Loading...
HomeMy WebLinkAbout3767 S Orlando AveCITY OF SANFORD PLRMIT AI PLICATION Job Address: .7, -7� 7 Description of Work: Historic District: e,e e Zoning: R�ECE! V :LE, Date: _ _ r//// 0;s- NQS 12005 Value of Work: $_/5' "cy, ac�' Permit Type: Building Electrical // Mechanical—_ Plumbing _ Fire Sprinkler/Alarm Pool Electrical: New Svt-viee — li of AMPS _ 2 0�0 Addition/Alteration _.,____ Change cif Service Temporary Pole __ Mechanical: Residential - Non -Residential Replacetnent __- New (Duet Layout & Energy Calc, Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lincs _ __ Plumbing/Nets, Residential: # of Water Closets _ Plumbing Repair — Residential or Commercial _ Occupancy Type: Residential Commercial fi" Industrial Total Square Footage. Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: Owners Name & Address: s 7 Contractor Name & Address: rr / (Attach Proof of Ownership & Legal Description) 'F pf`o J.ye- _ Phone State License Number.�C Phone & Fax: Contact O l �! - 341� i Yl' Contact Pcrxom: 3 - Phnne: G Gy2 a -15Z Bonding Company: Address: Mortgage Lender: . Address-- Architect/Engineer: ddress:Architect/Engineer: Address: 5 !Tune: Fax: Application is hereby uradc to obtain a pcnnit to do the work and installations as indicated, l cettily that no work ur inslallaliou has conunenced prior to lho issuance of a pcnnit and that all work will be pertonned to meet standards of all Taws regulating construction in thus jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CON DIIONERS, ctc. OWNER'S AFFIDAVIT: I certify that all of the horegoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING'1'O OWNER: YOUR FAILURE TO RECORD A NOTICE, OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT W1111 YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT-. NOTICE: In addition to the requirements of this pennit, there may be additional restrictions applicable to this property that may be (bund in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of pennit is verification that I will notify the owner of the property of the rcquhcm' tra' lorida Lico Lav, FS 713. Signature of Owner/Agent Date nature of Contractor/Agent Date rA lvrin_�t(C.nt PrintOwncr/Agcnt's Namc tactpdAgcn['s amc Signature of -Notary -State of Florida Date Signature of Notary -State of Florida Date N.> 4, DC:l]faR ESLANTON N1Y 0.N• "rir' .;ION # DD '! 813491 Owner/Agent is _ Personally Known to Me or Contractor/Aen 41s' Pcksgjl��ly,l rLy�)ydtaf9 `t %7 _Produced ID T _ Productl J[��„1�'� � rW✓„ ^.�� `r� V�� APPLICATION APPROVED BY: Bldg: Zoning: Utilities: FD: (Imti )Date) (Initial & Date) (Initial & Date) (Initial & Date) Special Conditions:_._ 16000 GENERAL ELECTRICAL REQUIREMENTS A. THE COMPLETE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF THE FOLLOWING CODES & STANDARDS. 1. NFPA 70 NATIONAL ELECTRICAL CODE 2002 ED. 2. NFPA 90A STANDARD TO THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS. 3. NFPA 101 LIFE SAFETY CODE. 4. ANSI A117.1 ACCESSIBILITY CODE. 5. FLORIDA AMERICANS WITH DISABILITIES ACCESSIBILITY IMPLEMENTATION ACT AS DESCRIBED IN ACCESSIBILITY REQUIREMENTS MANUAL, DEPARTMENT OF COMMUNITY AFFAIRS. 6. AMERICANS WITH DISABILITIES ACT. 7. FLORIDA BUILDING CODE 2004. 8. FLORIDA FIRE PREVENTION CODE 2004 Ed. B. 'FURNISH AND INSTALL' AND 'PROVIDE' ARE EQUIVALENT TERMS WHICH INDICATE MATERIAL AND/OR EQUIPMENT SUPPLIED AND INSTALLED BY THIS CONTRACTOR. 'FURNISHED' DENOTES MATERIAL OR EQUIPMENT SUPPLIED BUT NOT INSTALLED BY THIS CONTRACTOR. 'INSTALLED' DENOTES THE SETTING IN POSITION OR CONNECTION OF MATERIAL OR EQUIPMENT BY THIS CONTRACTOR BUT SUPPLIED BY OTHERS. C. IT IS THE REQUIREMENT OF THESE CONTRACT DOCUMENTS TO HAVE THE CONTRACTOR PROVIDE SYSTEMS AND COMPONENTS THAT ARE FULLY COMPLETE AND OPERATIONAL AND FULLY SUITABLE FOR THE INTENDED USE. D. DRAWINGS ARE DIAGRAMMATIC AND SHOULD NOT BE SCALED TO DETERMINE EXACT LOCATIONS. VERIFY ALL LOCATIONS AND REQUIREMENTS OF EQUIPMENT FURNISHED AND/OR INSTALLED BY OTHERS BEFORE ROUGHING IN. E ELECTRICAL SYSTEMS SHALL BE INSTALLED AS A COMPLETE INSTALLATION, INCIDENTAL DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER INSTALLATION AND OPERATION SHALL BE INCLUDED IN THE WORK OF THIS CONTRACTOR. F PREBID SURVEY 1. THIS CONTRACTOR SHALL SURVEY THE JOBSITE PRIOR TO SUBMITTING THEIR BID TO DETERMINE THE FOLLOWING: a- AREAS REQUIRING DEMOLITION, TEMPORARY POWER, RELOCATING, ETC, WHICH ARE INADVERTENTLY NOT SHOWN ON THE DRAWINGS. b. PROBLEMS WITH WORK SEQUENCE, 2. ANY UNUSAL CONDITIONS NOT SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE ENGINEER PRIOR TO BIDDING, G. ACCEPTABLE MANUFACTURERS: THE LISTING OF A MANUFACTURER AS "ACCEPTABLE" UNDER ANY DIVISION 16 REQUIREMENTS DOES NOT IMPLYAUTOMATIC APPROVAL ITIS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ANY SUBMITTALS MADE ARE FOR PRODUCTS THAT MEET OR EXCEED THE SPECIFICATIONS INCLUDED HERE. H. UPON COMPLETION OF THE WORK, BUT BEFORE FINAL ACCEPTANCE OF THE SYSTEM AND REQUEST FOR FINAL PAYMENT, FURNISH THE OWNER, FOR APPROVAL, OPERATION AND MAINTENANCE MANUALS IN LOOSE-LEAF BINDERS. PROVIDE A MINIMUM OF 6 SETS. I PROVIDE OWNER WITH A RECORD SET OF AS -BUILT DRAWINGS FROM A DESIGNATED MARKED -UP SET OF BLUELINES. J. PROVIDE TEMPORARY ELECTRICAL POWER TO JOBSITE FOR THE DURATION OF THE PROJECT. K. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR ALL ELECTRICAL ITEMS THE SHOP DRAWINGS SHALL BE SUBMITTED COMPLETE FOR ALL ELECTRICAL ITEMS. INCOMPLETE SUBMITTALS WILL BE RETURNED WITHOUT BEING REVIEWED OR THE CONTRACTOR SHALL AGREE TO PAY THE ELECTRICAL ENGINEER DIRECTLYAT AN HOURLY RATE OF $95.00 TO REVIEW SUBSEQUENT SUBMITTALS. SHOP DRAWING RE -SUBMITTALS DUE TO REJECTIONS FOR NOT SUBMITTING THE SPECIFIED ITEMS ARE ALSO SUBJECT TO THE HOURLY REVIEW FEE. L DIVISION 16 SUB -CONTRACTOR SHALL REVIEW DIVISION 15 SHOP DRAWINGS AND VERIFY EQUIPMENT VOLTAGE, PHASE AND AMPS PRIOR TO ROUGH -IN OF ALL EQUIPMENT. M ALL EQUIPMENT, DEVICES, ETC. FURNISHED BY ELECTRICAL CONTRACTOR SHALL BE U.L LISTED (OR EQUIVALENT NATIONAL TESTING AGENCY) FOR ITS INTENDED PURPOSE. INFORM OWNER THAT ALL OWNER FURNISHED EQUIPMENT, DEVICES, ETC. MUST ALSO HAVE A UL LISTING (OR EQUIVALENT LISTING). N. ALL ELECTRICAL COMPONENTS (CONDUIT, WIRE, FITTINGS, SUPPORTS, CIRCUIT BREAKERS, LAMPS, ETC.) PROVIDED AND INSTALLED IN THIS PROJECT SHALL BE BRAND NEW. RE -USE OF EXISTING COMPONENTS WILL NOT BE APPROVED. 16020 ELECTRICAL IDENTIFICATION A. PROVIDE CABLE/CONDUCTOR IDENTIFICATION BANDS. B. PROVIDE ENGRAVED PLASTIC LAMINATE SIGNS, WHITE LETTERING ON A BLACK BACKGROUND, FOR EACH UNIT OF THE FOLLOWING CATEGORIES OF ELECTRICAL WORK SWITCHBOARDS, MOTOR STARTERS, TRANSFORMERS, PANELBOARDS DISCONNECTS, AND JUNCTION BOXES NAME PLATES SHALL IDENTIFY PANEL DESIGNATION (NAME), VOLTAGE, PHASE AND WIRE CONFIGURATION. C. UNDERGROUND CABLE/CONDUIT IDENTIFICATION PLASTIC LINE MARKERS SHALL BE PROVIDED THE CONTINUOUS TRENCH LENGTH. 16040 ELECTRICAL DEMOLITION AND ALTERATIONS A. ANY EXISTING CIRCUITS OR EQUIPMENT NOT SHOWN ON DRAWINGS AND WHICH ARE LOGICALLY EXPECTED TO BE CONTINUED IN SERVICE SHALL BE RECONNECTED IN AN APPROVED MANNER. B. WIRING TO ELECTRICAL EQUIPMENT BEING DISCONNECTED SHALL BE REMOVED BACKTO THEIR OVERCURRENT DEVICE OR BACK TO NEAREST ACTIVE JUNCTION BOX. C. CONTRACTOR SHALL PROVIDE SUPPORT FOR EXISTING CONDUIT IN REMODELED AREA THAT IS TO REMAIN AND IS NOT PROPERLY SUPPORTED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. D. EXCEPT FOR CONDUIT, CONDUCTORS AND MISCELLANEOUS HARDWARE, ALL ELECTRICAL EQUIPMENT SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE STORED OR DISPOSED OF AS DIRECTED BY OWNER, A. MINIMUM SIZE CONDUIT SHALL BE 112". DOES NOT APPLY TO MC CABLE. B. CONDUIT SHALL BE MC CABLE, ELECTRICAL METALLIC TUBING, OR RIGID GALVANIZED STEEL CONDUIT. SCHEDULE 40 PVC CONDUIT IS ALLOWED FOR CONDUITS IN/UNDER THE SLAB AND UNDERGROUND. C. ALL CONDUIT SHALL BE CONCEALED. CONDUIT SHALL BE EMT IN INTERIOR AREAS, AND RIGID GALVANIZED STEEL CONDUIT IN EXTERIOR AREAS. D. COORDINATE ROUTING (LOCATION) OF CONDUIT WITH HVAC DUCTWORK, PLUMBING PIPING AND SPRINKLER PIPING. E. SECURE CONDUIT IN PLACE WITH CORROSION -PROOF ALLOY STRAPS AT SPACINGS AS REQUIRED BYN.E.C. CONDUIT SHALL BE SECURED TO BUILDING STRUCTURE. F INSTALL FLEXIBLE STEEL CONDUIT NOT OVER 3' LONG TO MOTORS, TRANSFORMERS AND EQUIPMENT SUBJECT TO VIBRATION. G. INSTALL LIQUID -TIGHT FLEXIBLE CONDUIT NOT OVER 3' LONG WHERE SUBJECT TO MOISTURE, DIRT OR FUMES. H TYPE MC CABLE SHALL BE OF THE INTERLOCKING JACKET TYPE. CABLE SHALL BE SUPPORTED AT NOT MORE THAN SIX-FOOT INTERVALS, AND ALL FITTINGS SHALL BE IDENTIFIED FOR USE WITH SAID CABLE. MC CABLE SHALL NOT BE USED FOR SERVICE ENTRANCE OR IN EXPOSED AREAS. MC CABLE MAYBE USED ABOVE DROP CEILINGS AND IN INTERIOR PARTITIONS. 1. CONTRACTOR SHALL MINIMIZE FLOOR SLAB PENETRATIONS. J. ALL CONDUIT RUNS SHALL BE DESIGNED TO PRESENT A NEAT AND ORDERLY APPEARANCE, RUNNING LINES PARALLEL WITH BUILDING STRUCTURE OR WALLS K. ROOFTOP UNITS AND EXHAUST FANS ARE TO BE WIRED THROUGH THE ROOF CURBS OR UTILIZE FACTORY -FABRICATED ROOF PIPING CURBS PITCH POCKETS ARE NOT ALLOWED. L ROMEX CABLE IS NOT PERMITTED. M. CONDUIT SHALL BE ROUTED PERPENDICULAR THROUGH RATED WALLS. PROVIDE PROPER 16120 WIRES, CABLES AND CONNECTORS A. ALL CONDUCTORS SHALL BE COPPER WITH 600V 90°C THHN/THWN INSULATION. B. USE SOLID CONDUCTOR, SINGLE CONDUCTOR, NO. 12 AWG MINIMUM FOR GENERAL USE WIRING. C. USE STRANDED CONDUCTOR, SINGLE CONDUCTOR NO. 12 AWG AND LARGER, FOR MOTORS AND OTHER INSTALLATIONS WHERE VIBRATION IS GENERATED. D. COLOR -CODING SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM, FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITRY. ALL WIRING SHALL BE COLOR -CODED AS FOLLOWS: 208/120 VOLT PHASE A -BLACK PHASE B -RED PHASE C -BLUE NEUTRAL -WHITE E A STANDARD 500V MEGGER INSULATION TEST SHALL BE MADE AND RECORDED FOR ALL RESULTS TO ENGINEER FOR REVIEW. FEEDER CIRCUITS. PROVIDE COPY OF TEST D F. PROVIDE LUGS FOR FEEDER SIZES INDICATED ON DRAWINGS OR AS REQUIRED. G. WIRE SIZE FOR 120V BRANCH CIRCUITS SHALL BE PER THE FOLLOWING LENGTH OF RUNS: 1. 0 TO 50 FT RUN FROM PANELBOARD TO FIRST OUTLET, NO. 12 AWG MINIMUM. 2. 51 TO 100 FT RUN., INCREASE ONE WIRE SIZE, I.E. NO. 12 AWG BECOMES NO. 10 AWG TO FIRST OUTLET. 3. 101 TO 150 FT RUN: INCREASE TWO WIRE SIZES, I. E. NO. 12 AWG BECOMES NO. 8 AWG TO FIRST OUTLET. 4. 151 AND ABOVE. WIRING SHALL BE SIZED FOR 3% MAXIMUM VOLTAGE DROP. 16130 BOXES A. WALL OUTLET BOXES SHALL BE 4 INCH SQUARE WITH A TOTAL DEPTH OF LESS THAN 2-112" GALVANIZED PRESSED STEEL WITH PLASTER RINGS OR GANG COVER, OR SIZED AS REQUIRED. R WHERE MORE THAN TWO SWITCHES OR DEVICES ARE LOCATED AT ONE POINT, USE GANGED BOXES AND COVERS. C. ALL BOXES FOR ELECTRICAL EQUIPMENT SHALL HAVE COVERS. D. DO NOT INSTALL BOXES BACK TO BACK OR THROUGH WALL OFFSET OUTLET BOXES ON OPPOSITE SIDES OF WALL A MINIMUM OF 12 INCHES OR ON OPPOSITE SIDES OF STUD IN PARTITION WALLS. WHERE BACK TO BACK BOXES CANNOT BE AVOIDED, PROVIDE GYPSUM BOARD BETWEEN BOXES. PROVIDE PUTTY PADS ON ALL BOXES WHERE REQUIRED. 16140 WIRING DEVICES A. WIRING DEVICES SHALL BE MANUFACTURED BY HUBBELL, BRYANT OR LFVITON. B. RECEPTACLES SHALL BE HEAVY DUTY DUPLEX, 2 POLE, 3 WIRE, GROUNDING, 20 AMP, 125 VOLT, DESIGNED FOR SIDE AND BACK WIRING WITH NEMA CONFIGURATION 5-20R. DESIGN SELECTION. HUBBELL CR -5362-L C. RECEPTACLES NEXT TO DATA OUTLETS SHALL BE TVSS. DESIGN SELECTION: HUBBELL 5360 -ISA. D. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES SHALL BE NEMA 5-20R AND EQUAL TO HUBBELL GFR -5352-L E. SWITCHES SHALL BE HEAVY DUTY SINGLE POLE AC QUIET SWITCHES, 20 AMPERES, EQUAL TO HUBBELL CS- 1221-1, CS- 1223-1 (THREE-WAY), CS- 1224-1(FOUR-WAY). F. PROVIDE SMOOTH NYLON COVERS FOR ALL DEVICES. 16155 MOTOR STARTERS A. PROVIDE STARTER OF NEMA SIZE AND VOLTAGE RATING COMPATIBLE WITH MOTOR. B. MANUFACTURERS SHALL BE G. E., SQUARED' OR SIEMENS. C. AC FRACTIONAL HORSEPOWER MANUAL STARTERS, 2 POLE, SIZE AND RATING AS REQUIRED. EQUIP WITH MANUALLY OPERATED TOGGLE -MECHANISMS, AND WITH ONE PIECE MELTING ALLOY TYPE THERMAL UNITS, GREEN PILOT LIGHT, AND SWITCH CAPABLE OF BEING PAD- LOCKED OFF. ENCLOSE STARTER IN NEMA TYPE 1 ENCLOSURE. SQUARE 'D' TYPE'P. D. MANUAL MOTOR STARTING SWITCHES, 2 POLE, TOGGLE TYPE WITHOUT OVERLOAD PROTECTION, SIZE AND RATING AS REQUIRED. NEMA 1 ENCLOSURE WITH SWITCH TOGGLE GUARD WITH OFF LOCK -OUT FEATURE, SQUARED, TYPE'K. E MEGGER CHECK PHASE -TO -PHASE AND PHASE -TO -GROUND INSULATION LEVELS. DO NOT MEGGER CHECK SOLID-STATE EQUIPMENT. TEST EACH MOTOR AND RECORD NAMEPLATE DATA, OVERLOAD RELAY EQUIPMENT, PROTECTIVE RELAY SETTING, VOLTAGE AND CURRENT PHASE READINGS AND DIRECTION OF ROTATION. F. MAGNETIC COMBINATION NON -REVERSING STARTERS WITH CIRCUIT BREAKERS. EQUIP STARTERS WITH BLOCK TYPE MANUAL RESET OVERLOAD RELAYS. PROVIDE ONE NORMALLY OPEN AND TWO NORMALLY CLOSED AUXILIARY CONTACTS. PROVIDE MINIMUM 50VA CONTROL VOLTAGE TRANSFORMER WITH VOLTAGE AS REQUIRED BUT NOT TO EXCEED 120V PROVIDE ENCLOSURE IN SIZE AND NEMA RATING AS REQUIRED. EQUIP WITH PHASE FAILURE, UNDERVOLTAGE, AND PHASE UNBALANCE RELAY PROTECTION. PROVIDE OPERATING HANDLE FOR DISCONNECT SWITCH MECHANISM WITH INDICATION AND CONTROL OF SWITCH POSITION, WITH ENCLOSURE DOOR EITHER OPENED OR CLOSED, AND CAPABLE OF BEING LOCKED IN OFF POSITION, WITH A PADLOCK. SQUARED' CLASS 8539. 16160 PANELBOARDS A. PANELBOARDS SHALL BE MANUFACTURED BY SQUARE 'D', GENERAL ELECTRIC, OR ITE SIEMENS. B. PROVIDE LIGHTING AND APPLIANCE PANELBOARDS, AND POWER DISTRIBUTION PANELBOARDS WITH DEAD FRONT COVERS, FULL SIZE NEUTRAL AVD BOLT -ON HEAVY DUTY, QUICK MAKE, QUICK BREAK CIRCUIT BREAKERS. PANELBOARDS SHALL BE U.L. LISTED. C. INSTALL PANELBOARDS SO TOP BREAKER IS NOT HIGHER THAN 6'-0" ABOVE FLOOR. D. CONTRACTOR SHALL BALANCE PHASES IN PANELBOARD SO THAT LOAD IMBALANCE DOES NOT EXCEED 10%. E. PANELBOARD SHALL INCLUDE COMPLETE TYPEWRITTEN DIRECTORY. F. PROVIDE SPARE CONDUITS TO CEILING CAVITY FOR SPARES/SPACES IN RECESSED PANELBOARDS. PROVIDE (1) 314"C. FOR EVERY 3 SPACES. G. PROVIDE U. L LISTED BREAKERS FOR EXISTING PANELBOARDS TO MATCH MANUFACTURER AND AIC RATING. H. PROVIDE AFCI�ARC FAULT CIRCUIT INTERRUPTER) BREAKERS FOR ALL CIRCUITS SERVING BEDROOMS 0 DWELLING UNITS PER N.E.C. 210.12- 1, ALL BREAKERS SERVING MECHANICAL, REFRIGERATION, OR OTHER EQUIPMENT WHERE REQUIRED, SHALL BE HACR RATED. J. BREAKERS WITH HID LIGHTING LOADS SHALL BE HID RATED. K. BREAKERS SERVING CIRCUITS UNDER KITCHEN HOODS SHALL BE SHUNT -TRIP TYPE, 16161 MOTOR CONTROL CENTERS A. PROVIDE AS SHOWN ON POWER ONE -LINE DIAGRAM. B. INCOMING: SERVICE TO MAIN DEVICE SHALL BE 20BY/12OV, 3 PHASE, 4 WIRE. C. EQUIPMENT SHALL HAVE AN INTEGRATED AIC RATING MINIMUM OF 42KAIC. D. PROVIDE ANYADDITIONAL REQUIREMENTS AS REQUIRED ON POWER ONE -UNE DIAGRAM. E. DESIGN SELECTION: SIEMENS 16170 MOTOR AND CIRCUIT DISCONNECTS A. DISCONNECT SWITCHES MAYBE GENERAL DUTY FOR 24OV, B. PROVIDE RAIN -TIGHT HUBS FOR EXTERIOR DISCONNECTSS, C. PROVIDE CLASS R REJECTION FUSE CLIPS AND CLASS R FUSES. D. FUSES SHALL BE MANUFACTURED BY BUSSMAN, LITTLE OR GOULD-SHOUWMUT. E. SERVICE DISCONNECT SWITCH SHALL BE HEAVY DUTY TYPE. 16190 SUPPORTING DEVICES SLEEVES AND FIRE SAFING/SEALANTS. A. LIGHTING FIXTURES SHALL BE SUPPORTED FROM BUILDING STRUCTURE AND NOT FROM N. PROVIDE UL APPROVED FIRE SEALS FOR ALL FIRE RATED WALL AND FLOOR PENETRATIONS CEILING GRID. SECURE A MINIMUM OF TWO CORNERS (OPPOSITE) TO STRUCTURE ABOVE 16115 CONDUIT FITTINGS WITH CHAIN. 8. FASTEN CONDUIT TO STRUCTURAL PARTS OF BUILDING. A. COMPRESSION TYPE OR SETSCREW TYPE SHALL BE UTILIZED. 16450 GROUNDING B. PROVIDE PROPER EXPANSION FITTINGS WHEN CROSSING BUILDING EXPANSION LINES. A. PROVIDE INSULATED GROUND CONDUCTORS IN ALL CONDUITS. B. PROVIDE GROUNDING BUSHINGS FOR FEEDER CONDUITS. C. SERVICE GROUND RESISTANCE SHALL BE MEASURED WITHOUT DEPENDING ON WATER PIPING SYSTEM AND SHALL BE 25 OHMS OR LESS, IF GREATER THAN 25 OHMS, DRIVE ADDITIONAL GROUND RODS TO OBTAIN REQUIRED RESISTANCE. D. GROUND METAL LIGHTING POLES AS REQUIRED BY N.E. C. ELECTRICAL SPECIFICATIONS NOT TO SCALE NEW CT CABINET (SIZE AS REQUIRED BY UTILITY COMPANY) 3R SYMBOL DESCRIPTION. POWER MOUNTING HEIGHT.' SYMBOL DESCRIPTION DEMO. AND RENO. ABBREVIATIONS On DUPLEX RECEPTACLE. 18" AFF Ow DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER BACKSPLASH 6" ABOVE COUNTER QUADRAPLEX (DOUBLE DUPLEX) RECEPTACLE 18" AFF QUADRAPLEX (DOUBLE DUPLEX) RECEPTACLE, MTD. ABOVE COUNTER. 6" ABOVE COUNTER gm DUPLEX GROUND FAULT CIRCUIT INTERRUPTED RECEPTACLE. 18" AFF E� DUPLEX GROUND FAULT CIRCUIT INTERRUPTED RECEPTACLE -MOUNTED 6" ABOVE COUNTER ABOVE COUNTER BACKSPLASH. ® SPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AS SHOWN. 1 LT' AFF 0 JUNCTION BOX WITH BLANK PLATE; BRACKET INDICATES WALL MOUNTED. rr PANELBOARD. 6"-6" TO TOP = RECESSED FLUSH -MOUNTED PANELBOARD, FRONT OF PANEL INDICATED 6"-6" TO TOP BY LONGER EDGES OF SYMBOL Q METER SOCKET, PROVIDE PER UTILITY COMPANY REQUIREMENTS. EQUIPMENT SYMBOLS MOTOR AND CONNECTION. EQUIPMENT TYPE AS NOTED, REFER TO MOTOR CONNECTION SCHED. COORDINATE WITH INSTALLED EQUIPMENT a SAFETY DISCONNECT SWITCH -30A, 30, 48OV, NF, HD, NEMA 1, U.N.O. IaM MOTOR STARTER. COMBINATION MOTOR STARTER & NON-FUSED DISCONNECT SWITCH, UNLESS NOTED OTHERWISE. "P'= FUSED; "NP' = NON-FUSED. CONDUIT, RACEWAYAND WIRING + EACH CIRCUIT SHALL CONSIST OF PHASE, NEUTRAL AND GROUND CONDUCTORS. FOR LIGHTING CIRCUITS PROVIDE REQUIRED SWITCH LEGS TO ACHIEVE SWITCHING INDICATED ON PLANS, CONTRACTOR MAY COMBINE CIRCUITS INTO A COMMON HOMERUN CONSISTING OF A MAXIMUM OF A COMMON NEUTRALIGROUND AND (3) PHASE CONDUCTORS (A, 8 AND C PHASE). HOWEVER, A SEPARATE NEUTRAL SHALL BE PROVIDED FOR ALL CIRCUITS SERVING COMPUTERS (DATA) CIRCUITS. SERVICING DATA IS DEFINED AS ANY RECEPTACLE' NEXT TO A DATA OUTLET OR SPECIFICALLY SERVING A DATA PIECE OF EQUIPMENT. HOME RUN TO PANEL, NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. ALL HOMERUNS SHALL BE # 10 AWG, 314"C., MINIMUM. - - - INDICATES DEVICE(S) CONNECTED TO SAME CIRCUIT, BUT DIFFERENT SWITCHING CONTROLS. - -- I� GROUNDING CONDUCTOR. -- - CONDUIT IN/UNDER SLAB. ---I CONDUIT CAP. <E> EXISTING TO REMAIN. <K> EXISTING TO BE REMOVED. < RD > REMOVE DEVICE ONLY, FOR CONNECTION OF NEW DEVICE IN SAME LOCATION. <KL> EXISTING TO BE RELOCATED. < N > NEW WORK - NOT USED WHERE WORK IS OBVIOUSLY NEW. < N L> NEW LOCATION OF EXISTING TO BE RELOCATED. <ND> NEW DEVICE, ETC. IN EXISTING DEVICE LOCATION. SCREENED LINES INDICATE EXISTING EQUIPMENT TO REMAIN. --DARK DARK LINES INDICATE NEW WORK XX -LINES WITH X'S INDICATE EXISTING EQUIPMENT TO BE REMOVED. GENERAL NOTES (APPLIES TO ALL DIVISION 16000 DRAWINGS) 1. WHERE THE REQUIREMENTS OF ANOTHER DIVISION, SECTION, OR PART OF THE SPECIFICATIONS EXCEED THE REQUIREMENTS OF THIS DIVISION, THOSE REQUIREMENTS SHALL GOVERN. ENGINEER SHALL HAVE FINAL DECISION OF WHICH REQUIREMENT SHALL GOVERN. 2. ALL FLOOR, WALL AND ROOF PENETRATIONS SHALL MAINTAIN THE ENVIRONMENTAL AND FIRE RATING OF THE STRUCTURE, ROOF PENETRATIONS SHALL BE COORDINATED WITH THE ROOFING CONTRACTOR TO MAINTAIN THE ROOFING WARRANTY. PITCH POCKET ROOF PENETRATIONS ARE NOT PERMITTED. 3. ALL MOUNTING HEIGHTS SHOWN SHALL BE TO CENTER UNE OF DEVICE BACKBOX FROM FINISHED FLOOR. 4. ALL COMMUNICATION CONDUIT SHALL HAVE WIDE SWEEPING BENDS. 5. ALL COMMUNICATION CONDUIT SHALL BE IDENTIFIED BYA DISTINCTIVE NUMBER AND LABELED AT BOTH ENDS. 6. ALL CONDUIT IN SLAB/BELOW SLAB SHALL BE 314" MINIMUM. 7. ALL SYMBOLS PRESENTED MAY NOT NECESSARILY BE USED ON THESE DRAWINGS. ABBREVIATIONS A AMPS/AMPERAGE IUC IN -USE COVER AFF ABOVE FINISHED FLDOR IWH INSTANTANEOUS WATER HEATER AHJ AUTHORITY HAVING JURISDICTION KW KILOWATTS AHU AIR HANDLER UNIT KVA KILO VOLTAMPERES C./CDT. CONDUIT MH METAL HALIDE C.B. CIRCUIT BREAKER MNT. MOUNTING CLG CEILING MCB MAIN CIRCUIT BREAKER CU CONDENSING UNIT MLO MAIN LUGS ONLY DISC DISCONNECT MMS MANUAL MOTOR STARTER DN DOWN NEC NATIONAL ELECTRICAL CODE EC ELECTRICAL CONTRACTOR NF NON-FUSED EF EXHAUST FAN RGS RIGID GALVANIZED STEEL EQPT EQUIPMENT RTU ROOF -TOP UNIT EWC ELECTRIC WATER COOLER ST SHUNT TRIP EWH ELECTRIC WATER HEATER SW SWITCH FVNR FULL VOLTAGE NON REVERSING STARTER TTB TELEPHONE TERMINAL BACKBOARD GC GENERAL CONTRACTOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR GFI GROUND FAULT INTERRUPTOR UNO UNLESS NOTED OTHERWISE GND.1G. GROUND W WATTS HPS HIGH PRESSURE SODIUM WP WEATHERPROOF (NEMA 3R) HP HORSEPOWER V VOLTS HRS HORSEPOWER RATED SWITCH XFMR TRANSFORMER IG ISOLATED GROUND 0 PHASE IMC INTERMEDIATE METAL CONDUIT Q DRAWING NOTE SYMBOL LEGEND AND GENERAL NOTES NOT TO SCALE DRYER MOTORS 208V, 15HP, 30, 48.3FLA (TYPICAL OF 4) PANEL 'A' 6013 (REPLACE EXISTING LOADCENTER PANEL 'B' (-4#3, 1#3G. -2"C, 50 PANEL 'D' PANEL 'L' WITH NEW PANELBOARD) (EXISTING) DETAIL PANEL LUBE ROOM PANEL 225A MLO 400A MLO 3#4, 1#8G.-1 UTILITY TRANSFORMER 208/12OV, 30, 4W SERVICE 16 469 SHORT CIRCUIT AMPS VOLTS: 2081120 NEWLURE ROOM PANEL SOUHCE: NEW MOTOR CONTROL PANEL EXISTING FPL M METER #6LL8543 3R (PROVIDE NEW METER SOCKET IF REQUIRED) CONNECTED DEMAND j 3R UTILITY PRIMARY EXISTING UTILITY TRANSFORMERS ARE POLE MOUNTED. CONTACT CHARLIE JOHNSON WITH FPL (407.328.1922) FOR FURTHER COORDINATION ITEMS (EXISTING MAXIMUM KW DEMAND FROM UTILITY WAS 96.0 KW OR 266 AMPS). NOTE: ORIGINAL SERVICE WAS 600 AMPS FEEDING PANEL A', PANEL 'B' AND 'MCC I'. 100 9013 4#500kcmil - 3 112"C. (RE -USE 2 OF THE EXISTING 3 112" PVC CONDUITS IF POSSIBLE) 40013 3Rl l I 3R _E_ .._..._ 3R POWER ONE -LINE DIAGRAM NOT TO SCALE #310 518"x10' GROUND ROD '10013 ! EXISTING MOTOR DR CONTROL CENTER 'MCC P VOLTS: 2081120 NEWLURE ROOM PANEL SOUHCE: NEW MOTOR CONTROL PANEL I S 1 ' CONNECTED DEMAND j CENTER 'MCC4' N z SERVICE #1 "' i 4#500kcmil, 1#3G. -4"C. NEW 400 AMP, 30, 4W 24.0 66.62 PANEL 'S1' 2 CONTRACTOR SHALL VERIFY SIZE OF NEW EQUIPMENT AND FIELD LAYOUT 3 NEW SERVICES AND CT CABINET DESCRIPTION: o 42K AIC UTILITY SERVICE #2 SERVICE #3 KVA C BUS RATING: 400A MC8 KVA AMPS 100K AIC 190K AIC 111.0 308.11 10013 UEMAND LOAD: 240V, 400AMP, 30, 4W SURFACE 200/3 LIGHTING 400-3 40013 HD FUSED DISCONNECT SWITCH 1.0 LOADS 0.0 m IN NEMA 3R ENCLOSURE SPACE 15013 CKT. NO, KVA B 4#500kcmil - 3 112"C. (RE -USE 2 OF THE EXISTING 3 112" PVC CONDUITS IF POSSIBLE) 40013 3Rl l I 3R _E_ .._..._ 3R POWER ONE -LINE DIAGRAM NOT TO SCALE #310 518"x10' GROUND ROD '10013 ! EXISTING MOTOR DR CONTROL CENTER 'MCC P PANEL V VOLTS: 2081120 NEWLURE ROOM PANEL SOUHCE: PANEL'SP PANEL I S 1 ' CONNECTED DEMAND BUS RATING: 100A MLO KVA AMPS SINGLE PANEL YES VOLTS: 208/120 GROUND BUS: YES DEMAND LOAD: 24.0 66.62 SERVICE 711 PANEL CONTRACTOR SHALL VERIFY SIZE OF NEW EQUIPMENT AND FIELD LAYOUT 3 NEW SERVICES AND CT CABINET DESCRIPTION: CKT NO. SOURCE: UTILITY PHASE 30, 4W KVA R KVA C BUS RATING: 400A MC8 KVA AMPS SINGLE PANEL YES CONN. LOAD: 111.0 308.11 GROUND BUS: YES UEMAND LOAD: 111.0 308.11 MOUNTING SURFACE SPACE LIGHTING LOADS m 1.0 LOADS 0.0 m 4 SPACE DESCRIPTION., CKT. NO, KVA A KVA B KVA VIPS/P01 VPSIPOtKVA C A KVA B KVA C CKI. NO. DESCRIPTION: RECEPTACLES PANEL'D 1 11.0 = = 150/3 13 5.0 = = 2 SPARE LOADS = -------- 3 0.0 1 To = ---- ---- 5.0 = 4 ----- - 2.0 -------- 5 12 SPACE 11.0 13 r 5.0 6 SPACE r PANEL'L' 7 6.0 15 10013 0.0 m 0.0 8 SPACE SPACE: ------ 9 6.0 3.0 --- 0.0 18 10 SPACE 19 ------ 11 r 6.0 --- 20 = 0.0 12 SPACE To PANEL 'A' 13 15.0 r 20013 0.0 r = 14 SPACE ------- 15 SPACE 15.0 2011 r 0.0 m 16 SPACE 26 ------- 17 27 15.0 --- 2011 r 0.0 0.0 18 SPACE SPARE SPACE 19 0.0 1.0 20/1 jFM 20/1 0.0 30 = 20 SPACE 8.00 SPACE 21 0.00 0.0 2011 m 0.0 m 22 SPACE SPACE 23 0.0 m r 0.0 24 SPACE SPACE 25 3200 32.00 32.00 1 5.00 5.00 5.00 26 KVA CONNECTED 37.00 37.00 137.00 111.0 PANEL V VOLTS: 2081120 NEWLURE ROOM PANEL SOUHCE: PANEL'SP PANEL R CONNECTED DEMAND BUS RATING: 100A MLO KVA AMPS SINGLE PANEL YES VOLTS: 2081127 GROUND BUS: YES DEMAND LOAD: 24.0 66.62 EXTERIOR DETAIL PANEL CONTRACTOR SHALL VERIFY SIZE OF NEW EQUIPMENT AND FIELD LAYOUT 3 NEW SERVICES AND CT CABINET DESCRIPTION: CKT NO. SOURCE: PANEL'S 1' PHASE: 30, 4W KVA R KVA C BUS RATING: P25A MLO KVA AMPS SINGLE PANEL: YES CONN. LOAD .?3.0 91.60 GROUND BUS: YES DEMAND LOAD: 33.0 91.60 MOUNTING: SURFACE SPACE LIGHTING LOADS m 1.0 LOADS 0.0 m 4 SPACE DESCRIPTION. CKT N0. KVA A KVA B KVA WPS/PU-'MPS/PPOII KVA C A KVA 8 KVA C CKT NO. DESCRIPTION: RECEPTACLES VACUUM MOTOR 1 5.0 = = 4513 0.0 = = 2 SPACE = ------- 3 0.0 5.0 m I -- I m 0.0 = 4 SPACE 2.0 ----- 5 12 SPACE 5.0 13 2.0 0.0 6 SPACE r VACUUM MOTOR 7 5.0 15 4513 0.0 m 0.0 8 SPACE SPACE: -------- 9 5.0 3.0 --- 0.0 18 to SPACE 19 ------- I1 r 5.0 20 = 0.0 12 SPACE To RECEPTACLES 13 1.0 22 2011 0.0 = = 14 SPACE LIGHTING 15 SPACE 1.0 2011 1.0 0.0 m 16 SPACE 26 RECEPTACLES 17 27 1.0 2011 2011 r 0.0 0.0 18 SPACE SPARE SPARE 19 0.0 1.0 20/1 jFM 20/1 0.0 30 = 20 SPACE 8.00 SPARE 21 0.00 0.0 2011 m 0.0 m 22 SPACE SPARE 23 0.0 2011 m r 0.0 24 SPACE SPACE 25 0.0 0.0 = = 26 SPACE SPACE 27 0.0 0.0 28 SPACE SPACE 29 0.0 0.0 30 SPACE I Too 11.00 11.00 r 0.00 0.00 0.00 KVA CONNECTED 11.00 11.00 11.00 33.0 PANEL V VOLTS: 2081120 NEWLURE ROOM PANEL SOUHCE: PANEL'SP PHASE: 30.4W ROOM PANEL INSTALLATION AND WIRING, INCLUDING FEEDER, SHALL BE INSTALLED /N ACCORDANCE CONNECTED DEMAND BUS RATING: 100A MLO KVA AMPS SINGLE PANEL YES CONN. LOAD: 24.0 66.62 GROUND BUS: YES DEMAND LOAD: 24.0 66.62 MOUAIT1W SURFACE LOADS IOADS CONTRACTOR SHALL VERIFY SIZE OF NEW EQUIPMENT AND FIELD LAYOUT 3 NEW SERVICES AND CT CABINET DESCRIPTION: CKT NO. KVA A KVA B KVA PS/Rol VPS/POL KVA C A KVA R KVA C CKT NO. DESCRIPTION LIGHTING 1 1,0 = = 2011 0.0 = r 2 SPACE LIGHTING 3 m 1.0 1 2011 0.0 m 4 SPACE RECEPTACLES 5 = = 1.0 2011 = 0.0 6 SPACE RECEPTACLES 7 1.0 r= 2011 0.0 m m 8 SPACE AIR COMPRESSOR (VERIFYACTUAL REQUIREMENTS) 9 = 2.0 = *13 0.0 10 SPACE -------- 11 m m 2.0 0.0 12 SPACE -------- 13 2.0 r = -.-- 0.0 r 14 SPACE TIRE BALANCER (VEMFYACTUAL REQUIREMENTS) 15 3.0 = "l3 m 0.0 16 SPACE: -------- 17 3.0 --- 0.0 18 SPACE 19 3.0 r ---- 0.0 20 SPACE SPARE 21 To 2011 0.0 22 SPACE SPARE 23 1.0 2011 0.0 24 SPACE SPARE 25 1.0 2711 0.0 26 SPACE SPARE 27 1.0 2011 r 0.0 28 SPACE SPARE 29 1.0 20/1 jFM 0.0 30 SPACE 8.00 8.00 8.00 0.00 0.00 0.00 KVA CONNECTED 8.00 8.00 8.00 24.0 POWER ONE -LINE DIAGRAM NOTES: 0 PROVIDE COMBINATION MOTOR STARTER AND DISCONNECTING MEANS, EITHER FUSED DISCONNECT OR NOV. 8, 2005 CIRCUIT BREAKER IS ACCEPTABLE. OLUBE ROOM PANEL INSTALLATION AND WIRING, INCLUDING FEEDER, SHALL BE INSTALLED /N ACCORDANCE CONNECTED DEMAND WITH N.E.C. 511. PROVIDE SEAL -OFF FITTINGS IN FEEDER CONDUIT IN ACCORDANCE WITH N.E.C. 511. OPANEL 'B' NAS AN EXISTING CONNECTED LOAD OF 250 AMPS. THEREFORE, PANEL HAS SPARE CAPACITY IF KW NEEDED FOR CONTRACTOR TO FIELD ADD ADDITIONAL BRANCH CIRCUITS, BUT SHALL NOT EXCEED 130 AMPS COLD MORE OF LOAD. BUILDING WATER STEEL PIPE CONTRACTOR SHALL VERIFY SIZE OF NEW EQUIPMENT AND FIELD LAYOUT 3 NEW SERVICES AND CT CABINET 5/8°x10' 04,\ ON EXTERIOR WALL AT LOCATION OF EXISTING 600 AMP SERVICE. GROUND ROD OPROVIDE MAXIMUM LENGTH AT 104" FOR 104" TAP RULE. NOTE IT IS NECESSARY TO USE GROUND SIZE INDICATED ABOVE TO COMPLY WITH M.E.C. 250.122) OCONTRACTOR SHALL PROVIDE OWNER WITH ADD ALTERNATIVE FOR TRANSIENT VOLTAGE SURGE SUPPRESORS TO PROTECT EACH OF THESE. Q2cJ iTEcTu PA.L coNSu�TiNG ENG�NEE�.�NG. INC. A. C.E. ELECTRICAL ENGINEER 517 SPRING VALLEY ROAD ALTAMONTE SPRINGS, FL 32714 PHONE: (407) 339 - 3060 FAX: (407) 339 - 8121 E-MAIL: gsigleQace-mepxom GREG SIDLE, P.E. P.E. LICENSE NO: 48671 EBN # 8019/# 9682 000PYRIOHT ARCHITECTURAL CONSULTINOENOWERM, INC. ALL RIGHTS RESERVED. SEAL: CLIENT: uw G E PROJECT: PANELBOARD SCHEDULES NOT TO SCALE 1wial ��� . DAl F DESCRIPTION ht's 0104 i s 40 All) CrWIA33 SNV'd 301AA0 ELECTRICAL LOAD SUMMARY -SVC. #3 NOV. 8, 2005 N. E C N.EC N.E. C SCALE: CONNECTED DEMAND DEMAND DESCRIPTION: KW FACTOR KW 1. EXISTING MOTOR CONTROL CENTER'MCC 1' 28.8 1.0 28.8 2. NEW 'MCC4' WITH (4) 15HP MOTORS 90.1 1.25 112.6 TOTAL = 118.9 TOTAL = 141.4 N.E.C. DEMAND KVA x 1000 = MINIMUM FEEDER AMPERAGE SYSTEM VOLTAGE x SQ.RT(3) 141.4 x 1000= 393.0 AMPS 208 x 1.73 THEREFORE, 400 AMPS IS ADEQUATE FOR'MCC4'. JOB NUMBER: 25763 DATE: NOV. 8, 2005 CAD FILE N 0 : 25763-EO01 SCALE: AS NOTED DRAWN: K, SIGLE CHECKED: G. SIGLE SHEET TITLE: SYMBOLS, GENERAL NOTES, ELECTRICAL SPECIFICATIONS, POWER ONE -LINE DIAGRAM, PANELBOARD SCHEDULES, AND ELEC LOAD SUMM. SHEET NO: SHEET . OF E-1