HomeMy WebLinkAboutREVIEW COMPLETE - Energy Calcs Main House 1101 Palmetto AveFORM R405-2023 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2023 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2023 report Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed 2023 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2023 Duct Leakage Test Report - Performance Method (usually one page) . 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 of 1 FORM R405-2023 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hubbell Residence-ENB Builder Name: Street:1101 PALMETTO AVE Permit Office: City, State, Zip: SANFORD, FL, 32771 Permit Number: Owner:KC CONSTRUCTION Jurisdiction: Design Location: FL, Orlando County: seminole(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)2446 Conditioned floor area below grade (ft²)0 7. Windows(270.9 sqft.) Description Area a. U-Factor:Dbl, U=0.35 270.90 ft2 S H G C :SHGC=0.29 b. U-Factor:N/A f t2 S H G C : c. U-Factor:N/A f t2 S H G C : Area Weighted Average Overhang Depth: 2.329 ft Area Weighted Average SHGC:0.290 8. Skylights Description Area U - F a c t o r : ( A V G ) N/A N/A ft2 S H G C ( A V G ) : N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1685.00 f t2 b. Floor Over Other Space R= 0.0 761.00 f t2 c. N/A R = f t2 10. Wall Types(4618.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Ext Insul, Exterior R=4.1 3806.00 ft2 b. Frame - Wood, Exterior R=19.0 812.00 ft2 c. N/A d. N/A 11. Ceiling Types(1756.0 sqft.) I n s u l a t i o n Area a. Flat ceiling under att (Vented) R=30.0 1756.00 ft2 b. N/A c. N/A 12. Roof(Comp. Shingles, Vented) Deck R=0.0 1962 ft2 13. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 178 b . c . 14. Cooling Systems k B t u / h r Efficiency a. Central Unit 40.0 SEER2:14.30 15. Heating Systems k B t u / h r Efficiency a. Electric Heat Pump 42.0 HSPF2:7.50 16. Hot Water Systems a. Electric Cap: 50 gallons EF: 0.900 b. Conservation features None 17. Credits Pstat Glass/Floor Area:0.111 Total Proposed Modified Loads: 77.92 Total Baseline Loads: 88.82 PASS NOTE: Proposed residence must have annual total normalized Modified Loads that are less than or equal to 95 percent of the annual total loads of the standard reference design in order to comply. I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code.calculation indicates compliance with the Florida Energy Code. PREPARED BY: _________________________________ Before construction is completed this building will be inspected for DATE: _________________________________________ compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________ DATE: _________________________________________ DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Default duct leakage does not require a Duct Leakage Test Report. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 5/20/24 FORM R405-2023 INPUT SUMMARY CHECKLIST REPORT PROJECT Title:Hubbell Residence-ENB Address type:Street Address Building Type:Bedrooms:Lot #:User 3 --- Owner:Conditioned Area:Block/SubDivision:KC CONSTRUCTION 2446 --- Builder Home ID:Total Stories:PlatBook:2 --- Builder Name:Worst Case:Street:No 1101 PALMETTO AVE Permit Office:Rotate Angle:County:0 seminole Jurisdiction:Cross Ventilation:City, State, Zip:No SANFORD, Family Type:Whole House Fan: Detached No FL, 32771 New/Existing:Terrain: New (From Plans)Suburban Year Construct:Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range ___ FL, Orlando FL_ORLANDO_INTL_ARPT 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume ___ 1 Entire House 2446 21927 cu ft SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 2nd Floor 761 6088 No 1 1 Yes Yes Yes ___ 2 1st Floor 1685 15839 Yes 3 2 Yes Yes Yes FLOORS (Total Exposed Area = 1685 sq.ft.) #Floor Type Space Exposed Area R-Value U-Factor Slab Insul.Tile Wood Carpet Perim(ft)Perim. Joist Vert/Horiz ___ 1 Floor Over Other Space 2nd Floor ---761 sqft ---0.172 -------0.00 0.00 1.00 ___ 2 Slab-On-Grade Edge Ins 1st Floor 1685 sqft ---0.566 0 (ft)/0 (ft)0.29 0.00 0.71 ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch #Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg) ___ 1 Hip Composition shingles 1962 ft²0 ft²Medium N 0.7 No 0.9 No 0 26.57 ATTIC #Type Ventilation Vent Ratio (1 in)Area RBS IRCC ___ 1 Full attic Vented 300 1755 ft²N N 5/20/2024 1:30:19 PM Page 2EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software FORM R405-2023 INPUT SUMMARY CHECKLIST REPORT CEILING (Total Exposed Area = 1756 sq.ft.) #Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type ___ 1 Flat ceiling under attic(Vented)2nd Floor 30.0 Blown 1283.0ft²0.053 0.10 Wood ___ 2 Flat ceiling under attic(Vented)1st Floor 30.0 Blown 473.0ft²0.053 0.10 Wood WALLS (Total Exposed Area = 4618 sq.ft.) Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below #Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade ___ 1 N Exterior Frame - Wood 2nd Floor 19.0 27.0 0 8.0 0 216.0 0.072 0 0.25 0.45 0 % ___ 2 E Exterior Frame - Wood 2nd Floor 19.0 32.0 6 8.0 0 260.0 0.072 0 0.25 0.45 0 % ___ 3 S Exterior Frame - Wood 2nd Floor 19.0 27.0 0 8.0 0 216.0 0.072 0 0.25 0.45 0 % ___ 4 W Exterior Frame - Wood 2nd Floor 19.0 15.0 0 8.0 0 120.0 0.072 0 0.25 0.45 0 % ___ 5 N Exterior Conc. Blk - Ext Ins 1st Floor 4.1 54.0 0 22.0 0 1188.0 0.131 0 0 0.45 0 % ___ 6 E Exterior Conc. Blk - Ext Ins 1st Floor 4.1 32.0 6 22.0 0 715.0 0.131 0 0 0.45 0 % ___ 7 S Exterior Conc. Blk - Ext Ins 1st Floor 4.1 54.0 0 22.0 0 1188.0 0.131 0 0 0.45 0 % ___ 8 W Exterior Conc. Blk - Ext Ins 1st Floor 4.1 32.0 6 22.0 0 715.0 0.131 0 0 0.45 0 % DOORS (Total Exposed Area = 72 sq.ft.) Width Height #Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 E Wood 1st Floor None 0.39 3.00 0 8.00 0 24.0ft² ___ 2 W Wood 1st Floor None 0.39 6.00 0 8.00 0 48.0ft² WINDOWS (Total Exposed Area = 271 sq.ft.) Wall Total Same Width Height --Overhang-- #Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Units (ft)(ft)Depth Sep.Interior Shade Screen (ft²)(ft)(ft) ___ 1 E 2 Vinyl Double (Clear)Y 0.35 0.29 N N 12.0 1 3.00 4.00 1.0 1.0 None Ex. 50% ___ 2 W 4 Vinyl Double (Clear)Y 0.35 0.29 N N 14.5 1 3.00 4.83 1.0 1.0 None Ex. 50% ___ 3 N 5 Vinyl Double (Clear)Y 0.35 0.29 N N 12.0 1 3.00 4.00 1.0 1.0 None Ex. 50% ___ 4 N 5 Vinyl Double (Clear)Y 0.35 0.29 N N 16.0 1 4.00 4.00 1.0 1.0 None Ex. 50% ___ 5 E 6 Vinyl Double (Clear)Y 0.35 0.29 N N 72.0 4 3.00 6.00 6.0 1.0 None Ex. 50% ___ 6 S 7 Vinyl Double (Clear)Y 0.35 0.29 N N 12.8 1 3.08 4.17 1.0 1.0 None Ex. 50% ___ 7 S 7 Vinyl Double (Clear)Y 0.35 0.29 N N 98.7 6 3.08 5.33 1.0 1.0 None Ex. 50% ___ 8 W 8 Vinyl Double (Clear)Y 0.35 0.29 N N 32.9 2 3.08 5.33 1.0 1.0 None Ex. 50% INFILTRATION #Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)Infiltration Test Volume ___ 1 Wholehouse Proposed ACH(50)0.00040 2558 140.35 263.49 0.1944 7.0 21927 cu ftAll GARAGE #Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ___ 1 542 ft²542 ft²64 ft 9 ft 1 5/20/2024 1:30:19 PM Page 3EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software FORM R405-2023 INPUT SUMMARY CHECKLIST REPORT MASS #Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 2nd Floor ___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 1st Floor HEATING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Heat Pump Split/Single HSPF2: 7.50 42.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit Split/Single SEER2:14.3 40.0 0 0.75 sys#1 1 HOT WATER SYSTEM #System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length ___ 1 Electric None Garage 0.90 (0.91)50.00 gal 61 gal 120 deg Standard None 98 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct --------------Supply----------------------------Return--------------Air CFM 25 CFM 25 HVAC # #Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 Attic 6.0 178 ft²Attic 6.0 49 ft²Default Leakage 2nd Floor (Default)(Default)1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80PM808078787878787878787878 ___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 ___ Heating (WD)AM 66 66 66 66 66 68 68 68 68 68 68 68PM686868686868686868686666 ___ Heating (WEH)AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 4 FORM R405-2023 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the EnergyPerformance Index, the more efficient the home. 1101 PALMETTO AVE,SANFORD,FL,32771 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)2446 Conditioned floor area below grade (ft²)0 7. Windows**Description Area a. U-Factor:Dbl, U=0.35 270.90 ft2 S H G C :SHGC=0.29 b. U-Factor:N/A f t2 S H G C : c. U-Factor:N/A f t2 S H G C : Area Weighted Average Overhang Depth:2.329 ft Area Weighted Average SHGC:0.290 8. Skylights Description Area U - F a c t o r : ( A V G )N/A N/A ft2 S H G C ( A V G ) :N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1685.00 f t2 b. Floor Over Other Space R= 0.0 761.00 f t2 c. N/A R = f t2 10. Wall Types(4618.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Ext Insul, Exterior R=4.1 3806.00 ft2 b. Frame - Wood, Exterior R=19.0 812.00 ft2 c. N/A d. N/A 11. Ceiling Types(1756.0 sqft.) I n s u l a t i o n Area a. Flat ceiling under att (Vented)R=30.0 1756.00 ft2 b. N/A c. N/A 12. Roof(Comp. Shingles, Vented)Deck R=0.0 1962 ft2 13. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 178 b . c . 14. Cooling Systems k B t u / h r Efficiency a. Central Unit 40.0 SEER2:14.30 15. Heating Systems k B t u / h r Efficiency a. Electric Heat Pump 42.0 HSPF2:7.50 16. Hot Water Systems a. Electric Cap: 50 gallons EF: 0.900 b. Conservation features None 17. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ___________________________________Date: _________________________ Address of New Home: 1101 PALMETTO AVE City/FL Zip: SANFORD,FL,32771 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 8th Edition (2023) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS:1101 PALMETTO AVE Permit Number: SANFORD, FL 32771 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card - (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE R402.2.10.1 Slab-on-grade floor insulation installation (Mandatory). Where installed, the insulation shall extend downward from the top of the slab on the outside or inside of the foundation wall. Insulation located below grade shall be extended the distance provided in Table R402.1.2, or the distance of the proposed design as applicable, by any combination of vertical insulation, insulation extending under the slab or insulation extending out from the building. Insulation extending away from the building shall be protected by pavement or by not less than 10 inches (254 mm) of soil. The top edge of the insulation installed between the exterior wall and the edge of the interior slab shall be permitted to be cut at a 45-degree (0.79 rad) angle away from the exterior wall. R402.2.11.1 Crawl space walls insulation installation (Mandatory). Where crawl space wall insulation is installed, it shall be permanently fastened to the wall and extend downward from the floor to the finished grade level and then vertically and/or horizontally for at least an additional 24 inches (610 mm). Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder in accordance with the Florida Building Code, Building, or Florida Building Code, Residential, as applicable. All joints of the vapor retarder shall overlap by 6 inches (153 mm) and be sealed or taped. The edges of the vapor retarder shall extend not less than 6 inches (153 mm) up the stem wall and shall be attached to the stem wall. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. E x c e p t i o n : Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer’s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Dwelling units with an air leakage rate less than three air changes per hour shall be provided with whole-house mechanical ventilation in accordance with Section R403.6.1 of this code and Section M1507.3 of the Florida Building Code, Residential. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. E x c e p t i o n : Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. 7. If an attic is both air sealed and insulated at the roof deck, interior access doors and hatches between the conditioned space volume and the attic shall be opened during the test and the volume of the attic shall be added to the conditioned space volume for purposes of reporting an infiltration volume and calculating the air leakage of the home. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. E x c e p t i o n : Site-built windows, skylights and doors. R402.4.4 Rooms containing fuel - burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R402.4.6 Air-sealed electrical and communication boxes. Air-sealed electrical and communication boxes that penetrate the air barrier of the building thermal envelope shall be caulked, taped, gasketed, or otherwise sealed to the air barrier element being penetrated. Air-sealed boxes shall be buried in or surrounded by insulation. Air-sealed boxes shall be marked in accordance with NEMA OS 4. Air-sealed boxes shall be installed in accordance with the manufacturer's instructions. SECTION R403 SYSTEMS R403.1 Controls R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps with supplementary electric-resistance heaters shall have controls that limit supplemental heat operation to only those times when one of the following applies: 1. The vapor compression cycle cannot provide the necessary heating energy to satisfy the thermostat setting. 2. The heat pump is operating in defrost mode. 3. The vapor compression cycle malfunctions. 4. The thermostat malfunctions R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be “substantially leak free” in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2 Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. E x c e p t i o n s ; 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 2 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. R403.5.2 Demand recirculation water systems (Mandatory). Where installed, demand recirculation water systems shall have controls that comply with both of the following: 1. The control shall start the pump upon receiving a signal from the action of a user of a fixture or appliance, sensing the presence of a user of a fixture or sensing the flow of hot or tempered water to a fixture fitting or appliance. 2. The control shall limit the temperature of the water entering the cold water piping to 104ºF (40ºC). R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 ½ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 3 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. E x c e p t i o n : Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACYa AIRFLOW RATE MAXIMUM (CFM)(CFM/WATT)(CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In-line fan Any 3.8 cfm/watt Any Bathroom, utility room 10 2.8 cfm/watt <90 Bathroom, utility room 90 3.5 cfm/watt Any For SI: 1 cfm = 28.3 L/min.a. When tested in accordance with HVI Standard 916 R403.6.2 Ventilation Air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 4 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). 403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste-heat-recovery pool heating systems 3. Where pumps are powered exclusively from on-site renewable generation. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 5 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception:Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recovered energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required R403.10.4 Gas- and oil-fired pool and spa heaters. All gas- and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14 R403.13 Dehumidifiers (Mandatory). If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). All permanently installed luminaires, excluding those in kitchen appliances, shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 6 of 7 Florida Building Code, Energy Conservation, Mandatory Requirements (2023 Continued) SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) R405.2 Mandatory requirements. Compliance with this section requires that the mandatory provisions identified in Section R401.2 be met. All supply and return ducts not completely inside the building thermal envelope shall be insulated to a minimum of R-6, except site-wrapped supply ducts not completely inside the building thermal envelope shall be insulated to a minimum of R-8. R405.2.1 Ceiling insulation. Ceilings shall have an insulation level of at least R-19, space permitting. For the purposes of this code, types of ceiling construction that are considered to have inadequate space to install R-19 include single assembly ceilings of the exposed deck and beam type and concrete deck roofs. Such ceiling assemblies shall be insulated to at least a level of R-10. R405.2.2 Building air leakage testing. Building or dwelling air leakage testing shall be in accordance with Sections R402.4 through R402.4.1.2. If an air leakage rate below seven air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) is specified for the proposed design, testing shall verify the air leakage rate does not exceed the air leakage rate of the proposed design instead of seven air changes per hour. R405.2.3 Duct air leakage testing. In cases where duct air leakage lower than the default Qn to outside of 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is specified for the proposed design, testing in accordance with Section R403.3.2 shall verify a duct air leakage rate not exceeding the leakage rate of the proposed design. Otherwise, in accordance with Section R403.3.3, duct testing is not mandatory for buildings complying by Section R405. SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE R406.2 Mandatory requirements. Compliance with this section requires that the provisions identified in Sections R401 through R404 labeled as “mandatory” and Section R403.5.3 of the 2015 International Energy Conservation Code be met. For buildings that do not utilize on-site renewable power production for compliance with this section, the building thermal envelope shall be greater than or equal to levels of efficiency and Solar Heat Gain Coefficient in Table 402.1.1 or 402.1.3 of the 2009 International Energy Conservation Code. For buildings that utilize on-site renewable power production for compliance with this section, the building thermal envelope shall be greater than or equal to levels of efficiency and Solar Heat Gain Coefficient in Table R402.1.2 or Table R402.1.4 of the 2015 International Energy Conservation Code. E x c e p t i o n : Supply and return ducts not completely inside the building thermal envelope shall be insulated to a minimum of R-6. R406.2.1 Site-wrapped supply ducts. Site-wrapped supply ducts not completely inside the building thermal envelope shall be insulated to a minimum of R-8. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 7 of 7 CHECK2023 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA-TABLE 402.4.1.1a Project Name:Hubbell Residence-ENB Builder Name: Street:1101 PALMETTO AVE Permit Office: City, State, Zip:SANFORD, FL, 32771 Permit Number: Owner:KC CONSTRUCTION Jurisdiction: Design Location:FL, Orlando County:seminole(Florida Climate Zone 2) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed.a material having a thermal resistance of R-3 per Knee walls shall be sealed.inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation.maintain permanent contact with the underside of above-garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs.be insulated. Boxes, housings, and enclosures that penetrate the air barrier Boxes, housings, and enclosures shall be buried in shall be caulked, taped, gasketed, or otherwise sealed or surrounded by tightly fitted insulation. Electrical,to the air barrier element being penetrated. communication, and All concealed openings into the box, housing, or enclosure other equipment shall be sealed. boxes, housings, The continuity of the air barrier shall be maintained around and enclosures boxes, housings, and enclosures that penetrate the air barrier. Alternatively, air-sealed boxes shall be installed in accordance with R402.4.6 HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2023 Florida Building Code, Energy Conservation, 8th Edition Jurisdiction:Permit #: Job Information Builder:Community:Lot:NA Address:1101 PALMETTO AVE City:SANFORD State:FL Zip:32771 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2023 (Performance) or R406-2023 (ERI), section labeled as infiltration, sub-section ACH50. ACH(50) specified on Form R405-2023-Energy Calc (Performance) or R406-2023 (ERI):7.000 _________ x 60 ÷ ______________ = ____________21927 CFM(50) Building Volume ACH(50) PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume:_____________________________ Retrieved from architectural plans Code software calculated Field measured and calculated R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Dwelling units with an air leakage rate less than three air changes per hour shall be provided with whole-house mechanical ventilation in accordance with Section R403.6.1 of this code and Section M1507.3 if the Florida Building Code, Residential. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control m e a s u r e s . 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. 7. If an attic is both sealed and insulated at the roof deck, interior access doors and hatches between the conditioned space volume and the attic shall be opened during the test and the volume of the attic shall be added to the conditioned space volume for purposes of reporting the infiltration volume and calculating the air leakage of the home. Testing Company Company Name: ______________________________________Phone: ________________________ I hereby verify that the above Air Leakage results are in accordance with the 2023 8th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________Date of Test: ______________________ Printed Name of Tester: _________________________________ License/Certification #: _____________________________Issuing Authority: _________________________ 5/20/2024 1:30:19 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 of 1 2024-May-20 12:08:07 Right-Suite® Universal 2024 24.0.01 RSU62060 Page 1 ...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Manual S Compliance Report 01/23Date:Entire House JNBy: Strada Services Project Information KC CONSTRUCTIONFor: 1101 PALMETTO AVE, SANFORD, FL 32771 Cooling Equipment Design Conditions °F76.3Entering coil DB:Btuh29508Sensible gain:°F92.9Outdoor design DB: °F63.0Entering coil WB:Btuh3700Latent gain:°F75.8Outdoor design WB: Btuh33208Total gain:°F75.0Indoor design DB: cfm1333Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GH5SAN44200AA0+FJ4DNXC42LModel:CarrierManufacturer: cfm1333Actual airflow: % of load108Btuh31806Sensible capacity: % of load156Btuh5756Latent capacity: %85SHR:% of load113Btuh37562Total capacity: Heating Equipment Design Conditions °F67.6Entering coil DB:Btuh28599Heat loss:°F41.3Outdoor design DB: °F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GH5SAN44200AA0+FJ4DNXC42LModel:CarrierManufacturer: cfm1333Actual airflow: °F32Capacity balance:% of load142Btuh40504Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm1333Actual airflow: °F153Temp. rise:% of load75kW6.3Output capacity: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 1...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Project Summary 01/23Date:Entire House JNBy: Strada Services Project Information KC CONSTRUCTIONFor:1101 PALMETTO AVE, SANFORD, FL 32771 Notes: Design Information Orlando Sanford, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F93Inside db °F68 Inside db °F75Design TD °F27 Design TD °F18Daily range MRelative humidity %50Ventilation Method MJ8 Moisture difference gr/lb42 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh24934 Structure Btuh23124Ducts (R-6.0)Btuh1935 Ducts (R-6.0)Btuh3579Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0PipingBtuh0Equipment load Btuh26869 Use manufacturer's data nRate/swing multiplier 0.98InfiltrationEquipment sensible load Btuh26142 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh3532DuctsBtuh152Central vent (0 cfm)Btuh0CoolingHeating30383038Area (ft²)Equipment latent load Btuh36842993229932Volume (ft³)Air changes/hour 0.190.37 Equipment Total Load (Sen+Lat)Btuh29826Equiv. AVF (cfm)95185 Req. total capacity at 0.80 SHR ton2.7 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make CarrierTrade15 SEER2 HP Trade 15 SEER2 HPModelGH5SAN44200AA0CondGH5SAN44200AA0AHRI ref 210998696 Coil FJ4DNXC42LAHRI ref 210998696Efficiency7.5 HSPF2 Efficiency 12.0 EER2,14.3 SEER2Heating input Sensible cooling Btuh32000Heating output Btuh @ 47°F42000 Latent cooling Btuh8000Temperature rise °F29 Total cooling Btuh40000Actual air flow cfm1333 Actual air flow cfm1333Air flow factor cfm/Btuh0.050 Air flow factor cfm/Btuh0.050Static pressure in H2O0.50 Static pressure in H2O0.50Space thermostat Load sensible heat ratio 0.88Capacity balance point = 30 °F Backup:Input = 6 kW, Output = 21422 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 1...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name Entire House STOR 2 Exposed wall 346.0 ft 29.0 ft3Room height 9.9 ft 8.0 heat/coolft 4 Room dimensions ft20.5x8.5 5 Room area 3037.5 ft²174.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 216 216 392 324 164 164 298 246.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 432 404 1543 1153 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 12 0 112 127 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 16 0 150 169 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 260 248 450 372 68 68 123 102 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 12 0 112 349 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 519 423 1615 1207 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 72 48 673 1211 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 24 24 250 292 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 216 216 392 324 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 803 692 2642 1974 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 13 13 121 137 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 98 81 916 1065 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 120 106 192 158 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 14 0 135 419 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 260 179 685 512 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 33 0 305 951 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 48 48 500 583 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 572 572 1390 846 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 1283 1283 1096 2243 174 174 149 305CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 473 473 404 826 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 1755 173 5451 0 0 0 0 0 6 c) AED excursion 0 -32 Envelope loss/gain 19524 15241 570 620 12 a)Infiltration 5410 1863 444 153 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 5100 0 Subtotal (lines 6 to 13)24934 23124 1014 773 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal24934231241014773 15 Duct loads 8%15%1935 3579 14%24%144 187 Total room load 26869 26703 1159 960 Air required (cfm)Air required (cfm)1333 1333 57 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 2...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name BED2 STRS2 2 Exposed wall 41.0 ft 4.5 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.0x15.0 ft19.5x4.5 5 Room area 195.0 ft²87.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 36 24 44 36 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 12 0 112 349 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 120 106 192 158 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 14 0 135 419 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 208 208 505 308 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 195 195 167 341 88 88 75 153CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 152 101 Envelope loss/gain 998 1378 231 639 12 a)Infiltration 230 79 69 24 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 400 0 Subtotal (lines 6 to 13)1228 2087 300 663 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution00-300 -66314Subtotal1228208700 15 Duct loads 14%24%175 504 14%24%0 0 Total room load 1403 2591 0 0 Air required (cfm)Air required (cfm)70 129 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 3...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name AHU GRT 2 Exposed wall 15.0 ft 45.0 ft3Room height 8.0 heat/coolft 22.0 heat/coolft 4 Room dimensions ft6.5x8.5 ft402.3x1.0 5 Room area 55.3 ft²402.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 52 52 94 78 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 407 347 1325 990GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 36 24 336 606 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 24 24 250 292WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 583 518 1976 1477GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 65 54 611 710 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 68 68 165 101 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 55 55 47 97 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 0 0 0 0 402 45 1418 0 6 c) AED excursion -12 -225 Envelope loss/gain 307 263 5916 3849 12 a)Infiltration 100 34 1895 652 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13)406 297 7812 5401 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal40629778125401 15 Duct loads 14%24%58 72 -0%0%0 0 Total room load 464 369 7812 5401 Air required (cfm)Air required (cfm)23 18 388 270 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 4...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name MBED DIN 2 Exposed wall 27.5 ft 30.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft226.0x1.0 ft179.0x1.0 5 Room area 226.0 ft²179.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 120 120 458 342 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 80 47 181 135GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 33 27 305 355 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 100 67 257 192 160 112 428 320 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 33 0 305 951 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 48 48 500 583 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 128 128 109 223 90 90 77 157 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 226 28 866 0 179 30 945 0 6 c) AED excursion 401 -28 Envelope loss/gain 1996 2109 2436 1522 12 a)Infiltration 421 145 459 158 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 700 0 Subtotal (lines 6 to 13)2417 3414 2895 1680 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2417341428951680 15 Duct loads 14%24%344 824 14%24%412 406 Total room load 2761 4238 3307 2085 Air required (cfm)Air required (cfm)137 212 164 104 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 5...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name KIT MBTH 2 Exposed wall 17.5 ft 11.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft273.8x1.0 ft140.0x1.0 5 Room area 273.8 ft²140.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 88 72 275 205.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 16 0 150 169 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 140 127 485 362 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 13 13 121 137 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 153 153 131 268 94 94 80 164 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 274 18 551 0 140 11 347 0 6 c) AED excursion -72 -24 Envelope loss/gain 1288 695 851 515 12 a)Infiltration 268 92 168 58 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13)1556 1987 1019 573 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal155619871019573 15 Duct loads 14%24%221 480 14%24%145 138 Total room load 1778 2467 1164 711 Air required (cfm)Air required (cfm)88 123 58 35 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 6...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name BED LAU 2 Exposed wall 29.0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft199.5x1.0 ft7.0x7.5 5 Room area 199.5 ft²52.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 120 120 458 342 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 112 76 290 217 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 36 24 336 606 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 200 29 914 0 53 0 0 0 6 c) AED excursion -78 -20 Envelope loss/gain 1998 1087 0 -20 12 a)Infiltration 444 153 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 400 500 Subtotal (lines 6 to 13)2443 1870 0 480 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal244318700480 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2443 1870 0 480 Air required (cfm)Air required (cfm)121 93 0 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 7...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name WIC BTH2 2 Exposed wall 7.0 ft 6.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x10.5 ft6.0x10.5 5 Room area 73.5 ft²63.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 56 56 214 160 48 36 137 103.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 12 0 112 127 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 9 9 7 15 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 74 7 221 0 63 6 189 0 6 c) AED excursion -8 -10 Envelope loss/gain 442 166 439 219 12 a)Infiltration 107 37 92 32 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)549 203 531 251 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal549203531251 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 549 203 531 251 Air required (cfm)Air required (cfm)27 10 26 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 8...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name MT STRS 2 Exposed wall 0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x4.0 ft13.0x4.0 5 Room area 24.0 ft²52.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 24 0 0 0 52 0 0 0 6 c) AED excursion -2 0 Envelope loss/gain 0 -2 0 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 50 0 Subtotal (lines 6 to 13)0 48 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal04800 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 48 0 0 Air required (cfm)Air required (cfm)0 2 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 9...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name PAN HALL 2 Exposed wall 0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x4.0 ft45.5x1.0 5 Room area 24.0 ft²45.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 24 0 0 0 46 0 0 0 6 c) AED excursion -2 0 Envelope loss/gain 0 -2 0 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 50 0 Subtotal (lines 6 to 13)0 48 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal04800 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 48 0 0 Air required (cfm)Air required (cfm)0 2 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 10...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name BTH HALL2 2 Exposed wall 5.5 ft 27.5 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft5.5x10.5 ft321.0x1.0 5 Room area 57.8 ft²321.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.821.82 1.501.50 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 nn 3.823.82 2.852.85 0 0 0 0 0 0 0 0.GG 1D-c2ov1D-c2ov 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 .GG 1E-c2fv1E-c2fv 0.3500.350 nn 9.359.35 10.5910.59 0 0 0 0 0 0 0 0 11 WW 12E-0sw12E-0sw 0.0680.068 ee 1.821.82 1.501.50 0 0 0 0 40 40 73 60 GG 1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ee 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ee 9.359.35 16.8216.82 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0WW12E-0sw12E-0sw 0.0680.068 ss 1.821.82 1.501.50 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 3.823.82 2.852.85 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.5910.59 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ss 9.359.35 10.8610.86 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.821.82 1.501.50 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 3.823.82 2.852.85 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.3500.350 ww 9.359.35 29.0929.09 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.4110.41 12.1512.15 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.432.43 1.481.48 44 44 107 65 180 180 437 266CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 58 58 49 101 321 321 274 561CC16B-30ad16B-30ad 0.0320.032 --0.850.85 1.751.75 0 0 0 0 0 0 0 0 FF 22A-cpm22A-cpm 1.1801.180 --31.5131.51 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -7 -72 Envelope loss/gain 156 159 784 815 12 a)Infiltration 0 0 77 26 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13)156 159 861 1741 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution0016536614Subtotal15615910262107 15 Duct loads 14%24%22 38 14%24%146 509 Total room load 178 198 1172 2616 Air required (cfm)Air required (cfm)9 10 58 131 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 11:55:25Right-Suite® Universal 2024 24.0.01 RSU62060 Page 11...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Right-J® Worksheet 01/23Date:Entire House JNBy:Strada Services 1 Room name OTB 2 Exposed wall 50.5 ft3Room height 8.0 heat/coolft 4 Room dimensions ft27.0x14.5 5 Room area 391.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-0sw 0.068 n 1.82 1.50 0 0 0 0.W 13A-4ocs 0.143 n 3.82 2.85 0 0 0 0.G 1D-c2ov 0.350 n 9.35 10.59 0 0 0 0 .G 1E-c2fv 0.350 n 9.35 10.59 0 0 0 0 11 W 12E-0sw 0.068 e 1.82 1.50 116 116 211 174 G 1D-c2ov 0.350 e 9.35 29.09 0 0 0 0 W 13A-4ocs 0.143 e 3.82 2.85 0 0 0 0G1D-c2ov 0.350 e 9.35 16.82 0 0 0 0 D 11D0 0.390 e 10.41 12.15 0 0 0 0W12E-0sw 0.068 s 1.82 1.50 216 216 392 324 W 13A-4ocs 0.143 s 3.82 2.85 0 0 0 0G1D-c2ov 0.350 s 9.35 10.59 0 0 0 0G1D-c2ov 0.350 s 9.35 10.86 0 0 0 0 W 12E-0sw 0.068 w 1.82 1.50 0 0 0 0G1D-c2ov 0.350 w 9.35 29.09 0 0 0 0 W 13A-4ocs 0.143 w 3.82 2.85 0 0 0 0 G 1D-c2ov 0.350 w 9.35 29.09 0 0 0 0 D 11D0 0.390 w 10.41 12.15 0 0 0 0 P 12C-0sw 0.091 -2.43 1.48 72 72 175 106C16B-30ad 0.032 -0.85 1.75 392 392 334 685C16B-30ad 0.032 -0.85 1.75 0 0 0 0 F 22A-cpm 1.180 -31.51 0.00 0 0 0 0 6 c) AED excursion -60 Envelope loss/gain 1112 1229 12 a)Infiltration 636 219 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)1748 1447 Less external load 0 0 Less transfer 0 0Redistribution13429714Subtotal18821745 15 Duct loads 14%24%268 421 Total room load 2150 2166 Air required (cfm)107 108 Bold/italic values have been manually overridden 2024-May-20 11:55:27 Right-Suite® Universal 2024 24.0.01 RSU62060 Page 1 ...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N HUBBELL RESIDENCEJob:Duct System Summary 01/23Date:Entire House JNBy: Strada Services Project Information KC CONSTRUCTIONFor: 1101 PALMETTO AVE, SANFORD, FL 32771 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.16in H2O0.16 Available static pressure in H2O0.34in H2O0.34 Supply / return available pressure 0.269 / 0.071 in H2O in H2O0.269 / 0.071 Lowest friction rate in/100ft0.146in/100ft0.146 Actual air flow cfm1333cfm1333 Total effective length (TEL)ft233 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st4100.025.9VlFx0x04.00.2141823464hAHU-A st2110.032.2VlFx0x06.00.189931212443hBED st3100.022.4VlFx0x06.00.220129702591cBED2-A st3100.015.6VlFx0x04.00.233109198cBTH st2150.027.2VlFx0x04.00.1521326531hBTH2 st5135.048.7VlFx0x06.00.1471041643307hDIN st5140.037.8VlFx0x07.00.1511351943906hGRT-A st5135.038.3VlFx0x07.00.1551351943906hGRT-B st4100.024.3VlFx0x05.00.21765291308cHALL2 st3100.018.7VlFx0x05.00.22765291308cHALL2-A st5140.044.7VlFx0x06.00.146123882467cKIT st2115.028.8VlFx0x04.00.187240480cLAU st1120.028.2VlFx0x07.00.1822121374238cMBED-A st1125.026.9VlFx0x04.00.17735581164hMBTH st1125.025.3VlFx0x04.00.1792048cMT st4105.021.4VlFx0x06.00.21354531083cOTB st4100.020.1VlFx0x06.00.22454531083cOTB-A st5140.041.2VlFx0x04.00.1492048cPAN st4100.028.2VlFx0x05.00.2102429579hSTOR-A st4100.021.5VlFx0x05.00.2222429579hSTOR-B st1120.021.7VlFx0x04.00.1901027549hWIC Bold/italic values have been manually overridden 2024-May-20 11:55:27 Right-Suite® Universal 2024 24.0.01 RSU62060 Page 2 ...imating\Hubbell Residence\Hubbell Residence.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 640 499 0.146 815 12.0 0x0 VinlFlx st2 st1 Peak AVF 222 260 0.177 744 8.0 0x0 VinlFlx st2 Peak AVF 787 629 0.146 737 14.0 0x0 VinlFlx st3 Peak AVF 108 205 0.220 766 7.0 0x0 VinlFlx st4 Peak AVF 216 240 0.210 687 8.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 13330 1333 48.5 0.146 611 20.0 x0 0 VlFx Job #: HUBBELL RESIDENCE Performed by JN for: KC CONSTRUCTION 1101 PALMETTO AVE SANFORD, FL 32771 Strada Services Scale: 1 : 104 Page 1 Right-Suite® Universal 2024 24.0.01 RSU62060 2024-May-20 11:55:16 ... Residence\Hubbell Residence.rup N FIRST FLOOR Not Found GRT MBED DIN KIT MBTH BED LAU WIC BTH2 MT STRS PAN HALL 3.5 TON 164 cfm 212 cfm 123 cfm 2 cfm Sup Riser 14 " Sup Riser 8 " 12 x 12 FBB3 7 " FBB1 FBB2 4 "4" Bath Duct to Wall w/Fan KV6" Range Vent to the Wall Cap F F F 4" Dryer Duct to wall Cap w/Dryer Vent Box DV 10 x 10 12 x 12 10 x 10 194 cfm 194 cfm 24 cfm 58 cfm 4 " 2 cfm 4 " 7 "7 " 4 " 26 cfm 4 " 121 cfm 6 "8 " 27 cfm 4 "6 " 6 " 12 " Job #: HUBBELL RESIDENCE Performed by JN for: KC CONSTRUCTION 1101 PALMETTO AVE SANFORD, FL 32771 Strada Services Scale: 1 : 104 Page 2 Right-Suite® Universal 2024 24.0.01 RSU62060 2024-May-20 11:55:16 ... Residence\Hubbell Residence.rup N SECOND FLOOR Not Found STRS2 BED2 STOR AHU BTH HALL2 OTB ATTIC2 ATTIC LRB 1 F SRB 1 10 cfm 1333 cfm 10 x 10 10 x 10 10 x 10 4 " 6 " 5 "29 cfm 29 cfm 5 " Sup Riser 14 " 8 " 7 " Sup Riser 8 " 14 " 8 " 8 " 4" Bath Duct to Roof w/Fan 129 cfm 6 " 5 "65 cfm 10 x 10 8 " 20 " 54 cfm 6 " 54 cfm 65 cfm 5 " 23 cfm4 "