HomeMy WebLinkAbout250 W Lake Mary Blvd (2)7�
,�� CITY OF SANFORD PERMIT APPLICATION
41mm —4
Permit No.:�7 _ Date: / U
Job Address: 49�0 U)- Zr elm - --�—
Permit Type: ./ Building Electrical _ Mechanical Plumbing Fire Alarm/Sprinkler
Description of Work:
Additional Information for Electrical & Plumbing Permits
Electrical: _Addition/Alteration _Change of Service Temporary Pole _New AMP Service (# of AMPS )
Plumbing/Residential: Addition/Alteration New Construction (One Closet Plus Additional)
Plumbing/Commercial: Number of Fixtures Number of Water & Sewer Drainage Lines Number of Gas Lines
Occupancy Type: Residential
Type of Construction:
1-6-mmercial_ Industrial Total Sq Ftg: Value of Work: $ 4 �ao
Flood Zone: Number of Stories: Number of Dwelling Units:
Parcel No.: LI d O- 30 -X18 - 00 V0 O_o S -a _ (Attach Proof of Ownership & Legal Description)
Owner/Address/Phone: Sih? �viL A:&s oou 4-r,,J'
Contractor/Address/Phone: �AVCO S
3.)771 (07) 3,W- �,�oo
l" " State License Number:S Ord 3�8
Contact Person: ��Ct77TIG� Inoolay Phone & Fax Number: 7f Z C
Title Holder (If other than Owner):
Address:
Bonding Company:
Address:
Mortgage Lender:
Address;
Architect/Engineer �w&E %i gL(Ad Phone No.:
Address: i/[/�O lG • -1'1l(gf- -S-t— �/ � �� 3.)771 Fax No.:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS,
POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with
all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as
water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
s�3
Signature of Owner/Agent Date Si a of Contractor/Agent Date
Print Owner/Agent's Name Print Con ac A nt's Name
Signature of Notary -State of Florida Date Signa ure of Notary -State of Florida Date
Owner/Agent is _
_ Produced ID
Personally Known to Me or
LINDA D. EVANS
Notary Public, State of Florida
My comm, exp. Ja ,
Comm. No. D 180505
Contractor/Agent is Personally Known t Me or
Produced ID
APPLICATION APPROVED BY: �Gc`S- Date:
Special Conditions:
b ,, IS
4 - 5--2
ESTABLISHED 1976
May 13, 2003
City of Sanford
Building Department
P.O. BOX 1788
Sanford, FL 32772
RE: Boulevard Plaza - City of Sanford
Corner of 17-92 & Lake Mary Boulevard
Dear Sir/Madam:
This letter will authorize Jayco Signs to pull necessary permits to install a store front sign for Town
Jewelry (Unit 4250) at the above referenced shopping center.
Please feel free to contact me if you have any questions.
Sincerely,
SANDEFUR & ASSOCIATES, INC.
Tamera T. Patitucci
Executive Vice President
TTP/ks
SWORN TO AND SUBSCRIBED BEFORE
ME THIS 1,3-A DAY OF MAY, 2003
KATHLEEN E STANLEY
Jlc��,6W
.e MY COMMISSION # CC 909119
1 EXPI RES: Feb 8.2(04
Kathleen E. Stanley - Notary Pu li ', p OTARY FIs. Notary ServicesBonding Co.
LINDA 0. EVANS
Notary Public, S9;^cc of Florida
My comm. exp. dlarl. 27, 2007
Comm. Noo.. DD '180505
U /"`^° P , '�Z"
806 East 25th Street ■ Sanford, Florida 32771 ■ Phone: (407) 321-8200 ■ Fax: (407) 321-9773
0 Website: www.sandefurco.com ■
EXHIBIT A
(Legal Description of Property)
Lot 5, BOULEVARD PLAZA SUBDIVISION, according to the plat thereof
as recorded in Plat Book 58, Page 47, Public Records of Seminole County,
Florida.
PROPERTY I.D. NUMBER: 11-20-30-518-0000-0050
LAYOUT
SCALE:
ELEVATION
NTS
END VIEW
rJTS
RA
NI
ABRICATED ALUMINUM CHANNEL LETTERS PAINTED WITH MATTHEWS ACRYLIC URETHANE ENAMEL: SATIN
MOu ISH
LACKS & RETURNS:.050" ALUMINUM RETURNS AND .063" ALUMINUM BACKS PAINTED BRONZE
ACES: 1/8" WHITE PLEXIGLASS WITH FIRST SURFACE APPLIED RED VINYL (LETTERS TO HAVE A 3/8" INSET WHITE
ORDER) ALL TO HAVE RED JEWELITE TRIM
LLUMINATION: 15mm RED NEON OR LED CHANNEL LITES WITH RACEWAY MOUNTED TRANSFORMERS
QUARE FOOTAGE: S
TORE FRONTAGE: 15'
NUMBER OF SETS: 1 -14
FACE COLOR: WHITE WITH RED VINYL
RETURN COLOR: BRONZE Es 0000208
TRIM COLOR: RED ULE 141005
RETURN DEPTH: 5"
NEON OR LED COLOR: RED
RACEWAY COLOR: TO MATCH FASCIA
REO
JEwEtM
BONZE
m"is
Listed sign or sign section (consists of
channel letters attached to raceway ice/
electrode receptacle, transformer lube
stands and disconnect switch, if -4_ peptic
provided) suitable Icr outdoor location varies
unless marked for Indoor only.
R —
Plastic face -- ►
(optional)
Tube support
per NEC 600-33(b).
Neon tube.
Spacings maintained
Letter per spacing table.
height
varies
Electrode
receptacle
t
Drain holes
It used outdoors.
t
---- Groundod conllnuous sheet metal
raceway wilh sheaf metal cover.
Listed disconnect switch in primary
to be within sight (maximum 50 II.) of sign.
(Switch may be Integral with sign as shown.)
NEC 110-3(b), 600-2, 600-4.
r ,
r ,
r ,
r ,
r ,
U
� r
SPACING TABLE
A. Between primarywiring and insulated high vollage wiring.
0. Between Insulated high voltage wiring and dead metal where wiring
parallels dead metal for more than 1' within sign sections.
C. Between neon tube (if over 7500voll circuit) and nearest surface.
D. Between uninsulated high voltage conductors or components. (Md -
point -grounded transformer) and dead metal (ground), low voltage
circuit conductors and high voltage conductors of opposite polarity.
Voltage
A
B
C D
1001 10 5000
12 inch
1/2 inch
none 3/4 in
5001 to 10000
3/4 inch
3/4 Inch
114 Inch if 1-1/8in
7500V+ 1-12in
10001 to 15000
1 inch
1 inch
Primary electrical source
(1/2 In. minimum conduit,
metal shown).
NEC 6006 d 60021.
Transformer
Example 'A'
One p e1 ce
sign
i
Example'8'
Two piece
sign
UVV(1Q3 Example 'C'
Two signs
Fasteners as required
by local Jurisdiction.
LISTED All ti h y py k1 y
Listing marks: n Is reserved. No pail nl this work covered b the co r hl hereon nu
Sign or section listing mark. by qualified electrical be reproduced or used In any lona or by any means - graphic, declronic, of
testing laboratory mechanical. Including pholocnpying, recording, taping, or information slorage
Sol examples
on sign B.
sections, g ry anti retrieval systems - without written permission of the publisher, except
Sol •xamples'A, e, b C. ELECTRIC SIGN SECTION that single copies or individual pages may be made by a bona lid* electrical
The first blank space Identifies the number of NO. XX -123456 sign lnstallallon Ihm tot the sole propose or provlding guidance on the
ns or outline lighting, without the pernllsston
each sign section. The second blank space in,IJIIJ1ion or etectrtcal sigor The
Indicates the total number of sign secllons. of� publisher.
t
Raceway
BOBS
(Sign Iisling mark)
Jolnl In
raceway
BIG BOB'S
Two raceways —�
connecledtogether
(Iwo seCtton listing mark)
BIG BOBS
�— Separate raceway —�-
for each sign
(one sign listing mark on each sign)
Installation of signs listed per UL48
Nola: Installation requirements only.
Manufacturing requirements contained in UL48
ILLUMINATED CtfANNEL LETTER
CONTINUOUS RACEWAY
GLASS ELECTRODE RECEPTACLE
Dale: October 1994
Scale IAEI UL48-T3
None Dwg. No.
6