Loading...
HomeMy WebLinkAbout122 Walnut Crest Runa RECEIVED CITY OF SANFORD PERMIT APPLICATION Permit #: NO " 1 3 I ( J A N 3 0 2006 p Job Address: Z ' n 6l, G'eS K—Vl SA A) Fz rDpte: Z 77 Description of Work: _ - eP..1L e. $ 2 Historic District: Zoning: Value of Work: S L43 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: q # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: 1 ---3— Z — ttach Proof of Ownership & Legal Description) Owners Name & Address: 1 r3 ti Vt Y" ( P r.4 U 1 Contractor Name & Address: OSUMmomm p_p p State License Number: LfoC QD ' 00% Phone & Fax: 417! %4 D— t /M Contact Person: I,Gt1IN JO hAS Phone: yD% oyg'T7Y) Bonding Company: Address: Mortgage Lender: Address: Address: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. .I understand that a separate . permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. u NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of per s)tefific )(001y(vill notify the owner of the property of the Stoatuie of Owry'r/ Arri Date r t., o /k—'o J. Rw, JR. ION t DD 192438 APPLICATION APPROVED BY: Bldg: , ' V' Zoning: Utilities: Initial & Date) (Initial & Date) Special Conditions: 00 FD: Initial & Date) (Initial & Date) r11*1 In na It Eel a on, . arw q1 i1 Jli it ill it ili N1 ill is iiNi 0 MARYANNE MORSE, CLERK OF CIRCUIT COURT EMINOLF, ;OUNTY-- llili Instruinc t 1're ated Dy: - . BK ' 06100 PG 1261 i!arne CLERK'S # 2006015482AOdrectG RECORDED 01/30/4006 03129:34 PML RECORDING FEES i0.007l RECORDED BY D Thooas CERTIFILD COPY MARY-IIVNF. MORSE CLE".OF..CI r COURT 1'cntiit No. SE OLE' CO FLORID/ NO110E OF COMMENCEMENT t3Y FPr.ITM Ct.E STATE OF El or ,da _ '4N 3 0 2006COUNTYOF ;P_ "note A V t (U , THE UNDERSIGNED hereby.gives notice that Improvement will be n:nde to certain real property, and in accordance with Cliapter 713, Florida Statutes, the following Informations provided In thisNoticeofCommencement. 1. Description q property: (Icgnl description of property, and street address If available) Clr7tG/ Sl J cS-at^v F- be- ("ter? ro- / P19f- rbcije_ (p 2 f PJ' l -z —/Y— 12 2 t l I n I.l - C r s— 2vt • S A,jF-a .-j r—(, 3 Z 7.7 1 --k-&7fAc h e G Jh 2. General description of improvement: SCREEN ENCL'OSURt 3. Owncr. info rinnlinn -Fo I) 0 cell ( A-" r 1 •e C'.4V, a: Nance and address: 122 1,) nk — .C'- „; ,fur-P(, >?77 / b. Interest in property: Owner/Bui l der C. Name and address of fce simple titleholder (if other than owner): 4. Contractor: (name and address) Action Aluminum 2698- S. Orange Blossom Trail Orlando, FL 32805- 5. Surcly a. Nnmc and address: b. Amount of bond $__._ AM 6Acndcr. ( name and Uddress) 7.' Pcrsons within the State or Florida designated by Owner upon whom notices or other docuniculs may be served as provided by Section 713.13(1)(a)7., Florida Statutes: manic acid address) AN. 8. In addition to himself, Owner designates the following person(s) to.receive a copy of.thc Licnor' s Notice as provided In [Scn Ilion 713.13(1)(b), Florida Statutes: (name and address) fV 9. I'xpirntioin tints of notice of commencement (tilt: expiration dnte Is 1 year from the date of recording unless n different date is specified) Swnrn to niul•suhscribed before me this W7 dny of &--- za ' Si urc of Owner' Owner s Nome o Signallue of bufuly 1'6W) 0wncr' s Address 12 7— Notary' s Name J. i;APP, JR. _ cJZ c, 't X ( I Z 7 -7 / Notary' s Commission F.x _ 1$$It)NIDu1-9 March 11. W. State of Florida, "°"a` The foregotn In t nt wa 7acknowledgedbefotsCdate) liy_Ow—'T name of,person acknowledging), wlio is we vnall` 112-0 t to me or has producrd type of ldentl'Pi oti as 'ldent I f ic,t tun and who ACTION ALUMINUM PRODUCTS, INC 2698 South Orange Blossom Trail Orlando, Florida 32805 POWER OF ATTORNEY I hereby name and appoint Patty Johns to be my lawful attorney, in fact to act for me and apply to4he =a led Building Department fora 001- scr en Env clos raze permit to be performed at a location described as: a AMLNur Ce esr Attxl And to sign my name and do all things necessary to this appointment. pe-- - David Allan J has CGC 053605 SUBSCRIBED BEFORE ME THIS 2-3 DAY OF 20j2k Notary as to Con ractor My Commission DAMELTHOMP80N COMMISSION # DD 255104 EXPIRES: Ogober 1, 2V ow" Thu N01dy PkA* unarwlun METRO ORLANDO (407) 648-9948 • Fax (407) 648-9949 9 BREVARD (407) 632-0264 9 VOLUSIA (904) 252-7835 Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 PARCEL DETAIL M k k , lei DAvin Jommsom. CFA,ASA PROPERTY' APPRAISER ___ Im SEMINOLE COUNTY Ft-- is 1101 E. FiRsT sT 3A 9'- sA![FORo, FL32T71-14C 4D7-665-75D6 7 1 9/ a 2006 WORKING VALUE SUMMARY GENERAL Value Method: Market Parcel Id: 22-19-30-502-0000-0950 Number of Buildings: 1 Owner: CAVITO TODD C & LAURIE D Depreciated Bldg Value: $137,292 Mailing Address: 122 WALNUT CREST RUN Depreciated EXFT Value: $0 City,State,ZipCode: SANFORD FL 32771 Land Value (Market): $29,500 Property Address: 122 WALNUT CREST RUN SANFORD 32771 Land Value Ag: $0 Subdivision Name: PRESERVE AT LAKE MONROE Just/Market Value: $166,792 Tax District: S3-SANFORD-WATERFRONT REDVDST Assessed Value (SOH): $166,792 Exemptions: 00-HOMESTEAD Exempt Value: $25,000 Don 01-SINGLE FAMILY Taxable Value: $141,792 Tax Estimator 2005 VALUE SUMMARY Tax Value(without SOH): $2,843 SALES 2005 Tax Bill Amount: $2,843 Deed Date Book Page Amount Vaclimp Qualified Save Our Homes (SOH) WARRANTY DEED 09/2004 05475 1455 $195,000 Improved Yes Savings: $ 0 Find Comparable Sales within this Subdivision 2005 Taxable Value: $142,486 DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS LAND LEGAL DESCRIPTION Land Assess Frontage Depth Land Unit Land PLATS: Pick... Method Units Price Value LOT 95 PRESERVE AT LAKE MONROE PB LOT 0 0 1.000 29,500.00 $29,500 62 PGS 12 - 15 BUILDING INFORMATION Bid Year Base Gross Living Est. Cost Bid Type Fixtures Ext Wall Bid Value Num Bit SF SF SF New 1 SINGLE 2004 9 1,042 2,938 2,476 CB/STUCCO $137,292 $138,679FAMILYFINISH Appendage I Sqft OPEN PORCH FINISHED / 21 Appendage / Sqft GARAGE FINISHED / 441 Appendage I Sqft UPPER STORY FINISHED / 1434 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished,Base Semi Finshed NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www.scpafl.org/pls/web/re web.seminole county title?parcel=22193050200000950... 1/25/2006 PLAT 4F SURVEY DESCRIPTION: (AS FURNISHED) LOT 95, PRESERVE AT LAKE MONROE AS RECORDED IN PLAT BOOK 62, PAGES 12-15 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA NOTE: THE FINISHED FLOOR ELEVATION OF THIS STRUCTURE MEETS OR EXCEEDS THE THE REQUIREMENTS SET FORTH IN THE CITY OF SANFORD CODE CHAPTER 6, SEC. 6-7(A). CERTIFIED TO AND FOR THE EXCLUSIVE USE OF: COMMERCE TITLE COMPANY COMMERCE TITLE INSURANCE COMPANY CTX MORTGAGE COMPANY, LLC LEGEND BUILDING SETBACK LINE CENTERLINE RIGHT OF WAY LINE 0 EXISTING ELEVATION CONCRETE LB LAND SURVEYING BUSINESS LS LAND SURVEYOR PRM PERMANENT REFERENCE MONUMENT PCP PERMANENT CONTROL POINT P) PER PLAT M) MEASURED FND FOUND C/W CONCRETE WALK S W SIDEWALK C CONCRETE PAD CS CONCRETE SLAB C CHORD LENGTH PK PARKER KALON R RADIUS POC POINT OF CURVE FND 1/2'[RON ROD AND CAP LB #6393 (08-24-D4) QFND NAIL AND DISCLB168 (08-24-04) CNA CORNER NOT ACCESSIBLE Z DENOTES DELTA ANGLE L DENOTES ARC LENGTH C.O. DENOTES CHORD BEARING PC DENOTES POINT OF CURVATURE PI DENOTES POINT OF INTERSEC71ON PRC DENOTES POINT OF REVERSE CURVATURE PT DENOTES POINT OF TANGENCY TYP TYPICAL A/C AIR CONDITIONER COW CONCRETE BLOCK WALL RP RADIUS POINT OHU OVERHEAD UTILITY LINE ID IDENTIFICAIION POL POINT ON LINE PLC POINT OF COMPOUND CURVE P.U.D. PLANNED URBAN DEVELOPMENT IUHPLATTEO PER THIS PLAT) 46.83„ 0 95 t 10926 SD LOT 96 o AI ki l I y12601 I 40.0' II TWO STORY b CONCRETE BLOCK 1 0+ & WOOD FRAME RESIDENCE FINISH FLOOR ELEVATION-16.36 COVEREDENTRY i o I 4' 1II II. WALK IS . ----- OFF ' - 1 10' A"279'31" - R- I ''•ivBOO.00' CB-N20'1 T21 "E 1 1 C-26.09' II1 PI I S70'57'5'E 11— 25.00 L— _ 1II i 1II i I1 I 1I NII 1I ID 1€ 1' I Ln J DO cr CO cil Ltl N J m I. 30' GRAPHIC SCALE O 15 30 LOT 94 f I•T+ 1 111iEW1AY; I IIJINTI WALK IS ALDFE— WILLOWBAY RIDGE L--225.91' 2- 5.81' S +p[` R-600.00' 1 BEET C8-MI0'45'13'E I // C-224.48' NOTE: WALNUT CREST RUN SO' RIONT-OF-WAY ALL DIRECTIONS AND DISTANCES HAVE 3£EN FIELD VERIFIED AND ANY 4CONSISTENCIES HAVE BEEN NOTED ON THE IURVEY, IF ANY. PROPERTY CORNERS SHOWN HEREON WERE ET/FOUND ON 08-24-04, UNLESS OTHERWISE HOWN. 3. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. I HAVE EXAMINED THE F I.R.M. COMMUNITY PANEL NO 120294 0035 E DATED 4/17 95 AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE IN ZONE X. AREA OUTSIDE 100 YEAR FLOOD PLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO THE A80VE INFORMATION. PLEASE CONTACT THE LOCAL F, E.M.A. AGENT FOR VERIFICATION. ELEVATIONS SHOWN HEREON ARE BASED ON SEMINOLE COUNTY VERTICAL CONTROL AS FURNISHED. BEARINGS SHOWN HEREON ARE BASED ON THE WESTERLY LINE OF LOT 95 BEING N00'01'41"W PER PLAT. FIELD DATE:) 04-06-04 REVISED: SCALE: I" s 30 FEET APPROVED BY: Si wAL a-24-04 CKB JOB NO. ASM39709 FORMBOARO 05-03-04 VH PLOT PLAN 02-04-04 500 DRAWN BY: LOi FIT 01-02-03 CKB 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 5. NOT VALIO WTHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIOA LICENSED SURVEYOR AND MAPPER. HINTER PARK, FLORIDA 32789 (407) 426- 7972 y19'04'16" L-199.71' R-600.00' PCCB-NO9'30'27'E C-190.79' _ — CENT£RL1NE RIGHT -OF -'MAY 0 6= 7'38'20" L= 76.66' R=575.00' CB=N15*13'25"E C=76.60' I HLREBY CERTIFY, THAT THIS BOUNDARY SURVEY, SUBJECT TO THE SURVEYOR'S NOTES CONTAINED HEREON MEETS THE APPLICABLE MINIMUM TECHNICAL STANDARDS" SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER SIG17-6, FLORIDA ADMINISTRATIVE CODE PURSUANT TO CHAPTER 4.72.027• FLORIDA STATUTES. g// FOR THE FIRM JAMES JAY ALES PSM #4997 DATI r,;,„ CENTEX POOLS & SPAS JOB No, Ad&-.ss. 1 ?? WALNUT CREST RUN C,t,,SANFORD L- 95 SL"I„ IEIO ,PRESERVE P LK M NROE _- 81_00 — 8•_p• i X 2 1 X 2 0 2 X 3 2 X 3 D 0 2 X 3 2 X 3 tD N ~ N ZD X X X N . NIA X 3 2 X z D 1 XZD1X2 in 1 X 2 I' II o co ap 1 X 2 2 X 3 2 X 3 0Nlrrxo,) January 01, 2006 LAWRENCE E. BENNETT, P.E. P.O. BOX 214368 SOUTH DAYTONA, FL 32121 386-767-4774 TO ALL BUILDING DEPARTMENTS Re: Master File Engineering. ALUMINUM STRUCTURES DESIGN MANUAL" 2004 edition & 2006 edition Dear Building Official/Plans Examiner, This is to certify that the following. contractor/company is hereby authorized to use my 2004 ed "ALUMINUM STRUCTURES DESIGN MANUAL" during the year 2006. When we publish and distribute the 2006 ed of the "ALUMINUM STRUCTURES DESIGN MANUAL", they will be authorized to use that manual for the remainder of 2006. Our authorization is based on a January to January basis requardless of the edition of the manual. This authorization also applies to contractor master file drawings, " ONE PERMIT ONLY" drawings or any site specific" drawings that I may furnish the contractor. David A. Johns Action Aluminum Products, Inc. 2698 South Orange Blossom Tr. Orlando, FL 32805 They are hereby added to my 2006 MASTERFILE LIST Should you,have',a questions please contact me at your convenience l)l 4 - SincerelV,' i, . 7 c- Lawrenc Bje in#16644 SECTION 1 SCREENED ENCLOSURES Table 1.1 Allowable Spans for Primary Screen Roof Frame Members Aluminum Alloy 6063 T-6 For Areas with Wind Loads up to 150 M.P.H. and Latitudes Below 30°-30'-00" North (Jacksonville, FL) Hollow Sections Tributary Load Width 'W' = Beam Spacing 3'.0" 1 4'-0" 1 5'-0" 1 6'-0" 1 7--0 1 8'.0" 1 9'-0" Allowable Span 'L' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 9'-10" b 8'-7" bi 7'-8" b 6'-11" DI b'-6" Di 6'-1" Dj 5'-8" b 2" x 2" x 0.055" 10'-9" b 9'-4" b 8'-4" b 7'-7" b 7'-1" b b'-7" b 6'-3" b 2" x 3" x 0.045. 13'4" b 11'-7" b 10'-4" b 9'-5" b 8'-9" b 8'-2" b 7'-8" b 2" x 4" x 0.050" 14'-8" b 12'-8" b 11'-4" b 1 10'-4" b 9'-7" b 1 8'-11" b I W-5" b Self Mating Sections Tributary Load Width 'W' = Beam Spacing 3'- 0" 1 4'-0" 1 5'-0" 1 6'-0" 1 7'-0" 1 8'4)" 1 9'-0" Allowable Span 'L' / bending 'b' or deflection 'd' 2" x 4" x 0.044 x 0.100" 19'-11" b 17'-4" b 15'-6" b 14'-2" b 13'-l" b 12'-3" b 1 V-6" b 2" x 5" x 0.050" x 0.100" 24'-9" b 21'-5" b 19'-2" b 17'-6" b 16'-2" b 15'-2" b 14'-3" b 2" x 6" x 0.050" x 0.120" 28'-7" b 24'-9" b 22'-2" b 20'-3" b 18'-9" b 17'-6" b 16'-6" b 2" x 7" x 0.055" x 0.120" 32'-3" b 27'-11" b 24--11" b 22'-9" b 21'-l" b 19'-9" b 18'-7" b 2" x 7" x 0.055" w/ insert 42'-10" b 37'-l" b 33'-2" b 30'-4" b 28'-l" b 26'-3" b 24'-9" b 2" x 8" x 0.072" x 0.224" 4V-7" b 36'-1" b 32'-3" b 29'-5" b 2T-3" b 25'-6" b 24'-0" b 2" x 9" x 0.072" x 0.224" 45'-l" b 39'-l" b 34'-11" b 31'-11" b 29'-6" b 27'-8" b 26'-l" b 2" x 9" x 0.082" x 0.310" 49'-6" b 42'-11" b 38'4" b 35'-0" b 32'-5" b 30'-4" b 28'-7" b 2" x 10" x 0,092" x 0.369" 59' 6" b 51'-7" b 46'-1" b 42'-l" b 38'-11" b 36'-5" b 34'4" b Snap Sections Tributary Load Width 'W' _ Beam Spacing 3'- 0" 1 4'-0" 1 5'-0" 1 6'.0" 1 7'-0"1 8'-0" Allowable Span'L' / bending'b' or deflection'd' 2" x 2" x 0.044" 11'-9" b 10'-2" b 9'-1" b 8'-4" b 7'-8" b 7'-2" b 6'-9" b 2" x 3" x 0.045" 15'-1" b 13'-l" b 11'-8" b 10'-B" b 9'-10" b 9'-3" b 8'-8" b 2" x 4" x 0.045. 18'-5" b 15'-11" b 14'-3" b 13'-0" b 12'-l" b 11'-3" b 10'-8" b 2" x 6" x 0.062. 31'-3" b 27'-l" b 24'-2" b 22'-l" b 20'-5" b 19'-2" b 88'-0" b 2" x 7" x 0.062" 34'-9" b 30'-l" b 26'-11" b 24'-7" b 22'-9" b 21'-3" b 20'-1" b Note: 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thickness shall be less than 0.040". 2. The structures designed using this section shall be limited to a maximum combined span and upright height of 55' and a maximum upright height of 20'. Structures larger than these limits shall have site specific engineering. 3. Spans are based on a minimum of 10# / Sq. Ft. for up to a 150 M.P.H. wind load: 4. Span is measured from center of beam and upright connection to fascia or wall connection. 5. Above spans do not include length of knee brace. Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 6. Purlin spacing shall not exceed 6'- 8" . For beam spans greater than 40'-0" the beam at the center purlin and one purlin for each 14'-0" on each side of the center purlin shall include lateral bracing as shown in detail (48'-0") span with purlins at 6'- 8" o.c. center purlin and (2) purlins each side of center purlin need lateral bracing. 7. Spans may be interpolated. Example: Max. 'L' for 2" x 4" x 0.050" hollow section with 'W' = 5'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368. SOUTH DAYTONA, FL 32121 TELEPHONE. ( 356) 767-4774 FAX: ( 386) 757-GW I PAGE A _ 56 I Q NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. I SECTION 1 BEAM -SCREEN ROOF J QW j W Q aQ O - zC=' 1 w e e ENC K E HOST STRUCTURE ROOFING 2) 2" LAG SCREWS (SEE SECTION 9 FOR SCREW SIZES) 2" STRAP LOCATE AND FASTEN PER STRAP LOCATION DETAIL PAGE 1-21 2" x 2" x 0.062" ANGLE EACH SIDE ( 3) EACH #8 S.M.S. EACH LEG INTO POST - BEAM CAP (SEE,PAGE 1-22) OPTIONAL 3/8" LAG SCREW AND 3/4" FERRULE FASCIA AND SUB -FASCIA SCREENED ENCLOSURES 0. 05" H-CHANNEL OR GUSSETS COMPOSITE 2 x 3 EAVE RAIL POST TO BEAM FASTENING SEE TABLE 1.6) e e SCREEN CD e MAY FACE.IN OR OUT) 90 e 6 REQUIRED KNEE BRACE MINIMUM SIZE AND CONNECTION ( SEE TABLE 1.7) ATTACHED NO MORE THAN 6" F- ui ABOVE TOP OF GUTTER n Co 0a< W W e e e e e e SOFFIT e SUPER OR EXTRUDED GUTTER IMAX. DISTANCE TO HOST STRUCTURE WALL 24" WITHOUT SITE SPECIFIC ENGINEERING IF KNEE BRACE LENGTH EXCEEDS TABLE 1.7 USE CANTILEVERED BEAM CONNECTION DETAILS SUPER OR EXTRUDED GUTTER RISER ( OR TRANSOM) WALL AT FASCIA - DETAIL 6 SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: ( 366) 767.4774 FAX: ( 386) 767-G&W- PAGE COPYRIGHT 20" 1 - 30 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SCREENED ENCLOSURES SECTION 1 Table 1.2 Allowable Spans for Secondary Screen Roof FrameWembers Aluminum Alloy 6063 T-6 For Areas with Wind Loads up to 150 M.P.N. and Latitudes Below 30'-30'-00" North (Jacksonville, FL) 4_ Sections Fastened Tn Rpams With Clins Hollow Sections Tributary Load Width 'W' = Purlin Spacing 3'-6" 1 4'-0" 1 4'-6" 1 5'-0" 5'-6" 1 6'-0" 1 6'-8" Allowable Span'L' / bending'b' or deflection'd' 2" x 2" x 0.044" T-8" d 7'4" d T-0" d 6'-9" d 6' 6" b 1 '-3" b 1 5'-11" b 2" x 2" x 0.055" 8'-1" d 7%9" d T-5" d 7'-2" d 6'-11" dl 6'-9" dl 6' 5" b 3" x 2" x 0.045" 8'-8" d 8'-3" d T-11" d 7'-S" d 7'-5" d 1 7'-3" d 1 6'-11" d 2" x 3" x 0.045" 10'-9" d 10'-3" d 9'4" b 9'-3" b 8' 10" bT S'-5" bj b 2" x 4" x 0.050" 12'-2" b 1 1'-4" b 10' 8" b 10' 21" b 9' 8" b 1 9'-3" b 1 8'4" b Snap Sections Tributary Load Width NY = Purlin Spacing 3'.6" 1 4'-0" 1 4'-5" 1 5'-0" 5'.6" 1 6'.0" 1 6'-S" Allowable Span 'L' / bending 'b' or deflection 'd' 2" x 2" x 0.044 8'-5" d 8'-1" d T-9" d T-6" d T-3" d 1 T-0" d 6'4" d 2" x 3" x 0.045" 11'-7" d 11'-1" d 10'-8" d 10' ' dj 9'-11" b 9'-6" b 9'-0" b 2" x 4" x 0.045" 14'-S" d 14'-0" d 1 13'-6" d 12'.9" bj 12'-2" bj 1 1'-S" b 11'-1" b B. Sections Fastened Through Beam Webs Into Screw Bosses Hollow Sections Tributary Load Width NY = Purlin Spacing 3'-6" 1 4'-0" 1 4'-5" 1 5'-0" r 5'-5" 6'-0" 1 6'-8" Allowable Span 'L' / bendirg'b' or deflection'd' 2" x 2" x 0.044" 9'-2" b 8'-7" b 1 8'-1" b T-8" b 7'-1" b 6' i 1" b 6'-7" b 2" x 2" x 0.055" 9'-11" b 9'4" b 8'-10" b 8'-4" b 7'-11" b 7'-7" b 7'-3" b 2" x 3" x 0.050" 12'-4" b 11'-7" b 10'-11" b 10'-"' b 9'-10" b 9' 5" b 8' 11" b 2" x 4" x 0.050" 13'-7" b 12'-8" b 11'-11" b 11'-4" b 10'-1G" b 10'-4" b 9'-10" b Snap Sections Tributary Load Width tiY' = Purlin Spacing 3'-6" 1 4'-0" 1 4'-6" 1 5'-0" 5'-6" 1 6'-0" 1 6--8" Allowable Span 'L' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 10'-11" bj 10'-2" bi 9'-7" b 1 9'-1" b 1 8'-8" b 1 8'-4" bj 7'-11" b Notes: 1. Thicknesses shown are "nominal" industry standard tolerances. No wa!I thickness shall be less than 0.040". 2. Spans are based on a minimum of 104 / Sq. Ft. for up ;o a 150 NI.P.H. vrind IoaC.3. Span is measured from center of beam and upright connection to fascia or v.atl connection. 3. Span is measured from center of beam and upright connection to fascia or wall connection. 4. Purlin spacing shall not exceed 6'-8". For beam spars a. eater than 40'-0" the beam at the center purlin and one purlin for each 14'-0" on each side of the center pur!in shall include lateral bracing as shown in detail 18'-0") span with. purlins at 6'- 8" O.C. Center purlln and (2) purlins each side of c_n:er purlin need latera! bracing. 5. Spans may be interpolated. CHECK TABLE 1.6 FOR MINIMUM UPRIGHT SIZE FOR BEAMS. Example: Max. 'L' for 2" x 4" x 0.050" hollow section fastened to beam with clips with 'W' = 5'-0" = 10'-2" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214358. SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767.4T74 FAX: (386) 767-6556 PAGE COPYRIGHT 2004 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERIJISSION OF LAWRENCE E. BENNETT, P.E 1 -57 SECTION 1 SCREENED ENCLOSURES SCREEN d' VARIES 4" SHO'V 1" x 2" O.B. BASE PLATE (TYP.) II SECONDARY 2" x (d - 2 ") x 0.063" ANGLE e EACH SIDE OF COLUMN W/ #10 S.M.S. SEE SCHEDULE NEXT PAGE) CONCRETE ANCHOR a, e m I a SEE SCHEDULE NEXT PAGE) NOTE: DETAIL ILLUSTRATES TYPICAL 2" x 4" S.M.B. COLUMN CONNECTION 2" 5d MIN.) (MIN.) SIDE VIEW SCREEN CONCRETE ANCHOR THRU ANGLE OR WITHIN 6" OF UPRIGHT IF INTERNAL SCREWS INTO SCREW BOSSES ,rr a v G v : e av e °.. • I IC 2" x 2" x 0.063" PRIMARY ANGLEI EACH SIDE 10 x 3/4" S.M.S. EACH SIDE SEE SCHEDULE NEXT PAGE) 5d• MINIMUM EDGE DISTANCE FROM EXTERIOR OF COLUMN TO OUTSIDE EDGE OF SLAB BOLT 0 • 5d DISTANCE va•' 1.1,,.. 3'2" 1-7,'B" I - GRADE 1-1/4" P:11N. CONCRETE ANCHOR EMBEDMENT TYPICAL S.M. OR SNAP SECTION COLUMN 2) #10 x 3/4" S.M.S. EACH SIDE PRIMARY 2" x 2" x 0.063" ANGLE 1" x 2" BASE PLATE (TYP.) I i L 1-1/4" MIN. CONCRETENOTE: SELECT CONCRETE ANCHOR ENIBEDIMENTANCHORFROMTABLE9.1 L6,. (MAX) _L 6" (MAX.) 3000 P.S.I. CONCRETE MAX. SPACING 24" O.C. FOR BOTH SIDES FRONT VIEW 2" x 4" OR LARGER SELF MATING OR SNAP SECTION POST TO DECK DFTAlt_s SCALE: 3" = 1'-0" NOTE: FOR SIDE WALLS OF 2" x 4" OR SMALLER ONLY ONE ANGLE IS REQUIRED, Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER. DEVELOPMENT CONSULTANT P.O. BOX 214368. SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4774 FAX: (386) 767-6556 PAGE COPYRIGHT 2004 1-50 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF L WMENCE E. BENNETT. P.E. SECTION 1 SCREENED ENCLOSURES Table 1.3 Allowable Post I Upright Heights for Primary Screen Wall Frame Members Aluminum Alloy 6063 T-6 For 3 second wind gust at velocity of 120 MPH or an applied load of 14 # / sq. ft.* Hollow Sections Tributary Load Width 'W' = Upright Spacing 3'.0" 4'-0" 5'.0" 1 6'-0" 1 7'.0" 1 8'.0" 9'-0" Allowable Height'H' I bending'b' or deflection'd' 2" x 2" x 0.044" 8'-4" b 7'-3" b 6'-6" b 5'-11" b 5'-6" b 5'.1" b 4'-10" b 2" x 2" x 0.055" 9'-1" b 7'-11" bj 7'-1" b 6'-5" b 5'-11" b 5'-7" b 5'-3" b 2" x 3" x 0.045' 11'-3" b 9'-9" b 8'-9" b 7'-11" b 7'-5" b 6'-11" b 6'-6" b 2" x 4" x 0.050" 12'-5" b 10%9" b 9'-7" b 8'-9" b 8'-1" b 7'-7" b 7'-2" b Self Mating Sections Tributary Load Width 'W' = Upright Spacing 3'. 0" 1 4'-0" 1 5'-0" 1 6'-0" 7'-0" 6'-0" 9'-0" Allowable Height'H' / bending 'b' or deflection'd' 2" x 4" x 0.044 x 0.100" 16'-11" b 14'-B" b 13'-1" b 11'-11" b 1 V-1" b 10'-4" b 9'-9" b 2" x 5" x 0.050" x 0.100" 20'-11" b 18'-l" b 16'-2" b 14'-9" b 13'-8" b 12'-10" b 12'-l" b 2" x 6" x 0.050" x 0.120" 24'-2" b 20'-11" b 18'-9" b 17'-l" b 15'-10" b 14'-10" b 13'-11" b 2" x 7" x 0.055" x 0,120" 27'-3" b 23'-7" b 21'-1" b 19'-3" b I T-10" b 16-8" b 15'-9" b 2" x 7" x 0.055" w/ insert 36'-3" b 31'-4" b 28'-l" b 25'-7" b 23'-9" b 22'-2" b 20'-11" b 2" x 8" x 0.072" x 0.224" 35'-2" b 30'-6" b 27'-3" b 1 24'-10" b 23'-0" b 21'-6" b 20'-4" b 2" x 9" x 0.072" x 0.224" 38'-2" b 33'-0" b 29'-6" b 26'-11" b 24'-11" b 23'4" b 22'-0" b 2" x 9" x 0.082" x 0.310" 41'-10" b 36'-3" b 32'-5" b 29'-7" b 27'-5" b 25'-8" b 2" x 10" x 0.092" x 0.369" 50'-4" b 43'-7" b 38'-11" b 35'-7" Snap Sections Tributary Load Width 'W'= Upright Spacing 3'- 0" 1 4'.0" 1 5'-0" 1 6'-0" 1 7'.0" 1 8'-0" 1 9%0" Allowable Height 'H' I bending 'b' or deflection'd' 2" x 2" x 0.044" 9'-11" b 8'-7" b 7'-8" b 7'-0" b 6'-6" b 6'-l" b 5'-9" b 2" x 3" x 0.045" 12'-9" b 11'-0" b 9'-10" b 9'-0" b 8'-4" b 7'-10" b 7'-4" b 2" x 4" x 0.045' 15'-7" b 13'-6" b 12'-1" b 11'4" b 10'-2" b 9'-7" b 8'-11" b 2" x 6" x 0.062" 26'-5" b 22'-10" b 20'-5" b 18'-8" b 17'-3" b 16'-2" b 15'-3" b 2" x 7" x 0.062" 29'-5" b 25'-5" b 22'-9" b 20'-9" b 1 19'-3" b 17'-11" b 10 -11" b For allowable heights at wind velocities other than 120 MPH, see conversion table 1A on the specification page for tables at the beginning of this section and example below. Note: 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thic'r,ness shall be less than 0.0:0". 2. Using screen panel width 'W' select upright length 'H'. 3. Above heights do not include length of knee brace. Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 4. Site specific engineering required for pool enclosures over 20' in mean roof height. 5. Height is to be measured from center of beam and upright connection to fascia or wall connection. 6. Chair rails of 2" x 2" x 0.044" min. and set @ 36" in height can be considered as residential guardrails provided they are attached with min. (3) #10 x 1-1/2" S.M.S. into the screw bosses and do not exceed 8'-0" in span. 7. Heights may be interpolated. CHECK TABLE 1.6 FOR MINIMUM UPRIGHT SIZE FOR BEAMS. IF SPANS FOR 'C' EXPOSURE CATAGORY AND/OR WINDZONES OTHER THAN 120 MPH ARE REQUIRED, SEE EXAMPLE ON SPECIFICATION PAGE FOR TABLES AT THE BEGINNING OF THIS SECTION. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: ( 386) 767-4774 FAX. ( 386)767-65M IPAGE 1 -58 I O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LA'NRENCE E. BENNETT, P.E. I SCREENED ENCLOSURES SCREWS OR THRU-BOLTS SEE SECTION 9) 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS WITHIN 6" OF EACH SIDE OF EACH POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL SECTION 1 POST SIZE 2" x 4" MAX. MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 - 10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE POST TO PLATE TO CONCRETE DETAIL SCALE: 3" = 1'-0" 2" x 2" .x 0.063" ANGLE EACH SIDE ATTACH TO POST AND CONCRETE @ LOAD BEARING WALL W/ (2) MIN. S.M.S. (PER SECTION 9) EACH SIDE MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 - 10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE ANGLES AS SHOWN ABOVE MAY BE USED TO CONNECT CHAIR RAILS AND PURLINS POST SIZE 2" x 4" MAX. SEE TABLE) 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS 6" MAX. EACH SIDE OF EACH POST AND @ 24" O.C. MAX. OR THROUGH ANGLE AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL ALTERNATE POST TO BEAM AND PLATE TO CONCRETE DETAIL SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER . DEVELOPMENT CONSULTANT P.O. BOX 214368. SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767.4774 FAX: (386).767.-6556 O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1 PAGE 1 -47 I SCREENED ENCLOSURES SECTION 1 Table 1.4 Allowable Post 1 Girt I Chair Rail Spans, Header Spans & Upright Heights for Secondary Screen Wall Frame Members Aluminum Alloy 6063 T-6 For 3 second wind gust at velocity of 120 MPH or an applied load of 14 # / sq. ft.* I_ ro-t. Witk PH Hollow Sections 2" x 2" x 0.044" 2" x 2" x 0.055" Tributary Load Width'W' 3'- 6' 4'.0" 1 4'.6" 1 5'-0" 1 5'-6" 1 6'-0" 6'-8" Allowable Heights 'H' / bending 'b' or deflection 'd' 6'- 10" d 5'-5" b 6'-1" b 5'-9" b 5'-6" b 5'-3" b 1 5'-0" T- 3" d 6'-11" d 6'-6" b 6' ." b 6'.0" b ;'-9" b 5'-6" b b 3" x 2" x 0.045" 7'-9" d 7'-5" d 7'-V d 6'-10" d 6'-7" b 6'-4" b 1 5'-11" b 2" x 3" x 0.045" o'=" o 8'-9" b 8'-3" b 7'-10" b 7'-5" b 7' 2" b 1 6'-9" b 2" x 4" x 0.050" 10'-3" b 9'-7" b 9'.0" b 8'-7" b 5'-2" b 7'-,0" b 1 T-5" b Snap Sections Allowable Heights 'H' / bending 'b' or deflection 'd' , 2" x 2" x 0.044" 7'-5" c 7'-2" d 6'-11" d 6'-K b 6'-1" b 1 ,' b 1 5'-9" b l r__.___ J T- D- - TL.. .. F. Cir,.n Intn CZ-- Rneeoe Hollow Sections Tributary Load Width NY 3'- 6' 1 4'-0" 1 4'.6" 1 5'.0" 1 5'.6" 1 6'-0" 1 6'.8" Allowable Heights 'H' / bending'b' or defiection'd' 2" x 2" x 0.044" 7'.9" b 7'-3" b 5'.10" b 6'-6" b 1 6'-2" b 1 5'-11" b 5'-7" b 2" x 2" x 0.055" 8'-5" b 7'-11" b 7'-5" b 7'-l" b 6'-9" b 1 6'-5" b 6'-1" b 3" x 2" x 0.045" 9'-3" b 8'-8" b 8'-2" b 7'.9" b 7'-5" b 1 7'-l" b 5'-8" b 2" x 3" x 0.045" 10'-5" b 9'-9" b 9'.2" b 8'.9" b 8'-4" b 7'-11" b 7'-7" b 2" x 4" x 0.050" 11'-6" b 10'-9" b 10'-1" b 9'-7" b 9'-2" b 8'-9" b 8'4" b Snap Sections Allowable Heights 'H' / bending 'b' or deflection'd' 2" x 2" x 0.044" 9'-2" b 1 8'-7" b 1 8'-l" b 1 7'-8" b 1 7'-4" b 1 7'-0" b 1 6'-8" b For a[Iowa Die nelgnrs a1wino velocmes o,ner ma„ ,cv mrn, *CC - .a,..... -....- specifications for tables page at the beginning of this section and example below. Notes: 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thickness shall be less than 0.0=0". 2. Using screen panel width 'W' select girt lengths. 3. Site specific engineering required for pool enclosures over 20' in mean roof height. 4. Span is to be measured from center of beam and upright connection to fascia or wall connection. 5. Chair rails of 2" x 2" x 0.044" min. and set @ 36" in height can be considered as residential guardrails provided they are attached with min. (3) #10 x 1-1/2" S.M.S. into the screw bosses and do not exceed 8'-0" in span. 6. Girt spacing shall not exceed 6'-8". 7. Spans may be interpolated. IF HEIGHTS FOR 'C' EXPOSURE CATAGORY AND/OR WINDZONES OTHER THAN 120 MPH ARE REQUIRED, SEE EXAMPLE ON SPECIFICATION PAGE FOR TABLES AT THE BEGINNING OF THIS SECTION. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: ( 386) 767AT74 FAX: ( 386) 767-6556 I PAGE I COPYRIGHT2004NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERAIISSION OF LAWRENCE E. BENNETT, P.E. 1 59 e SECTION 1 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS 6" MAX. EACH SIDE OF EACH POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 MIN, 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE SCREENED ENCLOSURES. POST SIZE 2" x 4" MAX. SIDE WALL POST TO PLATE TO CONCRETE DETAIL SCALE: 3" = 1'-0" 1" x 2" EXTRUSION ANCHOR TO CONC. W/ CONC. ANCH. 6" MAX. EA. SIDE OF EA. POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 MIN. 3-1/2" SLAB 2500 P.S.I. CONC. 6 x 6 - 10 x 10 W.W.M. OR FIBER MESH CONC. 2" x 2", 2" x 3" OR 2" x 4" HOLLOW SECTION SEE TABLES) MIN. (3) #10 x 1-1/2" S.M.S. INTO SCREW BOSSES MASONRY ANCHOR @ 6" EA, SIDE OF POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SIDE WALL HOLLOW POST TO BASE DETAIL SCALE: 3" = 1'-0" POOL ENCLOSURE UPRIGHT TO DECK ANCHOR REQUIREMENTS General Notes and Specifications: 1. The uplift load on a pool enclosure upright is calculated as 1/2 the beam span x the beam spacing x the screen load of 7# / Sq. Ft. EXAMPLE: FOR A 2" x 6" BEAM WITH A SPAN OF 23' AND A BEAM & UPRIGHT SPACING OF 7' USE: r 1/2 x 17'-11" x Tx 109 / Sq. Ft. = 627.2# UPLIFT 2. Table 1.6 of this manual uses the worst case loads for all cases. 3. In all cases there must be a primary anchor within 6" of each side of the upright. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767.4774 FAX: (386) 7674M PAGE COPYRIGHT 2004 1 -48 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SCREENED ENCLOSURES I SECTION 1 Table 1.6 Minimum Upright Sizes and Number of Screws for Connection of Roof Beams to Wall Uprights or Beam Splicing Beam Size Upright Size Minimum Purlin, Girt Knee Brace Size" Deck Anchors Notes Minimum Number of Screws' Beam Stitching Screw @ 24" O.C. 8 x'/," 10 x I", 12 x'/," 2" x 3" 2" x 3" 2" x 2" x 0.044" 2 Full Lap 6 4 4 2" x 4" 2" x 3" 2" x 2" x 0.044" 2 Full Lap 8 6 4 8 2" x 4" 2" x 4" 2" x 2" x 0.044" 2 Full Lao 8 6 4 10 2" x 5" 2" x 3" 2" x 2" x 0.044" 2 Full Lap 8 6 4 8 2" x 6" 2" x 3" 2" x 2" x 0.044" 4 Fuli Lap 0 r3 1 6 10 2" x 6" 2" x 4" 2" x 2" x 0.044" 4 Pariai Lac 10 8 6 10 2" x 7" 2" x 4" 2" x 2" x 0.044" 4 Par.,ial Lap, 14 12 10 12 2" x 8" 2" x 5" 2" x 3" x 0.044" 6 Partial Lap 16 14 12 14 2" x 9" 2" x 6" 2" x 3" x 0.045" 6 1 Lap i8 1i5 14 14 2" x 9" 2" x 7" 2" x 4" x 0.050" el Parlal Lap 20 18 16 14 2" x 10" 2" x 8" x 4" Y. 0.01U" I lr ial Lag 20 i$ 16 14 Screw Size Minimum Distance and Spacing of Screws V Gusset Plate Thickness Edge To Center Center To Center Beam Size Thickness 18 5116" 5!3" 2" x 7' x 0.055" x 0.120" 1/16" = 0.063" 10 3!8" 3/4" 2" x 8" x 0.072" x 0.224" 1/8" = 0.125" 412 1/2" 1" 2" x 9" x 0.072" x 0.224" 1/8" = 0.125" 5/16" 7/8" 2" x 10•' x 0.092" x 0.369" 1/4" = 0.25" 3,8„ 2 Refers to each side of the connection of the beam and upright and each side of splice connection. 0.082" wall thickness, 0.310" flange thickness Note: 1. Connection of 2" x 6" to 2" x 3" shall use a full lap cut or ill 6" gusset plate. 2. All gusset plates shall be a minimum of 5052 H-32 Alloy or have a minimum yield strength of 23 ksi. 3. For beam splice connections the number of screws shown is the total for each splice with 1/2 the screws on each side of the cut. 4. The number of screws is based on the maximum allowable moment of the beam. 5. The number of deck anchors is based on RAVVL R Tapper allowable load data for 2,500 psi concrete and / or equal anchors may be used. The number shown is the total use 1/2 per side. 6. Hollow splice connections can be made provided the connection is approved by the engineer. 7. If a larger than minimum upright is used the number of screws is the same for each splice with 112 the screws on each side of the cut. 8. All beam to upright connections for 2" x 7" beams or larger shall have an internal or external gusset plates. Gusset plates are required for mansard or gable splice connections. 9. For gusset plate connections 2" x 9" beams or larger use 3/4" long screws. 10. The side wall upright shall have a minimum beam size as sho .n above, ie., a 2" x 4" upright shall have a 2" x 3" beam. 11. Connect beam to upright w/ H-bar, gusset plate, or angle clips for each splice with 1/2 the screws on each side of the cut. 12. For girt size use upright size (i.e. 2" x 6"). Read the 2" x 6" beam row for min. girt of 2" x 2" x 0.044". Table 1.7 Minimum Size Screen Enclosure Knee Braces and Anchoring Required Aluminum 6063 T-6 Brace Length Extrusion Anchoring System 0' - 2'-0" 2" x 2" x 0.044" 2" H-Channel With 3 #10 x 1/2" EACH SIDE To 3'-0" 2" x 3" x 0.045" 2" H-Channel With 3 #10 x 1/2" EACH SIDE To 4'-0" 2" x 4" x 0.044" x 0.12" 2" H-Channel With (4) 3/4" long screws size to be determined by beam size, see table 9.6) See Table 1.6 For Number And Size Of Screws) Note: 1. For required knee braces greater than 4'-6" contact engineer for specifications and details. 2. Cantilever beam detail shown on page 1-32 shall be used for host structure attachment when knee brace length exceeds 4'-6". Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4 74 FAX: (386) 767-6556 I O NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1 PAGE 1 -61 I SECTION 1 I SCREENED ENCLOSURES MINIMUM POST SIZES REQUIRED FOR EACH BEAM SIZE (SEE TABLE 1.6) 2"x4"OR2"x6" SELF MATING BEAM 1".x 2" SNAP SECTIONS 2 ATTACHED TO 2" x 2" W/ 10 x 1-1/2" S.M.S. @ 24" O.C. I OR CONTINUOUS SNAP i / SECTIONS OR 2" x 3" (4) SPLINE GROOVE SECTION g PM 6„ 2„ i._ X 1 x 2" OPEN BACK FASTENED I TO POST W/ (2) #10 x 1-1/2" ALTERNATE FLAT ROOF S.M.S. I SELECT FASTENER SIZE, ATTACH 2" x 2" PURLINS TO NUMBER AND PATTERN SELF MATING BEAMS W/ (2) SEE TABLE 1.6 & 9.5A OR 9.56) 10 x 1.112" S.M.S. INTO SCREW BOSSES o 2" x 3" HOLLOW OR SNAP . SECTION SLOPING BEAM TO UPRIGHT CONNECTION DETAIL PARTIAL LAP SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214368. SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4774 FAX: (386)767.6M PAGE @ COPYRIGHT 204 1-8 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. SCREENED ENCLOSURES I SECTION 1 W PURLINS (TYP.) SCREEN (TYP.) CABLE CONNECTION SEE DETAILS SECTION 1) ALTERNATE CABLE H SEE TABLE 1.3) 1" x 2" (TYP.) I- GRADE K-BRACING (OPTIONAL) _ CABLE CONNECTION GIRT (TYP.) (SEE DETAILS SECTION 1) TYPICAL DOME ROOF - ELEVATION EXISTING STRUCTURE ALUMINUM BEAM TABLE 1.1 OR 1.8) L SIZE MEMBERS PER APPROPRIATE TABLES r H SCALE: N.T.S. RISER WALL WHERE W REQUIRED' PURLINS (TYP.) DIAGONAL ROOF BRACING SEE SCHEMATIC SECTION 1) CABLE BRACING . K-BRACING (OPTIONAL) - GIRT (TYP.) SCREEN (TYP.) SW ALUMINUM COLUMNS (TYP.) TABLE 1.3 OR 1.6) PERIMETER WALLS FRAMING 1" x 2" (TYP.) (SEE TABLES 1.3 AND 1.4.) TYPICAL DOME ROOF - ISOMETRIC SCALE: N.T.S. CONNECTION DETAILS AND NOTES ARE FOUND IN THE SUBSEQUENT PAGES. Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (388) 757.4774 FAX: (386) 767-65% PAGE CQ COPYRIGHT 2004 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 1-3 SCREENED ENCLOSURES PURLIN (^ SCREEN C SEE T SECTION 1 CABLE CONNECTION SEE DETAILS SECTION 1) GIRT (TYP.) 1" x 2" (TYP.) GRADE CABLE CONNECTION SEE DETAILS SECTION 1) TYPICAL TRANSVERSE GABLE ROOF - ELEVATION SCALE: N.T.S. EXISTING STRUCTURE SIZE MEMBERS PER APPROPRIATE TABLES K-BRACING (OPTIONAL) ALUMINUM COLUMNS (TYP.) TABLE 1.3 OR 1.6) SCREEN (TYP.) PERIMETER WALLS FRAMING TABLE 1.3 OR 1.4) TYPICAL L- L RISER WALL WHERE REQUIRED PURLIN (TYP.) 6. ALUMINUM BEAM TABLE 1.1 OR 1.8) DIAGONAL ROOF BRACING SEE SCHEMATIC SECTION 1) 7t GIRT (TYP.) 1" x 2" (TYP.) CABLE BRACING E GABLE ROOF - ISOMETRIC SCALE: N.T.S. CONNECTION DETAILS AND NOTES ARE FOUND IN THE SUBSEQUENT PAGES Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 767.4774 FAX: (386) 767.as" COPYRIGHT 2W NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. PAGE 1-5 SCREENED ENCLOSURES SECTION 1 5) #10 S.M.S. (MIN.) - 1/8" x 1-1/2" x 8" FLAT BAR 0.125" PLATE OUT ON 45° ANGLE EYE -BOLT OR TURNBUCKLE FOR CABLE TENSION STAINLESS STEEL (SEE TABLE) PERIMETER FRAMING MEMBER TYPICAL CABLE CONNECTIONS AT CORNER - DETAIL 1 EITHER A OR B 1" x 2" x 0.125" CLIP AND (4) 10 x 3/4" S.M.S. EACH SIDE FOR CABLES SCALE: 3" = 1'-0" A V-900-M-Plep ALTERNATE: USE (1)1/4" x 1-1/4" FENDER WASHER EACH SIDE OF FRAME MEMBER MIN. (2) CLAMPS REQUIRED TYP.) MIN. 1/4" EYE BOLT. WELD EYE CLOSED (TYP.) ALTERNATE TOP CORNER OFCABLE CONNECTION - DETAIL 1A SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE: (386) 767-4774 FAX 8) COPYRIGHT 2004 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1-41 SECTION 1 I SCREENED ENCLOSURES MIN.3-3/4" 4" NOMINAL) SLAB MIN. (2)1/4" OR 5/16" x 1-3/4" MIN. 5d CONCRETE ANCHORS 6d ALTERNATE CLIP: MIN. 5 .I 3" ASTM A-36 PRESSED STEEL CLIP TYPICAL CABLE CONNECTION AT SLAB DETAIL - DETAIL 2 SCALE: 3" = V-0" ANCHOR PER TABLE 9-1A MIN. SHEAR 607# FOR 3/32" CABLE ` AND 902# FOR 1/8" CABLE SLAB FOR 1/8" CABLE SHALLFOR3/32" CABLE 5/16" x 2" O HAVE A THICKENED EDGE TOCONCRETEANCHORW/ ACHIEVE 5d MIN. AND A 3/8" xCABLETHIMBLEANDWASHER2" ANCHOR tIa 3-1/2" (4" NOMINAL) SLAB (MIN.) 5d (MIN.) 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE ALTERNATE CABLE CONNECTIONS AT FOUNDATION - DETAIL 2A SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CM. ENGINEER -DEVELOPMENTCONSULTANT P.O. BOX 214366, SOUTH DAYTON& FL 32121 TELEPHONE: (386) ?W-4774 FAX: (386) 767-65M PAGE COPYRIGHT 2004 1-42 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. SECTION 1 I SCREENED ENCLOSURES • LAB MIN. (2)1/4' OR 5/16" x 1-3/4" CONCRETE ANCHORS ALTERNATE CLIP: 3" ASTM A-36 PRESSED STEEL CLIP TYPICAL CABLE CONNECTION AT SLAB DETAIL - DETAIL 2 SCALE: 3" = V-0" ANCHOR PER TABLE 9-1A MIN. SHEAR 607# FOR 3132" CABLE AND 902# FOR 1/8" CABLE SLAB FOR 118" CABLE SHALL FOR 3/32" CABLE 5/16" x 2" p HAVE A THICKENED EDGE TOCONCRETEANCHORW/ /Z ACHIEVE 5d MIN. AND A 3/8" xCABLETHIMBLEANDWASHER2" ANCHOR A, 5d (MIN.) 3-'1/2" (4" NOMINAL) c SLAB (MIN.) I 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR FIBER MESH CONCRETE ALTERNATE CABLE CONNECTIONS AT FOUNDATION - DETAIL 2A SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CML ENGINEER- OEVELOPINENT CONSULTANT P.O. BOX 214388, SOUTH DAYTONA, FL 3212i TELEPHONE: (386) 7874T74 FAX: (388) 78r ms PAGE COPYRIGNT2884 1-42 NOT TO BE REPROOUCEO IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT, P.E. r SECTION 1 ADDITIONAL FASTENING, NUMBER OF FASTENERS PER TABLE 1.6 & 9.5 EXCEPT ALL SHADED LOCATIONS SHALL BE FILLED MINIMUM OF ALL OUTER LOCATIONS 10) #8 x 1/2" S.M.S. EACH SIDE OF BEAM / POST 1" x 2" OPEN BACK ATTACH TO 2" x 2" W/ #10 x 1-1/2" S.M.S. @ 24" O.C. OR CONTINUOUS 2" x 3" (4) SPLINE GROOVE SECTION CONNECT 2"x 2"OR 2"x 3"TO BEAM W/ MIN. OF (3) 10 x 1-1/2" S.M.S. INTO SCREW BOSSES SCREENED ENCLOSURES EXISTING 2" x 6" SELF. MATING BEAM 10 x 31/2" S.M.S. 16" O.C. PROPOSED 2" x 3" x 0.050" SMOOTH SIDE DOWN 1/8" x 2-3/4" x 8" GUSSET EACH SIDE OF POST AND BEAM W/ 6) #8 x 1/2" S.M.S. EXISTING 2" x 4" ADDITION OF 2" x 3" TO EXISTING 2" x 6" S.M.B. SCALE: 3" =1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPJNENT CONSULTANT P.O. BOX 214368. SOUTH DAYTONA. FL 32121 TELEPHONE. (NO)T8T-4TT4 FAX:, (380) TOT -ON -- - PAGE - COPYRIGHT 2004 1-14 NOT TO BE REPRODUCEO IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. SCREENED ENCLOSURES CONNECTOR MAY BE (2) ANGLES, INTERNAL'U' CHANNEL OR EXTERNALLU' CHANNEL EACH SIDE OF CONNECTING BEAM W/ SCREWS (PER SECTION 9) CARRIER BEAM SEE TABLE 1.5) MINIMUM NUMBER S.M.S. 3/4" LONG REQUIRED EQUAL TO BEAM DEPTH SEE SECTION 9) r., u SECTION 1 EXTRUSIONS W/ INTERNAL SCREW BOSSES MAY BE CONNECTED W/ (3) #10 x 1-112" 1 INTERNALLY I PRIMARY BEAM SEE TABLE 1.1 OR 1.8) CARRIER BEAM TO BEAM CONNECTION DETAIL SCALE: 3" = V-0" ALTERNATE: 1"x2".1"x3"OR2"x2" ATTACHED TO WALL W/ #10 x 2" S.M.S. @ 16" O.C. HOST STRUCTURE MASONRY OR FRAMED WALL SELECT FASTENERS FROM N BEAM TO WALL CONNECTION: 2) 2" x 2" x 0.060" EXTERNALLY MOUNTED ANGLES ATTACHED TO WOOD FRAME WALL W/ MIN. (2) 3/8" x 2" LAG SCREWS PER SIDE OR TO CONCRETE W/ (2) 1/4" x 2-1/4" ANCHORS OR MASONRY WALL ADD (1) ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" SECTION 9 TABLES) w ALTERNATE CONNECTION: a 1) 1-3/4" x 1-3/4" x 1-3/4" x 1 /8" INTERNAL U-CHANNEL ATTACHED TO WOOD FRAME PRIMARY OR MISC. FRAMING WALL W/ MIN. (3) 3/8" x 2" LAG BEAM (SIZE PER TABLES) SCREWS OR TO CONCRETE ANGLE OR RECEIVING OR MASONRY WALL W/ (3) 1/4" x 2-1/4" ANCHORS OR ADD (1) CHANNEL ANCHOR PER SIDE F OR EACH INCH OF BEAM DEPTH LARGER THAN 3" BEAM TO WALL CONNECTION DETAIL SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER -DEVELOPMENT CONSULTANT P.O. BOX 214358, SOUTH DAYTONA, FL 32121 TELEPHONE: (386) 787-47T4 FAX: (386) 7574M COPYRIGHT 2004 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1-37 SCREENED ENCLOSURES 1/4" x 6" RAWL TAPPER THROUGH 1" x 2" AND ROWLOCK INTO FIRST COURSE OF BRICKS ALTERNATE CONNECTION OF SCREENED ENCLOSURE FOR BRICK OR OTHER NOW STRUCTURAL KNEE WALL 1" WIDE x 0.063" THICK STRAP @ EACH POST FROM POST TO a.. FOOTING W/ (2) #10 x 3/4" S.M.S: STRAP TO POST AND 1) 1/4" x 1-3/4" CONCRETE ANCHOR TO SLAB OR FOOTING SECTION 1 ALUMINUM FRAME SCREEN WALL CAP BRICK BRICK KNEEWALL TYPES' MORTAR REQUIRED FOR LOAD BEARING BRICK WALL 4" (NOMINAL) PATIO CONCRETE SLAB (SEE NOTES CONCERNING FIBER MESH) 3) #30 BARS OR (1) 50 BAR W/ 2-1/2" COVER TY P. ) BRICK KNEEWALL AND FOUNDATION FOR SCREEN WALLS SCALE: 314" = 1'-0" 2'-0" MIN 3-1/2" (TYP. 2 143 BAR CONT. OR 1 #5 BAR CONT. BEFORE SLOPE ALL SLABS) Q— TYPE FLAT SLOPE / NO FOOTING 0-2" / 12" 00 8" — TYPE II MODERATE SLOPE FOOTING 2" / 12" - V-10" 1 ) #5 BAR CONT. 3 #3 BAR CONT. OR TYPE III STEEP SLOPE FOOTING V-10" Notes for all foundation types: 1. No footing required except when addressing erosion until the slab width in the direction of the primary exceeds 32 ft., then a Type II footing is required under the load bearing wall only unless the side wall exceeds 16 ft. in height or the enclosure is in a "C" exposure catagory in which case a Type II footing is required for all walls. 2. The foundations shown are based on a minimum soil bearing pressure of 1,500 PSF. Bearing capacity of soil shall be verified, using a pocket penetrometer, field soil test, or by a soil testing lab, to be above 1,500 PSF prior to placing the slab. 3. The slab / foundation shall be cleared of debris and roots and compacted prior to placement of concrete. 4. Monolithic slabs and footings shall be minimum 2,500 psi concrete with 6 x 6 -10 x 10 welded wire mesh or crack control fiber mesh: Fibermesh ® Mesh, InForceT"' e3l (Formerly Fibermesh MD) per maufacturer's specification may be used in lieu of wire mesh. 5. If local building codes require a minimum footing, use Type II footing or footing sections required by local code. Local code governs. SLAB -FOOTING DETAILS SCALE: 314" = 1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA, FL 32121 TELEPHONE: (386)T87-4TT4 FAX: (386) T67-6556 COPYRIGHT 2004 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1 -55