HomeMy WebLinkAbout1807 Peach Ave - BR24-001117 (new sfh) aCOVER SHEET C S N.T.S.LP HANDYMAN LLCLOT 3 PEACH AVENUESanford, Fl. 32771REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES LOT #3 PEACH AVENUE E1 FLOOR PLAN ELECTRICAL & LINTEL PLAN CS COVER SHEET A1 INDEX OF DRAWINGS: A2 ELEVATIONS FOUNDATION PLANA0 D1 DETAILS D2 DETAILS Phone: 407-947-7549 KLP SDS DESIGN SERVICES Tim Perry 235 S. Maitland Avenue, Suite 216 Maitland, Florida 32751 2023 FLORIDA BUILDING CODE 8th EDITION, BUILDING NATIONAL ELECTRICAL CODE 2017 2023 FLORIDA BUILDING CODE 8th EDITION, PLUMBING 2023 FLORIDA BUILDING CODE 8th EDITION, MECHANICAL 2023 FLORIDA BUILDING CODE 8th EDITION, ENERGY CONSERVATION 2023 FLORIDA BUILDING CODE 8th EDITION, RESIDENTIAL REFERENCED BUILDING CODES: DESIGN LOAD REQUIREMENTS: CONSTRUCTION TYPE V-B NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS OF THE 2023 FLORIDA BUILDING CODE RESIDENTIAL 8TH EDITION ASCE 7-16 1. DESIGN WIND SPEED - V asd108MPH/ V ult - 140MPH 2. RISK FACTOR II 3. WIND EXPOSURE - CATEGORY (C) 4. INTERNAL PRESSURE COEFFICIENT- (ASCE 7-16) ENCLOSED BUILDINGS= 0.18 HEIGHT AND EXPOSURE ADJUSTMENT COEF.- (+1.26) 5. COMPONENTS AND CLADDING : PER FBCR 2023 8TH EDITION R301.2(2) SEE WINDOW AND DOOR REQUIREMENTS Pedro L. Medina, P.E. Professional Engineer Fl. P.E. # 73579 pedro@prodcfl.com Phone: 407-947-7549 a) Uninhabitable attic without storage: 10psf, b) Uninhabitable attic with limited storage: 20psf, c) Habitable attics and attics served with fixed stairs: 30psf, d) Balconies (exterior) and decks: 60psf, e) Guards and handrails: 200psf, f) Guard in-fill components: 50psf, g) Guards and handrails: 200psf, g) Passenger vehicle garages: 50psf, h) Rooms other than sleeping room: 40psf, i) Sleeping rooms: 30psf, j) Stairs: 60psf. M1 MECHANICAL PLAN P1 PLUMBING PLAN S1 TRUSS LAYOUT AND FRAMING PLAN SP SITE PLAN Sanford, Fl. 32771 NORTH6" THICK CONCRETE APRON4" THICK CONCRETE DRIVE(2,500 PSI MIN.)(3,500 PSI MIN.) WATER METER1" SCHED 40 WATER LINE-3" TO -6" R1 3' wide 1.5'1.5' CL GRADE SITE PLAN SP 1" =10'LP HANDYMAN LLCLOT #3 PEACH AVENUESanford, Fl. 32771REVISIONSJOB NO. P9858 DRAWN BY: TKP DATE: 02/18/2024 SCALE: KLP DESIGN SERVICES WASHDRYERAHU12x12 R/ACLCLR1CLR1CLR115 SEER MIN. ACU R1LEGAL DESCRIPTION: (AS FURNISHED) LOT 3. BLOCK 8, PINE LEVEL. ACCORDING TO THE PLAT THERE OF AS RECORDED IN PLAT BOOK 6. PAGE(S) 36 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY. FLORIDA. BASIS OF BEARINGS: BEARINGS SHOWN HEREON ARE BASED ON THE SOUTHERLY LINE OF LOT 3, BLOCK 8, BEING WEST, ASSUMED SUBJECT PROPERTY SHOWN HEREON APPEARS TO BE LOCATED IN FLOOD ZONE X. AREA OUTSIDE OF THE 100 YEAR FLOODPLAIN. PER F.I.R.M. PANEL NUMBER 12117C 0070F LAST REVISION DATE 09/28/07 THIS SITE PLAN IS NOT A SURVEY THIS SHEET IS FOR HOUSE PLACEMENT ONLY KLPSDS IS NOT RESPONSIBLE FOR ANY CIVIL INFORMATION OR SETBACK REQUIREMENTS CONTRACTOR TO VERIFY ALL SITE INFORMATION WITH OTHERS PRIOR TO CONSTRUCTION 101.8' F.F.E. 100. 0' E L. X 100. 0' E L. X FOUNDATION PLAN STEP DOWN THICKENED EDGE REBAR EACH WAY 24X24X12 W/ 3#5 S' 11A 14 1 #5 CONT 8" 6" X6" P.T. POST TYPICAL COLUMN PAD 16" 24" ABE66 MONOLITHIC THICKENED EDGE 10 8" X 8" 12" MIN. GRADE 8" 1 #5 CONT 8" 8"x16" CONC. BLOCK #5 DOWEL W/ LAP 25" MIN.LAP ASSUMED GRADE 2 #5 BARS MIN 25" LAP CLEAN, COMPACTED TERMITE TREATED 1 FILL BARRIER 6 MIL VAPOR 16" X 20" FOOTING DETAIL SINGLE STORY BLOCK 16" 12" MIN OR FIBERMESH TYP. CONC.SLAB W/ 6x6, 10/10 W.W.M. 8" MIN 4" 3" MIN LAP 2'-1"MIN. DOWEL (1)#5 REBAR CONT. 8" CMU TYP. 8" VARIES BARRIER 16" SINGLE STORY TYP. WALL SECTION (2) #5 RE-BAR W/ 25" MIN. LAPTERMITE TREATED CLEAN, COMPACTED FILL 6A INTERNAL BEARING STEP DOWN 6 MIL VAPOR 4" MIN. 3#5 S' EACH 15. NO WOOD GRADE STAKES ALLOWED BOND BEAM MAX 10" FROM FINISHED FLOOR 14. ANY CMU WALL ABOVE 12'-0" MUST HAVE ADDITIONAL CONT. 3. CONCRETE 28 DAY STRENGTH SHALL BE MINIMUM 2500 PSI W/ 3/4" MAXIMUM AGGREGATE 1. FOUNDATION DESIGN BASED ON ASSUMED 2000 P.S.F. MIN. ALLOWABLE BEARING PRESSURE 12" BELOW FINISH GRADE FOOTING ON PLANS. LAP VERTICAL BARS TO DOWELS(SEE MASONRY NOTES) SHALL BE #5 DOWEL BARS W/ A MIN STD HOOK LOCATED AS SHOWN 6. REINFORCED STEEL: ASTM A615, GRADE 40. VERTICAL REINFORCEMENT OR 6X6 10/10 WWM OVER 6MIL VAPOR BARRIER OVER 2. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318. 5. ALL EXTERIOR BEARING FOOTINGS TO BE MINIMUM CLEAN COMPACTED TERMITE TREATED SOIL. 4. 4" THICK CONCRETE SLAB (2500#PSI) W/ FIBER MESH IF STEMWALL EXCEEDS 72" CONSULT WITH ENGINEER OF RECORD AND 1 #5 HORIZONTAL @ 24" O.C. IN U-BLOCK GROUT AND APPLY 1 #5 VERTICAL @ 4' O.C. MAX 2. IF STEM WALL EXCEEDS 48", FILL ALL CELLS WITH GROUT AND APPLY 1 #5 VERTICAL @ 4' O.C. MAX. 7. 1. IF STEMWALL EXCEEDS 32", FILL ALL CELLS WITH CORNER BARS SHALL BE LAPPED 25" TO FORM CONTINUITY IN THE FOUNDATION/MASONRY NOTES AN OPENING ADD CORRUGATED (GALV.) WALLTIES. 32" O.C. HORIZONTAL SPACING 18" O.C. VERTICAL SPACING 6' O.C. MAX. AND AT EACH SIDE OF 8. TYPICAL- FILLED CELL WITH 1#5 10. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY SLAB/FOOTING WITH 6" EPOXY EMBEDMENT MIN 25" LAP 12. IF J-BOLT IS MISSED USE (1) 5/8" X 8" WEDGE ANCHOR 13. ALL CONTINUOUS STEEL TO HAVE MIN 25" LAP 11. IF FILLED CELL WITH 1#5 IS MISSED RETRO 1#5 IN 9. EXTENDED FOOTING 4" FOR 4" BRICK/STONE VENEER CONTRACTOR TO VERIFY THAT ALL FOOTINGS REQUIRED BY TRUSS MANUFACTURER OR STRUCTURAL FRAMING ARE REFLECTED ON FOUNDATION PLAN PRIOR TO CONSTRUCTION. PLUMBING NOTES 1. COMPLY WITH 2023 FLORIDA PLUMBING CODE AND ALL OTHER LOCAL CODES 2. COORDINATE WORK OF THIS TRADE WITH ALL OTHER TRADES. 3. PROVIDE A MINIMUM PITCH OF 1/8" AT ALL HORIZONTAL BRANCHES AND SEWER LINES. LINES LESS THAN 2 1/2" TO BE 1/4" FALL. 4. PROVIDE A CLEANOUTS AT THE BASE OF EACH SOIL AND WASTE STACK. 5. PROVIDE MEANS OF RESEALING ALL FLOOR DRAINS. 6. PROVIDE SAFE WASTE FOR AIR CONDITIONING UNIT CONDENSATE W/ TRAP. 7. PROVIDE AIR CHAMBERS FOR ALL WATER SUPPLIES FEEDING FIXTURES. 8. PROVIDE VACUUM BREAKER AND SHUT-OFF VALVE ON ALL HOSE BIBS. 9. A VENT TERMINAL FROM A DRAINAGE SYSTEM SHALL NOT BE LOCATED DIRECTLY BENEATH ANY DOOR, WINDOW, OR OTHER VENTILATING OPENING OF THE BUILDING OR OF AN ADJACENT BUILDING, NOR SHALL ANY SUCH VENT TERMINAL BE WITHIN TEN (10) FEET HORIZONTALLY OF ANY SUCH OPENING UNLESS IT IS AT LEAST TWO (2) FEET ABOVE THE TOP OF SUCH. 10.WATER HAMMER ARRESTORS REQUIRED WHERE QUICK CLOSING VALVES ARE UTILIZED. (WASHING MACHINES, DISHWASHER, ICE MAKER) FOUNDATION PLAN DESIGN REQUIREMENTS: A. FLOORS LIVE LOAD IS 40 PSF,BALCONIES, DECKS, STAIRS, LIVE LOAD IS 60 PSF. B. ROOF LIVE LOAD IS 30 PSF CONSTRUCTION TYPE V-B NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS OF THE 2023 FLORIDA BUILDING CODE RESIDENTIAL 8TH EDITION ASCE 7-16 1. DESIGN WIND SPEED - V asd 108MPH/ V ult - 140MPH 2. RISK FACTOR II 3. WIND EXPOSURE - CATEGORY (C) 4. INTERNAL PRESSURE COEFFICIENT- (ASCE 7-16) ENCLOSED BUILDINGS= 0.18 HEIGHT AND EXPOSURE ADJUSTMENT COEF.- (+1.26) PER FBCR 2020 7TH EDITION R301.2(3) 5. COMPONENTS AND CLADDING : PER FBCR 2023 8TH EDITION R301.2(2) SEE WINDOW AND DOOR REQUIREMENTS A - 0 1/4" = 1'-0" REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES MONO FOOTING DETAIL @ GARAGE TERMITE TREATED 3 FILL 16" X 20" 16" SINGLE STORY BLOCK 2 #5 BARS MIN 25" LAP CLEAN, COMPACTED TYP. CONC.SLAB W/ 6x6, 10/10 W.W.M.OR FIBERMESH BARRIER6 MIL VAPOR 12" MIN 8" MIN VARIES 5/8" x 6" WEDGE VARIES INTERNAL BEARING STEP DOWN 6 TERMITE TREATED CLEAN, COMPACTED 8" SINGLE STORY 16" X 8" 6 MIL VAPOR BARRIER 25" MIN. LAP (2) #5 RE-BAR W/ ANCHOR BOLTS 32" O.C. TYP. WALL SECTION 16" ASSUMED GRADE 2x4 STUDS 16" O.C. CONTINIOUS2x4 P.T. BOTTOM PLATE 1/2" DRYWALL TYP. CONC.SLAB W/ 6x6, 10/10 W.W.M.OR FIBERMESH LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771 15 seer ACUWASH AHU 3 TON DRYER A0 14 RECESS 3/4" A0 3 A0 3 A0 3 A0 6 A0 1 3" PVC CHASE A0 6 A0 1 A0 11A A0 10 A0 10 A0 11A A0 6A 4" THICK CONCRETE SLAB (2500#PSI) W/ FIBER MESH OR 6x6 10/10 WWM OVER 6MIL VAPOR BARRIER OVER CLEAN COMPACTED TERMITE TREATED SOIL A0 1 A0 1 A0 1 A0 14 25SHEGRESS25 SHEGRESSHALL BATH W.I.C. BEDROOM MASTER ABEDROOM #2 9'-4" CLG.BATH &SHOWERH.C.BATH 15 seer ACU24SHLIVING ROOM 25SHEGRESSC 10'-0" X 8'-0" O.H.D. ATTIC ACCESS GARAGE WASHAHU3 TONDRYER 1 3/8"SOLIDCOREREF.RANGE/OVEN DWSINKDINING AREA 9'-4" CLG. 6068 B.P.LINENBEDROOM #3 AAAPANTRYAPR 25 SH FRONT PORCH 9'-4" CLG. 9'-4" CLG.W/ AUTO CLOSER1/2" DRYWALL6068 B.P. 9'-4" CLG. 9'-4" CLG. 2868 BARN DR. 9'-4" CLG. 9'-4" CLG. 9'-4" CLG. 9'-4" CLG.1/2" DRYWALLB6068 SGDKITCHEN 9'-4" CLG.BEARING WALL22 X 36BATH &SHOWER2068 B.F. FLOOR PLAN A - 1 1/4" = 1'-0" LIVING FLOOR AREA 1,420 S.F. FRONT PORCH 87 S.F. TOTAL SQ FT 1,844 S.F. GARAGE 337 S.F. JOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES AREA TABULATIONS FLOOR PLAN GARAGE DOOR SHALL BE TESTED IN ACCORDANCE WITH ANSI/DASMA 108 OR TAS202. FBCR 2023 8TH EDITION 1609.7 (1) OVERHEAD DOORS MUST MEET OREXCEED MIN REQ. OF +31.0 PSF/ -35.1 PSFC A 2020/140 MPH EXTERIOR WINDOW REQUIREMENTS EXTERIOR WINDOWS AND GLASS DOORS MUST MEET THE REQUIREMENTS OF R301.2(2) OF THE FLORIDA BUILDING CODE 2023 RESIDENTIAL 8TH EDITION EXTERIOR WINDOWS AND GLASS DOORS TESTING AND LABELING EXTERIOR WNDOWS AND GLASS DOOR SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING LABORATORY, AND BEAR AN AAMA OR WDMA OR OTHER APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF THE FOLLOWING SPECIFICATION: WINDOWS-ANS/AAMA/NWWDA 101/IS2 2/97 COMPONENTS AND CLADDING MUST MEET REQ. OF +35.3 PSF/ -47.2 PSF 2020/140 MPH EXTERIOR DOOR REQUIREMENTS EXTERIOR DOORS SHALL BE CAPABLE OF WITHSTANDING POSITIVE AND NEGATIVE WIND PRESSURES AS DETERMINED BY FBCR301.2(2) EXTERIOR DOORS MUST BE MEET OR EXCEED MIN REQ. OF +33.7 PSF/ -36.7 PSF B DESIGN REQUIREMENTS: A. FLOORS LIVE LOAD IS 40 PSF,BALCONIES, DECKS, STAIRS, LIVE LOAD IS 60 PSF. B. ROOF LIVE LOAD IS 30 PSF CONSTRUCTION TYPE V-B NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS OF THE 2023 FLORIDA BUILDING CODE RESIDENTIAL 8TH EDITION ASCE 7-16 1. DESIGN WIND SPEED - V asd 108MPH/ V ult - 140MPH 2. RISK FACTOR II 3. WIND EXPOSURE - CATEGORY (C) 4. INTERNAL PRESSURE COEFFICIENT- (ASCE 7-16) ENCLOSED BUILDINGS= 0.18 HEIGHT AND EXPOSURE ADJUSTMENT COEF.- (+1.26) PER FBCR 2023 8TH EDITION R301.2(3) 5. COMPONENTS AND CLADDING : PER FBCR 2023 8TH EDITION R301.2(2) SEE WINDOW AND DOOR REQUIREMENTS LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771 ELEVATIONS A - 2 R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. TOTAL AREA OF ROOF TO BE VENTED - 1,844 SQ. FT./ 150= 12.29 SQ. FT. REQUIRED TOTAL VENTILATION PROVIDED- 43.00 SQ.FT. OF CLEAR VENTILATION (4)-1 X 4 OFF RIDGE VENTS - 4 X 1.75 SQ. FT. = 7.0 SQ. FT. OF CLEAR VENTILATION VENTED SOFFIT- 120 LN. FT. X 12"= 120 SQ. FT. @ 30% OF CLEAR VENTILATION= 36 SQ.FT. 1/4" = 1'-0"LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES RIGHT ELEVATION SHINGLE ROOF 0'-0" A.F.F. 9'-4" BEARING O.H. FIBERGLASS ASPHALT 8'-0" LINTEL O.H. 5 12 5/8" STUCCO 5 12 SHINGLE ROOF 0'-0" A.F.F. 9'-4" BEARING O.H. FIBERGLASS ASPHALT 8'-0" LINTEL FRONT ELEVATION 5 12 SHINGLE ROOF 0'-0" A.F.F. 9'-4" BEARING O.H. FIBERGLASS ASPHALT 8'-0" LINTEL REAR ELEVATION O.H. 5/8" STUCCO 5 12 SHINGLE ROOF 0'-0" A.F.F. 9'-4" BEARING O.H. FIBERGLASS ASPHALT 8'-0" LINTEL LEFT ELEVATION O.H.O.H. 5 12 5/8" STUCCO5/8" STUCCO 5/8" STUCCO 5/8" STUCCO O.H.O.H. ELECTRICAL & LINTEL PLAN Rebar provided in precast lintel per ASTM A615 GR60. minimum net area compressive strength = 1900 psi. Concrete masonry units (CMU) per ASTM C90 w/ f'c grout = 3000 psi w/ maximum 3/8" aggregate. f'c precast lintels = 3500 psi. f'c prestressed lintels = 6000 psi. longer with a nominal height of 8" meet or exceed L/180. Bottom field added rebar to be located at the bottom of the lintel cavity. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and Lintels are manufactured with 5-1/2" long notches at the ends to accommodate Installation of lintel must comply with the architectural and/or structural drawings. vertical cell reinforcing and grouting. 7/32 wire per ASTM A510. Shore filled lintels as required. Prestressing strand per ASTM A416 grade Mortar per ASTM C270 type M or S. Provide full mortar head and bed joints. Cast-in-place concrete may be provided in composite lintel in lieu of concrete masonry units. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. For composite lintel heights not shown, use safe load from next lower height. The designer may evaluate concentrated loads from the safe load tables by One #7 rebar may be substituted for two #5 rebars in 8" lintels only. Safe loads are total superimposed allowable load on the section specified. Additional lateral load capacity can be obtained by the designer by providing All safe loads in units of pounds per linear foot. addional reinforced masonry above the precast lintel. Safe loads based on grade 40 or grade 60 field rebar. lintels must be reduced by 20% if bearing length is less than 6-1/2". All values based on minimum 4" bearing. Exception: Safe loads for unfilled Safe loads for all recessed lintels based on 8" nominal bearing. USAFE LOAD TABLE NOTES Field rebar per ASTM A615 GR40 or GR60. 9. 8. 7. 6. 5. 4. 3. N.R. = Not Rated.2. 1. 7. 5. 9. 8. 6. 7. 4. 3. 2. UGENERAL NOTES 1. 8. 2. 5. 270 low relaxation. 6. 4. 3. UMATERIALS 1. A DIVISION OF FLORIDA ENGINEERED CONSTRUCTION PRODUCTS CORPORATIONP.O. Box 24567 Tampa, Florida 33623 HIGH STRENGTH PRECAST AND PRESTRESSED CONCRETE LINTELS AND SILLS Phone: 813-621-4641 (2) 7/16" Diameter Prestressing Strands. U-Precast Lintel (8"X16" composite) Total Allowable Superimposed Load - Pounds Per Linear Foot (P.S.) represent precast lintels prestressed using 5'4"4'0"L-5 14'0"12'8"L-15 L-17 (P.S.) L-18 (P.S.) L-19 (P.S.) L-22 (P.S.) L-20 (P.S.) L-21 (P.S.) L-16 (P.S.) Note: 20'0"18'8" 22'8" 20'8"21'4" 24'0" 16'0" 14'0" 18'0" 13'4" 17'4" 19'4" 14'8" 15'4" 9'4"8'0"L-10 10'0" 9'2" 12'0" 11'2"L-13 L-14 L-11 L-12 12'6" 13'4" 10'6" 11'4" 6'2" 5'2" 4'6" 7'0" L-8 L-9 L-7 L-6 7'6" 8'4" 6'6" 5'10" Mark No. SpanSpan 1'6" 3'2" 2'8" 2'2" L-3 L-4 L-2 L-1 4'0" 4'6" 3'6" 2'10" Nominal Clear Total Lintel 46494546 4753 6790 70152'-4"D-2 2'-8" D-4 D-3 D-7 D-6 D-9 D-8 D-5 13891356 1421 801 1250 1063 954 1104 1512 1437 980 1017 740 880 913 775 1153 1019 1395 1326 1197 1057 1448 1376 3042 1832 1507 1628 2319 2009 2666 4212 3538 22672215 1554 1438 1749 1918 1591 1473 1936 1790 2908 2548 4028 3382 2975 2607 3460 4120 4'-0"4'-4" 6'-4" 8'-4" 5'-4" 6'-0" 8'-0" 5'-0" 3'-0" 3'-4" 2'-10" 2'-8" 3'-0" 2'-6" 4956 4049 2650 2026 3138 2755 2078 3267 6018 5391 6320 6124 5432 6539 D-1 No. Mark (2)#5 T & B 12867 6033 8871 7178 Filled C D 6868 5772 12374 8488 7023 5902 8680 12591 (1)#5T(2)#5B Filled (1)#5 T&B E 2" Recessed Door Headers (8"x14", Composite) Total Allowable Superimposed Load - Pounds Per Linear Foot DoorNominal Span 2'-4" Clear Width 2'-0" Size Filled Filled B 7980 (0)#5B,(1)#5T C 8199 (1)#5T(1)#5B 7168 4198 2855 2130 3340 6288 5631 6642 Filled D 8426 (1)#5B,(2)#5T ELECTRICAL PLAN SECURITY SYSTEM PUSH BUTTON-CHIME PUSH BUTTON-GARAGE DR OPENER SWITCH ACTIVATED RECEPTACLE DUPLEX RECEPTACLE 110/120 DEDICATED RECEPTACLE WEATHER PROOF SWITCHSDDIMMER SWITCH 4 WAY SWITCH TSS4SWPTIME SWITCH CH T THERMOSTAT CHIMES T TIMER RELAY PADDLE FAN GARAGE DOOR OPENER SMOKE DETECTORS/D TV HEAT LAMP/ EXHAUST FAN COMBO RECESSED FLUORESCENT FIXTURE SURFACE MOUNT FLUORESCENT FIXTURE TRACK LIGHTING FIXTURE J MOTION FLOOD LIGHT JUNCTION BOX S3SSWITCH EXHAUST FAN 3 WAY SWITCH SURFACE MOUNTED LIGHT RECESSED VAPOR PROOF LIGHT RECESSED HIGH HAT WALL MOUNTED LIGHT VP DEDICATED DISCONNECT PANEL MAIN DISCONNECT PANEL M INTINTERCOM ELECTRIC METER BREAKER PANEL TELEVISION JACK TELEPHONE JACK ROUTED WIRE GROUND FAULT RECEPTACLE WEATHER PROOF RECEPTACLE QUADRUPLEX RECEPTACLEGFIWP 220-VOLT RECEPTACLE FLOOR RECEPTACLE CARBON MONOXIDE DETECTORCO2 CAT 5 CAT 5PUSH BUTTON-G. DISPOSAL CHANDELIER JB J-BOX GENERAL ELECTRICAL NOTES THIS DIAGRAMMATIC ELECTRICAL PLAN IS INTENDED TO SHOW LIGHTING AND CONVENIENCE OUTLETS ONLY. THE ENGINEER OF RECORD BEARS NO RESPONSIBILITY FOR ITS ACCURACY. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE REQUIREMENTS AND LOCATIONS OF ELECTRICAL EQUIPMENT AND PROVIDING AND INSTALLING COMPLETE ELECTRIC SERVICE AS MAY BE REQUIRED BY THE NEC/17. THE ELECTRICAL CONTRACTOR IS TO SUBMIT PLANS AND PULL PERMITS AS REQUIRED. DWELLING ROOMS TO BE "AFCI" PROTECTED PER ARTICLE 210.12 NEC2017, GROUND-FAULT CIRCUIT INTERRUPTER FOR PERSONAL 210.8 BONDING OF OTHER SYSTEMS 250.96, AND TO HAVE TAMPER-RESISTANT RECEPTACLES. ALL SMOKE DETECTORS & CARBON-MONOXIDE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. SWITCHED LIGHT FIXTURE TO BE IN EACH ATTIC ACCESS. ALL WIRING TO MEET OR EXCEED THE 2017 NATIONAL ELECTRICAL CODE METER AND PANEL BASE G 20' OF #4 BARE COPPER TO FOOTING STEEL 6' MIN. 15 GFI30 ACU 1 3 5 7 GFI #4 COPPER GRND #4 COPPER GRND TO TRANSFORMER DISC 3-2/O COPPER W/ 1 #4 COPPER GRND & 2 1/2" PVC INTERIOR PANEL 22,000 AIC AMP 120/240 V NEMA 3R 42 CRKT. 2- 3/4" X 10' COPPER CLAD DRIVEN GROUND RODS A150 150 300 E1 1/4" = 1'-0" REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771 15 seer ACUWASH DRYERS M150A & METER BASE MAIN DISC. @42"SS@42"S@42" TV @60"SSSL - 8 C GFI/WP D - 5 C TV @60" L - 12 CSL - 8 C GFI/WP SPENDANT GFI GFI GFISSSS GFI/WP L - 4 C GFI GFIGFIGFIGFI GFIGFISSSVP S3STV S/D SSTV @60" L - 4 CSSGFIS S/D TV L - 4 C L - 4 C AHU 3 TON L - 7 C L - 10 C L - 4 C VP S/D S/D CO2 MECHANICAL M1 1/4" = 1'-0" REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES AHU REFRIGERANT LINES PRIMARY CONDENSATE SUPPLY AIR DUCT DRAIN LINE. SEE PLANS FOR TERMINATION ROOF RETURNAIR DUCT AHU SUPPORT BASE SIZE TO FITRETURNAIR DUCTAHU DETAIL SCALE = N.T.S. PROVIDE AS CPVC OR COPPER PREMANUFACTURED VENT CLEANOUT WITH 12" EXTENSION FLOAT SWITCH IN AIR HANDLING UNIT CONDENSATE DRAIN PAN SECONDARY DRAIN LINE TO DISABLE AHU SHOULD SECONDARY DRAIN LINE ACCUMULATE WATER. NOT REQUIRED IF A SECONDARY DRAIN PAN IS USED. PIPE WITH THREADED CAP AT END. SLIP-FT (NOT SCREW) CAP WITH DRILLED HOLE TERMINATE VENT CLEANOUT AT LEAST 1" ABOVE FLOAT SWITCH TRIPPING HEIGHT, IN SECONDARY DRAIN. 2" TRAP AT LEAST 3" DEEP. WITH CLEANOUT IS ACCEPTABLE. WITHIN PLENUM RETURN MECHANICAL CLOSET. 4" CONDENSATE TRAP DETAIL SCALE = N.T.S. HVAC GENERAL NOTES 1.ALL SIZES ARE IN INCHES UNLESS OTHERWISE NOTED. 2.ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. 3.ALL EQUIPMENT AND DUCTWORK SHALL BE SUPPORTED ACCORDING TO SMACNA STANDARDS. SUPPLY AND RETURN DUCTWORK SHALL BE FIBERGLASS4. MIN. R-6.5 TO COMPLY WITH 2023 FLORIDA ENERGY CODE. ALL FIBERGLASS DUCT TO BE SEALED WITH GLASS FAB AND MASTIC. OUTSIDE AIR AND EXHAUST DUCTS TO BE METAL.5. (GALVANIZED OR ALUMINUM - WALL CAPS MAY CONTAIN PLASTIC HOUSING AND/OR BACKDRAFT DAMPER) INSULATE DIFFUSER BACK AND NECK WITH R-6.0 BATT6. INSULATION, SEAL FLEXIBLE DUCT CONNECTION WITH GLASS FAB AND MASTIC. CONDENSATE PIPING TO BE 3/4" SCHEDULE 160 PVC 7. UNLESS OTHERWISE NOTED. MOUNT THERMOSTATS AT 4'-4" A.F.F.8. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE9. FLORIDA MECHANICAL CODE 2023 AND 2023 FLORIDA ENERGY CODE. SUCTION REFRIGERANT PIPING TO BE INSTALLED WITH10. MIN. 3/8" THICK CELLULAR RUBBER ARMAFLEX. ALL EQUIPMENT TO BE INSTALLED WITHIN MANUFACTURER'S 11. SPECIFICATIONS AND SERVICE CLEARANCE REQUIREMENTS. GALV. RIGID DUCT TO EXTERIOR W SPEC.DUCT SIZE NOTES: 1. 2. 3. BACKDRAFT DAMPER FOR BATH EXHAUST USE. PRIME COAT AND PAINT TO MATCH ROOF COLOR. PROVIDE FLASHING AND COUNTER FLASHING. PROVIDE BIRD SCREEN AND OMIT EXHAUST ROOF CAP DETAIL SCALE = N.T.S. AT THE JOINING OF THE PIPE AND THE COLLARED ROOFCAP CONNECT DUCT INSIDE COLLAR AND SEAL WITH FOIL BACKED TAPE SLOPED ROOF CAULK WEATHER TIGHT GALV. STEEL OR ALUMINUM DUCT MADE WATERTIGHT. STIFFENERS MAY BE DUCT S I Z E +25% DUCT S I Z E SCALE = N.T.S. MECHANICAL DETAILS N.T.S. MECHANICAL PLAN LP HANDYMAN LLCPEACH AVENUESanford, Fl. 327711 1/30/23 15 seer ACUWASH DRYER 5 X 8 SA 75 CFM'S 4" DIA. R-6 50 CFM E.F. 5 X 8 SA 75 CFM'S 4" DIA. R-68x10 150 CFM 6" DIA. R-6 12x12 R/A 10" DIA. R-6.5 AHU 3 TON 20x20 R/A 12x12 R/A 10" DIA. R-6.5 8x10 SA 200 CFM 7" DIA. R-6 6 X 10 SA 100 CFM'S 4" DIA. R-6 50 CFM E.F. 10x10 4-way 180CFM 7" DIA. R-6 8x16 SA 250 CFM 8" DIA. R-6 12x12 R/A 12" DIA. R-6.5 1 1/30/23 12" DIA. R-6.5 RANGE HOOD VTR 8x10 SA 200 CFM 7" DIA. R-6 8x10 150 CFM 6" DIA. R-6 DVTW SECTION 905 VENT CONNECTIONS AND GRADES 905.1 Connection. All individual, branch and circuit vents shall connect to a vent stack, stack vent, air admittance valve or extend to the open air. 905.2 Grade. All vent and branch vent pipes shall be so graded and connected as to drain back to the drainage pipe by gravity. 905.3 Vent connection to drainage system. Every dry vent connecting to a horizontal drain shall connect above the centerline of the horizontal drain pipe. 905.4 Vertical rise of vent. Every dry vent shall rise vertically to a point not less than 6 inches (152 mm) above the flood level rim of the highest trap or trapped fixture being vented. Exception: Vents for interceptors located outdoors. 905.5 Height above fixtures. A connection between a vent pipe and a vent stack or stack vent shall be made at not less than 6 inches (152 mm) above the flood level rim of the highest fixture served by the vent. Horizontal vent pipes forming branch vents, relief vents or loop vents shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture served. 905.6 Vent for future fixtures. Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent shall be installed. The vent size shall be not less than one-half the diameter of the rough-in drain to be served. The vent rough-in shall connect to the vent system, or shall be vented by other means as provided for in this chapter. The connection shall be identified to indicate that it is a vent. MECHANICAL P1 1/4" = 1'-0" REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771WC TUB TO SEWER LATERAL 4" LAV 2" VTR2" WCO 3"WC TUB LAV 2"VTR 2" SINK 2" 2" 2" WCO 4" 4 TWO-WAY SANITARY CLEAN OUT @ GRADE 4" PVC ( MEETING ASTM D3034 MIN. STANDARDS ) 2"3" 2" 2" 2"2" 3" LAV 3"VTR 2" 3" 3" 3"3" 3" 2" 2" 2" LAV 4 TWO-WAY SANITARY CLEAN OUT @ GRADE 4" 2" 2"VTR WASHING MACHINE 2" 2" 4" 4" WC TUB 3" LAV TO SEWER LATERAL 2" 2"VTR 2" 3" WCSHOWER2" 2" 3" 3"VTR 2"VTR SINK 2" 2" 2" 2"WCO 4" 3"3" 3" 3" LAVLAV 3" 2"WCO 3" 3" 2" 2"2"2" 2" 2" TRUSS LAYOUTTRUSS LAYOUT & FRAMING PLAN STUDS AND 1- HTT5ATO SLAB/ BOND BEAM 2- HTS20 STRAPS- GIRDER/BEAM TO POST/ MULTIPLE 24-16d 4 3 2 22-10d/ 5/8" ANCH. 32-16d/ 5/8"ANCH. 48-10dx1 1/2 18-16d/ 5/8"ANCH. 12-16d/ 5/8"ANCH. 28-16d- - - - - FRAME C.M.U. C.M.U. FRAME FRAME 2500# FASTENERS 2- HETA20'S GIRDER TO BOND BEAM H/I WITH 5/8" THREADED ROD MGT TO INVERTED HTT22 ON POST MGT TO BOND BEAM 3500# LOADS UPLIFT 1680# 2900# MIN 2" SIDE COVER TO EDGE OF SLAB ABU44/ABU66 POST TO SLAB/ BOND BEAM 2-MTS12's BEAM TO POST1 CONNECTORS Strong-TieSIMPSON SIMPSON Strong-Tie CONNECTORS WOOD TRUSS/RAFTER TO WOOD FRAMING = (1) MTS12 WOOD TRUSS/RAFTER TO C.M.U. = (1) HETA20 WOOD TRUSS TO WOODTRUSS = (1) HUS26 * UNLESS OTHERWISE NOTED CONVENTIONAL FRAMED JOINTS = (1)- A35A 2-PLY GIRDER TRUSS/BEAM TO C.M.U. = (2) HETA20 GIRDER TRUSS/BEAM TO WOOD FRAMING = (2) HTS20(2-PLY) WOOD GIRDER TO WOOD GIRDERTRUSS2PLY TYPICAL = (1) HGUS48 U-595# R- 7890# U-840# U- 1390# U-1680# LOADS U-1810# U-2500# FASTENERS 10-10dx1 1/2 14-10dx1 1/2 14-16d 28-16d 12-16d 58-16d 12-8dx1 1/2 U- 3415# R- 10000# R-595# FOR MISSED (1)HETA20 USE (1) HTSM16 (3) LSTA24 MAY BE USED IN LIEU OF (2) HTS20 OR (3)- CS16 STRAPS SYP SPF U-730# U-1460# 1-U-1175#1- U-1020# 2-U-2000#2- U-1800# 4-1/4" X 2 1/4" TAPCONS & 10 - 10D'S PER STRAPFOR MISSED (2)HETA20 USE (2) HTSM16 U-510# R-510# CONVENTIONAL FRAMING SPECS. CF 1- MTS12/ H25.A RAFTER TO BRG. 1- A35A CLIP RAFTER TO RIDGE 1- H2.5A RAFTER TO HEEL PURLIN TO TRUSS / RAFTER BELOW 2- 1/4" X 5" WOOD LOC SCREWS HEEL PURLIN 2- 2" X 6" SPRUCE PURLINS 2" X 6" SYP #2 JOISTS 24" O.C. 2" X 6" SYP #2 RAFTERS 24" O.C. 2" X 8" SYP #2 RIDGE, HIP & VALLEY DESIGN REQUIREMENTS: A. FLOORS LIVE LOAD IS 40 PSF,BALCONIES, DECKS, STAIRS, LIVE LOAD IS 60 PSF. B. ROOF LIVE LOAD IS 30 PSF CONSTRUCTION TYPE V-B NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS OF THE 2023 FLORIDA BUILDING CODE RESIDENTIAL 8TH EDITION PER ASCE 7-16 1. DESIGN WIND SPEED - V asd 108MPH/ V ult - 140MPH 2. RISK FACTOR II 3. WIND EXPOSURE - CATEGORY (C) 4. INTERNAL PRESSURE COEFFICIENT- (ASCE 7-16) ENCLOSED BUILDINGS= 0.18 HEIGHT AND EXPOSURE ADJUSTMENT COEF.- (+1.26) PER FBCR 2023 8TH EDITION R301.2(3) 5. COMPONENTS AND CLADDING : PER FBCR 2023 8TH EDITION R301.2(2) SEE WINDOW AND DOOR REQUIREMENTS S1 1/4" = 1'-0" REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES LP HANDYMAN LLCPEACH AVENUESanford, Fl. 327711- HETA20 (TYP.) EJ7 EJ7 A3 A2 CJ1 CJ3 CJ1 CJ3 CJ5 CJ5 H J 7 3 3 EJ7 EJ7 EJ7 EJ7 EJ7 EJ7 CJ1 CJ3 CJ1CJ3 CJ5 CJ5 HJ7A1 A4 A5 A5 A5 A5 A5 A5 A5 A5 A5 A5 A5 EJ7 1- H2.5A (TYP.) EJ7 EJ7 A9 CJ1 CJ3 CJ1 CJ3 CJ5 CJ5 HJ73 3 EJ7 EJ7 EJ7 EJ7 EJ7 EJ7 CJ1 CJ3 CJ1CJ3 CJ5 CJ5 HJ7A1 EJ7 A6 A6 A6 A6 A6 A7 A8 ODD SPACE CJ1 CJ3 CJ1CJ3 HJ4 CF EJ7 EJ7EJ7 1- HETA20 (TYP.) 1- HETA20 (TYP.) 1- HETA20 (TYP.) 1- HETA20 (TYP.) 1- HETA20 (TYP.) 1- MTS12 (TYP.) 1- MTS12 (TYP.) 3 3 3 HUS28-2 HUS26 (TYP.) EJ3 EJ3 EJ3 2 2 HUC48 HUC5.583- 2 X 10 SYP#2 3- 2 X 10 SYP#2 W/ 6 X 6 P.T POSTW/ 6 X 6 P.T POST DETAILS 2 2 29'-8"(2) 2"X12" AND BOTTOM OF ONE WALL STUD AT EACH SIDE OF OPENINGS. ** ANY ALLOWABLE HEADERS THAT EXCEED THE MAXIMUM SPAN SHALL BE THREE12"2x6 SOUTHERN PINE 2x8 SOUTHERN PINE 2x8 SOUTHERN PINE 2x8 SPRUCE FIR 2x8 SPRUCE FIR 16" 12" 12" 16" THREE THREE THREE THREE SP4 OR USP SPT4 @ EA. JACK STUD. NOTED ON THE ROOF PLAN. * SIMPSON LSTA 12 OR USP LAST12 WITH SIMPSON PROVIDE 1 SIMPSON SP4 OR USP SPT4 @ THE TOP # OF ROWSSIZE, #2 GRADE 2x6 SOUTHERN PINE 2x6 SPRUCE FIR 2x6 SPRUCE FIR 2x6 SPRUCE FIR 2x4 SOUTHERN PINE 2x4 SOUTHERN PINE 2x4 SPRUCE FIR 2x4 SPRUCE FIR 2x4 SPRUCE FIR 2x4 SPRUCE FIR 16" 12" 16" 16" 12" THREE THREE TWO NONE THREE 16" 16" 12" 16" 16" TWO THREE THREE ONE NONE LIMITING HEIGHT OF STUDS SPACING O.C.BLOCKING 19'-8" 22'-4" 24'-0" 21'-0" 18'-0" 17'-0" 16'-0" 14'-4" 15'-0" 9'-0" 12'-0" 13'-4" 14'-0" 10'-0" 8'-0" HEIGHT MAX #2 S.Y.P. HEADER (2) 2"X6" (2) 2"X8" (2) 2"X10" SIZE HEADER STUD(S) @ EACH END LOAD BEARING WALLS HEADER/STUD/STRAP CHART MAXIMUM 5'-1" 8'-2" 6'-0" SPAN 1 2 1 1 2 1 FULL LENGTH STUDS @ EACH END STRAP(S) AT EACH END OF 1 2 1 HEADER (3) STUDS IN A WALL MAY BE USED IN LIEU OF 4x4 P.T. POST TO MAX REACTION OF 4600# 4x4 PARRALM POST MAY BE USED IN LIEU OF 4x4 P.T. POST NOTE: LSTA 24 STUDS TO RIM @ BOTTOM PLATE USE @ 2 STORY IN LIEU SP1/SP4 FULL LENGTH MID-WALL BLKG. SP2 - 6-10D/6-10D LSTA12 10-10D SP4 - 6-10DX1.5 TYPICAL FRAMING AND CONNECTIONS FOR OPENINGS P.T. SILL PLATE SP4/SP6/SP8 RSP4 EA. STUD NAIL PER 1/2" ANCHOR BOLT SCHEDULE (OR 2 ON 1 SIDE) EA. SIDE OF STUDS HEADER STUDS CONT. SP1/SP4/SP6/SP8 AT 32" O.C. RAFTER OR TRUSS AT CUT TOP PLATESTUD IS REQUIRED UNDER BEARINGCUT TOP PLATE AS NEEDEDALT SP1 - 6-10D/4-10D STUDSCRIPPLE MIN. DBL. 2x8 HDR.FOF PLUMBING STACKDOUBLE TOP PLATE TRUSS (OR RAFTER) STUD / PLATE LSTA 12 SP2/SP4 WALL STUDS LSTA 12 OTHERWISE NOTED 2-2X12 HEADER UNLESS (2) MTS12 TO (3) STUDS W/ MIN TYPICAL GIRDER OR POST TRUSS CONNECTOR SP2/ SP4/SP6/SP8 AT 32" O.C. 1/2"X8" ANCHOR BOLT @ OR 5 /8" x6" WEDGE ANCHORS MAX 6" FROM HEADER STUDS AND 32" O.C. TYPICAL RSP4 EA. STUD SP4/SP6/SP8 19. GARAGES WITH HABITABLE ROOMS ABOVE SHALL HAVE 5/8" TYPE "X" DRYWALL CEILING 20. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM No. 26 GAGE(0.48MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. GENERAL NOTES 1. ALL ROOF AND FLOOR JOIST, BEAMS/HEADERS TO BE MIN. SOUTHERN YELLOW PINE #2 ROOF, FLOORS AND BEAM FRAMING WALLS TO BE SPRUCE #2 MINIMUM. MAXM. C. OF 19% EXTERIOR LUMBER OR TOUCHING CONCRETE TO BE PRESSURE TREATED. CCA. 40 MIN. 2. PROVIDE ADEQUATE BRACING AND BRIDGING TO TRUSSES TO RESIST WIND AND OTHER LATERAL FORCES 3. ALL GALVANIZED STEEL FLASHING TO BE ASTM A 653/D-224 G-90 ZINC COATED MIN 26 GA. 4. PRE-PAINTED DRIP EDGE TO BE ASTM A 755 6. VENTILATION OF ATTIC-RATIO TO BE NOT LESS THAN 1/ 150 OF FREE VENTED AREA/ CEILING PER FBC 2023 8TH EDITION CHAP R806 BUILDER TO VERIFY LOCATION 7. SECURE CONDENSER UNIT WITH 1 /4"x3" TAPCONS @8"O.C. MAX AND (2) AT CORNERS. 8. PROVIDE DRIP EDGE AT EAVES AND GABLES OVERLAP A MIN OF 2" AND FASTEN @ 8' O.C. 9. 1/ 4" MAX GAP BETWEEN DOOR JAMBS AND ROUGH OPENINGS. SCREWS TO PENETRATE STUDS 1-1/ 2" SEE MANUF. SPECS. 10. STUCCO TO BE 5 /8" OVER CMU OR 7 /8" ON METAL LATHE OVER WOOD 11. WINDOW CONTRACTOR TO VERIFY ALL TEMPERED WINDOW LOCATIONS PER FBC 2023 8TH EDITION SEC. R308 12. (3) STUDS IN A WALL MAY BE USED IN LIEU OF 4x4 PT POST. MAX REACTION OF 4600# 5. CONTRACTOR TO VERIFY W/ WINDOW AND DOOR SUPPLIER THAT ALL BEDROOMS HAVE REQUIRED EGRESS OPENINGS PRIOR TO INSTALLATION 16. ATTIC ACCESS REQ. 22"x36" W/ SWITCHED LIGHT 17. 1" DOOR CUT FOR AIR RETURN 18. 1-3/8" SOLID CORE DOOR REQUIRED BETWEEN GARAGE AND LIVING W/ AUTO CLOSER 2-#5 REBAR PRECAST CONCRETE SEE ELEVATIONS FINISH OR STRUC BLOCK 5/8" STUCCO 8"x16" CONC. BLOCK WINDOW SILL MARBLE SILL #5 DOWEL W/ LAP 25" MIN.LAP FILLED CELLS (SEE FLOOR PLAN) ASSUMED GRADE 16"CLEAN, COMPACTED WALL SECTION ONE STORY BLOCK TERMITE TREATED FILL DETAILS. SEE FOUNDATION SLAB W/ 6x6, 10/10 W.W.M. BARRIER 6 MIL VAPOR OR FIBERMESH R-4.1 INSULATION BASE BOARD P.T. 1x2 FURRING STRIPS TYP. CONC. P.T. 1x4 AT SILL AND JAMBS 12" MIN. 6.5" MIN. W/ 1 1/4" GALV ROOFING NAILS GALV METAL DRIP EDGE ASTM A527 CONT BEAD ROOFING MASTIC 1-HETA20 TYPICAL 1x2 P.T. 1x6 FASCIA OVER 2x4 SUB-FASCIA RETURN TEXTURED CEMENTITIOUS FIN. @ ALUM. FRAMED WINDOW SIZE OF WINDOWS VARY TYPE, CONFIGURATION AND REFER TO PLANS AND ELEVATIONS HEAD AND JAMB BEYOND JAMB ON P.T. 1x6 - EXTEND 8" LINTEL WITH 1- #5 8" CONCRETE PRECAST EACH SIDE 1/2" GYPSUM BOARD WALL FINISH BEYOND REBAR REBAR MIN.25" LAP W/ CONC. & 1 #5 8" LINTEL BLOCK REINF. 1/2" GYP. CEILING BRD. OR 5/8" DRYWALL ALUM. SOFFITPERFORATED 12 SEE ELEV. R-30 INSULATION 6" 0.C. OVER 15# FELT(ASTM D226 OR D4869 TYPE 1 FIBERGLASS SHINGLE ASTM D3161 FOR ARCH SHINGLES (8) 1 1/4" GALV ROOFING NAILS PER 3-TAB (6) 1 1/4" GALV ROOFING NAILS OVER 19/32" O.S.B. D1 N.T.S. REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES AND SEE MANUFACTURERS SPECS PRESSURE TREATED GARAGE DOOR GARAGE DOOR JAMB 8" CMU N.T.S. GARAGE DOOR TRACK 1/2" RND. X 8" LONG A.B. @ TOP PRESSURE TREATED 2X6 WOODJAMB ANCHOR TO BLOCK WITH BOTTOM & MIDPOINT CELLS PER PLAN # 5 VERTICAL GROUTED CMU 8" CMU 1X2 TRIM FOR WINDOW TO BUCK ATTACHMENT WINDOW JAMB 8" CMU N.T.S. IF 1 1/2" BUCK IS USED FOLLOW TAPCON NOTE 6" FROM EDGE AND 12" O.C. THRU DOOR FRAMEAND 1 1/4" INTO PRECAST PENETRATION INTO C.M.U. MASONRY WITH TAPCONSANCHOR DOOR JAMBS TO 6" FROM EDGE AND 12" O.C. THRU WINDOW FRAME AND 1 1/4" INTO PRECAST PENETRATION INTO C.M.U. 1/4 RND. X MIN 2" MASONRY WITH TAPCONSANCHOR WINDOW BUCK TO ALUMINUM/ VINYLWINDOW CONCRETE SILL BELOW THRESHOLD BELOW DOOR FRAME TO BLOCK EXTERIOR DOOR PRESSURE TREATED SHIM TYPICAL # 5 VERTICAL 8" CMU GROUTED CMU TYPICAL # 5 VERTICAL CONT. CAULK BEAD PRESSURE TREATED SHIM GROUTED CMU 8" CMUFOR WINDOW TO BUCK ATTACHMENTAND SEE MANUFACTURERS SPECSIF 1 1/2" BUCK IS USED FOLLOW TAPCON NOTE JAMB AT EXTERIOR DOOR 1/2" DRYWALL N.T.S. CONT. CAULK BEAD SILL BELOW1/4 RND. X MIN 2" 1/2" DRYWALL SECURE CONDENSOR UNIT AS SHOWN- W/ 2 - 3/8"x1 7/8" WEDGE ANCHORS (1) - 3/8" x 1 - 7/8" WEDGE ANCHORS IN GALV. 1"x4" "L" BRACKET TO PAD & (3) -#10 GALV TEX SCREW TO SHROUD A/C CONDENSOR UNIT (1) - 3/8" x 1 - 7/8" WEDGE ANCHORS IN GALV. 1"x4" "L" BRACKET TO PAD & (3) -#10 GALV TEX SCREW TO SHROUD 6" THICK CONCRETE PAD SHROUD COVER AND PENETRATE ROOF SHEATHING 3/4" MIN (6) PER SHINGLE FASTENER SHALL BE MIN 12 GAUGE SHANK W/ 3/8" HEAD SHINGLE-SHALL COMPLY WITH ASTMD225 OR ASTMD3462 PER MANUF. SPECS 1/2" CDX PLYWOOD OR 7/16" OSB FOR 7/16 OSB 24" MAX SPAN BLOCK AS NEEDED WALL SHEATHING 6" O.C. EDGES & 12" O.C. INTERIOR 2.5"X0.131" RING SHANK GUN NAILS ZONE 3 EDGES @ TRUSSES 4" O.C. AND INTERMEDIATE TRUSSES 4" O.C. ZONE 2 EDGES @ TRUSSES 4" O.C. AND INTERMEDIATE TRUSSES 4" O.C. ZONE 1 EDGES @ TRUSSES 6" O.C. AND INTERMEDIATE TRUSSES 6" O.C. 1 2 1 2 2 2 ROOF NAILING PATTERN 4'-0" 4'-0" 4'-0" 3 4'-0" 3 5'-0"VALLEY3VALLE Y 1 RIDGE 1 RIDGE3 22 ROOF EDGE 1 2 2 1 HI P 2 1 HIP 2 BUILDING WIDTH19/32 (MIN.) ROOF SHEATHING ROOF SHEATHING LAYOUT AND DIAPHRAGM BLOCKING BUILDING LENGTH TOP CHORD BLOCKING @ 4'-0" O.C. MAX.IN FIRST 2 FRAMING SPACES @ EA. END ROOF EDGER803.2.3.1 Sheathing fastenings: Wood structural panel sheathing shall be fastened to roof framing in accordance with Table R803.2.3.1. Where the sheathing thickness is 15/32 inches and less, sheathing shall be fastened with ASTM F1667 RSRS-01 (23/8" × 0.113") nails. Where the sheathing thickness is greater than 15/32 inches, sheathing shall be fastened with ASTM F1667 RSRS-03 (21/2" × 0.131") nails or ASTM F1667 RSRS-04 (3" × 0.120") nails. RSRS-01, RSRS-03 and RSRS-04 are ring shank nails meeting the specifications in ASTM F1667. SHINGLES PLATE SILL FROM EDGE AND 32" 0.C.6" MAX DISTANCEANCHOR BOLTS GRADE LINE GRADE LINE FOUNDATION LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771 2 2 FLASHING CORNER PATCH NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS 3. MECHANICALLY FASTEN AS NECESSARY SILL PLATE (SEE DETAIL B FOR OPTIONS) FLASHING TIE-IN WITH WEATHER RESISTIVE BARRIER: 1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH FLASHING TO FORM WATER SHEDDING LAPS 2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW FOR FLASHING INSTALLATION 4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER 5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE 1 1 FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE EXTERIOR SHEATHING 5 4 4 2 WEATHER RESISTIVE BARRIER 2 SEE NOTE #2 NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE 3. INSTALL SILL FLASHING AS SHOWN ABOVE 4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT 5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS WALL SHEATHING SILL PLATE WOODEN SIDING FLASHING OPTION - A DO NOT FLASH OVER BOTTOM NAILING FLANGE SILL PLATE NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE 3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS 4. INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS FLASHINGFLASHING FLASHINGWEATHER RESISTIVE BARRIER TAPE 2 (ASSEMBLED WINDOW ) HEAD FLASHING TIE-IN INSTRUCTIONS: 1. CUT, FOLD UP & TEMPORARILY SECURE WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW FOR FLASHING INSTALLATION 2. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER 3. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL WITH TAPE WEATHER RESISTIVE BARRIER FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE MECHANICALLY FASTEN AS NECESSARY IN CORNERS THROUGH FLASHING 1 EXTERIOR SHEATHING FLASHING NOTE: 7/ 8" STUCCO ON METAL LATHE ON 15 LB FELT AND OVER 2ND LAYER OF 15 LB FELT OR ONE LAYER OF FELT ON HOUSE WRAP 7/ 16" O.S.B. SHEATHING OR 1/ 2" PLYWOOD 2023 FBC RESIDENTIAL 8TH EDITION FLASHING APPROVED CORROSION-RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION-RESISTANT FLASHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS IN SUCH A MANNER AS TO BE LEAKPROOF, EXCEPT THAT SELF-FLASHING WINDOWS HAVING A CONTINUOUS LAP OF NOT LESS THAN 1 1/8 INCHES (28mm) OVER THE SHEATHING MATERIAL AROUND THE PERIMETER OF THE OPENING, INCLUDING CORNERS, DO NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. UNDERLAYMENT APPLICATION. UNDERLAYMENT SHALL BE INSTALLED USING ONE OF THE FOLLOWING METHODS: 1. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE I OR TYPE II OR ASTM D 4869, TYPE II OR TYPE IV OR ASTM D 6757 AND SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT FELT PARALLEL TO AND STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), AND FASTENED WITH A 1-INCH (25 MM) ROUND PLASTIC CAP, METAL CAP NAILS OR NAILS AND TIN-TABS ATTACHED TO A NAILABLE DECK WITH ONE ROW IN THE FIELD OF THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12 INCHES (305 MM) O.C., AND ONE ROW AT THE OVERLAPS FASTENED 6 INCHES (152 MM) O.C. SYNTHETIC UNDERLAYMENT SHALL BE FASTENED IN ACCORDANCE WITH THIS SECTION AND THE MANUFACTURER’S RECOMMENDATIONS. 2. FOR ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR GREATER. UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE II OR ASTM D 4869, TYPE IV OR ASTM D 6757 AND SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES (51 MM), FASTENED WITH 1-INCH (25 MM) ROUND PLASTIC CAP, METAL CAP NAILS OR NAILS AND TIN-TABS ATTACHED TO A NAILABLE DECK WITH TWO STAGGERED ROWS IN THE FIELD OF THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12 INCHES (305 MM) O.C., AND ONE ROW AT THE OVERLAPS FASTENED 6 INCHES (152 MM) O.C. SYNTHETIC UNDERLAYMENT SHALL BE FASTENED IN ACCORDANCE WITH THIS SECTION AND THE MANUFACTURER’S RECOMMENDATIONS END LAPS SHALL BE OFFSET BY 6 FEET (1829 MM). 3. AS AN ALTERNATIVE, THE ENTIRE ROOF DECK SHALL BE COVERED WITH AN APPROVED SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET MEETING ASTM D 1970 OR AN APPROVED SELF-ADHERING SYNTHETIC UNDERLAYMENT INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 2x8 SYP ROOF RAFTER TOPS. VALLEY FLASHING PER R903.2 TYP. A35/H2.5 EA. END OF RAFTER (2) 12d NAILS STUDS INTO RAFTER FOR RAFTERS UNDER 8'-0" USE MINIMUM 2- 12D NAILS PER CONNECTION IN LIEU OF CLIP A35/H2.5 EA. STUD TO PURLIN PRE-ENG'RED CONVENTIONAL FRAME ROOF VALLEY DETAIL TRUSSES 2x4 PURLINS TO TRUSS BELOW MTS12 48" O.C. 2x6 RAFTERS STUDS 48" O.C. w/ 2x4 VERTICAL24" O.C. RIDGE UNDER VALLEY ROOF SHEATHING SHEATHING CONT. AT VALLEY UNDER VALLEY ROOF SHEATHING 2x8 SPRUCE FOR STUD SPACING SEE FRAME WALL ON MASONRY SIDE & 32" O/C 8" CMU SP1 @ 32"O/C SP2 @ 32" O/C 3" 1/2" X 8" AB EA WALL HT CHART 8" TIE BM BTM EA STUD OPTIONAL H5 TOP & 1/2" DRYWALL SINGLE STORY INT BRNG WALL SECTION CLEAN, COMPACTED TERMITE TREATED FILL 16" 8" BARRIER (2) #5 RE-BAR W/ 25" MIN. LAP 3" MIN COVER 6 MIL VAPOR SP1/SP4 @ 32" O.C. 32" O.C. w/ 2" SQ. WASHER 1/2" x 8" ANCHOR BOLTS 2X4 P.T. PLATE OR 5/8 X 6" WEDGE ANCHORS STUD WALL SP4/SP2 32" O.C. 16" O.C. 2X4 (1) H25/MTS12 TRUSS FOR CONNECTION SEE TRUSS PLAN TO PLATE DOUBLE TOP PLATE 1/2" DRYWALL SP2 CLIP EACH STUD MASONRY CONC BLK VERTICAL WALL REINFORCING FOOTING DOWEL IS NOT GROUT LIFT > 5 FT. UNLESS CLEANOUT REQUIRED FOR WALL SYSTEM REBAR FOOTING W/ HORIZ. REQUIRED 25" LAP MIN 3" COVER6" HOOK FF GROUTED CELL VERTICAL DOWEL IN TIE TO HORIZ. BAR 6" HOOK 1 1/2" MIN. COVER LINTEL BEAM BREAK DETAIL REINF. 8" CMU TOP OF WALL LINTEL & VERTICAL 1 #5 W/ 25" LAP @ 8" CMU MIN. @ CORNERS TYP. REBAR LAP GROUTED CELL W/ #5 DOWEL ALL LAPS 25" #5 CORNER BAR 4" VENT PIPE THRU LINTEL FORM BDS 4" PVC VENT PIPE TOP VIEW POURED SIDE VIEW CONC LINTEL #5 REBAR U BLOCK FORM BDS C.M.U. COLUMN OR WALL TO BEAM DETAIL VERT. IN FILLED CELL CMU COLUMN OR WALLW 1# 5 HUC HANGER BEAM SEE FRAMING PLAN 2-2x4 PLATES INTERIOR KNEEWALL OPTION 1-LSTA 24 @ 32" O.C. KNEEWALL TO WALL BELOW INTERIOR KNEEWALL OPTION AND R905 FRC 2004 WC WC WC WC 60" 21"21" 15"30"30" TUB CLEARANCE CLEARANCE COMPARTMENT OR 5/8" DRYWALL 1/2" GYP. CEILING BOARD. DETAILS D2 N.T.S. REVISIONSJOB NO. P9559 DRAWN BY: TKP DATE: 12/18/2021 SCALE: KLP DESIGN SERVICES LP HANDYMAN LLCPEACH AVENUESanford, Fl. 32771