HomeMy WebLinkAbout210 W Lake Mary Blvd (3)Permit #
Job Address:
Description of Work: &,,1 AI�te Lti Lt; lel / Mhz iq, (-[./> 40
Historic District: Zoning: Value of Work: _,
Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool 40
/c vc� t�/ a0 Vatg;W ; ho-& - UP
Electrical: New Service - # of AMPS ��Addition/Alteration Change of Service Temporary Pole - Pxi S -{z
Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets
Occupancy Type: Residential Commercial Industrial _
Construction Type: # of Stories: # of Dwelling Units:
Plumbing Repair - Residential or Commercial
Total Square Footage:
Flood Zone: (FEMA form required for other than X)
Parcel #: / / - ,v2O - 30-5/9 - 0000 - O O 50 (Attach Proof of Ownership & Legal Description)
Owners Name & Address: S�vt't �(t tn� 004. � S feed?
5;a,aA,2nCL . F L 3 .2V� �- 1 Phone: �y 0 �- - -;a I- w o - n o
Contractor Name & Address: CO3=,n4,n L 6e -Ar -\j 1 C�5 � %X1 O- - � F I axL oLau
A1Dn: - S . (. a nd kLeind_ 9Iyd- * R:? -'DP I aa -yl _ F L State License Number: e5 0q 000 a :?-D
Phone Fax 3 g�e - 4 --?-5- tS 9 Contact Person: ��i-ROL 6Til-WEE_ Phone: is(, / -OI �p rJ
Bonding Company: 6'
Address:
Mortgage Lender: .
Address:
Architect/Engineer:
Address:
Phone:
Fax:
Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
Signature of OwneAAgent 6atp Signature yoff Cont ctorr//Ag%ent P Date
gj
Print Owner/Agent's am Print ontractor/Agent's Na 7
pI�
l
ature of Notary -State of Florid Date Signatu � ,pfP4gtary-FLtbte;q�&kiiOE GRAVE
Date
EA DEG ..... �� F Htn C
ao&'O * Fy GOO SSION DD `1642W* MY COMMISSION f DD 164260
:November 12,2006 EXPIRES: November 12, 200E
O 1s EX FI � Me or ontraCFp gent t B 4�d lsti 1S5911j�rKi d%6'io Me or
�+pOwe
ID1O roduced I 5.
APPLICATION APPROVED BY: Bldgg� � I -�S !�3Loning: £4� Utilities:
(Initial & Date) (Initial & Date)
Special Conditions:
FD:
(Initial & Date) (Initial & Date)
tik to 'V.� s�aRu eM a o Crwlr plo�' U-• 1tJ -
i
July 7, 2003
City of Sanford
Building Department
P.O. Box 1788
Sanford, FL 32772
RE: Boulevard Plaza - City of Sanford
Corner of 17-92 & Lake Mary Boulevard
Dear Sir/Madam:
This letter will authorize Sign -A -Rama and General Services of Central Florida and/or their agents
to pull necessary permits to install a store front sign for A Tropical Spray Tan (Unit #210) at the
above referenced shopping center.
Please feel free to contact me if you have any questions.
Sincerely,
SANDEFUR & ASSOCIATES, INC.
a a, UcG'
Tamera T. Patitucci
Executive Vice President
TTP/ks
SWORN T04ND SUBSCRIBED BEFORE
ME THIS L DAY OF JULY, 2003 *-
- &,
Kathleen E. Stanley - Notary
WUMVP KATHLEEN E STANLEY
or Vfr1 MY COMMISSION # cc9u9119
EXPIRES: Feb&2(XM
b6E�81bRARIF Fla 1b1ev swvm= a n r se. t-
806 East 25th Street ■ Sanford, Florida 32771 ■ Phone: (407) 321-8200 ■ Fax: (407) 321-9773
0 Website: www.sandefurco.coni 0
POWER OF ATTORNEY
Date:
I hereby name and appoint Carol Gauthier of General Services of
Central Florida to be my lawful attorney in fact and act for me and
apply to Gam 4.&nd for the purpose of 1444m
and to sign my name and do all things necessary to secure a permit
for the property address below.
•• Name • •Address:
&Vot
Alan Grimsl y i
General Services of Central Florida
ES# A000270
Acknowledge:
State of Florida County of 0S' -a
Affirmed and subscribed before me this day of 5 20.93, personally
appeared before me Alan Grimsley wh is --i prsonally known to me r who has
produced as identifica Ion.
�► l!�-� v LOpINOA SAUNDERS
*NoaPublic ••• MY COMMISSION t CC 898224
EXPIOES: App 24,2M4
s R f, ' eonae TWu noun Uoatwraen
My Commission Expires: -1
EXHIBIT A
(Legal Description of Property)
Lot 5, BOULEVARD PLAZA SUBDIVISION, according to the plat thereof
as recorded in Plat Book 58, Page 47, Public Records of Seminole County,
Florida.
PROPERTY I.D. NUMBER: 11-20-30-518-0000-0050
JU.—W-2003 9=;2` SANZIERP COMPANIES
f'199tG199t61p1.0 j .it Jul ?2 12 1/ 39 Xop Cuhui ! NW11On NGhJt![lf, CHU17c, ✓;L
4
i
S I T E P L A N
O! XIt:WAY n -ii - 7R li k 100 - 1/)' VARIid
91713 P. 67/ir
li 1
L.�j iKi1K'FF�i_� aeaepRaB�
UTAlfiitl PLAN e0WAVA1i0 PLAZA METAL
I GW cn lkwnfn m ran•
m
P. @r
1 I
WV W
JiiSconnec+- UL
D&4344S0
Individually illuminatee channel letters mounted on raceways painted to match fascia D 3 jp 9 S S
Overall height - 57", Overall width -T-0"
Total square footage - 33.25
Tree height - 30"
Text - Oracal 8500 Pink translucent vinyl (4041) with Green 1 jewelite trim
Treet - Avery Clover Green translucent vinyl (A9626 T) with white r jewelite trim
Sides of cans painted anodized bronze
2-o f 5�� re-YG-O^f
ROBERT WHITE, P,E,
2464 PRINCETON RD,
DELAND , FL, 32720
PH# 407-322-6630
FL. GST
PRE-ENGINEERED
ALUM, RACEWAY
BY OTHERS
4 nO SHEET
KETO L SCREWS -1
PRE-ENGINEERED
CHANNEL LETTER
BY OTHERS
3/8'X5' LAG
SCREWS AT
48' O.C. TOP L
BUT INTO EXIST.
STUD. 3/8' DIA.
TOGGLE DOLT OR
THRU BOLT MAY
BE SUBSTITUTED
STUCCO OR EIFS
ON 1/2' PLYWOOD
ON WOOD OR MTL
STUDS
FRAME WALL MOUNTING DETAIL
3/4'=1'-0'
NOTESs
GSC- CHANNEL LETTERS
JOB ON RACEWAY WALL SIGN
SHEET NO
1
OF
1
CALCULATED
BY WDD
DATE
7-11-03
CHECKED BY
RW
DATE
7-11-03
SCALE
8PP- —OW
JOB#
30214
PRE-ENGINEERED
ALUM. RACEWAY
BY OTHERS
I SHEET
SCRE 's
3/8'X5' LAG
SCREWS IN
WEDGE ANCHORS
OR 3/8' DIA
THRU BOLTS
TOP L BUT AT
48' O.C. MAX
• 7 nl a •u.
r ! a•
HOLLOW BLOCK WALL MOUNTING DETAIL
OR SOLID CONCRETE WALL
NOTE, THE LETTER SHOWN HERE 'T' IS DIAGRAMATIC
AND IS USED TO SHOW TYPICAL ANCHORAGE. ACTUAL
LETTERS USED WILL RECEIVE TYPICAL ANCHORS
30' MAX
1110 SHEET METAL
SCREWS
PRE-ENGINEERED
CHANNEL LETTER
BY OTHERS
3/8'X5' LAG SCREWS OR
WEDGE ANCHOR NOT TO
EXCEED 48'O.C.
PRE-ENGINEERED
ALUM. RACEWAY
BY OTHERS
CHANNEL LETTER ATTACHMENT TO RACEWAY
3/4'=1'-0'
1. Design wind pressure In conformance with Florida
Bullding Code,2001 ed., 120 mph reglonC 32.63 psf).
2. Anchorst BY HILTI
3. Contractor shall be responsible for all
waterproofing.
4. Pre-engineered sign face by others. Delegate
englneer shall provide design drawings to Robert White,
P.E. for approval prior to fabrication or erection.
WIND IMPORTANCE CRITERIA
WIND VELOCITY
IMPORTANCE FACTOR
EXPOSURE CATEGORY C MVRF >
INTERNAL PRESSURE COEFFICIENT
COMPONENT L CLADDING PRESSURES
FORCE COEFFICIENT Cf
PLANS REVIEWED
CITY OF SANFORD
5
PERMIT #o3•�fp(