Loading...
HomeMy WebLinkAbout103 Lake Ada Cir (4)CITY OF SANFORD PERMIT APPLICATION Permit # Job Address: Description of Work: RIIyWE & n Date: N Historic District: Zoning: Value of Work: S AP / • t/ / Permit Type: Building XX Electrical Mechanical Plumbing Fire SprinkledAlarm Pool Electrical: New Service - # of AMPS Addition/Altetation Change of Service Temporary Pole _ Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: #.of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #://'&((J-JU—JV /' Owners Name & Address-_Kad% Attach Proof of Ownership TT/lT/ylLu /'C ,E Phone: iu 7".—,"o o[ Contractor Name & Address: REBBCA BERNAMAME' S COMP HIES, .8529 S. PARK CIRCLE, SUITE 430, ORLANDO, FL 32819 State License Number. CR C057468 2 4 7-327-0910 7ACKIE CAT 7F 407-467-2643Pbone6rFaxContactPersojC _ .n"?`S't[ Phone: Bonding Company: PIE' Address: Mortgage Lender: NA Address: Architect/Engineer: Nk Address: Application is hereby made to obtain a permit to do 1he4prk and issuance of a permit and that all work will be performed l%meet s CpermitmustbesecuredforELECTRICAL WORK, PLUP#BING, AIR CONDITIONERS, etc. .. , . Phone: Far:: that no work or installation has commenced prior to the tructicA idibis jurisdiction. I understand that a separate ACES, BOILERS, HEATERS, TANKS, and 1-1 OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. Signature of Owner/Agent Date Signature of Contractor/Agent Date rT) nd U fitvl rrYeS Print Owner/Agent's Name I iir(NCPgtractor/A' nt's Name n Signature of Notary -State of Florida Date Owner/Agent is _ Personally Known to Me or Produced ID ofFlolasr%tsteRLURII1W A. DE GRAVE Date MY COMMISSION II DD 164260 EXPIRES: November 12, 2006 Contractor/Agent is Personally WiioWillb7tfe or Produced ID APPLICATION APPROVED BY: BldV1E 7 b l Zoning: Utilities: FD: Initial & Date) (Initial & Date) (Initial & Date) (Initial & Date) Special Conditions: . 4 goo 407-430-4069 1657- INSTALLED SALES P 3/5 c r CONTRACT 13780 7 ONTRIt INSTALLS SALES SPECIAI.IST NUrnuER' CUSTUVIER STORE NO. STREET ADDRESS J t 1 TrtEET wDORFSS ZIP srnTt/ //7 r: ! PITY % STATE ZIP TELEPNONF iLLEPHUNE .....; NUMSC C.A6M RAH kCC d 1 nFj LCANE' t CONTRACTOFl LICENSE f1 h Y i.n u DAThis is a contract between Lowe s (as defined in the Terms and Conditions) ('Lowe's'). and the ataove-reamed Customer for the installation of goods at the Customers residential premises (the'Premises") at the f011_ovMg irrstallaUOn addrosv' STREET ADDRESS STn ZIP CITY Lowe' s to arrange normal installation of the following -aoor(a)- Exterior Interior Pre/hung Unit sly For warranty to be valid - Item Number .&.? /6-, RH 0 LH customer must finish frame and all six (6) sides of door Door( s) Size 36 x 80 32x80 Other Size immediately (within 5 days) Item NUmber-SO RH LH after installation. Doors) Size 6 x BO 32x80 L7 Other Size -- Customer initials D Delivery of Door Yes No (check one) Haul away of any debris related to installation: Yes r l No (check one) Basic Installation includes the following: Normal Installation of door in same size square opening in good condition Installation of hardware with pre -bored door Reinstallation of present casing or customer provided new casing Clean- up of job -site Basic Installation does not include the following: Reframing or alterations to existing structure or carpentry work resulting from old or damaged structure Any reinstallation of Burglar Alarms Any painting or staining or finishing of new door unit Reinstallation of Screen or Storm or Security Door Reinstallation of vinyl or aluminum covering on exterior molding With the exception of Burglar Alarms and finishing, any of the above labor items can be contracted at an additional Cost and must be specifically listed in the additional specifications block on this contract. 77 Additional Specif/caTlons: The Environmental Protection Agency (EPA) has requested that Lowahs notify fnste"stlorr customers iMat a fetmbseed-palm hararc maT a at t+tilwallilim +bul prior to1978- See pamphlet EPA 747-K-99-001 for details. - Lb %_ 4 , rMf NOTICE TO CUSTOMER / rC All Items listed in this Contract and specification sheet(s) are to be installed under conditions agreed upon at time of purchase and at the prioe appearing on this contract form. This assumes sound existing substr'uetures, superstructure and points of attachments- Extra labor or material incident to installation necessitated by defective substructures. superetructure3, points of attachment, or the moving of fixtures or appliances to be billed at extra cost to customer. DO NOT SIGN THIS CONTRACT UNTIL COMPLETE AND YOU HAVE READ THE TERMS AND CONDITIONS CONTAINED ON THE REVERSE SIDE OF THIS CONTRACT. BY SIGNING BELOW, YOU ARE ACKNOWLEDGING THAT YOU HAVE READ, UNDER- STAND AND AGREE TO THE TERMS AND CONDITIONS SET FORTH ON THE REVERSE SIDE OF THIS CONTRACT. YOU ARE ENTITLED TO A COPY OF THIS CONTRACT AT TVE TIME OF S;1VAvTU9E.eq WETNESS OUR HAND(S) AND SEAL(S) 13ELOW THIS 7 DAY OF /j/ J - WETNESS Seal) onager MarlsS;' R<Ai 7 T Labor'( Tax Total O Wheta spplic l rsoo le taxable: check local tax restttcdons. S L' VW& 11;:Y ti i1_C-t-t. C.l--ice (Seal) Owner ` Spouse Seal) rA! Itt Pf a +vuMt f%snlr vrt w+q e-+y*- .n ktNrilfMili',M+i d Ifj il( dpr lY t"!dawN tb4 t r+l• SI at* ytttllf stww MMuY IiR tltw)t e.tripet,y lnlrr , , M Mr14Lflfrt(+f of 'rilanllvro. /i rytrR. jpinW a - _ tatb— ay aob2t,ylciwP'e.t'1 6rvc's Ar1A the gib beSAirrsrs seg_vtwHd IraOn-n.rka r+t4Y Gor¢rn .- : _ . _ - _ 9otfoo (Rev. 7/02) FILE COPY Improving Home Improvement 8529 South Park Cr. Suite 430 Orlando, Florida 32819 Bus. 407/370-2872 Fax. 407/352-6309 Limited Power of Attorney Date:111-fqlo To: Building Department From: Rebeca Alicia Banuelos-Bernard I hereby name and appoint Nan Holmes, Mindy Holmes & Jackie Caines, a permit service for Lowe's Home Centers, Inc. to be my lawful atto 7ntoc r me and apply to for a permit for work to be performed at a location described as: Address of Job) Owner of Property) And to sign my name and do all things necessary to this appointment. Thank you for your assistance. Sincerely, e rReb—eca Alici-a Banuelos-Bernard Regional Installed Sales Manager Primary State Qualifier CRC 057468 Sworn to and subscribed before me this dayof Z '2004. i Ef; Rebecca Velez M1' COMMI SW# DD176963 EXPIRES 7anuary iz 1007 No. publiC My commission expires U P RP ,ellf3aRP117 T-e6j ORJCt *Y cir REVIpEROFSAN 4 r. l' MIAMIDADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Premdor Entry Systems 911 E. Jeferson, P.O. Boa 76 Pittsburgh ,KS 66762 MIAMI-DADE COUNTY, FLORIDA METRO -DADS FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 305) 375-2901 FAX (305) 375-2908 CONTRACTOR LICENSING SECTION 305) 375-2527 FAX (305) 375-2558 CONTRACTOR ENFORCEMENT DIVISION 305) 375-2966 FAX (305) 375-2908 PRODUCT CONTROL DIVISION 305) 375-2902 FAX (305) 372.039 Your application for Notice of Acceptance (NOA) of: Entergy 6-8 S-W/E Outswing Opaque Single w/sidelites Residential Insulated Steel Door under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined by BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the in V ACCEPTANCE NO.: 01-0314.21 / EXPIRES: 04/02/2006 Raul Kocinguez Chief Product Control Division THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dade County, Florida under the conditions set forth above. APPROVED: 06/05/2001 Francisco J. Quintana, RA. Director Miami -Dade County Building Code Compliance Office 11sN5o0 1*200011umplauslnotke acoepbnce cover page.dot Internet mail address: postmaster@buildingcodeonline.com l Homcpage:hftp://www.buildingeodconline.com Premdor Entry ystems ACCEPTANCE No.: 01-0314.21 APPROVED • JUN 0 5 '2011 EXPIRES ARM 02, 2006 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This renews the Notice of Acceptance No. 00-0321.23 which was issued on April 28, 2000. It approves a residential insulated door, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series Entergy 6-8 S-W/E Outswing Opaque Single Residential Insulated Steel Door with Sidelites- Impact Resistant Door Slab Only and its components shall be constructed in strict compliance with the following documents: Drawing No 31-1020-EW-0, Sheets 1 through 6 of 6, titled "Premdor (Entergy Brand) Wood Edge Single Door with Sidelites in a Wood Frames with Bumper Threshold (Outswing)," prepared by manufacturer, dated 7/29/97 with revision C dated 01/15/01, bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications of single door only, as shown in approved drawings. 4. INSTALLATION 4.1 The residential insulated steel door and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): 4.2.1 Door: the installation of this unit will not require a hurricane protection system. 4.2.2 Sidelite: the installation of this unit will require a hurricane protection system. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code SFBC) in order to properly evaluate the installation of this system. Qvl Manue rez, P.E. Product Con o xaminer Product'Control Division 2 Premdor Entry Systems ACCEPTANCE No.: ; 01-0314.21 APPROVED !JUN 0 5 2001 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South Florida Building Code affecting the cvaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. C. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer needs not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPT CE Ja Manuel erez, P.E., Product Coy!5TExaminerProdu&26fitrol Division 3 PREMDOR (ENTERGY BRAND) WOOD EDGE SINGLE DOOR WITH SIDELITES IN WOOD FRAME WITH BUMPER THRESHOLD 4' 4' NOTES 1) HOOD BACKS DT I PROPERLY TO TRANS 2) THE PRECEDING I QUALIFY THE FOLLOWING INSTALLATIONS.— A. WOOD FRAME CONSTRUCTION WERE DOOR SYSTEM IS ANCHORED TO A MINIMUM TWO BY WOOD OPENING, 1. MASRRY IR CONCRETE CONSTRUCTION WHERE DOOR SYSTEM IS AIADED TO A MINIMUM TWO BY STRUCTURAL WOOD BUCK. C. MASONRY OR CONCRETE CONSTRUCTION WHERE DOOR SYSTEM IS ANCHORED DIRECTLY TO CONCRETE OR BYMVDDQ itNIRWITHOUTAMUN-STRUCTURAL 3 ALL ANCHORING GGCSCREWS TO BE 110 WITH ION" 1 1/2' EMBEDMENT INTO WOOD SUBSTRATE Or 3/16' PFH TAPCOIS WITH 1 I/T MINIMUM EMBEDMENT INTO MASONRY. 4. WIT MUST BE INSTALLED WITH 'MIAMI-DADE COUNTY APPROVED' BUTTERS S THREE STAPLES PER SIDE JAMB INTO HEADER W SIDELITES AND Dot, THEE STAPLES PER JAMB INTO BASE W SIDELITES. L LATEX SEALANT 10 BE APPLIED AT SIDE 11 SIDE V V XK OUTSVIG LH IDTSVING 17?Si17 Q 1 1rTiN i 7>fTia• 1!'!:1'STTR T /: HPI71''i Bl]IT i>• v UNITS SWILL BE RSIAM ONLY AT LOCATIM PROJECTED IY A ENVY O DVEIDYBfi Ro Tim IE NW [IVIFN TIE EWE W FNO T OR OVERIM TO SILL IS LESS THIN 45 PEWEES. OLEA UNIT IS DSTNIEI IN TOM-MNIAu AREAS VIOIE ALE UNIT AND THE AREA ATE 13KKP TO AUNT VATER INTLMIKIN, 7. DOORMBELITE HEADER. DIIR/SIDELITE JAMBS, AND SIDELITE BASE COMERS ARE COPED AND BUTT .AIMED. 8 WIS SHNLL BE PIE -PAINTED WITH A VA1ER-BASED EPDXY RUST INHIBITIVE PRIMER PAINT WITH A OLT FLLN TMICINSS IF U TO 12 NL FRAMES SHILL BE PIE -PAINTED WITH AN ACRYLIC LATEX VATER-BASED/ VATER- REDUCIBLE WHITE PRIMER WITH A OILY FILM THICKNESS OF U TO 12 MIL JAMB INTO THRESHOLD APPFAMMASGOHipMNVAIH THE SOATIH BY 1 I MADM CODE UOSN/VOOOECOIrvUANCEOFFM ACCWDM ND pN- o3/V• Z I A Jtl, I IUIN A -A a U T S/ T n G OTHER CONFIGURATIONS GLAZING DETAIL I W 1 I V EXTERIOR GRADE LATEX CAULX EXTERIOR s• '•s ''i INTERIOR GLASS BITE 9 1/0' TEMPERED GLASS APPROVED AS COMPLrWG VATH THE SOLRNPOL'ON: NO COOS CAIAPLUNCE W ACCEPTANCE NO.0 i - 03 1 V • i. A' 1/4' SHIM MAX r 3/4' 80 11/16' MAX EXTERIOR 79 5/16' MAX SECTION B-B 2 BY WOOD BUCK 1 1/4' INTERIOR MATERIALS LIST DESCRIPTION IPART NUMBER COMMENTS IEAD JAMB I EW-12 11 1/4' X 4 9/16 U I ALUMINUM -BUMPER THRESHOLD EW-13 1PREMOOR BRAND OR EQUIVALENT - 1 1/4' x 4 9/16' TOP CHANNEL EW-OS PREMDOR BRAND - 1 11/16' - 20 GA STEEL 6 STEEL SKIN 26 go. (017 fml 0 a 16MMi of a ar 7PnLYuRFTHANr FoAm cORE BASF FOAM - DENSITY 2.0 TO 2.5 tbs./Ft' BOTTOM CHANNEL EW-06 1PREMDOR BRAND - 1 11/16' - 20 GA STEEL 97 vnnn I nrx RI nrx EW-08 4' X 9 1/2' MTL. TO BE PINE OR EQUIVALENT 4'x4' HINGE WOOD HINGE JAMB B10 x 3/4' F.H.W.S. 010 X 2' F.H.W.S. 7/16• PFH TNC 6 WNIMIMUIMI U SIDELITE WOOD STILE 08 x 2' F.H.W.S. LOCKSET 910 x 1 3/4' F.H.V.S 22' X 64' SINGLE PANEL GLAS! 1 1/4' SIDELITE TRIM (WOOD) VOOD CASING WOOD SIDELITE HEAD JAMB WOOD SIDELITE BASE POLYPROPYLENE LITE FRAME B6 X 1 1/2' PAN HEAD SCREWS PIN NAIL DOW SILICONE #995 APPRdMAS COMPIYRIG YgM THE SOUTH FLOEB)A GUILINNra(9DE Pao el(TMaomaoM 911 E• BUILDING CODECOMPUAROE3w, PIII$ ACCEPfANCENo CI-o. Ury MLMUUR OMMNU - JUJU -11I - -L. lU Or 'UL•L-LL L HAGER BRAND HINGE OR EQUIVALENT - .097 THICK (STEEL) 1 1/4' X 4 9/16' MTL. TO BE PINE OR EQUIVALENT 4) SCREWS PER HINGE INTO DOOR 6) SCREWS Twww EACH SIDELITE JAMB INTO SIDELITE. 4- DOWN FROM P MAX S' O.C. TVI REAITER REFER TO ELEVATION VIEW, FM I OF SCREWS USEO AND LOCATIONS EV-07 15/16' X 1 11/16' MTL. TO BE PINE OR EQUIVALENT 2) SCREWS AT EACH STRIKE PLATE KVIKS T BRAND 200 LOCK OR HARLOC BRAND 100LUCK S) SCREWS THRM HINGE JAMB INTO SIDELITE JAMB, B' DOWN FROM TOP, MAX IS' O.C. TIV REAFIER ID) SCREWS TMRQIGN STRIKE JAMB INTO SIDELITE JAMB, 4' DOVN FROM TOP MAX B' O.C. THEREAFTER 4) SCREWS THROUGH EACH HINGE INTO DOM JAMB V-18 1 1/4' X 4 9/16' MTL. TO BE PINE OR EQUIVALENT V-19 A N Y A - - -) W-20 5/16 x 1/2' MTL. TO BE PINE OR EQUIVALENT W-21 FOR SIDE IY SIDE JAM IS' AS MULLIONSN M U W-22 1 1/4' X 4 9/16' MTL. TO BE PINE OR EQUIVALENT W-23 1 1/4' X 4 9/16' MTL. TO BE PINE OR EQUIVALENT 1643, OBL-2 HP Polypropylene by ODL 18 PER FRAME x 4 TN ANF Ea* 7RR CORNER AND NOT 3/4' LONG MIL. 4' IN FRDN END. MAX B' GC THERAFTER, USED ON MULLIO S MIT TRIM 1-1020-EW-0 SHEET 3 OF 6 . REVISION IETIER g 2 BY WOOD BUCK 1/4' SHIM MAX 3/4' n J- INTERIOR I - 80 11/16' MAX 2 BY WOOD BUCK SECTION C-C 1 1/4' EXTERIOR PLEASE SEE 'GLAZING DETAIL' DRAWING #31-1020-EW-0 SHEET 2 OF 6 1 1/4' DOW SILICONE 4995 APPROVED AS COMPLYING YYOH THE SOUTH PLpgIL11 q ll{DI1 j E . er YII U 7 'U oPRoo oLomawN CODECOMPUANCEOFFlCE ACCEPTANCE NO_!#"S_IV. si 10 OTHER DOOR CONFIGURATIONS XE 0PROK0AS COMPLYING WTH THE ACCEPTANCEN0.01- 43IV. a, X OTHER DOOR PANEL STYLES 36' 1 I, -MAX 79 /17oo 0 000 0o a°oo 00 a00 LI go MAC_ 00 00 00 00 00 ooa °a°a ® 000 Dorto0 0o ao BLANK TOP 6-PANEL 4-PANEL 9-PANEL 10-PANEL 18-PANEL FLUSH 8-PANEL CROSSBUCK 12-PANEL 4-PANEL 5-PANEL 5-PANEL 5-PANEL 5-PANEL 4-PANEL EYEBROW V/SCROLL EYEBROW EYEBROW V/ SCROLL OTHER SIDELITE STYLES 30' 1 IFMAX 79 / 16' Q Qal Mix SL- 10 SL-20 SL-30 SL-60 SL-50 SL-508 SL-69A SL-690 SL-69C SL-25 SL-53 SL-300 SL-40 SL-90A SL-908 SL-90C SL-300 SL-30C SL-70 SL-80 0o Do s ®aoao0III9aIaI@ 00 01 oo as ao 00 00 PO-1 PO- 2 PO-3 PD-4 PO-5 PO-6 PO-7 PO-6 PO-9 PO-10 PO-11 PO-12 PD-13 PO-14 PO-15 PO-16 PO-17 a I'M, 9 9 PO-16 PO- 19 PD- 20 PD-21 PO-22 PD-23 PO-24 PO-25 PB-26 PO-27 PO-28 PO-29 PO-30 PO-31 PO-32 PO-33 PO-34 3 8 Ell 011 UtISI It lag 000 090 g60 0 D O MPLRMI Y f PR M 0 PfIONS 00 00 0 ooa oao aoo 0o ao M R BOY Y M 31-1020-EY-0 PO-35 PO-36 PO-37 PO-36 PO-39 PD-40 PO-41 PO-42 PO-43 PO-434 PO-438 I corRm762 SHEET 6 OF 6 IEVIS1011 allu Florida Building Code Online Page 1 of 2 rA ra a • i .t y 'r_-.r , fir,. Y„,,,A, iil f ' y ti ' , 1. • r .ice K Y S t. fR nY i-• 'C r r r r Overriew. Product Search Organization Product ' Search ication 3Cc :•' s ' e. a s S Sf: k"tL:Yc hl N R7t."3..u•. "' M21=s26-11=11 User: Public User - Not Associated with Organization - Need Help Application #: FL19 Date Submitted: 08/04/2003 Product Manufacturer. Masonite International Address/Phone/email: One North Dale Mabry Suite 950 Tampa, FL 33609 L0 I l Technical Representative: Steve Schreiber Technical Representative Address/Phone/email: l Premdor Drive Dickson, TN 37055 615)4411-4258 sschreiber@masonite.com Category: Exterior Doors Subcategory: Swinging Evaluation Method: Certification Mark or Listing Reference d.Standards from the Florida Building Code:., Section..., tandard..Year TAS201•. 1994 TAS202 1994 M I TAS203 1994 Certification Agency: Intertek Testing Services - ETL/Warnock Hersey Quality Assurance Entity: Validation Entity: Authorized Signature: Steve Schreiber sschreiber@masonite.com Evaluation/Test Reports Uploaded: Installation Documents Uploaded: http://www.floridabuilding.org/pr/pr detl.asv?IPT=19&fin=ROSrch' 8/2/2004 Florida Building Code Online Product Approval Method: Application Status: Date Validated: Page: Go ti Page 2 or 2 Method 1 Option A Approved 08/ 112003 Page l / l pp/Se roduct Model # or Nameletal-Edge Model Description Limits of Use 11 ] Steel Door Units None Known Next _ s:i'%.',5€.'ud"".-.sdY.0 a.'$.`"7'r;..ti'c.F '$Y%::X"'C.'s.L';.'IT.:.'sY".. .z".YlLc3&vii. `r.n a;:.: L`.:+k::s s. s'irsiP3?'e`mi;::ea-i?':.':sw'i•'Vti: a'r.i• .:.+%'r st Cil id:.°..'Yc..Y :a-s r.• ...'h.'-Sr.^.':...: 1 _ Copyright and Disclaimer. 02000 The State of Florida. All rights reserved. IYt s!i............. Jw i