HomeMy WebLinkAbout604 Grovewood Avet'
CITY OF SANFORD PERMIT APPLICATION
Permit #
Job Address:
Description of Work:
Historic District:
Date: I' V G1 V S lJ , 2 U O
Permit Type: Building _k__ Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool
Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial
Occupancy Type: Residential D Commercial Industrial Total Square Footage:
Construction Type: e_ of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X)
Contractor Name & Address:
Phone & Fax:
Contact
State License Number:
Z
Bonding Company: '
Address: UL 0. h1mr—i 011
Mortgage Lender:
Address: '
Architect/Engineer: + '{ -ohliwj
Address: Fax:
Application is hereby made to obtain a permit to do the work and installations as indicated; I.ce t at o rk r n Ilat n cortsmegced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating c n ' i j s n 1 understaiid;tlrat a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS;,POOLS, FU R S, TANKS'; and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of pefmit is verification that I will noti5 the owns •of�the property of the requirements of Florida Lien Law, FS 713.
&J0 5
�,+. '• •Nor �lgnatweOwner/Agent Date Signature of Contractor/Agent Date
igo: 1.Ta-
',►coq:'
Print Ow e
a Mn>0
X o
$ (�
3 �• �, Signature of Notary -State of Flo4da
Date
w 0 y y. y•
a � CV
m N Owner/Agent is_ Pe n II Known to Me or
0 2 N a ,produced ID T� Z4 32b 96yO
v6iwrri'•
�(
APPLICATION APPROVED BY: Bldg
Z-V-lZoning:
'"'
(Initial &Date)
Print Contractor/Agent's Name
Signature of Notary -State of Florida Date
Contractor/Agent is _ Personally Known to Me or
Produced ID
(Initial & Date)
Utilities: FD:
(Initial & Date) (Initial & Date)
Special Conditions:
�q,o0
CITY OF SANFORD BUILDING -DIVISION
OWNER/BUILDER AFFIDAVIT
CONSTRUCTION CONTRACTING
Owners of property when acting as their own contractor and providing direct, onsite supervision
themselves of all work not performed by licensed contractors, when building or improving farcn
outbuildings or one -family or two-family residences on such property for the occupancy or use of such
owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to
exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or
lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such
structure by the owner -builder within 1 year after completion of same creates a presumption that the
construction was undertaken for purposes of sale or lease. This subsection does not exempt any person
who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The
owner may not delegate the owner's responsibility to directly supervise all work to any other person
unless that person is registered or certified under this part and the work being performed is within the
scope of that person's license. For the purposes of this subsection, the term "owners of property"
includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this
subsection, an owner must personally appear and sign the building permit application.
State law requires construction to be done by licensed contractors. You have applied for a permit under
an exemption to that law. The exemption allows you, as the owner of your property, to act as your awn
contractor with certain restrictions even though you do not have a license. You must provide direct,
onsite supervision of the construction yourself. You may build or improve a one -family or two-family
residence or a farm outbuilding. You may also build or improve a commercial building, provided your
costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may
not be built or substantially improved for sale or lease. If you sell or lease a building you have built or
substantially improved yourself within 1 year after the construction is complete, the law will presurr;.e that.
you built or substantially improved it for sale or lease, which is a violation of this exemption. You n,a.y
not hire an unlicensed person to act as your contractor or to supervise people working on your It
is your responsibility to make sure that people employed by you have licenses required by state law iiad.
by county or municipal licensing ordinances. You may not delegate the responsibility for supervising
work to a licensed contractor who is not licensed to perform the work being done. Any person working
on your building who is not licensed must work under your direct supervision and must be employed by
you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation
for that employee, all as prescribed by law. Your construction must comply with all applicable laws,
ordinances, building codes, and zoning regulations.
I, , do hereby state that I am qualified and capable of performing the
requested construction involved with the permit application filed.
I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work
allowed by law on the permitted structure.
caner/Builder Signature Date
=�•
Print Owner/Builder Name
IS� g
3.
Si�,nauirc of Notary—Blatt of 1=lorida Uate
p N�
Owner is Personally hnoven l0 :.xle or has
Produced II) .- .� Lf3
r
OFFICE COPY
AAMA/NWWDA 101/I.S.2-97
TEST REPORT SUMMARY
Rendered to:
NII HOME PRODUCTS, INC.
PPR bY h.Qlo
PIANS REVIEWED
CITY OF SANFORD
SERIES/MODEL: 740/744
TYPE: Aluminum Single Hung Window with Flange
Title of Test
Results
Rating
H -R45 53 x 73
Overall Design Pressure
45 psf
Operating Force
23 lbs max.
Air Infiltration
0.10 cfm/
Water Resistance
6.75 psf
Structural Test Pressure
+67.5 psf
-70.8 psf
Deglazing
Passed
Forced En Resistance
Grade 10
Reference should be made to Report No. 01-40351.04 for complete test specimen description and
data.
For ARCHITECTURAL TESTING, INC.
Mark A. Hess, Technician -~
F
NATIONAL CERTIFIED TESTING LABORATORIES
1464 GEMINI BOULEVARD • ORLANDO, FLORIDA 32837
PHONE (407) 240-1356 • FAX (407) 240-8882
IN -PLANT WITNESS
STRUCTURAL PERFORMANCE TEST REPORT
Report No. NCTL-310-0005-5.1
Test Date:
07115198
Report Date:
08103198
Expiration Date:
07130102
Revision Date:
09129198
Client: Metal Industries Home Products
650 West. Market Street
Gratz, PA 17030
Test Specimen: Betterbilt, Inc.'s Series 'BB165/7401744"Fired Lite Aluminum Prime Window
(F-050 72 x 72). This unit was flange mounted and is "valid for tempered glass only."
Test Specification: AAMA/NWWDA 1011I.S.2-97, "Voluntary Specifications for Aluminum, Vinyl
(PVC), and Wood Windows and Glass Doors."
Test Site: Betterbilt, Smyrna, TN, all calibrations were
. performed before testing.
TEST SPECIMEN DESCRIPTION
General: The test specimen was an aluminum prime window measuring 72-1 /4" wide by 72-114"
high overall. The fixed lite was glazed to the frame members, providing a viewing area of 69-118m
wide by 69-1 /8" high. The frame was of double screw (#8x5/8) butt -type corner construction. From
the interior view the left corners were sealed with small joint sealant and the right corners employed
gasket tape.
Glazing: The lite was interior glazed using 8116" clear tempered glass with a butyl tape back.
bedding, a vinyl bulb gasket, and an extruded aluminum glazing bead. The glazing bead was
fastened with #8.x7/8 screws every 8".
Weatherseals: No weatherseals employed.
Weeps: No apparent weeps employed.
Interior & Exterior Surface Finish: Mill finished aluminum. .
Sealant: The l h,l .'
eft frame corners were sealed with a small joint sealant and the � t4�me•co
employed gasket tape. :' ,• � _�'• . �-
. rw
6A..
4 `J
: ^.
PROFESSIONALS IN THE SCIENCE OF TESTINGSO
:rti
C.
Metal Industries Home Products
For. No. Title of Test & Method
2.1.2
2.1.3
2.1.4.2
2.1.8
4.3
4.4.2
-2- NCTL-310-OOO5-5.1
TEST RESULTS
Measured Allowed
Air Infiltration - ASTM E283
1.57 psf (25 mph) Pass
Water Resistance - ASTME547
5.0 GPH/FT'
wTP= 3 00 psf No Leakage
Uniform Load Structural - ASTM E330
30.0 psf Exterior 0.000"
30.0 psf Interior 0.000"
` Forced Entry Resistance
(see Appendix A for results)
OPTIONAL PERFORMANCE
Pass / Fail
No Leakage
0.285"
0.285"
f�Tl? qM, :_A
Water Resistance - ASTM E547
5.0 GPH/FT'
wTP= 7.50 psf No leakage No Leakage
Uniform Load Structural - ASTME330
75.0 psf Exterior 0.000" 0.285"
75.0 psf Interior 0.000" 0.285"
No glass breakage or permanent damage causing the unit to be inoperable
TEST COMPLETED 07/15/98
The tested specimen meets (or exceeds) the performance leaels specified in Table 2.1 of
AAMA/NWWDA 1011I S.2-97 for air infiltration. The listed results were secured by using the
designated test methods and indicate compliance with the performance requirements of the referenced
specification paragraphs for the F-050 72x72 product designation.
�•.,.
^ ;v hrr
BN:�
...
•
Metal Industries Some Products -3
NCTL-310-0005-5.1
Detailed drawings were available for laboratory records and compared to the test specimen at the
time of this report. A copy of this report along with representative sections of the test specimen will be
retained by NCTL for a period of four (4) years. The results obtained apply only to the specimen
tested No conclusions of any kind regarding the adequacy or inadequacy of the glass in the test
specimen may be drawn from this test. 79ais report does not constitute certification of the product
which may only be granted by a certification program validator.
NA77ONAL CER77=D TESTING LABORATORIES
Wayne Breighner
Manager, Great Lakes
^ Barry Pbrtnoy, P.E.
5767 Major Boulevard
Orlando, FL 32819
n WB/amb
Ref NCTL-310-0005-5.1
1
Metal Industries Home Products
_4-
NCTL-310-0005-5.1
APPENDIX A
Forced Entry Resistance Test Results
Test Method: ASTM F588 97, `Standard Test Methods For Measuring the Forced Entry Resistance
of Window;Assemblies, Excluding Glazing Impact."
Test Results
Paragraph No. Loads Duration Measured Allowed
10.2.4.2 N/A 5 Minutes No Entry No Entry
. ``» may.►+' e• � .. • ''r.
}
4
MI HOME PRODUCTS
- PRIME ALUMINUM WINDOWS -
-- INSTALLATION INSTRUCTIONS FOR
"NAIL FIN" PRODUCTS
MI Home Products appreciates your recent purchase of a maintenance free prime window, which will not
rust, rot, mildew, or warp. • This is a quality product that left our factory In good condition — proper handling
and installation are. just as important as good design and workmanship. ' Please follow these
recommendations to allow this product to complete its function.
1. Handle units one at a time in the closed and loc�ed position and take care not to scratch frame or glass
or to bend the nailing fin.
2. Set unit plumb and square into opening and make sure that there is 3/16" + 1/16" clearance around the
frame. Fasten unit into opening in the closed and locked position, making sure that fasteners are
screwed in straight in order to avoid twisting or bowing of the frame. Make sure that sill is straight and
level. Check operation of unit before any and all fasteners are set.
3. Use # 8 sheet metal or wood screws with a minimum of 1' penetration into the framing (stud). Place first
screws (two at each comer) 3" from end of fin. For positive and negative DPs (design pressures) up to
35, do not exceed 24" spacing of additional screws. For DPs from 35.1 to 50, do not exceed 18". Install
load bearing shim adjacent to each anchor. Use shim where space exceeds 1/16'.
4. Flash over head and caulk outside perimeter in accordance with code requirements and good installation
practices.
5. Fill voids between frame and construction with loose batten type insulation or non -expanding aerosol
foam specifically formulated for windows and doors to eliminate drafts. The use of expanding aerosol
type insulating foam, which can bow the frame, waives all stated warranties.
6. Remove plaster, mortar, paint and any other debris that may have collected on the unit and make sure
that sash/vent tracks and interlocks are also clear. Do not use abrasives, solvents, ammonia, vinegar,
alkaline, or acid solutions for clean-up, especially with insulated glass units as their use could cause
chemical breakdown of the glass seal. Take care not to scratch glass; scratches severely weaken glass
and it could eventually break from thenal expansion and contraction. Clean units with water and mild
detergent as you would you automobile.
- CAUTION -
MI Home 'Products or its representatives are unable to control and cannot assume responsibility for the
selection and placement of their products in a building or structure in a manner required by laws, statutes,
and/or building codes. The purchaser is solely responsible for knowledge of and adherence to the same. MI
Home Products window products are not provided with safety glazing unless specifically ordered with such.
Many laws and codes require safety glazing near doors, bathtubs, and shower enclosures. Also be aware of
emergency egress code requirements.
Corporate Headquarters:
650 West Market St. CENTRAL FLOR .A B.O.A F. .�• . -,,
�
Gratz, PA 17030-0370` A NAS;
• � ��� c " .-' ,�
36 -
(717 5-3300 �E77�h' a I LT / M/ &.AJ4
MATER LTi ,��a� , �r ► •�. ".
_ •% 'ti-
L
DOCUMENT CONTROL ADDENDUM #0140486.00
Current Issue Date: 02/15/02
Report No.: 0140486.01
Requested by: William Emley, MI Home Products, Inc.
Purpose: A 101/I.S.2-97 testing of Series/Model 744, aluminum
picture window with vertical mullion.
Issued Date: 01/02/02
Comments: Florida P.E. seal required on report.
Report No.: 0140486.02
Requested by: William Emley, MI Home Products, Inc.
Purpose: AAMAJNWWDA 101/I.S.2-97 testing of Series/Model 740/744, aluminum
picture window with vertical mullion, and installation fasteners through
frame.
Issued Date: 02/15/02
Comments: Florida P.E. seal required on all pages of report. Certification copy to John
Smith at Associated Laboratories, Inc.
L
i
Architectural Testing
AAMA/NWWDA 101/l.S.2-97 TEST REPORT
Rendered to:
NII HOME PRODUCTS, INC.
P.O. Box 370
Gratz, Pennsylvania 17030-0370
ReportNo: 01-40351.04
Test Date: 10/22/01
And: 10/23/01
Report Date: 02/14/02
Expiration Date: 10/23/05
Project Summary: Architectural Testing, Inc. (ATI) was contracted by MI Home Products, Inc.
to witness performance testing on a Series/Model 740/744, aluminum single hung window at MI
Home Products, Inc. s test facility in Elizabethville, Pennsylvania. The sample tested
successfully met the performance requirements for an H -R45 53 x 73 rating.
Test Specification: The test specimen was evaluated in accordance with A
101/I.S.2-97, Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass
Doors. P.
Test Specimen Description:
Series/Model: 740/744
Type: Aluminum Single Hung Window With Flange
Overall Size: 4'4-7/8" wide by 60-1/8" high
Active Sash Size: 4'2-3/4" wide by 2' 11-3/4" high
Fixed Daylight Opening Size: 4'1-1/8" wide by 2'9" high
Screen Size: 4'1-7/8" wide by TI 1-5/16" high
Finish: All aluminum was polished.
Glazing Details: The active sash and fixed lite were glazed with one sheet of 1/8" thick
clear, tempered glass. Each sash was channel glazed using a flexible vinyl gasket.
130 Derry Court
York, PA 17402-9405
phone: 717.764.7700
fax: 717.764.4129
www.testati.com
/S XXArorVq Iy 2oo z
EN
01-40351.04
Page 2 of 4
Test Specimen Description: (Continued)
Weatherstripping:
Description Quantit * Location
0.330" high by 0.187' 1 Row Fixed meeting rail interlock
backed polypile
with center fin
0.170" high by 0.187' 1 Row Fixed lite, stiles and top rail
backed polypile
with center fin
3/8" diameter hollow 1 Row Bottom rail
bulb gasket
0.310" high by 0.187' 1 Row Active sash stiles
backed polypile
with center fin
0.150" high by 0.187' 1 Row Active sash stiles
wide polypile
Frame Construction: All frame members were constructed of extruded aluminum with
coped, butted and sealed comers fastened with. two screws each. Fixed meeting rail was
secured utilizing one screw in each end directly through exterior face into jamb. Silicone
was utilized around exterior meeting rai)ramb joinery.
Sash Construction: All sash members were constructed of extruded aluminum with coped
and butted comers fastened with one screw each.
Screen Construction: The screen frame was constructed from roll formed aluminum
members with plastic keyed comers. The screening consisted of a fiberglass mesh and was
secured with a flexible vinyl spline.
Hardware:
Description
Plastic tilt latch
Metal sweep lock
Balance assembly
Screen tension spring
Tilt pin
n
uanti Location
2 One each end of the interior
meeting rail
2 13" from meeting rail ends
2 One per jamb
2 One per end of screen stile
2 One each end of bottom
/.S' Fed4RvI4.4 206 '
Test Specimen Description:
Drainage: Sloped sill
Reinforcement: No reinforcement was utilized.
0140351.04
Page 3 of 4
Installation: The test buck was fabricated from 2 x 8 #2 Spruce -Pine -Fir. The unit was
secured utilizing three 1-5/8" drywall screws through the jamb track, 5" from sill, 1-3/4"
below meeting rail and 1" from head. The head utilized drywall screws 3-1/2" from jambs
and midspan. Exterior perimeter was sealed with silicone.
Test Results:
The results are tabulated as follows:
Par g nh
Title of Test - Test Method Results
Allowed
2.2.1.6.1
Operating Force 23 lbs
30 lbs max,
2.1.2
Air Infiltration per ASTM E 283 (See Note #1)
Q 1.57 psf (25 mph) 0.10 cf n/i
0.30 cfin/fl max.
Note #l:
The tested specimen meets (or exceeds) the performance levels specified in
AAMAINWWDA 101/1 & 2-97for air infiltration.
2.1.3.
Water Resistance per ASTM E 547-96
(with and without screen)
WTP = 2.86 psf See Note #2
No leakage
Note #2:
The client opted to start at a pressure higher than the minimum required Those
results are listed under "Optional Performance".
2.1.4.2
Uniform Load Structural per ASTM E 330-97
(Measurements were taken on the meeting rail)
Ga 22.5 psf (positive)
0.20" max.
22.5 psf (negative) See Note #2
0.20" max.
2.2.1.6.2
Deglazing Test per ASTM E 987
In operating direction at 70 lbs
Top rail
Bottom rail
In remaining direction at 50 lbs
0.06"/12% 0.50"/100%
0.06"/12% 0.50"/100%
Left stile 0.03"/6% 0.50"/100%
Right stile 0.03"/6% 0.50"/100%. .
i
' 01-00351.04
Page 4 of 4
Test Results: (Continued)
Paragraph Title of Test - Test Method
Results
Allowed
2.1.8 Forced Entry Resistance per ASTM F 588-97
Type: A
Grade: 10
Lock Manipulation Test
No entry
No entry
Test A 1 thm A5
No entry
No entry
Test A7
No entry
No entry
Lock Manipulation Test
No entry
No entry
OQtional Performance
4.3 Water Resistance per ASTM E 547-96
((with and without screen)
WTP = 6.75 psf No leakage No leakage
4.4.1 Uniform Load Deflection per ASTM E 330-97
(Measurements were taken on the meeting rail)
(Loads held for 52 seconds)
45.0 psf (positive) 0.95* 0.29" max.
45.0 psf (negative) 0.79* 0.29" max.
* Exceeds L/I75 for deflection, but meets all other test requirements
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements were taken on the meeting rail)
(Loads held for 10 seconds)
g67.5 psf (positive) 0.14" 0.20" max.
a 67.5 psf (negative) 0.16" 0.20" max.
4.4.2 @ 70.8 psf (negative) 0.19" 0.20" max.
Detailed drawin s, representative samples of the test specimen, and a copy of this report.will be
retained by ATI for a period of four years. The above results were secured by using the
designated test methods and they indicate compliance with the performance requirements of the
above referenced specification. This report does not constitute certification of this product which
may only be granted by the certification program administrator.
For ARCHITECTURAL TESTING, INC:
-�F� "�- /'Z"
Mark A. Hess
Technician
MM:baw
01-40351.04
Allen N. Reeves, P.E. - -
Director — Engineering Services r
740/744 SH & PW SERIES - MILE PER HOUR (MPH) MAXIMUM SIZE CHART
r All Transoms (•1, 2, & 3-Lites) must be continuous frame.
n Trar units must be a minimum of 110 tall. The maximum transom height is one half the width of the transom.
Both E ; Hung & Picture Windows can be used in combination up to the maximi • izes listed above.
Rev 7-16-02
MAXIMUM SIZES ALLOWED
SERIESITYPE
MPH ZONE(S)
REQUIRED MULLION
SINGLE UNIT
TWIN UNIT
TRIPLE UNIT
7401744 SH OR PW
FIN OR FLANGE FRAME
UP TO 140 MPH
NIA
N/A
63-11&'X 72-114"
NIA
NIA
SNG GLZOR INS
7401744 SH OR PW
VERTICAL
..:,
FIN FRAME
UP TO 130 MPH
MULL
NIA
63-118" X 72-114"
63-118" X 72.114"
SNG GLZOR INS
#V43-
7401744 SH OR PW
VERTICAL
63-1/8" X 63"
53-118" X 63"
FIN FRAMC
UP TO 140 MPH
MULL
y <: t« <. •...;
N/A
OR
OR
SNG GLZOR INS
42" X 72-114"
42" X 72-114"
7401744 SH OR PW
VERTICAL
FLANGE FRAME
UP TO 130 MPH
MULL
?. %,�•:::.a
NIA
53-1/8" x 72-1/4"
63-118" X 72-114"
SNG GLZOR INS
#V83
7401744 SH OR PW
UP TO 140 MPH
VERTICAL
MULL>..,..;
; .. y,.,:
NIA
53-118" X 63"
63-118" X 63"
FLANGE FRAME
OR
OR
SNG GLZOR INS
#V83
42" X 72-1/4"
42" X 72-1/4"
7401744 SH OR PW
HORIZONTAL
FIN OR FLANGE FRAME
UP TO 120 MPH
MULL
-
N/A
53-1/2" X 72-114"
32" X 72-114"
SNG GLZOR INS
#H431H83
7401744 SH OR PW
HORIZONTAL
:..,.,
FIN on FLANGE FRAME
UP TO 140 MPH
MULL
"'''' •
:":
NIA
45" X 72-114"
30" X 72-114"
SNG GLZOR INS
#H431H83
?:-•:
W/TRANSOM*
W/TRANSOM*
7401744 SH OR PW
SELF-
FIN FRAME
UP TO 120 MPH
STACKING
is <' '
53-118" X 72-114"
NIA
NIA
SNG GLZOR (NS
SILL
: }...::
-.. ...
WITRANSOM *
7401744 SH OR PW
SELF-
,
FIN FRAME
UP TO 140 MPH
STACKING.
} :
48" X 72-114"
NIA
NIA
SNG GLZOR INS
SILL
WIPRANSOM*
7401744 SH OR PW
MULL #V83
' '
FLANGE FRAME
UP T0140 MPH
(USED
"
53-118" x 72-114"
NIA
N/A
SNG GLZOR INS
HORRONrALLY)
W/TRANSOM
r All Transoms (•1, 2, & 3-Lites) must be continuous frame.
n Trar units must be a minimum of 110 tall. The maximum transom height is one half the width of the transom.
Both E ; Hung & Picture Windows can be used in combination up to the maximi • izes listed above.
Rev 7-16-02
Concrete or Masonry Opening
v w
v %
v
i 2!
I Z •O � V p
L c a.
Perimeter Caulk, By Others
Also between flange and buck y
Head �m
41
I FlangeType
window Head
Topcon
Caulk Between Buck
and Masonry opening
By Others
Wood Buck by Others
€ I
CC
oGIwIQ w
a 5
e p
Class as Required e
c
Flonge Type
Wlndaw Frame SRI
Perimeter Caulk Sill
By Others
a Stool By Others
Pre—Cast 501 —/ .v a v a V a E
By Others
Caulk Between Flange and Pre—Coat 5111 C
Z. Anchor must be of sufficient length to provide 1 1/4" min. embedment'
Into masonry or concrete.
3. CauIK between window flange and buck.
4. Caulk full perimeter of window.
5. If exact window size is not given, use anchor quantity for
next larger window in chart.
6. Glass thickness will vary with window size and design load, and must comfy
with ASTM E1300.
7. letter designations on the tapcon location chart indicate where
anchors are to be Installed using the -elevation as a key.
8. All factory applied hales not designated for tapcon* should be filled with
#8 screws of sufficient ith, to provide 5/8" min. embedment into wood buck.
TAPCON * LOCATION CHART
�wlO� y opening SIS
OZE MANOW 10 FASTENER LOCATIONS
Concrete ar Masan+ 0P36 TO OP32 OP52.1 TO OP70A
Outside Oknenalon 1!' MIN. C
PENETRATION 12 18 1/8 x TS A C
Perimeter Caulk 13 18 1/8 x 37 3/8 A. C
14 18 1/8 x 49 5/8 A, C ti �
Caulk Between
15 18 1/8 x 62 A. C A, B, C
Flange and Buck 1 16 18 1/8 x 71 1/4 A, C A. S. C
\ •' a v: d
1/2 32 25 1/2 x 25 A. C A, C
1/2 33 25 1/2 x 37 3/8 A, C A C
1/2 34 125 1/2 x 49 5/8 A. C A. 8, C
1/2 351 25 1/2 x 52 A, B, C A. B. C
a d 1/2 36 25 1/2 x 71 1/4 A, B, C A, B. C
A•
Jamb 22 a v 23 36 6 37 38/ A 36 It 2 C A. C
24 36 x 49 5 C A B, C
G 245 36 x 55 1/8 4 ti e' � A. B, C
a A 25 36 x 62 A. B. C
A. ae.c
v 26 36 x 71 1/4 A, 8, C A. B. C. 0
"a'32 52 1/8 x 25 A. C A. C
A SHIM „ 33 52 1/8 x 37 3/8 A. C AN B, C
BUCK 4 ' °. a 34 52 1/8 x 49 5/8 A. 8, C A, 8, C
345 52 1/8 x 55 1/4 A, 8, C A. B. C. 0
35 52 1/8 x 62 A. B. C A. B. C. 0
Tapcon 36 52 1/8 x 71 1/4 A. B. C. 0 A. B. C, 0, E
Inside Dimension Woad Buck By Others
0 0
Caulk Between
Buck and Opening *'TAPCON' TYPE HARDENED MASONRY SCREWS
��' INCLUDE TAPCON, RAW, k SIMPSON
GYMBAL `WSMA IL 0.461. Design Pressure values listed above are In PSF
A 1L/itlRliACI' .K� as
E •'
? Y t 1.4;
;;� � t1o. •Ir.:x
C
EXTERIOR ELEVATION 77
lam INSTALLATION INSTRUCTIONS
& FASTENER SCHEDULE
740/744 SINGLE HUNG
Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1
I
PARCEL DETAIL
1Itlt k. f11-0 Vit.cop
Alt.. sr*3
O
x
2003 WORKING VALUE SUMMARY
Value Method: Market
GENERAL
Number of Buildings: 1
Parcel Id: 10-20-30-505-0000-0120 Tax District: S1-SANFORD
Depreciated Bldg Value: $76,288
Owner: FISHER FRANCES Exemptions:
Depreciated EXFT Value: $0
Address: 604 GROVEWOOD AVE
Land Value (Market): $14,000
City,State,ZipCode: SANFORD FL 32773
Land Value Ag: $0
Property Address: 604 GROVEWOOD AVE SANFORD 32773
Just/Market Value: $90,288
Subdivision Name: GROVEVIEW VILLAGE 1 ST ADD REPLAT
Assessed Value (SOH): $90,288
Dor: 01 -SINGLE FAMILY
Exempt Value: $0
Taxable Value: $90,288
2003 Notice of Proposed Property Tax
SALES
Deed Date Book Page Amount Vac/Imp
CORRECTIVE DEED 05/2002 04409 1470 $100 Improved
2002 VALUE SUMMARY
WARRANTY DEED 10/2001 04235 0436 $110,000 Improved
2002 Tax Bill Amount: $1,274
WARRANTY DEED 12/1999 03771 1525 $90,000 Improved
2002 Taxable Value: $60,199
WARRANTY DEED 09/1983 01488 1346 $58,400 Improved
Find Comparable Sales within this Subdivision
LAND
LEGAL DESCRIPTION PLAT
Land Assess Method Frontage Depth Land Units Unit Price Land Value
LEG LOT 12 GROVEVIEW VILLAGE 1ST ADD
LOT 0 0 1.000 14,000.00 $14,000
REPLAT PB 26 PGS 4 TO 6
BUILDING INFORMATION
Bid Num Bid Type Year Bit Fixtures Gross SF Heated SF Ext Wall Bid Value Est. Cost New
1 SINGLE FAMILY 1983 6 1,978 1,438 CONC BLOCK $76,288 $82,474
Appendage / Sgft GARAGE FINISHED / 500
Appendage / Sgft OPEN PORCH FINISHED / 40
NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax
purposes.
*** If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value.
http://www. scpafl.org/pls/web/re_web. seminole_county_title?parcel=10203050500000120,... 8/22/2003