HomeMy WebLinkAbout1000 WP Ball Blvd (2)CITE' OF SANFORD FIRE DEPARTMENT
FEES FOR SERVICES
PHONE # 407-302-1091 * FAX #: 407-330-5677
DATE: �_ :'� -� PERMI'I' N:
BUSINESS NAME / PROJECT: 13
ADDRESS: 9( --, ice'; F, /iS �►,ti
PHONE NC�`)� JCS dn FAX NO.: C_ -�-�.
CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION (] PLANS REV1E W�<p
F. A. F.S. [ ] HOOD [ ] PAINT BOOTFI (J BURN13F.MIT [ J
TENT PERMIT f ] TANK PERMIT [ ] OTHER ,r
TOTAL FEES: $ C) (PER UNIT SEE BELOW) �C
COMMENTS:
Address / Bldg. ## / Unit ##
1.
2.
3.
4,
5,
6.
7.
8.
9.
10.
1t.
12.
13.
14.
15.
16,
17,
18.
19.
20.
Square Footage Fees per Bldg. / Unit
Fees must be paid to Sanford Building Department, 300 N. Park Am, Sanford, FL 32771 Phone N -407-
330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take
place. I certify that the above is true and correct and that I
will comply with all applicable codes and ordinances
of the City of Sanford Florida
Sanford Fire Pv r—retee 6YDivision - Applicant's Signature �-
GENERAL • NOTES
1, THE INSTALLING CONTRACTOR MUST PROVIDE THE FIRE `ALARM
CONTRACTOR WITH ACCURATE MARKED UP DRAWINGS SHOWING ALL
JUNCTION BOXES, TERMINAL CABINETS, DEVICE LOCATIONS, CABLE ROUTING,
ETC. FOR THE USE IN MAKING "RECORD DRAWINGS". THE FIRE ALARM
COMPANY WILL REVISE DRAWINGS ACCORDINGLY.
2, CONDUIT ROUTING AND CONDUIT SIZE SHALL BE DETERMINED BY THE
CONTRACTOR, IN C'ONJUNCTIO11 WITH (NEC), AND INDICATED ON THE
RECORD DRAWINGS. CONDUIT FILL SHALL NOT EXCEED 40%.
3. FIRE ALARM WIRII`1G SHALL. BE INSTALLED PER NEC, MANUFACTURERS
INSTf,UCTIONS, AND THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
4. SMOKE DETECTORS SHALL BE MOUNTED IN ACCORDANCE WITH NEPA 72.
DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR --FLOW NOR CLOSER
THAN THREE FEET (3 FT) OF ANY AIR SUPPLY DIFFUSER,
5. ALL. WORK SHALL BE DONE IN ACCORDANCE WITH ADOPTED EDITIONS OF
U.B.C. TITL'S 19, TITLE 24, NFPA, AND AMERICANS WITH DISABILITIES ACT
(ADA) AS REQUIRED BY THE GOVERING AGENCIES,
6. PRIMARY POWER SOURCE (120VAC) TO FACP AND POWER SUPPLIES MUST
BE ON A DEDICATED BRANCH CIRCUIT, FROM THE EMERGENCY GENERATO
(IF APPLICABLE), WITH THE DISCONNECTING MEANS MARKED "FIRE ALARM
CONTROL CIRCUIT". THE LOCATION OF THE DISCONNECT MUST BE.
IDENTIFIED AT THE FACP AND POWER SUPPLIES. ALL FIRE ALARM CIRCUIT
BREAKERS MUST BE CLEARLY MARKED AND MECHANICALLY SECURED TO
PREVENT ANY UNAUTHORIZED TAMPERING.
7, WHEN POWERING UP THE FACP (DR REMOTE POWER SUPPLIES BE SURE TO'
APPLY AC VOLTAGE BEFORE DC VOLTAGE, WHEN POWERIf,IG (DOWN,
REMOVE DC SUPPLY BEFORE AC DISCONNECT,
8, DEVICE POLARITY MUST BE OBSERVED,
9, ALL INITIATIP-IG AND NOTIFICATIOI'�l CIRCUIT WIRIhIG MUST BE SUPERVISED FOR
CIRCUIT INTEGRITY.
10. ALL WIRING, INCLUDING `:SHIELDS, MUST BE DRY AND FREE OF SHORTS AND
GROUNDS.
11, STROBE DEVICES SHALL BE SYNCHRONIZED.
12, AUDIBLE DEVICES SHALL USE SYNCHRONIZED TEMPORAL (CODE 3) TONE.
13, ALL DEVICES SHALL BE OPTIONALLY LABELED WITH THEIR ADDRESS OR
CIRCUIT NUMBER. ALL ADDRESSING SHALL BE NOTED ON THE RECORD
DRAWINGS.
14. PROVIDE WEATHERPROOF NEMA ENCLOSURES TO ALL DEVICES THAT ARE
EXPOSED TO THE ENVIRONMENT.
15, DIFFERENTIAL PRESSURE TESTING FOR DUCT DETECTORS MUST BE
PERFORMED BY THE MECHANICAL CONTRACTOR AFTER AIR HANDLER
SYSTEMS HAVE BEEN BALANCED. A WRITTEN COPY OF THESE TESTS
SHALL BE TURNED OVER TO THE ENGINEER PRIOR TO SYSTEM FINAL.
16, ALL DUCT DETECTORS TO BE INSTALLED PER MANUFACTURER INSTALLATION
INSTRUCTIONS AND ALL APPLICABLE NFPA, UBC AND UMC STANDARDS.
17. ELECTRICAL CONTRACTOR TO PROVIDE ALL CONDUIT AND STANDARD
BACK—BOXES AS REQUIRED TO COMPLETE THE PROJECT.
18, ALL JUNCTION BOXES MUST HAVE RED COVERS AND MARKED "FIRE ALARM" IN
LEGIBLE LETTERING.
19. ALL FIRE ALARM DEVICES MUST BE INSTALLED IN A PROPER BACK BOX.
NO DEVICE SHALL BE INSTALLED WITHOUT A BACK --BOX,
20. PROVIDE PROPER GROUI`'1DING OF FIRE ALARM PANEL AND REMOTE POWER
SUPPLIES BY MEANS OF GROUND ROD, OR COLD WATER C:OPPER PIPE IS
ACCEPTABLE IF WATER METER I' -S STRAPPED,
21, INITIATING DEVICE CIRCUITS (IGC) AND NOTIFICATION APPLIANCE CIRCUITS
(NAC), ARE TWO WIRE CLASS "B". T --TAPPING IS NOT ALLOWED ON ANY
OF THESE CIRCUITS.
22, SIGNALING LINE CIRCUITS (SLC) ARE TWO WIRE DATA COMMUNICATINS
CIRCUITS, T --TAPPING IS ALLOWED ONLY AS INDICATED 01,,1 THE
DRA)HINGS,
BATTERY CALCULATION WORKSHEET
FIRE ALARM CONTROL PANEL NUMBER CURRENT TOTAL
OF, PER DEVICE CURRENT
DEVICE DEVICES ALARM SUPV. ALARM SUPV.
Unirn0de 10 1 0.245 0.065 0,245 0.065
Annunciator
1
0,04 1
0.023
0.'04
0.023
PLIII Stations
4
0
0
0
0
Smoke Detector
1
Q.1
0.0009
0.1
0.0009
Duct Detector
3
0,07
0.0'15
0.21
0.045
Remote 'Test Device
3
0.008
0.012
0,
0.036
VVgter Flow
11
0
0
0
0
Tamper
1
0
0
0
0
Lock Box_
I
0
0
0
0
LED -101M
1
0.Q17
0
0.017
0
Power Super�ii ion Relays
I
0.025
0.025
0.025
0.025
0
N/A
0
0
0,
0
1
0
0
0
0
0
FSA FIFE SYSTEM ANNUNCIATOR ALARM
FIRELITE
0
0
0
0
Q 0
0,
0
��
TOTAL$
� �
0.637
0.1949
A. TOTAL SUPERVISORY' CURRENT
�
�
0.1949
� _ _ E (24 OR 60 HOURS)
B. STANDBY Wf1M
FIRE. LITE P/N 10103
---
� 24
,
C. TOTAL SUPERVISORY CURRENT X STAND BY TIME
4.6776
N/A
—
D. TOTAL ALARM CURRENT
0.637
I. ALARM TIME HOURS (5 MIN = 0.084 HRS)
�IN
—
1
0.084
.�..�..
_.,._.r..._,..,._ _
F, TOTAL ALARM CU RRE INT X ALARM TIME 0.05351
G. RECORED AMPERE HOURS Add line C & F 4.73.111
H. TOTAL REQUIRED AMPERE AFTER A 1.2 DERATING FACTOR 5.67733
INSTALLED BATTERY WILL BE 8 AH
FIRE ALARM DEVICE LEGEND
BATTERY CALCULATION WORKSHEET
PS '#1 NUMBER CURRENT TOTAL
OF PER DEVICE CURRENT
DEVICE DEVICES ALARM SUPV, ALARM SUPV.
QTY PER FLOOR
FIRE ALARM Pk,IEL & DEVICE WIRING DIAGRAMS
SYMBOL DESCRIPTION
MANUFACTURER
MODEL
PART NUMBER
Horn Strobe 75cd 5
BACK -BOX INFORMATION
0
0.835
0
Strobe 75cd 11
0.16
Q
1,76
0
G
2
3
4
Fan Relay `I
1
EOL , END OF LINE DEVICE
1
0
0
0
0
0
Re=RESISTOR
FIRELITE
0
0
10
0
0
0
0
PROVIDED WITH FRCP PANEL
R1=RELAY
SYSTEM SENSOR
PAM2
Q
1
0
0
0
0
0
FACP FIRE ALARM cot,iTROL PANEL
FIRELITE
UNIMODE-10
ADT—UNIMODE-10
1
0
0
0
0
N/A
FCPS REMOTE POWER SUPPLY
FIRELITE
FCPS-24F
0
1
0
0
0
0
N/A
FSA FIFE SYSTEM ANNUNCIATOR ALARM
FIRELITE
ADT--LED-10
ADT—LED-10
1
0
0
0
0URFAGE:
EMI—FLUSH: ;:3—GANG, 2 3/'16" DEEP (MIN) (SEE NOTE' 23) '
A. TOTAL SUPERVISORY CURRENT
0.065
24
B. STANDBY TIME (24 OR 60 HOURS)
FIRE. LITE P/N 10103
FAG FIRE ALARM COMMUNICATOR
FIRELITE
N/A
N/A
—
--'
—
--
—
COMM.UNICATOR INTEGRAL TO PANEL
❑�� PULL STATION
FIRELITE
N/A
BG 12
4
0
0
U
0
H. OTAL REQUIRED AMPERE AFTER A 1.2 DERATING FACTOR
C0 HEAT DETECTOR
BATTERY BACKUP 7 AH
^
R/F=RATE OF RISE/FIXED 13,E
HD— 01
0
0
0
0
0
SURFACE: OCTAGANOL OR 4»X4» X1--1/2'
R/F=RATE OF RISE/FIXED 200
HD—r02
0
0
0
0
0}
SEMI -FLUSH: OCTAGONAL OR DIRECT MOUNT (USE REVERSIBLE MOUI',ITING PLATE INCLUDED
F=FIXED 135
HD—�03
0
0
0
0
0
WITH DETECTOR)
F=FIXED 200
HD -604
0
0
0
0
0
FK_B_1 KNOX BOX (iF REQUIRED)
1
0
0
0
0
C?)�R SMOKE/HEAT DETECTOR
N/A
N/A
0
0
0
0
0
, SMOKE DETECTOR
SURFACE; OCTAGANOL OR 4"X4"X1-1 /2"
— P=PHOTOELECTRIC
2151
N/A
1
0
0
.0
0
SEMI—FLUSH: (DCTAGONAL OR DIRECT MOUNT (USE REVERSIBLE MOUNTING PLATE INCLUDED
1=IONIZATION
SYSTEM SENSOR
1151
N/A
0
0
0
0
0.
WITH DETECTOR)
DUCT SMOKE DETECTOR
INSTALLED BY
OTHERS
N/A
DH100ACDCLP
3
0
0
0
0
SYSTEM SENSOR
V FLOW DETECTOR
BY OTHERS
N/A
N/A
1
0
0
0
0
PRESSURE DETECTOR
BY OTHERS
N/A
N/A
0
0
0
0
0
t� TAMPER DETECTOR
BY OTHERS
N/A
N/A
1
0
0
0
0
77
L"J MINI—HORN
N/A
N/A
N/A
0
0
0
0
0
HORN/Sl•ROBE
<
SYSTEM SENSOR
N/A
P1224MC
5
0
0
0
0
-
`:SEMI—FLIJSH: STANDARD 4"X4"X1-1/2" OR 2"X4*'X1 —7/8" BOXES
l 'JXXc
SURFACE; SEE DETAIL
WP HORN/STROBE
� XXc
N/A
N/A
4P1224MCK
(7
0
0
0"
0
- — - -
SURFACE; USE WBB WEATHERPROOF ^BACK—BOX
,0� ;{ ,c STROBE
SYSTEM SENSOR
N/A
S1.224MC
7
0
0
;Ori
0
SEMI—FLUSH: STANDARD 4"X4"X1-1/2" OR 2"X4"X1-7/8" BOXES
SURFACE: SEE DETAIL
XX�.
C STROBE
SYSTEM SENSOR
N/A
S1224MCK
.4
0
0
'0"
0
SURFACE: USE WBB WEATHERPROOF BACK—BOX
'—]RTS S REMOTE ALARM INDICATING/TEST
SYSTEM SENSOR
N/A
RTS451
3
0
0
0
'0
KHS ANSUL DEVICE
BY OTHERS
N/A
N/A
3
0
0
0
0
CONNECT
FAIN SHUTDOWN RELAX`
R
BY OTHERS
N/A
N/A
1
0
0
0
0
CONNECT
BATTERY CALCULATION WORKSHEET
PS '#1 NUMBER CURRENT TOTAL
OF PER DEVICE CURRENT
DEVICE DEVICES ALARM SUPV, ALARM SUPV.
FCPS . 1 Q,145 0.065 0.145 0.065
FIRE ALARM Pk,IEL & DEVICE WIRING DIAGRAMS
0
0
0
0
Horn Strobe 75cd 5
0,167
0
0.835
0
Strobe 75cd 11
0.16
Q
1,76
0
0
0
0
0
Fan Relay `I
1
0
1
0
0
0
0
0
0
Q
0
0
Q
0
0_
TT
.
0
Q
0
_0
0
0
0
0
0
Q
0
0
0
0
_.
0
0
0
0
0
0
Sync Module 1
0.0'11
0
0.011
0
TOTALS
3.7510.065
A. TOTAL SUPERVISORY CURRENT
0.065
24
B. STANDBY TIME (24 OR 60 HOURS)
C. TOTAL SUPERVISORY CURRENT X STAND BY TIME
1:56
D, TOTAL ALARM CURRENT _-7-7
3.751
E. ALARM TIME IN HOURS (5 MIN = Q.084
im
^0 084
_HRS)
F. TO""I"AL ALARM CURRENT XALARNI TIME I
Q.31508'
1G7
. REQUIRED AMPERE HOURS Add line
C & F 1.87508
H. OTAL REQUIRED AMPERE AFTER A 1.2 DERATING FACTOR
- , 2.2501
BATTERY BACKUP 7 AH
BUILDING INFORMATION
GENERAL DESCRIPTION: SINGLE STORY RESTAURANT
OCCUPANCY TYPE: OCCUPANCY LOAD: 218
11 NEW ❑ EXISTIIN(;
IN ASSEMBLY ❑ DETENTION/CORRECTIONAL
❑ EDUCATIONAL ❑ ONE—TWO FAMILY DWELLING
[]DAY—CARE ❑ LODGING or ROOMING
❑ HEALTH CRE ❑ HOTEL/DORMITORY
❑ AMBULATORY HEALTH CARE ❑ APARTMENT
❑ RESIDENTIAL BOARD & CARE ❑ MERCANTILE
❑ BUSINESS ❑ INDUSTRIAL
SPECIAL STRUCTURE/HIGH--RISE
DOES STRUCTURE HAVE AUTOMATIC 'SPRINKLER S"(STEM?
N 0 ❑ PARTIAL M FULL
R'E�IEV��
five P-trjlv DiveDate,
DRAWING' SCHEDULE
FA -1 ,0
GENERAL FIRE ALARM INFORMATION
FA -1.1
FIRE ALARM LA`(OUT
FA --1.2
FIRE ALARM Pk,IEL & DEVICE WIRING DIAGRAMS
FIRE ALARM DETAILS OPERATION MATRIX
_ Ths design including s •�ifis ,—tfo..rs drawings, � s— J der' n conceP._t_s —'s_t._h.._e _p rvPe tyof Security S �ie nsInc.Inr(ADT), andd is furnisted on a r
anfident'aI basis, wth tha:a• x ress d understanding e st r'�n9kh t it will not be Bald transferred, _ co ied or isodla
the detriment t of 1�T without writtenpar'gslan. The recipient'enk further agrees not to r'r.4Iose the va
nterty to any r
ther. party except for the specific purpose cantrar rd for vith ADT. ADT makes no rapnu^entations as to the operability or accuracy of any systerrrs, subsystems, assemblies, or other information contained herein unless specifically identified for Construction.
I
70
a
a
TO
FAC P TO iN/,AU
FK _HS1 FK -H -Sl lip
FACP I
75c
0
75c
,I
�I75c, 61
This design including specifications, drawings, and design concepts is the property of ADT Security Systems, Inc. (AI and is furnished on a confidential basis, with the expressed
TO FACP
,I IV I r I J
Mount Lock Box
6A.F.F.
0 EOL Z7
K VB
Re
Tl�
FE -0- -L] Z Re 4
75c[T-�
75c
V1' III:! -int -
TO
ki-ILE
VTU_1
(e)
R
that it will not be sold, transferred, copied, or used to the detriment of ADT without written permission. The recipient further agrees not to disclose the contents to any other party except for the
107
a
UN MODE -10 RISER DIAGRAM
PS FACP FSA
Y: EFJ
Z 1
L
Checked By: MDS
L�O Re
DW O File
mo --Li Z 2
Sales
Re
Title:
FE-0—LI Z 3
Re
Scale:
L-] 1--1P
Z 4
ni
11 P FE—O - R e
P
Elp EOL IZ5
Re
I
iF- _�? )-
__1 -
( ? }__ EF4R 07L
IMZR'e
RTU -3 RTU -2
RI
RTU -1 MUA-1
[K::B:i [wo-L7
_iZ
Re
J<HS K �HS KHS
Z'9
EOL
R e
75c 75c
WP C) WP WP WP
75c 7r>c « 75c,'L]Re NAC 1
7 Sc Sc")c
75c 75(-., 75c 75c
75c 75c 75c 75c - 75c IELIRe NAC2
OFFICE WALL ELEVATION
CONDUIT -]
IAC_;CESS _Vtt
WALL
RJ31 PHONE
JACKS (BY
FOCUS OWNER)
CADET
6"
DEDICATED
1 20VAC
FCPS REMOTE
UNIMODE TEST
200PLUS STATIONS
tin
3" THERMOSTATS
1._11"
4'-3" 4'-6"
AFF AFF
00
SAFE
DEDICATED 120VAC REQUIRED
FOR FA SYSTEM PLUG-IN
POWER TRANSFORMER
WIRE TYPE LEGEND
IDC 18/2 FPL/R/P
NAC 14/2 FPL/R/P
FSA 16/4 FPL/R/P
24VDC AUX POWER
14/2 FPL/R/P
RTS (2) 22/4 FPL/'R/P
AUDIO 14/2 FPL/R,/P
contracted for with ADT. ADT makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction.
TRI CON
CONSULTING ENGINEERS
777 S. Harbour Wand BNd, STE 870, TAMPA, FL 33602
813.227.9190 FAX 813 . 227. 9195
Certificate of Authorization No. 00008363
SEAL
DENNIS E. VANN
FL. PE, #57620
SMOKEY BONES
STORE #7632
1000 WP Ball Blvd.
Sanford, Fl
Stamp Area
REVISIONS
No. Date Description
1.0 03/22/05 REVISED FLOOR PLAN
1.5 10/10/05 SUBMITTALS
tycoIre &
tecurity CAEi
ADT Security Services, / 8607 Roberts
Inc. Systems Sales & Dr, Atlanta, Go.
Engineering 30328
678-585-5800
Budding Type
P-5 R
rawn
Y: EFJ
Dote: 03 14/05
Checked By: MDS
Date. 03/14/05
DW O File
Name:
SB SanfordFL BAFA
Sales
Consultant:
Pete Marshah
Title:
Fire Alarm Layout
Scale:
1/411= 1 1
Sheet:
FA -1.1
16/4 AWG --�
SET DIPSWITCH
— 6 TO ON/OPEN
BAAd9 C1_a7 11___
C
(r1
A u
w®a
N
C Cj
®a M
®0
N ®a
4-
W®a
tv —09
00
■ OJ
ADT -LED- 10
REMOTE
ANNUNCIATOR
(DN
C_
INSTALL
120 Ohm
TERMINATING
RESISTOR
W
3
0
a.
0
U
W
R
1%
W
CIO
L
Ld
W
o'
U
c-; l i I o 0 0 o r✓ , d
L
PANEL. INTERCONNECT DETAIL_
12AWG
fl 00 0)
W W W W W W W W W W
SUPPLIED
0 0 0 0 0 0 0 o 0 o BY EC
N N N N N N N N N N
o
+ — +Ln CS
—
M E)E)€ T131
I
[:]AC POWER TROUBLE
ALARM ❑SUPERVISORY
RESET SILENCE MODE
F-1 1 2 P] FFD
]EIE
F]F81 ❑ IE EVENT
O ❑ E ❑ SNORE
UN MODE -10 CONTROLS and INDICATORS
909017090
r_1 AC POWER [TROUBLE
�JALARM ❑SUPERVISORY
RESET SILENCE MODE
F-11 M F 3 1 F F]�
F FE][7
- o a F EVENT
a a FBI Fc I [STORE
FRONT PANEL SWITCHES
RESET
SILENCE
MODE
UP ARROW (ACK)
DOWN ARROW (ACK)
1 st EVENT
ENTER/STORE
DIGITS 0 thru 9
LETTERS A thru F
DISPLAYS
ALARM — RED LED
TROUBLE — YELLOW LED
SUPERVISORY — YELLOW LED
AC POWER — GREEN LED
FOUR, SEVEN SEGMENT DISPLAYS — RED
PRIMARY PHONE LINE ACTIVE — RED LED
SECONDARY PHONE LINE ACTIVE — RED LED
'KISSOFF' SIGNAL FROM CENTRAL STATION — GREEN LED
SILENCE — YELLOW LED
MODEM — GREEN LED
LOCAL SOUNDER
A PIEZO SOUNDER PROVIDES SEPARATE AND DISTINCT SOUNDS FOR ALARM,
TROUBLE, SUPERVISORY AND CRITICAL PROCESS MONITORING CONDITIONS
PHONE CONNECT ON DETAIL
DMARC
LINE 3
RED-0 w GREEN
(S) .
B V)
TELCO
YELLOW. LACK W
LINESrM RJ CORD 0
LINE 4 Cl-
�
RE iu Q GREEN RE (Q a ,(� GREEN 0
'■LOCK 'BlgfY( 0 {—
YELLOW �� LACK YELLOW 0 LACK
RJ CORD RJ CORD
PRIMARY SECONDARY PRIMARY
LINE LINE LINE
PRIMARY 0 PRIMARY — O
PORT PORT
SECONDARY
PORT
UNIMODE BURGLAR
PANEL PANEL
NOTES:
1. THE UNIMODE PANEL WILL NEVER SEE A LINE
FAULT IF IT IS WIRED BEFORE THE BA PANEL.
2. THE BA PANEL WILL NEVER SEE A LINE FAULT IF IT
IS WIRED TO THE UNIMODES SECONDARY LINE.
3. BA PANEL WILL SEE LINE FAULT IF UNIMODE
SEIZES SECONDARY LINE FOR MORE THAN ABOUT
TWO MINUTES, WHICH IS OK.
SYSTEM OUTPUTS
O
0 O
V�
J1
0
■
TELCO
PRIMARY
LINE
TELCO
SECONDARY
LINE
TRANSFORMER 1--I
TRANSFORMER 2
(IF REQUIRED) —
BATTERY —
120VAC/20A
DEDICATED
CIRCUIT
SUPPLIED
BY EC
0
r7 N
U U U U
a a a
14AWG --- z z z z
0
ECPS--24FS6
OFFICE/PANEL SMOKE DETECTOR
WIRING & TERMINATION DETAIL
TB5 H
TERM 6
PANEL
SMOKE
DETECTOR
TB5
TERM 5
OPERATION MATRIX
SYSTEM OUTPUTS
CONTROL UNIT NOTIFICATION MISC.
ANNUNCIATOR
G<5
�P JQ of Pr'\�Q o0 PS �J G ,�Q- O� p'ta SGP
� P��Q� Pt�� °� U-
11)
PG G� "�� QG C�� '�� QEF � GAJ '�Q-°•�a '��.�C� °��0� ,r`� C,,�J
A B C D E F G H I J K
1
SPRINKLER WATERFLOW
ALARM AUXILIARY CONTACTS SHOWN
ALARM AUXILIARY CONTACTS SHOWN
raven y: EFJ
IN STANDBY
TELCO
PRIMARY
LINE
TELCO
SECONDARY
LINE
TRANSFORMER 1--I
TRANSFORMER 2
(IF REQUIRED) —
BATTERY —
120VAC/20A
DEDICATED
CIRCUIT
SUPPLIED
BY EC
0
r7 N
U U U U
a a a
14AWG --- z z z z
0
ECPS--24FS6
OFFICE/PANEL SMOKE DETECTOR
WIRING & TERMINATION DETAIL
TB5 H
TERM 6
PANEL
SMOKE
DETECTOR
TB5
TERM 5
OPERATION MATRIX
SYSTEM OUTPUTS
CONTROL UNIT NOTIFICATION MISC.
ANNUNCIATOR
G<5
�P JQ of Pr'\�Q o0 PS �J G ,�Q- O� p'ta SGP
� P��Q� Pt�� °� U-
11)
PG G� "�� QG C�� '�� QEF � GAJ '�Q-°•�a '��.�C� °��0� ,r`� C,,�J
A B C D E F G H I J K
1
SPRINKLER WATERFLOW
ALARM AUXILIARY CONTACTS SHOWN
ALARM AUXILIARY CONTACTS SHOWN
raven y: EFJ
IN STANDBY
I
IN
I
DWG File Name:
SB SanfordFL BAFA
CONTACTS TRANSFER DURING ALARM
Title: Fire Alarm Panel & Device
CONTACTS TRA SFERD DURING ALARM
AS INDICATED BY ARROWS
1
2
SMOKE DETECTOR
•
.
14 3
•
.
•
TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY
•
TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY
2
CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS
(EXCLUDING ELEVATOR SD)
CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS
REMOVED OR WHEN TAMPER FEATURE TIMES OUT
REMOVED OR WHEN TAMPER FEATURE TIMES OUT
OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL
OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL
(+)
_
3
MANUAL STATION0
CONTACTS CLOSE
CONTACTS 4
9
CONTACTS CLOSE
CONTACTS Q
IN ALARM
4
0
0
03
4
DUCT SMOKE DETECTOR
0
0
0
0
0
40
4
5
VALVE TAMPER
0
e
0
5
6
FIRE ALARM SYSTEM AC
•
.
•
.
6
POWER FAILURE
7
FIRE ALARM SYSTEM LOW
•
0
•
•
7
BATTERY
8
OPEN CIRCUIT
8
9
GROUND FAULT
«
0
0
0
9
10
WIRE—TO—WIRE SHORT
•
•
•
•
10
(SLC & NAC)
11
WIRE—TO—WIRE SHORT (IDC)
0
0
9
11
12
LOSS OF CARRIER
0
0
12
13
FIRST FLOOR ELEVATOR
•
.
•
.
13
SMOKE DETECTOR
14
SECOND FLOOR ELEVATOR
•
•
•
•
•
14
SMOKE DETECTOR
SYSTEM WIRING DIAGRAM FOR 4 -WIRE DUCT SMOKE DETECTORS
({) F AVAILABLE POWER INPUTS AVAILABLE POWER INPUTS
TO UNIMODE-10
RESETTABLE POWER (—)
9 VO
A B C 9 10 A B C
&� 000
24V 120 24V 120
VAC VAC
1220/240 1220/2401
J
VAC I VAC
a 0 0
1
ALARM
FAN AUXILIARY
SHUTDOWN CONTACTS
I IALARM
FAN AUXILIARY
SHUTDOWN, CONTACTS
I l GR W
16 6 117 7 18 8 16 6 17 7 18 8
!� y iQ_ _ I I (� PAM --2'
NC C NO NO C NC NC C NO NO C NC ! OR Y BU
1 10N
C> C1
C> C<
ALARM AUXILIARY CONTACTS SHOWN
ALARM AUXILIARY CONTACTS SHOWN
raven y: EFJ
IN STANDBY
I
IN
I
DWG File Name:
SB SanfordFL BAFA
CONTACTS TRANSFER DURING ALARM
Title: Fire Alarm Panel & Device
CONTACTS TRA SFERD DURING ALARM
AS INDICATED BY ARROWS
AS INDICATED BY ARROWS
Scale: NTS
SUPERVISORY TROUBLE CONTACTS
I
I SUPERVISORY TROUBLE CONTACTS
14 3
14 3
TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY
TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY
CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS
CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS
REMOVED OR WHEN TAMPER FEATURE TIMES OUT
REMOVED OR WHEN TAMPER FEATURE TIMES OUT
OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL
OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL
(+)
_
ALARM 5 CONTACTS SHOWN I
OPEN IN
INITIATION
ALARM 5 CONTACTS SHOWN
OPEN IN STANDBY
INITIATION
CONTACTS CLOSE
CONTACTS 4
CONTACTS CLOSE
CONTACTS Q
IN ALARM
4
IN ALARM
4
MULTIPLE FAN SHUTDOWN (INTERCONNECT)
1 6 A B C 1 6 A B C
0 E0 0 0 0 0 0
12 16 12 16
FAN
CONTROL
DETECTOR 1 DETECTOR 2
SYSTEM SYSTEM
CONTROL 1 FAN CONTROL
POWER POW
OR
I CONTROL OR
THERMOSTAT U? OTO I I THERMOSTAT
DETECTORS 1111
MAXIMUM
0 0 0 0 0 &&
0 O O O
1 6 A B C
0 0 0 0 0 0 0
12 16
DETECTOR 10
PSYSTEM
A B C D E F G H I J K FFAN L4CONTROL
POWER
CONTROL
I THERMOSTAT
f r n
in h r in nl cifi all identified o Co st uct a
r r i n nt e u ess s e c
'I' f m m s mblies o other info mato co a ed e
This desi n includin specifications, drawings, and desi n concepts is the property of ADT Security Systems, Inc. (ApT), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transferred, copied, ar used to the detriment of ADT without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with ADT. ADT makes no representations as to the operabi ity or accuracy a any syste s, subsyste s, ase p y
9 9 9
EOL RESISTOR
SPECIFIED BY
MANUFACTURER
TRICON
CONSULTING ENGINEERS
777 S. Harbour Island Blvd, STE 870, TAMPA, FL 33602
813 .227.9190 FAX 813. 227. 9195
Certificate of Authorization No. 00008363
SEAL_
DENNIS E. VANN
FL. PE. #57620
SMOKEY BONES
STORE #7632
1000 WP Ball Blvd ■
Sanford, FI
Stamp Area:
REVISIONS
No. Date Description
1.0 103/22/05 REVISED FLOOR PIAN
1.5 10/10/05 SUBMITTALS
tyroIre
tecurity
ADT Security Services, 8607 Roberts
Inc. Systems Sales & Dr. Atlanta, Ga.
Engineering 30328
678-585-5800
Building Type
P -5R
raven y: EFJ
ate: 03/14/05
Checked y: MDS
Date: 03/14/05
DWG File Name:
SB SanfordFL BAFA
Sales Consultant:
Pete Marshall
Title: Fire Alarm Panel & Device
Wiring Diagrams
Fire Alarm Devices & Operation
Matrix
Scale: NTS
Sheet:
FA -1.2