HomeMy WebLinkAbout1201 Albright Rd (9)6p/1)r4R.-0 To14)z2 - �- 19(A)r, C;6pp � ALO 199 ` `A LjRgy I 4® r 14 0 E413 -G TWIN LAKES SBA SITE# FL 1224 (SANFORD) 1201 Albright Rd. Sanford, FL 32771 PROPOSED COMMUNICATION FACILITY CO -LOCATE ON 240' GUY TOWER JURISDICTION: CITY OF SANFORD SECTION27, TOWNSHIP 19 SOUTH, RANGE 30 EAST SEMINOLE COUNTY, FLORIDA GENERAL NOTES SYMBOLS SHEET INDEX . 1.. THE CONTRACTOR SHALL SUPERVISE AND DIRECT ALL WORK, USING HIS BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 2. THE CONTRACTOR SHALL VISIT THE JOB SITE TO REVIEW THE SCOPE OF WORK AND EXISTING JOB SITE CONDITIONS INCLUDING, BUT NOT LIMITED TO MECHANICAL, ELECTRICAL SERVICE, AND OVERALL COORDINATION. 3. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS, ETC. SHALL BE REPORTED BEFORE PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, OR EQUIPMENT, SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE TENANT OR BUILDING OWNER, OR OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 6. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON A REGULAR BASIS, AND SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING THROUGHOUT CONSTRUCTION, INCLUDING FINAL CLEAN-UP UPON COMPLETION OF WORK. ALL AREAS ARE TO BE LEFT IN A BROOM CLEAN CONDITION AT THE END OF EACH DAY. 7. THE CONTRACTOR SHALL SAFEGUARD THE SITE OWNER'S PROPERTY DURING CONSTRUCTION AND SHALL REPLACE ANY DAMAGED PROPERTY OF THE OWNER TO ORIGINAL CONDITION OR BETTER. 8. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CON- TRACTOR TO LOCATE ALL EXISTING UTILITIES. WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. 10. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED BY THE CITY OR GOVERNING AGENCY. 11. ALL CONSTRUCTION WORK SHALL CONFORM TO THE 2001 FLORIDA BUILDING CODE AND ALL OTHER GOVERNING BUILDING CODES. THE MOST RESTRICTIVE CODES WILL GOVERN. 12. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL COMPLY WITH ALL LOCAL CODE REGULATIONS AND STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL SAFETY (OSHA) REQUIREMENTS. REFER TO THE CODES SECTION OF THIS SHEET. 13. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE, AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS OFF-SITE, OR DO ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS KAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 14. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES WITHIN THE CONTRACT DOCUMENTS WITH THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS PRIOR TO EXECUTING THE WORK IN QUESTION. 15. CONTRACTOR SHALL NOTIFY THE ARCHITECT IF DETAILS ARE CONSIDERED UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED. IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO THE DETAIL. DETAILS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 16. CONTRACTOR TO FIELD VERIFY ALL MEASUREMENTS PRIOR TO CONSTRUCTION. ALL MEASUREMENTS ARE ASSUMED TO BE ACCURATE WITHIN REASON. NO PROFESSIONAL SURVEY WAS MADE OF THE PROPERTY FOR THIS PROJECT. THE CLIENT ASSUMES LIABILITY FOR INACCURACIES DUE TO THE LACK OF SURVEY AND STRUCTURAL ANALYSIS. 17. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CON- TRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 18. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORT FOR ALL OTHER ITEMS REQUIRING THE SAME. 19. CITY APPROVED PUNS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALI.,REVISIONS, ADDENDA_AND CHANCE_ ORDERS,._...._...,.- ON THE PREMISE AT ALE TIMES. THESE ARETO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. CODES ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF THE: 1.1 THE FLORIDA BUILDING CODE 1.4 NATIONAL ELECTRICAL CODE 2001, AND ALL LOCAL CODES IN WHICH THE PROJECT IS BEING 1.5 UNIFORM MECHANICAL CODE CONSTRUCTED. 1.2 INDUSTRIAL CODE (ANSI) 1.3 OCCUPATIONAL SAFETY AND HEALTH STANDARDS (OSHA) At SECTION LETTER A- SHEET NO. WHERE SECTION IS SHOWN 1 INT. ELEV. NO. Al ELEV. DWG. NUMBER 2 A-1 SHEET NO. WHERE DETAIL IS SHOWN 3 Al DETAIL NUMBER PM SHEET NO. Al DETAIL NO. PM SHEET NO. 2�-REVISION NUMBER DRIVING DIRECTIONS Ti TITLE PAGE C1 COMPOUND LAYOUT C2 RF INFO & DETAILS C3 CABINET DETAILS C4 CONSTRUCTION DETAILS E1 ELECTRICAL PLAN E2 GROUNDING PLAN E3 GROUNDING DETAILS E4 ELECTRICAL SCHEMATIC VICINITY MAP N C SI TE NTS 1 PIANS REVIE-EM" CITY OF SANFORD U z G w a z 0 FROM TAMPA, TAKE 1-4 EAST TO EXIT 101A (OLD 46A) EAST ON SSR46 FOR APPROXIMATELY 3.2 MILES TO AIRPORT ELVD. TURN LEFT ONTO AIRPORT BLVD. TRAVEL NORTH APPROXIMATELY 1.1 MILES TO ALBRIGHT RD. TURN LEFT ONTO ALBRIGHT RD SITE 15 AT END ON ROAD. d' JJK40 V) LLJ PROJECT TEAM N ABBREVIATIONS �CIE r? m r7 TOWER OWNER ELECTRICAL UTILITIES ARCH. ARCHITECT ELEV. ELEVATOR PL. PLATE SBA TOWERS INC. FPLEQ. AMP- AMPERE I- EQUAL P.V.C. POLYVINYL 990 HOLCOMB BRIDGE RD. N EQUIP. EQUIPMENT R.D. ROOF DRAIN STE. 2 BLDG. BUILDING EXIST. EXISTING REINF. REINFORCING ROSWELL, GA 30076 C.B. CATCH BASIN REO'D. REQUIRED ATTN: WENDY WALKERFIN. C.L. CENTER LINE FINISH PHONE: 770-330-8806 FTG FOOTING RM. ROOM TELEPHONE COMPANY CLC. CEILING GA GAUGE SCHED. SCHEDULE SITE OWNER SBA TOWERS INC. BELLSOUTH CONC. CONCRETE GALV GALVANIZED S.F. SQUARE FEET 990 HOLCOMB BRIDGE RD. CONST, CONSTRUCTION GND. GROUND SHT. SHEET STE. 2 CONTR. CONTRACTOR SIM. SIMILAR ROSWELL, GA 30076 DBL. DOUBLE GYP -BO. GYPSUM BOARD ATTN: WENDY WALKER DET. DETAIL LAM. LAMINATED SPECS. SPECIFICATIONS PHONE: 770-330-8806 STD. STANDARD DIA DIAMETER LT. WT. LIGHT WEIGHT L. STL STEEL DESIGNER ENGINEER OF RECORD DIAL. DIAGONAL L.F. LINEAL FEET ST STRUCTURAL ENHANCED GRAPHICS IMAGING MARK V. RICHTER P.E. DIM. DIMENSION M.H. MAN HOLE 2730 PENZANCE ST (813) 967-5270SUSP. MIN. MINIMUM SUSPENDED PALM HARBOR, FL 34684 ON. DOWN T.C. TOP OF CURB CHUCK REHM DWG. DRAWING MISC. MISCELLANEOUS T.O.P. TOP OF PAVING PHONE: (727) 644-6466 EA EACH N.T.S. NOT TO SCALE TYP TYPICAL FAX: (727) 771-9476 ELEC. ELECTRICAL O.C. ON CENTER T.O.S. TOP OF SLAB SHEET NUMBER: T-1 d' V) LLJ Lj N d �CIE r? m r7 Q LJi LLJ J Lit Z H O �- O I- Q N DATE: 10/14/03 .InR NO: E413 -G SHEET NUMBER: T-1 EXISTING 12'-0" DOUBLE SWING GATE 12'-0" 10'-0" LEASE AREA J W-8" PAD PROPOSED H -FRAME FOR TRICOM BOX V-0" opo oEo �TELCO D -MARK EXISTING LIGHTNING S PROTECTION a 0 o i N N O N EXISTING 8'x18' 4" VERIZaN - EQUIPMENT PAD 60'-1" 1 EXISTING POWER I POLE WITH TRANSFORMER EXISTING NATURAL. VEGETATION (TYP) EXISTING 6'-0" �1 tl I I FENCE EXISTING TELCO PROPOSED POWER I D -MARK DROP POLE EXISTING POWER DROP POLES c� m m z�x fel N D 70 x_ � EXISTING n w z 22 x16 -8 0 0 NEXTEL EQUIPMENT SHELTER EXISTING 12'x16' SPRINT EQUIPMENT PAD EXISTING SATELLITE DISH APPRQX. N�COMPOUND LAYOUT NORTH �/ SCALE: t" = t0' TOWER LIGHTING k NO HAZARD DETERMINATION PER APPLICABLE FAA PERMIT k STUDY REQUIREMENTS NOTE: EXISTING ANTENNAS NOT SHOWN FOR CLAIRITY / EXISTING 240' Z GUYED TOWER EXISTING EQUIPMENT SHELTER PROPOSED PROPOSED H -FRAME WAVEGUIDE FOR TRIGON 80X SUPPORTS I.LJ Wn a U s^ PROPOSED OUTDOOR EQUIPMENT CABINETS _ TOP OF TOWER ELEVATION AT 240'-0" PROPOSED VOICESTREAM ANTENNAS ELEVATION AT 160'-0" AGL SIX (6) COMSAT PCSX-065-18-02 PANEL ANTENNAS AND TWELVE (12) 1-5/8" COAX CABLES �o Z v m O W r a W2 n o I' I � a ch I.LJ Wn a U s^ a^ Z� O W W2 n g> �Y0^ M m M Z W OZ d �p W C'4 J p O LLJ QU ►-i—.,— N I, 1 rS DATE: 10/14/03_ -J-0B N0: E413 -G - _ DRAWN: CLB CHECKED: MR VIEW ATED SHEET NUMBER: ELEVATION WEST LOOKING EAST NOT TO SCALE C-1 i EXISTING TYPICAL COAX LAYOUT NOT TO SCALE l—EXISTING GUY TOWER 2}"0 x 6'-6" GALV. PIPE — \ GROUND CLAMPS PLATFORM RAI ;L\ � SUPPORT PIPE � n — — HANGERS I BUSS BAR WITH BEAM CLAMP DAXIAL CABLES 3' RY JUMPER LNA 6' RY JUMPER \ I I I I CABLE HOISTS \\VIIJII NOTE: PLATFORM DESIGNED BY OTHERS ANTENNA MOUNTING DETAIL NOT TO SCALE ANTENNA SUPPOF LNA GALVANIZED PL ANTENNA MOUN ALLOWABLE BENDING RADIUS NK CABLE TYP. COAX BENDING RADIUS 1/2" SUPERFLEX 3" 1/2" LDF F. 7/8" FOAM 12" 1-5/8" FOAM 24" ALLOWABLE BENDING RADIUS ANDREW CABLE TYP. COAX BENDING RADIUS 2-1/4" FOAM 28" BEND RADIUS TABLE NOT TO SCALE HEAD FRAME LAYOUT NOT TO SCALE NOTE: CONNECTIONS BETWEEN MAIN FEEDERS AND ANTENNAS ARE SHOWN FOR CLARITY AND DO NOT REPRESENT HOW THE ACTUAL JUMPERS SHOULD BE RUN. o o w o tiT L� CD L v J C9C)o N co J I 7 J ® U X L L< � < O 2j: N O U r� Zcf) cr O g 0 Z 3 0 0 a K C3 o a N �J ca� WQ O O C a N 1— COMSAT u�W N MQ PCSX-065-18-02 Qf w c ANTENNA W Zo z Q o 'H' JUMPER, 1/2 SUPERFLEX c Q TERRACOM o 3' PREMADE JOB NO: E413 -G DRAWN: CLB 6' RY JUMPER \ I I I I CABLE HOISTS \\VIIJII NOTE: PLATFORM DESIGNED BY OTHERS ANTENNA MOUNTING DETAIL NOT TO SCALE ANTENNA SUPPOF LNA GALVANIZED PL ANTENNA MOUN ALLOWABLE BENDING RADIUS NK CABLE TYP. COAX BENDING RADIUS 1/2" SUPERFLEX 3" 1/2" LDF F. 7/8" FOAM 12" 1-5/8" FOAM 24" ALLOWABLE BENDING RADIUS ANDREW CABLE TYP. COAX BENDING RADIUS 2-1/4" FOAM 28" BEND RADIUS TABLE NOT TO SCALE HEAD FRAME LAYOUT NOT TO SCALE NOTE: CONNECTIONS BETWEEN MAIN FEEDERS AND ANTENNAS ARE SHOWN FOR CLARITY AND DO NOT REPRESENT HOW THE ACTUAL JUMPERS SHOULD BE RUN. o o w o tiT L� CD L v J C9C)o N co J I 7 J ® U X L L< � < O 2j: N O U r� Zcf) cr O g 0 Z 3 0 0 a K C3 o a N �J ca� WQ O O C SHEET NUMBER: C-2 Z N 1— O J u�W N MQ I2 m M Qf w J Za LL OD w �o o Zo z Q o of z Q N DATE: 10/14/03 _ JOB NO: E413 -G DRAWN: CLB _ CHECKED: MR SCALE: AS NOTED SHEET NUMBER: C-2 ROUTE COAX UP TOWER PER STRUCTURAL — GROUND BAR— GROUND CLAMP - COAX SUPPORT SEE DETAILS ON 2' -6" 1 4'-0" WAVEGUIDE BRIDGE GROUNDING KIT A (TYP)� 6" PROPOSED OUTDOOR EQUIPMENT CABINETS 1 -III -III "'=III' -III SEE DETAIL BELOW 24" MIN / BEND COAX SUPPORT�J -RADIUS ANTENNA COAX JUMPERS (TYP) IIFIII -�I _III -I III 1L -III III-� -III III III -II; III 'I -III -III II! III -III_. 1i— TL it -I HI III=III Ili lit -1 -" I=J L=, IF" - CONCRETE PAD =i 3"0 GALVANIZE PIPE J1° COLUMN SUPPORT (TYP) BTS AND WAVEGUIDE. BRIDGE ELEVATION NOT TO SCALE PURCELL ULTRASITE ULTRASITE ULTRASITE CABINET CABINET CABINET CABINET NOTE: CONTRACTOR SHALL VERIFY ALL.VOICESTREAM WIRELESS EQUIPMENT SPECIFICATIONS PRIOR TO INITIATION OF CONSTRUCTION ACTIVITIES, GENERAL LAYOUT - SEE COMPOUND FOR ORIENTATION. 70" CONCRETE SLAB WITH FIBERMESH z 1" CHAMFER REINFORCEMENT AND A LIGHT BROOM FINISH OR PRECAST (EQUIVALENT) CONCRETE SLAB a TOP OF SLAB 1 a <a I PREPARED SUBGRADE COMPACTED TO 95% RELATIVE DENSITY BTS CABINET SLAB DETAILNOT TO SCALE NOTE: 1. CONCRETE SHALL CONFORM TO THE SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDING, ACI 301-89. CONCRETE SHALL BE MADE WITH STONE AGGREGATE AND SHALL DEVELOP A 4,000 PSI MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS. CONCRETE SHALL BE TESTED TO VERIFY 4,000 PSI COMPRESSIVE STRENGTH. 2. CONCRETE MIX DESIGN 6-1/2" SACKS MINIMUM PER CUBIC YARD. 5" MINIMUM, 7" MAXIMUM SLUMP, 3/4" MAXIMUM AGGREGATE. 1.5# OF SYNTHETIC FIBER REINFORCEMENT (FIBERMESH OR EQUIV) PER CUBIC YARD OF CONCRETE. 3. CAPPED CONDUIT STUB UPS UNDER UTILITY CABINET SHALL BE 6" ABOVE FINISHED SLAB. 4• EXACT POSITION OF BTS CABINETS ON SLAB SHALL BE DETERMINED IN THE FIELD. 5, COAX SUPPORTS TO BE SUPPLIED AND INSTALLED BY CONTRACTOR. 6. GROUND TO BE PROOFROLLED TO A MINIMUM BEARING OF 2500# PER S.F. PRIOR TO CONCRETE PAD CONSTRUCTION. 7• ALL EXPOSED EDGES SHALL BE CHAMFERED 1". 8. CONCRETE PAD IS DESIGNED TO BEAR ON 2000 PSF SOIL BEARING CAPACITY TO BE VERIFIED AT TIME OF EXCAVATION BY A SOILS ENGINEER REGISTERED IN THE STATE OF FLORIDA. 9. PRE -CAST CONCRETE PAD MAY BE USED IN PLACE OF POURED IN PLACE PAD AND SHALL BE USED AT THE CONTRACTORS DISCRETION. B'TS PAD LAYOUT NOT TO SCALE e cl- o U o N Ln N � O 1 Ln 00 V z c •— LL � G u Li Q C L_ LL CD O Z w a z 0 D N Z NH _J Q W= n ^ U v' ^ CDA9 o � I' I (3 ep ao m ✓f 11J B ^ i N N ^ F -p pm s^ aN F- N 0: QL. W r D N NH _J Q W= n (0 Y W Of p J m D J Za 1— W W Z F -p pm F- N 0: QL. O U z Q N OATF: 10/14/03 SHEET NUMBER: C-3 GALVANIZED PIPE CAP L3" x 2" x 1/4" s GALVANIZED PIPE POST CHANNEL SUPPORT KIT L3 1/2" x 2 1/2" x 1/4" COAXIAL CABLE WITH / ANDREW STAINLESS SNAP -IN HANGER " 3/8" x 6" SS THREADED R4 Y4 B4 RODS 1 AT EACH o 0 0 WAVEGUIDE (MICROFLECT 8164) (REPLACE WITH o 0 0 1/2" ROD IF NECESSARY) R3 Y3 83 COAX CABLE SUPPORT R1 Y1 Bt O O O BOOT AND CUSHION ASSEMBLY (MICROFLECT 0 0 0 8537) LR2 Y2 82 3" GALVANIZED SCHEDULE 40 PIPE COLUMN SUPPORT POSTS V-6' TO BE PLACED ON THE SAME SIDE OF BRIDGE AT 4'-0" O.C.- SEE SUPPORT PIPE FOUNDATION DETAILS BELOW FOR CONNECTION COLOR CODE SECTOR A: RED (R) SECTOR 8: YELLOW (Y) SECTOR C: BLUE (8) FINISH TRUSS SUPPORT (MICROFLECT 81117) 3/8" GALVANIZED NUT 4 AT EACH WAVEGUIDE CHANNEL SUPPORT I =III III—III—III—III- i I" Ti l l I I �I I I I-� =1 I I=1 I I-1 I I-1 11=1 NOTE: REFER TO RF SITE REPORT I I EMBED POST A MIN FOR CABLE ROUTING CONFIGURATION d OF 24" INTO PIER WAVEGUIDE SUPPORT DETAIL (CANTILEVER) NOT TO SCALE 3"0 GALVANIZED PIPE COLUMN SUPPORT 4"x 4"x 3/8" \ STEEL PLATE HLTI 3" IBOLT PROPOSED BTS CABINET ( TYP. OF 2)--� \ CONCRETE SLAB SoUPPORT PIPE FOUNDATION (IF REQUIRED) NTO SCALE • , ,• _ate. �: " - - �� 3"0 GALVANIZED PIPE COLUMN SUPPOI cof o w o CD Ln — LOQ \ z J 7 00 D Q LL e� GRIPSTRUT 14 GAUGE 24"W x 2"D I i G SUPPORT SINGLE POST DETAIL U V N 2 C9 1O Z n NOT TO SCALE Z Z 0 z t 0 "3j ow 2T 0117)� OFx w 2 w N an N � n N LJ o a � W o CDv n n 0 0 8 ��N N � SUPPORT SINGLE POST DETAIL V C9 1O Z n NOT TO SCALE (Q9 0f an N � n W o CDv 8 ��N N � 3"0 GALVANIZED v \\ _ PIPE COLUMN SUPPORT `, a it Ld DOMED CAP v° t h > w I 1 1 y � MIN 3000 PSI n CC Z I CONCRETE 2 O W ^ YFX U 1— N m'� J 5— I L W Z (n O U O U - WAVEGUIDE SUPPORT PIPE (FOOTING z NOT TO SCALE N DATE: 10/14/03 JOB NO: E413 -G DRAWN: CLB CHECKED: MR SCALE: AS NOTED SHEET NUMBER: C-4 EXISTING TELCO D -MARK /—PROPOSED POWER CONDUIT PROPOSED TELCO CONDUIT / FROM PROPOSED POWER POLE FROM EXISTING D -MARK PURCELL CABINET TO PROPOSED TRICOM mm z X vm— DLn D z 00 STING I� PROPOSED EXEQUIPMENT TRICOM BOX SHELTER El EXISTING EQUIPMENT PAD TRUE NORTH IVI NOT TO SCALE PROPOSED POWER DROP --- -----'� PROPOSED POWER DROP POLE PROPOSED POWER METER & DISCONNECT EXISTING TELCO D -MARK— RACEWAYS: USING (EMT) AS INDICATED ON THE DRAWINGS. 40 PVC AS INDICATED ON THE DRAWINGS. PROVIDE INSULATED BUSHING FOR ALL CONDUIT TERMINATIONS. ALL PROVIDE SUPPORTS FOR ALL CONDUITS IN ACCORDANCE WITH NEC REQUIREMENTS. ALL CONDUITS SHALL BE SIZED AS REQUIRED BY NEC. CONDUCTORS: STATE, AND FEDERAL AUTHORITIES HAVING JURISDICTION. CONFORM TO THE SCOPE: DROP FROM SHALL INCLUDE ALL LABOR, MATERIALS AND APPLIANCES REQUIRED EXISTING POWER FOR THE FURNISHING, INSTALLING AND TESTING, COMPLETE AND READY POLE WITH FOR OPERATION OF ALL WORK SHOWN ON THE DRAWING AND AS TRANSFORMER SPECIFIED HEREIN: FINAL ACCEPTANCE OF WORK. 1. ELECTRIC SERVICE j O p 2. CONDUIT AND RACEWAY TESTING: 3. CONDUCTORS UPON COMPLETION OF THE INSTALLATION, OPERATE AND ADJUST ALL 4. MISCELLANEOUS MATERIALS (SWITCHES, BOXES, ETC.) EQUIPMENT AND SYSTEMS TO MEET SPECIFIED PERFORMANCE REQUIREMENTS. 5. TELEPHONE SERVICE ALL TESTING SHALL BE DONE BY QUALIFIED PERSONNEL. 6. ALL WORK SHALL BE DONE BY QUALIFIED PERSONNEL. Q CODES: GUARANTEE: INSTALLATION SHALL COMPLY (IN EFFECT AT TIME OF CONSTRUCTION) TO IN ADDITION TO THE GUARANTEE OF THE EQUIPMENT BY THE MANUFACTURER, THE REQUIREMENTS OF ALL RULES REGULATIONS AND CODES OF LOCAL RACEWAYS: USING (EMT) AS INDICATED ON THE DRAWINGS. 40 PVC AS INDICATED ON THE DRAWINGS. PROVIDE INSULATED BUSHING FOR ALL CONDUIT TERMINATIONS. ALL PROVIDE SUPPORTS FOR ALL CONDUITS IN ACCORDANCE WITH NEC REQUIREMENTS. ALL CONDUITS SHALL BE SIZED AS REQUIRED BY NEC. CONDUCTORS: STATE, AND FEDERAL AUTHORITIES HAVING JURISDICTION. CONFORM TO THE BE UL LISTED AND SHALL BE PROVIDED AND INSTALLED AS FOLLOWS: NATIONAL ELECTRICAL CODE AND ALL RULES, ORDINANCES OF THE ULTRASITE SERVING UTILITY COMPANIES. OBTAIN, PAY FOR AND DELIVER ALL PERMITS, A. MINIMUM WARE SIZE SHALL BE N12 AWG. CERTIFICATES OF INSPECTIONS, ETC. REQUIRED BY THE AUTHORITIES CABINET HAVING JURISDICTION. DELIVER ALL CERTIFICATES TO OWNER AFTER B. ALL CONDUCTORS SIZE q8 AND LARGER SHALL BE STRANDED. FINAL ACCEPTANCE OF WORK. CONDUCTORS SIZED #10 AND SMALLER SHALL BE SOLID OR j O p STRANDED EXCEPT AS NOTED ON DRAWING. TESTING: C. CONNECTION FORq10 AWG AND SMALLER SHALL BE BY TWISTING UPON COMPLETION OF THE INSTALLATION, OPERATE AND ADJUST ALL TIGHT AND INSTALLING INSULATED PRESSURE OR WIRE NUT EQUIPMENT AND SYSTEMS TO MEET SPECIFIED PERFORMANCE REQUIREMENTS. CONNECTIONS. ALL TESTING SHALL BE DONE BY QUALIFIED PERSONNEL. D. CONNECTION FOR p8 AWG AND LARGER SHALL BE BY USE OF Q STEEL CRIMP -ON SLEEVES WITH NYLON INSULATOR. GUARANTEE: IN ADDITION TO THE GUARANTEE OF THE EQUIPMENT BY THE MANUFACTURER, ALL CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC STANDARDS. EACH PIECE OF EQUIPMENT SPECIFIED HEREIN SHALL ALSO BE GUARANTEED CUTTING, PATCHING AND EXCAVATION: FORQ�FECTS OF MATERIAL OR WORKMANSHIP OCCURRING DURING A PERIOD OF THE RACEWAY SYSTEM SHALL BE COMPLETE BEFORE INSTALLING ONE (1 YEAR FROM FINAL ACCEPTANCE OF THE WORK BY THE OWNER. REPAIR CONDUCTORS. OR R LACE ALL DEFECTIVE PARTS OR SYSTEMS DURING THE GUARANTEE PERIOD TO THE CONSTRUCTION OF ANY PORTION OF THE WORK. ALL CUTTING AND WITHOUT AND O THE OWNER. ALL WARRANTEE TTO SE 7MANUFACTURERS �I-���_�j ' FURNIISHEDXBYNTHE THE OWNERES SHALL BE TURNED OVER . GROUNDING: GROUNDING: _ ALL ELECTRICAL NEUTRALS, RACEWAYS AND NON-CURRENT CARRYING OF SITE: PARTEXAMINATION HNNEC SARTIICLE CTHIS E ALL NO STRUCTURAL MEMBER MAY BE CUT WITHOUT APPROVAL FROM A STRUCTURAL BE GROUNDEDINACCORICAL DANCE NTIPMENT SHALLOSURES 250.ATED PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL VISIT THE SITE OF ENGINEER. ALL NECESSARY EXCAVATIONS AND BACK FILLING INCIDENTAL i0 THE WORK, UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWING, SHALL BE THE JOB AND. SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS GROUND BUSSES, ETC. THE NEUTRAL CONDUCTOR FOR EACH SYSTEM AFFECTING THE PROPOSED ELECTRICAL INSTALLATION AND SHALL MAKE SHALL BE GROUNDED BY ONE POINT ONLY. PROVISIONS AS TO THE COST THEREOF. FAILURE TO COMPLY WITH THE INTENT OF THIS PARAGRAPH WALL IN NO WAY RELIEVE THE CONTRACTOR OF PROVIDE GROUND CONDUCTOR IN ALL RACEWAYS. / PURCELL PERFORMING ALL WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM ULTRASITE ULTRASITE OR SYSTEMS. YCD � CABINET MATERIAL AND EQUIPMENT: CABINET CABINET .MATERIAL AND EQUIPMENT INSTALLED AS A PART OF THE PERMANENT j O p � 1- U o�3 INSTALLATION SHALL BE NEW UNLESS OTHERWISE INDICATED OR SPECIFIED ELECTRICAL PLAN O AND SHALL BE LISTED BY AN APPROVED REGISTERED TESTING LABORATORY, FOR INSTALLATION IN EACH PARTICULAR CASE WHERE STANDARDS HAVE BEEN Q ESTABLISHED. ALL ELECTRICAL EQUIPMENT SHALL BE PROPERLY IDENTIFIED N AND NARKED INCLUDING WARNING LABELS AND SIGNAGE PER NEC. PROVIDE UTILITY MARKER TAPE 4" LAYER OF STONE CUTTING, PATCHING AND EXCAVATION: BURIED 12 BELOW WHERE REQUIRED COORDINATION OF ALL SLEEVES, CHASES, ETC., WILL BE REQUIRED PRIOR FINISHED GRADE TO THE CONSTRUCTION OF ANY PORTION OF THE WORK. ALL CUTTING AND �I-���_�j ' PATCHING OF WALLS, PARTITIONS, FLOORS, AND CHASES IN CONCRETE, aZ _ WOOD, STEEL OR MASONRY SHALL BE DONE AS PROVIDED ON THE DRAWINGS. Lu w -III—III - NO STRUCTURAL MEMBER MAY BE CUT WITHOUT APPROVAL FROM A STRUCTURAL _ UNDISTURBED SOIL ENGINEER. ALL NECESSARY EXCAVATIONS AND BACK FILLING INCIDENTAL i0 THE WORK, UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWING, SHALL BE to 0 1 COMPACTED BACKFILL 0 Z 7 2'-0^ Z N 2" TELCO PVC CONDUIT _ SQUARE MOUNTED n1 2"1* POWER PVC CONDUIT W/ BOLTS TO POSTCHANNEL TELCO TRICOM BOX UTILITY TRENCH DETAIL NOT TO SCALE 1-2" PVC CONDUIT TO PROPOSED H -FRAME EXISTING TELCO POLE —i r•_ f I \� o ?---------� �- 1 } I r1 � � � � I i •I -------L----------------------------------------�—�:'----- 1j — I LI OEM VOICESTREAM SHALL PROVIDE CONTRACTOR WITH A COPY OF LATEST VOICESTREAM STANDARD CONSTRUCTION DETAILS. ALL CONSTRUCTION SHALL COMPLY WITH LATEST VOICESTREAM STANDARD CONSTRUCTION DETAILS. UPON COMPLETION OF INSTALLATION, THE SYSTEM TO BE' TESTED IN ACCORDANCE WITH VOICESTREAM STANDARDS. r- o LTJo T Ln N CD Ln �J (_0 CC) N DO �Q o� i �J� o� Y J < s a z 0 c Z ^ a C7 � i ALL CONNECTIONS TO GROUND BAR AND GROUND BAR MOUNTINGS. U W g.^_. INCLUDING BOLTS, AND THE POINTS OF CONTACT BETWEEN DISSIMILAR CD METALS MUST BE COATED WITH NO -OX." 3 0 r� r:j ALL MISCELLANEOUS NON-CURRENT CARRYING METAL ON THE SERVICE n c N CONNECTIONS SHALL BE EXOTHERMIC WELDS. W UTILITY SERVICES: (aJ a U s CONTRACTOR IS RESPONSIBLE FOR BRINGING POWER AND TELEPHONE SERVICES TO THE LEASE PARCEL. CONTRACTOR SHALL COORDINATE ALL a ^ REQUIREMENTS WITH POWER COMPANY AND TELEPHONE COMPANY. CONTRACTOR SHALL INCLUDE THESE SERVICES IN HIS WORK. MINIMUM SIZE WIRE BASED ON TOTAL ANTICIPATED SERVICE IS SHOWN AS WELL a AS APPROXIMATE DISTANCE TO CLOSEST AVAILABLE SOURCE. r � Urn �• TELCO CONDUIT TO BTS CABINETS, Fr PER MANUFACTURERS SPECIFICATIONS = j w c (1)-2" PVC IN FOR POWER -2" PVC IN FOR TELCO SERVICE RACK CONDUIT TABLE . ..I 001 I I d I I •i If :7 L SERVICE RACK RISER DIAGRAM NOT TO SCALE o PURCELL ULTRASITE ULTRASITE ULTRASITE J CL N YCD � CABINET CABINET CABINET CABINET U W D j O p � 1- U o�3 F" CV Of W O W Z Q . ..I 001 I I d I I •i If :7 L SERVICE RACK RISER DIAGRAM NOT TO SCALE o z � a F- J CL N YCD � J mM aF- J J U W D j O p � 1- U o�3 F" CV Of W O W Z Q N DATE: 10/14/03 JOB NO: E413 -G DRAWN: CL8 CHECKED: MR SCALE: AS NOTED SHEET NUMBER E-1 GROUND ROD WITH ACCESS ♦ (TYP 2 PLCS) I 1 I ♦ v /2 AWG SOLID, TINNED BCW TO WAVECUIDE BRIDGE POSTS GROUNDING PLAN NOT TO SCALE p2 AWG SOLID, TINNED BCW (RING GROUND) p2 AWG SOLID, TINNED BCW TO ANTENNA CABLE GROUND 02 AWG SOLID, TINNED BCW TO EXISTING TOWER GROUND (2 PLACES) /2 AWG SOLID, TINNED BCW TO TOWER GROUND BAR o cl:� O r L Ln r 1 GROUNDING NOTESco 1. BARE GROUND WIRE SHALL BE COPPER, CLASS A OR B, TINNED SOLID IN ACCORDANCE WITH ASTM 96. WIRE SHALL SIZED IN ACCORDANCE WITH THE NEC EXCEPT WHERE THE SIZES SPECIFIC HEREIN ARE LARGER THAN THOSE REQUIRED BY THE NEC. r � a 2. INSULATED GROUND WIRE SHALL BE CLASS B. STRANDED, 600 VOLT, 90 DEGREE C, XHHW, INSULATED z_ u AND JACKETED IN ACCORDANCE NTH NEC. ® `s ate`. C J X 3. COMPRESSION TYPE CLAMPS SHALL BE HIGH STRENGTH ELECTRICAL BRONZE WITH SILICON BRONZE Q O CLAMPING BOLTS AND HARDWARE. BOLTS, NUTS, LOCK WASHER, AND SIMILAR HARDWARE SHALL BE DESIGNED NOT TO DAMAGE GROUND WIRE. 4. THERMIT WELDED CONNECTORS SHALL BE LETTER -CODED, EXOTHERMICALLY WELDED TYPE. CONNECTORS SHALL BE CADWELD OR EQUAL. CONNECTORS TYPE SHALL INCLUDE: - CABLE TO CABLE "Y" CONNECTORS - STRUCTURAL STEEL TO GROUND CABLE CONNECTORS o - CABLE TO GROUND ROD CONNECTORS G s 5. GROUND ROD SHALL BE 5/8" DIAMETER AND 8 FEET LONG, COPPER CLAD STEEL. w CL 6. FINISHED GROUND RING(S) SHALL BE MEASURED USING A "MEGGER" AND SHALL BE 5 OHMS OR LESS TO s EARTH. u 7. EACH CABLE TRY/ICE BRIDGE POST SHALL BE BONDED TO THE BTS GROUND RING WITH AWG p2 BARE �z' _ TINNED SOLID COPPER AND EXOTHERMIC WELDS. $. 8. GROUND ROD SPACING SHALL BE 8 FEET. SUFFICIENT RODS SHOULD BE USED TO ACHIEVE THE REQUIRED z o o RESISTANCE OF 5 OHMS OR LESS. O a = W 9, IF A TOWER IS BUILT, THEN TWO GROUNDING RINGS ARE CONSTRUCTED, ONE FOR THE TOWER, AND ONE W o N FOR THE EQUIPMENT. � m n n 10. INSTALL UTILITY CABINET IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. w 0 — 0 11. CONDUCTIVE NON -OXIDATION COMPOUND SHALL BE APPLIED TO ALL GROUND BARS, STRAPS, ENDS OF 0 0 CONDUCTORS, CONNECTORS, ETC. BEFORE MAKING THE CONNECTION. ALL GROUNDING SURFACES SHALL BE CLEAN AND FREE OF PAINT OR CORROSION. o - 12. ALL LUGS OR CONNECTORS SHALL BE OF A TYPE APPROVED FOR THE APPLICATION AND COMBINATION OF 10 n MATERIALS AND SHALL BE EQUIPPED WITH TWO MOUNTING HOLES. Z_ Y 0 O 13. ONLY ;THE GROUNDING LEAD SHALL BE ATTACHED WITH THE SAME MOUNTING BOLT(S) AND IF THE q� F CONNECTOR HAS TWO HOLES, IT SHALL BE SECURED USING BOTH HOLES. — + n 14. ALL CONNECTIONS TO THE GROUND RINGS ARE TO BE MADE WITH A SWEEP TO EARTH. ANY BENDS AREN U r" TO HAVE A NOMINAL RADIUS OF 12 INCHES AND 90 DEGREE BENDS ARE TO BE AVOIDED. �' 15. MAINTAIN 2 FEET SEPARATION BETWEEN GROUNDING CONDUCTORS INSTALLED TO THE GROUND RING. ALL OTHER CONDUCTORS ARE TO HAVE SEPARATION (NO BANDS OR TIES) NON-METALLIC SEPARATORS AND I ' (L�`"' STAND-OFFS CAN BE USED. n 16. ALL GROUNDING WORK MOST BE IN COMPLIANCE WITH VOICESTREAM WIRELESS COMMUNICATIONS BTS 3 GROUNDING GUIDELINES: RAW LAND SITES, VER. 2.1 OR LATER. a 17. COAX FEEDER TO BE GROUNDED AT 3 PLACES, TOP OF TOWER, BOTTOM OF TOWER & JUST BEFORE TRANSITION TO JUMPER TERMINATE LATER KITS TO UTILITY CABINET GROUND BAR. _ 18. IF VERTICAL SPAN IS GREATER THAN 200 FEET A GROUND CONNECTION SHALL BE MADE TO EACH FEED n AT MID -POINT, z�rn 19. ALL CONNECTIONS SHALL BE EXOTHERMIC (CADWELD OR EQUIVALENT) UNLESS INDICATED OTHERWISE. �N 20. ALL GROUNDING CONNECTIONS MADE THROUGHOUT THIS DRAWING SHALL BE MADE WITH THOMAS AND - j w � BETTS KOPR-SHIELD (TM OF JET LUBE INC.). COAT ALL SURFACES BEFORE CONNECTING. Y d 21. DUE TO THE INDEPENDENT NATURE OF BOTH THE SERVICE GROUND AND THE EQUIPMENT BOND SYSTEM,` LL l THE CONTRACTOR SHALL TEST BOTH SYSTEMS AFTER INSTALLATION AND SHALL SHOW THAT BOTH SYSTEMS MEET THE 5 OHM OR LESS CTITERIA AND THAT THERE IS AN EQUIVALENCE OF NO POTENTIAL DIFFERENCE BETWEEN THE TWO. TEST RESULTS AND A STATEMENT OF THE OUTCOME SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND RECORD PURPOSES. SOME JURISDICTIONS MAY REQUIRE A PHYSICAL CONNECTION BETWEEN THE TWO SYSTEMS. IN THESE CASES THE CONTRACTOR SHALL COMPLY BY CONNECTING THE TWO WITH A SINGLE CONDUCTOR, "p2 AWG, BARE, TINNED, SOLID COPPER CONNECTED BY EXOTHERMIC WELD AT C BOTH ENDS". Z Q J 22. AT A MINIMUM, GROUNDING SHALL COMPLY WITH THE 2001 FLORIDA BUILDING CODE. � Y LD ^ CI_ t/) 23. GROUNDING KITS TO BE LOCATED IN FOUR LOCATIONS: m � C' Lj Z - AT TOP OF TOWER 1' TO 2' FROM MAIN LINE CONNECTORS, Q J O - AT BOTTOM OF TOWER BEFORE BENT, Lv 'z Z - AT BOTTOM OF TOWER AFTER BENT 1' TO 2' FROM MAIN LINE CONNECTORS. Z - AT MIDPOINT OF VERTICAL SPAN ON TOWER (APPROX 95') N c O O Z Q ELECTRICAL SYMBOLS: DATE: 10/14/03 JOB NO: E413 -G ® GROUND ROD WITH INSPECTION HAND HOLE DRAWN: CLB ® GROUND ROD CHECKED: MR • CADWELD TYPE CONNECTION SCALE: AS NOTED SHEET NUMBER: GROUND BAR —"—'— BURIED GROUNDING WARE E-2 COAX GROUND KIT ZIP TIE CONNECTOR 3"0 GALVANIZED EXOTHERMIC WELD PIPE COLUMN SUPPORT COLD GALVANIZE �— AFTER COOLING----_ NO-OXSIDES (BOTH / f SIDES OF LUG) —/ / PIGTAIL SCREW — �12 COAX GROUND DETAILq2 AWG BARE, TINNEE SOLID COPPER GROUN NOT TO SCALE WIRE TO BTS GROUND NOTES: RING 1) CABLE TRAY NOT SHOWN FOR CLARITY. 2) CONTRACTOR TO COORDINATE WITH ANTENNA MANUFACTURER ON ANTENNA AND COAX CABLE GROUND BAR SPACING FOR PROPER GROUNDING 3) GROUNDING KITS TO BE LOCATED IN FOUR LOCATIONS: - AT TOP OF TOWER 1' TO 2' FROM MAIN LINE CONNECTORS, - AT BOTTOM OF TOWER BEFORE BENT, - AT BOTTOM OF TOWER AFTER BENT 1' TO 2' FROM MAIN LINE CONNECTORS. - AT MIDPOINT OF VERTICAL SPAN ON TOWER (APPROX 95') UPPER ANTENNA GROUND BAR CLIUSTER MOUNTED DIRECTLY SUPPORT TO TOWER WITH OUT INSULATORS --w—L., NOT TO SCALE WAVEGUIDE BONDING DETAIL NOT TO SCALE TO GROUND BAR y2 SOLID COPPER TINNED, TO STRUCTURE OR GROUND BAR EXOTHERMIC WELDS 02 AWG BARE SOLID COPPER TINNED, GROUND RING — CONNECTIONS TO GROUND RING FROM GROUND BARS AND STRUCTURAL DETAIL NOT TO SCALE ENGRAVED COVER MARKED "GROUND ELECTRODE" FLUSH WITH FINISHED GRADE 10"0 WHITE PVC DRIVING STUD & COUPLING INSPECTION SLEEVE IF (RE-USE FOR EACH INSTALLATION) GRADE OR PAVING NO MAIN GROUND CONDUCTORIV Y SEE PLAN DWG FOR NUMBER EXOTHERMIC WELD & SIZE OF CONNECTIONS J • CONNECTION GROUND ROD, 5/8" x 8'-0" COPPER CLAD STEEL GROUND ROD & TEST WELL NOT TO SCALE 1 6010 GROUNDING �00� 0 ' CABLE TWO HOLE COPPER Z TERMINAL (SHOWN p2 AWG BARE, TINNED, NO OX APPLIED AS BACK TO BACK SOLID COPPER WIRE BEFORE CRIMP CONNECTION) • o i NO OX NO OX —1 HEX BOLT EXOTHERMIC WELD / GROUND BAR PLATE NUT (TYPICAL) DRIVEN COPPER CLAD GROUND ROD 5/8"x8'-0" FLAT WAS LOCK WASHER (1) EVERY 8- (TYPICAL) (TYPICAL) FLAT WASHER (TYPICAL) COAXIAL CABLES , NOTE: CONNECTIONS'DOUBLING UP' OR 'STACKING' OF IS T PERMITTED. OXIDE INHIBITING JOINT COMPOUNDTO BE NOTE: INSPECTOR MUST USED ON ALL CONNECTIONS &ADDED PRIOR TO ADDING SIGN OFF IN WRITING BEFORE HARDWARE TO GROUND BAR. BACK TO BACK CONNECTIONS ANY BACKFILL SHALL BE USED ONLY WHEN NUMBER OF CONNECTIONS TO FRONT OF BAR EXCEEDS NUMBER OF AVAILABLE SPACES. GROUND ROD f RING LOCATION GROUND BAR CONNECTION NOT TO SCALE NOT TO SCALE LOWER ANTENNA GROUND BAR - GUYED TOWER (LOCATED BELOW MOUNTING BRACKET I/O ON (E) OR q2 AWG TINNED COPPER TO MIDDLE (N) TOWER) AND TOP GROUND BAR WITH INSULATORS d 2 EXISTING WAVEGUIDE LADDER NISH GRADE /\' o lLOWER TOWER SOLID BAR e BOLTED LUG (MOUNTED ON INSULATORS) j SEE DETAIL THIS SHEET BOND CONDUCTOR TO GROUND BAR USINSEE DETOTHS AILISHEET y2 AWG BARE SOLID, TINNED COPPER CONDUCTOR. SLEEVED IN 3/4" PVC ---­_� Z 0 In io n ZIP TIE GROUND KIT CONNECTOR � COAX LIGHTNING ARRESTOR � ANDREW VOICESTREAM //7��rDFDM-g o cl� o w o CD r -J C-0CC D I-- ,,, r'7 00 e � c) I z u .- x L- CD i G s w z 0 0 Z i NCL -OX (BOTH JUMPER TO BTS n 9863 H IDES LUG CONNECTOR F LUG) 12" APPLY NO -OX TO (A SCREW �' _ CONNECTION U W A� CDPIGTAIL TO UTILITY CABINET GROUND BAR W V, as R: rn NOTE: N ONLY LINES A3, A4, 83, B4, C3, AND C4 ARE TO RECEIVE LIGHTNING ARRESTORS a ^ LIGHTNING ARRESTOR DETAIL Z NOT TO SCALE - a CK T s_ B• 1. 1/4"x 4" FOR TOP/TOWER (3 REQUIRED, EACH TO V SUPPORT MIN. 6 CONDUCTORS) - W 7, 0 2. 1/4"x 4"W FOR BASE/TOWER (1 REQUIRED, MUS \: s a SUPPORT MIN. 13 GROUND CONDUCTORS) - Q `i. 3. SOLID CU BAR PRE -DRILLED (1 REQUIRED ATI.MIDt-YYO= `_ -. MUST SUPPORT MIN 13 GROUND CONDUCTORS) _ 4. ALL BARS DRILLED FOR 2 HOLE LUGS WITH .1 SPACING� c - TOWER GROUND BAR N p J NOT TO SCALE =( 0',,\ Q W TO COAX GROUND KITS Y ^v` 1-1 1BINETr— - - - - - - WALL OF NEW GROUND CABINET I NOTES: BARE I. USE EXISTING BOLTS: PROVIDE NUT & g ADDITIONAL STAINLESS OR BRONZE LOCKWASHER I NUTS & LOCKWASHERS. �O p Z 2. USE NO -OX BEFORE BOLTINGTERMINATE O O EXISTING = ON CABINET. TOWER FOUNDATION 0 Q O GROUND CABLES IN 3. APPLY NO -OX TO ENTIRE CABINET UNDER GROUND BAR BEFORE MOUNTING 0 0 v NUT & LOCKWASHER t I AND TERMINATING. BARE METAL & NO -OX BARE METAL & NO -OX ' GROUND BAR BOLT MOUNTING DETAIL NOT TO SCALE I L__ y2 AWG BARE SOLID, TINNED COPPER CONDUCTOR. SLEEVED IN 3/4" PVC ---­_� Z 0 In io n ZIP TIE GROUND KIT CONNECTOR � COAX LIGHTNING ARRESTOR � ANDREW VOICESTREAM //7��rDFDM-g o cl� o w o CD r -J C-0CC D I-- ,,, r'7 00 e � c) I z u .- x L- CD i G s w z 0 0 Z i NCL -OX (BOTH JUMPER TO BTS n 9863 H IDES LUG CONNECTOR F LUG) 12" APPLY NO -OX TO (A SCREW �' _ CONNECTION U W A� CDPIGTAIL TO UTILITY CABINET GROUND BAR W V, as R: rn NOTE: N ONLY LINES A3, A4, 83, B4, C3, AND C4 ARE TO RECEIVE LIGHTNING ARRESTORS a ^ LIGHTNING ARRESTOR DETAIL Z NOT TO SCALE - a CK T s_ B• 1. 1/4"x 4" FOR TOP/TOWER (3 REQUIRED, EACH TO V SUPPORT MIN. 6 CONDUCTORS) - W 7, 0 2. 1/4"x 4"W FOR BASE/TOWER (1 REQUIRED, MUS \: s a SUPPORT MIN. 13 GROUND CONDUCTORS) - Q `i. 3. SOLID CU BAR PRE -DRILLED (1 REQUIRED ATI.MIDt-YYO= `_ -. MUST SUPPORT MIN 13 GROUND CONDUCTORS) _ 4. ALL BARS DRILLED FOR 2 HOLE LUGS WITH .1 SPACING� c - TOWER GROUND BAR N p J NOT TO SCALE =( 0',,\ Q W TO COAX GROUND KITS Y NOTE: EXOTHERMIC WELD TO BURIED GROUND CARRIER COAX TO BE RING. CONNECTIONS TO GROUND RING BUNDLED AT TOWER LEG SHALL BE AS DIRECT AS POSSIBLE WITH MINIMUM BENDS. TYPICAL TOWER EXIT BAR DETAIL NOT TO SCALE BOLT THROUGH TO I DATE: 10/1' UTILITY CABINET I JOB NO: E413- 4" 9_ ,I DRAWN: CLS TO GROUND CHECKED: MR SCALE: AS N TO GROUND RING RING SHEET NUMBER: UTILITY CABINET GROUND BAR E-3 NOT TO SCALE ^v` 1-1 1BINETr— - - - - - - m `N _ BTS CA III -III III—III III.. ILL III— w za o �O p Z O O ~ p TOWER FOUNDATION 0 Q O 0 0 N NOTE: EXOTHERMIC WELD TO BURIED GROUND CARRIER COAX TO BE RING. CONNECTIONS TO GROUND RING BUNDLED AT TOWER LEG SHALL BE AS DIRECT AS POSSIBLE WITH MINIMUM BENDS. TYPICAL TOWER EXIT BAR DETAIL NOT TO SCALE BOLT THROUGH TO I DATE: 10/1' UTILITY CABINET I JOB NO: E413- 4" 9_ ,I DRAWN: CLS TO GROUND CHECKED: MR SCALE: AS N TO GROUND RING RING SHEET NUMBER: UTILITY CABINET GROUND BAR E-3 NOT TO SCALE TELCO EQUIP. BACK BOARD GFI (3) /12 AWC CU IODA 120/240V 1 -PHASE LIDA CAB. UTILITY DISTRIBUTION ASSEMBLY 6661-3006-01 NEMA 313 LABARGE INC. (FURNISHED BY OWNER, INSTALLED BY SUBCONTRACI TELCO CABLE DOWN TO NETWORK INTERFACE (BY OTHERS) 20A SINGLE POLE BREAKER NEUTRAL SOA 15A OR 20A ri TELCO CABINET ----------------- NO BOND TO NEUTRAL IN UTILITY CABINET F--- (2)x12 (1)#4GND-2'C AIN BREAKER 60A, SINGLE 2 POLERECEPTACLE FOR GENERATOR POWER INTERFACE ___ TO BTS CABINET TELCO INTERFACE (BY OTHERS) ONE -LINE DIAGRAM - ELECTRICAL NOT TO SCALE 3 p2/0, 1#4GND-2"C r- 3 p2/0 1g4 GND-2"C POWER SOURCE \ '--UTILITY APPROVED METER BASE (BY CONTRACTOR) AND METER (BY UTILITY) X100 AMP FUSED SAFETY DISCONNECT #4 GND TO (2) INDEPENDENT 5/8"x B'-0" GROUND RODS NOTE: INCREASE CONDUCTORS BY ONE SIZE FOR LENGTHS EXCEEDING 100 FEET INCREASE THEREAFTER AT 1110 FOOT INCREMENTS. ELECTRICAL SPECIFICATIONS 1. SCOPE: Provide labor, materials, and equipment, etc., required to complete the installation shown on the drawings. 2. CODES AND STANDARDS: Installation shall comply with applicable lows and ordinances, utility company regulations and applicable requirements of latest editions of: a. NFC - National Fire Codes b. UL - Underwriters Laboratories C. NEC - National Electrical Code d. NEMA - National Electrical Manufacturers Association e. OSHA - Occupational Safety and Health Act f. FBC - 2001 Florida Building Code 3. PERMITS: Obtain and pay for required permits, licenses, fees, inspections, etc. 4. COORDINATION: Coordinate work with other trades. - 5. SUBMITTALS: Submit brochures for approval on service disconnecting means and other major system components. 6. EXISTING SERVICES: Do not interrupt existing services without written permission of the Owner. 7. EQUIPMENT: Connect electrically operated equipment. 8. RECORD DRAWINGS: Maintain o record of all changes, substitutions between work as specified and installed. Record changes on a clean set of contract documents which shall be turned over to the Owner upon completion of the project. 9. IDENTIFICATION: ,Identify service disconnecting means with permanent nameplate. 10. GUARANTEE/WARRANTY: Guarantee installation to be free of defects, shorts, grounds, etc., for o period of one year. Furnish warranty so the defective materials and/or workmanship will be repaired/replaced immediately upon notification at no cost to the Owner for period of worronty. 11. CUTTING AND PATCHING: Provide cutting required to do the work. Do not cut major structural elements wi)hout approval. Patching shall be of quality equal to and of matching appearance of existing construction. 12. TRENCHING AND BACKFILL: Provide for oil underground installed conduit and/or cables. 13. RACEWAYS: Underground conduit shall be Schedule 40 PVC conduit (meet NEMA TC2 - 1990), except power service conduit, which shall be torcoated and grounded rigid galvanized steel grounded at both ends. Exposed conduit shall be rigid galvanized steel conduits, except conduits for grounding, which shall be PVC. Underground PVC conduit shall transition to rigid golvonized steel conduit before rising above grade. Plug and cop each of spare and empty conduits and provide pull string - 200 Ib. test polyethylene cord. All conduit bends shall be o minimum of 24" radius. GRS conduits when specified, shall meet UL -6 for galvanized steel. All fittings shall be suitable and clamps. Do not use perforated strops or tie wires. One -hole strops shall not be used for conduit larger than 3/4'. Use conduit seals for conduits penetrating building walls below grade. 14. SUPPORTS: As required by the NEC. 15. CONDUCTORS: Use 98% conductivity copper with type XHHW-2 insulation, 600 volt, color coded. Use solid conductors for wire up to and including No. 8 AWG. Use stranded conductors for wire above No. 8 AWG. 16. ENCLOSURES: Wet Locations or Outdoor - NEMA 3R Dry Locations or Indoor - NEMA 1 17. CONNECTORS FOR POWER CONDUCTORS: Use pressure type insulated twist -on connectors for #10 AWG and smaller. Use solderless mechanical terminal lugs for /8 AWG and larger. 18. SERVICE: 240/12OV, single phase, 3 wire connection available from Utility Company. Coordinate and pay all fees. 19. TELEPHONE SERVICE: Provide empty conduits with pull wires as indicated on drawings. 20. LABELS: Label meter can and disconnect with block plastic label with white letters. Label should read "voicestreom wireless and site address. Labels should be offixed in accordance with loco] utility guidelines. r- O w O L Ln N N J SO N C �zO�c �00 < o� Ilk �:: '5 L_ 0 Z U < i s W a Z 0 U V) 0 0 � U Z co Z LLo O 7, W 'Mnin W W o i lY w O �\ Z_ a n Z� a' W a $� N n V 3 n aN Z W = FIE M a w.� s� � O Q Z �\ U (- _J N I— LAJ LJ = r` = N N W FIE M F— M Z Q � O Q Z LSI Q N F— r O 0 U Lil N Li-] E413 -G CLS SHEET NUMBER: E-4 —__X_ PARTIAL SITE PIAN GENEmL DATA AND'SPECIFICATIONS 1. PROVIDE ALL WORK IN ACCORDANCE WITH LOCAL AND STATE CODES AND AUTHORITIES HAVING JURISDICTION. 2. PROVIDE CLEAN COMPACTED FILL FOR FOUNDATION BEARING. SOIL. SHALL BE COMPACTED "TO 98% MODIFIED PROCTOR MAXIMUM DRY DENSITY PER ASTM D 1557. PROVIDE COMPACTION AT A MINIMUM OF 24" BELOW BOTTOM OF FOUNDATION. TREAT SOIL FOR TERMITES. 3. PROVIDE STANDARD WEIGHT CONCRETE, 3000 PSI STRENGTH AT 28 DAYS WITH A WATER/CEMENT RATIO OF 0.58. REINFORCING SHALL BE GRADE 60 DEFORMED BARS. 4. PROVIDE STANDARD WEIGHT MASONRY 8 X 16 X 8. PROVIDE 9 GAGE HORIZONTAL JOINT REINFORCING AT 1a O.C. PROVIDE CONCRETE FILL AT BOND BEAMS AND FILLED CELLS WITH 2000 PSI STRENGTH AT 28 DAYS WITH COARSE AGGREGATE OF 318" MAXIMUM AND SLUMP OF 9 TO )'I INCHES. 5. PROVIDE PRE-ENGINEERED WOOD TRUSSES AS INDICATED. PROVIDE SHOP DRAWINGS SIGNED AND SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER. 6. PROVIDE ASPHALT SHINGLES, (20 YEAR WARRANTY), ON 15# ROOFING FELT. PROVIDE INSTALLATION IN ACCORDANCE WITH THE LOCAL AND STATE CODES. 7. PROVIDE A HOLLOW METAL DOOR AND FRAME AS FOLLOWS". A. 2" X o', 12 GAGE, GALVANIZED HOLLOW METAL FRAME WITH THREE JAMB ANCHORS PER SIDE AND GROUT FILL. PROVIDE PREP. FOR SPECIFIED HARDWARE. B. 1 3/4', 14 GAGE, GALVANIZED HOLLOW METAL- DOOR WITH INSULATED CORE. PROVIDE FLUSH TOP AND PREPARATION FOR SPECIFIED HARDWARE. C. HARDWARE 1 1/2° PAIR BUTTS: STANLEY FBB191 5 X 4 1/2 NRP US32D LOCKSET: SCHLAGE, STOREROOM LOCK - D80PN, ORBIT, US26D LOCK PROTECTOR: GLYNN-JOHNSON LP3 OVERHEAD DOOR STOP/HOLDER: GLYNN--JOHNSON GJ77M RAIN GUARD: PEMKO 346C THRESHOLD: PEMKO 159AS W/S2 DOOR BOTTOM: PEMKO 216AV SILENCER: GLYNN-JOHNSON G•J64 WEATHERSTRIPPING: PEMKO 306AV 8. PROVIDE PAINT FINISH BY SHERWIN WILLIAMS AS FOLLOWS: MASONRY: PRIME COAT - PRO MAR BLOCK FILLER 10 MILS DFT FINISH COAT (2) - PRO MAR A-100 FLAT LATEX HOME & TRIM 1.3 MILS DFT/COAT METAL DOOR AND FRAME: PRIME COAT -- GALVITE PAINT TOUCH --UP FINISH COAT (2) - METALISTIC 11 ENAMEL 3.0 MILS DFT/COAT WOOD SIDING: PRIME COAT - A-100 ALKYD EXTERIOR WOOD PRIMER 2.2 MILS DFT FINISH COAT (2) - A-100 SATIN LATEX HOUSE & TRIM 1.5 MILS OFT/COAT T1- I 1 EXTERIOR PLYWO ' SHEATHING I 0 GABEL ENDS - PROVIDE PAINT FINISH ELEVATION r- V-5'; OVERHANG - PRE -CAST CONC. LINTEL WITH GROUT FILL & 1 #5 - - - 3'-6' X 7'-0" HOLLOW METAL. DOOR .S'- 10" X 7,- 4" HOLLOW METAL DOOR FRAME - GROUT SOLID ASPHALT SHINGLES ON 1511 ROOFING FELT ON 5/8" CDX PL'AYOOD SHEATHING ALU,,1. RIDGE VENT 9n OVERHANG - 7- - _ .. :. PROVIDE BLOCK FILLER & 2 COArS - EXTERIOR ACRYLIC LATEX PAINT - TYP. T APPROX. LOCATION OF FINISHED GRADE I rELEVATION ----------1 /n„ =l'- 0„ SERVICE s AND PROVIDE INSULATING FOAM FILLER OR LOOSE PERLITE INSULATION IN PROVIDE 1' 4" X ?_ BLOCK-OUT INSTALL ALL NON-STRUCTURAL MASONRY CELLS 3 ROWS OF (4 - DIA. - WEATHER HEADSCH: 40 PVC - GROUT - 2.2'-0' INTO PLACE 2'_3" - I � } 3 (i(� J' L{ ALUM. SOFFIT- - - F ELECTRICAL PANEL T1-11 PLYWOOD I - - CABLE -TRAY SIDING L_ I v �- PHONE PANEL -/'-6' A.F.F '. i `'' -- -- -- -- ---- � ---- '. ---i - - $- �. T�t�lk K HOUSE_ 100 WATT FLOOD I I F l I— I I I WRAP 0 CABLE. LIGHTS WITH MOTION ' - - --- I ' I ENDS DETECTOR `. 1,a" C4. SB WITH 6 X 61'r'd1. X W1.4 ' I r 'r'WF ON 6 41L V066 BARRIER , '.- g... - - j> --- 'f - -._. j_ -. _. , .. ... ',_ ..- - -- - — _ I _r-_-• °�.. Re _- �F..itr--��r--,cis'__ �__. _<'t_ -r ._`xz;`-.y`=t.Zz! -- MONOLIjHIC �=OOTIN� .I'-4" 2'j (f # its -' ► WITH 3 #5') CONT. s # C OSS i I BARS �0, r r� I � j-- J LOAD BIE_ARI G MASONR', WAI[LSITH I I '" r-- -------- HORIZ IJT.EINF. 10 , 0. �t�FILLED / I CELLS ']PITH 151 #5 9 4'-0" �).0 MAX. LJ ~= t—_� PROVIDE 1'- X 2'- --- ROV 4" � ., kLLc9LO(.,K--0UT - IN' TALL - 3 ROWS OF (4) - 4" DIA. J� I SCH: 40 PVC - GROUT 1 1rt_1 CABLE TRAY INTO PLACE 1,L , 7'-6' A F F � FLOOR/FOUNDATIN PLAN 7m' 2 X 6 WOOD FASCIA CONT. 0 PERIM. PRE-ENGINEERED WOOD TRUSSES 0 24" O.C. WITH 16 GAGE STEEL BEARING PLATES AND SIMPSON HETA12 - HURRICANE ANCHORS EACH END. LOAD BEARING MASONRY WALL 5/8" CDX PLYWOOD SHEATHING WITH 8 d NAILS 0 6' O.C. @ PERIM. 3c 12° O.C. IN THE FIELD 2 X 4 STUD BRACE 0 TOP CHORD OF GABLE TRUSSES ROOFLOADS TOP CHORD: LIVE LOAD 20 PSF DEAD LOAD 20 PSF BOTTOM CHORD: DEAD LOAD 20 PSF i I-- ROOFPLAN_ I GROUT CELLS BELO+'d 1 KNOCK -OUT " =1 1 "1 ter, I SEE SECTION 'B' ' FOR MATERIAL - NOTES AND DETAILS { a � 1 t '1 I ,lei _ I— _{ lj1 2'-Y' "\, WALL SECTION PROVIDE V-4" X 2'--0n BLOCK-OUT - INSTALL 3 ROWS OF (4) - 4" DIA. SCH: 40 PVC - GROUT INTO PLACE r1- I 'I EXTERIOR PLYWOOD SHEATHING ` 0GABEL ENDS - PROVIDE PAINT FINISH LE31, +7 BT IO �-------'----- A--1 1/4" -l' --(:P PRE-ENGINEERED WOOD TRUSSES 12 24" OC. WITH HURRICANE f(� STRAPS 4 EACH TRUSS 41 -- ASPHALT SHINGLES ON 15# ROOFING r ELT ON 5/8" CDX "r f PLYWOOD SHEATHING -- IYP. ALUM. DRIP (,oNT. r r �--) a" BAFi INSUI1TIf)N <0 PERIM. , (P. �r1 V-6" I I I I 5/8" PLYWOOD t , 3 A I SHEA11-IING - TYP. ALUMINUM TA.JCIA ON I i DOUE3l F POND SEAM: WOOD BLOCKINGi� `=1 ?-COURSES KNOCK -OUT CONT. @ PERIM. 1- BLOCK WITH 2#5's EA- E COURSE AND CONC. FILL VENTILATED ALUM. SOFFIT�r-i CONT. @ PERIM. 1 k GROUT SCREEN CONT. BOTT, OF BOND BEAM. 8x8.<16 NORMAL WT_ CONC. [ PROVIDE INSULATING FOAM BLOCK W11H HORIZ. JT. REINF. i FILLER OR LOOSE PERLITE @ 16' OC - TYP. STRIKE S r - INSULATION IN ALL NON - r ? STRUCTURAL MASONRY CELLS rIURIZ. MORTAR JOIPITS -- 'TROWEL1 VERT. JOINTS SMOOTH - TYP. 1 I o I I FILLED CELLS WITH 1#5 AS INDICATED IN PLAN - TYPF 1- #5 DOWELS AS INDICATED IN PLAN WITH MIN. 24" LAP AND V-0" HOOK. I r SET FINISH FLOOR 0 4" ABOVE GRADE. RECESS CONC. SLAB 1" N; so�Lj 4-" q