Loading...
HomeMy WebLinkAbout221 Woodmere Blvd (3)Permit # :UJ Job Address: I " Description of Work: Historic District: r CITY OF SANFORD PERMIT APPLICATION Date: "L ` 05 Kd A:Q- §!A VND d Zoning: Value of Work: S_ IL Permit Type: Building Electrical Mechanic Plumbing Fire Sprinkler/Alarm Pool fi Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechani : Residenti Non -Residential Replacement ew (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair- Residential or Commercial ` Occupancy T esidentia Commercial Industrial Total Square Footage: 1-4(0(0 Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: "(o - 20 - 3 t . 0E Q0 c m 1 c) (Attach Proof of Ownership & Legal Description) Owners Name&Address: CTQA4 ,0-0 t(Y16 R'2 1e Contractor Name & Address: -A-P 1. 9 9A Tt ne;R Fax: ,( O-7) r % C tac a on: [r Phone` 19 Bonding Company: N[1k Address: - - MAD M0 1 Mortgage Lender: Address: Architect/Engineer: U•Phone: r • Address: ! Fax:.: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws: regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR.I'l+.YfNG TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. f NOTI :In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may din the ublic records of this county, and there may be additional permits required from other governmental entities such as water management dis to ag s or federal agnrr:irs. Acceptance of permit is verification that 1 uill notify the owner of the property of the requirements of Florid ' n U S Signature of Owner/Agent Date Sit ; ure of Contractor/Agen Date ItB_ERT G. SO, Print Owner/Agent's Name Print ontracior/Agent's Name AAA A& Signature of Notary -State of Florida Date Signature of Notary -State of F da Date Owner/Agent is _ Personal].- Known to Me or Contractor/Agent i Personally Known to Me or Produced ID Products ID APPLICAI ION APPRO\-ED BY: BldI 6 d / Zoning: L;:::rie5: I-D: initial & Date) (Initial & Date) (Initial & Date) (Initial & Date) Special Conditions: 2 5 3 roo .ra-eu'L E3 MY COMMISSION # DO 212893 EXPIRES: June 14, 21X17 Mod Thro Notary PUCNt UrWrn riten i I 6Fx „b5 aX f' 176 1 IjEo az x wm 7 X- C.V m lu nq W,i 14' rl' Ix-1w J I. ha .2-7idezo me 7 S X38 SUS'2 O/C j\ 2 rICwlen LnL P-1 I ezowr ffmcg—o'-'140 wo 01Rza (2# y i) f GO CJ 35 L w.nLcR 26a A HEATING Alf a o. Boxx CUSTOMER 1CB ADDRESS PIAN No. DRAhN BY APPROVED BY j VOLTAGE DATE 3 D NQs. Maltc• Permit. Number-------------------- Parcel Identilicatlon Number M•,o 05 • Cp, pt p Prepared by: THIS IN Igo11 lRONgIIIIIIl.goo1O111consul a UMPREPARnNAMEu r1 1 ` MARYANNE NMI CLERK OF CIRCUIT COURT DQ - V 2._. SENINOLE COUNTY Rgturn to: ' PK 05643 P6 1624 DEL -AIR HEATING & AIR COND. CLERK' S #1 2065640536 109 COMMERCE STREET, SUITE 1101 RF.8AS 89t48>144 AN REMRDED tRDINB. FFEES PEES 1111.40. LAICEMARY, FLORIDA 32746 RECORDED BY. L NcKinley NO`I`ICC. OF C0imvirz GEiVIENT State' of County o o e The undersigned hereby gives notice that improvements) will be made to certain real property, and in accordan with Chapter 713, Florida Statutes, the following iriformation is provided in this Notice of Commencement. 1. Description of property (Legal description bf the property, and street address if available) ener Nk- v tol21; 2.. General descripti` on1 of.lmprovement(s) 3. Owner Informatlo Name Q gSLo c•>,1So n V1J1'C-ei2.vLQ. ' Address oD a ` Fax Number Telephone NumberQA 3' 1) 3.23 38G7 rn--e S; D ed. 32-f 73 Interest in Property: 4• : Fee SimpleTitleHolder (if other than owner shown above) Name Address WATelephone Number Fax Number 5• . Contra cio ID EL -AIR HEATING & AIR COND. Name 109 COMMERCE STREET, SUITE 1101 Address Telephone Number (-40-1) LAKE MARY, FLORIDA32746FaxNumberSuretY.(i f any) Name y ' CERTIFIED COPY Address Telephone NumberFaxNumberMARYANNE MORSE Amount of bond $ CLERK OF CIRCUIT COURT 7• Y.Lender ( if.any) _ LORIDA Name. Address Telephone Number EP ER Fax Number MAR. 4 0 ZOOS 8. Persons withinthe State of Florida designated by Owner upon whom notices or other d served as providedby §713.13(1)(a)7., Florida Statutes. ocuments may be Name. Address TelephoneNumber Fax Number 9•: in addition to himself or herself, Ow Provided in §713. 13(I)(ner des 9nales the following to receive a COPY 's Notic b), Florida. Statutes, opy othe Lienore . Name 1 f . Address / Telephone Number K Fax Number 10. k' xpiratlon date of rJOilce of commencement (the expiration dale is one year from th unless a different date isspecified) a date of recordirn O Y O L en.>` l C' S Ca Date Signed Sign ture of Owner No e: per §713.13(1)(g), !'owner must sign ...and no orherstead." one else may be permitted to sign ii Sworn. nd. sub who is. ' P as identification. . 20JD5— by Signature of to appear below) Form Revised: 12100 for 19_ to 20 moo • 1 t; MIRINDA C. TURNER . 14 MY COMMISSION # DO 212893 EXPIRES: June 14 2007 Bonded Thru No" Public Underwriters Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 F +r » r 4 JCHr4SON. CFA. A SA f r0& S PROPERTY APPRAISER 11 rr 9[MIIVOLECOUNTYFL nT a< 1 101 E. FIRST ST SANFOR0,FL32771 1468 407-665-7506 Yr• 1 l 1 y, C"' GALE Pl 2005 WORKING VALUE SUMMARY GENERAL Value Method: Market 06-20-31-505-OEOO Number of Buildings: 1 Parcel Id: 0110 Tax District: S1-SANFORD Depreciated Bldg Value: $42,036 Owner: JOHNSON Exemptions: 00- Depreciated EXFT Value: $1,061 MARCELENE HOMESTEAD Land Value (Market): $10,680 Address: 221 WOODMERE BLVD Land Value Ag: $0 City,State,ZipCode: SANFORD FL 32773 Just/Market Value: $53,777 Property Address: 221 WOODMERE BLVD SANFORD 32773 Assessed Value (SOH): $38,741 Subdivision Name: WOODMERE PARK 2ND REPLAT Exempt Value: $25,000 Dor: 01-SINGLE FAMILY Taxable Value: $13,741 Tax Estimator 2004 VALUE SUMMARY SALES Tax Amount(without SOH): $510 Deed Date Book Page Amount Vac/Imp 2004 Tax Bill Amount: $259 WARRANTY DEED 04/1981 01340 1383 $8,400 Improved Save Our Homes (SOH) Savings: $251 2004 Taxable Value: $12,613 Find Comparable Sales within this Subdivision DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS LAND Land Unit Land LEGAL DESCRIPTION PLAT Land Assess Method Frontage Depth Units Price Value LEG LOT 11 BLK E WOODMERE PARK 2ND FRONT FOOT & 60 114 000 200.00 $10,680 REPLAT PB 13 PG 73 DEPTH BUILDING INFORMATION Bid Num Bid Type Year Bit Fixtures Base SF Gross SF Heated SF Ext Wall Bid Value Est. Cost New 1 SINGLE FAMILY 1961 3 858 1,266 858 CONC BLOCK $42,036 $55,311 Appendage / Sgft OPEN PORCH FINISHED / 56 Appendage / Sgft CARPORT UNFINISHED / 220 Appendage / Sgft ENCLOSED PORCH UNFINISHED / 102 Appendage / Sgft OPEN PORCH UNFINISHED / 30 EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New ALUM SCREEN PORCH W/CONC FL 1979 180 $612 $1,530 ALUM PORCH NO FLOOR 1989 240 $449 $960 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www. scpafl.org/pls/web/re_web. seminole_county_title?parcel=0620315050E000110... 3/9/2005 PROJECT SUMMARY Entire House DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105 109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665 For: TEDESCORES Notes: Weather: Orlando AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 OF Outside db 93 OF Inside db 70 OF Inside db 76 OF Design TD 32 OF Design TD 17 F Daily range M Relative humidity 50 Moisture difference 41 gr/lb Heating Summary Building heat loss 22903 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 22903 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft) 799 799 Volume (ft') 6390 6390 Air changes/hour 1.20 0.50 Equiv. AVF (cfm) 128 53 Heating Equipment Summary Make TRANE Trade Model Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.8 HSPF 0 Btuh @ 470F 0 OF 800 cfm 0.035 cfm/Btuh 0.38 in H2O Sensible Cooling Equipment Load Sizing Structure 18302 Btuh Ventilation 468 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.98 Total sens. equip. load 18395 Btuh Latent Cooling Equipment Load Sizing Internal gains 690 Btuh Ventilation 701 Btuh Infiltration 1493 Btuh Total latent equip. load 2884 Btuh Total equipment load 21278 Btuh Req. total capacity at 0.80 SHR 1.9 ton Cooling Equipment Summary Make TRANE Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 7th Ed. 12 EER 19200 Btuh 4800 Btuh 24000 Btuh 800 cfm 0.044 cfm/Btuh 0.38 in H2O 87 % wrjg htsoft Right -Suite Residential 5.5.17 RSR26017 2005•Mar-10 08:08:51 ACGK E:\Files\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1 RIGHT-J CALCULATION PROCEDURES A, B, C, D 0 Entire House DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105 109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.20 ach x 6390 ft3 x 0.0167 = 128 cfm 2. Winter infiltration load 1.1 x 128 cfm x 32 OF Winter TD = 4498 Btuh 3. Winter infiltration HTM 4498 Btuh / 209 ft2 Total window = 21.5 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.50 ach x 6390 ft3 x 0.0167 = 53 cfm 2. Summer infiltration load 1.1 x 53 cfm x 17 OF Summer TD = 996 Btuh 3. Summer infiltration HTM 996 Btuh / 209 ft2 Total window = 4.8 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x 41 gr/lb moist.diff. x 53 cfm = 1493 Btuh Procedure v - Equipment sizing Loaas 1. Sensible sizing load Sensible ventilation load 1.1 x 25 cfm vent. x 17 OF Summer TD = 468 Btuh Sensible load for structure (Line 19) + 18302 Btuh Sum of ventilation and structure loads = 18770 Btuh Rating and temperature swing multiplier x 0.98 Equipment sizing load - sensible = 18395 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 25 cfm vent. x 41 gr/lb moist.diff. = 701 Btuh Internal loads = 230 Btuh x 3 people + 690 Btuh Infiltration load from Procedure C + 1493 Btuh Equipment sizing load - latent = 2884 Btuh Construction Quality is: a No. of Fireplaces is: 0 Bold/Italic values have been manually ovenldden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnghtsoft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-1008:08:51 AM E:\Files\RETA1LPLANS\TEDESCORES\TEDESCORES.rsr Page 1 RIGHT-J WORKSHEET0EntireHouse DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 3/9/05 109 COMMERCE STREET. LAKE MARY. FL 32746-6206 Phone: (407) 831-2665 J: 7th Ed. 1 Name of room Entire House BED 2 MSTR BED BATHj4MANUAL2Lengthofexposedwall129.5 ft 24.0 ft 25.0 ft 5.0 ft 3 Room dimensions 13.0 x 11.0 ft 14.0 x 11.0 ft 5.0 x 6.0 ft Ceiings Condit. Option 8.0 ftl heat/cool d 6.0 ft heat/cool 8.0 ft heat/cool 8.0 Ill heat/cool TYPE OF CST HTM Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) EXPOSURE NO. Htg I Clg ft2 Htg Clg ft) Htg Clg Htg Clg ft) Htg Clg 5 Gross a 14B 4.6 1.9 1036 192 200 40 Exposed b 13C 0.0 1.1 0 0 0 walls and c 12C 2.9 1.9 0 0 0 0 partitions d 0.0 0.0 0 0 0 0 e 0.0 0.0 0 0 0 0 f 0.0 0.0 0 0 0 0 6 Windows and a 1C 37.0 128 4737 24 887 29 1056 4 148 glass doors b 8C 37.0 41 1515 0 0 0 0 0 0 Heating c 9C 38.7 40 1549 0 0 0 0 0 0 d IC 37.0 0 0 0 0 0 0 0 0 e 0.0 0 0 0 0 0 0 0 0 f 0.0 01 0 0 0 0 0 0 0 7 Windows and North 19.6 42 817 10 188 10 187 0 0 glass doors NE/NW 0.0 0 0 0 0 0 0 0 0 Cooling E/W 53.6 160 8597 14 772 19 1018 4 214 SE/SW 0.0 0 0 0 0 0 0 0 0 South 29.6 7 209 0 0 0'«• 0 0'«' 0 Horz 0.0 0 0 0'«. 0 0'«• 0 0'«' 0 8 Other doors a 11A 18.9 12.2 0 0 0 0 0 0 0 0 0 0 0 0 b 10D 14.7 9.5 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 14B 4.6 1.9 827 3810 1584 168 T74 322 171 790 328 36 166 69 exposed b 13C 0.0 1.1 0 0 0 0 0 0 0 0 0 0 0 0 walls and c 12C 2.9 1.9 0 0 0 0 0 0 0 0 0 0 0 0 partitions d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 10 Ceilings a 16D 1.7 2.2 799 1355 1736 143 243 311 154 261 335 30 51 65 b 16C 2.8 3.4 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 11 Floors a 22A 25.9 0.0 130 3357 0 24 622 0 25 648 0 5 130 0 Note: room b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 is displ. d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 for slab a 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 floors) f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 12 Infiltration a 21.51 4.8 209 44981 996 24 516 114 29 614 136 4 86 19 13 Subtotal loss=6+8..+11+12 20821 3042 3369 580 Less external heating 0 0 0 0 Less transfer 0 0 0 0 Heating redistribution 0 0 0 0 14 Duct loss 10°/ 2082 10°/ 304 10°/ 337 10"/ 58 15 Total loss = 13+14 1 22903 I ••.. 3346 3706 638 16 Int. gains: People @ 300 3 900 0 0 1 300 0 0 Appl. @ 1200 2 1800 0 0 0 0 0 0 17 Subtot RSH gain=7+8..+12+16 16639 1707 2305 368 Less external cooling 0 0 0 0 Less transfer 0 0 0 0 Cooling redistribution 0 0 0 0 18 Duct gain 10"/ 1664 101 171 10°/ 230 100/ 37 19 Total RSH gain=(17+18)'PLF 1.00 18302 1.00 1877 1.00 2535 1.00 40 4 20 Air required (cfm) 800 800 117 82 129 111 22 18 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wr-sghtsOft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-10 08:08:51 AM E:\File$\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1 RIGHT-J WORKSHEET0EntireHouse DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 3/9/05 109 COMMERCE STREET, LAKE MARY, FL 32746.6206 Phone: (407) 831-2665 J: 7th to. 1 Name of room LIVING UTIL KIT CLOSET14MANUAL2Lengthofexposedwall26.0 ft 28.0 ft 18.0 ft 3.5 ft 3 Room dimensions 17.0 x 13.0 ft 6.0 x 16.7 ft 18.0 x 7.0 ft 3.5 x 7.0 ft Ceiings Condit. Option 8.0 ft 1 heaVcool 8.0 ft heat/cool 8.0 R heal/cool 8.0 f1l heaVcool TYPE OF CS HTM Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) Area Load (Btuh) EXPOSURE NOIHtg Clg ft!) Hig Clg ft) Htg I Clg 112) Htg I Clg ft!) Htg Clg 5 Gross a 14B 4.6 1.9 208 224 144 28 Exposed b 13C 0.0 1.1 0 0 0 0 walls and c 12C 2.9 1.9 0 0 0 0 partitions d 0.0 0.0 0 0 0 0 e 0.0 0.0 0 0 0 0 6 Windows and a 1 C 37.0 62 2292 10 355 0 0 0 0 glass doors b 8C 37.0 0 0 0 0 41 1515 0 0 Heating c 9C 38.7 20 774 0 0 20 774 0 0 d IC 37.0 0 0 0 0 0 0 0 0 e 0.0 0 0 0 0 0 0 0 0 If I 1 0.0 0 0 1 0 01 0 0 0 0 7 Windows and North 19.6 13 254 10 188 0 0 0 0 glass doors NE/NW 0.0 0 0 0 0 0'"• 0 0 0 Cooling E/W 53.6 62 3323 0 0 61 3270 0 0 SE/SW 0.0 0 0 0 0 0 0 0 0 South 29.6 7 209 0 0 0 0 0 0 Horz 0.0 0 0 0 0 0 0 0 0 8 Other doors a 11A 18.9 12.2 0 0 0 0 0 0 0 0 0 0 0 0 b 101) 14.7 9.5 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 14B 4.6 1.9 126 581 241 214 988 411 83 382 159 28 129 54 exposed b 13C 0.0 1.1 0 0 0 0 0 0 0 0 0 0 0 0 walls and c 12C 2.9 1.9 0 0 0 0 0 0 0 0 0 0 0 0 partitions d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 10 Ceilings a 16D 1.7 2.2 221 375 480 100 170 218 126 214 274 25 42 53. b 16C 2.8 3.4 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 11 Floors a 22A 25.9 0.0 26 674 0 28 726 0 18 467 0 4 91 0 Note: room b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 perimeter c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 is displ. d 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 for slab a 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 floors) f 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 12 Infiltration a i 21.5 4.8 82 1764 3901 10 206 46 61 1312 2901 01 0 0 13 Subtotal loss=6+8..+11+12 6459 2445 4664 261 Less external heating 0 0 0 0 Less transfer 0 0 0 0 Heating redistribution 0 0 0 0 14 Duct loss 10°/ 646 10°/ 244 10°/ 466 10°/ 26 15 Total loss = 13+14 7105 2689 5131 287 16 Int. gains: People (dj 300 2 600 0 0 0 0 0 0 Appl. @ 1200 0 0 1 600 1 1200 0 0 17 Subtot RSH gain=7+8..+12+16 5498 1462 5193 107 Less external cooling 0 0 0 0 Less transfer 0 0 0 0 Cooling redistribution 0 0 0 0 18 Duct gain 10°/ 550 10° 146 109 519 10°/ 11 19 Total RSH gain=(17+18)•PLF 1.00 6047 1.00 1608 1.00 5712 1.00 118 201. Air required (cfm) 248 264 94 70 179 250 10 5 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrvghtsoft Right -Suite Residential 5.5.17 RSR26017 2005•Mar-10 05:05:51 AM E:NFilesNRETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 2 RIGHT-J WINDOW DATA DEL AIR HEATING,AIR CONDITIONING,R Job: PERRES 319105 109 COMMERCE STREET, LAKE MARY, FL 32746-6206 Phone: (407) 831-2665 W S D W G L S S O N A S O O W C W S N K I A L O T H V G N H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D G Z L O X Y T M R R BED 2 a n n a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 19.6 9.6 0.0 a n e a c n 0 d 1 1 90 1.0 1.0 1.0 3.2 53.6 14.4 0.0 MSTR BED a n w a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 53.6 19.0 0.0 a n n a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 19.6 9.6 0.0 BATH a n w a c n 0 d 1 1 90 1.0 1.0 1.0 2.0 53.6 4.0 0.0 LIVING a n w a c n 0 d 1 1 90 1.0 1.0 1.0 5.1 53.6 62.0 0.0 c n S a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 29.6 20.0 12.9 UTIL a n S a c n 0 d 1 1 90 1.0 1.0 1.0 3.1 29.6 9.6 9.6 KIT b n e a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 53.6 41.0 0.0 c n e a c n 0 d 1 1 90 1.0 1.0 1.0 6.8 53.6 20.0 0.0 CLOSET y wnghtsoft Right -Suite Residential 5.5.17 RSR26017 2005-Mar-1008:08:51 iV11 E:\Files\RETAILPLANS\TEDESCORES\TEDESCORES.rsr Page 1 FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: TEDESCORES Builder: TEDESCORES Address: a` w _ -/_ Permitting Office: City, State: Permit Number: Owner: g a-v_ Jurisdiction Number - Climate Zone: ' Central Oq 1'rab 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 2 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ftz) 799 ftz 7. Glass area & type Single Pane Double Pane a. Clear glass, default U-factor 169.2 ftz 0.0 ftz b. Default tint 0.0 ftz 0.0 ftz _ c. Labeled U or SHGC 0.0 ftz 0.0 ftz 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 129.5(p) ft _ b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior R=5.0, 826.8 ftz _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 798.7 ftz _ b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 1.0 fit _ b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.21 Total as -built points: 12853 PASSTotalbasepoints: 13029 I hereby certify that the plans and specificati covered 01 by this calculation are in com nc&vwotne rida Energy Code. PREPARED BY: DATE: -111016 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: EnergyGauge® (Vers Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. Cap: 24.0 kBtu/hr _ SEER:13.00 Cap: 24.0 kBtu/hr _ HSPF: 8.20 Cap: 50.0 gallons _ EF: 0.88 WE PT, _ BUILDING OFFICIAL: DATE: PANS HUIF' EL on: FLRCSB v3.30) CITY UF SANFORI.'' FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 799.0 25.78 3707.7 Single, Clear N 1.0 4.1 9.6 30.19 0.94 273.2 Single, Clear E 1.0 4.2 14.4 63.97 0.92 851.7 Single, Clear W 1.0 4.1 19.0 57.68 0.92 1007.7 Single, Clear N 1.0 4.1 9.6 30.19 0.94 273.2' Single, Clear W 1.0 3.0 4.0 57.68 0.85 197.0 Single, Clear W 1.0 6.1 62.0 57.68 0.97 3474.4 Single, Clear S 1.0 4.1 9.6 48.22 0.87 404.8 Single, Clear E 1.0 7.8 41.0 63.97 0.99 2594.2 As -Built Total: 169.2 9076.1 WALL TYPES Area X BSPM Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 826.8 1.00 826.8 Exterior 826.8 1.90 1570.9 Base Total: 826.8 1570.9 As -Built Total: 826.8 826.8 DOOR TYPES Area X BSPM Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.20 144.0 Exterior 40.0 4.80 192.0 Exterior Wood 20.0 7.20 144.0 Base Total: 40.0 192.0 As -Built Total: 40.0 288.0 CEILING TYPES Area X BSPM Points Type R-Value Area X SPM X SCM = Points Under Attic 798.7 2.13 1701.2 Under Attic 19.0 798.7 2.82 X 1.00 2252.3 Base Total: 798.7 1701.2 As -Built Total: 798.7 2252.3 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM = Points Slab 129.5(p) 31.8 4118.1 Slab -On -Grade Edge Insulation 0.0 129.5(p -31.90 4131.0 Raised 0.0 0.00 0.0 Base Total: 4118.1 As -Built Total: 129.5 4131.0 INFILTRATION Area X BSPM Points Area X SPM = Points 799.0 14.31 11433.7 799.0 14.31 11433.7 EnergyGauge® DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT Summer Base Points: 14487.4 Summer As -Built Points: 19745.8 Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points DM x DSM x AHU) 19745.8 1.000 1.087 x 1.150 x 0.85) 0.262 0.950 5259.0 14487.4 0.4266 6180.3 19745.8 1.00 1.069 0.262 0.950 5259.0 EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILTFGLASSPESditionedXBWPM = Points Overhang oor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point 18 799.0 5.86 842.8 Single, Clear N 1.0 4.1 9.6 15.07 1.00 144.2 Single, Clear E 1.0 4.2 14.4 12.37 1.02 181.1 Single, Clear W 1.0 4.1 19.0 13.25 1.01 254.3 Single, Clear N 1.0 4.1 9.6 15.07 1.00 144.2 Single, Clear W 1.0 3.0 4.0 13.25 1.02 54.1 Single, Clear W 1.0 6.1 62.0 13.25 1.00 823.1 Single, Clear S 1.0 4.1 9.6 9.90 1.05 99.5 Single, Clear E 1.0 7.8 41.0 12.37 1.01 509.9 As -Built Total: 169.2 2210.4 WALL TYPES Area X BWPM Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 826.8 2.90 2397.7 Exterior 826.8 2.00 1653.6 Base Total: 826.8 1653.6 As -Built Total: 826.8 2397.7 DOOR TYPES Area X BWPM Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.60 152.0 Exterior 40.0 5.10 204.0 Exterior Wood 20.0 7.60 152.0 Base Total: 40.0 204.0 As -Built Total: 40.0 304.0 CEILING TYPES Area X BWPM Points Type R-Value Area X WPM X WCM = Points Under Attic 798.7 0.64 511.2 Under Attic 19.0 798.7 0.87 X 1.00 694.9 Base Total: 798.7 511.2 As -Built Total: 798.7 694.9 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM = Points Slab 129.5(p) 1.9 246.1 Slab -On -Grade Edge Insulation 0.0 129.5(p 2.50 323.8 Raised 0.0 0.00 0.0 Base Total: 246.1 As -Built Total: 129.5 323.8 INFILTRATION Area X BWPM Points Area X WPM = Points 799.0 0.28 223.7 799.0 -0.28 223.7 EnergyGauge® DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, , , PERMIT #: BASE AS -BUILT Winter Base Points: 2741.8 Winter As -Built Points: 5707.0 Total Winter X System = Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points DM x DSM x AHU) 5707.0 1.000 1.078 x 1.160 x 0.87) 0.416 0.950 2466.3 2741.8 0.6274 1720.2 5707.0 1.00 1.093 0.416 0.950 2466.3 EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:... PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2564.00 5128.0 50.0 0.88 2 1.00 2564.00 1.00 5128.0 As -Built Total: 5128.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 6180 1720 5128 13029 1 5259 2466 5128 12853 PASS EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , . , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG, Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 83.8 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (flz) 7. Glass area & type Single Pane a. Clear - single pane 169.2 flz b. Clear - double pane 0.0 ftz c. Tint/other SHGC - single pane 0.0 flz d. Tint/other SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH(Seal ed): Interior b. N/A New _ 12. Cooling systems Single family _ a. Central Unit 1 _ 2 _ b. N/A No _ 799 flz c. N/A Double Pane _ 0.0 flz _ 13. Heating systems 0.0 flz _ a. Electric Heat Pump 0.0 ftz _ b. N/A R=0.0, 129.5(p) ft _ c. N/A 14. Hot water systems a. Electric Resistance R=5.0, 826.8 ft" _ b. N/A c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) R=19.0, 798.7 flz _ 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, Sup, R=6.0, 1.0 ft _ MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 24.0 kBtu/hr _ SEER:13.00 _ Cap: 24.0 kBtu/hr _ HSPF: 8.20 Cap: 50.0 gallons _ EF: 0.88 PT, _ NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPA/DOE EnergyStarT designation), your home may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu jor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGaugeO (Version: FLRCSB v3.30)