HomeMy WebLinkAboutE24-000733 (Elec Plans.(APPROVED)SHEET CATALOG
INDEX NO. DESCRIPTION
E-01 COVER PAGE & SITE PLAN
E-02 RISER DIAGRAM & PANEL
SCHEDULE
SCOPE OF WORK
GENERAL SYSTEM INFORMATION:
V CHARGER:
(N)ELECTRIC VEHICLE CHARGER
APPLICABLE CODES
ELECTRIC CODE:NEC 2020
FIRE CODE:FFPC 2023
BUILDING CODE:FBC 2023 (8TH EDITION)
RESIDENTIAL CODE: FRC 2023
GENERAL NOTES
1.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
2.WORKING CLEARANCES AROUND THE NEW
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH NEC 110.26.
3.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
4.ALL CONDUCTORS SHALL BE 60OV, 75'C
STANDARD COPPER UNLESS OTHERWISE NOTED.
5. WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
6.THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
VICINITY MAP
i
o .... i i ,...
i p
i
ALLISON VAN TILBORGH
SITE PLAN LAYOUT
ENGINEERING SCOPE OF WORK
1. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT
DRAWINGS, HE/SHE:
a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN
b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN
C. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN
CARLA ALVAREZ
Notary Public - State of Florida
Commission # HH 419754
My Comm. Expires Jul 10, 2027
(E) MAIN DISTRIBUTION
PANEL (INTERIOR)
(E) UTILITY METER WITH MAIN
SERVICE PANEL (EXTERIOR)
(N) ELECTRIC VEHICLE
CHARGER (EXTERIOR)
Any new or addition electrical work will
require and additional electrical permit.
GARAGE
REVIEWED FOR COI
SEAMWOODARD-PX3846
E COMPLTCl IANCE
—724
DL
�IyILD?`YG
SANFORD
c.1 111,A C.RREC-r
CO —RUCTION OR —
I,AjI
1
IONS CD T1 ID CODE
OEPARTM4'��
SITE COPY I
char a9 P ros
LICENSE NO: EC13012690
CUSTOMER INFORMATION I
NAME: ALLISON VAN TILBORGH
ADDRESS: 719 WILLOW AVE, SANFORD,
FL- 32771
28.805684624,-81.25840546
APN: 25-19-30-5AG-03OG-0100
PROJECT QUALIF ER: JAMES MUNGER
AHJ:FL - SEMINOLE
COVER PAGE
SITE PLAN LAYOUT
QC'ED BY: PAPER SIZE: 17"X11"
RAY P.
DATE:09/18/24 REV:A
E-01
ELECTRICAL NOTES
1. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE
IN WET LOCATIONS PER NEC 310.10(C).
2. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT
RESISTANT PER NEC 310.10(D).
3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%.
4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED.
S. BREAKER/FUSES SIZED ACCORDING PER NEC ARTICLE 240.
6. AC GROUNDING ELECTRODE CONDUCTOR (GEC) SIZED PER NEC 250.66.
7. EQUIPMENT GROUNDING CONDUCTOR (EGC) SIZED PER NEC 250.122,
ARE CONNECTED TO RESPECTIVE PANEL GROUND BUSBARS IN ACCORDANCE
WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC 2020),
ARTICLE 250
8. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON
NEC 310.15(B)(2).
9. CURRENT CARRYING CONDUCTOR ADJUSTMENT FACTOR IS BASED ON NEC
310.15(B)(3).
10. MAX. SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7.
11. CONDUCTORS ARE SIZED PER WIRE AMPACITY NEC 310.15(B)(16).
12. ALL ELECTRICAL COMPONENTS OF THE DESIGN, SUCH AS, MATERIALS,
EQUIPMENT, LIGHTING FIXTURES AND OTHERS MUST BE LISTED AND
APPROVED FOR USE. THE TESTING OF THESE ELECTRICAL COMPONENTS
MUST BE PERFORMED BY A RECOGNIZED AND QUALIFIED ELECTRICAL
LABORATORY, IN ACCODANCE WITH NEC 110.3(C)
13. ALL INSTALLATIONS ARE IN COMPLIANCE WITH THE FOLLOWING CODES:
FBC 107.3.5 (B), FBC R-314, NEC 2020 ART. 220.83
LEGEND
�—
OMEIt SEANCE EN1R m DESCPoPADN AS INgCATEO IN PLAN.
OY.T.
NEIFA, DEB[AIPAON AS WpCATED IN PLAN
CIFICAL PAta>. —D.
BCUIT BREAIfER. RATING AND TYPE AS IMMAIED IN PLANS.
D BUSBM. -I - —ND SI—, NBB -NEUTRAL
USBAR
j
D. DESCPoPApI AS MICA= IN PLAN
pSCONNECT. DESCRIPl10N AS NgCATED RI PLAN
RISER DIAGRAM AND PANEL SCHEDULE
UTILITY GRID SERVICE
PANEL SCHEDULE (MSP)
VOLTAGE
MAIN
PHASETYPE
LOCATION
120/240V
150A
SINGLE PHASE
GARAGE EXTERIOR
LOAD DESCRIPTION
CB
CKT NO.
CKT NO.
CB
LOAD DESCRIPTION
1
2
ovA
ELECT RIC VEHICLE CHARGER
3
4
5
6
7
8
EXISTING
:EVIEWED OR CODE COMPLIANCEe
Ian2,age roxrx rxe°raPolnvONSOeTHETeOwatcAiAR17B-cO-CIA�nom TH—eseAeT�e
SITE qOPY E24-000733
Vh
%�►RY °,0, CARLA AREZ
®+ Notary Public - State of Florida LICE
'= Commission # HH 419754 CUST
My Comm. Expires Jul 10, 2027 NAME: A
MSP MDP
(N) ELECTRIC VEHICLE
NOTES: (N)—NEW (E)1201240V CHARGER
(E)—EXISTING 1 PH kWhr METER
WITH 150A MAIN (EXTERIOR)
SERVICE PANEL (HARDWIRED)
(EXTERIOR) t150A WITH BUILT IN
A GFCI PROTECTION
(E)INTERBONDING 40-48" MOUNTING HEIGHT (E)MAIN DISTRIBUTION
SYSTEM PANEL (INTERIOR)
(E) (1) #6 AWG COPPER WIRE, GEC , (N) (2) #6 AWG THHNITHWN-2 (Cu) +
10' DEEP GROUNDING ROD s/" DIA (1) #10 AWG CONDUIT
(Cu)
( ) IN /" PVC CONDUIT
GRADE
C
argepros
NSE NO: EC13012690
OMER INFORMATION I
LLISON VAN TILBORGH
ADDRESS: 719 WILLOW AVE, SANFORD,
FL- 32771
28.805684624,-81.25840546
APN: 25-19-30-5AG--)\Cy
03OGG-0100
PROJECT QUALI IER: JAMES MUNGER
AHJ:FL - SEMINOLE
RISER DIAGRAM AND PANEL
SCHEDULE
QCED BY: PAPER SIZE: 17"XI I"
RAY P.
DATE:09/18/24 REV:A