Loading...
HomeMy WebLinkAbout3101 1 St (2)00 CITY OF SANFORD PERNDT APPLICATIONy Permit No.: V 3 _60(0 Date: APRIL 2, 2003 Job Address: 3101 FIRST STREET, W SANFORD, FL 32771 Parcel No.: 26-29-30-5AE-33OA-0000 (Attach Proof of Ownership & Legal Description) Description of Work: ADD ONE HEAD IN RECEPTIONIST AREA Type of Construction: FIRE SPRINKLER SYSTEM Valuation of Work: $ 300.00 Flood Zone: Occupancy Type: Residential X Commercial Industrial Number of Stories: Number of Dwelling Units: Zoning: Total Square Footage: Owner: CENTRAL BAPTIST CHURCH OF SANFORD Address: 3101 FIRST STREET, W SANFORD, FL 32771 City: SANFORD State: FL Zip: 32771 Phone No.: Fax No.: Contractor: WAYNE AUTOMATIC FIRE SPRINKLERS, INC Address: 222 CAPITOL COURT City: OCOEE State: FL Zip: 34761 State License No.: 90293400022002 Phone No.: 407-877-5588 Fax No.: 407-656-8026 Contact Person: BECKY ROMEA / CHRIS MOSS PhoneNo.: 407-877-5588 Title Holder (If other than Owner): Address: Bonding Company: Address: Mortgage Lender: Address: Architect: Address: Phone No.: Fax No.: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner Signature of Owner/Agent Date i i Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is _ Produced ID Personally Known to Me or APPLICATION APPROVED BY: 1,0, 6 /S. - Special Conditions:Fire Dept ----,��. Date of the requ4men-V of Florida Lien Law, FS 713. ;!g�� �4-2-03 of Contractor/Ag nt I Date PETE SCHWAB Print Contractor/Agent's Name ex & "Vdml� 4-2-03 Signature of Notary -State of Florida Date REBECCA S. ROMEA Notary Public, State of Florida My comm. expires JJuly _ 853720 Bonded thru Ashton Agency, Inc. Contractor/Agent is XX Personally Known to Me or Produced ID -5- 3 'r WAYNE Automatic Fire Sprinklers, Inc. �t •art'. `" LETTER OF AUTHORIZATION% Date: April 9,'2003 TO: City of Sanford Re: Central Florida Baptist Church (3101 West State Road.46) This letter is to authorize Joel Setzer to hand deliver, pick-up and/or sign for our permit for the above referenced project on my behalf. Thank You! 1 , P er T. Schwab State License #90293400022002 Before me personally appeared Peter T. Schwab, to me well known and known to.. me to be the person described in and who executed the foregoing instrument. Witness•my hand and official seal this 9th day.of April , 20 03 MY COMMISSION EXPIRES:' Signature of Notary i Rt>TMn MCCuuACH Ruth A. McCulloch MY COMMISSION # OD 095595 Name of Notary typed or printed EXPIRES: February 26,20D6 Pf .^ Banded TWu NoWry PUW Und""$ Corporate Office:•222 Capitol Court • Ocoee, Florida 34761-3033 • (407) 656-3030 • FAX (407) 656-8026 Regional Offices: Jacksonville • . Fort. Myers • Pompano -Beach • Concord, NC CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: A�3-- BUSINESS NAME / PROJECT: ADDRESS: '� 10 PHONE NO.: I '-f n-71 % 7 7-_ A—PERMIT #: NO.: CONST. INSP. [ ] / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW INY F. A. [ ] F.S. (A HOOD [ ] PAINT BOOTH [ ] BURN PER IT [ ] TENT PERMIT ] I �((i�_TANK PERMIT [ ] OTHER [ ] TOTAL FEES: $ (PER UNIT SEE BELOW) Address / Bldg. # / Unit # Sauare Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. , 6.7. 'l 8. V` 9. 10. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florid .� l Sanford Fire Prevention Division Ap s Signature WWAYNE 222 CAPITOL COURT, OCOEE FL 34761 407-656-3030 FAX #407-656-8026 LETTER OF TRANSMITTAL To: CITY OF SANFORD 300 N PARK AVENUE SANFORD, FL 32771 Attn: PLANS REVIEW Phn: 407-330-5600 ENCLOSED YOU WILL FIND: Date: April 2, 2003 Job#: 63069 Re: Central Florida Bapitst Church 3101 W First Street Sanford, FL Parcel ID#: 26 19 30 5AE 330A 0000 COPIES DATE DESCRIPTION 3 SETS OF PLANS 3 SUBMITTAL DATA 1 PERMIT APPLICATION 1 LEGAL DESCRIPTION X For approval For your use As requested For review and comment p Wayne Automatic Fire Sprinklers is performing the work at tht above referenced location at no charge to church. REMARKS: Please return two (2) sets with your seal of approval and/or comments. Please call 407-877-5588 when permit is ready and -give amount. Signed: Becky Romea .z� Tax Info Ray Valdes Seminole County Tax Collector Property Tax Information Tax Estimator Back to Search Options Current 2002 Millage Rates Page 1 of 1 The Information contained herein does not constitute a title search and should not be relied on as such. Parcel 26-19-30-5AE-330A-0000 Number: Owner & Address: CHURCH CENTRAL BAPTIST OF SANFORD 3101 FIRST ST W SANFORD FL 32771 Requester IP: Date: 4/1/2003 209.208.42.184 Tax Year: 2002 Total Assessed $2,529,558 Value: Taxable Value: $0 Gross Tax Amount: $0.00 Millage Code: S1 SANFORD Exemptions: Questions About Exemptions? Widow, Disability, or $2,529,558 Other: Homestead: Map and Property_ Appraiser Information Legal Description: LEG E 1/2 OF BLK 33 + E 1/2 OF N 210 FT OF BLK 34 + W 1/2 OF N 210 FT OF BLK 47 + W 1/2 OF BLK 48 (LESS RD) Current Tax: Amount Due: *NONE* Date Receipt Num. Amount Paid Date Receipt Num. Amount Paid Non -Ad Valorem Assessments: *NONE* Unpaid Delinquent Taxes: *NONE* Year Cert # Current Payoff If Paid by* Next Payoff If Paid by* Other Comments: * UNPAID DELINQUENT TAXES MUST BE PAID BY A CASHIERS CHECK, MONEY ORDER, DEBIT CARD OR CERTIFIED FUNDS AND ARE DUE BY THE LAST BUSINESS DAY OF THE MONTH. http://www.seminoletax.orgldev/result.asp?txtAccountlD=26-19-30-5AE-330A-0000 4/1/2003 PRODUCT DATA SUBMITTAL CENTRAL FLORIDA BAPTIST CHURCH 3101 WEST STATE ROAD 46 SANFORD, FLORIDA WAYNE AUTOMATIC FIRE SPRINKLERS, INC. 222 CAPITOL COURT - OCOEE, FL 34761 TEL (40""7) 656-3030 or FAX (407) 656-8026 Model H Recessed 5.Mactor •. Standard Response EENTRAV Standard Coverage Recessed Pendent Fusible Solder Type Sprinkler Tyco Fire Products --- www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Fire Protection Association, in addition General to the standards of any other authorities having jurisdiction. Failure to do so may Dtiimpair the integrity of these devices. escrep on The Central Model H, 5.6 K -factor Recessed Pendent Sprinklers are automatic sprinklers of the fusible solder type. They are standard response - standard orifice spray sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recog- nized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Central Model H Recessed Pendent Sprinklers incorporate a center strut mechanism with a special two- piece recessed escutcheon assembly permitting 1/2" of field -adjustment. Unlike most other recessed sprinklers, the upper escutcheon support piece is factory installed on the base of the sprinkler frame, assuring a Listed installation. The ceiling escutcheon plate is easily installed after the sprinkler is in place either by the standard 'push -on" escutcheon or the special "thread -on" escutcheon. This feature allows removal of ceiling panels for easy access to ceiling equipment without taking the system out of service to remove the sprinkler. Operation: A fusible alloy is sealed into a bronze actuating rod (center strut) by a stainless steel ball. When the alloy melts at its rated temperature, the ball is forced upward into the center strut, releasing the two ejectors and operating the sprinkler. WARNING The Model H Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Sprinkler Identification Number SIN C3711 Approvals UL & ULC Listed. FM & NYC Approved (Refer to Table 1. The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) 250 psi (17,3 bar) UL & ULC Pipe Thread Connection 1/2 inch NPT Discharge Coefficient K = 5.6 GPM/psi'n (80,6 LPM/bar'rz) Temperature Ratings 165'Ff74'C or 212°F/100°C Finishes Sprinkler: White Polyester, Chrome Plated, or Natural Brass Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics The Model H Recessed Pendent Sprinklers utilize a dezincification resistant (DZR) bronze frame and a brass deflector. The waterway is sealed with copper seal disk, and the fusible assembly is con- structed of bronze and stainless steel components. Standard Spray Recessed Pendent Sprinklers No. 1-3.0 I Figure 1 - Model H Recessed Sprinkler with Push -on Escutcheon I � t / \ 2-7/4-(69.9 mm) Max. / FACE OF SPRINKLER T2 -V2'(63,5 mm)Mu+ / / FITTING I I WRENCH FLAT 1'-1/4- (25 4mm m 6 dmm) � \°\, 81 Sit ESCUTCHEON (27.8 mm8amm FINISHED CEILING AP CAP 1^ 1 -1 (25.4 mm) SUPPORTACTUATING 3.1/4' (82,8 mm) CUP Figure 3 - Cross Section Model H Recessed Sprinkler Figure 2 - Model H Recessed Sprinkler with Threaded Escutcheon I I 1 / \ 2-3/4'(159.9 mm) Max. / FACE OF SPRINKLER _r 2-1/2' (63,5 mm)Min FITTING I ( —I —( WRENCH FLAT FINISHED 15/16'3114' CEILING (23,8 mm3 6.4 mm)I 1' (25.4 mm) 3-1/4' (82,6 m� Figure 4 - Universal Wrench (Part #1122) Figure 5 - Recessed Escutcheon Tool (Part#10654000) SEAL DISK AL SE AP CAP SUPPORTACTUATING CUP ROD �. O. SPRINGSPRINKLER I�i . .-..-.. r�aW...-.«.MO�DEIL FRAME: A/H RECESSED DEFLECTOR ESCUTCHEON Figure 2 - Model H Recessed Sprinkler with Threaded Escutcheon I I 1 / \ 2-3/4'(159.9 mm) Max. / FACE OF SPRINKLER _r 2-1/2' (63,5 mm)Min FITTING I ( —I —( WRENCH FLAT FINISHED 15/16'3114' CEILING (23,8 mm3 6.4 mm)I 1' (25.4 mm) 3-1/4' (82,6 m� Figure 4 - Universal Wrench (Part #1122) Figure 5 - Recessed Escutcheon Tool (Part#10654000) Design Criteria The Model H Recessed Pendent Sprinklers are UL, ULC Listed and MEA Approved for use in accordance with current NFPA standards. The Recessed Pendent Sprinklers are only listed with the Series A/H Recessed Escutcheon Assemblies. The Model H Recessed Pendent Sprinklers are FM Approved for use in accordance with the FM Loss Prevention Data Sheets. The Recessed Pendent Sprinklers are only listed with the Series A/H Recessed Escutcheon Assemblies. The Model H Recessed Pendent Sprinklers are availabe with a two types of support cups, one that accepts a push -on escutcheon and one that accepts a threaded escutcheons. The recessed escutcheons are manufactured out of a metal or plastic material that has been specifficaly tested and listed for use with the Model H Recessed Pendent Sprinklers. The plastic recessed escutcheon is only listed for use with the push -on support cup assembly. Do not install the Model H Recessed Pendent Sprinklers in ceilings which have positive pressure in the space above Table 1 - Laboratory Listings and Approvals Notes: 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters' Laboratories of Canada. 3. Approved by Factory Mutual Research Corporation. 4. Approved by the City of New York under BSA 375 -75 -SA 13 Installation The Model H Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. NOTES A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 fLlbs. (28,5 Nm) of torque is to be used to install 1/2 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to make up for insuffi- cient adjustment in the escutcheon plate by under- or overtightening the sprin- kler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position. The deflector is to be parallel to the ceiling, roof, or mounting surface, as applicable. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the Universal Wrench (Ref. Figure 4). With reference to Figure 1 or 2, the Universal Wrench is to be applied to the sprinkler wrench flats only. After the ceiling has been installed or the finish coat has been applied, slide on the Model A/H Recessed Escutcheon over the Model H Recessed Sprinkler and push -on or thread on the recessed escutcheon until its flange comes in contact with the ceiling. Installation of the Model A/H Reccesed Escutcheon can be accomplished by hand or by using the Recessed Escutcheon Tool (Ref. Figure 5) and a telescoping pole assembly. Every Model H Recessed Escutcheon has 4 tabs on the interior opening of the escutheon. By matching these tabs to the corresponding groove on the Recessed Escutcheon Tool and with the telescoping pole attached, the recessed escutcheon can be installed without the aid of a ladder. Care should be exercised to assure that the Actuator Rod and Ejector Springs of the sprinkler are not dammaged during the installa- tion of the recessed escutcheon. SPRINKLER FINISH Temperature Rating Frame Color Code Natural Brass Chrome Plated Polyester Coated 1650F/74°C Unpainted 1,2,3,4 1,2,3,4 1 2120F/100°C White 1,2,3,4 1,2,3,4 1 Notes: 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters' Laboratories of Canada. 3. Approved by Factory Mutual Research Corporation. 4. Approved by the City of New York under BSA 375 -75 -SA 13 Installation The Model H Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. NOTES A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 fLlbs. (28,5 Nm) of torque is to be used to install 1/2 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to make up for insuffi- cient adjustment in the escutcheon plate by under- or overtightening the sprin- kler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position. The deflector is to be parallel to the ceiling, roof, or mounting surface, as applicable. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the Universal Wrench (Ref. Figure 4). With reference to Figure 1 or 2, the Universal Wrench is to be applied to the sprinkler wrench flats only. After the ceiling has been installed or the finish coat has been applied, slide on the Model A/H Recessed Escutcheon over the Model H Recessed Sprinkler and push -on or thread on the recessed escutcheon until its flange comes in contact with the ceiling. Installation of the Model A/H Reccesed Escutcheon can be accomplished by hand or by using the Recessed Escutcheon Tool (Ref. Figure 5) and a telescoping pole assembly. Every Model H Recessed Escutcheon has 4 tabs on the interior opening of the escutheon. By matching these tabs to the corresponding groove on the Recessed Escutcheon Tool and with the telescoping pole attached, the recessed escutcheon can be installed without the aid of a ladder. Care should be exercised to assure that the Actuator Rod and Ejector Springs of the sprinkler are not dammaged during the installa- tion of the recessed escutcheon. Care & Maintenance The Model H Recessed Pendent Sprinklers must be maintained and serviced in accordance with the foiiowing instructions. NOTE S Absence of an escutcheon which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before closing a Fre protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their temperatures will exceed 100°F/ 38°C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. tgCOFlow Control Tyco Fire l Products Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ter, (10) years acainst defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by owner- ship with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EX- CEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. i nOrdering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, orifice size, temperature rating, type of finish or coating, and sprinkler wrench. Refer to price list for complete listing of Part Numbers. Teflon is a trademark of the DuPont Corp. Printed in U.S.A. 2-01 Mechanical Tees See Fre Protection Submittal Sheet for pressure rating and Listing and Approval information Technical Data Figure: 730 Outlet: Threaded & Grooved Max. Working Pressure: 300 psi (2068 kPa) Note: Maximum pressure applies to the Mechanical Tee. When connected to a grooved coupling,the rating will be the lesser of the Mechanical Tee or Coupling rating. Maximum pressure is a total from all loads, based on standard weight or Sch. 10 steel pipe. For pipe with other wall thickness or materials contact Tyco Fire Products. Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing / Approval info. Manufacturing Source: Domestic Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile =110,000 psi) Gasket: (specify when ordering) • Grade E EPOM green color code write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited li" Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTAB/LITYAND FITNESS FOR A PARTICULAR PURPOSE. No. 18-6.0 EENTRAL Tyco Fre Products --- w` w_tyro-grooved.com 451 Ncr;h Cannon Avenue. Lansdale, 'Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Tel: 381-9312 Fax: 791-5500 Grooved PipirYr,, Products Technical Services: (800) / (800) (See Gasket Grades and Recommendations when paid for and properly installed General Sheet for aid in selecting the proper gasket) and maintained under normal use and s— Description(10) Ordering service. This warranty will expire ten years from date of shipment by Tyco Fire Products. No warranty is given for products or components The Figure 730 Mechanical Tees may be used Information manufactured by companies not for anv tee connection where a threaded or affiliated by ownership with Tyco Fire grooved outlet is needed. They may be g converted into a cross when necessary. Ordering Information: When placing Products or for products and an order, indicate the full product name. components which have been subject UL UL Please specify the quantity, figure number, "E", to misuse, improper installation, corrosion, or which have not been type of gasket, EPDM and size. FM Availability and Service: Grooved installed, maintained, modified or Piping Products, valves, accessories and repaired in accordance with applicable other products are available throughout the Standards of the National Fire U.S., Canada, and internationally, through a Protection Association (NFPA), and/or network of distribution centers. You may the standards of any other Authorities See Fre Protection Submittal Sheet for pressure rating and Listing and Approval information Technical Data Figure: 730 Outlet: Threaded & Grooved Max. Working Pressure: 300 psi (2068 kPa) Note: Maximum pressure applies to the Mechanical Tee. When connected to a grooved coupling,the rating will be the lesser of the Mechanical Tee or Coupling rating. Maximum pressure is a total from all loads, based on standard weight or Sch. 10 steel pipe. For pipe with other wall thickness or materials contact Tyco Fire Products. Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing / Approval info. Manufacturing Source: Domestic Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile =110,000 psi) Gasket: (specify when ordering) • Grade E EPOM green color code write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited li" Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTAB/LITYAND FITNESS FOR A PARTICULAR PURPOSE. No. 18-6.0 Figure 730 Mechanical Outlet Tee and Cross (Threaded) B 8 WA D A TAKEOUT TAKEOUT t D E TAKEOUT A-�fel Figure 730 Mechanical Cutlet Tee (Threaded) Figure 730 Mechanical Outlet Cross (Threaded) Nom. Size Hale Dia.$ Dimensions Net Hole Max. A B C D E Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm mm Kg. 1.50 1.63 2.62 4.88 3.07 2.12 1.59 2.2 2" x'/2", 3/4',1 38.1 41.3 66.5 124.0 78.0 53.8 40.4 1.0 1.75 1.88 2.78 4.88 1 3.32 1.93 1.59 2.5 2"x 11/4' 44.5 47.6 70.6 124.01 84.3 49.0 1 40.4 1.1 1.75 1.88 2.62 4.88 3.32 1.93 1.59 2.5 2" x 1'/z' 44.5 47.6 66.5 124.0 84.3 49.0 40.4 1.1 1.50 1.63 2.88 5.25 3.07 2.38 1.81 2.7 21/2" x'/2", 1/4',1 38.1 41.3 73.2 133.4 78.0 60.5 46.0 1.2 2.00 2.13 3.00 5.25 3.56 2.19 1.81 3.1 21/2" x 11/4* 50.8 54.0 76.2 133.41 90.4 55.6 1 46.0 1.4 2.00 2.13 3.07 5.25 3.59 2.17 1.81 3.3 2,/2„ x 1'/2" 50.8 54.0 78.0 133.4 91.2 55.1 46.0 1.5 1.50 1.63 3.19 6.13 3.07 2.56 2.21 3.7 3'x'/2",'/4', 1' 38.1 41.3 81.0 155.7 78.0 65.0 56.1 1.7 1.75' 1.88 3.34 6.13 3.32 2.50 2.21 3.9 3' x 11/4 44.5 47.6 84.8 155.71 84.3 63.5 56.1 1.8 2.00 2.13 3.38 6.13 1 3.56 2.48 2.21 4.2 3"x 1'/2' 50.8 54.0 85.9 155.71 90.4 63.0 56.1 1.9 2.50 2.63 3.50 6.13 4.09 2.75 2.21 4.7 3' x 2" 63.5 66.7 88.9 155.7 103.9 69.9 56.1 2.1 1.50 1.63 3.69 7.13 3.07 3.06 2.78 5.5 4" x'/2" 3/4' 1 38.1 41.3 93.7 181.1 78.0 77.7 70.6 2.5 1.75' 1.88 3.92 7.13 3.32 3.00 2.78 5.5 4" x 1114' 44.5 47.6 99.6 181.1 1 84.3 76.2 70.6 2.5 2.00 2.13 4.00 7.13 3.56 2.98 2.78 5.5 4"x 11h' 50.8 54.0 101.6 181.1 90.4 75.7 70.6 2.5 2.50 2.63 4.00 7.13 4.06 3.25 2.78 6.0 4'x 2" 63.5 66.7 101.6 181.1 103.1 82.6 70.6 2.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 6.0 4" x 2'/2" 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 6.0 4" x 76.1 mm 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 3.50 3.63 4.13 7.13 5.13 3.31 2.78 7.0 4'x 3' 88.9 92.1 104.9 181.1 130.31 84.1 70.6 1 3.2 . - Hole size for 3' x 11/4' and 4' x 1'/4" changed from 2' previously on Figure 720. r Figure 730 Mechanical Outlet Tee and Cross (Threaded) Nom. Size Hole Dia.$ Dimensions Net Hole Max. A B C D E Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm mm Kg. 2.00 2.13 4.63 8.13 3.56 4.00 3.37 6.5 5' x 1'/z" 50.8 54.0 1 117.6 206.51 90.4 101.6 85.6 2.9 2.50 2.63 4.63 8.13 4.06 3.88 3.37 7.1 5"x 2" 63.5 66.7 117.6 206.5 103.1 98.6 85.6 3.2 2.75 2.88 4.75 8.13 4.38 3.88 3.37 7.3 5" x 2'/z" 69.9 73.0 120.7 206.5 111.3 98.6 85.6 3.3 2.75 2.88 4.75 8.13 4.38 3.88 3.37 7.3 5' X 76.1 mm 69.9 73.0 120.7 206.51 111.3 98.6 85.6 3.3 3.50 3.63 5.00 8.13 5.13 4.06 3.37 7.6 5' x 3" 88.9 92.1 127.0 206.5 130.3 103.1 85.6 3.4 2.00 2.13 5.13 9.25 3.56 4.04 3.90 7.4 6' x 1'/z" 50.8 54.0 130.3 235.0 90.4 102.6 99.1 3.4 2.50 2.63 5.13 9.25 4.06 4.31 3.90 7.5 6' x 2" 50.8 66.7 1 130.3 235.0 103.1 109.5 99.1 3.4 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 6' x 2'/z' 69.9 73.0 130.3 235.0 111.3 106.21 99.1 3.4 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 6' X 76.1 mm 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 3.50 3.63 5.50 9.25 5.13 4.37 3.90 9.5 6"x 3" 88.9 92.1 139.7 235.01 130.3 111.0 99.1 4.3 4.50 4.63 5.38 9.25 6.13 4.56 3.90 10.0 6' x 4" 114.3 117.5 136.7 235.0 155.7 115.8 99.1 4.5 2.75 2.88 6.25 12.50 4.38 5.12 4.90 10.2 8' x 2'/z" 69.9 73.0 158.8 317.5 111.3 130.0 124.5 4.6 2.75 2.88 6.25 12.50 4.38 5.12 4.90 10.2 8' X 76.1 mm 69.9 73.0 158.8 317.5 111.3 130.0 124.5 4.6 3.50 3.63 6.50 12.50 5.13 5.37 4.90 12.5 8' x 3' 88.9 92.1 165.1 317.5 130.3 136.4 124.5 5.7 4.50 4.63 6.38 12.50 6.13 5.56 4.90 12.5 8"x 4" 114.3 117.5 162.1 317.5 155.71 141.2 1 124.51 5.7 # Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/e" of the hole to be certain it is free from conditions which would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, which might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. Note: Outlet threads conforming to BSP are available, contact Tyco Fire Products for details. Figure 130 Mecha- , cal Outlet Grooved Cross Figure 730 Mechanical Outlet Tee and Cross (Grooved) Nom. Size Hale Dia.t Dimensions Net Net Wt. Hole Max. A B C E Wt. Run x Branch Inches Inches inches Inches Inches Inches Lbs. MM mm rnm mm mm rnm Kg. 1.75 1.88 2.78 4.88 3.32 1.59 2.5 2''t 1'/a" 44.5 47.6 70.6 124.0 84.3 40.4 1.1 2' x 1'/2" 1.75 1.88 2.62 8.13 4.38 1.59 2.5 44.5 47.6 66.5 +4.883.32 111.3 40.4 1.1 2.00 2.13 3.00 8.13 1.81 3.1 2'/2' x 1'/<" 50.8 54.0 76.2 206.5 111.3 46.0 1.4 2.00 2.13 3.07 5.25 3.59 1.81 3.3 21/2'x 11/2" 50.8 54.0 78.0 133.4 91.2 46.0 1.5 1.75' 1.88 3.34 6.13 3.32 2.21 3.9 3' x 1'/4' 1 44.5 47.6 84.8 155.7 84.3 56.1 1.8 2.00 2.13 3.38 6.13 3.56 2.21 4.2 3' x 11/2" 50.8 54.0 85.9 1 155.7 90.4 56.1 1.9 2.50 2.63 3.50 6.13 4.09 2.21 4.7 3' x 2' 63.5 66.7 88.9 155.7 103.9 56.1 2.1 1.75' 1.88 3.92 7.13 3.32 2.78 5.5 4' x 11/4" 1 44.5 47.6 99.6 181.1 84.3 70.6 2.5 2.00 2.13 4.00 7.13 3.56 2.78 5.5 4' x 1'/2" 50.8 54.0 101.6 181.1 90.4 70.6 2.5 2.50 2.63 4.00 7.13 4.06 2.78 6.0 4'x 2' 63.5 66.7 101.6 181.1 103.1 70.6 2.7 2.75 2.88 4.00 7.13 4.38 2.78 6.0 4' x 21/2" 69.9 73.0 101.6 181.1 111.3 70.6 2.7 2.75 2.88 4.00 7.13 4.38 2.78 6.0 4' x 76.1 mm 69.9 73.0 101.6 181.1 111.3 70.6 2.7 3.50 3.63 4.13 7.13 5.13 2.78 7.0 4'x 3' 88.9 92.1 104.9 181.1 130.3 70.6 3.2 2.00 2.13 4.63 8.13 3.56 3.37 6.5 5'x 11/2" 50.8 1 54.0 1 117.6 206.5 1 90.4 1 85.6 12.91 I Figure 730 Mechanical Outlet Grooved Tee Nom. Size Hole Dia. t Dimensions Net Wt. HoleMax. A B C E Run x Branch Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm Kg. 2.50 2.63 4.63 8.13 4.06 3.37 7.1 5"x 2" 63.5 66.7 117.6 206.5 103.1 85.6 3.2 5" x 21/2' 2.75 2.88 4.75 8.13 4.38 3.37 7.3 69.9 73.0 120.7 206.5 111.3 85.61 3.3 2.75 2.88 4.75 8.13 4.38 3.37 7.3 5" x 76.1mm 69.9 73.0 120.7 206.5 111.3 85.6 3.3 3.50 3.63 5.00 8.13 5.13 3.37 7.6 5" x 3' 88.9 92.1 127.0 206.5 130.3 85.6 3.4 2.00 2.13 5.13 9.25 3.56 3.90 7.4 6' x 1'/2' 50.8 54.0 130.3 235.0 90.4 99.1 3.4 2.50 2.63 5.13 9.25 4.06 3.90 7.5 6"x 2' 50.8 66.7 130.3 235.0 103.1 99.1 3.4 2.75 2.88 5.13 9.25 4.38 3.90 7.5 6" x 2'/2' 69.9 73.0 130.3 235.0 111.3 99.1 3.4 2.75 2.88 5.13 9.25 4.38 3.90 7.5 6" x 76.1mm 1 69.9 73.0 130.3 235.0 111.3 99.1 3.4 3.50 3.63 5.50 9.25 5.13 3.90 9.5 6"x 3' 88.9 92.1 139.7 235.0 130.3 99.1 4.3 4.50 4.63 5.38 9.25 6.13 3.90 10.0 6" x 4' 114.3 117.5 136.7 235.0 155.7 99.1 1 4.5 2.75 2.88 6.25 12.50 4.38 4.90 10.2 8" x 21/2' 69.9 73.0 158.8 317.5 111.3 124.5 4.6 2.75 2.88 6.25 12.50 4.38 4.90 10.2 8"x 76.1 mm 69.9 73.0 158.8 317.5 111.3 124.5 4.6 3.50 3.63 6.50 12.50 5.13 4.90 12.5 8"x 3' 88.9 92.1 165.1 1 317.5 130.3 124.5 5.7 4.50 4.63 6.38 12.50 6.13 4.90 12.5 8"x 4' 114.3 117.5 162.1 317.5 155.7 124.5 5.7 t Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/e' of the hole to be certain it is free from conditions which would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, which might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. Note: Outlet threads conforming to BSP are available, contact Tyco Fire Products for details. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (I1-1-1000). Never remove any piping component nor correct or modify any piping deficiencies 15O without first depressurizing and draining the system. Material and gasket selection should be verified to be 9001 compatible for the specific application. Certified Company Flow Control Tyco Fire Printed in U.S.A. 4-01 �LiCO / Products Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 U IFM See Fire Protection • Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI B16.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over - tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make -on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/2" - 21/2" Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI 816.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) Ordering ri Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 1 Figure 811 90` Elbow Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. '/2 11/8 '116 86206 0.24 240 3/4 15/16 '/4 86205 0.40 120 1 1'/2 "/Is 86200 0.64 70 111, 13/< 17/16 86201 0.95 1 40 1'!2 115,',5 1'/16 86202 1.24 30 2 21/4 1'12 86203 1.74 20 2'/2 211/16 1'/16 86204 3.28 10 • r Figure 812 f 90° Reducing Elbow C ` A Size Inches A Inches B Inches C Inches D Part Inches Number Weight Lbs. Box Qty. 314 x 112 13/16 11116 5/8 5/8 86342 0.33 160 1 x '/2 1'/4 13/8 1/16 13116 86210 0.44 110 1 x'/4 1318 1'/+s "/is 'la 86211 0.53 90 1'A x'/2 15/18 11/2 3/s 5/,e 86212 0.64 75 1'/4 x'/4 1'/16 15/8 3/4 1'he 86213 0.75 60 1114 x 1 19/16 111/16 '/6 1 86214 0.77 55 1'/2 x'/. 11/2 13/4 3/4 1'/,e 86221 0.95 45 1'12 x 1 13/8 113/16 '/8 11/8 86215 0.99 1 "/16 1'/2 x 1'/4 11'/16 17/8 1'/s 13/ie 86216 1.14 2 x'/4 13/8 115/+6 'le 13/6 86217 1.39 L25 2 x 1 13/4 2'/16 2 Vbe 86218 1.58 1'/16 2 x 11/2 2 23/16 11/4 1'/+e 86220 1.67 2'/2 x 2 23/6 23/8 11/4 7/11 1 86262 r3.01 15 Figure 813 45' Elbow Figure 814 Tee Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. '/2 7/8 '/6 86780 0.22 250 3/4 1 '/16 86781 0.33 150 1 11/8 13/16 86280 1 0.48 90 1'/4 13!16 518 86281 0.73 50 1V2 1'116 1 "/16 86282 0.93 35 2 1 "/16 "/is 86283 1.55 18 2'/2 1 `/is 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 11/8 '/16 86340 0.33 150 3A 15/16 '/4 86341 0.50 90 1 1 V2 "/16 86230 0.85 60 1'/4 13A 1'/16 1 86231 1.30 35 1'/2 1'5/16 13/16 86232 1.63 24 2 2'/4 1'/2 86233 2.63 12 21/2 2"A6 19/+6 86234 4.55 8 a E , F Figure 815 - Reducing Tee II -- Size Inches A 8 C D E F Part Inches Inches Inches Inches Inches Inches Number Wt. Box Lbs. Qty. '/4 X'/4 x V2 1-,x•6 1'/16 1114 5/8 5/e "/1s 86235 0.46 95 3/4 x'/4 x ' ! 1 " = I 1 /.6 1'/8 6 Va I '1/-5 86755 0.68 65 1 x 1/2 x 1 1':2 i'/8 1'/2 13/15 "/ 6 6 86236 0.70 55 1 x 3/4 X 112 1. / 1'!16 1 1'/8 9/16 5/8 "/,6 86756 0.63 80 1 X 3/4 x 3/4 1 "s 15/16 1'/16 '1/,6 3/4 '/s 86757 0.68 65 1 x 3/d x 1 1 !2 1'/16 11/2 "/16 '/8 "/,6 86237 0.77 55 1 x 1 x'/2 1';. 1'/d 1'/8 '/16 '116 "/,6 86238 0.66 65 1 x 1 x'/4 11/8 13/8 1'/16 "/1s "/16 '/e 86239 0.73 60 1 x 1 x 11/4 111/16 1 "/16 19/18 1 1 '/e 86240 0.97 45 1 x 1 x 11/2 1 "116 1 "/16 15/8 1'/6 1'!e '/B 86241 1.14 35 I 1 X 1 X'12 '; "/16 VA 19/18 5/8 '/1s 1 86242 0.81 50 11/4 X 1 X 3/4 1'/16 13/8 15/8 3/4 "/1s 1'/16 86243 0.901 50 11/4 x 1 x 1 19116 1'/z 1 "/16 '/8 "116 1 86244 1.03 45 11/4 x 1 x 11/4 13/4 111/16 13/4 1'/16 1 1'/16 86245 1.10 40 1'/4 x 1 x 1'12 11/6 113/16 113/19 13/+8 1'/8 1'/1s 86246 1.43 30 11/4 x 11/4 x 1/2 1116 13/8 19/+6 11/18 11/16 1 86247 0.87 45 1'/4x1'/4x3/4 11/16 1'/16 15/s 3/4 3/4 11/16 86248 0.96 45 11/4 x 11/4 X 1 19/16 1'/16 111/16 '/8 '/s 1 86249 1.101 40 11/4 X 1'/4 X 11/ 1116 11/8 1131+6 111/16 113/16 1'/1s 86250 1.501 30 11/4 x VA x 2 2'/6 2'/a 2 11/16 171+8 1'/8 86251 2.001 24 1'/2 X 1 X V2 1'/16 15/18 1 "/16 1'/16 5/8 1'/e 86252 0.97 40 1'/2 x 1 x 3/4 1'/2 13/8 13/4 3/4 11/16 13/16 86253 1.14 40 11/2 x 1 x 1 15/8 11/2 113/16 '/8 13/16 VA 86254 1.14 30 11/2 x 1 x 1'/2 1 t5116 113/16 1 X5/16 13/16 11/8 13/16 86255 1.52 30 11/2 x 1114 x7/2 1'/16 13/16 11'/16 "/16 5/e 1 1'/8 86257 1.03 40 V/2 x 174 04 1'/2 1'/16 13/4 3/4 3/. 1 1'/le 86258 1.10 40 1'/2 x 1'!4 x 1 15/8 19/16 1 "/16 '/8 '/a 1'/8 86259 1.31 30 1'/2 x 1114 x2 2'116 21/8 2 1'/+s 1'/+s 1'/4 86260 1.94 20 11/2 x 1'/2x'/2 1'/16 1'h6 1 "/16 "/16 "/le 1 /s 86261 1.14 35 11/2x1'/2x3/4 1'/2 11/2 13/4 'A 3/4 13/+6 86262 1.23 35 1'12 x 1'12 x 1 13/8 13/8 113/16 '/8 '/e 1'/8 86263 1.381 30 11/2 X 11/2 X 11/ 113/16 113/ 16 1'/8 1 V16 17/18 1 13/16 86264 1.501 30 1'/2x1'/2x2 2'/16 23/16 2 1'/16 1'/16 1'/4 86265 2.00 20 2 x 1 x 2 2'/. 2 2'/4 1'/2 13/1s 1'/2 86266 2.18 15 2x1'/4x2 2'/, 2'/e 2'/4 1'/2 17/16 1'!z 86267 2.31 15 2 x 1'/2 X 11 1'!z 1'/16 1'/e 3/4 "hs 15116 86268 1.50 30 2x 1'/2x 3/4 15/a 11/2 115/16 1/8 3/4 1 /8 86269 1.61 25 2 x 11/2 x 1 13/. 15/8 2 1 '/B 15/16 186270 1.65 20 2'/16 1'3/16 2'/1s 15/16 13/16 1'/+6 86272 2.03 20 2'/4 2'/16 21/4 11/2 1'/16 1'/2 86273 2.37 15 rx2 1'I2 11/2 1'/83/4 3/4 15/16 86222 1.50 30 15la 15/8 115/16 7/8 '/8 1'/B 86223 1.67 20 13/. 1'/d 2 1 1 15/,s 66224 1.91 20 2 x 2 x 1'/4 17/8 17/8 21/B 11/8 11/8 17116 86225 2.05 20 2 x 2 x 11/2 2 2 23/16 VA 1'/4 11/2 86226 2.11 15 2 x 2 x 2'/2 25/8 23/8 23/8 13/6 17/8 17/16 86227 3.67 10 21/2 x 2 X 3/4 13/4 15/8 25/16 5/a '/a 13/4 86274 2.221 15 -2- Figure 816 Reducing Coupling BE vi Size Inches A Inches 8 Part Weight Box Inches Number Lbs. Qty. 3/4 x'/2 13/4 1'h6 86772 0.38 240 1 x '/2 1 "hs '/2 86228 0.38 200 1 x'/. 1314 '/2 86229 0.53 110 A^t--A - i D Figure 817 c Cross -c D B Size inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 1 1'/2 11/2 13/16 13/16 86284 0.97 45 72778 13 /4 1'/4 1'116 1 V16 86285 1.59 25 1'/2 115/16 115/18 13/16 13/16 86286 1.89 20 2 2'/4 21/4 1 11/2 1'/2 86287 2.93 10 1'/. x 1114 x 1 x 1 1"/ta 1 1/16 1 '/a 86289 1.25 30 V12 1'12x 1 x 1 1'3/1e 15/8 1'/16 1i5/16 86322 1.48 24 2 x 2 x 1 x 1 2 13/4 1'14 1'/1e 86291 2.64 10 Figure 818 B A Straight Coupling Size Inches A I Inches B Inches Part Number Wrench Weight Lbs. Box Oty. '/2 13/8 8/16 72779 1'/a 0.18 360 3/4 15/8 '/is 72778 13/a 0.26 200 1 1314 3/e 72755 1' /1s 0.44 110 11/4 2 '/1s 72754 2 0.54 75 1'/2 23/16 3A 72753 2V4 0.71 60 2 2% 1'/8 72752 2 3 A 1.15 30 2'/2 3 3A 72758 33/a 2.29 18 Figure 820 Cap Size Inches A Part Inches Number Weight Lbs. Box Qty. V2 '/s 72776 0.15 500 3/4 1 72777 0.22 300 1 13/16 72824 0.33 180 1 V4 15/16 72756 0.54 110 1'12 13/8 72822 0.68 80 2 1'/2 72823 0.96 45 2'/2 13/4 72825 1.80 25 -3- Figure 825 Extension Piece Figure 827 Hex Bushing Size Inches A iiPart Inches Number Weight Lbs. 1 Box Oty. '/2 x 11/2 1'/2 72751 0.20 300 '/2 x 2 2 72980 0.27 250 '/4 x 1'/2 11/2 72981 0.22 250 F77x-2 2 2 72982 0.31 200 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1 x'/2 1'/16 72726 0.22 280 1 x 3/. 1'116 72762 0.18 280 1'/4 x 1 13/16 72763 0.31 150 1'/2 x 1 VA 72757 0.53 100 1'/2x1'/. 11/. 72764 0.35 100 2 x 1 1 /s 72759 0.75 80 2 x 1'/4 13/s 72761 0.69 80 2 x 1'/2 13/a 72775 0.62 80 Figure 830A Brass Seat Union I- - -" Size Inches A Inches 8 Inches Part Number Weight Lbs. Box Qty. 1/2 1Ve 17/16 86207 0.47 110 '/4 2 15/16 86275 0.66 80 1 23/16 13/te 86276 1.08 50 11/4 11/2 17/16 86277 1.54 35 1'/z 1'/z =T/al'/s 86278 2.03 25 2 86279 3.15 18 Figure 719 Cast Iron Plug Size Inches A Inches Part Number Weight Lbs. Box Qty. '/2 15/16 86292 0.10 500 3/4 1'/e 86293 0.18 300 1 1'/4 86294' 0.28 200 1 V4 13/s 86295 0.50 110 11/2 17/16 86296 0.70 80 2 1'/z 86297 0.90 45 Street Elbows Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Qty. 1 x `L 1'h 'ls 3 42003 0.70 80 1 x 1 1'/z '/a 3 42002 0.90 60 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or Fir= I I e I California Tees c c � I Size Inches A Inches B Inches C D Part Inches Inches Number Weight lbs. Box Qty. 1 x '/z x 1 1'/a '/a 3 '/a 42000 0.95 50 1 x 1 x 1 1'/: 314 3 '/< 42001 0.95 45 which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. SHE FOREGOING WARRANTY IS N LIEU OF ANY AND ALLOW WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE, General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. tgCO/Flow Control/ Tyco Fire Products -4- Printed U.S.A. 10-01 w DynamThread a Full Line Sch-40 Replacement Dyna -Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna -Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. 7, Comparison to Schedule 40'��"'�i • Dyna -Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna -Flow pipe down sizing often occurs. • Dyna -Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. • The life expectancy of Dyna -Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. • The consistent quality of steel used to make Dyna -Thread facilitates smooth threading and lower maintenance costs. • The exterior of Dyna -Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. U� FM USC Listed Approved Listed • With its increased strength and lighter weight, Dyna -Thread reduces installation fatigue and is ideal for retro -fit applications. • More wall thickness at the thread (CRR=1.00) gives Dyna -Thread better life expectancy than lightwall threadable pipe joints. Corrosion Resistance Ratio (CRR) is a • Unlike lightwall threadable pipe, UL (Underwriters Laboratory) term for Dyna -Thread has no thread gauge the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna - Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. warning. • Dyna -Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna -Thread is safer to weld on. • Dyna -Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre -action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot -dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll -grooved, and plain -end fittings. (See listing information). 16100 S. Lathrop • Harvey, IL 60426 Customer Service: rtZ�CtD/F/ow Control P allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3-3 ecifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WVLift (21') Wl/Lift (24') Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1'/e' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 1'/i 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 warning. • Dyna -Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna -Thread is safer to weld on. • Dyna -Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre -action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot -dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll -grooved, and plain -end fittings. (See listing information). 16100 S. Lathrop • Harvey, IL 60426 Customer Service: rtZ�CtD/F/ow Control P allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3-3