HomeMy WebLinkAbout3941 W 1 Rd (3)RECEIVED) CITY OF SANF'ORD PERMIT AIIPLICA'1'ION Permit # : (DICJ \� r � �_ —ems Date: Job Address: 3941 West .3tm��4-6 — Sanford, Florida 32771 Description of Work; Provide added Horn/Storbes & riser tamper monitoring per-TVii Robles/FM. Historic District: Zoning: Value of Work: s_$ 2' 633. 00 Permit 'Type: Building Electrical Mechanical Plumbing Fir,' #WAlarm X Pool Electrical; New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plunlbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial X Industrial Total Square Footage: Construction Type: # of Stories: 1 # of Dwelling Units: Flood Zone; (FEMA form required for other than X) Parcel#: 28-19-30-506-0000-0120 (Attach Proof of Ownership& Legal Description) X Owners Name&Address: Dustin Rose/Recovery Room of Central Florida, Inc. 4765 Semoran Blvd. — Orlando, Florida 32822 Phone: 800-873-2580 Contractor Name&Address: Nutech Fire & Security, Inc. — 150 Candace Dr. — Maitland Florida 32751 State License Number: EF0000191 Phone &Fax:407-628-1600/407-539-1115 Contact Person: David D. Ramos Phone: X1602 Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer: Phone: Address: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of apermit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: l certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR, PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoeyttid n the public records of this county, and there may be additional permits required from other governmental entities such as water management districtstat�agencies, or federal agencies Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien -rrw, FS 713. . X. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID APPLICATION APPROVED BY Special Conditions: Bldg: Zoning: (Initial & Date) Signature of C—on2eTard'o, a`t' Date I®T,z, Grey o Print ontractor/Agent'sN*' re G—reg Derardo, President N4Tech Fire& Security, Inc. Milt �/ r 3/3 - FLORIDA Stgnaturc of [ tft ry-State of Florida ,µ P teBridget L Derr My Commisalon D0160264 „r/ Expires October 22, 2W6 Contractor/Agent is Z Personally Known to Me or Produced ID n Utilities: (Initial & Date) (Initial & Date) (Ii ,VIP UCV ED System No. C—AJ-1226 F RATING = 3—HR. T RATING = 0—HR. L Rating At Ambient — Less than 1 CFM/Sq Ft A—A L Rating At 400 F — 4 CFM/Sq Ft 1. FLOOR OR WALL ASSEMBLY — MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS. MAX DIA OF OPENING IS 32 IN, SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. METALLIC SLEEVE — (OPTIONAL) NOM 32 IN. DIA (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY, FLUSH WITH FLOOR OR WALL SURFACES. 3. THROUGH PENETRANT — ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1-7/8 IN. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED: A. STEEL PIPE — NOM 30 IN. DIA (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. COPPER PIPE — NOM 6 IN. DIA (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE, C. COPPER TUBING — NOM 6 IN. DIA (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. CONDUIT — NOM 6 IN. DIA (OR SMALLER) STEEL CONDUIT. E. CONDUIT — NOM 4 IN. DIA (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT). 4. FIRESTOP SYSTEM — THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL — MIN 4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL, B. FILL, VOID OR CAVITY MATERIAL — SEALANT — MIN 1/4 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL. AT THE POINT CONTACT LOCATION BETWEEN PIPE AND CONCRETE, A MIN 1/4 IN. DIA BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PIPE INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. HILTI, INC. — FS—ONE SEALANT BEARING THE UL CLASSIFICATION MARKING A PPE THRU SLEEVE IN CONCRETE FLOOR/WALL OR BLOCK WALL N.T.S. APPLICABLE ITEMIZED SCOPE FRONT VIEW T A SECTION A—A T UL/cUL SYSTEM NO. WL1054 F RATING = 1 -HR. OR 2 -HR. T RATING = 0 -HR. L RATING AT AMBIENT = LESS THAN 1 CFM/SQ. FT. L RATING AT 400'17 = 4 CFM/SQ. FT. F7 1. GYPSUM WALL ASSEMBLY (UL/ULC CLASSIFIED U300 OR U400 SERIES) (1—HR OR 2—HR FIRE—RATING) (2—HR SHOWN). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 30" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 30" NOMINAL DIAMETER CAST IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 3. HILTI FS—ONE INTUMESCENT FIRESTOP SEALANT: A. MINIMUM 5/8" DEPTH, FOR A 1—HR FIRE—RATING. B. MINIMUM 1-1/4" DEPTH, FOR A 2—HR FIRE—RATING, 4. MINIMUM 1/2" BEAD HILTI FS—ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT, NOTES : 1. MAXIMUM DIAMETER OF OPENING: A. 32-1/4" FOR STEEL STUD WALLS, B. 14-1/2" FOR WOOD STUD WALLS. 2. ANNULAR SPACE = MINIMUM 0", MAXIMUM 2-1/4". B METAL PIPE THROUGH 1—HR. OR 2—HR GYPSUM WALL ASSEMBLY NTS. SYSTEM OUTPUTS UNIT ANNUNCIATION NOTIFICATION 0 C_D �Q � _�' '`O v0 O� 4� O Q �C" SYSTEM INPUTS SYSTEM DESIGN, INSTALLATION, TESTING & ALL CODES REFERENCED ARE PER CHAPTER 69A-60 (FAC) OF THE FLORIDA FIRE PREVENTION D CODE 2004 EDITION, WITH ALL CODES AND STANDARDS REFERENCED THEREIN. I.E. NEPA 70 (NEC) 2002 & NFPA 72 (NFAC) 2002. H .REFER TO PUBLICATIONS FOR SPECIFIC DETAILS. J K ALL NOTIFICATION APPLIANCES TO BE MOUNTED (TO BOTTOM OF STROBE) @ NO LESS THAN 80" AFF, OR ABOVE STAGE, w 'PLATFORM OR MEZZANINE LEVELS. (ALSO SEE MOUNTING DETAIL) EOL TO BE INSTALLED AT LAST DEVICE ON CIRCUIT. • TAC EXPANDER PANEL TO BE MOUNTED (TO TOP) @ 60" AFF ADJACENT TO FACP. RISER TAMPER SWITCH BY OTHERS (CONNECTIONS ONLY) x BY OTHERS • SYSTEM OUTPUTS UNIT ANNUNCIATION NOTIFICATION 0 C_D �Q � _�' '`O v0 O� 4� O Q �C" SYSTEM INPUTS A B C D E F G H I J K L RISER TAMPER SWITCH MULTI -CANDELA HORN/STROBE PER RATING w • • 1 � RISER TAMPER SWITCH BY OTHERS (CONNECTIONS ONLY) • BY OTHERS • aX U W � �) Q � � o� L-L Z 0 J O CL :D 0 0V) UWW J SYSTEM INPUT/OUTPUT MATRIX EQUIPMENT LEGEND/DEVICE COUNTS QTY. SYM DESCRIPTION MOUNTING P/N MFR 0 170 EXISTING FIRE ALARM CONTROL PANEL WITH BATTERY BACKUP CABLE #OF PAIRS SYMBOL AWG SOLI D MFG WIRE# CIRCUIT DESCRIPTION 1 NAACC2 FIRE ALARM NAC EXPANDER PANEL WITH BATTERY BACKUP 600 AFF MIRBPS6 MIRTONE 4 OQttoco MULTI -CANDELA HORN/STROBE PER RATING w MIR-MGI-HDVM MIRTONE 1 � RISER TAMPER SWITCH BY OTHERS (CONNECTIONS ONLY) BY OTHERS BY OTHERS / I 2 RIGHT FRONT LEFT 0 4' 8' 16' 84' SCALE - 1/8" = 1' 3 I 4 ti o N,2-1-2 7 M10/2 )F 1= I CE EFSTI�G NEW n EXISTING c NAC1 N2-1-1 11 DCD {i7 +en WORK SPACE I 110CD N2-1-3 EOL NAC2-1 0 o N2-1-4 Pl 18/2 I 7 D TAMPER# PAINT PAINT MOUNTING DETAIL FOR VISUAL, AUDIBLE/VISUAL & MANUAL PULL STATION MOUNTING DETAIL N. T. S. W WIRE LEGEND I CABLE #OF PAIRS SYMBOL AWG SOLI D MFG WIRE# CIRCUIT DESCRIPTION 18/2 1 PAIR 18 AWG WEST PENN 980 INITIATING DEVICES 16/2 1 PAIR 16 AWG WEST PENN 990 HORN/STROBES o N,2-1-2 7 M10/2 )F 1= I CE EFSTI�G NEW n EXISTING c NAC1 N2-1-1 11 DCD {i7 +en WORK SPACE I 110CD N2-1-3 EOL NAC2-1 0 o N2-1-4 Pl 18/2 I 7 D TAMPER# PAINT PAINT MOUNTING DETAIL FOR VISUAL, AUDIBLE/VISUAL & MANUAL PULL STATION MOUNTING DETAIL N. T. S. THE SHARP CAR STORE/RECOVERY ROOM OF CENTRAL FLORIDA, INC. FIRE ALARM SYSTEM INSTALLATION ADDITION 5 6.3.5.1 Location of AUDIBLE devices: Where ceiling heights allow, wail—mounted appliances shall have their tops at heights above the finished floors not less than 90" and below the finished ceilings of not less than 6 inches. Mount in ceiling as shown on plans. 6.4.4 APPLIANCE Location Wall—mounted appliances shall have their bottoms at heights above the finished floor of not less than 80" and no greater than 96". (Where the ceiling height is less than 90", mount the AUDIBLE/VISUAL device such that the top is 6" below the ceiling) 5-8.1.1 Mounting for FIRE ALARM BOXES The operable part of each FIRE ALARM BOX shall be not less than 3-1/2 feet and not more than 4-1/2 feet above floor level W = Q W - o Z U Q Q Ct' a- U U U U > Q Q w z zII o N#-#-# 0 NAC DEVICE LABEL THE SHARP CAR STORE/RECOVERY ROOM OF CENTRAL FLORIDA, INC. FIRE ALARM SYSTEM INSTALLATION ADDITION 5 6.3.5.1 Location of AUDIBLE devices: Where ceiling heights allow, wail—mounted appliances shall have their tops at heights above the finished floors not less than 90" and below the finished ceilings of not less than 6 inches. Mount in ceiling as shown on plans. 6.4.4 APPLIANCE Location Wall—mounted appliances shall have their bottoms at heights above the finished floor of not less than 80" and no greater than 96". (Where the ceiling height is less than 90", mount the AUDIBLE/VISUAL device such that the top is 6" below the ceiling) 5-8.1.1 Mounting for FIRE ALARM BOXES The operable part of each FIRE ALARM BOX shall be not less than 3-1/2 feet and not more than 4-1/2 feet above floor level O U W = Q x oLi 0 � O U W a. a O 0 �0 P� Q aX U W � �) Q � � o� L-L Z 0 J O CL :D 0 0V) UWW J _m a U� o cn w Ln Q 0 "--1 z a 0 o Z 0 �z O o �M Q W � M O W 0 af r OfO W O U 0� WCn f - >o UUUI W J Q W = _ = Q U W 0 O Z Z 0 LD re a00 �x0 0-0-5 Q�W 3wLO� in =w azo = 3 F- L)O Z IW = oz3 Amo wow Q_ LJ � Xm 0-0 jW<M cn a W J Uw0 wj3 WwW = cn O NHQ Z 0 Z 3LA— ouz 00-3 = O H Z 0 Nj 0 x 0 � O 0 O "n_� �0 Q � 0 Q � � W O O co O a V L w Ln "--1 0 0� WCn f - >o UUUI W J Q W = _ = Q U W 0 O Z Z 0 LD re a00 �x0 0-0-5 Q�W 3wLO� in =w azo = 3 F- L)O Z IW = oz3 Amo wow Q_ LJ � Xm 0-0 jW<M cn a W J Uw0 wj3 WwW = cn O NHQ Z 0 Z 3LA— ouz 00-3 = O H Z 0 Nj 0 x 0 0 �0 0 1 W O O co O a V L w M O 0 Qi W V 1 r r~ h+l W m 0� WCn f - >o UUUI W J Q W = _ = Q U W 0 O Z Z 0 LD re a00 �x0 0-0-5 Q�W 3wLO� in =w azo = 3 F- L)O Z IW = oz3 Amo wow Q_ LJ � Xm 0-0 jW<M cn a W J Uw0 wj3 WwW = cn O NHQ Z 0 Z 3LA— ouz 00-3 = O H Z 0 Nj JOB NO: 06-042 SHEET 1 OF 1 FA -01 x 0 �0 0 1 I co M O 0 M r m m x w 1A i= C UC1 fl M > H N 0 Z Y 3 U o w W w J Ce L U QJ 1i O N N V�1 JOB NO: 06-042 SHEET 1 OF 1 FA -01