HomeMy WebLinkAbout3839 Hampton Chase Lane - 3-18-2021 - AC CalcsEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 43/18/2021 9:48 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction:581000 KB HomesLot154Bldg8Landings@Riverbend2201557GLN Street: City, State, Zip:, FL , Permit Number: Design Location:FL, Orlando County:Orange (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Attached 1 No 1557 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Dbl, U=0.36 90.00 ft² SHGC=0.22 Dbl, U=0.61 40.00 ft² SHGC=0.25 N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. Floor Over Other Space c. other (see details) R=0.0 727.00 ft² R=0.0 672.00 ft² R=158.00 ft² 10. Wall Types a. Frame - Wood, Exterior R=13.0 384.00 ft² b. Concrete Block - Int Insul, Exterior R=4.1 264.33 ft² c. Frame - Wood, Adjacent R=13.0 173.33 ft² 11. Ceiling Types a. Under Attic (Vented)R=30.0 885.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: 2nd Floor 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.000 ft. Area Weighted Average SHGC:0.229 Description Area Insulation Area Insulation Area Insulation Area 16. Credits Pstat 3 (130.0 sqft.) (821.7 sqft.) (885.0 sqft.) (1557.0 sqft.) Conditioned floor area below grade (ft²)0 a. Central Unit a. Electric Heat Pump k B t u / h r 28.4 SEER:15.00 Efficiency k B t u / h r Efficiency 28.4 HSPF:8.50 f t ² R 6 311.4 EF: 2.450 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area:0.083 Total Proposed Modified Loads: Total Baseline Loads: 33.88 38.75 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction:581000 KB Homes 1 Lot154Bldg8Landings@River Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 2 1557 3 New (From Plans) Attached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , , Orange 8/LANDINGS@RIVE 154 Lot Information Comment: Building Type:User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinterSummer CLIMATE 91 70 75 526 44 Medium41FL_ORLANDO_INTL_ARFL, Orlando______ Number Name Area Volume BLOCKS 1 Block1 1557 12964.9 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 1st Floor 727 6324.9 Yes 3 0 Yes Yes1Yes 2 2nd Floor 830 6640 No 1 3 Yes Yes1Yes #Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpacePerimeter 1 158 ft² 0.25 0 0.75______13Floor over Garage 13 - - - - - - - -2nd Floor 2 727 ft² 0.32 0 0.68______Slab-On-Grade Edge Insulatio - - - -030.5 ft 1st Floor 3 672 ft² 0.32 0 0.68______Floor Over Other Space 0 - - - - - - - -2nd Floor #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Composition shingles 990 ft² Medium 0.85 0 26.6______N222 ft² 0.9 NoY ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______1 Full attic Vented 885 ft² Y N300 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 55 ft² 0.11 Wood______1st Floor Blown 2 Under Attic (Vented)30 830 ft² 0.11 Wood______2nd Floor Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 13 02nd Floor 00098WFrame - Wood 0.60.23Exterior72.0 ft² ____ 2 4.1 01st Floor 08038WConcrete Block - Int Insul 0.60Exterior26.0 ft² ____ 3 13 02nd Floor 006198NFrame - Wood 0.60.23Exterior156.0 ft² ____ 4 4.1 01st Floor 08088NConcrete Block - Int Insul 0.60Exterior69.3 ft² ____ 5 13 02nd Floor 006198SFrame - Wood 0.60.23Exterior156.0 ft² ____ 6 4.1 01st Floor 086198SConcrete Block - Int Insul 0.60Exterior169.0 ft² ____ 7 13 01st Floor 080208-Frame - Wood 0.010.23Garage173.3 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Wood .25 20 ft² None______N 1st Floor 863 2 Wood .25 17.8 ft² None______-1st Floor 8682 #Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Low-E Double 0.36 0.22 15.0 ft² 1 ft 0 in 0 ft 9 in Drapes/blindsVinyl Exterior 5______Yes3 N 2 N Low-E Double 0.36 0.22 15.0 ft² 1 ft 0 in 3 ft 11 in Drapes/blindsVinyl Exterior 5______Yes3 N 3 S Low-E Double 0.36 0.22 30.0 ft² 1 ft 0 in 0 ft 9 in Drapes/blindsVinyl Exterior 5______Yes5 N 4 S Low-E Double 0.36 0.22 30.0 ft² 1 ft 0 in 11 ft 1 in Drapes/blindsVinyl Exterior 5______Yes6 N 5 S Low-E Double 0.61 0.25 40.0 ft² 1 ft 0 in 11 ft 1 in NoneMetal Exterior 5______Yes6 N #Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 226 ft² 226 ft² 23.05 ft 8.7 ft 1______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1512.6 782.98.00037Wholehouse .1887155.79Proposed ACH(50)1 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM #System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Heat Pump/HSPF:8.5 28.4 kBtu/hr ______sys#1Split1 Singl #System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 15 28.4 kBtu/hr c f m 0.75______sys#1Split1 Singl #System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 2.45 50 gal 60 gal 120 deg None______Heat Pump Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ #Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 311.4 ft Attic 77.85 ft Default Leakage 2nd Floor ( D e f a u l t ) ______1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH)AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH)AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MECHANICAL VENTILATION Supply CFM Exhaust CFM Heating System Cooling SystemHRVTypeRun TimeFan Watts 46 0 0Runtime Vent 1 - Electric Heat Pump 1 - Central Unit%0 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 1st Floor Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 2nd Floor 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT , , FL, 3/18/2021 9:48 AM3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Attached 1 3 No 1557 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Dbl, U=0.36 90.00 ft² SHGC=0.22 Dbl, U=0.61 40.00 ft² SHGC=0.25 N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. Floor Over Other Space c. other (see details) R=0.0 727.00 ft² R=0.0 672.00 ft² R=158.00 ft² 10. Wall Type and Insulation a. Frame - Wood, Exterior R=13.0 384.00 ft² b. Concrete Block - Int Insul, Exterior R=4.1 264.33 ft² c. Frame - Wood, Adjacent R=13.0 173.33 ft² 11. Ceiling Type and insulation level a. Under Attic (Vented)R=30.0 885.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 2.45 b. Conservation features None d. N/A R=f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method)Pstat Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 1.000 ft. 0.229 a. Electric Heat Pump 28.4 HSPF:8.50 a. Central Unit 28.4 SEER:15.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 311.4 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 3/18/2021 9:48 AM FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2020 report Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) . 3/18/2021 9:47:50 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: 581000 Permit #: Job Information Builder: KB Homes Community: Lot: 154 Address: City:State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub-section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): 7.000 _________ x 60 ÷ ______________ = ____________12965 CFM(50) Building Volume ACH(50) PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume:_____________________________ Retrieved from architectural plans Code software calculated Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: ______________________________________ Phone: ________________________ I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________ Date of Test: ______________________ Printed Name of Tester: _________________________________ License/Certification #: _____________________________ Issuing Authority: _________________________ 3/18/2021 9:48:36 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Name: Owner: Builder Name: Permit Office: Jurisdiction:581000 KB HomesLot154Bldg8Landings@Riverbend2201557GLN Street: City, State, Zip:, FL , Permit Number: Design Location:FL, Orlando CH E C K AIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software3/18/2021 9:48 AM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods Florida Building Code, Energy Conservation, 7th Edition (2020) ADDRESS: , FL , Permit Number: The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. MANDATORY REQUIREMENTS - See individual code sections for full details. R402.4 Air leakage (Mandatory). During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. R401.3 Energy Performance Level (EPL) display card (Mandatory). 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 R402.4.3 Fenestration air leakage. R402.4.1.1 Installation. Exception: Site-built windows, skylights and doors. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. Exception: R402.4.1.2 Testing. R402.4.1 Building thermal envelope. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer’s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE MANDATORY REQUIREMENTS - (Continued) Building framing cavities shall not be used as ducts or plenums. Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 R403.3.5 Building cavities (Mandatory). R403.4 Mechanical system piping insulation (Mandatory). R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). SECTION R403 SYSTEMS R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be “substantially leak free” in accordance with Section R403.3.3. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. 1. Exceptions: A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. 2. 1. R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. 1. 2. R403.5.1.1 Circulation systems. R403.5.1.2 Heat trace systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. MANDATORY REQUIREMENTS - (Continued) 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 ½ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and Be installed at an orientation within 45 degrees of true south. 1. 2. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. When installed to function as a whole-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. R403.6.1 Whole-house mechanical ventilation system fan efficacy. E x c e p t i o n : R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. 1. 2. 3. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY For SI: 1 cfm = 28.3 L/min.a.When tested in accordance with HVI Standard 916 HRV or ERV In-line fan Bathroom, utility room Bathroom, utility room FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY AIRFLOW RATE MAXIMUM (CFM)(CFM/WATT) a Any Any 10 90 1.2 cfm/watt 2.8 cfm/watt 1.4 cfm/watt 2.8 cfm/watt Any Any <90 Any (CFM) Range hoods Any 2.8 cfm/watt Any MANDATORY REQUIREMENTS - (Continued) R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: Where public health standards require 24-hour pump operation. R403.10.2 Time switches. Pumps that operate solar- and waste-heat-recovery pool heating systems. Where pumps are powered exclusively from on-site renewable generation.3. 2. 1. 3/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. 2. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. SECTION R404 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. ELECTRICAL POWER AND LIGHTING SYSTEMS Page 5 of 53/18/2021 9:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software All gas- and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.4 Gas- and oil-fired pool and spa heaters. Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recovered energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required. Exception: Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. R403.10.3 Covers. R403.13 Dehumidifiers (Mandatory Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: R403.13.1 Ducted dehumidifiers. If installed, a dehumidifier shall conform to the following requirements: 1.The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2.The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3.Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4.Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. 1.If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2.If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3.A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4.Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. 2021-Mar-18 09:49:16 Right-Suite® Universal 2021 21.0.02 RSU24009 Page 1 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Ri...Job:Manual S Compliance Report February 21, 2020Date:Entire House RHBy: Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com Project Information KB HomesFor: FL Cooling Equipment Design Conditions °F77.9Entering coil DB:Btuh19568Sensible gain:°F92.5Outdoor design DB: °F64.2Entering coil WB:Btuh4860Latent gain:°F76.2Outdoor design WB: Btuh24427Total gain:°F75.0Indoor design DB: cfm947Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 25HBC530A00300+FX4DNF031LModel:CarrierManufacturer: cfm947Actual airflow: % of load115Btuh22479Sensible capacity: % of load105Btuh5082Latent capacity: %82SHR:% of load113Btuh27561Total capacity: Heating Equipment Design Conditions °F67.9Entering coil DB:Btuh14850Heat loss:°F42.3Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 25HBC530A00300+FX4DNF031LModel:CarrierManufacturer: cfm947Actual airflow: °F27Capacity balance:% of load184Btuh27359Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm947Actual airflow: °F50Temp. rise:% of load156kW6.8Output capacity: Meets all requirements of ACCA Manual S. 2021-Mar-18 09:49:16 Right-Suite® Universal 2021 21.0.02 RSU24009 Page 1 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Ri...Job:Component Constructions February 21, 2020Date:Entire House RHBy: Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com Project Information KB HomesFor: FL Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Orlando/Jetport, FL, US 1828Design TD (°F)ft105Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:45.80.8Moisture difference (gr/lb)CoolingHeating Infiltration:9342Dry bulb (°F) SimplifiedMethod)M(16-Daily range (°F) AverageConstruction quality76-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls W 12C-0sw: Frm wall, stucco ext, 3/8" wood shth, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4" wood frm, 16" o.c. stud 3512.783112.4713.00.089126n 3512.783112.4713.00.089126s 2002.781782.4713.00.08972w 9022.787992.4713.00.089324all W 13A-4ocs: Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh 2625.292765.574.10.20150n 5275.295545.574.10.20199s 1385.291455.574.10.20126w 9275.299755.574.10.201175all Partitions WP 12C-0sw: Frm wall, 1/2" gyp.bd ext, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4" wood frm, 16" o.c. stud 2781.783982.5513.00.092156 Windows 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.22); 1 ft overhang (5 ft window ht, 0.71 ft sep.); 8 ft head ht 16410.91509.9700.36015n 32911.02999.9700.36030s 49310.94499.9700.36045all 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.22); 1 ft overhang (5 ft window ht, 3.95 ft sep.); 8 ft head ht 16410.91509.9700.36015n 2A-2omd: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.25); 1 ft overhang (6.7 ft window ht, 11.05 ft sep.); 8 ft head ht 68717.167916.900.61040s 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.22); 1 ft overhang (5 ft window ht, 11.05 ft sep.); 8 ft head ht 35912.02999.9700.36030s Doors 11D0: Door, wd sc type 24212.021710.800.39020n 21512.019310.800.39018n 45712.041010.800.39038all Ceilings 2021-Mar-18 09:49:16 Right-Suite® Universal 2021 21.0.02 RSU24009 Page 2 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N 16CR-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2" gypsum board int fnsh 12561.427840.8930.00.032885 Floors 20P-13c: Flr floor, frm flr, 12" thkns, carpet flr fnsh, r-13 cav ins, gar ovr 1540.982981.8813.00.068158 22A-tpl: Bg floor, light dry soil, on grade depth 0.98951 00138327.40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 1 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Ri...Job:Project Summary February 21, 2020Date:Entire House RHBy: Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com Project Information KB HomesFor: FL LS.10/12/20.RC.Notes: Design Information Orlando/Jetport, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F93Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F18Daily range M Relative humidity %50Moisture difference gr/lb46 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh9992 Structure Btuh13116 Ducts Btuh3462 Ducts Btuh5570Central vent (46 cfm) 1396 Btuh Central vent (46 cfm) Btuh882 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh14850 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh19568 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2589 Ducts Btuh844Central vent (46 cfm) Btuh1426 CoolingHeating Outside air 15571557Area (ft²)Equipment latent load Btuh4860 1331313313Volume (ft³) Air changes/hour 0.260.50 Equipment Total Load (Sen+Lat)Btuh24427 Equiv. AVF (cfm) 58111 Req. total capacity at 0.75 SHR ton2.2 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC530A00300 Cond 25HBC530A00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling Btuh21300 Heating output Btuh @ 47°F28200 Latent cooling Btuh7100 Temperature rise °F27 Total cooling Btuh28400 Actual air flow cfm947 Actual air flow cfm947 Air flow factor cfm/Btuh0.070 Air flow factor cfm/Btuh0.051 Static pressure in H2O0.40 Static pressure in H2O0.40 Space thermostat Load sensible heat ratio 0.80 Capacity balance point = 27 °F Backup:Input = 7 kW, Output = 23106 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 1...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Entire House Great Rm 2 Exposed wall 98.5 ft 19.5 ft 3 Room height 8.3 ft 8.7 heat/coolft 4 Room dimensions ft441.0x1.0 5 Room area 1600.5 ft²441.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 156 126 311 351 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 15 0 150 164 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 15 0 150 164 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 70 49 276 262 0 0 0 0 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 20 20 217 242 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 156 126 311 351 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 30 28 299 329 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 170 99 554 527 170 99 554 527 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 40 0 679 687 40 0 679 687 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 30 0 299 359 30 0 299 359 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 72 72 178 200 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 26 26 145 138 0 0 0 0 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 174 156 398 278 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 18 18 193 215 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 885 885 784 1256 0 0 0 0 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 158 158 298 154 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 727 51 1383 0 441 20 534 0 6 c) AED excursion 13 74 Envelope loss/gain 6624 5690 2066 1647 12 a) Infiltration 3368 1106 880 289 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 5400 1800 Subtotal (lines 6 to 13)9992 13116 2946 3736 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 9992 13116 2946 3736 15 Duct loads 35%42%3462 5570 15%15%442 560 Total room load 13453 18686 3388 4296 Air required (cfm)Air required (cfm)947 947 238 218 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 2...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Kitchen/Entry Pwdr 2 Exposed wall 14.5 ft 16.5 ft 3 Room height 8.7 heat/coolft 8.7 heat/coolft 4 Room dimensions ft249.5x1.0 ft36.3x1.0 5 Room area 249.5 ft²36.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 35 15 82 78 35 35 194 184 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 20 20 217 242 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 0 0 0 0 0 0 0 0 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 0 0 0 0 26 26 145 138 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 91 73 187 131 83 83 211 147 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 18 18 193 215 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 0 0 0 0 11 11 10 16 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 250 15 397 0 36 17 452 0 6 c) AED excursion -17 -4 Envelope loss/gain 1076 649 1012 482 12 a) Infiltration 180 59 316 104 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 1800 0 Subtotal (lines 6 to 13)1257 2508 1328 585 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1257 2508 1328 585 15 Duct loads 15%15%189 376 15%15%199 88 Total room load 1446 2884 1527 673 Air required (cfm)Air required (cfm)102 146 107 34 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 3...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Master Bedroom M.Wic 2 Exposed wall 13.5 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft12.5x13.5 ft7.0x6.0 5 Room area 168.8 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 108 78 192 217 48 48 118 134 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 30 28 299 329 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 0 0 0 0 0 0 0 0 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 0 0 0 0 0 0 0 0 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 169 169 150 239 42 42 37 60 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -12 -2 Envelope loss/gain 641 774 156 191 12 a) Infiltration 560 184 249 82 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 600 0 Subtotal (lines 6 to 13)1201 2018 404 273 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1201 2018 404 273 15 Duct loads 59%72%709 1459 59%72%239 198 Total room load 1910 3477 643 471 Air required (cfm)Air required (cfm)134 176 45 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 4...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name M.Bth Hall/Laundry 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x6.0 ft215.3x1.0 5 Room area 66.0 ft²215.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 0 0 0 0 0 0 0 0 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 0 0 0 0 0 0 0 0 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 66 66 59 94 215 215 191 305 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -6 Envelope loss/gain 59 93 191 299 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 600 Subtotal (lines 6 to 13)59 93 191 899 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 59 93 191 899 15 Duct loads 59%72%35 67 59%72%113 650 Total room load 93 160 303 1550 Air required (cfm)Air required (cfm)7 8 21 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 5...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Bdrm 3 Bdrm 3 Wic 2 Exposed wall 20.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft140.8x1.0 ft5.0x5.0 5 Room area 140.8 ft²25.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 92 77 190 214 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 15 0 150 164 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 0 0 0 0 0 0 0 0 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 72 72 178 200 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 0 0 0 0 0 0 0 0 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 141 141 125 200 25 25 22 35 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 132 132 249 129 20 20 38 20 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -11 0 Envelope loss/gain 891 896 60 55 12 a) Infiltration 851 279 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 300 0 Subtotal (lines 6 to 13)1741 1705 60 55 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1741 1705 60 55 15 Duct loads 59%72%1027 1233 59%72%35 39 Total room load 2769 2938 95 94 Air required (cfm)Air required (cfm)195 149 7 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 6...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Bdrm 2 Bdrm 2 Wic 2 Exposed wall 8.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft127.5x1.0 ft3.5x8.0 5 Room area 127.5 ft²28.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW W 12C-0swW 12C-0sw 0.0890.089 nn 2.472.47 2.782.78 64 49 121 136 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 15 0 150 164 0 0 0 0 .GG 2A-2ov2A-2ov 0.3600.360 nn 9.979.97 10.9010.90 0 0 0 0 0 0 0 0 .WW W 13A-4ocsW 13A-4ocs 0.2010.201 nn 5.575.57 5.295.29 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ss 2.472.47 2.782.78 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 10.9710.97 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ss 5.575.57 5.295.29 0 0 0 0 0 0 0 0 GG 2A-2omd2A-2omd 0.6100.610 ss 16.9016.90 17.1017.10 0 0 0 0 0 0 0 0 GG 2A-2ov2A-2ov 0.3600.360 ss 9.979.97 11.9511.95 0 0 0 0 0 0 0 0 WW W 12C-0swW 12C-0sw 0.0890.089 ww 2.472.47 2.782.78 0 0 0 0 0 0 0 0 WW W 13A-4ocsW 13A-4ocs 0.2010.201 ww 5.575.57 5.295.29 0 0 0 0 0 0 0 0 PP WP 12C-0swWP 12C-0sw 0.0920.092 --2.552.55 1.781.78 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.8010.80 12.0312.03 0 0 0 0 0 0 0 0 CC 16CR-30ad16CR-30ad 0.0320.032 --0.890.89 1.421.42 128 128 113 181 28 28 25 40 FF 20P-13c20P-13c 0.0680.068 --1.881.88 0.980.98 6 6 11 6 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.4027.40 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -7 0 Envelope loss/gain 395 479 25 39 12 a) Infiltration 332 109 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 300 0 Subtotal (lines 6 to 13)727 1118 25 39 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 727 1118 25 39 15 Duct loads 59%72%429 809 59%72%15 29 Total room load 1155 1927 39 68 Air required (cfm)Air required (cfm)81 98 3 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-18 09:49:16Right-Suite® Universal 2021 21.0.02 RSU24009 Page 7...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Riverb...Job:Right-J® Worksheet February 21, 2020Date:Entire House RHBy:Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com 1 Room name Bth 2 2 Exposed wall 0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft5.5x11.0 5 Room area 60.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W W 12C-0sw 0.089 n 2.47 2.78 0 0 0 0 .G 2A-2ov 0.360 n 9.97 10.90 0 0 0 0 .G 2A-2ov 0.360 n 9.97 10.90 0 0 0 0 .W W 13A-4ocs 0.201 n 5.57 5.29 0 0 0 0 11 D 11D0 0.390 n 10.80 12.03 0 0 0 0 W W 12C-0sw 0.089 s 2.47 2.78 0 0 0 0 G 2A-2ov 0.360 s 9.97 10.97 0 0 0 0 W W 13A-4ocs 0.201 s 5.57 5.29 0 0 0 0 G 2A-2omd 0.610 s 16.90 17.10 0 0 0 0 G 2A-2ov 0.360 s 9.97 11.95 0 0 0 0 W W 12C-0sw 0.089 w 2.47 2.78 0 0 0 0 W W 13A-4ocs 0.201 w 5.57 5.29 0 0 0 0 P WP 12C-0sw 0.092 -2.55 1.78 0 0 0 0 D 11D0 0.390 n 10.80 12.03 0 0 0 0 C 16CR-30ad 0.032 -0.89 1.42 61 61 54 86 F 20P-13c 0.068 -1.88 0.98 0 0 0 0 F 22A-tpl 0.989 -27.40 0.00 0 0 0 0 6 c) AED excursion -1 Envelope loss/gain 54 85 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)54 85 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 54 85 15 Duct loads 59%72%32 62 Total room load 85 147 Air required (cfm)6 7 2021-Mar-18 09:49:17 Right-Suite® Universal 2021 21.0.02 RSU24009 Page 1 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Lot154Bldg8Landings@Ri...Job:Duct System Summary February 21, 2020Date:Entire House RHBy: Del-Air Heating & Air Conditioning 531 Codisco Way, Sanford, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: www.del-air.com Project Information KB HomesFor: FL CoolingHeating External static pressure in H2O0.40in H2O0.40 Pressure losses in H2O0.06in H2O0.06 Available static pressure in H2O0.34in H2O0.34 Supply / return available pressure 0.170 / 0.170 in H2O in H2O0.170 / 0.170 Lowest friction rate in/100ft0.281in/100ft0.281 Actual air flow cfm947cfm947 Total effective length (TEL)ft121 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st285.021.4VlFx0x06.00.32098811927cBdrm 2 st285.016.6VlFx0x04.00.3353368cBdrm 2 Wic st285.026.8VlFx0x08.00.3041491952769hBdrm 3 st285.022.9VlFx0x04.00.3155795hBdrm 3 Wic 70.07.2VlFx0x04.00.44176147cBth 2 st190.020.1VlFx0x06.00.30973791129hGreat Rm st190.021.6VlFx0x06.00.30573791129hGreat Rm-A st190.015.9VlFx0x06.00.32173791129hGreat Rm-B 70.08.1VlFx0x05.00.43579211550cHall/Laundry st190.025.4VlFx0x07.00.2951461022884cKitchen/Entry 70.06.3VlFx0x05.00.44687160cM.Bth 70.015.0VlFx0x04.00.4002445643hM.Wic 70.012.5VlFx0x08.00.4121761343477cMaster Bedroom st190.030.9VlFx0x05.00.281341071527hPwdr Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 448 398 0.281 570 12.0 0x0 VinlFlx st2 Peak AVF 286 255 0.304 647 9.0 0x0 VinlFlx 2021-Mar-18 09:49:17 Right-Suite® Universal 2021 21.0.02 RSU24009 Page 2 ...7GL\Lot154Bldg8Landings@Riverbend2201557GLN.rup Calc = MJ8 House faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 9470 947 0 0 0 0 x0 0 VlFx 14"x12"x48" 10x6 1wcd 75 10x6 1wcd 75 145 10x6 1wcd 35 platform by bldr Scale :1/8"=1'0" 42"x42" A/C Slab By Builder Min. 2' from Wall 2.5 ton w/5kw 240v 1ph 18x10 Plen A/C PAD T/S 18x18 rag 5 8x4 1wcd 5 10x6 1wcd 100 14x8 1wcd 150 8x4 1wcd 5 10x6 1wcd80 10 8x4 1wcd 2514x8 1wcd 175 6" 6" 7" 5" 7" Kitchen duct to roof or wall cap f 5" bath duct to roof or wall cap AE100BF f 5" bath duct to roof or wall cap AE100BF f 4" dryer duct to roof or wall cap w/dryer vent box 9" 4" 6" 8" 4" 4" 8x4 1wcd 5" 8" 4"10x6 1wcd 75 OR FLEX TO 10x10 RAG WITH INSECTSCREEN OR WALL CAP INSULATE W/ 1.5 IN DUCT WRAP Y8150 FRESH AIR DAMPER 6" SNAPLOCK, FLEXABLE METAL PIPE, AIR VENTILATION SYSTEM HONEYWELL Y8150 FRESH OUTSIDE AIR DETAIL TO SOFFIT OR WALL CAP 12" 10x6 1wcd 5" 14x14 rag 16x16 rag 12x12 rag9" 12" 14x14 rag 14x14 rag12" Transfer ducts/grilles sized in compliance with Florida Residential Building Code - M1602.4 Balanced Return Air, exceptions 1-3. Builder must provide unrestricted 1 inch undercut on doors to habitable rooms. 6" 12x6 1wcd D e l A i r He a t i n g , A i r C o n d i t i o n i n g & R e f r i g e r a t i o n , I n c . 5 3 1 C o d i s o W a y S a n f o r d F l . 3 2 7 7 1 - 6 2 0 6 P h o n e : 4 0 7 - 8 3 1 - 2 6 6 5 F a x : 4 0 7 - 3 3 3 - 3 8 5 3 Bu i l d e r : Pl a n : Lo t : Su b d i v i s i o n Da t e : Dr a w n b y : R e v i s i o n s D a t e B y Must have a minimum clearance of 4 inches around the air handler per the State Energy code. All duct has an r=6 insulation value. Fe b r u a r y 2 1 , 2 0 2 0 RHKB H o m e s 22 0 - 1 5 5 7 15 4 B L D G 8 LA N D I N G S @ R I V E R B E N D 10 / 1 2 / 2 0 R C