Loading...
HomeMy WebLinkAbout114 W First StREVISIONS PERMIT # E?Co RECE/LSD AN 10 ?006 DATE 1I10I06 ADDRESS 9 l-4 wt"C-)T 'F(F)ST STIWJ CONTRACTOR Fli:rr,—Ti<01\iCGS It TdJC PH # 'eADl --I 7i — (09 ©O Wl WK'Pr 1)ctILDINC; FAx # 4m`1--7 -74 -zo74 DESCPRITION OF REVISION: ADD RELAY UTILITIES FIRE BLDG FIRETRONICS, INC. FIRETRONICS EXTINGUISHERS, INC. 1035 PINE HOLLOW POINT DR. ALTAMONTE SPRINGS, FL. 32714 PHONE (407) 774-6900 * FAX (407) 774-2074 PERMIT #Liaok-%.tv PLANS REVIEWED CITY OF SANFORD FIRE ALARM REVISION #1 FOR ORLANDO SENTINEL 114 WEST FIRST STREET WELAKA BUILDING O,cF CF FIRETRONICS, INC. FIRETRONICS EXTINGUISHERS, INC. 1035 PINE HOLLOW POINT DR. ALTAMONTE SPRINGS, FL. 32714 PHONE (407) 774-6900. FAX (407) 774-2074 TO: CITY OF SANFORD FROM: MARK STEPHENSON DATE: 1 /9/06 PERMIT # 06-813 THIS IS TO INFORM YOU OF CHANGES TO THE FOLLOWING LOCATION: ORLANDO SENTINEL 114 WEST FIRST STREET WELAKA BUILDING THE CHANGES ARE AS FOLLOWS: 1. ADD 2-DUCT DETECTORS 2. ADD 1-RELAY 3. DEMO ]-HORN STROBE IF YOU HAVE ANY QUESTIONS OR COMMENTS, PLEASE DON'T HESITATE TO CALL ME. THANK YOU FOR YOUR HELP. SINCERELY, MARK STEPHENSON Drafting Dept. Firetronics, Inc. 1035 Pine Hollow Point Dr. Altamonte Springs, FL. 32714 Ph: 407-774-6900 / fax: 407-774-2074 mstephenson(@firetronics.com 1035 Pine Hollow Point Dr. DATE 01 /09/06 FIRETRONICS phone (407) 774-6900 / fax 774-2074 ORLANDO SENTINEL 114 WEST FIRST STREET WELAKA BUILDING EXISTING FACP x = DEVICES DRAW TOTAL 2 > DH100ACDCI / DUCT DETECTOR 21 0.0151 0.03 1 > CRF-300-61 RELAY MODULE 11 0.001451 0.00145 01 01 0 01 01 0 01 01 0 01 01 0 01 01 01 01 01 0 x = DEVICES I DRAW I TOTAL 2 > DH100ACDCI / DUCT DETECT 21 0.071 0.14 1 > CRF-300-6 7 RELAY MODULE 11 0.0321 0.032 01 01 01 01 0 01 0 01 0 01 0 01 0 Altamonte Springs, FI. 32714 A.C.P./ SIGNAL EXPANDER CALC'S. IN #1 T PANEL = 0 AMPS (PANEL ONLY) 0.1175 AMPS (EXISTING SYSTEM) 0.03145 AMPS (NEW DEVICES) 0.14895 AMPS (ALL DEVICES) x 24 HOURS SUPERVISORY 3.5748 TOTAL AMP HOURS (SUPV.) BACKUP GENERATOR: INO STATUS: ICHANGED PANEL = 0 AMPS (PANEL ONLY) 2.066 AMPS (EXISTING SYSTEM) 0,172 AMPS (NEW DEVICES) 2.238 AMPS (ALL DEVICES) x 0.0833 HOURS ALARM (5 MINUTES)* 0.186425 TOTAL AMP HOURS (ALARM) 5 MIN = .0833 / 15 MIN = .2499) J SUPERVISORY CURREN, 3.5748 OJ ALARM CURRENT 0.186425 TOTAL COMBINED AH REQUIRE 3,761225 01MULTIPLY BY THE DERATING FACTO 1.2 MINIMUM BATTERY AH REQUIRE 4.51347 01 BATTERY CAPACITY PROVIDE[ 7 rr 1035 Pine Hollow Point Dr. DATE 01 /09/06 x = DEVICES I DRAW I TOTAL 01 01 0 01 01 0 01 01 0 01 01 0 01 01 0 F I R ET RO N I C S Altamonte Springs, FI. 32714 phone (407) 774-6900 / fax 774-2074 ORLANDO SENTINEL F.A.C.P./ SIGNAL EXPANDER CALC'S. 114 WEST FIRST STREET WELAKA BUILDING EXISTING SIGNAL EXPANDER REVISION #1 SUPERVISORY CURRENT STATUS: INO CHANGE PANEL = 0 AMPS (PANEL ONLY) 0.075 AMPS (EXISTING SYSTEM) 0 AMPS (NEW DEVICES) 0.075 AMPS (ALL DEVICES) x 24 HOURS SUPERVISORY 1.8 TOTAL AMP HOURS (SUPV.) 01 01 0 01 01 0 01 01 0 01 01 0 x DEVICES I DRAW I TOTAL 5 > NS-24MCW / HORN STROBE 75cd 51 0.1291 0.645 LESS 1 > EXISTING HORN STROBE 75cd 11 0.129 0.129 01 01 0 01 01 0 01 01 01 BACKUP GENERATOR: INO ALARM CURRENT PANEL = 0 AMPS (PANEL ONLY) 1.609 AMPS (EXISTING SYSTEM) 0.516 AMPS (NEW DEVICES) 2.125 AMPS (ALL DEVICES) x 0.0833 HOURS ALARM (5 MINUTES)- 0.177013 TOTAL AMP HOURS (ALARM) 5MIN =.0833/15MIN =.2499) SUPERVISORY CURREN' 1. 01 01 01 ALARM CURRENT 0.17701 TOTAL COMBINED AH REQUIRE 1.97701 01 01 01MULTIPLY BY THE DERATING FACTO 1, MINIMUM•BATTERY AH REQUIRE 2.37241 01 01 01 BATTERY CAPACITY PROVIDES 01 01 01 01 01 01 Model DH100ACDCI 4-Wire Ionization Duct Smoke Detector Product Overview Air velocity rating from The System Sensor Innovair" DH100ACDCI is a 4-wire ionization air duct 500 to 4000 feet per minute smoke detector capable of sensing smoke in air velocities from 500 to 4,000 2.54 to 20.32 m/sec.) feet per minute (2.54 to 20.32 m/sec). This detector was developed to Patented intereonneetablllity for multi- constantly monitor the air within a duct and to detect the presence of smoke. fan shutdown (up to ten air handlers) Patented telescopic sampling tube The two available form C relay contacts provide reliable performance for the management of fans, blowers and air conditioning systems. These HVACPatentedcovertampertroublesignal devices can be configured to prevent the spread of toxic smoke and fire gasses 24 VAC/DC or 120/240 VAC operation through a protected area High -Low voltage barrier Equipped with two DPDT Form C relay contacts Built -In reset button Outside mountinb tabs Easy and quick mounting to round or rectangular ducts from 1'-12' 0.3-3.7 meters) wide Easy to clean UL recognized field -replaceable power and sensor boards Remote test station option Remote sounder option UL 268A listed 3-year warranty Photoelectric model available LISTED The Innovair family is designed for simplified installation and easy mainte- nance. The modular construction allows for easy cleaning and uncomplicated field replacement of the UL recognized power and sensor boards. The patented cover missing feature insures the cover is securely tightened following routine cleaning and maintenance. The patented interconnectability feature alloys mul- tiple Innovairs to communicate with each other. In the event smoke is detected, the Innovair will signal the remaining interconnected detectors to initiate their relays for smoke control. WARNING: Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's rei;ular fire 1Zefer to NFI'A 72 and 90A for additional information about the proper application of duct smoke detectors. Electrical Ratings — DH100ACDCI (Includes Detector) Power supply voltage: 20-29 VDC 24 VAC 50-60-Hz 120 VAC 50-60 Hz 220/240 VAC 50-60 Hz Input capacitance: 270 NF max. 270 f/F max. N/A N/A Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. 20 VAC min. Reset time (with RTS451): 03 to 0.3 sec. 03 to 0.3 sec. 03 to 0.3 sec. 03 to 0.3 sec. Reset time (by power down): 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 34 sec. max. 34 sec. max. 34 sec. max. 34 sec. max. Alarm response time: 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. Sensitivity Test: See detector label See detector label See detector label See detector label Power Supply Voltage 20 - 29 VDC 4 VAC 50 - 60 Hz 120 VAC 50 - 60 Hz 2201240 VAC 50 - 60 Hz CURRENT REQUIREMENTS (USING NO ACCESSORIES) Max. Standby current 15 mA 35 mA RMS 25 mA RMS' 15 mA RMS' I Max. alarm current I 70 mA 125 mA RMS 35 mA RMS' 25 mA RMS' CONTACT RATINGS Alarm initiation contacts (SPST) 2.0A @ 30 VACIDC (0.6 power factor) ACCESSORY CURRENT LOADS AT 24 VDC Alarm auxiliary contacts oPDT) 10A @ 30 VDC 1OA @ 250 VAC Note: Alarm auxiliary contacts must switch 100mA minimum at 5VOC. Alarm auxiliary cortacts shall not be connected to inititaing circuits of control panels. Use the alarm initiation contact for his purpose. DEVICE STANDBY TROUBLE ALARM APA451 . 12.5mA Max. n/a 3OmA Max. PA400 OmA Iva 15mA Max. RA40OZ OmA Na IOmA Max. Trouble contacts (SPDT) 2.OA @ 30 VDC (resistive) RTS4511RTS451KEY 12mA' Na 7.5mA Max. SSK451 5mA Max. OmA Max. 3OmA Max. Wiring diagram for DH100ACDCI to APA451 DH100ACDCI Alarm Signal Aux. Power + Sup. N. O. Sup. COM Aux. Power — APA451 Alarm Power Common NOTE: Wiring diagram shown is for DH100ACOCI 4-wire duct smoke detector system equipped without a control panel. NOTE: A trouble condition is Indicated when the green LED is not illuminated. Wiring diagram for DH100ACDCl to SSK451 and interconnect feature FIELD INSTALLED JUMPER FOR TEMPORAL PATTERN COMMON, TEMPORAL SELECT ALARM SIGNAL SUPERVISORY SIGNAL RESET TEST POWER(—) POWER (+) ALARM SIGNAL SUPERVISORY CONTACT RESET TEST AUX.POWER(—) AUX. POWER (+) INTERCONNECT + INTFRCONNFOT — UNiI 1 FIELD INSTALLED/ JUMPER 12 UNIT 2 INTERCONNECT+ 1 INTERCONNECT — OH100ACDC1 Coil Note: Please note that the magnetic coil supplied with the RTS451/RTS451KEY Is not required when these accessories are used with the DH10O detectors. The functionality of the magnetic coil has been designed into the circuitry of the Innovair duct smoke detectors. NOTE: When a unit is powered at the 120VAC or 2201240VAC Input, any combination of accessories may be used such that the given accessory loads are: 60 mA or less in the standby state; 110 mA or less In the alarm state. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered with the same, independent supply. Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit 1 to terminal 12 on unit 2 and so on. Similarly, connect terminal 1 on unit 1 to terminal 1 on unit 2 and so on. Wiring diagram for the RTS451/RTS451KEY and interconnect feature DH100ACDCI RTS451/RTS451KEY Alarm Signal 15 1 (Red LED) Alarm l— — — — — — Aux, Power + 19 I* 6 (Green LED) Sup. N. O. 14 I Power I I Sup. COM 3 I Aux. Power— 20 Reset Test Interconnect — NOTE: For RTS451 KEY only without a Control Panel. DH100ACDCI RTS451 does not have a terminal 6. UNIT 2 NOTE: Wiring diagram shown is for Interconnect— 1 DH100ACDCI 4-wire duct smoke detector system equipped Interconnect + without a control panel. 12 NOTE: A trouble condition is Indicated when the green LED is not Illuminated. March 13, 2003 DF-52374 • E-930 FI re-LITe®ALarms CRF-300-6 I Six -Relay Control Module www.firelite.com Section: Addressable Devices GENERAL Fire-Lite's CRF-300-6 six -relay control module provides an intelligent alarm system with six Form-C relays. The first module is addressed from 01 to 154 while the re- maining modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of three unused modules. A single isolated set of dry relay contacts is provided for each module address, which is capable of being wired for either a normally -open or nor- mally -closed operation. The module allows the control panel to switch these contacts on command. No supervision is provided for the controlled circuit. Each CRF-300-6 module has panel -controlled green LED in- dicators. The panel can cause the LEDs to blink, latch on, or latch off. FEATURES Six addressable Form-C relay contacts. Removable 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2) plug- in terminal blocks. Status indicators for each point. Unused addresses may be disabled. Rotary address switches. Mount one or two modules in a BB-X2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-2F cabinet (optional). Mounting hardware included. SPECIFICATIONS Standby current: 1.45 mA (SLC current draw with all ad- dresses used; if some addresses are disabled, the standby current decreases). Alarm current: 32 mA (assumes all six relays have been switched once and all six LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C). Humidity: 10% to 85% noncondensing. Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.0" (25.40 mm) deep. Shipping weight: 1.1 lb. (0.499 kg) including packaging. Wire gauge: 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2). Maximum SLC wiring resistance: 40 or 50 ohms, panel dependent. Maximum IDC wiring resistance: 40 ohms. Relay current: 30 mA/relay pulse (15.6 ms pulse duration), pulse under panel control. Relay contact ratings: 30 VDC; 70.7 VAC. UL F M LISTED APPROVED S3705 California State Fire Marshal 7300-0075:205 M EA 55-02-E Current ratings: 3.0 A @ 30 VDC maximum, resistive, non -coded. 2.0 A @ 30 VDC maximum, resistive, coded. 1.0 A @ 30 VDC maximum, inductive (UR = 2 ms), coded. 0.5 A @ 30 VDC maximum, inductive (UR = 5 ms), coded. 0.9 A @ 110 VDC maximum, resistive, non -coded. 0.9 A @ 125 VAC maximum, resistive, non -coded. 0.7 A @ 70.7 VAC maximum, inductive (PF = 0.35), non - coded. 0.5 A @ 125 VAC maximum, inductive (PF = 0.35), non - coded. PRODUCT LINE INFORMATION CRF-300-6: Six -relay control module. This document is not intended to be used for installation purposes. We try to keep our product IS09001informationup-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. 9YOIIIEERII 8 MANOfAL1UtRllliPhone: (800) 627-3473, Toll -Free FAX: (877) 699-4105. 6926wirl ..mf WIRING DIAGRAM FROM PANEL OR PREVIOUS DEVICE COMMUNICATION LINE, 32 VDC MAXIMUM. SEE PANEL MANUAL FOR WIRE REQUIREMENTS. TO NEXT r VICE m 1 O ADDRESS DISABLE NONE ONE TWO THREE Page 2 of 2 — DF-52374 • 03/13/03 1alat;11/11YnJkJfJt:7iaiilin® Power - Limited/Unshielded DESCRIPTION Plenecon IIO Extra Flexible • ASTM bare copper FPLP Polymer alloy insulation Twisted pair or cabled construction Polyester binders as required • Flexible plenum jacket11n_ RATING UL listed NEC type FPLP Constructed in accordance with UL Standard 1424 Complies with UL 910 test modified ASTM Steiner Tunnel Test Meets 300 volt requirement as specified in Section 760 of the NFC APPLICATIONS Indoor (non -conduit per NEC) within ducts, plenums, and other spaces used for environmental air for: Audio circuits Control circuits Initiating circuits Notification circuits SPECIAL NOTES Capacitance of unshielded cable may vary depending on the installation environment. INSTALLATION PRECAUTIONS for plenum cable: refer to the Technical Reference Section 54-WEST PENN WIRE/CDT Catalog of Stranding Insulation Thickness Nom. O.D. Capacitance D.C.R. inch mm inch mm inch mm pf/ft' pf/m` 60980B 1 18 Solid 010 25 015 38 142 3.61 29 95 Pair 6.5 92/M' 60982B 4 18 Solid 010 25 015 38 175 4.45 29 95 4M 6.5 S2/M' 60991 B 1 16 Solid 010 25 015 38 161 1.09 32 105 Pair 4.1 S2/M' 60164B 4 16 Solid 010 25 015 38 220 5.59 32 105 4.1 OX 60993B 1 14 Solid 012 30 015 38 191 4.86 35 115 Pair 2.6 nX 60700B 4 14 Solid 012 30 015 38 252 6.40 35 115 2.6 S2/M' 60995B 1 12 Solid 012 30 015 38 225 5.72 45 148 Pair 1.8 S2/MI Standard spool size 1000 feet 'Capacitance between conductors. COLOR CODE 1. Black, 2. Red, 3. Brown, 4. Blue JACKET: Red