Loading...
HomeMy WebLinkAbout1215 French AveAndrew Kutz Architect AR 0006491 2019J'outh Park Avenue Janford. rbridq 32771 Omnefiox (407) 322-3853 dwtz0cff.rr c= 1/4nOO5 ADDENDUM 2 To: Sanford Building Department akS Project: AOK TFrench Avenue, Sanford, 32771 Owner. Mr DG Williams Jr Tax Id: 25-19-30-5AG-1408-0010 Contractor: Conrad Constriction Inc. PO Box 470424 Lake Monroe, Florida 32747 PROJECT ADDENDUM (2) This following information is hereby issued and is to take precedence over all previously released drawings and specifications, and shall attach to the project drawing as if contained therein integrally: 1) Two footings are increased to accommodate shop drawing addition of 2 columns. They were D footings which have been increased to A footings. 2) Three C footings are reduced slightly in overall size. Changes are flagged as R2 on the attached revised drawing: A-1, R2 IANS RI'!!EW7.r) CITY fz i An Kutz Architect AR 0006491 1/4/2005 r „ cc: AOK-Tire Conrad Construction r--------- ---- I I FOUNDATION NOTES ALL CONCRETE SHALL BE MINIMUM 3000 PSI AT 28 DAYS ALL FILL SHALL BE COMPACTED TO 95% OF MODIFIED PROCTOR O 14% MOISTURE ALL REINFORCING STEEL SHALL BE #5 OR GREATER. GRADE 60 DEFORMED STEEL ALL REINFORCING STEEL IS TO HAVE A MINIMUM OF 3 INCH CONCRETE COVERAGE ALL REINFORCING STEEL JOINTS SHALL LAP A MINIMUM OF 40 BAR DIAMETERS OR 25 INCHES WHICHEVER IS GREATER VAPOR BARRIER SHALL BE 6 MILL POLYETHYLENE THE FOUNDATION HAS BEEN DESIGNED FOR A SOIL BEARING CAPACITY OF 2600 PSF, THE COMPACTED SOIL SHALL BE VERIFIED BY A GEOTECHNICAL TESTING LAB ALL LUMBER IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED ALL FILLED CELL MASONRY SHALL BE GROUTED AND POURED IN MAXIMUM 8 FOOT LIFTS CJ = SAWCUT 1/8' X 1 1/2' DEEP WITHIN 24 HOURS OF CONC POUR FOOTING SCHEDULE ID SIZE REINFORCING A 72x72x16 506"EA WAY B 72X72X16 506"EA WAY C 84X84X16 506"EA WAY D 24X24X16 506"EA WAY E 16 X 20 DEEP 2 - #5 CONTINUOUS F 16 X 8 DEEP 2 - #5 CONTINUOUS G 8X8 I - # 5 CONTINUOUS L_J k i NOTE: THERE IS AN 8'-0' HIGH REINFORCED MASONARY INSTALL * 5 VERTICAL REBAR E 1 MAX 4' OC. SEE CROSS SECTION DRAWING A4. CO-ORDINATE WITH DOOR OPENINGS - SEE PLAN A2 FOR SPECIFIC VERTICAL B REINFORCMENT IN ADDITION f ---F--T"-or,Rw4RCh1ENT------ r------ 1 C I I L----- 1 I IE I 5" CONCRETE SLAB WITH I 6x6-10/10 WWF ON MIN 6 L__ MILL VISOUEEN OVER B POISONED COMPACTED FILL 14 A E r-, C--- `--------------J r------------------------r - G -----4' SLAB I L----------------------------- SLOPE FLOOR I E DOWN AT ALL I A II OVERHEAD L__1__-1 DOOR OPNGS I R2 I I 1 1 , I 1 I C I R2 I I fit '---------- I -t I C I I I I I I I C i R2 Re' I AI E ' ' j I L_ _. 10'-0• ji FOUNDATION 3/32- 2 1'-0- E 1 , r------------- --= - -- L_J , D E A ,' 1 HAIRPINS• MAKE FROM TWO CONTINUOUS 20 FT E 05 REINFORCING STEEL BUNDLED TOGETHER B-} L-----' I I I I E' I I El I I 1 r----- B-j L----- i El I I E AI r- _ I ---------------- J--- EXISTING POWER POLE G I I I J ti A R2'''' JANUARY 4, 2004 A09 Svmffxjc a W O W_ Z Lu NW W O 1 a V