1411 Locust Ave 08-2547TURQUOISE Consulting Inc. Structural Engineering & Design. CA #26031 6915 Washington Road, W. Palm Beach, FL 33405 Ph.(561)804 -9908 Fax(561)804 -9907 TO: City of Sanford / Building Division October 30, 2008 FROM: Riza N. ALTAN, P.E. SUBJECT: In- Progress & Final / Asphalt Shingles Installation ADDRESS: J. HENKINS Residence / 1411 S. Locust Avenue, Sanford, FL CONTRACTOR: Roofing USA, Inc. PERMIT: #08 -2457 Dear Sir; The asphalt shingles roof covering for the subject residence has been field- inspected by my self, after its completion. The purpose of this inspection was to determine the level of code conformance for roof coverings. The one - story-high roof has 3/12 slope. A careful inspection has revealed the following: A) The existing 1x6 wood deck is adequately re- nailed using additional 8d ring - shanked nails spaced at 4" o.c. B) The roof deck is covered with double layers of ASTM D 226 Type2 (30 -lbs) felt, properly tin - tagged using 11 ga., 1 11" long ring - shanked roofing nails spaced 6" and 12" o.c., on the laps and in field, respectively. C) All 26 ga. galvanized flashing and drip edges are adequately overlapped and installed using 12 ga. 1 -1/4" MDA approved roofing nails spaced at 4" o.c. D) Nail penetrations of drip edges are provided with 8" wide starter row membrane. Therefore, this letter is to certify that deck re- nailing, installation of roof metals, exposure and course layout of Owens Corning asphalt shingles are properly completed, using (6)12 ga. 1'/" long ring - shanked roofing nails per accordance with requirements of 2007 Revisions to 2004 Florida Building Code. Ingle, in If you have any questions regarding this matter or I may be of further assistance, please do not hesitate to call me. . Sincerely, `�`0%%%111fill,/ N ._� o�% tip, . ACT i � \•� °•.......m '9ti poi ,� I ®® EN °. Riza AL AN, P.E. #38521 0 o No. 38521 * _ Consul i Engineer ° STATE OF r e � �'�oe 8/0 `,` A ;1ti1 BP502IO2 CITY OF SANFORD Inspection In 10/31/08 Inquiry - Results Comments 13:57:00 Parcel Number 31.19.31.505- 0000 -0640 Property address 1411 LOCUST AVE Appl, structure nbr . . . . Permit type, 08 00002457 000 000 seq nbr ROOF 00 ROOFING /REROOFING PERMIT Inspection type, seq nbr 131,15 0001 REROOF DRY IN Inspection status, date INSPECTION COMPLETED 9/05/08 Inspection Results Comments 09/05/2008 01:09 PM 148 PDA Rear roof approved by Rodger Addison. Contractor covered front roof prior to inspection. He was instructed not to cover the front roof. A Florida design professionals letter will be required for this area of the roof for dry -in. Press Enter to continue. Bottom F3 =Exit F12= Cancel