08.04.21 Fire Sprinkler Hydraulic Calculations 3823-3843 Hampton Chase Lane (2)
HYDRAULIC CALCULATIONS for LANDINGS AT RIVERBEND TOWN HOMES Building 4 Orlando, FL WAFS JOB #99148/99763 May 20, 2021 WAYNE AUTOMATIC FIRE SPRINKLERS, INC. 222 CAPITOL CT. - OCOEE, FL 34761 TEL (407) 656-3030 or FAX (407) 656-8026 Wayne Automatic Fire Sprinkler 222 Capitol Ct. Ocoee, FL 34761 (407) 656-3030 Job Name : Landings at Riverbend Town Homes DA1 Sheet Number : FP2.1 Location : Building 4 Design Area : DA1 Contract : 99148 Data File : DA1 Building 4 Unit 1680 2nd Floor Master Bedroom.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 1 Landings at Riverbend Town Homes DA1 Date 05/20/21 HYDRAULIC CALCULATIONS for Project name:Landings at Riverbend Town Homes Location:Building 4 Drawing no:FP2.1 Contract number:99148 Date:05/20/21 Design Remote area number:DA1 Remote area location:Unit 1680 2nd Floor Master Bedroom Occupancy classification:NFPA 13D Density:0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler:400 - SqFt Type of sprinklers calculated:Reliable Residential Pendents R3516 4.9K No. of sprinklers calculated:1 In-rack demand: - GPM Hose streams: - GPM Total water required (including hose streams):20.0 - GPM @ 45.0 - Psi Type of system:Wet Volume of dry or preaction system: - Gal Water supply information Date:04/02/21 Location:Intersection of Twin Flower and Sycamore Leaf Source:Sanford Water Name of contractor:Wayne Automatic Fire Sprinklers Address:222 Capitol Ct., Ocoee, FL 34761 Phone number:(407) 656-3030 Name of designer:LaRonn Jones Authority having jurisdiction:City of Sanford Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 2 Landings at Riverbend Town Homes DA1 Date 05/20/21 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 100 200 300 400 500 600 700 800 900 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 54 C2 - Residual Pressure: 38 C2 - Residual Flow : 964 D1 - Elevation : 6.930 D2 - System Flow : 20.024 D2 - System Pressure : 44.965 Hose ( Demand ) : _______D3 - System Demand : 20.024 Safety Margin : 9.022 D1 D2 Water Supply Curve Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 3 Landings at Riverbend Town Homes DA1 Date 05/20/21 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 B Butterfly Valve (Globe) 0 0 2 2 2 4 8 6 0 5 974192100000 E NFPA 13 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 111122333457911131719212428 G NFPA 13 Gate Valve 00000111122345678101113 L NFPA 13 Long Turn Elbow 1122234556891316182427303440 T NFPA 13 Tee Branch 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 U *CPVC 90' Elbow Tyco 0456791213000000000000 V *CPVC Tee Branch Tyco 03568101215000000000000 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 4 Landings at Riverbend Town Homes DA1 Date 05/20/21 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 54.0 38 964.0 53.988 20.02 44.965 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes S1 18.0 4.9 16.7 20.02 0.05 400 L1 18.33 18.32 M1 18.33 20.52 M3 18.33 23.41 201 18.33 24.81 101 9.67 31.22 M4 9.67 32.1 TOR 9.67 32.91 R1 2.0 36.38 BASR 1.0 36.86 UG33 -3.0 38.71 UG34 -3.0 38.86 BF2 -3.0 39.4 BF1 -3.0 46.03 UG35 -3.0 47.12 UG5 -3.0 47.13 UG16 -3.0 47.13 UG7 -3.0 47.12 UG28 -3.0 47.12 UG24 -3.0 47.12 UG8 -3.0 47.12 UG20 -3.0 47.12 UG9 -3.0 47.12 UG10 -3.0 47.12 UG11 -3.0 47.12 UG12 -3.0 47.13 UG4 -3.0 47.13 UG3 -3.0 47.13 UG2 -3.0 47.13 UG1 -3.0 47.13 TEST 2.0 44.97 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 5 Landings at Riverbend Town Homes DA1 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf S1 18 4.90 20.02 0.75 U 4.0 1.420 150 16.700 to V 3.0 7.000 -0.143 L1 18.330 20.02 0.874 8.420 0.2100 1.768 Vel = 10.71 0.0 L1 20.02 18.325 K Factor = 4.68 L1 18.330 20.02 0.75 10.460 150 18.325 to 0.0 M1 18.330 20.02 0.874 10.460 0.2099 2.196 Vel = 10.71 0.0 M1 20.02 20.521 K Factor = 4.42 M1 18.330 20.02 0.75 V 3.0 10.750 150 20.521 to 3.000 0.0 M3 18.330 20.02 0.874 13.750 0.2099 2.886 Vel = 10.71 M3 18.330 0.0 0.75 U 4.0 2.670 150 23.407 to 4.000 0.0 201 18.330 20.02 0.874 6.670 0.2100 1.401 Vel = 10.71 0.0 201 20.02 24.808 K Factor = 4.02 201 18.330 20.02 0.75 U 4.0 8.670 150 24.808 to 4.000 3.751 101 9.670 20.02 0.874 12.670 0.2099 2.659 Vel = 10.71 0.0 101 20.02 31.218 K Factor = 3.58 101 9.670 20.02 0.75 V 3.0 1.210 150 31.218 to 3.000 0.0 M4 9.670 20.02 0.874 4.210 0.2100 0.884 Vel = 10.71 M4 9.670 0.0 1.25 U 6.0 31.170 150 32.102 to 6.000 0.0 TOR 9.670 20.02 1.394 37.170 0.0216 0.803 Vel = 4.21 0.0 TOR 20.02 32.905 K Factor = 3.49 TOR 9.670 20.02 1.5 Z 5.828 7.670 150 32.905 to 5.828 3.322 R1 2 20.02 1.598 13.498 0.0111 0.150 Vel = 3.20 R1 2 0.0 1.5 B 2.0 1.000 120 36.377 to 2.000 0.433 BASR 1 20.02 1.61 3.000 0.0163 0.049 Vel = 3.16 BASR 1 0.0 1.5 U 7.0 4.000 150 36.859 to 7.000 1.732 UG33 -3 20.02 1.598 11.000 0.0111 0.122 Vel = 3.20 0.0 UG33 20.02 38.713 K Factor = 3.22 UG33 -3 20.02 2 U 9.0 31.330 150 38.713 to 9.000 0.0 UG34 -3 20.02 2.003 40.330 0.0037 0.149 Vel = 2.04 UG34 -3 0.0 2 2U 18.0 128.040 150 38.862 to 18.000 0.0 BF2 -3 20.02 2.003 146.040 0.0037 0.541 Vel = 2.04 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 6 Landings at Riverbend Town Homes DA1 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BF2 -3 0.0 2 3E 15.0 15.000 120 39.403 to Zik 0.0 15.000 6.482 * * Fixed Loss = 6.482 BF1 -3 20.02 2.067 30.000 0.0048 0.143 Vel = 1.91 BF1 -3 0.0 2 V 10.0 7.170 120 46.028 to 10.000 1.000 * * Fixed Loss = 1 UG35 -3 20.02 2.003 17.170 0.0056 0.096 Vel = 2.04 0.0 UG35 20.02 47.124 K Factor = 2.92 UG35 -3 20.02 8 T 43.857 233.920 150 47.124 to 43.857 0.0 UG5 -3 20.02 7.68 277.777 0 0.002 Vel = 0.14 0.0 UG5 20.02 47.126 K Factor = 2.92 UG35 -3 0.0 8 G 5.012 209.540 150 47.124 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 258.409 0 0.0 Vel = 0 0.0 UG6 0.0 45.825 K Factor = 0 UG5 -3 13.64 8 G 5.012 90.290 150 47.126 to 5.012 0.0 UG16 -3 13.64 7.68 95.302 0 0.0 Vel = 0.09 UG16 -3 0.0 8 G 5.012 199.710 150 47.126 to T 43.857 48.869 0.0 UG4 -3 13.64 7.68 248.579 0 0.0 Vel = 0.09 0.0 UG4 13.64 47.126 K Factor = 1.99 UG7 -3 0.0 8 G 5.012 225.000 150 47.124 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 273.869 0 0.0 Vel = 0 0.0 UG6 0.0 45.825 K Factor = 0 UG28 -3 0.0 6 G 3.834 205.625 150 47.124 to T 38.342 42.176 -1.299 UG6 0 0.0 5.86 247.801 0 0.0 Vel = 0 0.0 UG6 0.0 45.825 K Factor = 0 UG24 -3 0.0 6 223.670 150 47.124 to 0.0 UG28 -3 0.0 5.86 223.670 0 0.0 Vel = 0 0.0 UG28 0.0 47.124 K Factor = 0 UG24 -3 0.0 6 G 3.834 205.670 150 47.124 to T 38.342 42.176 0.0 UG11 -3 0.0 5.86 247.846 0 0.0 Vel = 0 0.0 UG11 0.0 47.124 K Factor = 0 UG8 -3 0.0 8 G 5.012 158.875 150 47.124 to T 43.857 48.869 0.0 UG7 -3 0.0 7.68 207.744 0 0.0 Vel = 0 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 7 Landings at Riverbend Town Homes DA1 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 UG7 0.0 47.124 K Factor = 0 UG20 -3 0.0 8 271.040 150 47.124 to 0.0 UG8 -3 0.0 7.68 271.040 0 0.0 Vel = 0 0.0 UG8 0.0 47.124 K Factor = 0 UG9 -3 0.0 8 24.580 150 47.124 to 0.0 UG20 -3 0.0 7.68 24.580 0 0.0 Vel = 0 0.0 UG20 0.0 47.124 K Factor = 0 UG10 -3 0.0 8 G 5.012 180.420 150 47.124 to 5.012 0.0 UG9 -3 0.0 7.68 185.432 0 0.0 Vel = 0 0.0 UG9 0.0 47.124 K Factor = 0 UG11 -3 0.0 8 G 5.012 225.000 150 47.124 to T 43.857 48.869 0.0 UG10 -3 0.0 7.68 273.869 0 0.0 Vel = 0 0.0 UG10 0.0 47.124 K Factor = 0 UG5 -3 6.39 6 2G 7.668 635.000 150 47.126 to T 38.342 46.010 0.0 UG12 -3 6.39 5.86 681.010 0 0.001 Vel = 0.08 UG12 -3 0.0 8 2G 10.025 512.830 150 47.127 to L 16.29 70.172 0.0 UG3 -3 6.39 7.68 T 43.857 583.002 0 0.001 Vel = 0.04 0.0 UG3 6.39 47.128 K Factor = 0.93 UG4 -3 13.64 8 2G 10.025 369.830 150 47.126 to T 43.857 53.882 0.0 UG3 -3 13.64 7.68 423.712 0 0.002 Vel = 0.09 UG3 -3 6.38 8 8F 90.221 180.625 150 47.128 to G 5.012 139.090 0.0 UG2 -3 20.02 7.68 T 43.857 319.715 0 0.001 Vel = 0.14 UG2 -3 0.0 8 2F 22.555 101.670 150 47.129 to T 43.857 66.412 0.0 UG1 -3 20.02 7.68 168.082 0 0.001 Vel = 0.14 UG1 -3 0.0 6 G 4.952 18.125 140 47.130 to L 14.855 19.807 -2.166 TEST 2 20.02 6.34 37.932 0 0.001 Vel = 0.20 0.0 TEST 20.02 44.965 K Factor = 2.99 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler 222 Capitol Ct. Ocoee, FL 34761 (407) 656-3030 Job Name : Landings at Riverbend Town Homes DA2 Sheet Number : FP2.1 Location : Building 4 Design Area : DA2 Contract : 99148 Data File : DA2 Building 4 Unit 1680 2nd Floor Hallway.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 1 Landings at Riverbend Town Homes DA2 Date 05/20/21 HYDRAULIC CALCULATIONS for Project name:Landings at Riverbend Town Homes Location:Building 4 Drawing no:FP2.1 Contract number:99148 Date:05/20/21 Design Remote area number:DA2 Remote area location:Unit 1680 2nd Floor Hallway Occupancy classification:NFPA 13D Density:0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler:256 - SqFt Type of sprinklers calculated:Reliable Residential Pendents R3516 4.9K No. of sprinklers calculated:2 In-rack demand: - GPM Hose streams: - GPM Total water required (including hose streams):26.4 - GPM @ 41.2 - Psi Type of system:Wet Volume of dry or preaction system: - Gal Water supply information Date:04/02/21 Location:Intersection of Twin Flower and Sycamore Leaf Source:Sanford Water Name of contractor:Wayne Automatic Fire Sprinklers Address:222 Capitol Ct., Ocoee, FL 34761 Phone number:(407) 656-3030 Name of designer:LaRonn Jones Authority having jurisdiction:City of Sanford Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 2 Landings at Riverbend Town Homes DA2 Date 05/20/21 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 100 200 300 400 500 600 700 800 900 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 54 C2 - Residual Pressure: 38 C2 - Residual Flow : 964 D1 - Elevation : 6.930 D2 - System Flow : 26.35 D2 - System Pressure : 41.174 Hose ( Demand ) : _______D3 - System Demand : 26.35 Safety Margin : 12.805 D1 D2 Water Supply Curve Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 3 Landings at Riverbend Town Homes DA2 Date 05/20/21 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 E NFPA 13 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 111122333457911131719212428 G NFPA 13 Gate Valve 00000111122345678101113 L NFPA 13 Long Turn Elbow 1122234556891316182427303440 T NFPA 13 Tee Branch 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 U *CPVC 90' Elbow Tyco 0456791213000000000000 V *CPVC Tee Branch Tyco 03568101215000000000000 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 4 Landings at Riverbend Town Homes DA2 Date 05/20/21 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 54.0 38 964.0 53.979 26.35 41.174 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes S2 18.0 4.9 7.0 12.96 0.05 256 S3 18.0 4.9 7.46 13.39 0.05 256 L2 18.33 7.17 L3 18.33 7.75 M1 18.33 7.78 M2 18.33 8.4 M3 18.33 9.07 201 18.33 11.4 101 9.67 19.57 M4 9.67 21.04 TOR 9.67 22.37 R1 2.0 25.94 BASR 1.0 32.4 UG33 -3.0 34.34 UG34 -3.0 34.59 BF2 -3.0 35.49 BF1 -3.0 42.17 UG35 -3.0 43.33 UG5 -3.0 43.33 UG16 -3.0 43.33 UG7 -3.0 43.33 UG28 -3.0 43.33 UG24 -3.0 43.33 UG8 -3.0 43.33 UG20 -3.0 43.33 UG9 -3.0 43.33 UG10 -3.0 43.33 UG11 -3.0 43.33 UG12 -3.0 43.33 UG4 -3.0 43.33 UG3 -3.0 43.33 UG2 -3.0 43.34 UG1 -3.0 43.34 TEST 2.0 41.17 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 5 Landings at Riverbend Town Homes DA2 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf S2 18 4.90 12.96 0.75 V 3.0 0.330 150 7.000 to 3.000 -0.143 L2 18.330 12.96 0.874 3.330 0.0940 0.313 Vel = 6.93 0.0 L2 12.96 7.170 K Factor = 4.84 S3 18 4.90 13.39 0.75 U 4.0 0.330 150 7.463 to 4.000 -0.143 L3 18.330 13.39 0.874 4.330 0.0995 0.431 Vel = 7.16 0.0 L3 13.39 7.751 K Factor = 4.81 L2 18.330 12.96 0.75 V 3.0 3.500 150 7.170 to 3.000 0.0 M1 18.330 12.96 0.874 6.500 0.0938 0.610 Vel = 6.93 0.0 M1 12.96 7.780 K Factor = 4.65 L3 18.330 13.39 0.75 V 3.0 3.500 150 7.751 to 3.000 0.0 M2 18.330 13.39 0.874 6.500 0.0997 0.648 Vel = 7.16 0.0 M2 13.39 8.399 K Factor = 4.62 M1 18.330 12.96 0.75 V 3.0 10.750 150 7.780 to 3.000 0.0 M3 18.330 12.96 0.874 13.750 0.0940 1.292 Vel = 6.93 0.0 M3 12.96 9.072 K Factor = 4.30 M2 18.330 13.39 0.75 V 3.0 3.750 150 8.399 to 3.000 0.0 M3 18.330 13.39 0.874 6.750 0.0997 0.673 Vel = 7.16 M3 18.330 12.96 0.75 U 4.0 2.670 150 9.072 to 4.000 0.0 201 18.330 26.35 0.874 6.670 0.3489 2.327 Vel = 14.09 0.0 201 26.35 11.399 K Factor = 7.80 201 18.330 26.35 0.75 U 4.0 8.670 150 11.399 to 4.000 3.751 101 9.670 26.35 0.874 12.670 0.3489 4.420 Vel = 14.09 0.0 101 26.35 19.570 K Factor = 5.96 101 9.670 26.35 0.75 V 3.0 1.210 150 19.570 to 3.000 0.0 M4 9.670 26.35 0.874 4.210 0.3487 1.468 Vel = 14.09 M4 9.670 0.0 1.25 U 6.0 31.170 150 21.038 to 6.000 0.0 TOR 9.670 26.35 1.394 37.170 0.0359 1.335 Vel = 5.54 0.0 TOR 26.35 22.373 K Factor = 5.57 TOR 9.670 26.35 1.5 Z 5.828 7.670 150 22.373 to 5.828 3.322 R1 2 26.35 1.598 13.498 0.0184 0.249 Vel = 4.22 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 6 Landings at Riverbend Town Homes DA2 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf R1 2 0.0 1.5 1.000 120 25.944 to 6.433 * * Fixed Loss = 6 BASR 1 26.35 1.61 1.000 0.0270 0.027 Vel = 4.15 BASR 1 0.0 1.5 U 7.0 4.000 150 32.404 to 7.000 1.732 UG33 -3 26.35 1.598 11.000 0.0185 0.204 Vel = 4.22 0.0 UG33 26.35 34.340 K Factor = 4.50 UG33 -3 26.35 2 U 9.0 31.330 150 34.340 to 9.000 0.0 UG34 -3 26.35 2.003 40.330 0.0061 0.248 Vel = 2.68 UG34 -3 0.0 2 2U 18.0 128.040 150 34.588 to 18.000 0.0 BF2 -3 26.35 2.003 146.040 0.0061 0.897 Vel = 2.68 BF2 -3 0.0 2 3E 15.0 15.000 120 35.485 to Zik 0.0 15.000 6.445 * * Fixed Loss = 6.445 BF1 -3 26.35 2.067 30.000 0.0080 0.239 Vel = 2.52 BF1 -3 0.0 2 V 10.0 7.170 120 42.169 to 10.000 1.000 * * Fixed Loss = 1 UG35 -3 26.35 2.003 17.170 0.0093 0.160 Vel = 2.68 0.0 UG35 26.35 43.329 K Factor = 4.00 UG35 -3 26.35 8 T 43.857 233.920 150 43.329 to 43.857 0.0 UG5 -3 26.35 7.68 277.777 0 0.002 Vel = 0.18 0.0 UG5 26.35 43.331 K Factor = 4.00 UG35 -3 0.0 8 G 5.012 209.540 150 43.329 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 258.409 0 0.0 Vel = 0 0.0 UG6 0.0 42.030 K Factor = 0 UG5 -3 17.95 8 G 5.012 90.290 150 43.331 to 5.012 0.0 UG16 -3 17.95 7.68 95.302 0 0.001 Vel = 0.12 UG16 -3 0.0 8 G 5.012 199.710 150 43.332 to T 43.857 48.869 0.0 UG4 -3 17.95 7.68 248.579 0 0.001 Vel = 0.12 0.0 UG4 17.95 43.333 K Factor = 2.73 UG7 -3 0.0 8 G 5.012 225.000 150 43.329 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 273.869 0 0.0 Vel = 0 0.0 UG6 0.0 42.030 K Factor = 0 UG28 -3 0.0 6 G 3.834 205.625 150 43.329 to T 38.342 42.176 -1.299 UG6 0 0.0 5.86 247.801 0 0.0 Vel = 0 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 7 Landings at Riverbend Town Homes DA2 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 UG6 0.0 42.030 K Factor = 0 UG24 -3 0.0 6 223.670 150 43.329 to 0.0 UG28 -3 0.0 5.86 223.670 0 0.0 Vel = 0 0.0 UG28 0.0 43.329 K Factor = 0 UG24 -3 0.0 6 G 3.834 205.670 150 43.329 to T 38.342 42.176 0.0 UG11 -3 0.0 5.86 247.846 0 0.0 Vel = 0 0.0 UG11 0.0 43.329 K Factor = 0 UG8 -3 0.0 8 G 5.012 158.875 150 43.329 to T 43.857 48.869 0.0 UG7 -3 0.0 7.68 207.744 0 0.0 Vel = 0 0.0 UG7 0.0 43.329 K Factor = 0 UG20 -3 0.0 8 271.040 150 43.329 to 0.0 UG8 -3 0.0 7.68 271.040 0 0.0 Vel = 0 0.0 UG8 0.0 43.329 K Factor = 0 UG9 -3 0.0 8 24.580 150 43.329 to 0.0 UG20 -3 0.0 7.68 24.580 0 0.0 Vel = 0 0.0 UG20 0.0 43.329 K Factor = 0 UG10 -3 0.0 8 G 5.012 180.420 150 43.329 to 5.012 0.0 UG9 -3 0.0 7.68 185.432 0 0.0 Vel = 0 0.0 UG9 0.0 43.329 K Factor = 0 UG11 -3 0.0 8 G 5.012 225.000 150 43.329 to T 43.857 48.869 0.0 UG10 -3 0.0 7.68 273.869 0 0.0 Vel = 0 0.0 UG10 0.0 43.329 K Factor = 0 UG5 -3 8.40 6 2G 7.668 635.000 150 43.331 to T 38.342 46.010 0.0 UG12 -3 8.4 5.86 681.010 0 0.003 Vel = 0.10 UG12 -3 0.0 8 2G 10.025 512.830 150 43.334 to L 16.29 70.172 0.0 UG3 -3 8.4 7.68 T 43.857 583.002 0 0.001 Vel = 0.06 0.0 UG3 8.40 43.335 K Factor = 1.28 UG4 -3 17.95 8 2G 10.025 369.830 150 43.333 to T 43.857 53.882 0.0 UG3 -3 17.95 7.68 423.712 0 0.002 Vel = 0.12 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 8 Landings at Riverbend Town Homes DA2 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf UG3 -3 8.40 8 8F 90.221 180.625 150 43.335 to G 5.012 139.090 0.0 UG2 -3 26.35 7.68 T 43.857 319.715 0 0.002 Vel = 0.18 UG2 -3 0.0 8 2F 22.555 101.670 150 43.337 to T 43.857 66.412 0.0 UG1 -3 26.35 7.68 168.082 0 0.002 Vel = 0.18 UG1 -3 0.0 6 G 4.952 18.125 140 43.339 to L 14.855 19.807 -2.166 TEST 2 26.35 6.34 37.932 0 0.001 Vel = 0.27 0.0 TEST 26.35 41.174 K Factor = 4.11 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler 222 Capitol Ct. Ocoee, FL 34761 (407) 656-3030 Job Name : Landings at Riverbend Town Homes DA3 Sheet Number : FP2.1 Location : Building 4 Design Area : DA3 Contract : 99148 Data File : DA3 Building 4 Unit 1680 1st Floor Common Area.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 1 Landings at Riverbend Town Homes DA3 Date 05/20/21 HYDRAULIC CALCULATIONS for Project name:Landings at Riverbend Town Homes Location:Building 4 Drawing no:FP2.1 Contract number:99148 Date:05/20/21 Design Remote area number:DA3 Remote area location:Unit 1680 1st Floor Common Area Occupancy classification:NFPA 13D Density:0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler:400 - SqFt Type of sprinklers calculated:Reliable Residential Pendents R3516 4.9K No. of sprinklers calculated:2 In-rack demand: - GPM Hose streams: - GPM Total water required (including hose streams):41.7 - GPM @ 48.2 - Psi Type of system:Wet Volume of dry or preaction system: - Gal Water supply information Date:04/02/21 Location:Intersection of Twin Flower and Sycamore Leaf Source:Sanford Water Name of contractor:Wayne Automatic Fire Sprinklers Address:222 Capitol Ct., Ocoee, FL 34761 Phone number:(407) 656-3030 Name of designer:LaRonn Jones Authority having jurisdiction:City of Sanford Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 2 Landings at Riverbend Town Homes DA3 Date 05/20/21 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 100 200 300 400 500 600 700 800 900 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 54 C2 - Residual Pressure: 38 C2 - Residual Flow : 964 D1 - Elevation : 2.889 D2 - System Flow : 41.723 D2 - System Pressure : 48.174 Hose ( Demand ) : _______D3 - System Demand : 41.723 Safety Margin : 5.778 D1 D2 Water Supply Curve Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 3 Landings at Riverbend Town Homes DA3 Date 05/20/21 Fitting Legend Abbrev.Name ½¾11¼1½22½33½456810121416182024 E NFPA 13 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 111122333457911131719212428 G NFPA 13 Gate Valve 00000111122345678101113 L NFPA 13 Long Turn Elbow 1122234556891316182427303440 T NFPA 13 Tee Branch 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 U *CPVC 90' Elbow Tyco 0456791213000000000000 V *CPVC Tee Branch Tyco 03568101215000000000000 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 4 Landings at Riverbend Town Homes DA3 Date 05/20/21 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 54.0 38 964.0 53.952 41.72 48.174 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes S4 8.67 4.9 16.7 20.02 0.05 400 S5 8.67 4.9 19.61 21.7 0.05 400 L4 9.67 17.11 L5 9.67 20.15 M4 9.67 23.62 TOR 9.67 26.74 R1 2.0 30.65 BASR 1.0 37.15 UG33 -3.0 39.35 UG34 -3.0 39.93 BF2 -3.0 42.03 BF1 -3.0 48.94 UG35 -3.0 50.31 UG5 -3.0 50.32 UG16 -3.0 50.32 UG7 -3.0 50.31 UG28 -3.0 50.31 UG24 -3.0 50.31 UG8 -3.0 50.31 UG20 -3.0 50.31 UG9 -3.0 50.31 UG10 -3.0 50.31 UG11 -3.0 50.31 UG12 -3.0 50.33 UG4 -3.0 50.32 UG3 -3.0 50.33 UG2 -3.0 50.33 UG1 -3.0 50.34 TEST 2.0 48.17 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 5 Landings at Riverbend Town Homes DA3 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf S4 8.670 4.90 20.02 0.75 V 3.0 1.000 150 16.700 to 3.000 -0.433 L4 9.670 20.02 0.874 4.000 0.2100 0.840 Vel = 10.71 0.0 L4 20.02 17.107 K Factor = 4.84 S5 8.670 4.90 21.70 0.75 V 3.0 1.000 150 19.610 to 3.000 -0.433 L5 9.670 21.7 0.874 4.000 0.2435 0.974 Vel = 11.60 0.0 L5 21.70 20.151 K Factor = 4.83 L4 9.670 20.02 0.75 14.500 150 17.107 to 0.0 L5 9.670 20.02 0.874 14.500 0.2099 3.044 Vel = 10.71 L5 9.670 21.70 0.75 4.250 150 20.151 to 0.0 M4 9.670 41.72 0.874 4.250 0.8162 3.469 Vel = 22.31 0.0 M4 41.72 23.620 K Factor = 8.58 M4 9.670 41.72 1.25 U 6.0 31.170 150 23.620 to 6.000 0.0 TOR 9.670 41.72 1.394 37.170 0.0840 3.124 Vel = 8.77 0.0 TOR 41.72 26.744 K Factor = 8.07 TOR 9.670 41.72 1.5 Z 5.828 7.670 150 26.744 to 5.828 3.322 R1 2 41.72 1.598 13.498 0.0432 0.583 Vel = 6.67 R1 2 0.0 1.5 1.000 120 30.649 to 6.433 * * Fixed Loss = 6 BASR 1 41.72 1.61 1.000 0.0640 0.064 Vel = 6.57 BASR 1 0.0 1.5 U 7.0 4.000 150 37.146 to 7.000 1.732 UG33 -3 41.72 1.598 11.000 0.0432 0.475 Vel = 6.67 0.0 UG33 41.72 39.353 K Factor = 6.65 UG33 -3 41.72 2 U 9.0 31.330 150 39.353 to 9.000 0.0 UG34 -3 41.72 2.003 40.330 0.0144 0.580 Vel = 4.25 UG34 -3 0.0 2 2U 18.0 128.040 150 39.933 to 18.000 0.0 BF2 -3 41.72 2.003 146.040 0.0144 2.101 Vel = 4.25 BF2 -3 0.0 2 3E 15.0 15.000 120 42.034 to Zik 0.0 15.000 6.347 * * Fixed Loss = 6.347 BF1 -3 41.72 2.067 30.000 0.0186 0.559 Vel = 3.99 BF1 -3 0.0 2 V 10.0 7.170 120 48.940 to 10.000 1.000 * * Fixed Loss = 1 UG35 -3 41.72 2.003 17.170 0.0218 0.374 Vel = 4.25 0.0 UG35 41.72 50.314 K Factor = 5.88 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 6 Landings at Riverbend Town Homes DA3 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf UG35 -3 41.72 8 T 43.857 233.920 150 50.314 to 43.857 0.0 UG5 -3 41.72 7.68 277.777 0 0.005 Vel = 0.29 0.0 UG5 41.72 50.319 K Factor = 5.88 UG35 -3 0.0 8 G 5.012 209.540 150 50.314 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 258.409 0 -0.001 Vel = 0 0.0 UG6 0.0 49.014 K Factor = 0 UG5 -3 28.42 8 G 5.012 90.290 150 50.319 to 5.012 0.0 UG16 -3 28.42 7.68 95.302 0 0.001 Vel = 0.20 UG16 -3 0.0 8 G 5.012 199.710 150 50.320 to T 43.857 48.869 0.0 UG4 -3 28.42 7.68 248.579 0 0.003 Vel = 0.20 0.0 UG4 28.42 50.323 K Factor = 4.01 UG7 -3 0.0 8 G 5.012 225.000 150 50.314 to T 43.857 48.869 -1.299 UG6 0 0.0 7.68 273.869 0 -0.001 Vel = 0 0.0 UG6 0.0 49.014 K Factor = 0 UG28 -3 0.0 6 G 3.834 205.625 150 50.314 to T 38.342 42.176 -1.299 UG6 0 0.0 5.86 247.801 0 -0.001 Vel = 0 0.0 UG6 0.0 49.014 K Factor = 0 UG24 -3 0.0 6 223.670 150 50.314 to 0.0 UG28 -3 0.0 5.86 223.670 0 0.0 Vel = 0 0.0 UG28 0.0 50.314 K Factor = 0 UG24 -3 0.0 6 G 3.834 205.670 150 50.314 to T 38.342 42.176 0.0 UG11 -3 0.0 5.86 247.846 0 0.0 Vel = 0 0.0 UG11 0.0 50.314 K Factor = 0 UG8 -3 0.0 8 G 5.012 158.875 150 50.314 to T 43.857 48.869 0.0 UG7 -3 0.0 7.68 207.744 0 0.0 Vel = 0 0.0 UG7 0.0 50.314 K Factor = 0 UG20 -3 0.0 8 271.040 150 50.314 to 0.0 UG8 -3 0.0 7.68 271.040 0 0.0 Vel = 0 0.0 UG8 0.0 50.314 K Factor = 0 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5 Wayne Automatic Fire Sprinkler Page 7 Landings at Riverbend Town Homes DA3 Date 05/20/21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf UG9 -3 0.0 8 24.580 150 50.314 to 0.0 UG20 -3 0.0 7.68 24.580 0 0.0 Vel = 0 0.0 UG20 0.0 50.314 K Factor = 0 UG10 -3 0.0 8 G 5.012 180.420 150 50.314 to 5.012 0.0 UG9 -3 0.0 7.68 185.432 0 0.0 Vel = 0 0.0 UG9 0.0 50.314 K Factor = 0 UG11 -3 0.0 8 G 5.012 225.000 150 50.314 to T 43.857 48.869 0.0 UG10 -3 0.0 7.68 273.869 0 0.0 Vel = 0 0.0 UG10 0.0 50.314 K Factor = 0 UG5 -3 13.30 6 2G 7.668 635.000 150 50.319 to T 38.342 46.010 0.0 UG12 -3 13.3 5.86 681.010 0 0.007 Vel = 0.16 UG12 -3 0.0 8 2G 10.025 512.830 150 50.326 to L 16.29 70.172 0.0 UG3 -3 13.3 7.68 T 43.857 583.002 0 0.001 Vel = 0.09 0.0 UG3 13.30 50.327 K Factor = 1.87 UG4 -3 28.42 8 2G 10.025 369.830 150 50.323 to T 43.857 53.882 0.0 UG3 -3 28.42 7.68 423.712 0 0.004 Vel = 0.20 UG3 -3 13.30 8 8F 90.221 180.625 150 50.327 to G 5.012 139.090 0.0 UG2 -3 41.72 7.68 T 43.857 319.715 0 0.007 Vel = 0.29 UG2 -3 0.0 8 2F 22.555 101.670 150 50.334 to T 43.857 66.412 0.0 UG1 -3 41.72 7.68 168.082 0 0.003 Vel = 0.29 UG1 -3 0.0 6 G 4.952 18.125 140 50.337 to L 14.855 19.807 -2.166 TEST 2 41.72 6.34 37.932 0.0001 0.003 Vel = 0.42 0.0 TEST 41.72 48.174 K Factor = 6.01 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.5