Gross SF Heated SF Ext Wall Bid Value Est. Cost New
1 SINGLE FAMILY 1961 3 858 1,266 858 CONC BLOCK $42,036 $55,311
Appendage / Sgft OPEN PORCH FINISHED / 56
Appendage / Sgft CARPORT UNFINISHED / 220
Appendage / Sgft ENCLOSED PORCH UNFINISHED / 102
Appendage / Sgft OPEN PORCH UNFINISHED / 30
EXTRA FEATURE
Description Year Bit Units EXFT Value Est. Cost New
ALUM SCREEN PORCH W/CONC FL 1979 180 $612 $1,530
ALUM PORCH NO FLOOR 1989 240 $449 $960
NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem
tax purposes.
If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value.
http://www. scpafl.org/pls/web/re_web. seminole_county_title?parcel=0620315050E000110... 3/9/2005
PROJECT SUMMARY
Entire House
DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105
109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665
For: TEDESCORES
Notes:
Weather: Orlando AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 38 OF Outside db 93 OF
Inside db 70 OF Inside db 76 OF
Design TD 32 OF Design TD 17 F
Daily range M
Relative humidity 50
Moisture difference 41 gr/lb
Heating Summary
Building heat loss 22903 Btuh
Ventilation air 0 cfm
Ventilation air loss 0 Btuh
Design heat load 22903 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Heating Cooling
Area (ft) 799 799
Volume (ft') 6390 6390
Air changes/hour 1.20 0.50
Equiv. AVF (cfm) 128 53
Heating Equipment Summary
Make TRANE
Trade
Model
Efficiency
Heating Input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
7.8 HSPF
0 Btuh @ 470F
0 OF
800 cfm
0.035 cfm/Btuh
0.38 in H2O
Sensible Cooling Equipment Load Sizing
Structure 18302 Btuh
Ventilation 468 Btuh
Design temperature swing 3.0 OF
Use mfg. data n
Rate/swing multiplier 0.98
Total sens. equip. load 18395 Btuh
Latent Cooling Equipment Load Sizing
Internal gains 690 Btuh
Ventilation 701 Btuh
Infiltration 1493 Btuh
Total latent equip. load 2884 Btuh
Total equipment load 21278 Btuh
Req. total capacity at 0.80 SHR 1.9 ton
Cooling Equipment Summary
Make TRANE
Trade
Cond
Coil
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
12 EER
19200 Btuh
4800 Btuh
24000 Btuh
800 cfm
0.044 cfm/Btuh
0.38 in H2O
87 %
wrjg htsoft Right -Suite Residential 5.5.17 RSR26017 2005•Mar-10 08:08:51
ACGK E:\Files\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1
RIGHT-J CALCULATION PROCEDURES A, B, C, D
0 Entire House
DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105
109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.20 ach x 6390 ft3 x 0.0167 = 128 cfm
2. Winter infiltration load
1.1 x 128 cfm x 32 OF Winter TD = 4498 Btuh
3. Winter infiltration HTM
4498 Btuh / 209 ft2 Total window = 21.5 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.50 ach x 6390 ft3 x 0.0167 = 53 cfm
2. Summer infiltration load
1.1 x 53 cfm x 17 OF Summer TD = 996 Btuh
3. Summer infiltration HTM
996 Btuh / 209 ft2 Total window = 4.8 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x 41 gr/lb moist.diff. x 53 cfm = 1493 Btuh
Procedure v - Equipment sizing Loaas
1. Sensible sizing load
Sensible ventilation load
1.1 x 25 cfm vent. x 17 OF Summer TD = 468 Btuh
Sensible load for structure (Line 19) + 18302 Btuh
Sum of ventilation and structure loads = 18770 Btuh
Rating and temperature swing multiplier x 0.98
Equipment sizing load - sensible = 18395 Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 25 cfm vent. x 41 gr/lb moist.diff. = 701 Btuh
Internal loads = 230 Btuh x 3 people + 690 Btuh
Infiltration load from Procedure C + 1493 Btuh
Equipment sizing load - latent = 2884 Btuh
Construction Quality is: a No. of Fireplaces is: 0
Bold/Italic values have been manually ovenldden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnghtsoft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-1008:08:51
AM E:\Files\RETA1LPLANS\TEDESCORES\TEDESCORES.rsr Page 1
RIGHT-J WORKSHEET0EntireHouse
DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 3/9/05
109 COMMERCE STREET. LAKE MARY. FL 32746-6206 Phone: (407) 831-2665
J: 7th Ed.
1 Name of room Entire House BED 2 MSTR BED BATHj4MANUAL2Lengthofexposedwall129.5 ft 24.0 ft 25.0 ft 5.0 ft
3 Room dimensions 13.0 x 11.0 ft 14.0 x 11.0 ft 5.0 x 6.0 ft
Ceiings Condit. Option 8.0 ftl heat/cool d 6.0 ft heat/cool 8.0 ft heat/cool 8.0 Ill heat/cool
TYPE OF CST HTM Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) Area Load (Btuh)
EXPOSURE NO. Htg I Clg ft2 Htg Clg ft) Htg Clg Htg Clg ft) Htg Clg
5 Gross a 14B 4.6 1.9 1036 192 200 40
Exposed b 13C 0.0 1.1 0 0 0
walls and c 12C 2.9 1.9 0 0 0 0
partitions d 0.0 0.0 0 0 0 0
e 0.0 0.0 0 0 0 0
f 0.0 0.0 0 0 0 0
6 Windows and a 1C 37.0 128 4737 24 887 29 1056 4 148
glass doors b 8C 37.0 41 1515 0 0 0 0 0 0
Heating c 9C 38.7 40 1549 0 0 0 0 0 0
d IC 37.0 0 0 0 0 0 0 0 0
e 0.0 0 0 0 0 0 0 0 0
f 0.0 01 0 0 0 0 0 0 0
7 Windows and North 19.6 42 817 10 188 10 187 0 0
glass doors NE/NW 0.0 0 0 0 0 0 0 0 0
Cooling E/W 53.6 160 8597 14 772 19 1018 4 214
SE/SW 0.0 0 0 0 0 0 0 0 0
South 29.6 7 209 0 0 0'«• 0 0'«' 0
Horz 0.0 0 0 0'«. 0 0'«• 0 0'«' 0
8 Other doors a 11A 18.9 12.2 0 0 0 0 0 0 0 0 0 0 0 0
b 10D 14.7 9.5 0 0 0 0 0 0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 14B 4.6 1.9 827 3810 1584 168 T74 322 171 790 328 36 166 69
exposed b 13C 0.0 1.1 0 0 0 0 0 0 0 0 0 0 0 0
walls and c 12C 2.9 1.9 0 0 0 0 0 0 0 0 0 0 0 0
partitions d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
10 Ceilings a 16D 1.7 2.2 799 1355 1736 143 243 311 154 261 335 30 51 65
b 16C 2.8 3.4 0 0 0 0 0 0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
11 Floors a 22A 25.9 0.0 130 3357 0 24 622 0 25 648 0 5 130 0
Note: room b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
perimeter c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
is displ. d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
for slab a 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
floors) f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
12 Infiltration a 21.51 4.8 209 44981 996 24 516 114 29 614 136 4 86 19
13 Subtotal loss=6+8..+11+12 20821 3042 3369 580
Less external heating 0 0 0 0
Less transfer 0 0 0 0
Heating redistribution 0 0 0 0
14 Duct loss 10°/ 2082 10°/ 304 10°/ 337 10"/ 58
15 Total loss = 13+14 1 22903 I ••.. 3346 3706 638
16 Int. gains: People @ 300 3 900 0 0 1 300 0 0
Appl. @ 1200 2 1800 0 0 0 0 0 0
17 Subtot RSH gain=7+8..+12+16 16639 1707 2305 368
Less external cooling 0 0 0 0
Less transfer 0 0 0 0
Cooling redistribution 0 0 0 0
18 Duct gain 10"/ 1664 101 171 10°/ 230 100/ 37
19 Total RSH gain=(17+18)'PLF 1.00 18302 1.00 1877 1.00 2535 1.00 40 4
20 Air required (cfm) 800 800 117 82 129 111 22 18
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wr-sghtsOft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-10 08:08:51
AM E:\File$\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1
RIGHT-J WORKSHEET0EntireHouse
DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 3/9/05
109 COMMERCE STREET, LAKE MARY, FL 32746.6206 Phone: (407) 831-2665
J: 7th to.
1 Name of room LIVING UTIL KIT CLOSET14MANUAL2Lengthofexposedwall26.0 ft 28.0 ft 18.0 ft 3.5 ft
3 Room dimensions 17.0 x 13.0 ft 6.0 x 16.7 ft 18.0 x 7.0 ft 3.5 x 7.0 ft
Ceiings Condit. Option 8.0 ft 1 heaVcool 8.0 ft heat/cool 8.0 R heal/cool 8.0 f1l heaVcool
TYPE OF CS HTM Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) Area Load (Btuh)
EXPOSURE NOIHtg Clg ft!) Hig Clg ft) Htg I Clg 112) Htg I Clg ft!) Htg Clg
5 Gross a 14B 4.6 1.9 208 224 144 28
Exposed b 13C 0.0 1.1 0 0 0 0
walls and c 12C 2.9 1.9 0 0 0 0
partitions d 0.0 0.0 0 0 0 0
e 0.0 0.0 0 0 0 0
6 Windows and a 1 C 37.0 62 2292 10 355 0 0 0 0
glass doors b 8C 37.0 0 0 0 0 41 1515 0 0
Heating c 9C 38.7 20 774 0 0 20 774 0 0
d IC 37.0 0 0 0 0 0 0 0 0
e 0.0 0 0 0 0 0 0 0 0
If I 1 0.0 0 0 1 0 01 0 0 0 0
7 Windows and North 19.6 13 254 10 188 0 0 0 0
glass doors NE/NW 0.0 0 0 0 0 0'"• 0 0 0
Cooling E/W 53.6 62 3323 0 0 61 3270 0 0
SE/SW 0.0 0 0 0 0 0 0 0 0
South 29.6 7 209 0 0 0 0 0 0
Horz 0.0 0 0 0 0 0 0 0 0
8 Other doors a 11A 18.9 12.2 0 0 0 0 0 0 0 0 0 0 0 0
b 101) 14.7 9.5 0 0 0 0 0 0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
9 Net a 14B 4.6 1.9 126 581 241 214 988 411 83 382 159 28 129 54
exposed b 13C 0.0 1.1 0 0 0 0 0 0 0 0 0 0 0 0
walls and c 12C 2.9 1.9 0 0 0 0 0 0 0 0 0 0 0 0
partitions d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
10 Ceilings a 16D 1.7 2.2 221 375 480 100 170 218 126 214 274 25 42 53.
b 16C 2.8 3.4 0 0 0 0 0 0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
11 Floors a 22A 25.9 0.0 26 674 0 28 726 0 18 467 0 4 91 0
Note: room b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
perimeter c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
is displ. d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
for slab a 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
floors) f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0
12 Infiltration a i 21.5 4.8 82 1764 3901 10 206 46 61 1312 2901 01 0 0
13 Subtotal loss=6+8..+11+12 6459 2445 4664 261
Less external heating 0 0 0 0
Less transfer 0 0 0 0
Heating redistribution 0 0 0 0
14 Duct loss 10°/ 646 10°/ 244 10°/ 466 10°/ 26
15 Total loss = 13+14 7105 2689 5131 287
16 Int. gains: People (dj 300 2 600 0 0 0 0 0 0
Appl. @ 1200 0 0 1 600 1 1200 0 0
17 Subtot RSH gain=7+8..+12+16 5498 1462 5193 107
Less external cooling 0 0 0 0
Less transfer 0 0 0 0
Cooling redistribution 0 0 0 0
18 Duct gain 10°/ 550 10° 146 109 519 10°/ 11
19 Total RSH gain=(17+18)•PLF 1.00 6047 1.00 1608 1.00 5712 1.00 118
201. Air required (cfm) 248 264 94 70 179 250 10 5
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrvghtsoft Right -Suite Residential 5.5.17 RSR26017 2005•Mar-10 05:05:51
AM E:NFilesNRETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 2
RIGHT-J WINDOW DATA
DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105
109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665
W S D W G L S S O N A S O O W C W S
N K I A L O T H V G N H V V H H N H
D Y R L A W R A H L G C R R G T A A
W L Z E M D G Z L O X Y T M R R
BED 2
a n n a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 19.6 9.6 0.0
a n e a c n 0 d 1 1 90 1.0 1.0 1.0 3.2 53.6 14.4 0.0
MSTR BED
a n w a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 53.6 19.0 0.0
a n n a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 19.6 9.6 0.0
BATH
a n w a c n 0 d 1 1 90 1.0 1.0 1.0 2.0 53.6 4.0 0.0
LIVING
a n w a c n 0 d 1 1 90 1.0 1.0 1.0 5.1 53.6 62.0 0.0
c n S a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 29.6 20.0 12.9
UTIL
a n S a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 29.6 9.6 9.6
KIT
b n e a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 53.6 41.0 0.0
c n e a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 53.6 20.0 0.0
CLOSET
y
wnghtsoft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-1008:08:51
iV11 E:\Files\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1
FORM 60OA-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: TEDESCORES Builder: TEDESCORES
Address: a` w _ -/_ Permitting Office:
City, State: Permit Number:
Owner: g a-v_ Jurisdiction Number -
Climate Zone: ' Central Oq 1'rab
1. New construction or existing New _
2. Single family or multi -family Single family _
3. Number of units, if multi -family 1 _
4. Number of Bedrooms 2 _
5. Is this a worst case? No _
6. Conditioned floor area (ftz) 799 ftz
7. Glass area & type Single Pane Double Pane
a. Clear glass, default U-factor 169.2 ftz 0.0 ftz
b. Default tint 0.0 ftz 0.0 ftz _
c. Labeled U or SHGC 0.0 ftz 0.0 ftz
8. Floor types
a. Slab -On -Grade Edge Insulation R=0.0, 129.5(p) ft _
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior R=5.0, 826.8 ftz _
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic R=19.0, 798.7 ftz _
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 1.0 fit _
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.21 Total as -built points: 12853 PASSTotalbasepoints: 13029
I hereby certify that the plans and specificati covered
01
by this calculation are in com nc&vwotne rida
Energy Code.
PREPARED BY:
DATE: -111016
I hereby certify that this building, as designed, is in
compliance with the Florida Energy Code.
OWNER/AGENT:
DATE:
EnergyGauge® (Vers
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
Cap: 24.0 kBtu/hr _
SEER:13.00
Cap: 24.0 kBtu/hr _
HSPF: 8.20
Cap: 50.0 gallons _
EF: 0.88
WE
PT, _
BUILDING OFFICIAL:
DATE: PANS HUIF' EL
on: FLRCSB v3.30) CITY UF SANFORI.''
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILT
GLASS TYPES
18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points
18 799.0 25.78 3707.7 Single, Clear N 1.0 4.1 9.6 30.19 0.94 273.2
Single, Clear E 1.0 4.2 14.4 63.97 0.92 851.7
Single, Clear W 1.0 4.1 19.0 57.68 0.92 1007.7
Single, Clear N 1.0 4.1 9.6 30.19 0.94 273.2'
Single, Clear W 1.0 3.0 4.0 57.68 0.85 197.0
Single, Clear W 1.0 6.1 62.0 57.68 0.97 3474.4
Single, Clear S 1.0 4.1 9.6 48.22 0.87 404.8
Single, Clear E 1.0 7.8 41.0 63.97 0.99 2594.2
As -Built Total: 169.2 9076.1
WALL TYPES Area X BSPM Points Type R-Value Area X SPM = Points
Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 826.8 1.00 826.8
Exterior 826.8 1.90 1570.9
Base Total: 826.8 1570.9 As -Built Total: 826.8 826.8
DOOR TYPES Area X BSPM Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.20 144.0
Exterior 40.0 4.80 192.0 Exterior Wood 20.0 7.20 144.0
Base Total: 40.0 192.0 As -Built Total: 40.0 288.0
CEILING TYPES Area X BSPM Points Type R-Value Area X SPM X SCM = Points
Under Attic 798.7 2.13 1701.2 Under Attic 19.0 798.7 2.82 X 1.00 2252.3
Base Total: 798.7 1701.2 As -Built Total: 798.7 2252.3
FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM = Points
Slab 129.5(p) 31.8 4118.1 Slab -On -Grade Edge Insulation 0.0 129.5(p -31.90 4131.0
Raised 0.0 0.00 0.0
Base Total: 4118.1 As -Built Total: 129.5 4131.0
INFILTRATION Area X BSPM Points Area X SPM = Points
799.0 14.31 11433.7 799.0 14.31 11433.7
EnergyGauge® DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCSB v3.30
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILT
Summer Base Points: 14487.4 Summer As -Built Points: 19745.8
Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
DM x DSM x AHU)
19745.8 1.000 1.087 x 1.150 x 0.85) 0.262 0.950 5259.0
14487.4 0.4266 6180.3 19745.8 1.00 1.069 0.262 0.950 5259.0
EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILTFGLASSPESditionedXBWPM = Points Overhang
oor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point
18 799.0 5.86 842.8 Single, Clear N 1.0 4.1 9.6 15.07 1.00 144.2
Single, Clear E 1.0 4.2 14.4 12.37 1.02 181.1
Single, Clear W 1.0 4.1 19.0 13.25 1.01 254.3
Single, Clear N 1.0 4.1 9.6 15.07 1.00 144.2
Single, Clear W 1.0 3.0 4.0 13.25 1.02 54.1
Single, Clear W 1.0 6.1 62.0 13.25 1.00 823.1
Single, Clear S 1.0 4.1 9.6 9.90 1.05 99.5
Single, Clear E 1.0 7.8 41.0 12.37 1.01 509.9
As -Built Total: 169.2 2210.4
WALL TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 826.8 2.90 2397.7
Exterior 826.8 2.00 1653.6
Base Total: 826.8 1653.6 As -Built Total: 826.8 2397.7
DOOR TYPES Area X BWPM Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.60 152.0
Exterior 40.0 5.10 204.0 Exterior Wood 20.0 7.60 152.0
Base Total: 40.0 204.0 As -Built Total: 40.0 304.0
CEILING TYPES Area X BWPM Points Type R-Value Area X WPM X WCM = Points
Under Attic 798.7 0.64 511.2 Under Attic 19.0 798.7 0.87 X 1.00 694.9
Base Total: 798.7 511.2 As -Built Total: 798.7 694.9
FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Slab 129.5(p) 1.9 246.1 Slab -On -Grade Edge Insulation 0.0 129.5(p 2.50 323.8
Raised 0.0 0.00 0.0
Base Total: 246.1 As -Built Total: 129.5 323.8
INFILTRATION Area X BWPM Points Area X WPM = Points
799.0 0.28 223.7 799.0 -0.28 223.7
EnergyGauge® DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCSB v3.30
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:, , , PERMIT #:
BASE AS -BUILT
Winter Base Points: 2741.8 Winter As -Built Points: 5707.0
Total Winter X System = Heating Total X Cap X Duct X System X Credit Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
DM x DSM x AHU)
5707.0 1.000 1.078 x 1.160 x 0.87) 0.416 0.950 2466.3
2741.8 0.6274 1720.2 5707.0 1.00 1.093 0.416 0.950 2466.3
EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30
FORM 60OA-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS:... PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2564.00 5128.0 50.0 0.88 2 1.00 2564.00 1.00 5128.0
As -Built Total: 5128.0
CODE COMPLIANCE STATUS
BASE AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
Total
Points
Cooling
Points
Heating + Hot Water = Total
Points Points Points
6180 1720 5128 13029 1 5259 2466 5128 12853
PASS EnergyGaugeTm
DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
FORM 60OA-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , . , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences.
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG,
Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 83.8
The higher the score, the more efficient the home.
1. New construction or existing
2. Single family or multi -family
3. Number of units, if multi -family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (flz)
7. Glass area & type Single Pane
a. Clear - single pane 169.2 flz
b. Clear - double pane 0.0 ftz
c. Tint/other SHGC - single pane 0.0 flz
d. Tint/other SHGC - double pane
8. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH(Seal ed): Interior
b. N/A
New _ 12. Cooling systems
Single family _ a. Central Unit
1 _
2 _ b. N/A
No _
799 flz c. N/A
Double Pane _
0.0 flz _ 13. Heating systems
0.0 flz _ a. Electric Heat Pump
0.0 ftz _
b. N/A
R=0.0, 129.5(p) ft _ c. N/A
14. Hot water systems
a. Electric Resistance
R=5.0, 826.8 ft" _
b. N/A
c. Conservation credits
HR-Heat recovery, Solar
DHP-Dedicated heat pump)
R=19.0, 798.7 flz _ 15. HVAC credits
CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
Sup, R=6.0, 1.0 ft _ MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Cap: 24.0 kBtu/hr _
SEER:13.00 _
Cap: 24.0 kBtu/hr _
HSPF: 8.20
Cap: 50.0 gallons _
EF: 0.88
PT, _
NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPA/DOE EnergyStarT designation),
your home may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu jor
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGaugeO (Version: FLRCSB v3.30)