Loading...
HomeMy WebLinkAboutREVIEW COMPLETE - REVISED ELEC LOAD CALC 101 Palmetto AveMODEL: BUILDER: SUBDIVISON: ADDRESS: VOLT/AMPS TON QTY KW LARGEST LOAD:17608 2 4032 10000 6500 0 *Includes Heat Pump and Heat Strips on together @ 100% 2.5 5040 10000 6500 0 3 5280 10000 6500 0 Square Feet Living Area 2988 3 Volt/Amps 8964 3.5 1 6168 8000 5200 11368 Small Appliance Circuits 3 4500 4 6888 8000 5200 0 Laundry Circuit 1 1500 5 8160 10000 6500 0 Dishwasher 2 3000 Water Heater 2 9000 11368 Range 1 8000 AC EP1 35.5 12 2.958333 Oven 0 4.98 Cooktop 0 Microwave 1 1100 TON QTY KW Dryer 1 5000 1.5 1 2990 5000 3250 6240 Disposal 2 1000 2 4032 5000 3250 0 60A Pool Pump 1 12000 2.5 5040 5000 3250 0 3 5280 5000 3250 0 Misc:________________3.5 6168 5000 3250 0 Misc:________________4 6888 5000 3250 0 TOTAL OTHER LOAD:__________________________________________54064 5 8160 5000 3250 0 FIRST 10KVA @ 100%:10000 6240 REMAINDER @ 40%:17626 LARGEST LOAD:17608 TOTAL LOAD:45234 188 AMPS 30 240 0 1 50 240 12000 100 240 0 12000 Note: This Load Calc is based on the information provided by the builder. The recommended service size will be installed leaving sufficient usage for future homeowner. 5 KW SETUP 10 KW SETUP HEAT PUMPS W/SUPPLEMENTAL HEAT* POOL PRE-WIRES RECOMMENDED SERVICE SIZE:300 MINIMUM PER NEC:200 KC Const 1101 S Palmetto VA ÷ 240 VOLTS = ELECTRICAL SERVICES, INC.STATE CERT. LIC EC13003715 Sanford, FL HOLDER: JOSEPH STRADA NEC 2017/FBC 107 3400 St Johns Pkwy 877-906-1113 ELECTRICAL LOAD CALCULATIONS UPDATED 1-15-2021