HomeMy WebLinkAbout150 Hazel BlvdPermit #
Job Address: AQ
Description of Work:
Historic District:
r L-�
CITY OF SANFORD PERMIT APPLICATION /�
Date: 1-6 -Zoo y
Zoning: Value of Work:
Permit Type: Building lz�_ Electrical Cl Mechanical Plumbing Fire Sprinkler/Alarm Pool
Electrical: New Service -# of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential 1---Non-Residential
fANon-Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Commercial
Occupancy Type: Residential 1-� Commercial Industrial Total Square Footage:
Construction Type: — I # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X)
Parcel #: �' Cn 51% ClnWy �_J`/ v (Attach Proof of Ownership &Legal Description)
Owners Name & Address: k, ckAid + ' -ki c 44; 5,.-2
/ t Phone: 7C� 13d 3 51ST 4/
Contractor Name & Address:rJ
. 0�5_
?^ -7 State License Number: rt r�'/
Phone & Fax:7y� ? )O iia 3 S Contact Person: L��CV HI a�-e Phone:? b f 10'/�T '7 I
Bonding Company:
Address:
Mortgage 4ender S : p
Address: 6,
1�-^ o / 11'' t�
Architect/Engineer: 1 C H V i Cif ' n eei's Phone: TQ% /• -7 '2
Address: �vro 5 6 Z�� Fax: Ka 7 -
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be clone in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements ofthis permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
AcceptanceZofper it is • if - do that I will notify the owner ofthe property ofthe requirem is of ida Lien Law, FS 713.
-�O e of weer/Ag nt Date ignature/o Contractor/Agent Date
Lu L �� G t
Prin Owner Agent' a i Print ntra or/Age is N e
'L
,CRY Pte�,� Tnl
MzW
tar. -State of Florida Date Sig ure of Not -Staf of Florida �,d�arfi
1,2007 ro;•••,�•o TONYAS� RNM
IF.cS et Notary * MY COMMISSION # DD 222598
* � n Services
hru ead9 E=XPIRES. July 11, 2007
�TEOFF`° Owner/Agent is _Personally Known to Me or Contractor/Agent is Personally Known to t§0 BondedThtu Budiiel NOtaty Service!
Produced ID Produced ID
APPLICATION APPROVED BY: Bldg1 L ~0 Zoning:
�/
(Initial & Date) (Initial & Date)
Special Conditions:
Utilities:
FD:
(initial & Date) (Initial & Date)
EXISTING SHINGLED ROOF
EXISTING HURRICANE CLIP
EXISTING FASCIA 4 50FFIT-- -
dol pll AFIF.-HDR. HT EX15TING STUCCO FIN16H-_-
NEW STUCCO FINISH TO MATCH EXIST.
RES. (OVER METAL LATH 4
VAPOR BARRIER)
NEW 1/2" PLYWD, SHEATHING -
NEW STUCCO FINISH TO MATCH EXIST.
RES. (OVER METAL LATH 4
VAPOR BARRIER) --- - mm - --
EXISTING GONG, DRIVE ---.
EXISTING SHINGLED ROOF
EXISTING HURRICANE CLIP
EXISTING FASCIA 4 5OFFIT
AFF. HDR HT. EXISTING STUCCO FIN15H
NEW STUCCO FINISH TO MATCH EXIST.
RES.,(OVER METAL LATH 4
VAPOR BARRIER
NEW SINGLE HUNG WINDOW
NEW 1/2" PLYWD. SHEATHING— -
NEW STUCCO FINISH TO MATCH EXIST.
RE$, (OVER METAL LATH 4
VAPOR BARRIER)
EXISTING CONC. DRIVE-- -_
EXISTING TRUSSES
NEW R-30 INSULATION
04" AFF. CEL. HT.
"-EXI5TING 1/2" DRYWALL
-EX15T. GONG: TIE BEAN!
-- EXISTING CONC. LINTEL
-NEW P.T. IX4 PAINTED TRIM
- P.T. 2Xa Top PLATE W/
13LUE-HEAD11 TAPCON ANCHORS
(4" MAX. FROM EA. END 4 24" O.C)
WOOD PANEL FIN15H
/_ NEW WOOD WINDOW SILL
—NEW PAINTED ua ,rRIM
k -----NEW WOOD PANEL FINISH
--- S" BATT. IN54. (R-30)
.--- EXISTING SLAB
`--NEW CONT. 2Xa P.T. PLATE
NEW 2Xa 5TUD5 0 2411 O.C. IN EXIST. OPENING UJ/
W/ SIMPSON (2) 55P STUDS TO PLATE "BLUE -HEAD" TAPCON ANCHORS
(4) IOd X 111/2 NAILS TO STUD d (4'I MAX. FROM EA. END 4 2411 O.C)
(1) IOd X 111/2 NAILS TO PLATE (TYP.)
T�P, WALL SECTION THRU WINDOW
�- EXISTING TRUSSES
NEW R-30 INSULATION
+8'-0" AFF. CEIL. HT.
"�-EXISTING 1/2" [DRYWALL
EXIST. CONC. `CIE F3EAM
— EXISTING CONC. LINTEL
--NEW P.T. IX4 PAINTED TRIM
P.T. 2Xa TOP PLATE W/
"BLUE -HEAD" TAPCON ANCHM
(4" MAX. FROM EA. END 4 24" O,C)
WOOD PANEL FINISH
5LOCKING AS REa.'D
---NEW WOOD PANEL FINISH
--a" BATT. IN5UL. (R-30)
.- --- EXISTING SLAB
\----NEW CONT. 2Xa P.T. PLATE
NEW 2Xa 5TUD5 0 2411 O.C. IN EXIST, OPENING W/
W/ 51MP50N (2) SSP STUDS TO PLATE 11BLUE-HEAD" TAPCON ANCHORS
(4) IOd X 11112 NAILS TO STUD $ (4" MAX FROM EA. END 4 24" O.C)
(1) IOd X 11112 NAILS TO PLATE (TYP.)
e•
G =rrFl. UJA- LL 5 T 10 1 TH U W,4LL
-
SCALE: 3/411 11-011
SCALE: 3/4" : I'-011
t1BLUE-HEAD11 TAPCON ANCHOR5
(4'I MAX. FROM EA, END 4 24" O.C) TOP OF TIE BEAM
8 PRE -CAST, REINF. CONC. HDR
r
I
I
I
CONC. FILLED, RE INF. CELL -I--- 5/811 PLYWOOD SHEATHING
I ON EA. SIDE OF BLOCKING
I —
I
I
I
I
i--
-- FROM P.T. 2X8 INSIDE OF OPENING
"BLUE-HEAD11 TAPCON ANCHORS I (TYP)
(411 MAX. FROM EA. END 4 24" O.C.) 1
I
I__
I
I FROM P.T. 2X8 INSIDE OF OPENING
I (TYP.)
I
I
GARAGE FLOOR I W _
I I
1 �
EX15T. GARAGE
OPENING DETAIL
,a -1 5CALE: 1/2" - 11-0"
+6-0" AFF. REAR, HT.
NEW STUCCO FINISH
TO MATCH EXIST. RES.
-
NEW NEW
01.011 FIN, FLR. I .:. °.� 4640 SW.�: .. .. � 440 6H.' • . .. • , 1
I .+24.1/-2(o.9 +24.7/-26.9
GRADE
i
I
1KJ 1-011
(EXISTING GARAGE PIR OPENING)
hLLV/AT10N
SCALE: 1/4" = 1'-011
0X121 INU UAKAUI:t
FLOOR PLAN
SCALE: 1/4" = 11-0"
NAILING PATTERN FOR SHEATHING:
4" O.C. 5HORT 50E, ad
(0" O.G. LONG 51DE, ad
12" O.C. FIELD, ad
FOR ROOF SHEATHING:
(0 " O.C., ad
SECTION 1600 DESIGN DATA'
Basic Wind Speed ( z4o m.p.h.
Wind Importance Factor
Building Category
Wind Exposure 13
Internal Pressure COtEF. 0.
15
Design Wind Pressure Zq.s P.S.F.
THIS STRUCTURE* HAS BEEN PESIGNED AS AN ENCLOSED STRUCTURE
IN ACCORDANCE WITH THE: REQUIREMENT'S OF SECTION !more, 2001
EDITION OF THE: FLORIDA BUILDING CODE AND, AS SUCH, WILL UJITH-
STAND 120 MPH WINDS (3-5ECOND GUSTS AT FACTOR 1, EXPOSURE 1/3.)
INTERNAL PRESSURE COEFFICIENT IS 0.18 FOR ENCLOSED STRUCTURE.
MINIMUM DESIGN PRESSURE FOR OPENINGS IS NOTED ON PLANS. CON-
NECTIONS HAVE BEEN CALCULATED TO SUPPORT APPLICA5LE LOADS.
ELECTRICAL
SYMBOLS
110 OUTLET
220 OUTLET
WEATHER PROOF
�} 110 OUTLET
HALF NOT
r,® DISCONNECT
- CEILING MOUNTED PLANS REVIE I -
_c WALL MOUNTED CITY OF SANFOR
-¢- REGCES�ED A
FAN
c PLOURE�CENT L
FRAC LIGHT
EXHAU$T PAN
EXHAUST .FAN
uutlrr AND LI%T
„ HEAT LAMP
P05T LAMP
PULL CHAIN
TELEVINON
PHONE
FLOOD LIGHT
pI� 105Al_
GARB� E
51NOLE
THREE WAY
FOUR WAY
DIMMER
p
llRllEIEW AY
GLIM
TOGGLE
CHIME
I PU5H BUTTON
INTERCOM
M 655! HEADER TYPE
-- -HEADER TYPE_
G DL. NO,
DESC- P ON
A
(2) 2 X,h HDR, UJ% 1/2" i5CT 0(715 FLITCH
B
(2) 2 X S HC?R, UJ/ 112" PLY OD FLITCHT
C
(2) 2,X 10 H W/ 1/2t1YWOO ISN _
D
(2) 2 X 12 HDR:. W/ `1 " PLYU OOD FL ITCH
E
PRE - ENGINEE j3Y `C�RU55 Co.
F
PRECAST GONC, LINTEL W/(1) W FILLIED 4
BOND BEAM ABOVE W/(I) OE, PAR FILLED
G
PRECAST CONC. U -LINTEL .ILL I.D UJ/
DOND BEAM AE30VE W/(U #5 E3AR, FILLED
H
PRECAST GONG. U -LINTEL IN POND IBEAM
FILLED W/ (2) 15 5AR6_
J
PRECAST CONC, LINTEL UJ/(2) 05 FILLED, 4
!BOND BEAM ABOVE W/(2) #a FILLED
EX16TING PRECAST CONC. LINTEL
W1 EX15T. BOND REAM ABOVE
NOTE: ALL PRIECAST LINTELS TO 13E RATED UJ/ A MIN.
RATING AS SPECIFIED ON THESE DRAWINGS, REFER TO
SPECIFICATIONS ON STRUCTURAL DRAWINGS.
LEGTEEND:
EX15T. 5L C)CK WALL.
NEW FR/AME WALL,
(NON -LOAD FImARING)
WOOD FOR 5TRUCTURAL CONDITION5 TO 5
GROUP II 6PECIE6 OR MINIMUM fb=EI300 x'.5.1.
■ �
ANP
y.
STRUCTURALLY. ADEQUATE FOR 120. M.P.1-I. WIND$, 11/14/o
3
TH15 DRAWING MEETS THE
REQUIREMENTS SET FORTH A N0T
IN CHAPTER 16 OF THE f RAU)INCx'No.
FLORIDA BUILDING COPE G 11 -114
2001 EDITION AS PUBLISHED ��ar SNE)=T NO,
BY THE STATE OF FLORIDA AND
ENFORCED BY THE LOCAL �z
JURISDICTION. A 1
COPYRIGHT- 2009, LANE TRAUJICK, C.P:l 3.D./ A.I.D.D. OP 6HEETS