Loading...
HomeMy WebLinkAboutE24-000733 (Elec Plans.(APPROVED)SHEET CATALOG INDEX NO. DESCRIPTION E-01 COVER PAGE & SITE PLAN E-02 RISER DIAGRAM & PANEL SCHEDULE SCOPE OF WORK GENERAL SYSTEM INFORMATION: V CHARGER: (N)ELECTRIC VEHICLE CHARGER APPLICABLE CODES ELECTRIC CODE:NEC 2020 FIRE CODE:FFPC 2023 BUILDING CODE:FBC 2023 (8TH EDITION) RESIDENTIAL CODE: FRC 2023 GENERAL NOTES 1.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 2.WORKING CLEARANCES AROUND THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 3.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 4.ALL CONDUCTORS SHALL BE 60OV, 75'C STANDARD COPPER UNLESS OTHERWISE NOTED. 5. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 6.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. VICINITY MAP i o .... i i ,... i p i ALLISON VAN TILBORGH SITE PLAN LAYOUT ENGINEERING SCOPE OF WORK 1. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT DRAWINGS, HE/SHE: a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN C. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN CARLA ALVAREZ Notary Public - State of Florida Commission # HH 419754 My Comm. Expires Jul 10, 2027 (E) MAIN DISTRIBUTION PANEL (INTERIOR) (E) UTILITY METER WITH MAIN SERVICE PANEL (EXTERIOR) (N) ELECTRIC VEHICLE CHARGER (EXTERIOR) Any new or addition electrical work will require and additional electrical permit. GARAGE REVIEWED FOR COI SEAMWOODARD-PX3846 E COMPLTCl IANCE —724 DL �IyILD?`YG SANFORD c.1 111,A C.RREC-r CO —RUCTION OR — I,AjI 1 IONS CD T1 ID CODE OEPARTM4'�� SITE COPY I char a9 P ros LICENSE NO: EC13012690 CUSTOMER INFORMATION I NAME: ALLISON VAN TILBORGH ADDRESS: 719 WILLOW AVE, SANFORD, FL- 32771 28.805684624,-81.25840546 APN: 25-19-30-5AG-03OG-0100 PROJECT QUALIF ER: JAMES MUNGER AHJ:FL - SEMINOLE COVER PAGE SITE PLAN LAYOUT QC'ED BY: PAPER SIZE: 17"X11" RAY P. DATE:09/18/24 REV:A E-01 ELECTRICAL NOTES 1. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C). 2. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). 3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. S. BREAKER/FUSES SIZED ACCORDING PER NEC ARTICLE 240. 6. AC GROUNDING ELECTRODE CONDUCTOR (GEC) SIZED PER NEC 250.66. 7. EQUIPMENT GROUNDING CONDUCTOR (EGC) SIZED PER NEC 250.122, ARE CONNECTED TO RESPECTIVE PANEL GROUND BUSBARS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC 2020), ARTICLE 250 8. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(2). 9. CURRENT CARRYING CONDUCTOR ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(3). 10. MAX. SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7. 11. CONDUCTORS ARE SIZED PER WIRE AMPACITY NEC 310.15(B)(16). 12. ALL ELECTRICAL COMPONENTS OF THE DESIGN, SUCH AS, MATERIALS, EQUIPMENT, LIGHTING FIXTURES AND OTHERS MUST BE LISTED AND APPROVED FOR USE. THE TESTING OF THESE ELECTRICAL COMPONENTS MUST BE PERFORMED BY A RECOGNIZED AND QUALIFIED ELECTRICAL LABORATORY, IN ACCODANCE WITH NEC 110.3(C) 13. ALL INSTALLATIONS ARE IN COMPLIANCE WITH THE FOLLOWING CODES: FBC 107.3.5 (B), FBC R-314, NEC 2020 ART. 220.83 LEGEND �— OMEIt SEANCE EN1R m DESCPoPADN AS INgCATEO IN PLAN. OY.T. NEIFA, DEB[AIPAON AS WpCATED IN PLAN CIFICAL PAta>. —D. BCUIT BREAIfER. RATING AND TYPE AS IMMAIED IN PLANS. D BUSBM. -I - —ND SI—, NBB -NEUTRAL USBAR j D. DESCPoPApI AS MICA= IN PLAN pSCONNECT. DESCRIPl10N AS NgCATED RI PLAN RISER DIAGRAM AND PANEL SCHEDULE UTILITY GRID SERVICE PANEL SCHEDULE (MSP) VOLTAGE MAIN PHASETYPE LOCATION 120/240V 150A SINGLE PHASE GARAGE EXTERIOR LOAD DESCRIPTION CB CKT NO. CKT NO. CB LOAD DESCRIPTION 1 2 ovA ELECT RIC VEHICLE CHARGER 3 4 5 6 7 8 EXISTING :EVIEWED OR CODE COMPLIANCEe Ian2,age roxrx rxe°raPolnvONSOeTHETeOwatcAiAR17B-cO-CIA�nom TH—eseAeT�e SITE qOPY E24-000733 Vh %�►RY °,0, CARLA AREZ ®+ Notary Public - State of Florida LICE '= Commission # HH 419754 CUST My Comm. Expires Jul 10, 2027 NAME: A MSP MDP (N) ELECTRIC VEHICLE NOTES: (N)—NEW (E)1201240V CHARGER (E)—EXISTING 1 PH kWhr METER WITH 150A MAIN (EXTERIOR) SERVICE PANEL (HARDWIRED) (EXTERIOR) t150A WITH BUILT IN A GFCI PROTECTION (E)INTERBONDING 40-48" MOUNTING HEIGHT (E)MAIN DISTRIBUTION SYSTEM PANEL (INTERIOR) (E) (1) #6 AWG COPPER WIRE, GEC , (N) (2) #6 AWG THHNITHWN-2 (Cu) + 10' DEEP GROUNDING ROD s/" DIA (1) #10 AWG CONDUIT (Cu) ( ) IN /" PVC CONDUIT GRADE C argepros NSE NO: EC13012690 OMER INFORMATION I LLISON VAN TILBORGH ADDRESS: 719 WILLOW AVE, SANFORD, FL- 32771 28.805684624,-81.25840546 APN: 25-19-30-5AG--)\Cy 03OGG-0100 PROJECT QUALI IER: JAMES MUNGER AHJ:FL - SEMINOLE RISER DIAGRAM AND PANEL SCHEDULE QCED BY: PAPER SIZE: 17"XI I" RAY P. DATE:09/18/24 REV:A E-02