HomeMy WebLinkAbout800 Santa Barbara StPermit # : n 1 Job Address: Description of Work: Historic District: Zoning: CITY' OF SAN?ORD PERMIT APPLICATION Date: I( O k" Value of Work: S Z 3 9%9 ` Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: 2A O Construction Type: _ # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: C 1 Z', 30 Sy04 210b V I Lo (Attach Proof of Ownership & Legal Description) Owners Name & Address: Tit-Mqs V LR(C1T 8CR> S a..rrw 6AAA AA. to A"2 L SAaE•wis Phone: 401 .314 67 L o Contractor Name & Address: A VV A -i C4k0 M 001 %4L N%-P ti SU Zrsrwd 3411 CftmwbA8A %A-4— Cr CA-til:da,stis, Oft f1 State License Number: CGG 0 3317.1 Phone & Fax: Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer: , IAN Q ZU04Phone: Address: Fax: z4e= Application is hereby made to obtain a permit to dti the work t I1 io as#OE c ify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to a - s of I n construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBIN RNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, then; may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is v tion that I wt noti e r f he property of the require ents of Florida Lien Law, FS 713. S 1-6—fly 7 - cot Signature of Owner/Agent Date Sig a re of Contractor/Agent Date 1— oAn cos Ey L A&i •4-L • -t Print Owner/Agent's Name n o ctor/Agent's Na Signature of Notary4ate of Florida Si re of Notary -State of Florida Date Michaeft`urryY ," . MYFLORENCE A DE GRAVE Commission #DD 166471 * MY COMMISSION I DO 164260 y - Expires: Nov 18, 2006 * PIRES:November12,2008 Owner/AgentisPersonaoMeorBondedThru1Crector8nl+psor Produced ID ''. 11WO Atlantic Bonding Co,. Inc. Produc h- 16d 11101a! APPLICATION APPROVED BY: Bldg ` 1 . 9 —OV Special Conditions: Zoning: Initial & Date) ( Initial & Date) Utilities: I. FD: e% k 0 Initial & Date) ( Initial & Date) ADVANCED MOBILEHOME SYST)EMS AMS'K INC. 345 Commercial St. Casselberry, FL 32707 1-6-04 Casselberry (407) 834-0416 State Wide Toll Free 1-800-329-5787 FAX 1-407-834-5308 Upon visual inspection & physical measurment I certify that the existing concrete slab is at least 411 thick. 4 JOB SITE: Thomas Everett 800 Santa Barbara Dr Lot 26 Sanford, F1 32773 DreamWold MHP 411T k QA,..-1 M chael Murray CGC033977 PLANS REVIEWED CITY OF SANFORD o'a'Y• ° FLORENCE A. DE GRAW MY COMMISSION # DD 1642E:- EXPIRES: November 12, 2*: Boyd TIn BVW NOWY Service: LICENSED & INSURED • CG C033977 CC C042787 SERVING: Lake, Marion, Orange, Osceola, Seminole, Sumter and Volusia Counties AMTS PLOT PLAN CUSTONERJOry, w 4,eaoT CON T. ADDRESS - &Ob SA.. -WA gMave , 00- 'PHONE # 3194 CITY STATE ZIP _3_&7ZZ LOT 4 A FT F T Itk- t4-1 r 4— 1-4 a__ T PROPOSED CONSTRUCTION: I I I I SQ. FT. ,Aqc? JOB COST 07 I AMS V ti j 345. Commercial St Casselberry, FL 32707: Ir I SECTION 7 SOLID ROOF PANEL PRODUCTS Table 7.1.3 Allowable Spans for Industry Standard Riser Panels for Various Loads Aluminum Alloy 3105 H-14 or H-25 3" x 12" x 0.024" 2 or 5 Rib Riser Panels _ Glass Rooms Wind Region Open Structures Mono -Sloped Roof tScreen Rooms Ira-. Attached Cov—ers Partially Enclosed Enclosed Overhang Cantilever All Roofs 1&2 span 1 3 span 4 span 1&2 span 3 span 4 span 1&2 span 3 span 4, span 1&2 span 3 span 4 span 100 MPH 14'-11" 18'-6" 18'-10" 14'-1" 17'-11" 18'-3' 10'-7" 13'-7" 13'-11" 11'-6" 14'-8" 14'-11" 4'-0' 110 MPH 14'-6" 18'-6" 18'-10" 13'-1" 16'-2" 16'-5" 9'-11" 12'-8" 12'-11" 10'-9" 13'-10" P12'-11" 4'-0' 120 MPH 13'-8" 1T-11" 18'-3" 12'-6" 15'-6" 15'-9" 9'-5" 11'-8" 11'-10" 10'-2" 12'-11" 3'-10" 123 MPH 13'-6" 17'-5" 17'-9" 12'-4" 15'-3" 15'-6' 9'-3" 11'-5" 11'-8" 9'-11" 12'-9" 3'-9" 130 MPH IT-1" 16'-2" 16'-5" 11'-6" 14'-8" 14'-11' 8'-11' 11'-0- 11'-3" 9'-8" 12'-3" 3'-8" 140 MPH 10'-4" 12'-10" 13'-1" 10'-4" 12'-10" 13'-1" 8'-6" 10'-6" 10'-9" 9'-2" 11'-4" 3'-6" 150 MPH 10'-4' 12'-10" 13'-1" 10'-4" 12'-10" 13'-1" 8'-2" 10'-l" 10'-3" 8'-9" 10'-10' 3.4" 3" x 12" x 0.030" 2 or 5 Rib Riser Panels I Glass Rooms Wind Region Open Structures Mon -Sloped Roof Screen Rooms Attached Covers Partially Enclosed Enclosed Overhang ! Cantilever All Roofs 1&2 span 3 span 4 span 1&2 span 3 span 4 span 1&2 span 3 span 4 span 1&2 span 3 span 4 span 100 MPH 16'-2" 19'-11" 20'-4" 15'-2" 19'-4" 19'-8" 11'-5" 14'-8" 14'-11' 12'-10" 15'-10" 16'-2" 4'-0" 110 MPH 15'-8" 19'-11" 20'-4" 14'-1" 18'-3" 18'-8" 10'-9" 13'-8" 13'-11" 11'-7" 14'-11' 15'-2" 4'.0" 120 MPH 14'-9" 19'4" 19'-8" 13'-6" 17'-5" 17'-9" 10'-2' 12'-11" 13'-2" 10'-11' 13'-11' 14'-3" 4'-0" 123 MPH 14'-7" 18'-10" 19'-2" 13'-3" 16'-5" 17'-5" 9'-11" 12'-8" 12'-11" 10'-9" 13'-9" 14'-0" 4'-0" 130 MPH 14'-1' 17'-10" 18'-2" 12'-10" 15%10" 16'-2" 9'-8" 12'-3" 12'-6" 10'-5" 13'-3" 13'-6" 3'-11" 140 MPH 11'-2' 13'-10" 14'-1" 11'-2" 13'-10" 14'-1" 9'-2" 11'-4" 1l'-7" 9'-11" 12'-8" 12'-11" 3'-9" 150 MPH 11'-2" 13'-10" 14'-1" 11'-2" 13'-10" 14'-1" 8'-9" 10'-10" 11'-1' 9'-5" 11'-8" 12'4" 3'-7" 3" x 12" x 0.050" 2 or 5 Rib Riser Panels I Glass Rooms Wind Region Open Structures Mono -Sloped Roof Screen Rooms Attached Covers Partially Enclosed Enclosed Overhang I Cantilever All Roofs 1&2 span 3 span 4 span 1&2 span 3 span 4 span 1&2 span 3 span 4 span 1&2 span 3 span 4 span 100 MPH 18'-10" 23'4" 23'-9" 18'-3" 22'-7" 23'-0" 13'-11" 17'-8" 18'-0" 14'-11" 19'-2" 19'-7" 4'-0" 110 MPH 18'-10" 23'-4" 23'-9" 16'-6" 21'-4" 21'-9" 17-11" 15'-11" 16'4" 14'-l" 18'-2" 18'-7" 4'-0" 120 MPH 18'-3" 22'-7" 23'-0" 15'-10" 20'-4" 20'-9" 11'-11" 15'-l" 15'4" 13'-3" 16'4" 17'-6" 4'-0" 123 MPH 17'-10" 21'-11' 22'-5" 15'-6" 17-11' 20'4" 11'-8" 14'-10" 15'-2" 13'-0" 16'-l" 16'-5" 4'-0" 130 MPH 16'-6" 20'-10' 21'-3" 14'-11" 19'-2" 19'-7" 11'-3" 14'4" 14'-7" 12'-7" 15'-6" 15'-10" 4'-0" 140 MPH 13'-1' 16'-2" 16'-6" 13'-1" 16'-2" 16'-6" 10'-9" 13'-8" 13%11" 11'-7" 14'-10" 15'-1" 4'-0" 150 MPH 13'-1' 16'-2" 16'-6" 13--1" 16'-2" 1 16'-6" 10'-3" 13'-1" 13'4" 11'-0" 14'-1" 14'-5" Note: Total roof panel width = room width + wall width + overhang. Lawrence E. Bennett, P.E. CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE (386) 767A774 FAX (386) 767-6556 PAGE f COPYRIGHT 2003 7.22 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. 0 k . " SCREENED ENCLOSURES I SECTION 1 Table 1.4 Allowable Post / Girt / Chair Rail Spans, Header Spans & Upright Heights For Secondary Screen Wall Frame Members Aluminum Alloy 6063 T-0 For 3 second wind gust at velocity of 120 MPH or an applied load of 14 # / sq. ft.' A. Sections As Horizontals Fastened To Posts With Clips Hollow Sections Tributary Load Width 'W' 3'-0' 1 4'-0" 1 4'-6" 1 5'-0" 1 5'-6" 1 6'-0" 1 6'-0" Allowable Heights 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 6'-10' d 6'-6" b 6'-l" b 5'-9" b 5'-6" b 5'-3" b 5'-0" b 2" x 2" x 0.055" T-3" d 6'-11" d 6'-8" b 6'4" b 6'-0" b 5'-9" b 5'-6" b 3" x 2" x 0.045" 7'-9" d 7'-5" d 7'-1" d 6'-10' d 6'-7" b 6'-4" b 5'-11" b 2" x 3" x•0.045" 4 "at— 9'-4—b 8'-9" b 8'-3" b 7'-10' . b 7'-5" b 7'•2" b 6'-9" b 2" x 4" x 0.050" 1 10'-3" b 9'-7" b 9'-0" b 8'-7" b 8'•2" b 7'-10" b 7'-5" b Snap Sections I Allowable Heights 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 1 7'-6" d 1 7'-2" d 1 6'-11" d 1 6'-8" ' b 1 6'4" b 1 6'-1" b 1 5'-9" b B. Sections As Horizontals Fastened To Posts Through Side Into Screw Bosses Hollow Sections Tributary Load Width'W' 3'-0' 1 4'-0" 1 4'.6" 5'-0" 1 5'.6" 1 6'-0" 1 6'-8" Allowable Hei hts 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 7'-9" b1 7'-3" b 1 6'-10- b 6'-6" b 1 6'-2" b 5'-11- b 5'-7" b 2" x 2" x 0.055" 8'-5" b1 7'-11" b 1 7'-5" b 7'-1" b 1 6'-9" b 6'-5" b 6'-1" b 3" x 2'_x .045" 9'-3"- 8" b 8'-2" b 7'-9" b 7'-5' b 7'-1" b 6'-8" b X - b 9" 4" b 7'-11" b 7'•7" b 2" x 4" x 0.050" 11'-6" bl 10'-9" b I 10'-l" b 1 9'-7" b 1 7-2" b 8'-9" b 8'4" b Snap Soctions Allowable Heights 'H' / bending 'b' or deflection 'd' 2" x 2" x 0.044" 9'-2" b 1 8'-7" bT 8'-1' b 1 7'-8" b 1 7'-4" b 1 7'-0" b I 6'-8" b For allowable heights at wind velocities other than 120 MPH, see conversion table 1A on the specifications for tables page at the beginning of this section and example below. Notes: 1. Thicknesses shown are "nominal" industry standard tolerances. No wall thickness shall be less than 0.040". 2. Using screen panel width 'W' select girl lengths. 9 3. Site specific engineering required for pool enclosures over 20' in mean roof height. 4. Span is to be measured frorn center of beam and upright connection to fascia or wall connection. 5. Chair rails of 2" x 2" x 0.044" min. and set @ 36" in height can be considered as residential guardrails provided they are attached with min. (3) #10 x 1-1/2" S.M.S. into the screw bosses and do not exceed 8'-0" in span. 6. Girl spacing shall not exceed 6'-8'. 7. Spans may be interpolated. IF HEIGHTS FOR'C' EXPOSURE CATAGORY AND/OR WINDZONES OTHER THAN 120 MPH ARE REQUIRED, SEE EXAMPLE ON SPECIFICATION PAGE FOR TABLES AT THE BEGINNING OF THIS SECTION. Lawrence E. Bennett, P.E. CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214368, SOUTH DAYTONA. FL 32121 TELEPHONE (386) 767-4774 FAX (386) 767-6556 PAGE COPYRIGHT 2003 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E BENNETT, P.E. 1 -57 SECTION 1 SCREENED ENCLOSURES 1/4" x 6" RAWL TAPPER THROUGH 1" x 2" AND ALUMINUM FRAME SCREENROWLOCKINTOFIRST I WALL COURSE OF BRICKS CAP BRICK ALTERNATE CONNECTION OF BRICK KNEEWALL TYPES' SCREENED ENCLOSURE FOR MORTAR REQUIRED FOR BRICK OR OTHER NON- - LOAD BEARING BRICK WALL STRUCTURAL KNEE WALL 4" (NOMINAL) PATIO 1" WIDE x 0.063" THICK STRAP CONCRETE SLAB W/ 6 x 6 - @ EACH POST FROM POST TO — 10 x 10 WELDED WIRE MESHFOOTINGW/ (2) #10 x 3/4' ° OR FIBER MESH CONCRETES.M.S. STRAP TO POST AND a — 1)1/4" x 1-3/4" CONCRETE ° ANCHOR TO SLAB OR (3) #30 BARS OR (1) 50 BAR W/ 2-1/2" COVERFOOTING ( TMP ) BRICK KNEEWALL AND, FOUNDATION FOR 'SC REENMALLS' SCALE: 3/4" = V-0" (3) #3 BAR CONT. OR 2) #3 BAR CONT. OR ( 1) #5 BAR CONT. 2'-0" MIN. 3-1/2" (TYP. (1) #5 BAR CONT. _ °_ BEFORE SLOPE ALL SLABS) C 111l7 I I I=I I IEil J -1— — I, .Ii11 F M=1IiITi=1i1=1s" 1'-0" ti.— TYPE I TYPE 'll TYPE III FLATSLOPE / NO FOOTING MODERATE SLOPE FOOTING STEEP SLOPE FOOTING 2" / 12" - V-10" > V-10" Notes: 1. [No footing required except when addressing erosion until the slab width in the direction of the primary exceeds32,ft., then a type II footing is required under the load bearing wall only unless the side wall exceed16ft. in height or the enclosure is in a "C" exposure category in which case a type II footing isrequiredforallwalls. 2. The foundations shown are based on a minimum soil bearing pressure of 1,500 PSF. Bearing capacityofsoilshallbeverified, prior to placing the slab, by field soil test or a soil testing lab. 3. The slab / foundation shall be cleared of debris and roots and compacted prior to placement of concrete. 4. Monolithic slabs and footings shall be minimum 2,500 psi concrete with 6 x 6 - 10 x 10 welded wire meshorfibermeshmaybeusedinlieuofmesh. 5. If local building codes require a minimum footing, use type II footing or footing sections required by localcode. Local code governs. SLAB - FOOTING DETAILS SCALE: 3/4" = V-0" Lawrence E. Bennett, P.E. CIVIL ENGINEER - DEVELOPMENT CONSULTANT P. O. BOX 214368. SOUTH DAYTONA. FL 32121 TELEPHONE ( 385) 767-4774 FAX ( 386) 767-056 PAGE COPYRIGHT 2003 1- 52 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. SENNETT. P.E. SECTION 1 SCREWS OR THRU-BOLTS SEE SECTION 9) 1" x 2" EXTRUSION ANCHOR TO CONCRETE W/ CONCRETE ANCHORS WITHIN' 6" OF EACH SIDE OF EACH POST AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 SCREENED ENCLOSURES POST SIZE 2" x 4" MAX. MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 WELDED WIRE MESH OR F MESH CONCRETE POST TO PLATE TO CONCRETE DETAIL SCALE: 3" = V-0" 2" x 2" x 0.063" ANGLE EACH SIDE ATTACH TO POST AND CONCRETE @ LOAD BEARING WALL W/ (2) MIN. S.M.S. (PER SECTION 9) EACH SIDE MIN. 3-1/2" SLAB 2500 P.S.I. CONCRETE 6 x 6 -10 x 10 ED WIRE MESH OR FIBER MESH CONCRETE ANGLES AS SHOWN ABOVE MAY BE USED TO CONNECT CHAIR RAILS AND PURLINS POST SIZE 2" x 4" MAX. (SEE TABLE) 1" x 2" EXTRUSION ANCHOR T( CONCRETE W/ CONCRETE ANCHORS 6" MAX. EACH SIDE OF EACH POST AND @ 24" O.0 MAX. OR THROUGH ANGLE AND @ 24" O.C. MAX. SELECT CONCRETE ANCHORS FROM SECTION 9 ALTERNATE -POST TO BEAM -AND, PLATE TO CONCRETE DETAIL r , - SCAL'E:-3" =1'-0" Lawrence E. Bennett, P.E. CIVIL ENGINEER - DEVELOPMENT CONSULTANT P.O. BOX 214358, SOUTH DAYTONA. FL 32121 TELEPHONE (366) 7674774 FAX (386) 767-6556 PAGE COPYRIGHT 2003 1 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E.