Loading...
HomeMy WebLinkAbout2540 Jewett Ln (2)CITY OF SANFORf) RF1 :N11T'APPLICATION 6 _0 .lob Address: _�. � _� — .�! __� __ .�Z�f Description of Work: flistorie DistritL' Zoning: _ Value of Work: $_�J/t_�i�� — Permit Type: Building — Electrical Mechanieal _.­ Plumbing Fite Sprinkler/Alarm Pool Electrical: New Service — N of AMPS C)O Addition/Alteration Change of Service �><_ felrporai'y Vole 0 /,`J06' Mechanical: Residential Non-Kesidential __ Replacement , New (Duct Layout & Vnergy Calc. Required) Plumbing/ New Conunercial: # of Fixtures It of Water & Sewcr Lines It of Gas Lines _T— Plumbing/New Residential: 9 of Water Closets �. Plnmbing Repair -- Residential or. Commercial occupancyType: Residential Commercial _ lndustrial�Total Square Footage: Construction Type: Hof Stories: It of Dwelling Units: Mood lone: (1, EMA form required for other than \) Parcel It: __.T Owners Name & Address: (Attach Proof of Ownership & Legal Description) Contractor Narne & Addresss:. / g c� State License Number: Phone & Fax: i _ — ContactYhone:��_-� Bonding Company: Address: _,_ Mortgage Lender: Address:-- ArchitecUEngineer..��7��'% Address: /e��l�iC�f C'�_�T �f� r� G' —��o /s Fax: Application is hereby made to obtain a permit to do the work and installations as indicated_ l certify hat no work or installation has Colorncnced prior to the issuance of a pemtitmj�rd [tat all�verk will tae perftinSicd to meet standards of all laws icgulating construction in this jurisdiction. 1 rmderstand that a separate perruit ust be secutyd for E•LECTRIC:AL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEA -1 EKS, TANKS, and AIR CON DrrION GKS`; OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO.OWNER-.-YQU• FAILURE TO RECOKD A NOTICE OF COMM ENCENIF.NT MAY RESULT IN YOUR PAYING TWICE FOR tMPROVEMEI Sr10 YOUR PROPERTY elf yOU INTEND TO OBTAIN FINANCING, CONSUL'1' WITH YOUK I -ENDER OR AN ATI-OKNEY 13EFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addi,I to the requirements of this pennit, there may b this comity, anct jIhcre ntay be additional permits required from other Acccptance Vfpennit is verification that I will notify the owner of tfre iguature of-Owner/Agent Owner/Agent's Name gnature of Notaty•State of I=loiida is Personally Known to Nle ID .y Date APPLICATION APPROVED BY-- Bldg. (initial & Date) Special Conditions' I restrictions applicable to this property that may be found in the public records of ttal entities such as water management districts, state agcncics, or federal agencies_ of tl(fuil 11 7 of Flo '(fit Licit Lar /S :M3 t nann nPCnnt(clor/APC It Date JJ , 's Name Sigratute of Notuiy-Slate of Florida Date 1 DEBBIE f31 A11TON my co ° ''+irtN it I70 16;J491 Comtructor/Agcrari rs_�Pcrsoil;thY'K.trdtKu,txt.Mcc,t.:n/ _ Produecd ID. (initial & Date) Utilities: _ FD: _..-- (Initial & Date) (Initial & Date) �O g S, .��. ALUMINUM ACCESS HAT W LACKSET AND RECESSED HANDLE (SEE NOTE 8) r FLANGED RISER W/ BLIND FLANGE ALUMINUM ACCESS HATCH 4YVITD.I. NEN NTVECAP LCCKSET & RECESSED HANDLE 12" STANDARD FLANGED TEE e" 2" 6 3l ELEV. Y Ol>II� ti.. ; y EXIST, GRADE CONC• !th•��'. , %1. • . . S.'r. nr '. • '• '• r' :�`'n /f�%�. �:{ \ :=t.C., �iJl�%: , r`.� `�`.tirr�iil`�4t ?. !! ::.4,.�?��A.'a �;�ir .�� .�' T77.1{ n t7�• .�Z 2w E4Elt YALYE M� tOI�IIATGi! 8"X4"REDUCER ,: 712wMIN 4 ; ; STANIM SILO. ttIMR31IIME PJAQE W. POWER CABLE O.C.E.W.: !ET CM VALVE nfl- a 5iA11' E PIPS A.DIM 2-04 310 STAINLESS STEEL ORIPEYE FORCE MAIN 4" CHECK VALVE ^ r PVC LIFTING CABLE WITH 12" 316 I }- i ',' T7" STAINLESS STEEL CHAIN .T L AR� rW VALVE PVC PIPE 3" R DRAIN, SLAPE LI�TENET PIPE 1 LESS Sl L I �T WITH ION PIPE •LAPPER - �, 11ATUM EL.E1/. 0.00 (S► LLMI)® tD !V. x�E'�xr" tXtAT� ALAII#1 Q ELEV. Z Xp 9� _.- ELEV. W.1 W uu LwUro R LEV � Lm Nw ..ON& ELEV. V On �. " C • FINS 99 .t - GROELEV. T AT Com. •: GRAVEL 3" *8-12 O.C. E.W. MIN� 3/4 DIA. x 11" STAIN STI:E6 ANCHOR BCL(:. TO D 7" INTO BASE. PUMP STATION DETAILS PLANS, SECTION, AND NOTES WET WELL AND VALVE VAULT LINER THICKNESS INCHES a" THICK MANUFACTURER DIAMETER (INCHES) HEIGHT (FEET) 3-8 7-12 113-20121-25126-35 60 01M s 1 1 X CONCRETE PAD 1O $Cala: N.T.S. DIM D 11.5 ® DATUM M. 0.00 (SEA LEVEL) DIM E NOTE 8 PER CPH REVIEW J.E.M. DIM F NOTE 8 ALL EXPOSED METAL SHALL BE PRINTED WITH 2 COATS OF EXTERIOR DIM G 4.25" BE SLEEVE TYPE. DIM H CAPPED NIPPLE AND VALVE WITH STAINLESS 10. DIM J 2. DIM K 4!-6 MANUFACTURER: FLYGT X A.BS MODEL: CP3102 IMP: 435 DIA: ; MM, SPEED: 1700 RPM; DISCHARGE SIZE: � 4 � IN.; VOLTAGE: 230 ; 2'MIH. VALVE VAULT I I STEEL 011 -FILLED PRESSURE GAUGE AND. OUT. (TWO COATS, 9 MILS EACH.) � � -5.10 ED U 3 H.P.: 5 I ELEV V b ELEV W ELEV X ELEV Y VALVE VAULT SHALT. BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE PIPE 15.00 ELEV Z ANTENNA -0.70 'AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER 12. OPERATING CONDITIONS: SERVICE DISCONNECT PIPE SIZES UFLOORDRAIN �, METIER FPLALARM LIGHT P1011 MGgALL I --r MiAX 0 122114-11 PAHMN K4010WAN SPA,,, is WORM Sim 9COND DrAm IN CONCItm 3/�4" CONDUIT OUTLINE OF ACCESS PLUG VALVE RTU ANTENNA & ELLYAMN (OPENING CARL£ HOLDERCOUPLINGS CHECK VALVE EMERGENCY PUMPrJ� CONNECTION ..+�-A METER BASE 3" CONDUIT MA5LARq 1A I.ATION �TYP.) N.T.S. TO SIMM �Y�AID" FLOAT WT.S. * VALVE �X SHALL BE ENLARGED TO POINT 2. WHEN TWO (2) SEPARATE CONDUCTOR -TYPE MOTORS ARE USED, CONDUIT PLAN VIEW to ACCOMODATE FLAW METER OR MARM S Ut,/HOWfM V, 3 PH, 60 HZ. PER NOTE 4 TO 3 INCHES. N.T.S. S. wn Vm 1 mm DAK Ar<Aldi LwRr SERVICE ENTRANCE__RISO PUMP STATION CONTROL PANEL RADIO r BE 3 PHASE FROM A 3 PHASE SOURCE ONLY. TELEMETRY AND MONITORYING SYSTEM s T "Oo a MURMD i I � Nd,S. INSTALLATION DETAIL n�ac 0=0 s w►tT. TAM= MSR MM RM SLWAY 1 I TRui GENERATOR PLUG COMPATIBLE FOR LIFT STATION. . p/�llq, II ALUMINUM ACCESS HAT W LACKSET AND RECESSED HANDLE (SEE NOTE 8) r FLANGED RISER W/ BLIND FLANGE ALUMINUM ACCESS HATCH 4YVITD.I. NEN NTVECAP LCCKSET & RECESSED HANDLE 12" STANDARD FLANGED TEE e" 2" 6 3l ELEV. Y Ol>II� ti.. ; y EXIST, GRADE CONC• !th•��'. , %1. • . . S.'r. nr '. • '• '• r' :�`'n /f�%�. �:{ \ :=t.C., �iJl�%: , r`.� `�`.tirr�iil`�4t ?. !! ::.4,.�?��A.'a �;�ir .�� .�' T77.1{ n t7�• .�Z 2w E4Elt YALYE M� tOI�IIATGi! 8"X4"REDUCER ,: 712wMIN 4 ; ; STANIM SILO. ttIMR31IIME PJAQE W. POWER CABLE O.C.E.W.: !ET CM VALVE nfl- a 5iA11' E PIPS A.DIM 2-04 310 STAINLESS STEEL ORIPEYE FORCE MAIN 4" CHECK VALVE ^ r PVC LIFTING CABLE WITH 12" 316 I }- i ',' T7" STAINLESS STEEL CHAIN .T L AR� rW VALVE PVC PIPE 3" R DRAIN, SLAPE LI�TENET PIPE 1 LESS Sl L I �T WITH ION PIPE •LAPPER - �, 11ATUM EL.E1/. 0.00 (S► LLMI)® tD !V. x�E'�xr" tXtAT� ALAII#1 Q ELEV. Z Xp 9� _.- ELEV. W.1 W uu LwUro R LEV � Lm Nw ..ON& ELEV. V On �. " C • FINS 99 .t - GROELEV. T AT Com. •: GRAVEL 3" *8-12 O.C. E.W. MIN� 3/4 DIA. x 11" STAIN STI:E6 ANCHOR BCL(:. TO D 7" INTO BASE. PUMP STATION DETAILS PLANS, SECTION, AND NOTES WET WELL AND VALVE VAULT LINER THICKNESS INCHES MATERIAL MANUFACTURER DIAMETER (INCHES) HEIGHT (FEET) 3-8 7-12 113-20121-25126-35 60 01M s 1 1 X DIM C 1O $Cala: N.T.S. DIM D PUMPING STATIONS DIMENSIONS ELEV, AT CONST. DIM A 1 7 01M s 1 6' -CI* 1 No. Date DIM C 1O $Cala: N.T.S. DIM D 11.5 ® DATUM M. 0.00 (SEA LEVEL) DIM E NOTE 8 PER CPH REVIEW J.E.M. DIM F NOTE 8 ALL EXPOSED METAL SHALL BE PRINTED WITH 2 COATS OF EXTERIOR DIM G 4.25" BE SLEEVE TYPE. DIM H 8'-0" 10. DIM J 2. DIM K 4!-6 MANUFACTURER: FLYGT X A.BS MODEL: CP3102 IMP: 435 DIA: ; MM, SPEED: 1700 RPM; DISCHARGE SIZE: � 4 � IN.; VOLTAGE: 230 ; ELEV T AND. OUT. (TWO COATS, 9 MILS EACH.) � � -5.10 ED U 3 H.P.: 5 --3.60 ELEV V -2.10 ELEV W ELEV X ELEV Y VALVE VAULT SHALT. BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE PIPE 15.00 ELEV Z UK movom -0.70 'AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER 12. OPERATING CONDITIONS: ����� .• «; . . . . . �� II POINT GPM TDH FEET 5. VALVE VAULT SHALL HAVE SEALED FLOOR AND DRAIN. MIN. 0.0 57 6. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL. OR VALVE D.O.C. 185 44 VAULT SHALL BE MADE WATERTIGHT WITH WALL SLEEVE OR M1550 NON -SHRINK GROUT.13. WET WELLAND VALVE VAULT SHALL HAVE AN INTEGRAL INTERIOR LINER .. 7. THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN AS SPECIFIED IN SECTION 46.2 OF THE UTILITIES MANUAL. WET WELL 14. A GENERATOR SET OR PRO RATA FUNDING SHALL BE REQUIRED 1N 8. WET WELL AND VALVE VAULT COVERS SHALL BE ALUMINUM WITH 304 S.S.. ACCORDANCE WITH SECTION 46.6.OF THE UTILITIES MANUAL. HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP MANUFACTURER,. WITH A MINIMUM SIZE OF 48 INCHES BY 48 INCHES. r+ l n t PER PUMP MWACtUM REQUIRl W 1 No. Date 100 YEAR FLOOD ELEVATION= 9AW Revision Approved Designed by: N.D.E. 10104 $Cala: N.T.S. Q 1118/04 PER CITY OF SANFORD COMMENTS J.E.M. ® DATUM M. 0.00 (SEA LEVEL) GENERAL NOTES: ® 11/28104 PER CPH REVIEW J.E.M. Checked by: M.D.S. 11 10/04 1. ALL EXPOSED METAL SHALL BE PRINTED WITH 2 COATS OF EXTERIOR 9. FLEXIBLE COUPLING SHALL BE SLEEVE TYPE. n W ENAMEL PAINT. 10. PUMPS SHALL BE: 2. WET WELL. AND VALVE VAULT SHALL BE COATED WITH COAL TAR INSIDE � MANUFACTURER: FLYGT X A.BS MODEL: CP3102 IMP: 435 DIA: ; MM, SPEED: 1700 RPM; DISCHARGE SIZE: � 4 � IN.; VOLTAGE: 230 ; AND. OUT. (TWO COATS, 9 MILS EACH.) � � HZ.: 60 PHASE: 3 H.P.: 5 �.eONWV pm BASE AND FIRST RISER UNIT TO BE CAST MONOLITHIC. MIN. SOLID SIZE: IN.; CURVE: SEE ATTACHMENT, 4. VALVE VAULT SHALT. BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE PIPE 11. ALL HARDWARE IN WET WELL -AND VALVE BOX TO BE STAINLESS STEEL. UK movom SPINDLES WITH MINIMUM CLEARANCES AS SHOWN FOR 6" DIAMETER 'AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER 12. OPERATING CONDITIONS: PIPE SIZES lit 11COilM P1011 MGgALL K4010WAN SPA,,, is WORM Sim DrAm IN CONCItm Mrona NOTES: RTU ANTENNA & ELLYAMN 1. METER BASE MAY BE REVERSED IF REQUIRED BY POWER COMPANY. MA5LARq 1A I.ATION N.T.S. WT.S. 2. WHEN TWO (2) SEPARATE CONDUCTOR -TYPE MOTORS ARE USED, CONDUIT SHALL BE INCREASED TO 3 INCHES. S. POWER SUPPLY SHALL BE UNDERGROUNDON THE LIFT STATION SITE PUMP STATION CONTROL PANEL RADIO AND SHALL BE 3 PHASE FROM A 3 PHASE SOURCE ONLY. TELEMETRY AND MONITORYING SYSTEM INSTALLATION DETAIL 4. TO INCLUDE GENERATOR PLUG COMPATIBLE FOR LIFT STATION. POINT GPM TDH FEET 5. VALVE VAULT SHALL HAVE SEALED FLOOR AND DRAIN. MIN. 0.0 57 6. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL. OR VALVE D.O.C. 185 44 VAULT SHALL BE MADE WATERTIGHT WITH WALL SLEEVE OR M1550 NON -SHRINK GROUT.13. WET WELLAND VALVE VAULT SHALL HAVE AN INTEGRAL INTERIOR LINER .. 7. THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN AS SPECIFIED IN SECTION 46.2 OF THE UTILITIES MANUAL. WET WELL 14. A GENERATOR SET OR PRO RATA FUNDING SHALL BE REQUIRED 1N 8. WET WELL AND VALVE VAULT COVERS SHALL BE ALUMINUM WITH 304 S.S.. ACCORDANCE WITH SECTION 46.6.OF THE UTILITIES MANUAL. HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP MANUFACTURER,. WITH A MINIMUM SIZE OF 48 INCHES BY 48 INCHES. r+ l n t PER PUMP MWACtUM REQUIRl W 1 No. Date 100 YEAR FLOOD ELEVATION= 9AW Revision Approved Designed by: N.D.E. 10104 $Cala: N.T.S. Q 1118/04 PER CITY OF SANFORD COMMENTS J.E.M. ® DATUM M. 0.00 (SEA LEVEL) GENERAL NOTES: ® 11/28104 PER CPH REVIEW J.E.M. Checked by: M.D.S. 11 10/04 1. ALL EXPOSED METAL SHALL BE PRINTED WITH 2 COATS OF EXTERIOR 9. FLEXIBLE COUPLING SHALL BE SLEEVE TYPE. n W ENAMEL PAINT. 10. PUMPS SHALL BE: 2. WET WELL. AND VALVE VAULT SHALL BE COATED WITH COAL TAR INSIDE � MANUFACTURER: FLYGT X A.BS MODEL: CP3102 IMP: 435 DIA: ; MM, SPEED: 1700 RPM; DISCHARGE SIZE: � 4 � IN.; VOLTAGE: 230 ; AND. OUT. (TWO COATS, 9 MILS EACH.) � � HZ.: 60 PHASE: 3 H.P.: 5 3. BASE AND FIRST RISER UNIT TO BE CAST MONOLITHIC. MIN. SOLID SIZE: IN.; CURVE: SEE ATTACHMENT, 4. VALVE VAULT SHALT. BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE PIPE 11. ALL HARDWARE IN WET WELL -AND VALVE BOX TO BE STAINLESS STEEL. SPINDLES WITH MINIMUM CLEARANCES AS SHOWN FOR 6" DIAMETER 'AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER 12. OPERATING CONDITIONS: PIPE SIZES POINT GPM TDH FEET 5. VALVE VAULT SHALL HAVE SEALED FLOOR AND DRAIN. MIN. 0.0 57 6. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL. OR VALVE D.O.C. 185 44 VAULT SHALL BE MADE WATERTIGHT WITH WALL SLEEVE OR M1550 NON -SHRINK GROUT.13. WET WELLAND VALVE VAULT SHALL HAVE AN INTEGRAL INTERIOR LINER .. 7. THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN AS SPECIFIED IN SECTION 46.2 OF THE UTILITIES MANUAL. WET WELL 14. A GENERATOR SET OR PRO RATA FUNDING SHALL BE REQUIRED 1N 8. WET WELL AND VALVE VAULT COVERS SHALL BE ALUMINUM WITH 304 S.S.. ACCORDANCE WITH SECTION 46.6.OF THE UTILITIES MANUAL. HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP MANUFACTURER,. WITH A MINIMUM SIZE OF 48 INCHES BY 48 INCHES. r+ l n a 1 No. Date R.evislon Approved No. Date Revision Approved Designed by: N.D.E. 10104 $Cala: N.T.S. Q 1118/04 PER CITY OF SANFORD COMMENTS J.E.M. Drawn by: M.W.K. 10104 ® 11/28104 PER CPH REVIEW J.E.M. Checked by: M.D.S. 11 10/04 Date, OCTOBER 2004 3 Approved by: J,E.M. 10104 Job No. 511601 n W ® CerifftcateofAuthorlxatlonNo. 3215 File: LIFTSTA MAKE: - - - MODEL: ONE (1)LB. SINGLE AXLE TRAILER TO INCLUDE THE FOLLOWING: HYDRAULIC BRAKES ICC LIGHTING FENDERS BALL COUPLER COMMERCIAL TIRES -- HWY. RATED FRONT JACK STAND REAR STABILAZER JACKS GALLON FUEL TANK FUEL LEVEL GAUGE FILL/VENT CAP FUEL SUPPLY PORT FUEL RETURN PORT ELECTRICAL PACKAGE TO INCLUDE: (1) ---AMP LOAD CENTER 50 FEET OF 2/OT REQUIRED CABLE '(1)_ --.AMP PLUG - START UP AND ONSITE TESTING STARTUP NOT TO EXCEED 4 HOURS OPERATIONAL TRAINING NOT TO EXCEED 4HOURS CELERY ESTATES NORTH SANFORD, FLORIDA 5. RADIO TELEMETRY IAND MONITORING SYSTEM TO CITY OF SANFORD SPECIFICATIONS. 6, PIPE MOUNTED ALARM LIGHT SHALL BE INGRAM LRX-40 (RED) 120 VAC OR EQUAL. 7. A STREET LIGHT SHALL BE POSITIONED IN THE RIGHT-OF-WAY LEFT OF THE STATIONS DRIVEWAY, e. A WEATHERPROOF LOCKABLE ELECTRICAL OUTLET OUTSIDE OE THE CON- TROL PNEL SHALL BE INSTALLED. 9.. RTU, CONTROL AND SERVICE DISCONNECT PANEL BOXES SHALL 6L OF STAINLESS STEEL. 10. LIFT STATION SHALL HAVE (2) PUMPS. GENERATOR SET PHASE: , 3 , . HERTZ: 60 VOLTS . _ WIRE: 4 RATED KW STANDBY KVA RPM ENCLOSED ACCESSORIES: WEATHER PROTECTIVE HOUSING MOUNTED SILENCER MOUNTING KIT CRITICAL SILENCER COOLING SYSTEM: BLOCK HEATER 120 VOLT 1500 WATTS UNIT MOUNTED RADIATOR 40 DEG. C FUEL SYSTEM: FLEX FUEL LINES BASE TANK GAL. SINGLE WALL, INTEGRAL, IN TRAILER CIRCUIT BREAKER/ACCESSORIES ,_.-.-,,.AMP. U.I. ...VOLT CIRCUIT BREAKER CONTROLLER/INSTRUMENT PANEL AC AMMETER, VOLTMETER, 2-1/2",'2% AC FREQ. METER 2-1211, 5;4 AW/VW SELECTOR SWITCH, 7 POSITION `. PANEL ILLUMINATION LIGHTS, AUDIBLE ALARM WITH SILENCE SWITCH VOLTAGE ADJUSTMENT POTENTIOMETER OIL PRESSURE, WATER TEMP. GAUGE, RUNNING TIME METER, DC VOLTMETER AUTOMATIC SENSING CONTROLS, COOL DOWN TIMER CYCLE CRANKING,, OVERVOLTAGE SENSING Engtnrcra Mho1'Ianners Landscape Architects Surveyors Coustruction Management www.cphengrneera.cam Wo West &?too 5tra4 Sanfor4 FL 32771 .RO, I9ox200, Sanfor4 FL 32i rhonc107.311. U1 T=407.330.0639 ES E. MCMULL.AN, P.E, 8018.0 SAFETY SHUTDOWN, INDICATING LIGHTS AND ALARMS FOR THE FOLLOWING: LOW OIL PRESSURE OVERSPEED OVERCRANK HIGH ENGINE TEMPERATURE AUXILLIARY/LOW WATER LEVEL/OVERVOLTAGE ELECTRICAL ACCESSORIES: STARTING BATTERY/8ATTERIES 12 VOLT BATTERY RACK AND CABLES VOLTAGE REGULATOR 2% CHARGER TRICKLE 2 AMP. ADDITIONAL ACCESSORIES: ISOLATORS SKID END CAPS WARRANTY 1 YEAR OIL DRAIN LINE O/M MANUALS 3 SETS 50 FOOT 2/OT POWER CABLE WITH MALE CONNECTOR TRAILER TO D.O.T. STANDARDS OIL INITIAL FULL ANTI --FREEZE INITIAL FILL 50/50 PROPERTY APPRAISER ID NUMBERS: 29.19.31-300.013A-0000, 29-1&300.4140-0000, 29-19-31-300.0150-U 000 SEMINOLE COUNTY APPROVED FOR CONSTRUCTION THIS APPROVAL IS SUBJECT TO SPECIFIC CONFORMANCE TO THE SEMINOLE COUNTY LAND DEVELOPMENT CODE AND ANY SPECIAL REQUIREMENTS OF THE HOARD OF COUNTY COMMISSIONERS, IT SHALL„ BE THE RESPONSIBILITY OF THE DEVELOPER TO CORRECT ANY DEFECTS IN THE PLANS OR THE FACILITY AS CONSTRUCTED WHICH RESULTS IN A FAILURE TO MEET APPLICABLE CODE REQUIREMENTS, ADMINISTRATIVE ACCEPTANCE OF THE DEVELOPER'S PLANS DOES NOT CONSTITUTE A WAIVER OF ANY CODE REQUIREMENTS NOR DOES IT RELIEVE THE DEVELOPER OF RESPONSIBILITY TO MEET THOSE REQUIREMENTS. THIS SPECIFIC APPROVAL 18 VALID FOR A PERIOD OF ONE YEAR FROM THE DATE BELOW, APPROVED. SEMINOLE COUNTY DEVELOPMENT REVIEW DEPARTMENT DATE LIFT ST'AT'ION SHEET VOLTS. 480/211 PHASE: 30,4W BUS RATING, 4000 AMP EACH PHASE, DERATED NEUTRAL SINGLE PANEL: THREE SECTION GROUND BUS YES MOUNTING: FREE STANDING ON 4" HIGH HOUSEKEEPING PAD 480/277 30,4W 225A MLO YES YES SURFACE MAIN SWITCH BOARD 'MSB' LOADS LOADS LIGHTING SOURCE: ELECTRIC UTILITY KVA AMPS CONN. LOAD: 2,934.9 15320 DEMAND LOAD: 2,326.8 2,800 DESCRIPTION CKT NO. KVA A KVA B INA C AMPS/ POLE AMPS/ POLE KVA A KVA B KVA C CKT NO. DESCRIPTION AMPS/ POLE WA A 133.3 WA C CKT NO. 1 DESCRIPTION: 133.3 DEIONIZED WATER 1 2.1 20/3 PANEL'PPI-A' 1 REVERSE OSMOSIS SYSTEM 133.3 2 600/3 600/3 & 133.3 3 2 PANEL'PP1-R' ---- 0 25.0 SPARE 1333 PANELBOARD. -------- 0.2 ------- 133.3 VOLTS 2.1 ---- ---- El 100.0 25.0 6 0.72 -------- 100 0 SPACE ONLY 7 DRAWING NOTE MNT PANFL'PP2-A' 3 SPACE ONLY 100.0 8 450/3 450/3 SPACE ONLY 100.0 4 PANEL'PP2-B' 10 18.0 SPACE ONLY 10 100.0 -------- SPACE ONLY 11 100.0 ---- 12 13.3 12 13 0.72 3.3 13 T-1 (MACH CONTROL CABINI-T) 5 SPACE ONLY 13.3 15 60/3 15/3 SPACE ONLY 13 6 LOAD AUXILARY DRIVE 16 SPACE ONLY 16 13.3 SPACE ONLY SPACE ONLY 17 33 18 3.3 18 19 SPACE ONLY 114.7 19 UNLOAD AUXILARY DRIVE 7 SPACE ONLY 3.3 21 15/3 600/3 SPACE ONLY 114.7 8 PRIMARY BLOWER MOTOR (350 HP) 22 SPACE ONLY 22 3.3 SPACE ONLY SPACE ONLY 23 114.7 24 114.7 24 25 SPACE ONLY 26.6 25 BOOSTER BLOWER MOTOR (350 HP) 9 SPACE ONLY 114.7 27 600/3 200/3 SPACE ONLY 26.6 10 COOLING BLOWER (15 HP) 28 SPACE ONLY 28 114,7 SPACE ONLY SPACE ONLY 29 26.6 30 64.0 30 31 SPACE ONLY 38.8 31 COMPRESSOR (60 HP) 11 SPACE ONLY 64.0 33 175/3 225/3 SPACE ONLY 38.8 12 PANEL ' i' 34 SPACE ONLY 34 64.0 SPACE ONLY SPACE ONLY 35 38.8 36 66.5 36 37 SPACE ONLY 66.5 37 JUNCTION BOX 'JB -1' 13 SPACE ONLY 66.5 39 400/3 400/3 SPACE ONLY 66.5 14 JUNCTION BOX 'JB -2' 40 SPACE ONLY 40 66.5 SPACE ONLY SPACE ONLY 41 66.5 42 SUB TOTALS: 495.1 495.1 1495.1 SUB TOTALS. SPACE ONLY 1 1.64 1 483.2 483.2 918.3 918.3 4832 978.3 2,934.9 KVA CONNECTED NOTES: 1. WITH 3/3500 A MAIN DEVICE 100% RATED WITH SHUNT TRIP. 2. SERVICE ENTRANCE RATED. 3. GROUND FAULT PROTECTION MAIN. 4. 480YI277 VOLT, 3 PHASE, 4 WIRE, 60 HERTZ, 5. FREE STANDING, BOLTED SECTIONS, NEMA 1 ENCLOSURE. 6. FRONT ACCESSABLE ONLY. 7. 100K AIC MAIN DEVICE. 8. SERIES RATED DISTR/BUTUION SECTIONS 9. DESIGN BASED ON SQUARE -D 'QED' SWBA 10. PROVIDE MINIMUM OF FOUR (4) 40013 SPACES FOR FUTURE CONNECTIONS. 11. PROVIDE TVSS IN MAIN SECTION - SEE SPEC. VOLTS: PHASE: BUS RATING: SINGLE PANEL GROUND BUS: MOUNTING: 480/277 30,4W 225A MLO YES YES SURFACE SUB PANEL. '1' (SUB PNL 1) LOADS LIGHTING PANEL. '1' LOADS AUTHORITY HAVING JURISDICTION Q LOADS PANEL '1', CKT 2:4:6 KVA AMPS 10.92 30.3 0.0 0.0 DESCRIPTION: SOURCE: CONN. LOAD: DEMAND LOAD: MSB, CKT 12 WA AMPS 135.3 163.0 140.0 168.5 WA 8 DESCRIPTION CKT N0. KVA A KVA WA AMPSI B C POLE AMPS/ POLE WA A KVA B WA C CKT NO. 1 DESCRIPTION: AmiP DEIONIZED WATER 1 2.1 20/3 110/3 25.0 REVERSE OSMOSIS SYSTEM SPARE 2 DUPLEX RECEPTACLE. SUB PANEL '1' & ------- 3 2.0 2.1 ---- ---- 0 25.0 SPARE 4 PANELBOARD. -------- 0.2 ------- 5 VOLTS 2.1 ---- ---- El ------- 25.0 6 0.72 -------- KVA SPACE ONLY 7 DRAWING NOTE MNT 90/3 18.0 SPACE ONLY RECEPTACLE @ COL. 8 GLASS WATER SYSTEM 0.72 SPACE ONLY 9 ---- 10 18.0 SPACE ONLY 10 11 -------- SPACE ONLY 11 ---- 12 18.0 12 13 0.72 SPACE ONLY 13 14 SPACE ONLY 14 15 SPACE ONLY 0.72 SPACE ONLY 15 16 SPACE ONLY 16 17 SPACE ONLY SPACE ONLY 17 18 SPACE ONLY 18 19 SPACE ONLY SPACE ONLY 19 20 SPACE ONLY 20 21 SPACE ONLY SPACE ONLY 21 22 SPACE ONLY 22 23 SPACE ONLY SPACE ONLY 23 24 SPACE ONLY 24 25 SPACE ONLY SPACE ONLY 25 26 SPACE ONLY 26 27 SPACE ONLY SPACE ONLY 21 28 SPACE ONLY 28 29 SPACE ONLY SPACE ONLY 29 30 SPACE ONLY 30 31 SPACE ONLY SPACE ONLY 31 32 SPACE ONLY 32 33 SPACE ONLY SPACE ONLY 33 34 SPACE ONLY 34 35 SPACE ONLY SPACE ONLY 35 36 SPACE ONLY 36 37 SPACE ONLY SPACE ONLY 37 38 SPACE ONLY 38 39 SPACE ONLY SPACE ONLY 39 40 SPACE ONLY 40 41 SPACE ONLY SPACE ONLY 41 42 SPACE ONLY 42 SUB TOTALS. SPACE ONLY 1 1.64 1 1.64 SUB TOTALS. 2.1 2.1 2.1 2.0 3.64 43.0 45.1 1 43.6 1 45.1 430 45.1 135.3 KVA CONNECTED VOLTS: 2081120 PHASE: 30, 4W BUS RATING: 225A MCR SINGLE PANEL: YES GROUND BUS: YES MOUNTING: SURFACE DESCRIPTION: SUB PANEL. '1' (SUB PNL 1) LOADS LIGHTING LOADS AUTHORITY HAVING JURISDICTION Q SOURCE. CONN LOAD: DEMAND LOAD: PANEL '1', CKT 2:4:6 KVA AMPS 10.92 30.3 0.0 0.0 DESCRIPTION: CKT NO. KVA A WA 8 KVA C AMPS/ AMPS/ POLE POLE KVA A 1 KVA B KVA C CKT NO_ PENDANT MOUNTED LIGHT FIXTURE. DESCRIPTION: SHUNT TRIP OPERATOR 1 0.2 AmiP BATTERY OPERATED EMERGENCY LIGHT FIXTURE. 20/1 30/3 2.0 SINGLE POLE SWITCH. 48" AFF 2 REVERSE OSMOSIS SYSTEM SPARE 3 DUPLEX RECEPTACLE. 0.2 & 2011 ---- 18" AFF 2.0 SPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AS SHOWN 4 0 -------- SPARE 5 PANELBOARD. 6"-6' TO TOP 0.2 2011 1 6"-6' TO TOP VOLTS 2.0 6 El ------- RECEPTACLE @ COL 7 0.72 AS NOTED KVA 2011 0' DRAWING NOTE MNT 8 SPACE ONLY RECEPTACLE @ COL. 9 0.72 2011 10 SPACE ONLY RECEPTACLE @ COL. 11 0.72 2011 12 SPACE ONLY RECEPTACLE @ COL. 13 0.72 2011 14 SPACE ONLY RECEPTACLE @ COL. 15 0.72 2011 16 SPACE ONLY RECEPTACLE - EXTERIOR 17 0.72 2011 18 SPACE ONLY SPACE ONLY 19 20 SPACE ONLY SPACE ONLY 21 22 SPACE ONLY SPACE ONLY 23 24 SPACE ONLY SPACE ONLY 25 26 SPACE ONLY SPACE ONLY 27 28 SPACE ONLY SPACE ONLY 29 30 SPACE ONLY SPACE ONLY 31 32 SPACE ONLY SPACE ONLY 33 34 SPACE ONLY SPACE ONLY 35 36 SPACE ONLY SPACE ONLY 37 38 SPACE ONLY SPACE ONLY 39 40 SPACE ONLY SPACE ONLY 41 42 SPACE ONLY SUB TOTALS. 1.64 1 1.64 1 1.64 1 2.0 3.64 1 2.0 1 364 2.0 3.64 1 10.92 KVACONNECTED PANELBOARD SCHEDULES NOT TO SCALE MOUNTING SYMBOL DESCRIPTION: HEIGHT LIGHTING AHJ AUTHORITY HAVING JURISDICTION Q 2'x4' FLUORESCENT FIXTURE. CEILING w--0 FLUORESCENT STRIP LIGHTING FIXTURE. CEILING O CEILING LIGHTING FIXTURE. CEILING Q WALL MOUNTED LIGHT FIXTURE. AS SPECIFIED O PENDANT MOUNTED LIGHT FIXTURE. CEILING ® EXIT LIGHT, SINGLE FACE. CEILING AmiP BATTERY OPERATED EMERGENCY LIGHT FIXTURE. 8'-0" AFF $ SINGLE POLE SWITCH. 48" AFF POWER SWITCH FVNR Ow DUPLEX RECEPTACLE. 18" AFF & DUPLEX GROUND FAULT CIRCUIT INTERRUPTED RECEPTACLE. 18" AFF ® SPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AS SHOWN 18" AFF 0 JUNCTION BOX WITH BLANK PLATE; BRACKET INDICATES WALL MOUNTED. HP HORSEPOWER PANELBOARD. 6"-6' TO TOP ® DISTRIBUTION PANELBOARD. 6"-6' TO TOP VOLTS METER SOCKET, PROVIDE PER UTILITY COMPANY REQUIREMENTS IN -USE COVER El SHUNT TRIP PUSH BUTTON 54" AFF E TRANSFORMER (NUMBER INDICATES KVA, EX: 45=45KVA). AS NOTED FIRE ALARM - NOT USED COMMUNICATIONS - NOT USED EQUIPMENT SYMBOLS 0 MOTOR AND CONNECTION EQUIPMENT TYPE AS NOTED. REFER TO CONNECTION SCHED. COORDINATE WITH INSTALLED EQUIPMENT p+ SAFETY DISCONNECT SWITCH -30A, 30, 48OV, NF, HD, NEMA 1, U.N.O. ev COMBINATION MOTOR STARTER & NON-FUSED DISCONNECT SWITCH, UNLESS NOTED OTHERWISE. "P' = FUSED; WE" = NON-FUSED. �- SPECIAL CABINET OR EQUIPMENT AS NOTED, RECESED MOUNTED. $u MANUAL MOTOR STARTER WITH OVERLOAD HEATERS FOR 120V, 10 FRACTIONAL HP. MOTORS. EP ENCLOSED CIRCUIT BREAKER IN NEMA I ENCLOSURE, U.N.O. CONDUIT, RACEWAYAND WIRING EACH CIRCUIT SHALL CONSIST OF PHASE, NEUTRAL AND GROUND CONDUCTORS. CONTRACTOR MAY COMBINE CIRCUITS INTO A COMMON HOMERUN CONSISTING OF A MAXIMUM OF A COMMON NEUTRAL/GROUND AND (2) PHASE CONDUCTORS (A, B). "'-"`` HOME RUN TO PANEL, NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS ALL HOMERUNS SHALL BE 1# 10 AWG, 314"C., MINIMUM. GROUNDING CONDUCTOR. -----~-CONDUIT IN/UNDER SLAB. CONDUIT CAP. -0 DN CONDUIT STUB -DOWN. -o UP CONDUIT STUB -UP. A DETAIL NUMBER. E t ELECTRICAL SHEET NUMBER. SECURITY - NOT USED DEMO. AND RENO. ABBREVIATIONS <F> EXISTING TO REMAIN. < N > NEW WORK -NOT USED WHERE WORK IS OBVIOUSLY NEW. SCREENED LINES INDICATE EXISTING EQUIPMENT TO REMAIN. DARK LINES INDICATE NEW WORK. GENERAL NOTES (APPLIES TO ALL DIVISION 16000 DRAWINGS) 1. WHERE THE REQUIREMENTS OF ANOTHER DIVISION EXCEED THE REQUIREMENTS OF THIS DIVISION, THOSE REQUIREMENTS SHALL GOVERN ENGINEER SHALL HAVE FINAL DECISION OF WHICH REQUIREMENT SHALL GOVERN, 2. ALL CONDUIT IN SLABIBELOW SLAB SHALL BE 314" MINIMUM. 3. ALL SYMBOLS PRESENTED MAY NOT NECESSARILY BE USED ON THESE DRAWINGS. ABBREVIATIONS A AMPS/AMPERAGE MCB MAIN CIRCUIT BREAKER AHJ AUTHORITY HAVING JURISDICTION MLO MAIN LUGS ONLY C.1CDT. CONDUIT MMS MANUAL MOTOR STARTER C. B, CIRCUIT BREAKER NEC NATIONAL ELECTRICAL CODE CLG CEILING NF NON-FUSED DISC DISCONNECT RGS RIGID GALVANIZED STEEL DN DOWN ST SHUNT TRIP EC ELECTRICAL CONTRACTOR SW SWITCH FVNR FULL VOLTAGE NON REVERSING STARTER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR GEL GROUND FAULT INTERRUPTOR UNO UNLESS NOTED OTHERWISE GND.1G. GROUND W WATTS HP HORSEPOWER WP WEATHERPROOF (NEMA 3R) IMC INTERMEDIATE METAL CONDUIT V VOLTS LUC IN -USE COVER XFMR TRANSFORMER KW KILOWATTS 0 PHASE KVA KILO VOLTAMPERES 0' DRAWING NOTE MNT MOUNTING SYMBOL LEGEND AND GENERAL NOTES NOT TO SCALE di\1i,t)ioN 6 - ELECTZICAL -x)pECFiCATi0N,5 16000 GENERAL ELECTRICAL REQUIREMENTS A. THE COMPLETE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF THE FOLLOWING CODES & STANDARDS 1. NFPA 70 NATIONAL ELECTRICAL CODE 2002 ED. 2. NFPA 780 LIGHTNING PROTECTION CODE. 3. NFPA 101 LIFE SAFETY CODE, 4. NFPA 110 STANDARD FOR EMERGENCYAND STANDBYPOWER SYSTEMS. 5. ANSI A117.1 ACCESSIBILITY CODE, 6. FLORIDA AMERICANS WITH DISABILITIES ACCESSIBILITY IMPLEMENTATION ACT AS DESCRIBED IN ACCESSIBILITY REQUIREMENTS MANUAL, DEPARTMENT OF COMMUNITY AFFAIRS 7. AMERICANS WITH DISABILITIES ACT. 8, FLORIDA BUILDING CODE 2004. R FLORIDA FIRE PREVENTION CODE 2004 Ed. B. "FURNISH AND INSTALL' AND "PROVIDE" ARE EQUIVALENT TERMS WHICH INDICATE MATERIAL AND/OR EQUIPMENT SUPPLIED AND INSTALLED BY THIS CONTRACTOR. C. IT IS THE REQUIREMENT OF THESE CONTRACT DOCUMENTS TO HAVE THE CONTRACTOR PROVIDE SYSTEMS AND COMPONENTS THAT ARE FULLY COMPLETE AND OPERATIONAL AND FULLY SUITABLE FOR THE INTENDED USE. D. DRAWINGS ARE DIAGRAMMATIC AND SHOULD NOT BE SCALED TO DETERMINE EXACT LOCATIONS. VERIFYALL LOCATIONS AND REQUIREMENTS OF EQUIPMENT FURNISHED AND/OR INSTALLED BY OTHERS BEFORE ROUGHING IN. E. ELECTRICAL SYSTEMS SHALL BE INSTALLED AS A COMPLETE INSTALLATION. INCIDENTAL DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER INSTALLATION AND OPERATION SHALL BE INCLUDED IN THE WORK OF THIS CONTRACTOR. F. PREBID SURVEY. 1. THIS CONTRACTOR SHALL SURVEY THE JOBSITE PRIOR TO SUBMITTING THEIR BID TO DETERMINE THE FOLLOWING: a. AREAS REQUIRING DEMOLITION, TEMPORARY POWER, RELOCATING, ETC_ WHICH ARE INADVERTENTLY NOT SHOWN ON THE DRAWINGS. b. PROBLEMS WITH WORK SEQUENCE. 2. ANY UNUSAL CONDITIONS NOT SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE ENGINEER PRIOR TO BIDDING. G. ACCEPTABLE MANUFACTURERS: THE LISTING OF A MANUFACTURER AS'ACCEPTABLE" UNDER ANY DIVISION 16 REQUIREMENTS DOES NOT IMPLY AUTOMATIC APPROVAL ITIS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ANY SUBMITTALS MADE ARE FOR PRODUCTS THAT MEET OR EXCEED THE SPECIFICATIONS INCLUDED HERE. H UPON COMPLETION OF THE WORK, BUT BEFORE FINAL ACCEPTANCE OF THE SYSTEM AND REQUEST FOR FINAL PAYMENT, FURNISH THE OWNER, FOR APPROVAL, OPERATION AND MAINTENANCE MANUALS IN LOOSE-LEAF BINDERS. PROVIDE A MINIMUM OF 6 SETS 1, PROVIDE OWNER WITH A RECORD SET OF AS -BUILT DRAWINGS FROM A DESIGNATED MARKED -UP SET OF BLUELINES J. PROVIDE TEMPORARY ELECTRICAL POWER TO JOBSITE FOR THE DURATION OF THE PROJECT. K. SUBMIT SHOP DRAWINGS FOR ALL ELECTRICAL ITEMS. THE SHOP DRAWINGS SHALL BE SUBMITTED COMPLETE FOR ALL ELECTRICAL ITEMS INCOMPLETE SUBMITTALS WILL BE RETURNED WITHOUT BEING REVIEWED. L PROVIDE 4" HIGH CONCRETE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT (SWITCHBOARDS, TRANSFORMERS, ETC.)). M. ALL EQUIPMENT, DEVICES, ETC. FURNISHED BYELPRICAL CONTRACTOR SHALL BE UL LISTED (OR EQUIVALENT NATIONAL TESTING AGENCY) FOR ITS INTENDED PURPOSE. INFORM OWNER THAT ALL OWNER FURNISHED EQUIPMENT, DEVICES, ETC. MUST ALSO HAVE UL LISTING (OR EQUIVALENT LISTING). N. ALL ELECTRICAL COMPONENTS (CONDUIT, WIRE, FITTINGS, SUPPORTS, CIRCUIT BREAKERS, ETC.) PROVIDED AND INSTALLED IN THIS PROJECT SHALL BE BRAND NEW. 0. UTILITY COORDINATION. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF CONSTRUCTION DOCUMENTS TO UTILITY COMPANY IMMEDIATELY AFTER RECEIVING NOTICE TO PROCEED OR PRIOR TO ANY SITE OR BUILDING ROUGH -IN. COORDINATE EASEMENT LOCATIONS BETWEEN OWNER AND UTILITY COMPANY. VERIFY WITH UTILITY COMPANY.- PROPOSED VOLTAGE, PHASE, POLE/PAD-MOUNT TRANSFORMER LOCATIONS, METERING, UTILITY PRIMARY ROUTING AND CONDUIT REQUIREMENTS, ETC, 16020 ELECTRICAL IDENTIFICATION A. PROVIDE CABLE/CONDUCTOR IDENTIFICATION BANDS. B PROVIDE ENGRAVED PLASTIC LAMINATE SIGNS, WHITE LETTERING ON A BLACK BACKGROUND, FOR EACH UNIT OF THE FOLLOWING CATEGORIES OF ELECTRICAL WORK: SWITCHBOARDS, MOTOR STARTERS, TRANSFORMERS, PANELBOARDS, DISCONNECTS, AND JUNCTION BOXES. NAME PLATES SHALT IDENTIFY PANEL DESIGNATION (NAME), VOLTAGE, PHASE AND WIRE CONFIGURATION. C. UNDERGROUND CABLE/CONDUIT IDENTIFICATION PLASTIC UNE MARKERS SHALL BE PROVIDED THE CONTINUOUS TRENCH LENGTH. 16040 ELECTRICAL DEMOLITION AND ALTERATIONS A. ANY EXISTING CIRCUITS OR EQUIPMENT NOT SHOWN ON DRAWINGS AND WHICH ARE LOGICALLY EXPECTED TO BE CONTINUED IN SERVICE SHALL BE RECONNECTED IN AN APPROVED MANNER. B. WIRING TO ELECTRICAL EQUIPMENT BEING DISCONNECTED SHALL BE REMOVED BACK TO THEIR OVERCURRENT DEVICE OR BACK TO NEAREST ACTIVE JUNCTION BOX. C. CONTRACTOR SHALL PROVIDE SUPPORT FOR EXISTING CONDUIT IN REMODELED AREA THAT IS TO REMAIN AND IS NOT PROPERLY SUPPORTED IN ACCORDANCE WITH N.E.C. REQUIREMENTS D. EXCEPT FOR CONDUIT, CONDUCTORS AND MISCELLANEOUS HARDWARE, ALL ELECTRICAL EQUIPMENT SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE STORED OR DISPOSED OF AS DIRECTED BY OWNER. 16111 CONDUIT A. MINIMUM SIZE CONDUIT SHALL BE 3/4". B. CONDUIT SHALL BE ELECTRICAL METALLIC TUBING, OR RIGID GALVANIZED STEEL CONDUIT. SCHEDULE 40 PVC CONDUIT IS ALLOWED FOR CONDUITS IN/UNDER THE SLAB AND UNDERGROUND. C. CONDUIT SHALL BE EMT IN INTERIOR AREAS, AND RIGID GALVANIZED STEEL CONDUIT IN EXTERIOR AREAS. D. COORDINATE ROUTING (LOCATION) OF CONDUIT WITH HVAC DUCTWORK, PLUMBING PIPING AND SPRINKLER PIPING, E. SECURE CONDUIT IN PLACE WITH CORROSION -PROOF ALLOY STRAPS AT SPACINGS AS REQUIRED BY N.E.C. CONDUIT SHALL BE SECURED TO BUILDING STRUCTURE. F. INSTALL FLEXIBLE STEEL CONDUIT NOT OVER X LONG TO MOTORS, TRANSFORMERS AND EQUIPMENT SUBJECT TO VIBRATION. G. INSTALL LIQUID -TIGHT FLEXIBLE CONDUIT NOT OVER 3' LONG WHERE SUBJECT TO MOISTURE, DIRT OR FUMES H. CONTRACTOR SHALL MINIMIZE FLOOR SLAB PENETRATIONS I. ALL CONDUIT RUNS SHALL BE DESIGNED TO PRESENT A NEAT AND ORDERLYAPPEARANCE, RUNNING LINES PARALLEL WITH BUILDING STRUCTURE OR WALLS. J. ROOFTOP UNITS AND EXHAUST FANS ARE TO BE WIRED THROUGH THE ROOF CURBS OR UTILIZE FACTORY -FABRICATED ROOF PIPING CURBS PITCH POCKETS ARE NOT ALLOWED. K. CONDUIT SHALL BE ROUTED PERPENDICULAR THROUGH RATED WALLS. PROVIDE PROPER SLEEVES AND FIRE SAFING/SEALANTS. L. PROVIDE UL APPROVED FIRE SEALS FOR ALL FIRE RATED WALL AND FLOOR PENETRATIONS 16115 CONDUIT FITTINGS A. COMPRESSION TYPE STEEL OR STEEL SETSCREW TYPE SHALL BE UTILIZED. B. PROVIDE PROPER EXPANSION FITTINGS WHEN CROSSING BUILDING EXPANSION LINES. 1.6120 WIRES, CABLES AND CONNECTORS A. ALL CONDUCTORS SHALL BE COPPER WITH 600V 90"C THHN/THWN INSULATION, B. USE SOLID CONDUCTOR, SINGLE CONDUCTOR, NO. 12 AWG MINIMUM FOR GENERAL USE WIRING. C. USE STRANDED CONDUCTOR, SINGLE CONDUCTOR NO. 12 AWG AND LARGER, FOR MOTORS AND OTHER INSTALLATIONS WHERE VIBRATION IS GENERATED. D. COLOR -CODING SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM, FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITRY. ALL WIRING SHALL BE COLOR -CODED AS FOLLOWS 2081120 VOLT 480/277 VOLT PHASE A -BLACK PHASE A -BROWN PHASE B -RED PHASE B -ORANGE PHASE C -BLUE PHASE C- IN NEUTRAL -WHITE NEUTRAL -WHITE WITH TRACER OR GRAY E A STANDARD 500V MEGGER INSULATION TEST SHALL BE MADE AND RECORDED FOR ALL FEEDER CIRCUITS PROVIDE A COPY OF TEST RESULTS TO ENGINEER FOR REVIEW. F. PROVIDE LUGS FOR FEEDER SIZES INDICATED ON DRAWINGS OR AS REQUIRED. G. WIRE SIZE FOR 120V BRANCH CIRCUITS SHALL BE PER THE FOLLOWING LENGTH OF RUNS: 1. 0 TO 50 FT- RUN FROM PANELBOARD TO FIRST OUTLET, N0, 12 AWG MINIMUM. 2. 51 TO 100 FT RUN: INCREASE ONE WIRE SIZE, I.E. NO. 12 AWG BECOMES NO. 10 AWG TO FIRST OUTLET. 3. 101 TO 150 FT RUN. INCREASE TWO WIRE SIZES, L E. N0. 12 AWG BECOMES NO. 8 AWG TO FIRST OUTLET, 4. 151 AND ABOVE: WIRING SHALL BE SIZED FOR 3% MAXIMUM VOLTAGE DROP. 16130 BOXES DRAWING NAME A. WALL OUTLET BOXES SHALL BE 4 INCH SQUARE WITH A TOTAL DEPTH OF LESS THAN SYMBOL LEGEND, GENERAL NOTES, 2-1/2" GALVANIZED PRESSED STEEL WITH PLASTER RINGS OR GANG COVER, OR SIZED ELECTRICAL SPECIFICATIONS, AND AS REQUIRED. PANELBOARD SCHEDULES B. WHERE MORE THAN TWO DEVICES ARE LOCATED AT ONE POINT, USE GANGED BOXES FLOOR PLAN - POWER AND COVERS, POWER ONE -UNE DIAGRAM, AND C. ALL BOXES FOR ELECTRICAL EQUIPMENT SHALL HAVE COVERS, D. DO NOT INSTALL BOXES BACK TO BACK OR THROUGH WALL OFFSET OUTLET BOXES ON OPPOSITE SIDES OF WALL A MINIMUM OF 12 INCHES OR ON OPPOSITE SIDES OF STUD IN PARTITION WALLS. 16140 WIRING DEVICES A. WIRING DEVICES SHALL BE MANUFACTURED BY HUBBELL, BRYANT OR LEWTON. B. RECEPTACLES SHALL BE HEAVY DUTY DUPLEX, 2 POLE, 3 WIRE, GROUNDING, 20 AMP, 125 VOLT, DESIGNED FOR SIDE AND BACK WIRING WITH NEMA CONFIGURATION 5-20R, DESIGN SELECTION HUBBELL CR -5352-1. C. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES SHALL BE NEMA 5-20R AND EQUAL / TO HUBBELL GFR -5352-L D. SWITCHES SHALL BE HEAVY DUTY SINGLE POLE AC QUIET SWITCHES, 20 AMPERES, EQUAL I n TO HUBBELL CS -1221-1, CS -1223-I (THREE-WAY), CS -1224-1 (FOUR-WAY). E. PROVIDE SMOOTH NYLON COVERS FOR ALL DEVICES 16155 MOTOR STARTERS A. PROVIDE STARTER OF NEMA SIZE AND VOLTAGE RATING COMPATIBLE WITH MOTOR. B. MANUFACTURERS SHALL BEG. E., SQUARE 'Lr OR SIEMENS, C. AC FRACTIONAL HORSEPOWER MANUAL STARTERS, 2 POLE, SIZE AND RATING AS RE N EQUIP WITH MANUALLY OPERATED TOGGLE -MECHANISMS AND WITH ONE PIECE MEL x" ALLOY TYPE THERMAL UNITS, GREEN PILOT LIGHT, AND SWITCH CAPABLE OF BEING PA LOCKED OFF. ENCLOSE STARTER IN NEMA TYPE I ENCLOSURE. SQUARE 'D" TYPE 'P. D. MEGGER CHECK PHASE -TO -PHASE AND PHASE -TO -GROUND INSULATION LEVELS DO NOT MEGGER CHECK SOLID-STATE EQUIPMENT. TEST EACH MOTOR AND RECORD NAMEPLATE DATA, OVERLOAD RELAY EQUIPMENT PROTECTIVE RELAY SETTING, VOLTAGE AND CURRENT PHASE READINGS AND DIRECTION OF ROTATION. E. MAGNETIC COMBINATION NON -REVERSING STARTERS WITH CIRCUIT BREAKERS, EQUIP STARTERS WITH BLACK TYPE MANUAL RESET OVERLOAD RELAYS PROVIDE ONE NORMALLY OPEN AND TWO NORMALLY CLOSED AUXILIARY CONTACTS. PROVIDE MINIMUM 50VA CONTROL VOLTAGE TRANSFORMER WITH VOLTAGE AS REQUIRED BUT NOT TO EXCEED 120V. PROVIDE ok ENCLOSURE IN SIZE AND NEMA RATING AS REQUIRED. EQUIP WITH PHASE FAILURE UNDERVOLTAGE, AND PHASE UNBALANCE RELAY PROTECTION PROVIDE OPERATING HANDLE O FOR DISCONNECT SWITCH MECHANISM WITH INDICATION AND CONTROL OF SWITCH POSITION, WITH ENCLOSURE DOOR EITHER P R OPENED 0 CLOSED, AND CAPABLE OF BEING LOCKED IN OFF POSITION, WITH A PADLOCK. SQUARE 'D' CLASS 8539. O 16160 PANELBOARDS A. PANELBOARDS SHALL BE MANUFACTURED BY SQUARED', GENERAL ELECTRIC, OR ITE SIEMENS B. PROVIDE LIGHTING AND APPLIANCE PANELBOARDS, AND POWER DISTRIBUTION PANELBOARDS WITH DEAD FRONT COVERS, FULL SIZE NEUTRAL AND BOLT -ON HEAVY DUTY, QUICKMAKE, QUICK BREAK CIRCUIT BREAKERS. PANELBOARDS SHALL BEUL. LISTED. w C. INSTALL PANELBOARDS SO TOP BREAKER IS NOT HIGHER THAN 6'-0" ABOVE FLOOR. r r� D. CONTRACTOR SHALL BALANCE PHASES IN PANELBOARD SO THAT LOAD IMBALANCE DOES NOT p{,w EXCEED 16%. ®1 E. PANELBOARD SMALL INCLUDE COMPLETE TYPEWRITTEN DIRECTORY. �� F. PROVIDE 120V POWER TO 480V CIRCUIT BREAKER SHUNT -TRIPS FROM NEAREST 120V 4 PANELBOARD. ` �,+'j Of Is G. PROVIDEU1 LISTED BREAKERS FOR EXISTING PANELBOARDS TO MATCH MANUFACTURER G AND AIC RATING. H. ALL BREAKERS SERVING MECHANICAL, REFRIGERATION, OR OTHER EQUIPMENT WHERE REQUIRED, SHALL BE HA CR RATED. I. BREAKERS WITH HID LIGHTING LOADS SHALL BE HID RATED. 16161 METER CENTERS - NOT USED 16163 SWITCHBOARDS A. SWITCHBOARDS SHALL BE SQUARED' QED -S POWER -STYLE GROUP MOUNTED MULTI - SECTION SWITCHBOARDS B, SWITCHBOARDS SHALL BE DEAD -FRONT AND TOTALLY FRONT ACCESSIBLE. C. PROVIDE STAND ALONE, MICROPROCESSOR BASED, THREE-PHASE POWER METERING DEVICE MOUNTED RECESSED IN FRONT OF SWITCHBOARD. SQUARED' POWER LOGIC MODEL CM2250, PROVIDE CURRENT -TRANSFORMERS AND RELAYING IN SIZES AS REQUIRED. D. MAIN BREAKER SHALL BE 100% CURRENT RATED AND INCLUDE GROUND FAULT AND SHUNT -TRIP E. MEGGER CHECK PHASE -TO -PHASE, PHASE -TO -NEUTRAL, AND PHASE -TO -GROUND INSULATION LEVELS PRIOR TO ENERGIZATION. 16170 MOTOR AND CIRCUIT DISCONNECTS A. DISCONNECT SWITCHES SHALL BE HEAVY DUTY. B. PROVIDE RAIN -TIGHT HUBS FOR EXTERIOR DISCONNECTS, C. PROVIDE CLASS R REJECTION FUSE CLIPS AND CLASS R FUSES, D. FUSES SHALL BE MANUFACTURED BY BUSSMAN, LITTLE OR GOUL D-SHOUWMUT. 16190 SUPPORTING DEVICES A. FIXTURES SHALL BE SUPPORTED FROM BUILDING STRUCTURE. B. FASTEN CONDUIT TO STRUCTURAL PARTS OF BUILDING. 16450 GROUNDING A. PROVIDE INSULATED GROUh,D CONDUCTORS IN ALL CONDUITS. B. PROVIDE GROUNDING BUSHINGS FOR FEEDER CONDUITS C. TRANSFORMERS SHALL BE GROUNDED TO BUILDING STEEL WITH EXOTHERMIC CONNECTIONS. D. SERVICE GROUND RESISTANCE SHALL BE MEASURED WITHOUT DEPENDING ON WATER PIPING SYSTEM AND SHALL BE 25 OHMS OR LESS, IF GREATER THAN 25 OHMS, DRIVE ADDITIONAL GROUND RODS TO OBTAIN REQUIRED RESISTANCE. 16461 TRANSFORMERS A. TRANSFORMERS SHALL BE DRY TYPE WITH VENTILATED ENCLOSURES AND 115°C TEMPERATURE RISE ABOVE 40°C. B. PROVIDE PRIMARY WINDINGS WITH 6 TAPS, (2) 2 112% INCREMENTS ABOVE AND (4) 2 12% INCREMENTS BELOW FULL RATED / E VOLTAGE C. TRANSFORMERS SHALL BE RATED FOR CONTINUOUS OPERATION AT RATED WA. D. TRANSFORMERS SHALL HAVE CLASS H INSULATION. E. WALL MOUNTED TRANSFORMERS SHALL UTILIZE WALL MOUNTING BRACKETS WITH VIBRATION ISOLATION PADS. F. STRUCTURAL CEILING SUPPORTED TRANSFORMERS SHALL UTILIZE THREADED ROD AND UNISTRUT FRAME WITH VIBRATION ISOLATION PADS. SUPPORT STRUCTURE SHALL HAVE MINIMUM 3.0 SAFETY FACTOR. 4&CAA f rnuruIn A U. L LABELS MUST APPEAR ON ALL LIGHTING FIXTURES, B. LIGHTING FIXTURES IN MECHANICAL AREAS, ETC., SHALL BE COORDINATED WITH EQUIPMENT PLACEMENT. C. LAMPS SHALL BE MANUFACTURED BY OSRAM-SYLVANIA, G. E, PHILLIPS OR VENTURE. D. BALLASTS SHALL BE MANUFACTURED BY OSRAM-SYLVANIA, MAGNETIC -UNIVERSAL, ADVANCE, ESI OR VENTURE, E EMERGENCY BATTERY BALLASTS SHALL BE 1400 LUMENS MINIMUM. 16709 SURGE SUPPRESSION EQUIPMENT A. SURGE SUPPRESSORS AT SERVICE SHALL ALSO BE LISTED AS LIGHTNING ARRESTORS B. TVSS AT ENTRANCE SHALL BE LEA INTERNATIONAL GB -300S. TVSS'S AT PANELBOARDS SHALL BE LEA INTERNATIONAL LSS 150. ACCEPTED SUBSTITUTIONS BY LIEBERT OR LEVITON, C. PROVIDE LIGHTNING ARRESTOR ON SERVICE ENTRANCE 1F TVSS 1S NOT DUAL LISTED AS A LIGHTNING ARRESTOR. 16721 FIRE ALARM DETECTION SYSTEM - NOT USED 16741 COMMUNICATIONS CONDUIT RACEWAY SYSTEM - NOT USED ELECTRICAL SPECIFICATIONS ELECTRICAL SHEET INDEX FLORIDA EXTRUDERS INTERNATIONAL, INC. - 26824 DRAWING NUMBER DRAWING NAME E-1 SYMBOL LEGEND, GENERAL NOTES, CAD FILE NO: ELECTRICAL SPECIFICATIONS, AND SCALE: PANELBOARD SCHEDULES E-2 FLOOR PLAN - POWER E-3 POWER ONE -UNE DIAGRAM, AND ELECTRICAL CONNECTION SCHEDULE ,412,Cd ITLCTU Q AL coN�u�TiN� INO A.C.E.,� ELECTRICAL ENGI 517 SPRING VALLEY ROA ALTAMONTE SPRINGS, FL 32714 PHONE: (407) 339 - 3060 FAX: (407) 339 - 8121 E-MAIL,- gsigle@ace-mep.com GREG SIGLE, P.E. P.E. LICENSE NO: 48671 EBN # 8019/# 9682 ®C0PYRI7IIT ARCHITECTURAL CONSUL-11NOENG NEERIN0, INC_ All RIGHTS RFSFRVED. ELECTRICAL CONTRACTOR: TRIBE ) ENTERPRISES, INC. ,AREG CRAWFORD 1146 GREENSTONE BLVD # 102 HEATHROW, FL 32 746 PHONE/FAX: 407-833-4198 CELL: 407-314-7700 EMAIL: GREG-TRIBE@cfl.rr.com EC # 0000983 CBC # 057252 PROJECT: --�-REVISIONS: I NO. I DATE I DESCRIPTION JOB NUMBER: 26824 DATE: MAR. 9, 2006 CAD FILE NO: 26824-E001 SCALE: AS NOTED DRAWN: H. ADKINS CHECKED: G. SIGLE SHEET TITLE: SYMBOLS, NOTES, ELECTRICAL SPECIFICATIONS, AND PANELBOARD SCHEDULES SHEET NO: E-1 ---�► MSB -14 J B -2 TL—lb- MSB-13 64 I m WATER, OSMOSIS a;v' SYSTEM OTAL rv„ 0 FLOOR PLAN - POWER SCALE: 1/8" = 1'-0" POWER PLAN NOTES: OREFER TO ELECTRICAL DRAWING 'E-2', POWER ONE -LINE DIAGRAM, AND ELECTRICAL CONNECTION SCHEDULE FOR ADDITIONAL NOTES AND CIRCUIT REQUIREMENTS. TYPICAL O3#10, 1#10G., 3/4"C. (DI WATER) 4#10, 1#10G., 3/4"C. (REVERSE OSMOSIS) 4#4, 1#8G., 1 1/7C. (GLASS WATER SYSTEM) 0 3#6, 1#8G., 31,VC. (MACHINE CONTROL CABINET) 0 APPROXIMATE LOCATION OF EXISTING OVERHEAD SERVICE LOCATION. FIELD VERIFY. 0 APPROXIMATE LOCATION FOR NEW ELECTRIC SERVICE PADMOUNT TRANSFORMER BY ELECTRIC UTILITY WITH EASEMENT FOR PRIMARY RACEWAY TO FPC PRIMARY POLE. MAINTAIN ALL REQUIRED CLEARANCES - TYPICAL APPROXIMATE LOCATION FOR NEW KWH METER, BASE, AND CURRENT TRANSFORMER CABINET- INSTALLATION AS REQUIRED BY UTILITY. go APPROXIMATE LOCATION FOR NEW SHUNT TRIP SWITCH AND SIGNAGE AS REQUIRED BYAHJ. 1 APPROXIMATE LOCATION FOR SERVICE GROUND ROD TRIPLEX SYSTEM - (3) 314" X 104" DRIVEN RODS MINIMUM WITH RESISTANCE c 25 OHMS. 1 CONCRETE HOUSEKEEPING PAD - EXTEND 6" BEYOND EDGE OF EQUIPMENT - TYPICAL o COMPRESSOR 19 4 4R Cfl ITFCTU 12.,41_. CON't)U L.TI N(' IN v 4 A. C.E. ELECTRICAL ENGI 517 SPRING VALLEY kROA ALTAMONTE SPRINGS, FL 32714 PHONE: (407) 339 - 3060 FAX. (407) 339 - 8121 E-MAIL: gsigle@ace-mep.com GREG SIGLE, P.E. P.E. LICENSE NO: 48671 EBN # 8019/# 9682 ®COPYRIGHT ARCHITECTURAi. CONSULTI ORN(FCYRING, INC. ALL RIGHTS RESP.RVED. ELECTRICAL CONTRACTOR: TRIBE ENTERPRISES, INC. GREG CRAWFORD 1146 GREENSTONE BLVD #102 HEATHROW, FL 32746 PHONE/FAX: 407-833-4198 CELL: 407-314-7700 EMAIL: GREG-TRIBE@cfl.rr.com EC # 0000983 CBC # 057252 PROJECT: REVISIONS: NO. DATE DESCRIPTION A JOB NUMBER: 26824 DATE: MAR. 9, 2006 CAD FILE NO: 26824-EF1I SCALE: AS NOTED DRAWN: H. ADKINS CHECKED: G. SIGLE SHEET TITLE: FLOOR PLAN - POWER SHEET NO: E-2