408 Treasure Ln 16-2929 (a)THORNBROOKE 50's COMMUNITY SPECIFIC STANDARD SPECIFICATIONS REDRAW NOTES MONOLITHIC FOOTINGS, ALUMINUM OVER 2x6 5UD-F46CIA, SHINGLE ROOF, ELECTRIC HEAT, 50 GAL. ELECTRIC WATER HEATER,150 AMP. 5ERVICE, PAVER DRIVEWAY, PAVER LEAD WALKS, PAVER ENTRY, ACRYLIC LANAI LOT 25 - THORNBROOKE 50's STANTON - 2055 ELEVELEV.ifME -MEDITERRANEAN" GARAGE RIGHT TAYLOR MORRISON 10-06-16 CREATED LOT SPECIFIC; PLAN FOR LOT 25 IN THORNDROOKE 50'5, ELEVATION "ME - MEDITERRANEAN", GARAGE LEFT U / f`'1_41\1 OPTION5 (INCLUDING: (5) CEILING F -AN PRE -WIRE, TRAY CEILINCi AT M45TE ,5'JITE, i NICHE5 AT FOYER, 12 FT. POCKE J' 5I IDI �Q) AT FAMILY ROOM, FRONT L)OOR GL4 ,55 iN5 RT, OPTIONAL M45TER 54TH, 5 REC,F�'5L�AN LIGHTS, UNDER CAE3INE f LIGHTIN(k1NI�> .� VENT HOOD TO OUT5IDE, PLAN REVISIONS 10 T', 16 COMPLETED REV15ION TO INCLUDE: MIRRORED PLAN TO CREATE GARAGE RIGHT HAND PLAN. RECORD COPY MIME ED FOR CODE COMPLIANCE; FLANS EXAMINER _1r - DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE COMPACTION TEST REQUIRED Results to be Verified at tab lnspa6tion G DRAWING INDEX COV -GENERAL NOTES, INDEX, SPECIFICATIONS 1 -SLAB INTERFACE PLAN 2A -FLOOR PLAN NOTES 2B -FLOOR PLAN DIMENSIONS 3A1 -FRONT ELEVATION 3A2 -SIDE ELEVATIONS, ROOF PLAN, BUILD. SECTION 3A3 -FLASHING DETAILS 3A4 -FLASHING DETAILS 4 -ELECTRICAL PLAN GENERAL CONSTRUCTION NOTES CHAPTERS AND SECTIONS REFER TO F.B.C.R. - 5TH EDITION (2014). NOTE: ANY DIMENSIONS AND/OR CALLOUT5 WITHIN THI5 SET OF DRAWINGS REFERENCING LUMBER SIXES OR WALL THICKNESS ARE TO BE CONSIDERED "NOMINAL DIMENSIONS" OCCUPANCY AND CONSTRUCTION TYPE: THI5 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V -B CLASSIFICATION, EXTERIOR WALL ENVELOPE: BUILDER 15 RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF SECTION 101.2.4 OF THE F.B.C.-BUILDING BY PROVIDING ALL DETAILS L15TED UNDER THI5 SECTION, INCLUDING BUT NOT LIMITED TO, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL SUPPORTING DOCUMENTATION TO ENSURE THE WEATHER RE516TANCE OF THE EXTERIOR WALL ENVELOPE 15 MAINTAINED. CEILING CONSTRUCTION: I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN 5/8 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION 15 A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT IN ACCORDANCE WITH • F.B.C.R. - 5TH EDITION (2014) 8102.3.5. • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 EXTERIOR FIN15HE5: ISSUED 10-06-16 INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) 8103.6.1 AND A5TM G 1063, ALL LATH AND LATH ATTACHMENTS SHALL BE REVISED 10-21-16 OF CORRO51ON-RE515TANT MATERIAL. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 11/2 INCH 11 GAUGE NAILS HAVING A 1/16 INCH HEAD, OR 1/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED, THICKNESS OF TEXTURED FIN15H OVER FRAME APPLICATION TO BE PER RB.G.R - 5TH EDITION (2014) 8103.6.2 AND A5TM C 926. PER F.B.C.R. 5TH EDITION (2014) 8103.6.2.1 WEEP 5CREED5 SHALL BE A MINIMUM NO. 26 GALVANIZED SHEET GAUGE CORRO51ON-RE515TANT WEEP SCREED OR PLASTIC WEEP 5CREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH A5TM C 926. THE WEEP 5CREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS, THE WEATHER RE515TANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP 5CREED. PER F.B.C.R. 5TH EDITION (2014) R103b.3 WATER RESISTIVE BARRIERS INSTALLED OVER WOOD BASED SHEATHING SHALL INCLUDE A WATER RE515TIVE VAPOR PERMEABLE BARRIER EQUIVALENT TO 2 LAYERS OF GRADE D PAPER, STUCCO APPLICATION AND CURING PER F.B.C.R. 5TH EDITION (2014) 8103.65 OR IN ACCORDANCE WITH A5TM C 926, STUCCO CONTROL JOINTS: mmmm STUCCO CONTROL JOINTS TO BE INSTALLED PER A5TM C 1063-06(1.11.4.1 THRU 1.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 5F. AND DELINEATE AREAS NOT MORE THAT 100 5F. FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT, IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO I. A CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE EXPANSION JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS, EGRE55: 1, EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE 15 NO ACCESS TO EXTERIOR THROUGH A DOOR, THE WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. FL45HING: 1. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. 2. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORRO5ION-RE516TANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER 8103.8, WINDOW IN5TALLATION: I. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS, WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW, • x m LU 0) Z-1 DAVIS BEWS DESIGN GROVP C UTo too 150 STATE STR EEi EAST OLDSMAR, FLORIDA 34677 813. 925. 1300 TEL 813.925.1800 FAX W W W-DAVISBEWS.COM TAPA • ENVER- ML7 FST. 1994 (;--� j 0 J I, V) I I N ' FLOOD ZONE REQUIREMENTS: VI � E; ag 00 -S •2 N ih N d , 6 Ln � '= J M C) L ���• ASPHALT 5HINGLE5 IIF APPLICABLE) : 00 ro= '0 JRo C I. WIND RE515TANCE OF ASPHALT SHINGLES, - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R90516 AND 8905.2.6.1. ?, U- coUl _omGo 3�E V'L 06 0�1�11101 _' L N HORIZONTAL (2:12) AND LE55 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH A51M D 226, TYPE 1 OR TYPE 11, A5TM D 4869, TYPE II OR �+ zV24 TYPE IV OR ASTM p 615115 REQUIRED IN ACCORDANCE WITH SECTION 8905.2.1, FOR ROOF SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12) AND GREATER, ONE LAYER OF HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN 5/8 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION 15 A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT IN ACCORDANCE WITH • F.B.C.R. - 5TH EDITION (2014) 8102.3.5. • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 EXTERIOR FIN15HE5: ISSUED 10-06-16 INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) 8103.6.1 AND A5TM G 1063, ALL LATH AND LATH ATTACHMENTS SHALL BE REVISED 10-21-16 OF CORRO51ON-RE515TANT MATERIAL. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 11/2 INCH 11 GAUGE NAILS HAVING A 1/16 INCH HEAD, OR 1/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED, THICKNESS OF TEXTURED FIN15H OVER FRAME APPLICATION TO BE PER RB.G.R - 5TH EDITION (2014) 8103.6.2 AND A5TM C 926. PER F.B.C.R. 5TH EDITION (2014) 8103.6.2.1 WEEP 5CREED5 SHALL BE A MINIMUM NO. 26 GALVANIZED SHEET GAUGE CORRO51ON-RE515TANT WEEP SCREED OR PLASTIC WEEP 5CREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH A5TM C 926. THE WEEP 5CREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS, THE WEATHER RE515TANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP 5CREED. PER F.B.C.R. 5TH EDITION (2014) R103b.3 WATER RESISTIVE BARRIERS INSTALLED OVER WOOD BASED SHEATHING SHALL INCLUDE A WATER RE515TIVE VAPOR PERMEABLE BARRIER EQUIVALENT TO 2 LAYERS OF GRADE D PAPER, STUCCO APPLICATION AND CURING PER F.B.C.R. 5TH EDITION (2014) 8103.65 OR IN ACCORDANCE WITH A5TM C 926, STUCCO CONTROL JOINTS: mmmm STUCCO CONTROL JOINTS TO BE INSTALLED PER A5TM C 1063-06(1.11.4.1 THRU 1.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 5F. AND DELINEATE AREAS NOT MORE THAT 100 5F. FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT, IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO I. A CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE EXPANSION JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS, EGRE55: 1, EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE 15 NO ACCESS TO EXTERIOR THROUGH A DOOR, THE WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. FL45HING: 1. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. 2. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORRO5ION-RE516TANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER 8103.8, WINDOW IN5TALLATION: I. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS, WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW, DWELLING / GARAGE OPENINGS: LU 0) Z-1 DAVIS BEWS DESIGN GROVP 150 STATE STR EEi EAST OLDSMAR, FLORIDA 34677 813. 925. 1300 TEL 813.925.1800 FAX W W W-DAVISBEWS.COM TAPA • ENVER- ML7 FST. 1994 (;--� DWELLING / GARAGE OPENINGS: LU THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 13/8" IN THICKNESS, SOLID CORE (5.C.) OR HONEYCOMB CORE STEEL DOORS a: M NOT LE55 THAN 13/6' THICK, OR 20 MINUTE FIRE RATED DOORS EQUIPPED WITH A SELF-CLOSING DEVICE. V) I I cn FLOOD ZONE REQUIREMENTS: mm E; ag 00 -S 6 PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. C) ASPHALT 5HINGLE5 IIF APPLICABLE) : C I. WIND RE515TANCE OF ASPHALT SHINGLES, - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R90516 AND 8905.2.6.1. ?, U- coUl 2. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERT!GAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS 0�1�11101 ������✓ HORIZONTAL (2:12) AND LE55 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH A51M D 226, TYPE 1 OR TYPE 11, A5TM D 4869, TYPE II OR w�e�� W TYPE IV OR ASTM p 615115 REQUIRED IN ACCORDANCE WITH SECTION 8905.2.1, FOR ROOF SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12) AND GREATER, ONE LAYER OF ��•••, ;e4 UNDERLAYMENT COMPLYING WITH A5TM D 226, TYPE 11, A5TM D 4869, TYPE IV OR ASTM D 615115 REQUIRED IN ACCORDANCE WITH SECTION 8905.2.1.o `��� �••�4 • °• i " co �fi m CLAY AND CONCRETE TILE (IF APPLICABLE) : y° * THE INSTALLATION OF CLAY AND CONCRETE TILE PER F.B.C,R - 5TH EDITION (2014) 8905.3 SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR ;U ¢ d RECOMMENDATIONS OF FR5A/TRI FLORIDA HIGH WIND CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, FIFTH EDITION WHERE THE VASD 15 DETERMINED IN ACCORDANCE WITH SECTION 8301.213 •°•.• OR THE RECOMMENDATIONS OF RA5118,119 OR 120, REQUIRED UNDERLAYMENT PER F.B.G.R. - 5TH EDITION (2014) 8905.3.3 SHALL CONFORM WITH A5TM D 226, TYPE 11; A5TM D 2626, TYPE II; OR ASTM 1910 OR ASTM AND INSTALLED IN WITH FR5A/TRI FLORIDA HIGH WIND CONCRETE AND TILE°�� �� ••°•••°•' ;fit•°C� D D 6380, CLA55 M MINERAL SURFACED ROLL ROOFING SHALL BE ACCORDANCE CLAY ROOF IN57ALLATION MANUAL, FIFTH EDITION WHERE THE vase 15 DETERMINED IN ACCORDANCE WITH SECTION 8301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118,119 OR 120. CHIMNEY HEIGHT REQUIREMENT5 (IF APPLICABLE) I. WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND 34" PAST THE HIGHER POINT WHERE IT EXTENDS THROUGH THE ROOF AND MUST BE T-0" HIGHER THAN THE ROOF OR RIDGE THAT IS 104" AWAY OR CLOSER,0 TUB AND SHOWER AREAS: I. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM C1268, CI325, OR 01118 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS. TERMITE PROTECTION: 1. PENETRATION, PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE CONTAINING MATERIALS, IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL THICKNE55 OF 0210 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. No TERMITICIDE5 SHALL BE APPLIED INSIDE THE SLEEVE. 0 2, PROTECTION AGAINST DECAY AND TERMITES. - CONDENSATE LINES, IRRIGATION / SPRINKLER SYSTEM RISERS FOR SPRAY HEADS, AND ROOF DOWN5POUT5 SHALL DISCHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHES (152 mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. MECHANICAL AND HVAC: I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THI5 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. 2. MECHANICAL APPLIANCES SHALL BE ACCE851BLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER ' PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30 INCHES (162 mm) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL 51DE TO SERVICE AN APPLIANCE. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. % GAUGE (04 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE, Ln FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RA18ED AT LEAST 3 INCHES (16 mm) ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE FACTURER'6 INSTALLATION INSTRUCTIONS, NMANU4. 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE To ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS of SECTIONS M1411.3, EXHAUST FANS AND VENTING: F� >= 1, OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE D15CHARGED TO THE OUTDOORS, AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. 0 2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT D15CHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER AREAS INSIDE THE BUILDING. 3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 35 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION, THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 25 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (Ib RAP) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE 5005TER FAN MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND NOT READILY ACCE5815LE FROM THE ROOM IN WHICH THE DRYER 115 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE � • THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "TH15 DRYER EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." 4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH AMGA STANDARD 550 IN FBG, ATTENTION GENERAL CONTRACTOR / BUILDER: 155UANCE OF PLANS FROM THI5 DRAFTER'S OFFICE SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER'5 OFFICE FOR CORRECTION BEFORE COMMENCEMENT of ANY CONSTRUCTION CORRECTION / REVISIONS ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE DRAFTER'5 OFFICE, THE DRAFTER SHALL NOT BE HELD RESPONSIBLE. REV. 09-29-1016 • SHEET �� 0 11 40'-0" 22'-0" 1'4" .. 20'-8" 3'4"64" A/C PAD (VERIFY LOCATION) t N$. 4'-8" PAVER DRIVE / LEADWALK 8" 14'-0" 5'-4" 2'-4" 16' 0" 2'-4" 20'-8" SLAB INTERFACE PLAN GARAGE RIGHT x W - `A G.C. VERIFY ACRYLIC ON LANAI DAVIS BEWS 4" P.V.G. / I' 4" J �T 150 STATE STREET EAST OLDWAR, FLORIDA 34677 813.925.1300 TEL all 811 u W W W.DAVISBEWS.COM 00 2N�M oa, Q � .,J M % / Lo�. • 00 2 ELEVATION L o� C 0 3/4" P.V.G. CONDENSATION LL=ro' 3�E t 0 ;: �) O V-411 a� / DRAIN Z��°v � BY PLUMBER 2 -6 41-411 121.2 11 31.011 RECE55 FOR POCKET SLIDER N 32'-10" 7'-2" ELEVATION AT 04" (ASSUMED) I I x I I A.W. I N _ II V \�L___j �I II T-4" 414" 16' 9" 3' 10" 2'-3" 5' 2" 10" 3'-8" 8, N OLELEVATION W 0'-4" p.W. \ o ( LAY.) ( LAY. TUB/ 6�01JER PROVIDE WATER LINE FOR ICE MAKER i�l — } all ��III III II III I I� � JUI v 20'-4" I� e T AA 3 N 20'-5" III � L �J 50 GAL, W.N. ELEVATION \ O 0'-4" z J U cl (Lif o� "v PAVERS ELEVATION u - 13' 4" 61-011 8" IV -411 8" 8 e N$. Q ELEVATION (-) 0'-6" m rn 0 N 4'-8" PAVER DRIVE / LEADWALK 8" 14'-0" 5'-4" 2'-4" 16' 0" 2'-4" 20'-8" SLAB INTERFACE PLAN GARAGE RIGHT JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 x W - DAVIS BEWS C U �0 DESIGN GPOVP J �T 150 STATE STREET EAST OLDWAR, FLORIDA 34677 813.925.1300 TEL 813. 925.1800 FAX W W W.DAVISBEWS.COM 00 2N�M N m i Q � .,J M Lo�. • 00 2 L o� C 0 LL=ro' 3�E t 0 ;: �) � ttf ti Z��°v JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 W a 0) m N 00 V) 00 � Q z F--- W 9 C) cz� 9 L Lo m rerrr�el� ®�> Lu co Poo i '°'> Q +° d yw` ✓� 4 .00 ` ° �� ee` a ci UO o W Z r*4 J F� >= 0 2055 • TI TLE • SLAB INTERFACE PLAN • SHEET • DAVIS BEWS DESIGN GPOVP 150 STATE STREET EAST OLDWAR, FLORIDA 34677 813.925.1300 TEL 813. 925.1800 FAX W W W.DAVISBEWS.COM TAMPA • L7ENVEP_ EST. 1994 W a 0) m N 00 V) 00 � Q z F--- W 9 C) cz� 9 L Lo m rerrr�el� ®�> Lu co Poo i '°'> Q +° d yw` ✓� 4 .00 ` ° �� ee` a ci UO o W Z r*4 J F� >= 0 2055 • TI TLE • SLAB INTERFACE PLAN • SHEET • ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL COMPLY WITH 8310 PER F,B.G.R. - 5TH EDITION (2014). * * * * * * NICHE (-) 41' NICHE ( ) 4" M NICHE DETAIL ASCALE: 1/4" = 1'-0" REFER TO SHEET 2B FOR FLOOR PLAN W/ DIMENSIONS o� /1 TION, 9'-4" AFF. BOTTOM OF LINTEL AT V-0" AFF I I -------------- G.G. VERIFY ACRYLIC LANAI ON LANAI 22'-0"x8'-0" 9'-4" PLT, HT. A/C PAD T.O.M. (VERIFY g4' 3 - 25 SH. LOCATION) HD, AT V-0" * EGRESS t H.B. 9'-4" FLAT CLG. � 10'-0" FLAT CLG. II MASTER SUITE 16'-8"x12'-10" 10'-0" TRAY CLG. FLUSH FRAME 12-0X8-0 TEMP. PKT. SLIDER v TO PURRING I � � o - � � m ARCHFROM FAMILY ROOM i I 2 6x6 s 19'-0"x13'-4" VAULTED CLG. j. 2.96:12 24" CLG, 2.96:12 SLOPE CLG, n rrL— VAULTth N — 2 - R/S — KNEE I W BATH L I W/ O.S.B. CPT. VINYL M. a 9'-4" FLAT CLG. CLG. 42" H. \ COUNTERTOP I ��+ TEMP. GL, ILE 01 } 53 2 ENCL. SHOUTER 01 0 \ I ATTIC D,W. \ 0 LAV. LAV. HEAD W 0 disc / FURR OUT WALL FOR TUB/ 5 -0 TUB I TEMP. GL. ENCL. ON VENT HOOD o I KITCHEN 1 SHOUTER I 42" H. LOW WALL TO EXTERIOR I VAULTED CLG. I coN X r — -in s BATH 2 III cLJ ► BEDROOM 2 o `9I 11'-0"x10'-2" CL `� II I n I - �- - - I 9'-4" FLAT CLG. L — JIJ W N W� 0 > W z `v 1b e° 12'.0" 9' 411 2,96:12 VI��CPT. 1 -h i- .6 aBRKFST. CLG. CLG. �= VAULT 10'-10"x8'-8" 2.96:12 I I 12'-0" CLG. I I AA VAULTED CLG. SLP + I I I �R��� 9'-0' FROM �� I 1� � ' 2-6x6.8 3 ARCH FROM V411 TO 9'-0" I I 1 I 1.6x6-8 ARCH FROM �) BFD a Lu 8' 6" TO 9'-0" 5 5N: BED ROOM 3 a�� - o11'-0"x10'-0" ,rQj ARCH FROM - - - -DRYER I ( 1 `� 9'-4" FLAT CLG. I= tV 64' TO 9'-0" VENT L= I o J UTI L. col g.4I �Q x I w 1 CLG. HANSEN I I I o I Box I J I 50 GAL. DINING W.H. 12'-0"x11'-6" INSULATE 9'-4" FLAT CLG. 9'-4" 12'-01 WALLS CLG. CLGcs. A o z oil / Lu !� NOTE: ALL INTERIOR X111 I ANGLED WALLS +s ARE AT 45° (U.N.O.) — — o .O.M. 22 ATTIccE A SS DEN 2055 TYPICAL MASONRY �d 9'-4" FLAT CLG. WINDOW SCHEDULE L=ANAI 11(c WINDOW WIDTHS ENTRY TO FURRING S.F. 2011 2111 3 11 J 531 T.O.M. ARCHED HDR WINDOW CALL -OUTS A.F.F.. LINE OF GARAGE DOOR IN OPEN P051TION O W 1,D0 :9 ( o '. 0 .�o co C7 26" ( 12 5H 1/2 32 5H 22 5H 32 5H w ) L4;J o��n ZG�° i M = 39" 0 13 5H 1/2 33 5H 23 5H 33 5H p51" u o 0 14 5H 1/2 34 5H 24 5H 34 5H PAVER DRIVE / LEADWALK REFER TO SHEET 25 FOR FLOOR PLAN z 63" 0 15 5H 1/2 35 SH 25 5H 35 5H i --i Z_ 72" 3: 16 5H 1/2 36 5H 26 5H 36 5H C.C. VERIFY h145ONRY OPENING5 FOR ALL WINDOW5, w JNDOI 5IZE5 AND INSTALLATION MAY VARY PER ~O MANUFACTURER AND 5PECIFICATION5. z REFER TO FLOOR PLAN5 FOR STYLE OF WINDOW U5ED (51NGLE HUNCa=5H, CA5EMENT- C5MT, OR FIXED GLA55- F.C.) NICHE (-) 41' NICHE ( ) 4" M NICHE DETAIL ASCALE: 1/4" = 1'-0" REFER TO SHEET 2B FOR FLOOR PLAN W/ DIMENSIONS o� /1 TION, 9'-4" AFF. BOTTOM OF LINTEL AT V-0" AFF I I -------------- G.G. VERIFY ACRYLIC LANAI ON LANAI 22'-0"x8'-0" 9'-4" PLT, HT. A/C PAD T.O.M. (VERIFY g4' 3 - 25 SH. LOCATION) HD, AT V-0" * EGRESS t H.B. 9'-4" FLAT CLG. � 10'-0" FLAT CLG. II MASTER SUITE 16'-8"x12'-10" 10'-0" TRAY CLG. FLUSH FRAME 12-0X8-0 TEMP. PKT. SLIDER v TO PURRING I � � o - � � m ARCHFROM FAMILY ROOM i I 2 6x6 s 19'-0"x13'-4" VAULTED CLG. j. 2.96:12 24" CLG, 2.96:12 SLOPE CLG, n rrL— VAULTth N — 2 - R/S — KNEE I W BATH L I W/ O.S.B. CPT. VINYL M. a 9'-4" FLAT CLG. CLG. 42" H. \ COUNTERTOP I ��+ TEMP. GL, ILE 01 } 53 2 ENCL. SHOUTER 01 0 \ I ATTIC D,W. \ 0 LAV. LAV. HEAD W 0 disc / FURR OUT WALL FOR TUB/ 5 -0 TUB I TEMP. GL. ENCL. ON VENT HOOD o I KITCHEN 1 SHOUTER I 42" H. LOW WALL TO EXTERIOR I VAULTED CLG. I coN X r — -in s BATH 2 III cLJ ► BEDROOM 2 o `9I 11'-0"x10'-2" CL `� II I n I - �- - - I 9'-4" FLAT CLG. L — JIJ W N W� 0 > W z `v 1b e° 12'.0" 9' 411 2,96:12 VI��CPT. 1 -h i- .6 aBRKFST. CLG. CLG. �= VAULT 10'-10"x8'-8" 2.96:12 I I 12'-0" CLG. I I AA VAULTED CLG. SLP + I I I �R��� 9'-0' FROM �� I 1� � ' 2-6x6.8 3 ARCH FROM V411 TO 9'-0" I I 1 I 1.6x6-8 ARCH FROM �) BFD a Lu 8' 6" TO 9'-0" 5 5N: BED ROOM 3 a�� - o11'-0"x10'-0" ,rQj ARCH FROM - - - -DRYER I ( 1 `� 9'-4" FLAT CLG. I= tV 64' TO 9'-0" VENT L= I o J UTI L. col g.4I �Q x I w 1 CLG. HANSEN I I I o I Box I J I 50 GAL. DINING W.H. 12'-0"x11'-6" INSULATE 9'-4" FLAT CLG. 9'-4" 12'-01 WALLS CLG. CLGcs. A o z oil / Lu !� NOTE: ALL INTERIOR X111 I ANGLED WALLS +s ARE AT 45° (U.N.O.) — — o .O.M. 22 ATTIccE A SS DEN 2055 12'-0"x11'-6" �d 9'-4" FLAT CLG. c L=ANAI 11(c FLUSH FRAME ENTRY TO FURRING S.F. 2 - 1/2 35 SH. HD. AT 6'-8" LIVING 2055 S.F. GrARAGE 460 5.1=. L=ANAI 11(c 5.1=, ENTRY 4(o S.F. TOTAL 5Q, FT. 2-131 5.1=. HATCHING LEGEND INSULATE WALL c T.O.M. GARAGE o 150 STATE STREET EAST OUD M IZ, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.17AVISBEWS.COM TAMPA • DENVER OJ 19'-4"x22'-0" 12' 0" CLG, PAVERS AFF. T T.O.M. ARCHED HDR ELEVATION) A.A.F.F.(SEE A.F.F.. c x ca GARAGE o 150 STATE STREET EAST OUD M IZ, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.17AVISBEWS.COM TAMPA • DENVER OJ 19'-4"x22'-0" w PAVERS 8'-0" PLT. HT. 0 •2N�C9 LINE OF GARAGE DOOR IN OPEN P051TION O W 1,D0 :9 ( o '. 0 .�o co eo I ( I 1 Q ) L4;J o��n ZG�° i M 0- N.B. o 0 116-0x1-0 D.N. GARAGE DOOR PAVER DRIVE / LEADWALK REFER TO SHEET 25 FOR FLOOR PLAN W/ DIMENSIONS FLOOR PLAN NOTES SCALE: 1/4" = 14' GARAGE RIG H1 JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 x ca DAVIS BEWS DESIGN GROVP C 0TO 150 STATE STREET EAST OUD M IZ, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.17AVISBEWS.COM TAMPA • DENVER OJ •2N�C9 ` ` aCoLM O W 1,D0 :9 '. 0 .�o co > hmLLt c, cq L 0-0 ._ c ) L4;J o��n ZG�° JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 w d 0) M C= K 00 C= !K00 N ~� D ® Z O a- LLI ti C-) C C--) Lr)LN u `®,111111 AI`11/ m 2 s �. z V) 0 r9000, 0 Z W z L.Loo� Lr) N 0 2055 • TITLE • FLOOR PLAN NOTES DETAILS 14 • SHEET r... • DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OUD M IZ, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.17AVISBEWS.COM TAMPA • DENVER EST. 1994 w d 0) M C= K 00 C= !K00 N ~� D ® Z O a- LLI ti C-) C C--) Lr)LN u `®,111111 AI`11/ m 2 s �. z V) 0 r9000, 0 Z W z L.Loo� Lr) N 0 2055 • TITLE • FLOOR PLAN NOTES DETAILS 14 • SHEET r... • FLOOR PLAN DIMENSIONS GARAGE RIGHT K w w REFER TO 6HEET C Utoo to 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813. 925. 1300 TEL 813. 925.1800 FAX W W WnAVISBEWS.COM TAMPA • DENVER J N 0, 0 2A FOR FLOOR PLAN N' do r I'-411 20'-a" 91-0" 9'-0" 2 N of W1 NOTES L.. JM V Lim ��LL ti � J 0T0 O d 0 m Cp = co O `) 0 o` �+ zr2,1 LANAI---—� 1 MASTER SUITE �� I_ II I_ II 11 2 -6 4 4 12 2 M.O. 3.0I 2 -0 (TYP.) n, 1 I ( r FAMILY ROOM 0 M e 1'•0" 41-0" 31-0" ji, 2' II" 3' 2" 4'.311 3'-8" (o'-2 61 al 7' 8" I' O" �^ 41-611 ° I L-- J o' -d \1 1 0, 111vi o -'7 KITCHEN co 8" I I III 1'-211 1 1 III BATH I BEDROOM 2 L JLJ O I a 2$ a BRKFST. 1 LlM 111411 I ' 0" I I' 6" 12'-0" d, 13 _ - BEDROOM 3 0 --I -1 3' L. 510 414 6 - 4 21"a4.1 III -a" cl� TIL, — I_—J o DINING 9' 6" 91-10" II 20'-O" DEN GARAGE � LL7 C'v N II -4" M.O. 1'-411 3'-4" ENTRY -- -------------------- ----------------131-411 131-411 / 1_011 n, �o 5' 4" al 51-411 REFER TO SHEET 2A FOR FLOOR PLAN 11'-4" T-811 41-81' 8" W1 NOTES 141-011 51-411 21-411 16'-0" M.O. 2'-411 19' 411 20'-8" 401.0" FLOOR PLAN DIMENSIONS GARAGE RIGHT J03NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REWSED 10-21-16 K w w DAVIS BEWS DESIGN GROVP C Utoo to 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813. 925. 1300 TEL 813. 925.1800 FAX W W WnAVISBEWS.COM TAMPA • DENVER J N 0, 0 N' do r 2 N of L.. JM V Lim ��LL ti � J 0T0 O 0 m Cp E �Lro;; N O `) 0 o` �+ zr2,1 J03NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REWSED 10-21-16 V / W � � M eca tl1 3 00 CD az Ln w ®`0111!! 111///r -J 1' C) —I u_ ♦ • ee®•e �'�y .. ayd u- 6, 0 3. m Z f�� ®••O••see•e oee� �`♦ /11111111111' W z LCL Lr) >mN 0 -< Fmm� 2055 • TI TLE • FLOOR PLAN DIMENSIONS • SHEET • DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813. 925. 1300 TEL 813. 925.1800 FAX W W WnAVISBEWS.COM TAMPA • DENVER EST. 1994 V / W � � M eca tl1 3 00 CD az Ln w ®`0111!! 111///r -J 1' C) —I u_ ♦ • ee®•e �'�y .. ayd u- 6, 0 3. m Z f�� ®••O••see•e oee� �`♦ /11111111111' W z LCL Lr) >mN 0 -< Fmm� 2055 • TI TLE • FLOOR PLAN DIMENSIONS • SHEET • 11/2" THICK SAND FIN15H KEYSTONE (IF APPLICABLE) RA15ED SAND FIN15H TEXTURED BANDING z Lid o a X � � o x z NOTE: TH15 DETAIL SHOWS THE TYPICAL THICKNE55 OF ALL RA15ED TEXTURED FINISH BANDING AND SAND FINI5HED KEY5TONE5 (WHERE APPLICABLE) IF THICKNE55 15 TO BE DIFFERENT IT WILL BE CALLED OUT AT SPECIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMEINT5 TO BE PER F.B,C.R. - 5TH 3/4" EDITION (2014) R103.6.I AND 45TM C 1063, THICK THICKNE55 OF TEXTURED FINISH OVER FRAME APPLICATION TO BE PER RB.C.R. - 5TH EDITION (2014) R103.(o2 AND A5TM C 926. TYP. CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND / OR SAND FINISH KEYSTONE 5CALE: 3" - 1' 0" CLEAR OPENING NEIGHT3 IN DWELLING UNITS, WHERE THE OPENING OF AN OPER4 5I.E WINDOW 15 LOCATED MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR 5URFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDO11 SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FIN151HED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE 5ECTION5 OF WINDOW5 SHALL NOT PERMIT OPENING5 TNAT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE WHFRI SUCH OPENINGS ARE LOCATED WITHIN 24 INCHE5 OF T'HF FINISHED FLOOR PER F.B.C.R. - 5TH EDI710N (2014) 8312.2 WINDOW FALL PREVENTION DEVICES ANID WINDOW GUARIrS; WHERE PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF ASTM F 2090 PER F.B.C.R. - 57H EDITION (2014) R312,2 TEXTURED -- FIN15H 6� S" SEGMENTED - COPED BANDING (TYP.) .I FIN15H FLOOR LINE GRADE LINE (A55UMED) 1 N 1„ 1/2.. L. - 3 11/2' 811 i u I 8" SEGMENTED DECORATIVE CROWN 3 COPED BANDING DETAIL MOLDING DETAIL ENTRY F.G. DETAIL 5CALE: 1/2" = I' -O" 5CALE: 1/2" - I' -O" 50ALE: 1/2" = I' -O" SHINGLE 12 SHINGLE ROOF a 6 ROOF � 1'-0" CROWN F ` MOULDING (5EE DETAIL) 12 5TU000 6 � i T.O.M. BEYOND FIN15H l SNINGLE 6" 5EGMENTED COPED BANDING ROOF/` 7 (TYP.) N M ALIGN TOP OF BANDING W. BOTT OF WINDOW � o -r• IFY .-.(TY . - ■l�l� FRONT ELEVATION 5CALE: 1/4" - I' -O" REFER TO COVER SHEET GENERAL NOTES FOR ROOFING UNDERLAYMENT REQUIREMENTS FOR ROOF PITCHES LE56 THAN 4:12 T.O.M. BEYOND T.O.M, - —8" 5EGMENTED COPED BANDING (TYP.) b —TEXTURED FIN15H FIN15H FLOOR L ELEVATION "ME - MEDITERRANEAN" GARAGE RIGHT JOB NUMBER 26002.2J5 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 x ro V.. 150 STATE STREET FAST OLDSMW FLORIDA 39677 813. 925.1300 TEL 813 .925.1800 FAX W W W.DAVISBEWS-COM CU 4100 410 0 JN N' n 'A 0 0IN O N am c ) L PJM L L LL 00 ro= n J 11010111111 00 o E _o �=;rn r:; 0. Z0 20 JOB NUMBER 26002.2J5 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 W d M 00 co o 000 ai ` V � MIND d Z C►- W ,ca r� Lr) .0101111I.. u_ � V� �o•oo�0000••a '�� •d OD � Z • � q V) Intloo 0 0 cem z W z Lr) N 0 VL_ E2:05 5 • TITLE • FRONT ELEVATION DETAILS DAVISc -ia J�l 19 BEWS DESIGN GKOVP 150 STATE STREET FAST OLDSMW FLORIDA 39677 813. 925.1300 TEL 813 .925.1800 FAX W W W.DAVISBEWS-COM TAMPA • DENVER EST. 1994 W d M 00 co o 000 ai ` V � MIND d Z C►- W ,ca r� Lr) .0101111I.. u_ � V� �o•oo�0000••a '�� •d OD � Z • � q V) Intloo 0 0 cem z W z Lr) N 0 VL_ E2:05 5 • TITLE • FRONT ELEVATION DETAILS - ---------------------- ----------------- ^ - I I I I — — -- --- — k I I I I I --------------------------�I f I I I I I I L _——�-----J I I I HATCHING INDICATES RECE55 IN TRUSSES FOR TRAY CLG. BELOW (TYP.) I I I I LuLLJ I I I L �a I C) I � I I I A T. I I I 4� I I I I I � I I I I IIFJ- y/4 I I I KNEE WALL I li I 4 I ROOF VENT REQUIREMENTS VENTILATION CALCULATIONS ATTIC AREA = 2737 SQ. FT. / 300 = 9.12 SQ. FT. X 144 = 1314 SQ. IN. HALF AT UPPER 2/3 ROOF VENTS = 656.88 SQ. IN. # UPPER 2/3 ROOF VENTS REQUIRED = 5 HALF AT LOW SOFFIT / EAVE VENTS = 656.88 SQ. IN. ACTUAL SOFFIT VENTILATION = 1147,80 SQ. IN. VENT CALCULATIONS BASED ON THE FOLLOWING * 144 SQ. IN. PER 4 FOOT OFF RIDGE VENT * 9.7 SQ. IN, PER LINEAR FOOT OF SOFFIT VENT G.C. VERIFY QUANTITY OF ROOF / SOFFIT VENTS REQUIRED, PER MANUFACTURER'S SPECIFICATIONS OF NET FREE AREA PER VENT. 11/2" THICK SAND FIN15H KEY5TONE r zo 623) I J1 DAVIS BEWS DESIGN GROVP uu TAMPA • DENVER. EST. 1994 I I I I I I I j II KNEE II II it I -- I WALL - - �. oJm SADDLE I �e I II I i II II I II I I II � I I I II I � � ,Ea N occ I Oco c z ov I � I # * TYP. REFER TO COVER 5-IFFT OVERHANG GENERAL NOTF5 FOR AT HIP ROOFING UNDERLA�MI;�NT (U.NQ.) ROOF PLAN REQUIREMENTS FOR ROOT= PITCHES LL55 THAN 4:13 SCALE: i.8'' _ 1'-0" 11/2" THICK SAND FIN15H KEY5TONE 3/4" THICK (IF APPLICABLE) RAI5ED SAND FIN15H TEXTURED BANDING NOTE: THI5 DETAIL 5HOW5 THE TYPICAL THICKNE55 OF ALL RA15ED TEXTURED FIN15H BANDING AND SAND FIN15HED KEYSTONES (WHERE APPLICABLE) IF THICKNE5515 TO BE DIFFERENT IT WILL BE CALLED OUT AT SPECIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.1 AND 45TM C 1063. THICKNE55 OF TEXTURED FINISH OVER FRAME APPLICATION TO BE PER F.B.C.R - 5TH EDITION (2014) 8103.6.2 AND 45TM C 92(o. TYP. CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND r OR SAND FINISH KEYSTONE SCALE: 3" - I'-0" C,Lf: AR OF)[ _Nk,; I, Iii is IN DWE'NG UNITS, WHERE THE OI LNN,u Or AN OPERABLE WINDOW 5 'LOCATED MORE 114N ') V HE5 ABOVE THE FIN151IED GRADE OR 5URFAGE lWE LOWEST PART OF TIH,_ CLEAR OPENING OF TIE WiNf-�OW 5H4LL BE A MINIMUM C;P 24 INCHES ABOVE THF F'Ni 7HED FLOOR OF THE ROOM IN WHICH THE WINDOW 15 0�''":ED. OPERABLE 5ECTION5 OF WINDOWS SNALL NOT PERMIT OPENING5 THAT ALLOW F455AGE OF 4 INCH 1)!4`FTER SPHERE WHERE SUCH OFFNING5 ARE I.,OCATED JI, ,H'N 24 INCHES OF THE FIN15E-ED N.00R PER F.B.C.R. - 5TH EDITION (2014) R312,2 WINDOW FALL PREVENTION DFVICE3 AND WINDOW GUARDS, WHERE FROVIDED, 5H4LL COMPLY WITH THE REQUIREMENTS OF A5TM F 2090 PER F.B.C.R. - 5TH EDITION (2014) 8312.2 <t d 40'-0" (VERIFY W/ TRUSS MANUF) SECTION AA SCALE: 1/6" - 14" 12 12 6 4INGLE ROOF T.O.M. T.O.M. EH TEXTURED 6, o FINISH 6, FIN15H FLOOR LINE _ _ _ _ _ _ _ _ _ FIN15H FLOOR LINE LEFT ELEVATION TOM SCALE: 1/8" = 14" 12 6 12 � Q 6 /SHINGLE ROOF -7 TEXTURED I—J FIN15H c0 * FINISH FLOOR LINE _ - - - TEMP. REAR ELEVATION SCALE: I/8" - I'-0" -•— 5HINGLE ROOF — 12 E6 12 Q 6 12 Q6 GRADE LINE (A55UMED) T.O.M. _ TEXTURED FIN15H b- FIN15H FLOOR LINE . GRADE LINE (A55UMED) 12 Q6 STUCCO T.O.M. 12 SHINGLE FIN15H 6 � ROOF —•- T.O.M. _ T,O.M, TYP. 4XTURED / TEXTURED eO RETURN * * FINISH 7 � FINISiN 7 AT 51DES TEMP. f FIN15H FLOOR LINE FIN15H FLOOR LINE GRADE LINE RIGHT ELEVATION (A55UMED) SCALE: 1/8" = 1'-0' ELEVATION "ME - MEDITERRANEAN' GARAGE RIGHT zo 623) I J1 DAVIS BEWS DESIGN GROVP z TAMPA • DENVER. EST. 1994 N' o w 04 co m . r- �. oJm V) LL. ua �.Eogco LLIX � � ,Ea N occ 3/4" THICK (IF APPLICABLE) RAI5ED SAND FIN15H TEXTURED BANDING NOTE: THI5 DETAIL 5HOW5 THE TYPICAL THICKNE55 OF ALL RA15ED TEXTURED FIN15H BANDING AND SAND FIN15HED KEYSTONES (WHERE APPLICABLE) IF THICKNE5515 TO BE DIFFERENT IT WILL BE CALLED OUT AT SPECIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.1 AND 45TM C 1063. THICKNE55 OF TEXTURED FINISH OVER FRAME APPLICATION TO BE PER F.B.C.R - 5TH EDITION (2014) 8103.6.2 AND 45TM C 92(o. TYP. CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND r OR SAND FINISH KEYSTONE SCALE: 3" - I'-0" C,Lf: AR OF)[ _Nk,; I, Iii is IN DWE'NG UNITS, WHERE THE OI LNN,u Or AN OPERABLE WINDOW 5 'LOCATED MORE 114N ') V HE5 ABOVE THE FIN151IED GRADE OR 5URFAGE lWE LOWEST PART OF TIH,_ CLEAR OPENING OF TIE WiNf-�OW 5H4LL BE A MINIMUM C;P 24 INCHES ABOVE THF F'Ni 7HED FLOOR OF THE ROOM IN WHICH THE WINDOW 15 0�''":ED. OPERABLE 5ECTION5 OF WINDOWS SNALL NOT PERMIT OPENING5 THAT ALLOW F455AGE OF 4 INCH 1)!4`FTER SPHERE WHERE SUCH OFFNING5 ARE I.,OCATED JI, ,H'N 24 INCHES OF THE FIN15E-ED N.00R PER F.B.C.R. - 5TH EDITION (2014) R312,2 WINDOW FALL PREVENTION DFVICE3 AND WINDOW GUARDS, WHERE FROVIDED, 5H4LL COMPLY WITH THE REQUIREMENTS OF A5TM F 2090 PER F.B.C.R. - 5TH EDITION (2014) 8312.2 <t d 40'-0" (VERIFY W/ TRUSS MANUF) SECTION AA SCALE: 1/6" - 14" 12 12 6 4INGLE ROOF T.O.M. T.O.M. EH TEXTURED 6, o FINISH 6, FIN15H FLOOR LINE _ _ _ _ _ _ _ _ _ FIN15H FLOOR LINE LEFT ELEVATION TOM SCALE: 1/8" = 14" 12 6 12 � Q 6 /SHINGLE ROOF -7 TEXTURED I—J FIN15H c0 * FINISH FLOOR LINE _ - - - TEMP. REAR ELEVATION SCALE: I/8" - I'-0" -•— 5HINGLE ROOF — 12 E6 12 Q 6 12 Q6 GRADE LINE (A55UMED) T.O.M. _ TEXTURED FIN15H b- FIN15H FLOOR LINE . GRADE LINE (A55UMED) 12 Q6 STUCCO T.O.M. 12 SHINGLE FIN15H 6 � ROOF —•- T.O.M. _ T,O.M, TYP. 4XTURED / TEXTURED eO RETURN * * FINISH 7 � FINISiN 7 AT 51DES TEMP. f FIN15H FLOOR LINE FIN15H FLOOR LINE GRADE LINE RIGHT ELEVATION (A55UMED) SCALE: 1/8" = 1'-0' ELEVATION "ME - MEDITERRANEAN' GARAGE RIGHT • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 X co 623) I J1 DAVIS BEWS DESIGN GROVP U wo TAMPA • DENVER. EST. 1994 N' N0 Mh � 04 co m . r- �. oJm V) LL. 0 0 ro = r• �.Eogco �=L �OI � � ,Ea N occ Oco c z ov • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 W �» co •- ac 00 on wO z CD a Lr) 9 L �®���e�rrrrrrr� co lz L L w S CD �c ° Coo 0 a tz: 2� .'i Z •• z W V 0�Z Lr) o N 2055 • TITLE • SIDE ELEVATIONS ROOF PLAN BUILDING SECTION DETAILS II 623) I J1 DAVIS BEWS DESIGN GROVP 150 STATE STR.E..ET EAST 01 DSMAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.CAM TAMPA • DENVER. EST. 1994 W �» co •- ac 00 on wO z CD a Lr) 9 L �®���e�rrrrrrr� co lz L L w S CD �c ° Coo 0 a tz: 2� .'i Z •• z W V 0�Z Lr) o N 2055 • TITLE • SIDE ELEVATIONS ROOF PLAN BUILDING SECTION DETAILS II #3 _._. BUILDING WRAP TO GO OVER FLASHING FLASHING TO BE FLEXIBLE SELF ADHESIVE TYPE (MIN 6" WIDE) PRECAST LINTEL TYPICAL FLASHING AT PRECAST AND EXTERIOR SHEATHING hWUI- IVIA I tKIAL NtK ELEVATIONS WITH APPROVED UNDERLAYMENT (REFER TO COVER SHEET) PRE-ENGINEERED ROOF TRUSSES AT 24" O.C. HURRICANE STRAP PER ROOF FRAMING PLAN OIL BRG. HGT ALUM. DRIP EDGE 2x6. FASCIA VENTED ALUM. SOFFIT SHEATH & EXT. FINISH WINDOW FLASHING AS REQ'D 1x4 WINDOW TRIM DBL. HEADER TYPICAL WINDOW AND SLIDING GLASS DOOR "Z" FLASHING DETAIL OPTION - A FLASHING WOODEN SIDING SILL PLATE SEE NOTE #2 ---J WALL SHEATHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE 3. INSTALL SILL FLASHING AS SHOWN ABOVE 4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT 5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS TYPICAL FLASHING DETAIL AT SILL PLATE TIE-IN WITH WEATHER RESISTIVE BARRIER: 1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH FLASHING TO FORM WATER SHEDDING LAPS 2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW FOR FLASHING INSTALLATION 4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER 5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE FLASHING 15/32 O.S.B. SHEATHING BUILDING WRAP BEYOND PROVIDE SELF ADHERED Z FLASHING UNDER S.G.D. AS RUBBER MEMBRANE BEYOND i SHOWN, PROVIDE 4" -1" BEAD OF CONST, ADHESIVE TO BE APPLIED i CAULK/SEALANT OR SOLDER UNDER THRESHOLD OF DOOR BETWEEN PAN FLASHING AND RETURN UP JAMB 6". USE AND DECK FLASHING. LIQUID NAIL BRAND OR EQUAL i EXTERIOR FINISH WATER PROOF CAULKING PER BUILDER -7 .t PROVIDE SELF ADHERED FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" WATERPROOF MEMBRANE 1 2X12 #2 SYP CONT LEDGER W/ (4) 1/4" X 4" LAG SCREWS �) SPACED EVENLY @ 24" O.C. MAX ( EA. FLOOR TRUSS) -- USP HTA20 STRAP EA. JOIST - � TEXTURED CEMENT PLASTER FINISH TYPICAL DOOR FLASHING AT BALCONY EXTERIOR SHEATHING i �F�TyF FOLD UP WEATHER R RESISTIVE BARRIER & TEMPORARILY SECURE / ,SFS/ST ��0 \ eqR P 0P SILL PLATE (SEE DETAIL B O C2) FOR OPTIONS) 0P� TYPICAL SLIDING GLASS DOOR FLASHING DETAIL MECHANICALLY FASTEN AS NECESSARY IN CORNERS THROUGH FLASHING WEATHER RESISTIVE BARRIER TAPE (ASSEMBLED FLASHING WINDOW) HEAD FLASHING TIE-IN INSTRUCTIONS: WEATHER RESISTIVE BARRIER DO NOT FLASH OVER BOTTOM �l NAILING FLANGE `2) WEATHER RESISTIVE BARRIER CORNER PATCH FLASHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS 3, MECHANICALLY FASTEN AS NECESSARY FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE EXTERIOR SHEATHING SILL PLATE FLASHING NOTES: 1. CUT, FOLD UP & TEMPORARILY SECURE WEATHER RESISTIVE 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) BARRIER ABOVE HEADER TO ALLOW FOR FLASHING 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW INSTALLATION SILL PLATE 2. INSTALL HEAD FLASHING UNDER 3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS WEATHER RESISTIVE BARRIER 4. INSTALL FLASHING AND WEATHER RESISTIVE 3. FOLD WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS BARRIER BACK OVER HEAD FLASHING AND SEAL WITH TAPE TYPICAL WINDOW FLASHING DETAIL PROVIDE SELF ADHERED FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" WALL COVERING 2X4'S @ 16" O.C. BRG EXT WALL FLASHING TO EXTEND 36" 7/16" O.S.B. SHEATHING BUILDING WRAP BEYOND FLASHING. CEMENT PLASTER STOP WATERPROOF MEMBRANE 20" FLOOR TRUSS SEE STRUCTURAL FOR CONNECTORS 24" FLOOR TRUSS SEE STRUCTURAL 8' CMU BLOCK TYPICAL FLASHING AT BALCONY EXTERIOR FINISH PER BUILDER PROVIDE FLASHING BOOT AT POSTS WATERPROOF MEMBRANE 7/16" O.S.B. SHEATHING FLASHING. 2X8 TRIM BOARD STUCCO "J" MOLD 7/16" O.S.B. SHEATHING TEXTURED CEMENT PLASTER FINISH 2014 FBRC SECTION R703 EXTERIOR COVERING EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.8. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO THE EXTERIOR WALL THAT ENTERS THE ASSEMBLY. PROTECTION AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED IN ACCORDANCE JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 • 9-ju-) L_ DAVIS B EWS DESIGN GROVP • EST. 1994 c- R703.2 WATER -RESISTIVE BARRIER x N = 00 LO C 0 rtoo mom 0 -i N - ASTM D 226 FOR TYPE 1 APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF V+ 0 W ALL EXTERIOR WALLS. SUCH MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER cli NM N N r Ln v o gu. V >;Jc to* L °1)L. THAN 6 INCHES (152 MM). THE APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF WALLS AND 0 0ro =10 J V 0 pis TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE O �Co ```s'N' `L�•eee....ee®ee e,�d 3�El ��N0 a`e r I- N I` R703.8 FLASHING O 41 Z = u. a Z .: APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT �•�� s • O� JOB NUMBER 26002.235 CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 WITH SECTION R702.7 OF THE CODE. ui 9-ju-) L_ DAVIS B EWS DESIGN GROVP 150 STATE STREET EAST OUXMW FLORIDA 34677 813. 925. 1300 TEL 813. 925.1800 FAX W W W.DAVISBEWS.COM TAMPA • DENVER EST. 1994 c- WITH SECTION R702.7 OF THE CODE. ui R703.2 WATER -RESISTIVE BARRIER N = 00 ONE LAYER OF APPROVED WEATHER -RESISTANT MATERIAL, FREE FROM HOLES AND BREAKS, COMPLYING WITH mom o ° ASTM D 226 FOR TYPE 1 APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF C) W ALL EXTERIOR WALLS. SUCH MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER Ln v o gu. THE LOWER LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, MATERIAL SHALL BE LAPPED NOT LESS to* THAN 6 INCHES (152 MM). THE APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF WALLS AND arc al pis TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE ```s'N' `L�•eee....ee®ee e,�d EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1. a`e r R703.8 FLASHING = u. a Z .: APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT �•�� s • O� ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING �� ` •e•'•••.e..• �' COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711411 EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND z CONTRACTION, ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL ND EXT V E TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS OR FOR APPLICATIONS NOT T ADDRESSED IN THE FENESTRATION MANUFACTURER'S, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOWS AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. 1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. Ln 1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. 1.4 IN ACCORDANCE WITH FMA/AAMA 100 FMA/AAMA 200 FMA/WDMA 250 OR FMA/AAMA/WDMA 300. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 0 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. J 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 2055 e 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. FLASHING DETAILS N.T.5, e TI TLE • FLASHING DETAILS • SHEET3A3 • 5PEATHING TEXTURE FIN15H COAT BROWN COAT 5CRATCH COAT 5ELF-FURRING LATP TWO LAYERS WRB WEEP 5CREED TERMINATE 5ELF ADPE51VE FLA5PING AT LOWER N05E OF 1115. 5ELF ADHESIVE FLASHING MA50NRY BLOCK WALL WEEP SCREED AT MID -WALL MASONRY TO WOOD DETAIL EXTERIOR SHEATHING REFER TO TECHNICAL / LETTER ON CHEMICAL / COMPATIBILITY ° SELF -ADHERED FLASHING SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR - 3l4"-1" BEAD OF CONSTR, SHEATHING ADHESIVE TO BE APPLIED UNDER -- - -. THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND I OR EQUAL WEATHER PROOF CAULKING WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm: 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT, FIN. BUILDING PAPER 7--- WIRE LATH SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE FLASHING JAMB & HEAD THROUGH SELF -ADHERED FLASHING, SEE FLASHING— SELF ADHERED FLASHING FLANGED WINDOW (SEE DETAIL WP01) SCORED _ \` RELEASE PAPER SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE VERTICALLY FROM ADHESIVE AS SHOWN) BOTTOM OF / THRESHOLD SECTION -A (SEE DETAIL WP02) / \ SELF -ADHERED FLASHING NAILING FLANGE SELF -ADHERED FLASHING 21 DO NOT FLASH OVER i / / v- SEAL TOPS OF JOISTS *INSTALL SELF -ADHERED FLASHING IN ORDER AS SHOWN BY NUMBERS BOTTOM NAILING UNDER DECKING **INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER FLANGE (SEE DETAIL WP07) SHEDDING LAPS SELF -ADHERED FLASHING SELF -ADHERED FLASHING HALF ROUND WINDOW EXTERIOR DOOR WITH DECK WALL SHEATHING ��\!%/%'� ASPHALT SEALANT: ��ii/'ir'l- CONT. GALV. "L" EXTEND MIN. OF 6" ������ FLASHING PER TEXTURED; PAIN' " OUTSIDE OF FLASHING / I MANUFACTURES EXTER. WALL FIF j SPECIFICATIONS ROOF CRICKET: MIN: 3:12 SLOPE PLASTER STOP — CRICKET AS (REQUIRED AT SPECIFIEDALL LEVEL VALLEY -VERTICAL WALL BEAUTY STRIF BY PLAN LOCATIONS) / AT ENTRY SHINGLE OVEI 6 / - FLASHING W/ ' \ CONT. GALV. DIVERTER FLASHING PER MANUFACTURI FLASHING \\ Miys \ �� y / SPECIFICATIOI `�\ OVER ROOF \ ROOF MATERIAL PER SHINGLES W/ ELEVATIONS WITH APPROVED NOTE: THIS DETAIL IS REQUIRED DRIP EDGE AT ALL VERTICAL WALL INTERSECTIONS '.,\\ UNDERLAYMENT (REFER TO FASCIA COVER SHEET) WITH ROOF VALLEYS & ROOF CRICKETS. PRE-ENGINEERED ROOF c" SELF -ADHERED FLASHING INSIDE CORNER C`\ ASPHALT BASED SEALANT APPLIED BEHIND FLASHING AND EXTENDING A MINIMUM OF 6" ABOVE VERTICAL RISE OF FLASHING AT KNEEWALL SEALANT HIND DETAILS TRUSSES AT 24" O.C. BEAUTY STRIP ROOF SHINGLE OVER FIGURE 1: FLASHING INSTALLATION FLASHING W/ TAR FLASHING INSTALLATION CONT. GALV "L" WHERE ROOF MEETS VERTICAL WALL FLASHING PER TEXTURED, PAINTED MANUFACTURES EXTERIOR WALL FINISH SPECIFICATIONS :° .•.:°° :°. ;.°o ..°. ��.^.. OVER ROOF SHINGLES W/ TAR —HOLD EXTERIOR FINISH 2" ABOVE y,rf'`°y,�.• ROOF SHINGLE PER oGe " - \ CONTRACT a FLASHING CAULKING p ROk ' \a TYPICAL ROOF TO Fq ON 0 WALL FLASHING DETAIL RAKE METAL DRIP EDGE FIGURE 2: WALL FINISH ASPHALT SEALANT: EXTEND MIN. 6" ABOVE FLASHING 6 TO 12" PER PLAN 6" HIGH \ \� PEC'S. DIVERTER 6 FLASHING j \ GALV. 'L' FLASHING TYPICAL. ROOFING FELT \ DRIP EDGE FASCIA FIGURE 3: CORNER DETAIL TO BE OVER —�� LINE VALLEY BY CENTERING 36" WIDE UNDERLAYMENT AT U-1 CERTAINTEED WINTERGUARD GABLE ENDS WATERPROOFING SHINGLE UNDERLAYMENT OR EQUIVALENT DIRECTLY TO DECK SAVE 7" PIECES TO USE IN 5TH COURSE EMBED EACH SHINGLE IN A 2" DO NOT NAIL WITHIN 6" OF i WIDE STRIP OF ASPHALT VALLEY CENTERLINE I I RAGING CEMENT. - CUT 2" DIAGONALLY OFF UPPER CORNER OF TRIMMED SHINGLE SCUT SHINGLES 2" BACK FROM VALLEY CENTERLINE i' REMOVE FIGURE 4: VALLEY DETAIL METAL DRIP EDGE TO BE UNDER UNDERLAYMENT AT ROOF EAVES - RooF OE�K S/vol\_ M�N� \ \ A;100 SPP N 5�N Go�R4 N ooVRSE 3�a GOVRGo0RSE \gE 2No 1ST 00 \ • _/ 29 � e 2$„ EAVES 7, FIRST STARTER SHINGLE EXTEND THE SHINGLES OVER THE RAKE AND EAVES ABOUT 1/2" IF DRIP EDGE IS USED, OR ABOUT 3/4" IF NO DRIP EDGE IS USED. 7/8" CEMENT PLASTER 7/8" CEMENT PLASTER IN IN ACCORDANCE WITH ACCORDANCE WITH ASTMC926 ASTMC926 WEATHER RESISTIVE BOTTOM OF BARRIER � DOOR ROUGH OPENING WOOD FRAME CONSTR. MATERIAL W/ METAL LATH IN SELF -ADHERED FLASHING 3/4"-1" BEAD OF CONSTR. BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND \ OR EQUAL WEATHER PROOF CAULKING 7/16" O.S.B. II 4 ,' SELF -ADHERED FLASHING SEAL TOPS OF JOISTS SHEATHING UNDER DECKING SUBFLOOR (SEE DETAIL WP07) --- - RIM JOIST SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR - 3l4"-1" BEAD OF CONSTR, SHEATHING ADHESIVE TO BE APPLIED UNDER -- - -. THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND I OR EQUAL WEATHER PROOF CAULKING WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm: 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT, FIN. BUILDING PAPER 7--- WIRE LATH SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE FLASHING JAMB & HEAD THROUGH SELF -ADHERED FLASHING, SEE FLASHING— SELF ADHERED FLASHING FLANGED WINDOW (SEE DETAIL WP01) SCORED _ \` RELEASE PAPER SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE VERTICALLY FROM ADHESIVE AS SHOWN) BOTTOM OF / THRESHOLD SECTION -A (SEE DETAIL WP02) / \ SELF -ADHERED FLASHING NAILING FLANGE SELF -ADHERED FLASHING 21 DO NOT FLASH OVER i / / v- SEAL TOPS OF JOISTS *INSTALL SELF -ADHERED FLASHING IN ORDER AS SHOWN BY NUMBERS BOTTOM NAILING UNDER DECKING **INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER FLANGE (SEE DETAIL WP07) SHEDDING LAPS SELF -ADHERED FLASHING SELF -ADHERED FLASHING HALF ROUND WINDOW EXTERIOR DOOR WITH DECK WALL SHEATHING ��\!%/%'� ASPHALT SEALANT: ��ii/'ir'l- CONT. GALV. "L" EXTEND MIN. OF 6" ������ FLASHING PER TEXTURED; PAIN' " OUTSIDE OF FLASHING / I MANUFACTURES EXTER. WALL FIF j SPECIFICATIONS ROOF CRICKET: MIN: 3:12 SLOPE PLASTER STOP — CRICKET AS (REQUIRED AT SPECIFIEDALL LEVEL VALLEY -VERTICAL WALL BEAUTY STRIF BY PLAN LOCATIONS) / AT ENTRY SHINGLE OVEI 6 / - FLASHING W/ ' \ CONT. GALV. DIVERTER FLASHING PER MANUFACTURI FLASHING \\ Miys \ �� y / SPECIFICATIOI `�\ OVER ROOF \ ROOF MATERIAL PER SHINGLES W/ ELEVATIONS WITH APPROVED NOTE: THIS DETAIL IS REQUIRED DRIP EDGE AT ALL VERTICAL WALL INTERSECTIONS '.,\\ UNDERLAYMENT (REFER TO FASCIA COVER SHEET) WITH ROOF VALLEYS & ROOF CRICKETS. PRE-ENGINEERED ROOF c" SELF -ADHERED FLASHING INSIDE CORNER C`\ ASPHALT BASED SEALANT APPLIED BEHIND FLASHING AND EXTENDING A MINIMUM OF 6" ABOVE VERTICAL RISE OF FLASHING AT KNEEWALL SEALANT HIND DETAILS TRUSSES AT 24" O.C. BEAUTY STRIP ROOF SHINGLE OVER FIGURE 1: FLASHING INSTALLATION FLASHING W/ TAR FLASHING INSTALLATION CONT. GALV "L" WHERE ROOF MEETS VERTICAL WALL FLASHING PER TEXTURED, PAINTED MANUFACTURES EXTERIOR WALL FINISH SPECIFICATIONS :° .•.:°° :°. ;.°o ..°. ��.^.. OVER ROOF SHINGLES W/ TAR —HOLD EXTERIOR FINISH 2" ABOVE y,rf'`°y,�.• ROOF SHINGLE PER oGe " - \ CONTRACT a FLASHING CAULKING p ROk ' \a TYPICAL ROOF TO Fq ON 0 WALL FLASHING DETAIL RAKE METAL DRIP EDGE FIGURE 2: WALL FINISH ASPHALT SEALANT: EXTEND MIN. 6" ABOVE FLASHING 6 TO 12" PER PLAN 6" HIGH \ \� PEC'S. DIVERTER 6 FLASHING j \ GALV. 'L' FLASHING TYPICAL. ROOFING FELT \ DRIP EDGE FASCIA FIGURE 3: CORNER DETAIL TO BE OVER —�� LINE VALLEY BY CENTERING 36" WIDE UNDERLAYMENT AT U-1 CERTAINTEED WINTERGUARD GABLE ENDS WATERPROOFING SHINGLE UNDERLAYMENT OR EQUIVALENT DIRECTLY TO DECK SAVE 7" PIECES TO USE IN 5TH COURSE EMBED EACH SHINGLE IN A 2" DO NOT NAIL WITHIN 6" OF i WIDE STRIP OF ASPHALT VALLEY CENTERLINE I I RAGING CEMENT. - CUT 2" DIAGONALLY OFF UPPER CORNER OF TRIMMED SHINGLE SCUT SHINGLES 2" BACK FROM VALLEY CENTERLINE i' REMOVE FIGURE 4: VALLEY DETAIL METAL DRIP EDGE TO BE UNDER UNDERLAYMENT AT ROOF EAVES - RooF OE�K S/vol\_ M�N� \ \ A;100 SPP N 5�N Go�R4 N ooVRSE 3�a GOVRGo0RSE \gE 2No 1ST 00 \ • _/ 29 � e 2$„ EAVES 7, FIRST STARTER SHINGLE EXTEND THE SHINGLES OVER THE RAKE AND EAVES ABOUT 1/2" IF DRIP EDGE IS USED, OR ABOUT 3/4" IF NO DRIP EDGE IS USED. 7/8" CEMENT PLASTER 7/8" CEMENT PLASTER IN IN ACCORDANCE WITH ACCORDANCE WITH ASTMC926 ASTMC926 UNPERFORATED VULCUM CAULK BOTTOM FLANGE 7/8" JOINT ONLY \ WEEP SCREED MAINTAIN APPROVED WEATHER -RESISTANT BOTTOM OF APPROVED WEATHER -RESISTANT WEEP SCREED MATERIAL W/ METAL LATH IN 1 1/2" TO 2" MATERIAL W/ METAL LATH IN ABOVE ROOF ACCORDANCE WITH ASTMC1063 SHEATHING ACCORDANCE WITH ASTMC1063 J N - BUILDING PAPER BUILDING PAPER \ WILL NEED TO BE 7/16" O.S.B. II 7/16" O.S.B. ,' SHEATHING d SHEATHING ' La ..= =.J cm KEEP TOP EDGE OF WEEP METAL SCREED 2" BELOW TOP OF ' FLASHING BLOCK . O 0 =roe, u.cm 3 1/2.. o�m i UNPERFORATED VULCUM CAULK BOTTOM FLANGE 7/8" JOINT ONLY \ WEEP SCREED MAINTAIN METAL FLASHING 3-1/2 BOTTOM OF UNPERFORATED FLANGE 7/8" WEEP SCREED WEEP SCREED 1 1/2" TO 2" C ABOVE ROOF 1/2" CEMENTITIOUS SHEATHING DECORATIVE FINISH J N - ® ®®�®®® ALL INSIDE AND o°�®° ®® OUTSIDE CORNER ' WILL NEED TO BE MITER CUTAND II CAULKED ALL BUTT t mvwcry i rLMO i cn IN JOINTS NEED TO BE ACCORDANCE WITH ®°q®� ®®®°� EMBEDDED IN ASTMC926 OVER WOOD " ®°®•® ®• ° °�° ° SEALANT USING 2ND FLOOR VULCUM CAULK FOR ALL / CEMENT PLASTER OVER BLOCK 1 ST FLOOR NOTE: THE BUILDING PAPER AND METAL LATH MUST BE INSTALLED OVER THE TOP OF THE WEEP SCREED. >UBLE JOIST AM BELOW 1/2" CEMENT PLASTER FINISH 2 1/2" PERFORATED FLANGE 1/2" WEEP SCREED INSTALL BOTTOM EDGE OF SLAB WEEP SCREED 1" BELOW FINISH FLOOR OPTIONAL DETAIL WEEP SCREED DETAIL SCALE: NOT TO SCALE SELF -ADHERED - FLASHING PATCH )HERED FLASHING THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND FLASHING WATERPROOFING METHODS TO BE USED. N.T.5. • J08NUMBER 26002.235• CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 X ro 150 STATE STREET EAST OLDSMW FLORIDA 34677 813. 925 .1300 TEL 813.92.5.1500 FAX W W W.DAVISBEW&COM TAMPA • DENVER C Ubo o J N - ' 'nN 0N�M w/ d La ..= =.J cm i.`�5L• 0 0 �2 0 . O 0 =roe, u.cm o�m Z_� • J08NUMBER 26002.235• CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16 • TITLE • FLASHING DETAILS • SHEET • 410 j DAVIS BEWS DESIGN GROUP 150 STATE STREET EAST OLDSMW FLORIDA 34677 813. 925 .1300 TEL 813.92.5.1500 FAX W W W.DAVISBEW&COM TAMPA • DENVER EST. 1994 ( � • TITLE • FLASHING DETAILS • SHEET • DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER P WEATHERPROOF DUPLEX OUTLET .F.,. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH 13 THREE-WAY SWITCH 14 FOUR-WAY SWITCH $ D DIMMER SWITCH + CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE P� LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLUORESCENT LIGHT FIXTURE ELECTI CAL T' g EXHAUST FAN ;p. EXHAUST FAN/LIGHT COMBINATION n ELECTRIC DOOR OPERATOR (OPTIONAL) �-� EST. 1994 CHIMES (OPTIONAL) PUSHBUTTON SWITCH (OPTIONAL) TYR 14 AND '2 COPPER TO CARBON MONOXIDE DETECTOR ® SMOKE DETECTOR 5p a� SMOKE / CARBON MONO, COMBO DETECTOR PANEL TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 0 THERMOSTAT WATER HEATER ELECTRIC METER = ELECTRIC PANEL SERVICE BY DISCONNECT SWITCH ro T� 0 000 SPEAKER (OPTIONAL) --- ROUGH -IN FOR OPT. CEILING FAN �� CEILING MOUNTED INGANDESGENT LIGHT FIXTURE W/ G J ROUGH -IN FOR OPT, CEILING FAN NOTES - I. PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTERRUPTERS IGF.() AS INDICATED ON PLANS OR AS ITEM NO. 4 AND 5 BELOW INDICATES. 2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHED FLOOR: SWITCHES.... 42" OUTLETS ..... 14" TELEPHONE ... 14" (UNLESS ABV COUNTERTOP) TELEV15ION... 14" 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 4, ALL 15A AND 20A RECEPTACLES IN SLEEPING ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ALAS WILL REQUIRE A COMBINATION TYPE AF.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER N.E.C. 2011406.12 AND 406.13 5. ALL 15A AND 20A 120V RECEPTACLES LOCATED IN THE GARAGE AND UTILITY ROOMS SHALL BE GF.G.I. PROTECTED (GRP 6. IT 15 THE RE5PON51BILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL, WORK IS IN FULL COMPLIANCE WITH NRP.A.10, N.E.C. 2011, FB.C.R. - 5TH EDITION (2014), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. 1. EVERY BUILDING HAVING A FOSSIL -FUEL -5UI;lING HEATER OR APPLIANCE, FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CAR50N MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. 8, ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACKUP. COMBINATION SMOKE/CARSON MONOXIDE ALARMS SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY, NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER COMPANY, MICROWAVE OUTLET +14" 220v. G.C. VERIFY UNDER CABINET LIGHTING 4/0 ALU. CABLE MAIN DISCONNECT METER A/C DISC. COMBO - SQUARE D �-� EST. 1994 Lo C 0 o TYR 14 AND '2 COPPER TO REFER TO FLOOR INSIDE LIGHTS AND OUTLETS PLAN FOR NOTED MAIN DISC, PANEL AMPS. REQUIRED 90 COPPER TO WATER HEATER UNDERGROUND "8 COPPER TO RANGE SERVICE BY ro T� 0 000 POWER COMPANY --- $4 COPPER TO 5/8" GROUND ROD ALSO SERVICE TO BE BONDED TO FOOTING STEEL ELECTRICAL RISER DIAGRAM NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER COMPANY, MICROWAVE OUTLET +14" 220v. G.C. VERIFY UNDER CABINET LIGHTING • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16(nowC) 2055 x FAX W W W.DAVISBEWS.COM TAMPA •DENVER. �-� EST. 1994 Lo C 0 o 0 ,� CoN Co N�� �. ?JM Lo L ���• ro T� 0 000 FL L W .cN ,� � In h Z��° • JOB NUMBER 26002.235 • CAD FILE NAME LOT 25 ISSUED 10-06-16 REVISED 10-21-16(nowC) 2055 FAX W W W.DAVISBEWS.COM TAMPA •DENVER. �-� EST. 1994 1.1 W 0 � z m � O � � O `r' O N J0ve ou DAMS eEWS DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST QLDSMAR, FLORIDA 34677 813.925.1300 TEL 813. 925.1800 ELECTRICAL PLAN GARAGE RIGHT4 • TITLE • ELECTRICAL PLAN COACH • SHEET • OPT. \ / OPT. LIGHTING LIGN? Wj GENERAL NOTES METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD INDEX OF D RAW I N G S IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, W FOUNDATIONS METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL Q SOIL TO BE COMPACTED TO AT LEAST 95% UNDER SLABS AND UNDER FOOTINGS OF PRESSURE HAVE THE TREATEDAPPROPRIATE ACOATING THEFOR USE W (IGH THE DIFFERENT TYPESOF SHEET SHEET TITLE MINIMUM BEARING CAPACITY 2000 PSF MAX. DRY DENSITY DETERMINED BY ASTM- 1557 (MODIFIED PROCTOR) 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BE A MINIMUM MIG50 ZINC COATING - -- -- - - - -- -- TERMITE TREATMENT 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE S1 STRUCTURAL NOTES THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE PREVENTION OF (NON-DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT (BORACARE) MAY BE USED, 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE S2 FOUNDATION PLAN IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA PRESERVATIVE WOOD TREATER. DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. CAST IN PLACE CONCRETE 4 STAINLESS TREATED CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES OF S3 DOWEL PLACEMENT PLAN PRESSURE z 1 ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS PREFABRICATED WOOD TRUSSES O OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR +S4 ROOF FRAMING PLAN ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT S4.1 NOTES &CONNECTOR LEGEND � 2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY i U CONFORMING TO ASTM A-615 GRADE 40. REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE S5 LINTEL- PLAN .r U o W WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE 0 WITHIN THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS AND SD1 FOUNDATION DETAILS o 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE STRUCTURAL PLANS FOR MORE INFO. REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO S D2 GENERAL DETAILS � DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI 301. BY COMPONENTS AND CLADDING METHOD U.N.NO. BY TRUSS ENGINEER OF RECORD 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING 3, PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST SD3 GENERAL DETAILS BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 24 LAP EXCLUDING BEND EDITION OF ANSI TPI 1. c AT EACH END SHALL BE PROVIDED. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQ'D BY TRUSS MANU. U.N.O. S D4 GENERAL DETAILS �' 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE BAR DIAMETERS. 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF STRUCTURAL STEEL 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY 1. MATERIAL SPECIFICATIONS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 50, CENTER TO UPPER 1/3 OF THE SLAB. TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. Fy=50 KSI TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI PIPE STEEL: ct> BOLTS AND THREADED RODS TRUSS DESIGN LOADS : ASTM A53, TYPE E OR S, Fy = 35 KSI ALL OTHER STRUCTURAL &MISC. STEEL: O uj 1. ALL BOLTS & THREADED RODS TO BE ASTM A307 OR BETTER (U.N.O.) TOP CHORD: Lr = 16 PSF A36 Fy=36 KSI. �,� 4e''i, STEEL BOLTS LESS THAN ONE-HALF-INCH (12.7 mm) DIAMETER DL = 7 PSF (SHINGLE TYPE ROOF COVER) 2. STRUCTURAL CONNECTIONS: ALL STRUCTURAL BOLTS TO BE A325N U.N.O. ALL r.• �,, 00 2. USED AS FASTENERS FOR PRESSURE PRESERVATIVE-TREATED WOOD SHALL DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) A325N BOLTS SHALL BE BROUGHT TO A "SNUG-TIGHT" CONDITION , AS DEFINED u. x Y o BE OF HOT-DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, DL = 14 PSF (TRUSS OVERBUILD)IN THE SPECIFICATION. SLIP CRITICAL (SC) BOLTS MUST BE��FULLY TENSIONED : l = Z SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH BOTTOM CHORD: DL = 5 PSF ASTM A 153. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE MINIMUM FLOOR DESIGN LIVE LOADS: PER SPECIFICATION STRUCTURAL BOLTS SMALLER THAN 5/8 DIA. TO BE A307 THREADED ROD SHALL CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL 4 `p J 3 COAPERTINGED TO BE WEIGHTS IN ACCORDANCELWITDEPOSITED H ASTM B 6195, CLLASSDSTEEL 55, MINIMUM. B) BALCONIES 40 PSF 60 PSF / 100 PSF (WHEN BALCONY EXCEEDS 100 SQ FT) CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM MASTER U PDATE�7 '• �` LU A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINFORCEMENT •' ��o`*e Z MASONRY WALL CONSTRIVCTION C) DECKS = 40 PSF �, ,,� ��� Q 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, D) STAIRS = 40 PSF SHOP DRAWINGS TO BE PROVIDED TO ENGINEER OF RECORD BEFORE ✓,00 'Mr`; P `. p FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - NUMBER DATE DESCRIPTION INTIALS °'/°"" 00 m CONFORMING TO ASTM C90, WITH A MINIMUM NET COMPRESSIVE STRENGTH OF E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE 16" UNO. LL 2000 PSI (f'm = 1900 PSI) MINIMUM FLOOR DESIGN DEAD LOADS:01 15 PSF = 3. SUBMIT SHOP DRAWINGS INDICATING ALL SHOP AND ERECTION DETAILS 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 A) FLOORS INCLUDING PROFILES SIZES SPACING AND LOCATIONS OF STRUCTURAL CREATED ELEV. FC, NC, ME, & NCII w/ GARAGE OPTIONS, OPT BED 4 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 1". B)BALCONIES = 15 PSF MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 1 5/7/2015 AND MINOR OPTIONS EA ll 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE GENERAL LOADING: 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER COLOR AS DIRECTED V OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. ATTIC WITHOUT STORAGE = 10 PSF ( O / ATTIC WITH LIMITED STORAGE = 20 PSF BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY-ON FIRE 5. VERT. REINF. SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF PROTECTION. COARSE GROUT AND GRADE 40 STEEL. REINFORCEMENT SHALL BE PLACED IN THEw Moly GUARDRAILS IN-FILL COMPONENTS = 50 PSF 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY P� ^^ O bJ ch CENTER OF THE MASONRY CELL WITH MIN 1/2" CLEARANCE TO INSIDE FACE. GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND G H Ipll'I fyl� N 6. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP & BOTTOM & ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DRAWINGS SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. AT A MAX. SPACING OF 8'-0" U.N.O. -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA a 7. REINFORCING STEEL SHALL BE LAPPED PER TABLE BELOW U.N.O. ON DRAWINGS. RECOMMENDATIONS FOR MIN. 7/16"OSB SHEATHING -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD 0 ROOF HIP/RIDGE TO PREVENT r"� O O 0 REBAR SIZE MIN. LAP SPLICE LENGTH SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS LESS THAN 2FT). d w ,� BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS ® 12" O.C. MAX & 4" FROM EA. END. NOTE: uta ti4 4= z #5 25 PLYWOOD EDGES ® HIP CORNERS REQ. MIN 2x4 SYP #2 BLOCKING w/ (3) 12d TOENAILS EA. END. tis�G ami #6 30" -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45' FROM VERT. TO EA. TRUSS 0,9 U #7 35 MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN 0 10'-0" MAX AND EQUALLY con SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP GIRDER AND / OR o 0� 8. HOOKS AT THE TOP & BOTTOM OF VERT. REINF. BARS TO BOND COURSE & (4) BAYS AFTER GABLE END BRACING. SEE BCSI-83 SECTIONS 1, 2 AND 3 FOR ADDITIONAL ROOF 0 FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND PLANE PERMANENT BRACING REQUIREMENTS. 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING PERPENDICULAR pa"Q Im ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS DESIGN DRAWINGS. ATTACH 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST ONE TRUSS SPACE (24") PLUS 6" 11. PROVIDE GROUT STOPS BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP MIN PAST BOTTOM CHORD. OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO CELLS -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS AS INDICATED �^ BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. ON TRUSS SHOP DRAWINGS & BCSI-B3. VJ 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING ("T" BRACING MAY BE USED I.L.O. PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB W CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (SEE WEB REINFORCEMENT TABLE WITHIN BCSI-B3). Z 13. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d c Cn U CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318 LATEST EDITION 5.11.1 TOENAILS REQ D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND INDICATED O W J o d 14. DURING CONCRETE POURS, THE CONTRACTOR TO ADEQUATELY VIBRATE THE FILLED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12"TALL: 2x4 SYP #2 BEHIND THE TRUSS o CELL WITH EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN BOTTOM TO TOP W/ (2) 12d P ` 06 W d M E CONSOLIDATION. NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) Q n v� u - m WOOD CONSTRUCTION DIAGONAL BRACING REQUIRED AT CLB PER BCSI-B3. DESIGN PRESSURES Z U ~ �- 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NEPA NATIONAL DESIGN H v) o " 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS WORKING POINTS BEARING O w z CO POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL J U) X z a' o 8 P SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) WIND DESIGN LOAD INFORMATION o O a BEARING WALLS. SHEAR WALLS AND MISC. BRACING MEMBERS AND ALL TRUSS TO TRUSS HANGERS. :DQ �' " 2. ALL EXTERIOR WOOD STUD WALLS, WIND SPEED (ULTIMATE) 139 mph Cn 0 ►- P w w o STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), FIELD REPAIR NOTES WIND SPEED (ALLOWABLE) 108 mph Z q a w z o SHALL BE SPRUCE- PINE-FIR OR EQUIVALENT. NO. 2 GRADE SHALL BE USED WIND EXPOSURE B OU 02 o � a a 1. OMITTED REBAR REGARDLESS OF SPECIES. U.N.Q. ON FRAMING PLANS OR DETAILS DRILL A 3/4" DIAMETER HOLE MIN. 6" DEEP AT THE LOCATION OF THE OMITTED RISK CATEGORY II QN 3. FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD N REBAR, AND INSTALL VERTICAL REBAR (SIZE AS NOTED ON PLAN) INTO EPDXY BUILDING TYPE V B Co F- U- SHALL SHALL BE TREATED IN THE FIELD OITHED IN ACCORDANCE WITH AWPA M4.R STRUCTURE &ARE EXPOSED TO WEATHER FILLED HOLE EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQUIVALENT. ENCLOSURE CLASSIFICATION ENCLOSED � J Z O 4. THE PORTIONS OF GLUED-LAMTIMBERS THAT FORM THE STRUCTURAL FOLLOW MANUFACTURE'S INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS INTERNAL PRESSURE COEFFICIENT +/- 0,18 H SUPPORTS OF A BUILDING OR OTHEFROM DRILLING ARE REMOVED FROM HOLE BY USING COMPRESSED AIR PRIOR TO & NOT PROTECTED BY A ROOF, SAVE OR SIMILAR COVERING SHALL BE PRESSURE APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANUFACTURER'S EFFECTIVE WIND WIND PRESSURE AND SUCTION (PSF) TREATED w/ PRESERVATIVE, OR BE MANUFACTURED FROM NATURALLY DURABLE OR w SPECIFICATIONS, THEN FILL CELL IN THE NORMAL WAY DURING BONDBEAM POUR. W PRESERVATIVE-TREATED WOOD. U)USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR AREA (SQ FEET) (+) VALUE DENOTES PRESSURE � W 5. ALL LUMBER SPECFIED ON DRAWING ARE INTENDED FOR DRY USE ONLY (MOISTURE = CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING &FIRE SAFETY SYSTEMS ARE THE DIAMETERS(EXCLUDING BEND). (-) VALUE DENOTES SUCTION RESPONSIBILITY OF THE CONTRACTOR & TO BE DESIGNED AND DETAILED BY OTHERS. 2. STRAPS/CONNECTOR SUBSTITUTION_ MAY SUBSTITUTE STRAPS/CONNECTORS w/STRAPS/CONNECTORS OF EQUAL OR AREA 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER O4 �5 S GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION,+ 21.2 (+)21.2 OR THE STUD UP TO 1 DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL HOLES OVER PROVIDED ALL MANUFACTURES INSTALLATION INSTRUCTIONS ARE FOLLOWED. 10 ( ) ( 1" IN DIA FOR PLUMBING LINE'S, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD 3. STAIR CONSTRUCTION - 22.9 - 28.3 Fn SHOES, TYP U.N.O. 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS RIM BOARDS MAY 20 + 20.2 (+ 20.2 7. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE BE USED FOR RISERS & TREADS ILO 2x12'S - 22.0 -)26.4 TO STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE TYPE OF 4. METAL STUD SUBSTITUTION 50 +19.0 (+)19.0 - WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTOR THAT RESIST CORROSION. WOOD STUDS MAY BE SUBSTITUTED OF METAL STUDS IN NON -LOAD BEARING WALLS 20.8 (-)23.9 FOR EXAMPLE. ACQ-C, ACQ-D, CBA-A OR CA-B REQUIRE HOT-DIPPED GALVANIZED OR 5. OMITTED J-BOLT 100 �+�l 8.0 (+)18.0 STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES NOT. -1/2" ALL THREAD w/ WASHERS MAY BE USED ILO 1/2" J-BOLTS W/ WASHER - 19.8 -)22.0 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR MASONRY IS TO DRILL & EPDXY w/ SIMPSON SET EPDXY @ 5" MIN EMBED. GARAGE DOORSW BE PRESSURE TREATED. „ 9 -0 x 71-000 16 -0 x 7t-Oto � -1/2%6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE � 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. USED ILO 1 /2" J-BOLT. + 18.4 + 17.7 Z N SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS W/OUT WOODEN TOP PLATES. 6. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS - 20.9 - 19.7 cy 0 1- 10. SEE PLAN FOR STUD PACK & BEAM NAILING PATTERNS 7. MORTAR JOINTS ENGINEERED LUMBER NO VERT. � Z Z -FOR BED JOINTS 1 /2 TO 1 ,GROUT FILL CELLS IN BLOCK AFFECTED ( E v� O ALL ENG. LUMBER IS TO HAVE THE MIN. DESIGN VALUES BELOW: (/� Q COLUMNS BEAMS STUDS REINF. REQUIRED) WIND PRESSURE SUCTIONLij E = 1,800,000 Ib/in' U.N.O. E - 2,000,000 Ib in' U.N.O.E 1,500,000 Ib int U.N.O. )- FOR HEAD JOINTS GREATER THAN 3/4 , GROUT FILL CELL IN BLOCK AFFECTED ON DIAGRAM 5 5 co � / EITHER SIDE OF JOINT. PROVIDE 1 5 VERT. REINF. IN EACH CELL CONT. PER PLAN. LO Fb = 2500 IFb = 3000 Fb = 2200 ** EXCEPTION: IF TIE BEAM COURSE AND ADJACENT TWO COURSES BELOW, AS WELL AS 4 5 5 4 ,, O O O Ft = 1500 IFt = 1700 Ft = 1500 1st TWO COURSES FROM FOUNDATION HAVE HEAD JOINTS WHICH FALL WITHIN THE M N SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQUIRED TO BE m Fc II= 3000 Fc II= 3000 Fc �I= 2100 EPDXIED INTO TIE BEAM OR FOOTING tel✓' (~) 0 Z Fc 1 = 900 IFc 1 = 900 Fc 1, = 450 8. FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE WJ W W Fv = 285 IFv = 285 Fv = 150 (1) #5 VERT. REINF. IN EACH CELL, CONT. PER PLAN. STANDARD DESIGN PRESSURE NOTES -� �., o O WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN GING CMU WALL 0 Q O # 9. OVERRAN 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CL CONDITION U.N.O. -FOR CMU OVERHANGING FOUNDATION UP TO 1/2", NO FIX IS REQ'D POUR TIEBEAM AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA CL ~ ~ CEILING CONSTRUCTION 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24O.C. FRAMING U.N.O. VERTICAL CELLS PER PLAN. BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON 2. 5/8" TYPE"X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN -FOR CMU OVERHANGING FOUNDATION FROM OVER 1/2 TO 1-1/8", GROUT FILL THE LINEAR INTERPOLATION FOR THIS SITE. LIVING SPACE IS ABOVE THE GARAGE. FIRST THREE COURSES IN THE WALL ALONG AREA AFFECTED AS WELL AS TIE BEAM AND 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, DAFTNG:STRUCTURAL ENG: BED VERTICAL CELLS PER PLAN _ UNDER STAIR PROTECTION 2 STORY HOME IS 3OFT DRAFTING: 1. ENCLOSED ACCESSIBLE SPACE (UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE -FOR CMU OVERHANGING FOUNDATION FROM OVER 1-1/8", CONTACT ENGINEER OF 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE -srRucR: TNT RECORD FOR APPLICABLE REPAIRS. WIND PRESSURES. & ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE w/ 1 /2"(12.7MM) GYP. B.D. 4. "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR QC CHECK: CC BUILDING CORNERS. JOB No. TM - 2153194 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR - - - - -- SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER SCALE: AS INDICATED EFFECTIVE AREAS. DATE 10/11/2016 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND-BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. si REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS A n- n-' FOUNDATION PLAN 1/4"= 1 1-011 FOUNDATION NOTES: 1. PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6" AND SEALED. 2. PROVIDE 3-1/2" 3000PSI CONC. SLAB W/ 6x6xW1.4xWI.4 WELDED WIRE MESH PLACED AT MID DEPTH ON 6 MIL. VAPOR BARRIER ON COMPACTED FILL (FIBER MESH MAY BE USED ILO WWM, WHEN FIBER MESH. MEETS OR EXCEEDS SPECIFICATIONS SET FORTH IN CURRENT CODE EDITION. 3. VERT. #5 BAR TO BE HOOKED AT TOP & BOTTOM (FTG. & TIE BEAM ENDS) W/MIN. 12 BAR DIAMETER LEGS EXCLUDING BEND @ EA. END. LAP SPLICES SHALL BE NO LESS THAN 25". 4. CONSULT W/MAN. SPECIFICATIONS PRIOR TO POURING OR RECESSING DOOR SILLS. 5. EXTERIOR SLABS SHALL SLOPE 1/8" PER FOOT AWAY FROM HOUSE. 6. CONTROL JOINTS (IF SHOWN) ARE NOT REQUIRED BY CODE BUT ARE SUGGESTED (ESPECIALLY WHEN USING FIBER REINF. CONC.) CONTROL JOINTS TO BE SAW CUT A DEPTH OF 1/4' OF THE THICKNESS OF THE SLAB. FILL CUT W/APPROVED JOINT MATERIAL OR USE ALTERNATE APPROVED METHOD. 7. MECHANICAL EQUIP. LOCATIONS WILL BE DETERMINED BY COMMUNITY & COUNTY CODES. 8. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3" ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 9. NO WOOD STAKES PERMITTED IN FOUNDATION. 10. PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED DOWN. SEE SHEET SDI FOR ADDITIONAL INFORMATION. GC TO DETERMINE STEP LOCATIONS IF REQUIRED 11. SEE TYPICAL DETAIL ON LINTEL PLAN FOR REQUIRED STEEL BENDS AND LAP SPLICE. SEE DTL MF09 AND MF10 ON SDI FOR STANDARD FOOTING STEP DOWN AND CORNER INFORMATION. 12. ANY EQUIPMENT AND/OR APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED A MIN OF 18". CONTRACTOR TO PROVIDE SUCH PLATFORM w/ EITHER MASONRY OR WOOD CONSTRUCTION 13. ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF (SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS). IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY, THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. SOIL TO BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS, COMPACTED IN 12" LIFTS TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM - 1557 ( MODIFIED PROCTOR). THE FOUNDATION SIZES INDICATED ON THE FOUNDATION PLAN HAS BEEN DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY OF 2000 PSF. 14. PENDING SITE CONDITIONS, IF STEMWALL IS REQUIRED, G.C. TO DETERMINE REQUIRED COURSES FOR STEMWALL FOUNDATION. SEE STEMWALL CHART ON SDI FOR REQUIRED REINFORCEMENT AND FOOTING SIZES PENDING DEPTH OF STEMWALL FOOTING SCHEDULE O12"x12"x12" dp w/ #5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (2) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 2O24"x24"x12" dp w/ #5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (3) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 28"x28"x12" dp w/ #5's EQUALLY SPACED EA. 2.3 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 30"x30"x12" dp w/ #5's EQUALLY SPACED EA. 2.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 32"x32"x12" dp w/ #5's EQUALLY SPACED EA. 2.6 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. O36"x36"x12" dp w/ #5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 42"x42"x12" dp w/ #5's EQUALLY SPACED EA. 3.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (6) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 4O48"x48"x12" dp w/ #5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 54"x54"x16" dp w/#5's EQUALLY SPACED EA. 4.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (8) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. O60"x60"x16" dp w/#5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (9) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. SYMBOLS LEGEND ■ INDICATES GROUT FILLED CELL WITH (1) VERT. #5 CONT. FTG. TO TIE BEAM (8'-0" O.C. MAX U.N.O.). • INDICATES GROUT FILLED CELL WITH (2) VERT. #5 CONT. FTG. TO TIE BEAM. 123 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT. #5 CONT. FT.G TO TIE BEAM. co • r 'C • • •• �,® W 10 O ' _ C-3 Q o cc)�. Q0 =C) .. L.i Q D J.��• �` Z m LL 1 EV O Ole w of O bol c1r) 1 V U r,ph r i' 3j O II 6 O z U C O a • Q U 4 i i l iii i „4�1u I ll,ril I I Sl���j O < a am Z O LJ r` h_ 0 w Z ��1' o O Q Z - LL DI O itc Z U ~��'0D= L— H F- ? Z in f J�Zw fn o v _��� 95 Q Z Z¢ Z Z E 10 (-5 0 (6 N LL C) J Z O W NwZ La W 11 2W) Z N OF � OZO Ld � W)Y e � OLap gN� �— oCm U O J Z LL' J W W o ao= STRUCTURAL ENG: BED DRAFTING: -STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 S2 C9 N J C) r - LO zo %0 C? 0 20'-8" T-11" 10'-2" T-11" R 0 r O M 0 4) 0 M 8" 2'-9" 2'-11 2'-11 " 2'-9" 2'-8" 4'-8" 2'-4" 16'-0" 2'-4" 60 SYMBOLS LEGEND W F- ■ INDICATES GROUT FILLED CELL WITH (1) VERT. #5 CONT. FTG. Q TO TIE BEAM (8'-0" O.C. MAX U.N.O.). ® INDICATES GROUT FILLED CELL WITH (2) VERT. #5 CONT. FTG. TO TIE BEAM. El INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT. #5 CONT. FT.G TO TIE BEAM. Z O V (1) #5 @ TOP, BOTTOM .a� & MID -HEIGHT OF ❑ o W COLUMN cm0 0 ❑ a FILLED CELL ua (1) #5 @ TOP, BOTTOM & MID -HEIGHT OF COLUMN DOWEL LAYOUT PLAN_ PLAN VIEW SECTION VIEW 1 MASONRY COLUMN TIE IN _' W (1) CONT. #5 FROM TIE C.0 BEAM TO FOOTING MASONRY WALL �1r°� ` a`°°a�t`S ��%� p REINFORCING PER ?�li Q ;j : I-- = Z PLAN (TYP). = �• '� �� w += 2 0 0 a 0 w Q a ® Z 0 °assaaQ ♦♦ � � CD `/ O 1/2"= 1 '-0" rs, fpr ry, O 1tr m O z° U c O c� OII w I�i Niuliil Vllill �i�6� tiG�� (D L Z �� Y cn o O 0 � Q W a O W J h o C ZZ°)�� �x W w E W I"-' Z (n J � U Q Q C J Zo p 0o u� r1 w Z �n L.L J U) � Z w o 8 J U) a =2,Lu� U)0 F, w ui o Z Z¢`)zZ E W 0 o�20 Qm N W SU N¢ �J 0 00 �w W � o W u 2 Z N c5 0 A Z Z 0 O co W �Y 0 Ln gN� m U OJZ ) �a0 O Q0 STRUCTURAL ENG: BED DRAFTING: STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 S3 WALL LEGEND w _ Q = 8'-0 T.O.M. = 9'-4" T.O.M. D n rn rn rn rn rn rn 0) co a~o a~o a~o ti = 12'-0" T.O.M. = INTERIOR/EXTERIOR BEARING WALLS VERIFY HGT. W/ ARCHITECTURAL PLAN U.N.O. Z O C) 'U) � W 0 0 La CL 0018 LLi 00 o� � W y L' lJ J Z < U Z 0 00 u u O p, or�601 c1r) 1� U yI��3J o 1—I •r O z U � O 4 +� o V U coo9 o O ��ly am Z Z Q O w q O X0.1 � N W Z F- M ti E QZ LL W Z y J (n �Z�o Q OO u)v8 U) HFww o Z=1 (,)HzE 0 0 2 (L V— Q aNJ O �— IL) ZO U N 0 �w0 W W o W rr 2 Z N � ZO ra 0 Q J OC cY r a O ,� 0 �N� Lu 0 0 O QO= STRUCTURAL ENG: BED DRAFTING STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 ROOF FRAMING P SCALE: AS INDICATED DATE: 10/11/2016 1/4"=1'-0" NOTE. SEE PAGE S4.1 FOR NOTES AND CONNECTOR LEGEND S4 BEARING WOOD WALL SCHEDULE TAG STUD LUMBER CONNECTION & FASTENERS UPLIFT CAP. BLOCKING TOP BOTTOM O(3)2X6 SPACING SPECIES (plf) O(3)2X8 BW1 16" SPF (3)12d TOENAILS (3)12d TOENAILS NO UPLIFT MID -SPAN BW2 16" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW3 16" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf 3rd. PT. BW4 12" SPF (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW5 12" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW6 12" SPF 1/2" THREADED ROD @ 48" O.C. 1160If p PT. 7" EMBEDMENT 6x6: ABU66 w/(12)16d NAILS & 8" EPDXY ANCHOR w/MIN. 7" EMBEDMENT ADJUST AS REQ'D TO MISS STUDS MIN. 7" EMBEDMENT 3rd. BW7 16" SYP (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW8 16" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BWg 16" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf i 3rd. PT BW10 12" SYP (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW11 12" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW12 12" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf 1 3rd. PT. STANDARD BEARING WALL W/THREADED ROD NOTES 1. VERIFY w/PLAN FOR WALL SIZE. ASSUME 2x4 STUDS U.N.O. 2. ALL LUMBER TO BE EITHER SPF #2 OR SYP #2 U.N.O. (CAN BE SUBBED WITH OUT REVIEW) ALWAYS NAIL STUDS TO TOP AND BOTTOM PLATE W/ (3) 12d TOENAILS 3. IF BEARING WALL IS NOT CALLED OUT CONTACT E.O.R. 4. IF "BW" CALLED OUT ON 2nd FLR. SEE PLAN FOR STUD TO STUD CONNECTIONS. 5. ATTACH ALL STUDS TOP AND BOTTOM W/ (3) 12d TOENAILS. 6. MID OR 1/3 PT BLOCKING TO BE 2x W/ (2) 12d TOENIALS EACH END. 7. %2' THREADED ROD w/ MIN 6" EMBED (OR 6" PAST STEP DOWN) w/ SIMPSON SET EPDXY. SEE ABOVE FOR SPACING. CENTERED Win TOP PLATE. FOLLOW SIMPSON INSTRUCTIONS FOR INSTALLATION OF ROD AT BASE. NUT AND 2"x2"x1/4" WASHER @ TOP. THREADED ROD TO BE PLACED 6" AWAY FROM ANY STRUCTURAL COLUMN UNLESS PLANS INDICATE CONNECTIONS. 8. 2x P.T. PLATE AT BASE OF BRG.WALL W/ THREADED ROD. NO ADDIT'L BASE CONNECTIONS TO THE FOUNDATION ARE REQ'D IF B RG. WALL IS INDICATED WITH BW1, BW4, BW7, & BW10. THESE WALLS ARE ONLY SUPPORTING THE FLOOR LOAD AND DO NOT HAVE UPLIFT, THE STUDS ARE TOENAILED/ ENDNAILED TO THE PLATE AND THE 2X BASE PLATE CAN BE ATTACHED WITH HARD CASED GUN NAILS & THE ANCHOR BOLT ATTACHMENT INDICATED IN BEARING WALL SCHEDULE IS NOT REQ'D. 9. AT SHEAR WALL LOCATIONS ONLY: NUT & WASHER @ BASE OF THREADED ROD ARE REQ'D. SEE PLAN FOR ADDIT'L SHEARWALL INFO. AND DETAILS. 10. FOR BEARING WALL TO MASONRY CONNECTION SEE DETAIL MD03/SD2 U.N.O. ON PLAN. 11. AT HEADER LOCATIONS WITHIN BEARING WALLS SEE DETAIL WF09/SD3 U.N.O. ON PLAN. 12. COLUMNS Win BEARING WALLS w/ UPLIFT THAT DO NOT SHOW A BASE CONNECTION: CONTRACTOR TO INSTALL THREADED ROD Win 6" OF COL. (MIN CENTER TO CENTER SPACING OF THREADED ROD IS 8") 13. IF PLUMBING IS TO BE RUN THROUGH BEARING WALL, CONTACT EOR FOR FURTHER REVIEW. 14. AT NON-BEARING WALL LOCATIONS 2x4 SPF#2 STUDS @ 24"o.c. MAX. ARE ADEQUATE. AT NON-BEARING HEADERS USE (2)2x4 FLAT w/(3)12d TOENAILS EA. SIDE AND CRIPPLES AT 24"o.c. AT 2 -STORY OPEN AREAS INSTALL NON-BEARING WALL STUDS @16"o.c. A SINGLE BASE PLATE (P.T. IF AGAINST CONCRETE) AND SINGLE TOP PLATE ARE ADEQUATE LEAVE A -1" GAP FROM TRUSS TO TOP PLATE AND ATTACH USING EITHER (2)12d TOENAILS OR SIMPSON DTC CLIP. ATTACH BASE PLATE w/ EITHER GUN NAILS @32"o.c. OR (2)12d NAILS TO EACH FLOOR TRUSS. COLUMN SCHEDULE qO (2)2X4 SPF #2 BUILT UP STUD COLUMN O(3)2X4 SPF #2 BUILT UP STUD COLUMN O(4)2X4 SPF #2 BUILT UP STUD COLUMN <8>(2)2X6 SPF #2 BUILT UP STUD COLUMN O(3)2X6 SPF #2 BUILT UP STUD COLUMN O(2)2X8 SPF #2 BUILT UP STUD COLUMN O(3)2X8 SPF #2 BUILT UP STUD COLUMN O(3)2X4 SYP #2 BUILT UP STUD COLUMN O(2)2X6 SYP #2 BUILT UP STUD COLUMN O(2)2X8 SYP #2 BUILT UP STUD COLUMN OL 4x4 SYP #2 POST O6x6 SYP #2 POST <s>8x8 SYP #2 POST PO 3-1/2"x3-1/2" LVL COLUMN. QO 3-1/2"x5-1/4" LVL COLUMN. O3-1/2"x7" LVL COLUMN. O3-1/2"x9-1/2" LVL COLUMN. TO 5-1/4"x5-1/4" LVL COLUMN. O5-1/4"x7" LVL COLUMN. XO 7"x7" LVL COLUMN. O3 1/2" X 11 7/8" LVL COLUMN ZO 5 1/4" X 9 1/2' LVL COLUMN STANDARD COLUMN NOTES 1. NAIL ALL BUILT-UP STUDS PER DTL. WF08/SD4. 2. ALL (POST/ LVL COLUMNS IN EXTERIOR CONDITION SHOULD BE P.T. OR WOLMANIZED. 3. CONTRACTOR TO USE ABU BASE CONNECTORS @ SPF/SYP SOLID POSTS. AT EXTERIOR CONDITIONS 44: ABU44 w/(12)16d NAILS & g" EPDXY ANCHOR w/MIN. 7" EMBEDMENT 6x6: ABU66 w/(12)16d NAILS & 8" EPDXY ANCHOR w/MIN. 7" EMBEDMENT 8x8: ABU88 w/(18)16d NAILS & (2)8" EPDXY ANCHORS w/ MIN. 7" EMBEDMENT 4. POST/LVL INSTALLED WITHIN BRIG. WALL TO BE WITHIN TOP AND BASE PLATE U.N.O. ON PLANS. 5. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. NAIL SCHEDULE STANDARD NAIL GENERAL DIAMETER/ LENGTH 8d .131" x 22" 10d 148" x 3" .148" x 34" 12d 16d 162" x 32" 8d RING SHANK - - -- .113" x 28" NAILING NOTES 1. CONTRACTOR MAY USE A DIFFERENT NAIL THEN INDICATED AS LONG AS IT MEETS OR EXCEEDS THE DIAMETER AND LENGTH INDICATED. 2. CONNECTORS MAY USE DIFFERENT NAIL LENGTHS. MINIMUM NAIL LENGTH PER CONNECTOR IS REQ. IF LONGER NAIL IS USED IT IS ADEQUATE AS LONG AS IT DOES NOT EXTEND THRU THE MEMBER IT'S BEING ATTACHED TO. CONNECTOR SCHEDULE TAG BEAM SIZE CONNECTIONS VALUES VALUESSPF(lb) TAG SIMPSON CONNECTOR TYPE TO BEAM: SIMP. HUC48 w/(14)16d NAILS SYP(Ib) (2)2x8 #2 SYP META16 w/(7) 10dx12' NAILS OR B2x8 WITH 1/2" FLITCH w/(6)10d NAILS & (14)1'x24" 1 ❑ META20 w/(7) 10d x 12" NAILS FRAME TO CMU 1450 1450 ON MASONRY: SIMP. META16 (2)META16 OR (2)META20 2)2x12 #2 SYP w/2' FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 lfl (1)ply TRUSS (10)10d x 12' NAILS FRAME TO CMU (1)ply 1985 (1)ply 1985 B2x10 (2)ply TRUSS (12) 16d x 12" NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d (2)ply 1900 (2)ply 1900 NAILS & (18)4'x24' TAPCONS H10A w/(18)10d x 12" NAILS OR H10A 1015 H10A 1340 lfl (2)ply TRUSS H10A-2 w/(18) 10d x 12" NAILS FRAME TO FRAME H10A-2 1070 H10A-2 1245 H5.5x11.25 HTS20 w/(24)10d x 12" NAILS (10) 10d NAILS B2x12 WITH 1/2" FLITCH TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 1245 1450 PLATE BETWEEN PLIES (2)HTS20 w/(24)10d x 12" NAILS HEADER SUPPORT # JACKS/KINGS REQ'D. @ OPENING OPENING SIZE TO POST: SIMP. HTS20 OR LSTA18 El (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 2490 2900 6 H2.5A w/(10)8d FRAME TO FRAME 535 600 MTS 12 w/(14)10d x 12" NAILS ON MASONRY: SIMP. META16 (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 860 1000 El MGT w/(22)10d 8" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. FRAME TO CMU 3140 3140 (2)1.75"x11.875" LVL 7" EMBEDMENT NAILS & (18)1'x23' TAPCONS HTT4 w/(18)16d x 22" NAILS & 8" EPDXY ANCHOR w/SIMP. FRAME TO CMU 3640 4235 TO POST: SIMP. HTS20 OR LSTA18 SET EPDXY MIN. 7" EMBEDMENT TO BEAM: SIMP. HUC410 w/(18)16d & 10 HGT-2 w/(16)10d NAILS w/$" EPDXY ANCHOR w/SIMP. SET FRAME TO CMU 6280 6280 EPDXY MIN. 5" EMBEDMENT NAILS & (18)4'x23' TAPCONS 11 HTSM16 w/(8)10d NAILS & (4) 4"x 24" TAPCONS FRAME TO CMU 1020 1175 12 LSTA18 w/(14)10d NAILS HEADER TO STUDS 1110 1235 13 (2)LSTA18 w/(14)10d NAILS HEADER TO STUDS 2220 2470 14 LSTA18 w/(14)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 833plf 928plf 15 LSTA24 w/(18)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 1235 1235 16 MSTC28 w/(36)16d SINKERS CENTERED STUDS TO BEAM/GT 2980 3455 17 MSTC40 w/ (52) 16d SINKERS CENTERED STUDS TO BEAM/GT 4305 4745 NAIL ALL LVL BEAMS TOGETHER USING (3) ROWS OF 12d NAILS @ 6"o.c. (TYP. LTT206 w/(10) 10d NAILS & g" EPDXY ANCHOR w/SIMP. SET 2. VERIFY w/PLAN CORRECT LENGTH OF BEAM REQ'D. (MIN. 4" BRG. EA, END) 3. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS. 4. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT WRITTEN 18 EPDXY MIN. 7" EMBEDMENT MIN. T EMBED. -AT LVL/PL COLUMN TO FTG. OR 1290 1300 COLUMNS USE (18)#10x12" SD SCREWS INSTEAD OF NAILS CMU - HTT4 w/(18) 16d x 22" NAILS w/8' EPDXY ANCHOR w/SIMP. - 19 SET EPDXY MIN. 7" EMBED. -AT LVL/PL COLUMNS USE COLUMN TO FTG. 3640 4235 (1*)#10x12" SD SCREWS INSTEAD PF NAILS (3)HTS20 w/(24)10d x 12" NAILS 20 (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 3735 4350 21 MSTCM40 W/ (14) 16d SINKERS AND (10) 1/4"x2-1/4" TITENS FRAME TO CMU 2420 2800 22 SIMPSON HGUS 5.50/10 W/ (63) 16d NAILS GIRDER TO COL./ BEAM 9100 4095 HUC210-2 HEADER TO CMU w/ (18) 1/4"x2-3/4" SIMPSON GRAVITY:5085 GRAVITY:5085 23 TITENS & (10) 10d NAILS FRAME TO CMU UPLIFT:1810 UPLIFT:1810 24 HUS26 TO LEDGER W/(14)16d NAILS AND TO TRUSS FRAME TO FRAME 1335 1550 W/(6)16d NAILS 25 HUSC210-2 W/(8)16d NAILS TO BEAM AND (8)16d NAILS TO FRAME TO FRAME GRAVITY:2125 GRAVITY:2125 COLUMN UPLIFT:3290 UPLIFT:3290 2B LTT20B w/(10) 10d NAILS & a' EPDXY ANCHOR w/SIMP. SET FRAME TO CMU 1290 1300 EPDXY MIN. 7" EMBED. STANDARD CONNECTOR NOTES 1. ALL TRUSS/BEAM TO MASONRY CONNECTIONS TO BE SIMP. META16, U.N.O. ON PLAN AT FLOOR TRUSSES PARALLEL TO MASONRY WALLS CONNECT w/SIMP. META16 @ 24"o.c. OR 32"o.c. VERIFY w/ TRUSS SHOP DRAWINGS FOR VERTICAL SPACING WITHIN FLOOR TRUSS. (IF SITTING ON FRAME WALL USE SIMP. LSTA18(14) @ 24"o.c. OR 32"o.c.) CONNECT ALL CONTINUOUS RIM BOARDS TO TOP OF MASONRY W/SIMP. META16, @ 32"o.c. MAX. AND (2) AT EACH CORNER. 2. ALL TRUSS/BEAM TO FRAME CONNECTIONS TO BE SIMP. H10A FOR SINGLE PLY, OR H10A-2 FOR 2 -PLY U.N.O. ON PLAN 3. CONNECT ALL TYPICAL HIP JACKS (CORNER JACKS) TO FRAME USING SIMP. H2.5A CONNECTOR. IF UPLIFT EXCEEDS 535lbs USE (2) H2.5A CONNECTORS. 4. CONNECT ALL INTERIOR FLOOR TRUSSES/JOISTS TO INTERIOR BRG. WALLS USING (3)12d TOENAILS. 5. ALL TRUSS TO TRUSS CONNECTIONS TO BE SPECIFIED BY TRUSS MANUFACTURER, U.N.O. ON PLAN. 6. MISSED LINTEL STRAPS: CONTRACTOR TO INSTALL SIMP. HTSM16 @ EACH MISSED META16 STRAP LOCATION. IF DOUBLE META16 @ A 2 -PLY OR 1 -PLY TRUSS IS MISSED, USE (2)HTSM16 STRAPS. IF UPLIFT IS HIGHER THEN 2100lbs, CONTACT E.O.R. FOR FURTHER REVIEW. STANDARD HEADER NOTES 1. VERIFY w/PLAN FOR CORRECT LENGTH OF HEADER REQ'D. SIZE INDICATED ON PLAN IS MINIMUM REQ'D. PER LOCATION. LARGER HEADER MAY BE INSTALLED WOUT APPROVAL FROM E.O.R. 2. ALL HEADER JACKS/KINGS TO MATCH WALL LUMBER GRADE U.N.O. ON PLAN, ATTACH STUDS TOGETHER FOLLOWING DTL. WF08/SD4. 3. NAIL HEADER PLIES (INCLUDING LVLs) TOGETHER USING (2) ROWS OF 10d NAILS @ 12"o.c. ONE SIDE. MIN. 2" FROM TOP AND BOTTOM. USE (3) ROWS IF HEADER IS 2x10 OR LARGER. TOP -LOADED HEADERS ONLY. CONTACT E.O.R. IF MEMBERS BUCKET INTO HEADER 4. NAIL KING STUDS TO HEADER w/(3) 10d TOENAILS PER SIDE IN ADDITION TO NAILING PER HEADER SCHEDULE. 5. IF MORE THEN (1)KING IS REQ'D. AS PER HEADER SUPPORT TABLE, GC TO INSTALL REQ'D. NAILS FROM 1st KING INTO HEADER THEN ATTACH ADDIT'L KING PER DTL. WF08/SD4. OTHERWISE, CONTACT E.O.R. FOR REQ'D. WOOD SCREWS. 6. IF HEADER IS NOT SPECIFIED CONTACT E.O.R. 7. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. 8. SEE DTL. WF09/SD3 FOR 1ST FLOOR HEADER CONSTRUCTION AND CONNECTIONS AT 2 STORY CONDITIONS. SEE 2ND FLOOR NOTES FOR MORE INFO. BEAM SCHEDULE TAG BEAM SIZE CONNECTIONS H2x6 (2)2x6 #2 SYP w/2' FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 Y DATE: TO BEAM: SIMP. HUC48 w/(14)16d NAILS H2x8 (2)2x8 #2 SYP TO MASONRY: SIMP. HU48 OR HUC48 B2x8 WITH 1/2" FLITCH w/(6)10d NAILS & (14)1'x24" H2x10 PLATE TAPCONS m U- ON MASONRY: SIMP. META16 H2x12 2)2x12 #2 SYP w/2' FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & H3.5x5.5 (2)2x10 #2 SYP (10) 10d NAILS B2x10 WITH 1/2" FLITCH TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d H3.5x7.25 PLATE NAILS & (18)4'x24' TAPCONS ON MASONRY: SIMP. META16 H3.5x9.25 (2)1.75"x9.25" LVL TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & H5.5x11.25 (2)2x12 #2 SYP (10) 10d NAILS B2x12 WITH 1/2" FLITCH TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d H3x12 PLATE NAILS & (18)4"x24" TAPCONS PLATE BETWEEN PLIES ON MASONRY: SIMP. META16 HEADER SUPPORT # JACKS/KINGS REQ'D. @ OPENING OPENING SIZE TO POST: SIMP. HTS20 OR LSTA18 JACKS @ EA. END KINGS @ EA. END TO BEAM: SIMP. HUC410 w/(18)16d & 1 1 (10) 10d NAILS B3.5x11.25 (2)1.75"x11.25" LVL TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4'x24" TAPCONS ON MASONRY: SIMP. META16 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS 63.5x11.875 (2)1.75"x11.875" LVL TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)1'x23' TAPCONS ON MASONRY: SIMP. META16 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS B3.5x16 (2) 1.75"x16" LVL TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4'x23' TAPCONS ON MASONRY: SIMP. META16 TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. META16 65.25x16 (3) 1.75"x16" LVL * NAIL TOGETHER USING (3) ROWS OF 12d NAILS @ 6" O.C. EACH SIDE TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. META16 B3.5x20 (2) 1.75"x20" LVL * U.N.O. NAIL TOGETHER USING (3) ROWS OF 12d NAILS @ 6" O.C. EACH SIDE STANDARD BEAM NOTES 1. NAIL ALL (2) 2x BEAMS TOGETHER USING (2) ROWS OF 12d NAILS @ 12"o.c. (TYP. ONE SIDE) USE 3 ROWS WHEN 2x10 OR LARGER. MIN. 2" FROM TOP AND BOTTOM OF BEAM NAIL ALL LVL BEAMS TOGETHER USING (3) ROWS OF 12d NAILS @ 6"o.c. (TYP. ONE SIDE) MIN. 2" FROM TOP AND BOTTOM OF BEAM 2. VERIFY w/PLAN CORRECT LENGTH OF BEAM REQ'D. (MIN. 4" BRG. EA, END) 3. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS. 4. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT WRITTEN APPROVAL FROM THE E.O.R. 5. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS HEADER SCHEDULE TAG HEADER FASTENERS H2x6 (2)2x6 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(6) Y DATE: 16d NAILS H2x8 (2)2x8 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(8) Z Q ❑ 16d NAILS H2x10 2)2x10 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(10) m U- 16d NAILS H2x12 2)2x12 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(10) 16d NAILS H3.5x5.5 (2)1.75"x5.5" LVL ATTACH KING STUD TO HEADER w/(6) 16d NAILS H3.5x7.25 (2)1.75"x7.25" LVL ATTACH KING STUD TO HEADER w/(8) 16d NAILS H3.5x9.25 (2)1.75"x9.25" LVL ATTACH KING STUD TO HEADER w/(10) 16d NAILS H5.5x11.25 (3)1.75"x11.25" LVL ATTACH KING STUD TO HEADER w/(12) 16d NAILS H3x12 (3) 2x12 #2 SYP w/ 2" FLITCH ATTACH KING STUD TO HEADER w/(10) PLATE BETWEEN PLIES 16d NAILS HEADER SUPPORT # JACKS/KINGS REQ'D. @ OPENING OPENING SIZE SEE PLAN FOR WALL WIDTH JACKS @ EA. END KINGS @ EA. END V-0" TO 3'-11" 1 1 4'-0" TO 8'4" 2 2 ROOF NOTES: 1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. 2. TOP PLATE HEIGHTS VARY. SEE BUILDING SECTIONS, WALL SECTIONS AND ELEVATIONS FOR BEARING HEIGHTS. 3. TRUSS SPACING SHALL BE 24" O.C. MAX. UNLESS OTHERWISE NOTED. CONVENTIONAL FRAMING SHALL BE 16" O.C. MAX. OR AS OTHERWISE NOTED. 4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON-BEARING WALLS AND AT VOLUME AREA UNLESS NOTED OTHERWISE. STUDS CAN BE 24" O.C. W/ SINGLE TOP AND P.T. BASE PLATE LEAVE 1 1/2" GAP FROM TOP PLATE TO TRUSS BOTTOM CHORD. CONNECT TRUSS TO NON-BEARING WALL w/ SIMPSON DTC OR (2) 12d TOENAILS. 5. ALIGN TRUSSES AND HAND FRAMING SO ALL GYPSUM WALL BOARD WILL BE CONTINUOUS FROM FLOOR TO CEILING. 6. TRUSS MANUFACTURER TO INSURE DESIGN CONSIDERATION TO THE FOLLOWING ADDITIONAL LOADS: A) ALL CEILING HUNG SOFFITS AND SOFFITS WITH CABINETS AS SHOWN ON PLANS. B) ATTIC LOCATED MVAC UNITS AS SHOWN ON PLANS. 7. REFER TO MANUFACTURER SPECIFICATIONS FOR INSTALLATION REQUIREMENTS OF ALL HARDWARE BEFORE INSTALLATION. 8. GC REQ'D TO PROVIDE PERMANENT BRACING/ BLOCKING PER BCSI 1 (CURRENT EDITION). SEE COVER SHEET NOTES FOR MORE INFO & STANDARD DETAILS IN THIS DRAWING SET FOR ADDITIONAL BRACING/ BLOCKING INFO. 9. ALL TRUSS -TO -TRUSS CONNECTORS ARE TO BE PROVIDED BY TRUSS SUPPLIER. THIS INCLUDES BUT IS NOT LIMITED TO PIGGY BACK TRUSSES AND VALLEY TRUSSES 10. USE 5/8" TYPE X GYPSUM BOARD ON CEILING IN GARAGE WHEN LIVING SPACE IS ABOVE THE GARAGE. 11. IF ROOF TRUSS LAYOUT DEPICTS TRUSS LABELS OR ID'S, THIS LAYOUT HAS BEEN PROVIDED BY A TRUSS COMPANY TO USE FOR THE DESIGN OF THIS PROJECT. OTHERWISE AN ENGINEERED LAYOUT HAS BEEN DETERMINED BUT PRIOR TO CONSTRUCTION OR TRUSS FABRICATION, FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWS ARE TO BE SUBMITTED TO ENGINEER OF RECORD (E.O.R.) FOR REVIEW AND APPROVAL. AT THIS TIME THE E.O.R. RESERVES THE RIGHT TO REVISE THE PLAN AS REQUIRED PER THE REVIEW OF THE FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWS, ADDITIONAL FEE'S MAY APPLY. STARTING CONSTRUCTION OR TRUSS FABRICATION PRIOR TO THIS REVIEW IS NOT ADVISED, AND THE E.O.R. IS NOT RESPONSIBLE FOR ADDITIONAL COSTS DUE TO REVISIONS OF THE PLAN. IF CONVENTIONAL FRAMING IS SHOWN, NO TRUSS APPROVAL IS REQUIRED, UNLESS LAYOUT IS REVISED W/OUT WRITTEN APPROVAL FROM MCD. 12. IF DESIGN DOCUMENTS INDICATE THAT AN A/C UNIT IS TO BE RECESSED INTO THE ROOF SYSTEM, THE TRUSS SUPPLIER IS TO COORDINATE WITH THE DESIGNER AND BUILDER TO DETERMINE THE REQUIRED SIZE. (2) 751b MIN POINT LOAD SHOULD BE ADDED TO EITHER THE TOP OF BOTTOM CHORD OF THE TRUSS IN THE AFFECTED AREAS. THIS LOAD SHOULD BE INDICATED ON THE TRUSS SHOP DRAWINGS. CONNECTIONS OF THE A/C UNIT TO THE TRUSSES SHOULD BE SUPPLIED BY EITHER THE CONTRACTOR OR A/C SUPPLIER. SEE TB01/SD2 FOR MORE INFORMATION. BUILDER NOTE: IF THE TRUSS LAYOUT SHOWN DOES NOT MATCH THE TRUSS MANUFACTURERS LAYOUT ----STOP---- AND CALL THE ENGINEER OF RECORD PRIOR TO PLACEMENT OF ANY TRUSSES NAILING SCHEDULE: ROOFS: ROOF SHEATHING TO BE 15/32" OSB (WITH SHINGLE), 5/8" OR 19/32" OSB (WITH TILE) FASTENING WITHIN 4'-0" OF EAVES TO BE 4" O.C. AT ALL SUPPORTED EDGES AND 6" O.C. IN FIELD. FOR ALL OTHER AREAS NAIL @ 6" O.C. AT ALL SUPPORTED EDGES AND 6" O.C. IN FIELD. SHEATHING TO BE PLACED WITH LONG DIMENSION PERPENDICULAR TO SUPPORTS (TRUSSES). PROVIDE PLY CLIPS AT ALL UNSUPPORTED ROOF SHEATHING JOINTS EXCEPT AT PITCH CHANGE LOCATIONS. PLY CLIPS TO BE SPACED NO MORE THAN 24" O.C. GABLE ENDS: ALL SHEATHING TO BE MIN. 15/32" O.S.B. AND SHALL BE NAILED (1) ROW @ 3" O.C. AT TOP PLATE AND (1) ROW AT BOTTOM PLATE OF WALL, 6 O.C. ALL OTHER EDGES AND 6" IN FIELD. BLOCKING SHALL BE PLACED AT ALL SHEATHING JOINTS. EXTERIOR WALLS: SEE WF10/SD4 FOR MORE INFO. NAILS: NAILS USED IN ROOF SHEATHING APPLICATIONS SHALL BE 8d RING SHANK NAILS. ALL OTHER SHEATHING APPLICATIONS SHALL BE 8d, 8d RING OR SPIRAL SHANK, HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENT TO HAND DRIVEN NAILS. FASTENERS FOR PRESERV- ATIVELY TREATED WOOD SHALL BE HO,T-DIPPED ZINC -COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS SHALL BE IN ACCORDANCE WITH ASTM A 153. APA SHEATHING NOTE: 24/16 SPAN RATED SHEATHING REQUIRES BLOCKING AT ALL UNSUPPORTED PANEL EDGES AT HIP LOCATIONS. BLOCKING TO BE 2X4 ATTACHED AT EACH END WITH (3) 10d TOENAILS. FLOOR FRAMING NOTES GENERAL NOTES 1. FLOOR JOIST/TRUSS HANGERS SUPPLIED & ENGINEERED BY FLOOR JOIST/TRUSS CO. 2. REFER TO TRUSS MANU. DRAWINGS FOR TRUSS DESIGNATIONS. 3. GENERAL FLOORING FINISHES ARE ACCEPTABLE. IF LIGHTWEIGHT CONCRETE OR SELF LEVELING CONCRETE IS REQ. CONTACT E.O.R. ALONG WITH TRUSS CO. TO VERIFY FLOOR TRUSS DESIGN. NAILING SCHEDULE FLOOR SHEATHING TO BE 4" PLYWOOD OR OSB (U.N.0), WITH LONG DIMENSION PERPENDICULAR TO SUPPORT (FLOOR TRUSSES). NAILS: NAILS USED IN ALL FLOORING APPLICATIONS SHALL BE 8d, 8d FING OR SPIRAL SHANK, HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENT TO HAND DRIVEN NAILS, SPACING SHALL BE 6" ON EDGES AND 12" IN FIELD. Kin-rCC 1. FLOOR JOIST/ TRUSS MANUFACTURER SHALL COORDINATE LOCATIONS OF ALL MECHANICAL CHASES AND PLUMBING TO AVOID CONFLICT. 2. ALL JOIST TO JOIST OR TRUSS TO TRUSS CONNECTIONS SHALL BE SPECIFIED BY THE MANUFACTURER. 3. G.C./BUILDER SEE ARCHITECTURAL DRAWINGS FOR ROUGH OPENING LOCATIONS AND ADDITIONAL INFORMATION REQ. IFOR DOOR AND WINDOW INSTALLATION ALONG WITH DIMENSTIONS NOT SHOWN HERE. NOTES & CONNECTOR LEGEND Lu 0 O U 0 �,wtuedreroor o ''/�� CV u -i rL 0) V �' .••oe.eeei%/��� ��� LLI oc) Jj* 16 Y DATE: 4c Q �J ZV 4 0:W Q r .• v• Q� e •♦ . • .y: caeca® f�♦` Z Q ❑ 4 ®a f• es•eN%®® `V ®®rereil�e��e�. m U- O o U a W Z0 Z Z Ow v0 Lu 11 °6 J WU) LLJ ��-O L rz U) A ZN cs O a ZZ O O V) Y0 o� Y OLhp � C4 U OJZ N")�clO o QO= (D (/) U ti W J J ~ m � W 0 Lu Z H M r' o V Q U) Z u-� v m Z U ��ui�w J U) Zo 0 (Aw ui Z Z ¢U)zZ E O O�0a U �C� Q 0' N _I AVN¢ Z 0 2 STRUCTURAL. ENG: BED DRAFTING. -STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 S4.1 CONTRACTOR TO VERIFY AT CORNERS PRECAST "U" METAL LATH OR WIRE SCREEN THE GROUT IS LEVEL PROVIDE LINTEL W/ 3000 OVER COURSES NOT REQ'D WITH TOP OF BLOCK FOR STANDARD #5 psi CONC. PER TO BE FILLED. (SHEET METAL PROPER TRUSS/ FLOOR HOOK BAR. LAP LINTEL PLAN. IF & PAPER FELT PROHIBITED) SYSTEM BEARING (MIN 3") OTHER BARS INTO REBAR IS -- z a Lu a H O w z O Q CORNER AS REQ'D INDICATED IN LINTEL, #5 TO BE..HOOK PER HOOKED INTO MD08 SIDE VERTICALS 4 d. ° °° ° .d ..1 4° d .o. ..,. .1. d n ' ° ° ° �-4 .. a ._.n. d _. - �. ° a 4. ° O d ° � LL Q .y 4 4 °° ° °d a d ° '� Q d a e f d .� ---- --- 4I° Z w .4. ZBOTTOM STEEL IN LINTEL IF 07 INDICATE - SHOULD HOOK INTO -- -- ----- - - - VERTICAL CELLS PER MD08 , II : Q r�- ° d 4' ROUGH OPENING PER PLAN �. ° — 4 TYPICAL TRUSS ANCHOR PER PLAN PROVIDE SCREEN WHEN BLOCK BELOW IS NOT REQUIRED TO BE FILLED STANDARD 90 DEGREE HOOK TYP. BOND BEAM 8" x 8" x 16" K.O. LINTEL BLOCK FILL w/ 3000 psi CONC. w/ (1) #5 DIA. REBAR Al ° d STD. 90 DEGREE ANGLE 3000 psi I le CONC. w/ (1) #5 DIA. REBAR 8" x 8" x 16" CMU U.N.O. a a INDICATES FILLED CELL FROM FTG. TO TIE BEAM w/ (1) #5 BAR W/ 3000 psi CONC. SEE a . . MD08 FOR LAP INFO. PROVIDE CLEAN OUT OPENING @ GROUT d NO -SHEAR WALL T OPENING TYPICAL SHEAR WALL SEGMENT FILLED CELL AND REBAR (TYP). MORTAR —W4 JOINTS SHOULD NOT BE CUT 14 4 a'' SEE FOUNDATION FOR FOOTING a I ' TYPICAL MASONRY CONSTRUCTION SCALE: 3/4" = 1'-0" e GRADE 40 GRADE 60 ° BEND 0 LENGTH ------------------------ BEND 0 LENGTH LAP SPLICE d4I "A" /7-x/8 "B" 11 V, y7 "DII IIAII "BII 1111 "DII #3 1 41/4 15 LINTEL PER PLAN 4 1 /4 91/4 TYPICAL MASONRY CONSTRUCTION SCALE: 3/4" = 1'-0" LINTEL W/ TRANSOM DETAIL SCALE: 3/4" = 1'-0" REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) SEE PLAN FOR TOP OF WALL AND LINTEL INFO GRADE 40 GRADE 60 BAR SIZE BEND 0 LENGTH ------------------------ BEND 0 LENGTH LAP SPLICE 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 "A" /7-x/8 "B" 11 V, y7 "DII IIAII "BII 1111 "DII #3 1 41/4 15 LINTEL PER PLAN 4 1 /4 91/4 18 #4 21/2 5 5/8 91/2 20 3 5 5/8 121/2 24 #5 31/8 _....... _ _ ......... ................._._ TRANSOM OPENING 11 3/4 25 3 3/4 7 151/2 30 FRAME INFILL AROUND. 3 3/4 8 1/16 14 30 4 1/2 8 1/16 ' : " WINDOW BY BUILDER #7 `{' 9 13/16 16 1/2 SEE DOWEL PLAN FOR 5 1/4 9 13/16 21 3/4 SEE WF01/SD1 FOR / FILLED CELL INFO. MIN. (1) IS REQ'D ON MORE INFO EITHER SIDE U.N.O. (2) 2X8 SYP#2 P.T. HEADER —TURNED SIDEWAYS. ATTACH TO MASONRY -Y .; WALL W/ SIMPSON HU28-2 DOOR OR WINDOW OPENING HANGER @ EA. END. W/ MAX. OPENING 4 FT (14) 1/4" x 2-3/4" TAPCONS ` TO MASONRY & (6) 1Od NAILS TO HEADER LINTEL W/ TRANSOM DETAIL SCALE: 3/4" = 1'-0" REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) PRECAST LINTEL LOAD TABLE LOADS LISTED BELOW HAVE BEEN CALCULATED OR COMPILED FROM DATA FROM THE FOLLOWING APPROVED MAN. CAST -CRETE, QUALITY PRECAST CO., AND LOTT'S CONCRETE GRADE 40 GRADE 60 BAR SIZE BEND 0 LENGTH LAP SPLICE BEND 0 LENGTH LAP SPLICE 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 "A" /7-x/8 "B" 11 V, y7 "DII IIAII "BII 1111 "DII #3 1 41/4 15 21/4 4 1 /4 91/4 18 #4 21/2 5 5/8 91/2 20 3 5 5/8 121/2 24 #5 31/8 7 11 3/4 25 3 3/4 7 151/2 30 #6 3 3/4 8 1/16 14 30 4 1/2 8 1/16 18 1/2 36 #7 4 3/8 9 13/16 16 1/2 35 5 1/4 9 13/16 21 3/4 42 L 14D08 REBAR SPLICE DETAIL SCALE: 3/4" = 1'-0" STANDARD 90° HOOK U STANDARD 180° HOOK #3=2Y2" #4=2Y2" #5=2Y2" #6 = 3" #7=3Y2" r LO U 2 Q 13� PRECAST LINTEL LOAD TABLE LOADS LISTED BELOW HAVE BEEN CALCULATED OR COMPILED FROM DATA FROM THE FOLLOWING APPROVED MAN. CAST -CRETE, QUALITY PRECAST CO., AND LOTT'S CONCRETE GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE -CRETE, QUALITY, AND LOTTS STANDARD LINTEL NOTES STANDARD LINTELS CLEAR OPENING 8" UNFILLED 8F8-1 B / 8F8 -OB 8F16-1 B / 8F16 -OB 8F24-1 B / 8F24 -OB 8F32-1 B / 8F32 -OB 1. AREAS OF BLOCK ABV. MASONRY OPENINGS ARE TO BE GROUTED SOLID TO TIE BEAM. 2. (1) #5 REBAR IN TIE BEAM IS TO BE CONT. THRUOUT INCLUDING ABV. MASONRY OPENINGS. U.N.O. 3. ALL STANDARD LINTELS TO HAVE MIN. 4" BEARING EA. END. ALL RECESSED LINTELS TO HAVE MIN. 8" BEARING EA. END 4, LINTEL MIN. DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF DEEPER LINTEL INSTALLED THAN INDICATED ON PLAN, THE STRENGTH OF THE LINTEL INCREASES AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT EOR FOR APPROVAL. 5. (") ANY LINTEL DEEPER THAN 32" HAS BEEN VERIFIED TO WORK AS A MIN. 32" FOR THE LOAD CONDITIONS. ANY LINTEL GREATER THAN 32" HAS A GREATER CAPACITY AND THEREFORE IS ADEQUATE FOR THE LOADS. 6. G.C. TO VERIFY ALL LINTEL DIMS IN FIELD WITH WINDOW R.O. SPECIFICATIONS ON PLAN. DIMS SHOWN ON LINTEL PLAN ARE CLEAR SPAN AND USED TO VERIFY DESIGN OF LINTEL ONLY. VERIFY WITH WINDOW/DOOR SUPPLIER SPECIFICATIONS AND COORDINATE WITH EOR AS REQ'D. 7 LINTELS SHOULD BE SHORED UP DURING CONSTRUCTION AS REQUIRED PER THE LINTEL SUPPLIER SPECS. MCD IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS 11-611 2231 3069/3069 6113/6113 8974/8974 10000 / 10000 2'-2" 1783 3069/3069 6113/5163 8974/8054 10000 / 10000 2'-8" 1343 2693/2561 6113/3820 8974/5961 10000/8107 3'-2" 1217 2165/1969 6113/2931 8672/4576 10000/6224 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 4'-0" 860 1651 /1349 5365/1999 7342/3123 10000/4249 4'-6" 710 1423/1105 4360/1631 6036/2549 8328/3470 5'-2" 570 1232/1232 3480/2580 8360/3586 8825/4592 6'-2" 488 991/991 2661/2143 5681 /2698 6472/3685 7'-0" 416 752/699 1843/1625 3486/2602 6390/3302 8'-0" 354 726/699 1843/1625 3486/2255 6205/2885 9'-2" 315 618/535 1533/1247 2781 /1946 4754/2489 _ 10'-0" 292 567/454 1366/1277 2423/1770 4006/2263 _ 10'-8" 277 492/352 1254/1132 2193/1567 3552/2003 11'-2" 255 471 /352 1075/1075 1838/1567 2883/2003 12'-0" 239 418/297 1075/1045 1838/1446 2883/1848 12'-8" 0 369/261 1002/984 1697/1361 2630/1738 13'-4" 0 328/0 1234/0 1779/0 2662/0 14'-0" 0 292/0 1160/0 1660/0 2439/0 16'-0" 0 284/0 950/0 1379/0 1997/0 MATERIALS 18'-0" 0 211/0 750/0 1177/0 1676/0 18'-8" 0 142/0 598/0 1114/0 1468/0 1. fc PRECAST LINTELS = 3500 PSI. 2, f PRESTRESSED LINTELS = 6000 psi. 3. GROUTED PER ASTM C476 f'g = 3000 psi W/ MAXIMUM 3/8" AGGREGATE AND 8" TO 11" SLUMP. 4. CONCRETE MASONRY UNITS (CMU) PER ASTM C90 W/ MINIMUM NET AREA COMPRESSIVE STRENGTH = 1900 PSI. 5. REBAR PER ASTM A615 GRADE 60. PRESTRESSING STRAND PER ASTM A416 GRADE 6. 270 LOW RELAXATION. 7/32 WIRE PER ASTM A510. 20'-0" 0 180/0 598/0 1024/0 1441/0 20'-8" 0 145/0 550/0 981 /0 1376/0 0 110 / 0 450 / 0 824/0 1147 / 0 RECESSED LINTELS -FILLED CLEAR OPENING 8R6-1 B/8R6-OB 8R14-1 B/8R14-OB 8R22-1 B/8R22-OB 2'-4" 1694/1694 3725/3280 5499/5421 2'-8" 1425/1425 3343/3280 4933/4933 T-0" 1230/1230 2769/2769 4085/4085 LINTEL DESIGNATION SCHEDULE T-4" 1081/920 2769/1716 4085/2839 4'-4" 846/833 2121/1716 3127/2839 MARK LINTEL REQUIREMENTS F = FILLED WITH GROUT / U = UNFILLED R = RECESSED QUANTITY OF #5 REBAR @ 8F16-1 B/1T BOTTOM OF LINTEL CAVITY 5'-4" 664/572 1761/1761 2595/2595 6'-4" 526/434 1539/1539 1329/2267 T-4" 480/322 1334/1334 1964/1552 O 8RF6-1 B/1T 8'-4" 415/235 1152/1152 1694/1552 8F8-1B/1T LO U 2 Q 13� 1) FOR HEADER DEPTHS DEEPER THAN 32", USE VALUES FOR 32" DEEP HEADER QUANTITY OF #5 REBAR AT TOP 4 2) FOR HEADER DEPTHS NOT LISTED ON CHART, USE THE VALUES FOR THE NEXT DEPTH DOWN. O 8RF14-1B/1T NOMINAL HEIGHT � l ; NOMINAL WIDTH l 0 20'-8" 9'-6" 8 F 16-16/ 1 T cn TYPE DESIGNATION OD DO. . .. . ...... . caLO 10 <01: �0 0 .V.IVI. .v.IVI. 9'-4" 8'-0" O M OF M LINTEL PLAN 1/8"= 1 "-0" O 8RF14-OB/1T � 4.0 OI•t� � N F 8F16-OB/1T 1-1/2" CLEAR � U O 8F20-1B/1T Q � EA�Z_#5 REBAR AT TOP MIN. (1) REQ'Dao08F20-OB/1 T �zC.M.U. Z8RF22-16/1T � GROUT � z #5 REBAR AT BOTTOM OF LINTEL � V Z O 8F24-1B/1T � � CAVITY cp O 8RF22-OB/1T �* BOTTOM REINFORCING PROVIDED c o� 7-5/8 ACTUAL IN LINTEL (VARIES) O8" NOMINAL WIDTH 8F24-OB/1 T 0" 8RF30-1B/1T FILLED P G� O 8F32 -16/1T 1-1/2" CLEAR a 0 8RF30-OB/1T � 0 � z ° #5 REBAR AT TOP MIN. (1) REQ'D � Z O 8F32 -OB/1T v � C7 Q z C.M.U. G7 v 0 8F38 -1B/1T � g o W �� g �O z � LIJ ZI—Mr' 11 E 0 8F12-1B/1T �� � O� z� u� O 8F40 -OB/1T BOTTOM REINFORCING PROVIDED � J Z o � o � 0,00 3 7-5/8" ACTUAL IN LINTEL (VARIES) � ^ � � � w O 8F8 -OB/1T 8" NOMINAL WIDTH j Q 0 o N UNFILLED 15 � —Lu LO 0 Ln 0 S5 j � ° ~ � w �' OZ Z =cn~z E SAFE LOAD TABLE NOTES Q N wN¢ 1. ALL VALUES BASED ON MINIMUM 4" NOMINAL BEARING. EXCEPTION: SAFE LOADS FOR UNFILLED � � 7 Z � U LINTELS MUST BE REDUCED BY 20% IF BEARING LENGTH IS LESS THAN 6-1/2". SAFE LOADS FOR ALL O RECESSED LINTELS BASED ON 4" NOMINAL BEARING. � � � 2. 0 =NOT RATED. ®A 3. SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOAD ON THE SECTION SPECIFIED. W W 4. SAFE LOADS BASED ON GRADE 40, GRADE 60 MAY BE USED WITHOUT WRITTEN APPROVAL FROM EOR = 5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE DESIGNER BY PROVIDING � � ADDIONAL REINFORCED MASONRY ABOVE THE PRECAST LINTEL. S 6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" LINTELS ONLY. 7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING MOMENT AND SHEAR AT D -AWAY FROM THE FACE OF SUPPORT. 8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE LOAD FROM NEXT LOWER HGT. 9. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. � W 11 Z N c� ZZO � yah O C �- �Nm U O J Z � � moo LG1 `e�►uta����t7so� o w STRUCTURAL ENG: BED Ld OTOc) ••. t�2 �,, I �- ��' G�? Y o Z O OS „y : U `t CU 0:z � J .. r0 w z Q o •IK �O�ee m U- ir�oronwo�e�'�`�,� 1) FOR HEADER DEPTHS DEEPER THAN 32", USE VALUES FOR 32" DEEP HEADER QUANTITY OF #5 REBAR AT TOP 4 2) FOR HEADER DEPTHS NOT LISTED ON CHART, USE THE VALUES FOR THE NEXT DEPTH DOWN. O 8RF14-1B/1T NOMINAL HEIGHT � l ; NOMINAL WIDTH l 0 20'-8" 9'-6" 8 F 16-16/ 1 T cn TYPE DESIGNATION OD DO. . .. . ...... . caLO 10 <01: �0 0 .V.IVI. .v.IVI. 9'-4" 8'-0" O M OF M LINTEL PLAN 1/8"= 1 "-0" O 8RF14-OB/1T � 4.0 OI•t� � N F 8F16-OB/1T 1-1/2" CLEAR � U O 8F20-1B/1T Q � EA�Z_#5 REBAR AT TOP MIN. (1) REQ'Dao08F20-OB/1 T �zC.M.U. Z8RF22-16/1T � GROUT � z #5 REBAR AT BOTTOM OF LINTEL � V Z O 8F24-1B/1T � � CAVITY cp O 8RF22-OB/1T �* BOTTOM REINFORCING PROVIDED c o� 7-5/8 ACTUAL IN LINTEL (VARIES) O8" NOMINAL WIDTH 8F24-OB/1 T 0" 8RF30-1B/1T FILLED P G� O 8F32 -16/1T 1-1/2" CLEAR a 0 8RF30-OB/1T � 0 � z ° #5 REBAR AT TOP MIN. (1) REQ'D � Z O 8F32 -OB/1T v � C7 Q z C.M.U. G7 v 0 8F38 -1B/1T � g o W �� g �O z � LIJ ZI—Mr' 11 E 0 8F12-1B/1T �� � O� z� u� O 8F40 -OB/1T BOTTOM REINFORCING PROVIDED � J Z o � o � 0,00 3 7-5/8" ACTUAL IN LINTEL (VARIES) � ^ � � � w O 8F8 -OB/1T 8" NOMINAL WIDTH j Q 0 o N UNFILLED 15 � —Lu LO 0 Ln 0 S5 j � ° ~ � w �' OZ Z =cn~z E SAFE LOAD TABLE NOTES Q N wN¢ 1. ALL VALUES BASED ON MINIMUM 4" NOMINAL BEARING. EXCEPTION: SAFE LOADS FOR UNFILLED � � 7 Z � U LINTELS MUST BE REDUCED BY 20% IF BEARING LENGTH IS LESS THAN 6-1/2". SAFE LOADS FOR ALL O RECESSED LINTELS BASED ON 4" NOMINAL BEARING. � � � 2. 0 =NOT RATED. ®A 3. SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOAD ON THE SECTION SPECIFIED. W W 4. SAFE LOADS BASED ON GRADE 40, GRADE 60 MAY BE USED WITHOUT WRITTEN APPROVAL FROM EOR = 5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE DESIGNER BY PROVIDING � � ADDIONAL REINFORCED MASONRY ABOVE THE PRECAST LINTEL. S 6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" LINTELS ONLY. 7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING MOMENT AND SHEAR AT D -AWAY FROM THE FACE OF SUPPORT. 8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE LOAD FROM NEXT LOWER HGT. 9. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. � W 11 Z N c� ZZO � yah O C �- �Nm U O J Z � � moo DATE: 10!11!2016 STRUCTURAL ENG: BED DRAFTING: -STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10!11!2016 (1) #5 FROM FTG. TO — (1) #5 FROM FTG. TO FINISH PER ELEV. w Lu TIE BEAM SPLICE TO a1 I'� TIE BEAM SPLICE TO FINISH FLOOR BE MIN. 25" GROUT PENETRATING .` BE MIN. 25" GROUT da a CELL SOLID w d CELL SOLID II 00 0oso0ooa�� �I MASONRY WALL I MASONRY WALL da'. PIPE SIZES LARGER SEE PLAN I� SEE PLAN PENETRATING PIPE (SIDE VIEW) DENSITY CONCRETE SLAB PER w CONCRETE SLAB PER w FOUNDATION PLAN `Ila FOUNDATION PLAN P O I. VARIES a SEE PLAN I w m 00 I� 4' ta. d GRADE Ld Q L. l GRADE z c_j o 0 CL Of N J o Cw7 — %a — --ml z a I — I i- Z 00 .I > - ry Q 10111 11 ,� e d IU o - a) _w Ur > o D 1-- da d - _� (2) #5 BARS CONT. I __ I — I I3' I (2) #5 BARS CONT. TYP. CLEAN COMPACTED W/ 3" COVER TYP. C R' CLEAN COMPACTED W/ 3" COVER 3'' C V R FILL @ 95% STANDARD F� FILL @ 95% STANDARD DENSITY 1'4" DENSITY lie Ilk WHERE 2ND STORY OCCURS, FTG WHERE 2ND STORY OCCURS, FTG SHALL BE 1'-4" WIDE w/(3) #5 BARS SHALL BE 1'-4" WIDE w/(3) #5 BARS AFO TYPICAL EXTERIOR FOOTING AFO TYPICAL GARAGE CURB FOOTING e d 3/4"=1'-0" 3/4"=1 '-0" OPT. MASONRY CURB @ ELEV. 0'-0" w/ (1) #5 11 ' I CONT. BAR Z N SLOPED GROUT TO DRAIN A Z 0 Z OPTIONAL CURB BY BUILDER II IF BRIG. WALL ABOVE- HOLD BRIG WALL BACK 2x BRIG WALL PER 2x BRG WALL PER w 1/2" J -BOLT W/ MIN. 6" SO GYP FINISH IS PLAN AND BEARING PLAN AND BEARING Q PAST DEEPEST STEP FLUSH w/ FOUNDATION WALL SCHEDULE WALL SCHEDULE U) REQ'D MIN 4" BELOW w CONC. SLAB PER (1) #5 CONT. w/ 1-1/2" 1 FOUNDATION PLAN COVER TYP. 1-1/2" COVER TYP. CONC. SLAB PER FOUNDATION PLAN 2 1/4 1 CONC. SLAB PER CONCRETE SLAB PER FOUNDATION PLAN Q FOUNDATION PLAN w z w 2x PT SILL PLATE 2x P.T. SILL PLATE a of z a¢LuI Al III—' '� I mmlm I -I I I I I I I I S lo 16" 8" 8" w CLEAN COMPACTED O (2) #5 BARS CONT, w/ 3" CLEAN COMPACTED (2) #5 BARS CONT. w/ 3" CLEAN COMPACTED FILL @ 95% STANDARD U COVER TYP.; AT 8Ile" 8" FILL @ 95% STANDARD COVER TYP.; AT FILL @ 95% STANDARD DENSITY (2) #5 BARS CONT. w/ 3" m 2 -STORY COND. (3) #5 DENSITY 2 -STORY COND. (3) #5 DENSITY COVER TYP.; AT CLEAN COMPACTED BARS REQ'D & FTG TO BARS REQ'D & FTG TO 2 -STORY COND. (3) #5 FILL @ 95% STANDARD BE 20" WIDE BE 20" WIDE BARS REQ'D & FTG TO DENSITY BE 20" WIDE NON-BEARING SLAB STEP DOWN #FO� DOUBLE STEP FOOTING VERIFY W/ DETAILS FOR REQ'D STEEL AT 2 STORY LOCATIONS MIN. 24" BEFORE z CONC. SLAB PER 8"x12" THICKENED ANOTHER STEP 8„ a CONC. SLAB PER FOUNDATION PLAN SLAB w/ (1) #5 CONT. FOUNDATION PLAN w13" CnVFR TYP I 3/4"=1'-0" V-4" (2) #5 BARS CONT. W/ 3" COVER TYP. (y) COVER TYP. (2) #5 BENT BARS w/ CLEAN COMPACTED MIN. 25" LAP SPLICE WHERE 2ND STORY OCCURS, FTG FILL @ 95% STANDARD SHALL BE V-4" WIDE w/(3) #5 BARS DENSITY AFO FOOTING @ SHOWER AT MASONRY F08 THICKENED EDGE 0*9TYPICAL STEP FOOTING DETAIL 3/4"=1'-0" 3/4"=1'-0" ® FILLED CELL PER PLAN WOOD POST PER PLAN FOR SIZE AND BASE ~-- 4„ CONNECTION — GARAGE TOP COURSE TO BE —� \ CHAIR BLOCKS. _____—a ENTIRE BASE TO BE FILLED SOLID \ TOP VIEW CORNER \\ SEE ELEVATION CMU BASE w/ (1) #5 CONC. SLAB PER FOUNDATION PLAN GARAGE WALL VERTICAL @ EACH PLAN FOR BASE SIZE BEYOND CORNER. SEE FLR. I O DRIVEWAY BY I SEE FOUNDATION FOR 1 1 4, BUILDER- CONCRETE PAD SIZE F— w M OR PAVERS I I w CONC. SLAB OR I > w PAVERS PER PLAN l I cn 1—� I`^ CLEAN COMPACTED I i FILL @ 95% STANDARD I I DENSITY _ ... 8" x 8" THICKENED I I " j- • , -t • ; ��' g 3 COVER TYP. EDGE w/ (1) #5 CONT. TED FILE @ 95%O STANDARD I I DENSITY F1 THICKENED EDGE @ GARAGE DOOR 91 FOOTING @ ENTRY MASONRY COLUMN 3/4"=1'-0" 8"CMU - I. d ' Id . FINISH PER ELEV. w Lu e FOUNDATION PLAN CO2Q FINISH FLOOR PENETRATING .` da a GRADE d - i w d M v 00 0oso0ooa�� �I PVC SLEEVE MIN.— — FOOTING PER PLAN . l' da'. PIPE SIZES LARGER CLEAN COMPACTED THAN THE FILL @ 95% STANDARD PENETRATING PIPE (SIDE VIEW) DENSITY `� ' 0 d 00, Lu co w Z Q Z�m U paU) c�wz_C°� Q O F— J =Q (1) zQ� 00�zm (!J 0 I=-2,wui o —8 Z 4' ao Q o 0 CL Of N J _I Lu a I 10111 11 1 da d _� LJ I I -I d W L F� e d 3/4"=1'-0" V-4" (2) #5 BARS CONT. W/ 3" COVER TYP. (y) COVER TYP. (2) #5 BENT BARS w/ CLEAN COMPACTED MIN. 25" LAP SPLICE WHERE 2ND STORY OCCURS, FTG FILL @ 95% STANDARD SHALL BE V-4" WIDE w/(3) #5 BARS DENSITY AFO FOOTING @ SHOWER AT MASONRY F08 THICKENED EDGE 0*9TYPICAL STEP FOOTING DETAIL 3/4"=1'-0" 3/4"=1'-0" ® FILLED CELL PER PLAN WOOD POST PER PLAN FOR SIZE AND BASE ~-- 4„ CONNECTION — GARAGE TOP COURSE TO BE —� \ CHAIR BLOCKS. _____—a ENTIRE BASE TO BE FILLED SOLID \ TOP VIEW CORNER \\ SEE ELEVATION CMU BASE w/ (1) #5 CONC. SLAB PER FOUNDATION PLAN GARAGE WALL VERTICAL @ EACH PLAN FOR BASE SIZE BEYOND CORNER. SEE FLR. I O DRIVEWAY BY I SEE FOUNDATION FOR 1 1 4, BUILDER- CONCRETE PAD SIZE F— w M OR PAVERS I I w CONC. SLAB OR I > w PAVERS PER PLAN l I cn 1—� I`^ CLEAN COMPACTED I i FILL @ 95% STANDARD I I DENSITY _ ... 8" x 8" THICKENED I I " j- • , -t • ; ��' g 3 COVER TYP. EDGE w/ (1) #5 CONT. TED FILE @ 95%O STANDARD I I DENSITY F1 THICKENED EDGE @ GARAGE DOOR 91 FOOTING @ ENTRY MASONRY COLUMN 3/4"=1'-0" 1=141 TYPICAL FOUNDATION PENETRATIONS j 3/4"=1'-0" 3/4"=1'-0" NOT USED 3/4"=1'-0" (FRONT VIEW) BEARING SLAB STEP DOWN 3/4"=1'-0" VERIFY W/ DETAILS FOR REQ'D STEEL AT 2 STORY LOCATIONS de I" I '7 �ld d m' I d #5 CONT. is I REINFORCEMENT SEE FOUNDATION PLAN IF ,. FOR QUANTITY I THRESHOLD PER MFG 114—, #5 x 25" x 25" CORNER v7 w U w a A 6" M d SLOPE PER MFG 3/4"=1'-0" v OR m FOOTING AT INTERIOR BEARING 8"CMU - U) FINISH PER ELEV. CONC. SLAB PER FOUNDATION PLAN CO2Q FINISH FLOOR PENETRATING .` PIPE ®e19A{1111//0/ GRADE d - i w d M v 00 0oso0ooa�� �I PVC SLEEVE MIN.— — FOOTING PER PLAN DIAMETER TO BE 2 Ly PIPE SIZES LARGER CLEAN COMPACTED THAN THE FILL @ 95% STANDARD PENETRATING PIPE (SIDE VIEW) DENSITY 1=141 TYPICAL FOUNDATION PENETRATIONS j 3/4"=1'-0" 3/4"=1'-0" NOT USED 3/4"=1'-0" (FRONT VIEW) BEARING SLAB STEP DOWN 3/4"=1'-0" VERIFY W/ DETAILS FOR REQ'D STEEL AT 2 STORY LOCATIONS de I" I '7 �ld d m' I d #5 CONT. is I REINFORCEMENT SEE FOUNDATION PLAN IF ,. FOR QUANTITY I THRESHOLD PER MFG 114—, #5 x 25" x 25" CORNER v7 w U w a A 6" M d SLOPE PER MFG 3/4"=1'-0" v OR m FOOTING AT INTERIOR BEARING U) CO2Q Z (D g� 3/4"=1 '-0" ®e19A{1111//0/ co p w d M v 00 0oso0ooa�� �I � W J co p Ly J r b ov os o0 2 ! 6�2 = Z C'6 `� ' 0 d 00, Lu co w Z Q Z�m U paU) c�wz_C°� Q MASONRY WALL ,�a ~ . Q ` Q 0f SEE PLAN p s' I 'r 000000®00004 • �� rY J CONC. SLAB PER (1) #5 FROM FTG. TO m u_ � P' Fe�� �° FOUNDATION PLAN TIE BEAM MIN. 25" SPLICE GROUT CELL IIILtollee SOLID PER PLANS u o e . BAR, ONE .r e a HORI ONTALR EA. v _-- a a.' dad _ I U :. o fyjt N m 4 j CONC. SLAB PER w I I I I —I — 14 a REBAR, TYP. U.N.O. FOUNDATION PLAN _ — _-___-_-a__ o z 5 � — o BARS CONT. I —1 I=) .I I=1 I I� I I-- I O (2) # SLOPE W/ 3" COVER TYP.; @ e ° " 2 -STORY CONDITION O 'I':I+'I'I'lll,4,i�lpll I.!: tiG4 PER MFG (3) #5 BARS w/ 20 h tiS SLOPE EXT. SURFACE WIDE FOOTING c OR GRADE 1/4„ PER CLEAN COMPACTED IZ FOOT AWAY FROM y FILL @ 95% STANDARD p 0 BUILDING 4' Q® DENSITY ELASTOMERIC JOINT FILLER � Q i TYPICAL CORNER BAR DETAIL (TOP VIEW) F1 EXTERIOR DOOR POURED SILL OF1 FOOTING AT INTERIOR BEARING WITH CMU 3/4"=1'-0” TOP (2) #5 x 4'-0" PVC OR SCH40 SLEEVE CENTERED AT PIP PENETRATION NOT USED 3/4"=1'-0" 3/4"=1'-0" U) CO2Q Z (D o v W Ly J r b ov Q C'6 LUZ H M E ai Z Z Q Z�m U paU) c�wz_C°� O F— J =Q (1) zQ� 00�zm (!J 0 I=-2,wui o Z < a zooLL E Q o 0 CL Of N J Lu LJ O W L Lu 11 Z N A Z 0 Z 0 J 0La c0 I— �Nm U O W Z �a0 _ o a0 ry CL STRUCTURAL ENG: BED DRAFTING: -STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 SD1 �� ... °.. ENTIRE COLUMN TO Q a A BE GROUT FILLED PROVIDE STANDARD FRAMING INF( U.N.O. CONT. ROOF SHEATHING NAIL PER PLAN III. r ° cn HOOK F SIDE OF DOOR, GROUT FILLED CELL (IF W WALL SCHEDI REQ'D PER PLAN) d d, d 4 PLATES OVER ROOF DECK PER VALLEY N LL FRAMING DETAIL REST EQ. SPACED 'eta ,a1: ;� .; ;; ,., �....:• ^24" O.C.) NOTE: SEE MD08 ON INDICATED ON GARAGE WALL LINTEL PLAN FOR SCHEDULE. MII BEYOND ADDIT'L REBAR INFO FROM END OF FINISH PER ARCHSFIN 0 (1) #5 IN TIE BEAM VERTICAL REINFORCEMENT DETAIL SIC NAILED @ 6" O.C. STAGGERED NOTE: SEE ARCH ELEVATION (1) #5 BAR IN PRECAST 1/4"=1'-0" NOTE: ROOF SHEATHING MUST BE APPLIED AND FASTENED TO BASE TRUSS PER PLANS BEFORE DORMER FRAMING IS INSTALLED. J p V SHEARWALL •�' Alt I' I W MIN. 2x4 SPF #2 KNEE LINTEL 2x4 #2 SYP RAT RUN 0-4 ly r1 �� "�1•. �.<:�,;1; ��1,;' TOP AND BOTTOM MI WALL w/ STUDS 16" @ (2) #5's VERTICAL IN NAILS (2) BAYS PAST A/C Z PLATE O.C. w/ STRUCTURAL GROUT FILLED CELL w 2x4 BLOCKING LAP W/ (2) 16d NAILS SHEATHING FROM o BETWEEN TRUSSES TO EACH TRUSS. TYF � 0 PRE-ENG.TRUSS PER TOENAILED TO EACH SIDE DOUBLE TOP PLATE w/ z¢� z PLAN, 24" O.C. MAX 10d NAILS @ 4" O.C. z O �� ... °.. ENTIRE COLUMN TO Q a SEE PLAN FOI BE GROUT FILLED w FRAMING INF( U.N.O. CONT. ROOF SHEATHING NAIL PER PLAN 5-1/2" EMBED, AT EA. CENTERED (1) #5 VERTICAL IN F SIDE OF DOOR, GROUT FILLED CELL (IF THREADED RO WALL SCHEDI REQ'D PER PLAN) h 4 PLATES OVER ROOF DECK PER VALLEY l FRAMING DETAIL REST EQ. SPACED REQUIRED WH ^24" O.C.) NOTE: SEE MD08 ON INDICATED ON GARAGE WALL LINTEL PLAN FOR SCHEDULE. MII BEYOND ADDIT'L REBAR INFO FROM END OF FINISH PER ARCHSFIN 0 MASONRY WAL VERTICAL REINFORCEMENT DETAIL SIC PRECAST LINTEL PER PLAN MASONRY WALL —� SEE PLAN 2x8 W/ (2) 16d TOE — NAILS EA. END 2x SPF CONT. BLOCKING ATTACH TO 7/16" OSB W/ (2) 8d NAILS 7/16" OSB EA. SIDE, W/ 6d NAILS @ 16" O.C. TO SIDE & TOP NAILER 12x BUCK PER MD04 THIS SHEET 1/2"=11-0" NOTE: CUT BACK 2x8 P.T. @ TOP TO ALLOW CONT. 2x4 BLOCKING AROUND CURVE. MIN. 2 TAPCON ANCHORS ARCH WINDOW FRAMING DETAILS PRE-ENGINEEF TRUSSES PER 24" 0. C. MAX. TYP. TRUSS TC CONNECTION I CONNECTION I EXT. SHEATHI� ATTACHED PEI NAILING SCHEI FROM TOP OF KNEEWALL TO OR SP2 CLIPS, AND SP1 CLIP BASE ARE REG 2x BLOCKING MIN 2x4 STUD O/C 2x P.T. PLATE 1/2" x 8" A.B. OF HID @32"O.C., FROM EA. END ON BASE PLAT TOP KNOCK OI COURSE W/ (1) CONT. fiR KNEEWALL ABOVE MASONRY WALL 3/4"=11-011 GARAGE BUCK DETAIL ARCH PER ELEV 2x6x12 P.T. CENTER 2x STUDS @ 16" O.C. FOR KNEE WALL SEE PLAN FOI BUCK /'v B O FRAMING INF( 3/8" DIA. ANCHOR CONT. ROOF SHEATHING NAIL PER PLAN 5-1/2" EMBED, AT EA. CENTERED DOOR BRACKET, EA, BASE PLATE SIDE OF DOOR, CONNECTION THREADED RO WALL SCHEDI THICK WASHER W/ EA. PLAN / BEARINi ANCHOR. (1st BOLT TO PLATES OVER ROOF DECK PER VALLEY SCHEDULE. ON FRAMING DETAIL REST EQ. SPACED REQUIRED WH ^24" O.C.) nT 0ACC of A INDICATED ON GARAGE WALL SCHEDULE. MII BEYOND STRUCTURAL SHEATHING PER PLAN AND ROOF FROM END OF FINISH PER ARCHSFIN 0 MASONRY WAL 2x6 P.T. BUCK EACH 2x STUDS @ 16" O.C. FOR KNEE WALL SIDE OF OPENING BLOCKING PE /'v B O WALL SCHEDI (5) 3/8" DIA.. J -BOLT W/ CONT. ROOF SHEATHING NAIL PER PLAN 5-1/2" EMBED, AT EA. PROVIDE 2x4 BLOCKING w/(2)16d NAILS EACH END DOOR BRACKET, EA, BASE PLATE SIDE OF DOOR, CONNECTION PROVIDE 1-1/2" x 3/16" WALL SCHEDI THICK WASHER W/ EA. PRE-ENGINEERED ROOF TRUSS PER PLAN BELOW ANCHOR. (1st BOLT TO PLATES OVER ROOF DECK PER VALLEY BE 8" MAX. ABV. CURB, FRAMING DETAIL REST EQ. SPACED TOP PLATE ^24" O.C.) nT 0ACC of A V1D0 BEARING/ SHEARWALL CONNECTION TO CMU 1/2"=1'4" 3/4"=1'4" LINTEL (SEE PLAN) SEE TYPICAL HEADER 7/16" O.S.B. EA. SIDE FRAMING DETAILS FOR ADDITONAL % INFORMATION j (HEADER CAN BE EITHER UPSET OR _ 2x BLK'G. TO O.S.B. W (2) - 8d EACH END END VIEW w/CMU __ HEADER (SEE PLAN) 7/16" O.S.B. EA. SIDE ARCH PER ELEV -- 2x BLK'G. TO O.S.B. W/ (2) - 8d EACH END END VIEW w/ WOOD DORMER FRAMING DETAIL IF REQ'D, PROVIDE CLOSURE WALL w/ SINGLE TOP AND BASE PLATE w/ (2) 16d NAILS TO TRUSS. STUDS @ 24" O.C. & EXT. SHEATHING INSTALLED PER NAILING PATTERN CRICKET AS REQUIRED MAIN SPAN ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MASONRY WALL PER PLAN 2x STUDS @ 16" O.C. FOR KNEE WALL CHORD WITH (4) 10d LSTA18 @ 32" O.C. STUD TO PRE -ENG TRUSS, SLIT /'v B O ROOF SHEATHING FOR STRAP CO CONT. ROOF SHEATHING NAIL PER PLAN KNEEWALL OVER MASONRY WALL PROVIDE 2x4 BLOCKING w/(2)16d NAILS EACH END HEADER PER LOCATION TO TOP CHORDS OF TRUSSES BELOW WHEN SHEATHING ON BOTH BOTTOM PLATE DOES NOT LINE UP ABOVE TRUSS IF NO WEB IS PRESENT BELOW AND CONNECT w/ HTS20 @ 32" O.C. O PRE-ENGINEERED ROOF TRUSS PER PLAN BELOW O2x PLATES OVER ROOF DECK PER VALLEY IF REQ'D, PROVIDE CLOSURE WALL w/ SINGLE TOP AND BASE PLATE w/ (2) 16d NAILS TO TRUSS. STUDS @ 24" O.C. & EXT. SHEATHING INSTALLED PER NAILING PATTERN CRICKET AS REQUIRED MAIN SPAN ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MASONRY WALL PER PLAN UF DOWNSET) 2x W/ (2) 16d TOE NAILS EACH END (3) 16d COMMON NAILS (TYP.) (2) 2x TOP PLATE TYPICAL TIE BEAM w/ 3000 psi CONC. w/(1) #5 REBAR CONT. STD HOOK 2x P.T. STUD TYPICAL FILLED CELL w/ 3000 psi CONC. w/(1) #5 REBAR VERT. VERIFY w/ PLAN FOR REQ'D LOCATIONS CMU WALL PER PLAN (4) EQ. SPACED 2" TITEN HD ANCHORS w/ MIN. 1 4" EMBED, FOR HOLLOW BLOCK OR 3 "'EMBED. FOR SOLID BLK. MAX. 6" FROM TOP & BOTTOM OR 4" x 4" TITENS w/ WASHERS 6" FROM TOP AND BOTTOM AND 12" O.C. OTHERWISE. NOTE: THIS DETAIL APPLIES TO THE FOLLOWING CONDITIONS: (1) EXTERIOR FRAME WALL TO CMU (2) INTERIOR FRAME SHEAR WALL TO CMU (3) INTERIOR LOAD BEARING FRAME WALL TO CMU WALL. SEE BEARING WALL SCHEDULE FOR CONNECTION INFORMATION. SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD. CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D 2x BUCK DETAIL ��— (2) 2x TOP PLATE (2) 2x PLATE —� 2x4 SPF CONT. 2x STUDS @ 16" O.C. FOR KNEE WALL CHORD WITH (4) 10d LSTA18 @ 32" O.C. STUD TO PRE -ENG TRUSS, SLIT /'v B O ROOF SHEATHING FOR STRAP CO CONT. ROOF SHEATHING NAIL PER PLAN KNEEWALL OVER MASONRY WALL PROVIDE 2x4 BLOCKING w/(2)16d NAILS EACH END STRUCTURAL TO TOP CHORDS OF TRUSSES BELOW WHEN SHEATHING ON BOTH BOTTOM PLATE DOES NOT LINE UP ABOVE TRUSS IF NO WEB IS PRESENT BELOW AND CONNECT w/ HTS20 @ 32" O.C. O PRE-ENGINEERED ROOF TRUSS PER PLAN BELOW O2x PLATES OVER ROOF DECK PER VALLEY SIDES FROM TOP OF FRAMING DETAIL ODOUBLE TOP PLATE OSIMPSON H3, H4, OR H5 @ EA. END OF TRUSS OR 7/16" OSB EACH SIDE, RAFTER TRUSS PER PLAN OR CONY. FRAMING w/ JOCOMMON STRUCTURAL SHEATHING PER PLAN AND ROOF NAILING SCHEDULE FINISH PER ARCHSFIN 0 ROOF TRUSSES PER PLAN OR CURVED OCURVED K RAFTERS w/ (2) LAYERS 3/4" CDX SHEATHING Oj�Vo NAILED @ 6" O.C. STAGGERED NOTE: SEE ARCH ELEVATION FOR FRONT WINDOW OPENING IF REQ'D 1/4"=1'-0" NOTE: ROOF SHEATHING MUST BE APPLIED AND FASTENED TO BASE TRUSS PER PLANS BEFORE DORMER FRAMING IS INSTALLED. UF DOWNSET) 2x W/ (2) 16d TOE NAILS EACH END (3) 16d COMMON NAILS (TYP.) (2) 2x TOP PLATE TYPICAL TIE BEAM w/ 3000 psi CONC. w/(1) #5 REBAR CONT. STD HOOK 2x P.T. STUD TYPICAL FILLED CELL w/ 3000 psi CONC. w/(1) #5 REBAR VERT. VERIFY w/ PLAN FOR REQ'D LOCATIONS CMU WALL PER PLAN (4) EQ. SPACED 2" TITEN HD ANCHORS w/ MIN. 1 4" EMBED, FOR HOLLOW BLOCK OR 3 "'EMBED. FOR SOLID BLK. MAX. 6" FROM TOP & BOTTOM OR 4" x 4" TITENS w/ WASHERS 6" FROM TOP AND BOTTOM AND 12" O.C. OTHERWISE. NOTE: THIS DETAIL APPLIES TO THE FOLLOWING CONDITIONS: (1) EXTERIOR FRAME WALL TO CMU (2) INTERIOR FRAME SHEAR WALL TO CMU (3) INTERIOR LOAD BEARING FRAME WALL TO CMU WALL. SEE BEARING WALL SCHEDULE FOR CONNECTION INFORMATION. SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD. CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D 2x BUCK DETAIL ��— (2) 2x TOP PLATE (2) 2x PLATE —� 2x4 SPF CONT. MIN. 2x4 SPF #2 KNEE ---- WALL WITH STUDS @ 16" O.C. W/ CHORD WITH (4) 10d (2) 2x #2 SYP SEE PLAN MIN. 2x4 SPF #2 KNEE WALL WITH STUDS @ 16" O.C. W/ 2x4 #2 SYP BLOCKINC BLOCKING ATTACH TO STRUCTURAL KNEEWALL OVER MASONRY WALL FOR BEAM SIZE STRUCTURAL VJ SHEATHING ON BOTH IF NO WEB IS PRESENT SHEATHING ON BOTH 7/16" OSB W/ (2) 8d SIDES FROM TOP OF (2) (2) 2x #2 SYP SEE PLAN I SIDES FROM TOP OF NAILS WALL TO BOTTOM OF I BUILDER FRAME WALL TO BOTTOM OF 7/16" OSB EACH SIDE, BEAM, ATTACHED PER RADIUS AS REQ'D BEAM. ATTACHED PER W/ 6d NAILS @ 16" O C NAILING SCHEDULE END 0 NAILING SCHEDULE TO SIDE & TOP NAILER OTHERWISE SP2 CLIPS 2x BUCKS, AT TOP AND SP1 CLIPS AT BASE ARE — REQUIRED filFO KNEEWALL AT DOWNSET BEAM NAIL SCAB TO TOP IF A/C 1S SUSPENDED CHORD WITH (4) 10d FROM TOP CHORD (2; NAILS 2x4 #2 SYP BLOCKINC ADD 2x4 VERTICAL REQ'D @ TOP CHORD KNEEWALL OVER MASONRY WALL SCAB IN EACH TRUSS ATTACHMENTS VJ l V IF NO WEB IS PRESENT SUPPLIED BY A/C � OR TITEN HD @ 32" (2) (2) 2x #2 SYP SEE PLAN I COMPANY 0 (3) 10d NAILS TYPICAL O.C. & 6" FROM EACH FOR BEAM SIZE (ONLY I IF OPENING PROVIDED J AT EACH TRUSS O END 2x4 'X' BRACE ACROSS �- Oj�Vo LENGTH OF I PER PLAN) w D J p V SHEARWALL m I' I W MIN. 2x4 SPF #2 KNEE NAIL SCAB TO TOP 2x4 #2 SYP RAT RUN 0-4 ly r1 �� rt N CHORD WITH (3) 10d TOP AND BOTTOM MI WALL w/ STUDS 16" @ NAILS (2) BAYS PAST A/C Z PLATE O.C. w/ STRUCTURAL LOCATION. MIN (3) BA OU 2x4 BLOCKING LAP W/ (2) 16d NAILS SHEATHING FROM o BETWEEN TRUSSES TO EACH TRUSS. TYF � 0 PRE-ENG.TRUSS PER TOENAILED TO EACH SIDE DOUBLE TOP PLATE w/ z¢� z PLAN, 24" O.C. MAX 10d NAILS @ 4" O.C. BOTTOM OF WALL. ATTACHED PER O Z STANDARD TRUSS -- TRUSS PER PLAN BOTTOM CHORD DOUBLE TOP PLATE LL w J FRAMED WALL PER PLAN 3/4"=1'-0" PRE -CAST LINTEL PER PLAN (2) 2x PT BUCKS w/ 1/2" O.S.B. BETWEEN IF DBL. NAILER IS USED, USE 1/4" x 4-1/2" TAPCONS; SEE NOTES FOR SPACING FASTEN PT 2x NAILER ATTACHMENT REQUIREMENTS SIZE TAPCONS SPACING # ROWS 2x4 3/16" x 3" 12" O.C. 1 2x8 3/16" x 3" 12" O.C. 2 TO MASONRY NOTES: 1. 2x PT BUCKS/NAILERS SHALL EXTEND BEYOND INT. FACE OF WINDOW, FASTEN BUCK TO MASONRY W/ (1) ROW OF 3/16"X4" TAPCONS 6" FROM ENDS AND 16" O.C. MAX. TAPCONS TO BE 1 1/2" MIN. FROM EDGE OF BUCK 2. BUCKS LESS THAN 2x TO BE FASTENED W/CUT NAILS OR EQUIVALENT, STRUCTURAL CONNECTION OF WINDOW TO STRUCTURE BY OTHERS IN THIS CASE. 3. ADDITIONAL 2x WOOD BUCK MATERIAL MAY BE ADDED TO EXISTING 2x BUCKED OPENING, USE (3) ROWS OF 10d x 3" NAILS STAGGERED @ 12" O.C. @ EACH SUCCESSIVE BUCK 4. MIXING OF 1x AND 2x BUCKS SHALL BE PERMITTED FOR THE SAME (1) 2x OR (2) 2x BUCK OPENING IF WINDOW MANUFACTURER AND PLAN REQUIREMENTS TBD BY BUILDER (FASTENING) ARE MET 5. ADDITIONAL WOOD BUCK MATERIAL MAY BE FASTENED TO 2x BUCK w/ (2) ROWS OF 8d NAILS @ 16" O.C. FASTEN WINDOW TO ?.x PER WIN. MANU.'S SPECS 1/2"=1'-0" SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD. CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D IF O CL Q o NW co STRUCTURAL ���� �, •••k ®• dJ�� ��i�i G� L ti SHEATHING ••• ••s �/6 % = Z U V TYP. TRUSS TO FRAME Q ��' u- dam; % (� p CONNECTION PER STD. CONNECTOR CO )' ,, oa• `_ d W Q d0 z ,,, Z NOTES : a z ` O Q of FRAME OUT TO BLOCK •'• } O EDGE �°•....•.•., e� fs'el�®# pR v PERP. SHEARWALL CONNECTION TO TRUSSB01 A/C IN TRUSSES 3/4"=1'-0" PRE -MANUFACTURED CHIMNEY CAP TOP OF CHIMNEY MIN Z-0" ABOVE A POINT WITHIN 10'-0" OF THE NEAREST ROOF (1) SPH4 EVERY -- OTHER STUD TO DOUBLE TOP PLATE 2x4 VERTICAL @ 24" O.C. MAX. w/ (4) 10d NAILS TO BOTTOM CHORD & (3) 10d NAIL; TO TOP CHORD; NOTE IF WALL HEIGHT IS BETWEEN 4FT & 8FT, USE 2x6 SYP #2 STUD; GALVANIZED FLASHIN 2x4BLOCKING W/ (2) 16d COMMONS END NAILED TO VERTICAL 2x4's 3/4"=1'-0" CHIMNEY FRAMING DETAIL 3/4"=1'-0" 3/4"=1'-0" ROOF SHEATHING ATTACH PER NAILING SCHEDULE STANDARD TRUSS TOP CHORD VARIES TRUSS WEBS NOT SHOWN FOR CLARITY 2x4 #2 SYP CROSS BRACING (AT 45°) W/ (3) 12d NAILS TO RAT RUNS. TYP EACH SIDE CONDENSATE DISPOSAL BY A/C SUPPLIER CONNECTION TO BE SUPPLIED BY A/C COMPANY (2) 2x4 #2 SYP BLOCKING W/ SIMPSON A34 OR LUS24-2 EACH END FLUE PER MANUF. SPECS W/ 2" MIN. CLEAR BETWEEN FLUE & FRAME GALVANIZED FLASHING EXT. SHEATHING ATTACHED PER NAILING SCHED. 2x4 FRAMED CRICKET W/ GALVANIZED FLASHING a I W KNEEWALL OVER MASONRY WALL 1/2" x 8" ANCHOR BOLT (2) 2x TOP PLATE VJ l V � OR TITEN HD @ 32" (2) (2) 2x #2 SYP SEE PLAN I 0 — (2) 2x #2 SYP SEE PLAN FOR BEAM SIZE O.C. & 6" FROM EACH FOR BEAM SIZE (ONLY I IF OPENING PROVIDED J � O END Q �- Oj�Vo o I PER PLAN) w D J p V O m I' I W MIN. 2x4 SPF #2 KNEE ��' 0-4 ly r1 �� rt N 2x PT BOTTOM WALL w/ STUDS 16" @ iiii'i'I,,,,,! Z PLATE O.C. w/ STRUCTURAL OU o fn �z2o 0 SHEATHING FROM o � � 0 PRE-ENG.TRUSS PER PRECAST LINTEL OR I TOP OF WALL TO z¢� z PLAN, 24" O.C. MAX KNOCK OUT COURSE BOTTOM OF WALL. ATTACHED PER O Z ROOFING MATERIAL uj LL w J PER ARCHS NAILING SCHEDULE N LLUNQ r--- SEE FRAMING PLAN J i- W Z O .4.OTHERWISE SP2 CLIPS c Z 09 U BUILDER FRAME MASONRY WALL AT TOP AND SP1 CLIPS a / rn F— 0 �titi L RADIUS AS REQ'D A,, AT BASE ARE REQ'D p W Lu O� Q® PERP. SHEARWALL CONNECTION TO TRUSSB01 A/C IN TRUSSES 3/4"=1'-0" PRE -MANUFACTURED CHIMNEY CAP TOP OF CHIMNEY MIN Z-0" ABOVE A POINT WITHIN 10'-0" OF THE NEAREST ROOF (1) SPH4 EVERY -- OTHER STUD TO DOUBLE TOP PLATE 2x4 VERTICAL @ 24" O.C. MAX. w/ (4) 10d NAILS TO BOTTOM CHORD & (3) 10d NAIL; TO TOP CHORD; NOTE IF WALL HEIGHT IS BETWEEN 4FT & 8FT, USE 2x6 SYP #2 STUD; GALVANIZED FLASHIN 2x4BLOCKING W/ (2) 16d COMMONS END NAILED TO VERTICAL 2x4's 3/4"=1'-0" CHIMNEY FRAMING DETAIL 3/4"=1'-0" 3/4"=1'-0" ROOF SHEATHING ATTACH PER NAILING SCHEDULE STANDARD TRUSS TOP CHORD VARIES TRUSS WEBS NOT SHOWN FOR CLARITY 2x4 #2 SYP CROSS BRACING (AT 45°) W/ (3) 12d NAILS TO RAT RUNS. TYP EACH SIDE CONDENSATE DISPOSAL BY A/C SUPPLIER CONNECTION TO BE SUPPLIED BY A/C COMPANY (2) 2x4 #2 SYP BLOCKING W/ SIMPSON A34 OR LUS24-2 EACH END FLUE PER MANUF. SPECS W/ 2" MIN. CLEAR BETWEEN FLUE & FRAME GALVANIZED FLASHING EXT. SHEATHING ATTACHED PER NAILING SCHED. 2x4 FRAMED CRICKET W/ GALVANIZED FLASHING (4) 16d COMMONS , . ELEV 0'-0" a �' NAILED @ EACH END CONC. SLAB - �. SEE FOUNDATION VERT REINF. BEYOND — — STRUCTURAL ENG: BED 2x4 BLOCKING W/ (2) PLAN FOR MORE INFO -------------- 16d COMMONS END I i I DRAFTING NAILED TO VERTICAL MASONRY WALL PER-STRUCT: TNT 2x4's _ PLAN QC CHECK: CIr C SEE FOUNDATION JOB No. TM - 2153194 DETAILS FOR FTG INFO TRUSS PER PLAN SCALE: AS INDICATED DATE 10/11/2016 TYPICAL ONE STORY CMU WALL SECTION 3/4"=1'-0" SD2 a W KNEEWALL OVER MASONRY WALL VJ J � O Q �- o w D J p V I' I W 06 W 0 IW- M E z _ u_ a V 0 Z q�W(_ "wZ! c J fn �z2o 0 <Z Q 0 0 (00 T C PRE-ENG.TRUSS PER z¢� z PLAN, 24" O.C. MAX IJ...0 O z E � o a ROOFING MATERIAL uj LL w J PER ARCHS Q N LLUNQ r--- SEE FRAMING PLAN J i- W Z O O FOR CONNECTION INFO F— 0 SEE ELEVATION OgL W Lu 4 TOP OF MASONRY SEE ARCH PLANS FOR OVERHANG INFO RE. ELEV. FOR O.H. TYP. SINGLE TIE -BEAM W/ (1) #5 CONT. GROUT SOLID O U 11 uj WINDOW PER W) N FLOOR PLAN O ZZ0 O PRECAST CONC. OR (n Q POWERS STEEL SILL U) Y 1 TYP. @ ALL WINDOWS OLb P 'd EXT FINISH PER PLAN c0 CV m (� QJZ uj X00 °rhe MAIN FLOORO Q OOIL _ 11, w (4) 16d COMMONS , . ELEV 0'-0" a �' NAILED @ EACH END CONC. SLAB - �. SEE FOUNDATION VERT REINF. BEYOND — — STRUCTURAL ENG: BED 2x4 BLOCKING W/ (2) PLAN FOR MORE INFO -------------- 16d COMMONS END I i I DRAFTING NAILED TO VERTICAL MASONRY WALL PER-STRUCT: TNT 2x4's _ PLAN QC CHECK: CIr C SEE FOUNDATION JOB No. TM - 2153194 DETAILS FOR FTG INFO TRUSS PER PLAN SCALE: AS INDICATED DATE 10/11/2016 TYPICAL ONE STORY CMU WALL SECTION 3/4"=1'-0" SD2 (IMPSON 11- DIAGONAL DIAGONAL TO BEAM SIMPSON HGA10 @ 48" O.C. SHEATHING NOT REQ'D TO BE CONT. @ THE TRANSITION FROM BEAM TO GABLE TRUSS BEAM PER PLAN BEAM CONNECTION SIMPSON F DIAGONAL PLATE SIMPSON HGA10 @ 48" O.C. NOTE: ALL GABLE BRACING IS TO BE SHEATHING NOT REQ'D SYP#2 OR BETTER TO BE CONT. @ THE TRANSITION FROM WALL TO GABLE TRUSS DOUBLE 2x TOP PLATE FASTEN SIDE WALL SHEATHING PER PLAN. (5) 16d NAILS BRACE TO BLOCKING EXT. SHEATHING; ATTACH PER PLAN FRAME WALL CONNECTION GABLE END @ FLAT CEILING CONNECTIONS 2x4 BLOCKS, (2)16d NAILS @ EA. END. BLOCK ADJ BAYS @ EA. DIAL. AS SHOWN. FASTEN ROOF SHEATHING TO BLOCKS W/ 8d NAILS @ 6" O.C. (4) BAYS MIN (1) BAY AFTER BRACE IS REQ'D) PROVIDE 2x4 BRACE - TO EA. ADJ. DIAL. FASTEN TO DIAG. w/(2) 16d NAILS. GABLE BRACING @ 48" O.C. NOT REG'D 6' FROM EAVES GABLE BRACING CHART CONTRACTOR TO FIELD VERIFY WHICH GABLE BRACING + UP TO 4'-8" NO BRACE REQUIRED CONDITION IS REQUIRED. CONTACT EOR 7'-0" < H:6 9'-4" (2) 2x4 BRACE (SEE SECTION A -A) 9'-4" < H614'-0" FOR ADDITIONAL INFO AS REQ'D 14'-0" < H:618'-8" STRONGBACK W/ (2) 2x4 BRACE BLOCKS w/8d NAILS SIMPSON A23 @ EACH A35 DIAGONAL TO FOR NAILING @ 6" O.C. '4' BRACE TO PLATE TRUSS BOT. CHORD O.H. ROOF SHEATHING 3 1/4" HOLD 1/2" J -BOLTS w/ LLI ,, ••" °�Z ••••••••R, Q (� s >- O PT 2x8 PLT., CANT. FOR -r WASHERS (MIN. 7" 2x4 0 CLG. NAILING SURFACE ol EMBED) MIN. 6" FROM 2x4 SYP #2 BRACING @ d 24" O.C. END NAILS EA. END (TYP.) (END NAIL PLTS. EACH END AND 32" O.C. 24" O.C. FOR FALSE BM ~ Lu MAX. ATTACHMENT w/ (3) 10d TO STUD) _ O TOENAILS EA. END cn PROVIDE 16dNAILS GABLE END TRUSS TO ¢ ch 2x TOP PLATE TOILL PLT.@12" O.C. MAX. = v GABLE END W/ 16d p m O NAILS @ 6" O.C. END NAILS @ EA. 2x4 #2 SYP P.T. FRAMING FOR FALSE - L L x CMU WALL OR LINTEL a HGAIOKT @ 32" O.C. BEAM, IF REQ'D w/ (3) BELOW -- 10d NAILS @ EA. TRUSS BLOCKING @ 24" O.C. (2) 16d TOE NAILS ---- -\-TIE BRACE O.C. MAX. w/ (2) 16d BEAM COURSE w/ (1) 2x4 STUDS @ 24" O.C. w/ - - `-- SIMPSON H2.5(TYP.) #5 CONT. SINGLE BASE & TOP BRACE TO LEDGER PLATE w/ PLYWOOD FALSE BM PER PLAN SHEATHING COVERING IF REQ'D CMU WALL CONNECTION CLEAR SPAN CONNECTION ***NOTE: REFER TO DETAIL GE02 THIS PAGE FOR GABLE BRACING*** GABLE END @ FLAT CEILING CONNECTIONS 2x4 BLOCKS, (2)16d NAILS @ EA. END. BLOCK ADJ BAYS @ EA. DIAL. AS SHOWN. FASTEN ROOF SHEATHING TO BLOCKS W/ 8d NAILS @ 6" O.C. (4) BAYS MIN (1) BAY AFTER BRACE IS REQ'D) PROVIDE 2x4 BRACE - TO EA. ADJ. DIAL. FASTEN TO DIAG. w/(2) 16d NAILS. GABLE BRACING @ 48" O.C. NOT REG'D 6' FROM EAVES GABLE BRACING CHART H GABLE BRACING + UP TO 4'-8" NO BRACE REQUIRED 4'-8" < H 4 7'-0" (1) 2x4 BRACE 7'-0" < H:6 9'-4" (2) 2x4 BRACE (SEE SECTION A -A) 9'-4" < H614'-0" STRONGBACK W/ (1) 2x4 BRACE 14'-0" < H:618'-8" STRONGBACK W/ (2) 2x4 BRACE 2x4 BRACE IF REQ'D WHERE O.H. IS > 1'-0", DROP GABLES w/ OUTLOOKERS @ 24" O.C. V-0" MAX PLYOOD CANT. O.H. 2x4 BLOCKS, (2) 16d TO RUN BACK TO 1 ST COMMON SEE ELEV. FOR NAILS @ EA. END. TRUSS WITH (3) 12d TOENAILS. O.H. SIZE BLOCK ADJ. BAYS C CONNECT TO DROP GABLE WITH EA.DIAG. AS SHOWP H2.5 CLIP. MAX Z-0" O.H. FASTEN ROOF SHEATHING TO ECT TO DROP BLOCKS w/8d NAILS HORIZONTAL (+/- 10) WITH H2.5 CLIP. FOR NAILING @ 6" O.C. SEE GABLE -- CONNECTION DETAIL FOR REQ'D CONNECTIONS 2x4 ATTACHED TO EA. - GABLE 2x4 BRACE WITH (2) 10d NAILS SEE CHART. 10d COMMON NAILS (1) A23 FROM @ 6" O.C. STRONGBACK TO DIAGONAL GABLE VERTICAL 2ND 2x4 BRACE IF REQ'D, SEE CHART A -A GABLE VERTICAL BRACING 2x6 GABLE END BRACING 10d COMMON NAILS @ 8" O.C. 45° w CONT. 2x4 2x4 DIAGONAL BRACE @ 48" O.C. TO 3RD BAY REQ'D w/ STRONGBACK, SEE CHART \—GABLE BRACING (+) SEE CHART STRONGBACK IF REQ'D PER CHART (5) 16d NAILS BRACE TO BLOCKING A PROVIDE 2x4 BRACL FHING PER PLAN E O.H. IS > V-0" END GABLE w/ III JOKERS @ 24" z 0 RUN BACK TO 9 O DMMON TRUSS O.C. MAX. 45° FROM 2x4 BLOCKING @ EA. ;3) 12d TOENAILS. ~ ECT TO DROP `C ••� 0 � HORIZONTAL (+/- 10) WITH H2.5 CLIP. FOR NAILING '4' 2x4 BLOCKING (2) 12d V O.H. ROOF SHEATHING U) LLI ,, ••" °�Z ••••••••R, Q (� s >- O PLAN SPAN 2'-0") w/ (2) 16d 2'-0" MAX. 2x4 0 EACH END.AT 24" O.C. ROOF SHEATHING d 24" O.C. END NAILS EA. END (TYP.) (END NAIL PLTS. END FHING FASTEN TO STUD) GABLE END TO EA. ADJ. DIAG. PER PLAN A SHEATHING FASTEN FASTEN TO DIAG.w/(2) PER W SPLICE AS REQ'D PER PLAN. 16d NAILS. �-- SIMPSON H10A DIAG. rrai' o TO BLOCKING ``e®®r �(�®/�'' N W M �V �• ®O®•�® 00 G LLj 00 Z 3/4"=1'-0" FIELD FRAMED VALLEY DETAIL 1/2"=V-0" 2x8 RIDGE BOARD 2x6 COLLAR TIE HALF WAY UP HEIGHT OF VALLEY. FASTEN w/ (5) 10d COMMON NAILS @ EACH END (TYP.) 2x6 RAFTER TO 2x8 TRUSS PER PLAN RIDGE BOARD W/ A35 ON (1) SIDE OF RAFTER & A35 ON ADJ RAFTER TO OPP SIDE (AS SHOWN) 2x6's @ 24" O.C. MAX. EPSON DTC, (2) 8d ILS INTO BLOCKING, 8d NAILS TO TOP 4TE USS PER PLAN FASTEN SYP OR SPF 2x4 SYP #2 BLOCKING, 2x6 (MIN.) PLATE THRU @ 24" O.C. W/ (2) 12d SHEATHING PER PLAN END NAILS @ EACH Wr W/ 1/4"x4-1/2" SIMPSON END. TRUSS PER PLAN DTC CLIP, (2) 8d NAILS INTO BLOCKING, (2) 3/16" x 2 3/4" TAPCONS IN CMU. OR SIMPSON META16 AT 24" O.C. SDS SCREWS TO TOP WALL SHEATHING PER LAY 2x4 BLOCKING CHORD OF EACH PLANLINTEL PER PLAN OVER THE TOP OF THE TRUSS BELOW BOTTOM CHORD. FASTEN CONV. 2x 2x WALL, SEE PLAN ATTACH W/ (2) 10d VALLEY RAFTER NAILS @ EACH TRUSS FRAMING (OR PRE -ENG AT 24" O.C. VALLEY TRUSSES) TO STD CONDITION @ FRAME WALL BEARING CONDITION @ CMU WALL 2x PLATE WITH SIMPSON MTS12 OR LSTA12 & (5) 8d NAILS @ EA. RAFTER TO PLT. fi4 NON-BEARING WALL CLIP DETAIL 3/4"=1'-0" GABLE BRACING @ 48" JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 PROVIDE 2x BLOCKING w w, 4( cr mc:) Q U : Z O.C. MAX. 45° FROM 2x4 BLOCKING @ EA. PROVIDE 2x BLOCKING FOR NAILING `C ••� 0 � HORIZONTAL (+/- 10) OUTLOOKER (MAX. FOR NAILING 2x4 BLOCKING (2) 12d 6. • $ w < 4 •"".. ROOF SHEATHING PER ROOF SHEATHING (2)16d NAILS PLT. TO NAILS, TOENAILED @ ,, ••" °�Z ••••••••R, Q (� s >- O PLAN SPAN 2'-0") w/ (2) 16d 2'-0" MAX. /� STUD TOP & BOTTOM EACH END.AT 24" O.C. ROOF SHEATHING END NAILS EA. END (TYP.) (END NAIL PLTS. PER PLAN TO STUD) TRUSS PER PLAN DTC CLIP, (2) 8d NAILS - -- 2x FASCIA w (2) 16d INTO BLOCKING, (4) 8d END NAILS @ EA. 2x4 #2 SYP P.T. x NAILS INTO TOP PLATE 2x4 OUTLOOKER @ 24" -- -,_.__.OUTLOOKER BLOCKING @ 24" O.C. (2) 16d TOE NAILS ---- O.C. MAX. w/ (2) 16d `-- SIMPSON H2.5(TYP.) W/(2)12d END NAILS BRACE TO LEDGER END NAILS TO TRUSS -- HOLD WALL 3-1/2" @ EACH END DOWN FOR DOUBLE TOP PLATE 1'loo,-9" MAX. __ OUTLOOKER TRUSS PER PLAN 2x4 LEDGER W! (2) 10d TRUSS PER PLAN ` - ~ HEADER PER PLAN IF NAILS @ EACH WEB REQ'D. MIN (1) JACK & EXTERIOR SHEATHING. (1) KING STUD w/ SIMPS. TRUSS PER PLAN Q ATTACH PER PLAN LSTA18 HEADER TO w FROM TOP OF WALL VARIES STUDS TYP. BASE ui TO BOTTOM RAKED DOUBLE TOP CONNECTION m j2x8 #2 SPF STUDS AT PLATE — SHEATHING PER PLAN 16" O.C. CEILING NAILER AS -- 1/2" x 8" J -BOLT @ 32" DTC CLIP, (2) 8d NAILS NOTE: PROVIDE ADDIT'L REQ'D _r- --� O.C. AND 6" FROM EA. INTO BLOCKING, (2) MASONRY WALL OR 2x8 #2 SYP PT. BASE BLOCKING AS REQ'D 2x8 #2 SPF STUDS @ END w/ NUT & WASHER MASONRY WALL OR 3/16" x 2 3/4" TAPCONS LINTEL SEE PLAN PLATE W/ 1/2" x 8" PER HIB -91 & TRUSS 16" O.C. TYP. MSTAM-24 TYP. EA. LINTEL SEE PLAN "° IN CMU. OR SIMPSON ANCHOR BOLT OR MANU.'S DRAWINGS; �A--- SIDE OF EA. STUD. _- META16 TITEN HD @ 32 O.C. & CEILING GYP. BD. IS 2x8 #2 SYP PT BASE-jL ,�� CENTERED BETWEEN 6" FROM EACH END NOT A DIAPHRAGM PLATE FRAME AND CMU SEE WALL SPLICE DETAIL STD CONDITION @ CMU VAULTED CONDITION @ CMU CMU WALL PER PLAN FOR REQ'D FLASHING 6E4 GABLE END @ VAULTED CEILING 3/4"=1'-0" FIELD FRAMED VALLEY DETAIL 1/2"=V-0" 2x8 RIDGE BOARD 2x6 COLLAR TIE HALF WAY UP HEIGHT OF VALLEY. FASTEN w/ (5) 10d COMMON NAILS @ EACH END (TYP.) 2x6 RAFTER TO 2x8 TRUSS PER PLAN RIDGE BOARD W/ A35 ON (1) SIDE OF RAFTER & A35 ON ADJ RAFTER TO OPP SIDE (AS SHOWN) 2x6's @ 24" O.C. MAX. EPSON DTC, (2) 8d ILS INTO BLOCKING, 8d NAILS TO TOP 4TE USS PER PLAN FASTEN SYP OR SPF 2x4 SYP #2 BLOCKING, 2x6 (MIN.) PLATE THRU @ 24" O.C. W/ (2) 12d SHEATHING PER PLAN END NAILS @ EACH Wr W/ 1/4"x4-1/2" SIMPSON END. TRUSS PER PLAN DTC CLIP, (2) 8d NAILS INTO BLOCKING, (2) 3/16" x 2 3/4" TAPCONS IN CMU. OR SIMPSON META16 AT 24" O.C. SDS SCREWS TO TOP WALL SHEATHING PER LAY 2x4 BLOCKING CHORD OF EACH PLANLINTEL PER PLAN OVER THE TOP OF THE TRUSS BELOW BOTTOM CHORD. FASTEN CONV. 2x 2x WALL, SEE PLAN ATTACH W/ (2) 10d VALLEY RAFTER NAILS @ EACH TRUSS FRAMING (OR PRE -ENG AT 24" O.C. VALLEY TRUSSES) TO STD CONDITION @ FRAME WALL BEARING CONDITION @ CMU WALL 2x PLATE WITH SIMPSON MTS12 OR LSTA12 & (5) 8d NAILS @ EA. RAFTER TO PLT. fi4 NON-BEARING WALL CLIP DETAIL 3/4"=1'-0" GABLE BRACING @ 48" JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 PROVIDE 2x BLOCKING w w, 4( cr mc:) Q U : Z O.C. MAX. 45° FROM FOR NAILING `C ••� 0 � HORIZONTAL (+/- 10) 6. • $ w < 4 •"".. BRACE NOT REQUIRED 6' FROM EAVES. TRUSS PER PLAN ,, ••" °�Z ••••••••R, Q (� s >- O SEE PLAN FOR It111Um LL tA SUPPORT AND TIE DOWN OF JACK PROVIDE BLOCKING TRUSSES r l BETWEEN TRUSS BAYS V O @ 48" O.C. FOR FIRST 3 BAYS SEE GABLE WALL PER PLAN w 4or CONNECTION DETAIL O 1y m (FRAME WALL SHOWN; c a ;r , Ofyl d� v CONNFOR ECTIONS MAY ALSO BE j 13 0 MASONRY) IIID O ***NOTE: GABLES SPANNING LESS THAN 8' DO NOT REQUIRE BRACING*** p� ° o 0 • z� I,�i!V!I tiG� rr ll • Y 1ti 0 0 •... 0 W � Q GABLE END @ FLAT CEILING w/ BOSTON HIP 3/4"=11-011 (2) 2x TOP PLATE SEE GE02/SD3 FOR OUTLOOKER ORJ z SHEATHING _ CANTILEVER 8d NAILS @ 4" O.C. o W J � Q CONV. FRAME OR 0- HEADER PER PLAN; GABLE TRUSS c oZS w z o SEE HEADER VALLEY TRUSSES PER 9 U) 0 SCHEDULE & NOTES PLAN w Ur Q z u rn o� FOR ADDT'L INFO. EXT. SHEATHING; Z UO g o a SIMPSON LSTA12 OR0 w z ATTACH PER NAILING I-- cn SP4 CONNECTORS @ SCHED. Q 0 0 24"o.c. IF HEADER WITH w ui o UPLIFT SPAN 4'-6" OR CONT. PLYWOOD ROOF Q Z Q ¢ � z o E MORE. SHEATHING PER NAILING 0 O a SCHEDULE OR OPT. 2x4 p BLOCKING PERP. TO EA. pC, Q a N -' 2x DOWNFRAME TO c W w N DOOR AS REQ'D VALLEY TRUSS NAILED Lu Z O U TO TRUSS BELOW @ 24 O.C. W/ (2) 16d NAILS TYP. W 2x BLOCKING W/ (3) 12d TOE NAILED @ EA. END N W W 1/2" THREADED ROD MAIN SPAN ROOF = .� EA. SIDE OF HEADER SIMPSON META16 @ TRUSS (CENTERED w/in TOP 32" O.C. GABLE TRUSS UPLIFT CONNECTOR U) PLATE & 6" FROM JAMB TO MASONRY. AT STUDS) w/ MIN 7" WOOD WALL (SEE SCHEDULE) EMBED. INTO SLAB LOCATIONS USE MASONRY WALL ONLY REQ'D @ BRG LSTA18 OR MTS 12 @ SHOWN, SEE PLAN WALL W/ UPLIFT 32" O.C. FOR WOOD OR MASONRY ri (GE�OGABLE END AT VALLEY FRAMING o CONNECTION TO TRUSS 3/4"=1'-0" HEADER STUDS PER LV HEADER SCHEDULE 2 LO U.N.O. ON PLANS O N c.� 21-0 OZJ ATTACH JAMB STUDS V) < W PER WF08/SD4 (� co Y s= OLaO O 20 4 Lu uj p PT . BASE PLATO E � TYPICAL HEADER DETAIL 1/2"=1'-0" NOT USED SD3 JOB No. TM - 2153194 SCALE: AS INDICATED DATE: 10/11/2016 TYPICAL HEADER DETAIL 1/2"=1'-0" NOT USED SD3 NOTE: PLATE LENGTHS MUST BE AT LEAST 8'-0" LONG. TYP. PIPE OR DUCT W/ PENETRATION OF 2 ROWS 10d @ 3" O.C. MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON 2x4 STUDS PER PSPN516Z W/ (12) 16d FRAMING PLAN NAILS TYP. TOP & BOT. - DOUBLE 10d @ 3" O.C. — TOP SPLICE 2x4 BEYOND AGAINST - 48" 2x8 STUDS MSN ATTACH 2x STUDS TO - TOP PLATE W/ (4) 16d NAILS ((2) ON EA. SIDE) TYP. AT ALL EXTERIOR DOUBLE 2x4 TOP PLATE PROVIDE 2x4 ON TOP OF 2x8 TO BLOCK OUT LAP SPLICE 48" MII` TOP PLATE ATTACH W/ ATTACH PER NAILI (2) 10d NAILS O.C. PATTERN ON THIS (SOLID BLOCK W/ 2x6) DETAIL NOTES: 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES OF THE COLUMN NAIL TOP PLATE TO 2) ALL NAILS PENETRATE AT LEAST 3/4" OF THE THICKNESS OF THE LAST LAMINATION 3) FOR 5 -PLY, PROVIDE 1/4"DIA. x 5 1/2" LAG SCREWS OR EQUAL (SPACE AS SHOWN FOR 3 -PLY) BOTTOM PLATE w/ (4) 4) TOLERANCES: ALL DIMENSION TO BE HELD WITHIN +/- 1/4" 10d NAILS 1" EDGE 1 1/2" EDGE 10d x 3" COMMON - ❑X 2 1/2"z Lu a w 1 1/2" z N N _ r N N N 1. — "' 10d x 3" COMM( OVERLAP TOP PLATE 10d x 3" COMMON OPP. AT CORNER SIDE z U (DATTACH 2x STUDS TO CONDITIONS NAIL BOTTOM PLATE TO CORNER STUD TOP PLATE W/ (4) 16d PACK w/ (4) 10d NAILS U) NAILS ((2) ON EA. SIDE) TYP. AT ALL EXTERIOR 2x4 #2 SPF PLAN@ SEE TRUSS PLAN FOR 2x BRG WALL, SEE 2x8 STUDS PER MORE INFO & MORE INFO & w/ (2) 16d END NAILS IIII CONNECTION CONDITIONS STRAP IS NOT REQUIRED. �Q ++ xxx 2x12 BOX HDR w/ 2x8's FRAMING PLAN LIII ------`- U.N.O. �o 2x BLOCKING IIII 2x4 #2 SPF II II II SIMPSON LSTA24 EACH ❑ = 0 TOP SPLICE w/ (2) 16d END NAILS I I II IIII 1_JL ILL�1 PRE -ENG. ROOF BOTTOM SPLICE OVER o SPACING. MIN (2) 2x 16" O.C. MAX. _1L — �==I==IL _-------0 SEE PLAN FOR O N�--- STUD NAILS PER PLY O.C. MAX. FLOOR SYSTEM SIMPSON H3 CLIP U- 0 TOP PLATE CORNER TRANSITION - - - - -- CDO CORNER COLUMN FRAMING 12 DOUB�_------- 2xs TOP TOP PLATE TRANSITION WQ 12" O.C. PLATE PLATE 2x BOTTOM PLATE SEE PLAN F0 TYPICAL TOP PLATE SPLICE @ BRG. WALL OPENING SIZE 1 BEYOND SEE PLAN Z POST TO BEAM SIMPSON H3 CLIP 3/4"=1'-0" _- SHEATHING PER PLAN PLAN VIEW @ TOP OF POST F1 EXTERIOR SHEATHING SCHEDULE i JcnaZ�o U) TO STUDS OR BEAM w/ (4) 10d NAILS FOR 2x DBL TOP PLATE MIN. 15/32" EXP 1 SHEATHING d 00ua): cc � c CONV. FRAMED SHEATHING PER PLAN BEYOND 2 INSTALLED VERTICALLY. MEMBERS ONLY 0 NAIL SHEATHING AT FRAME WALL BOTTOM PLATE 3/8 LL z AND AT FLOOR TRUSS TOP & BOTTOM PLATES USING -IT - - - - - -------�--�- - - - FF - - - - II-- 0 v z J w_� W (1) ROW OF 8d COMMON NAILS @ 3" O.C. Q ='A'= o� NAIL SPACING 6 VV z0 z T Q NAIL AT TOP PLATE USING (2) ROWS OF 8d COMMON Z II @ 24" O.C. w/ EXT. I I II II I I W ❑ Q NAILS @ 3" O.C. I; II 11- �I- I I - II - II - II a T 0 NAIL OPENING PERIMETER w/ (2) ROWS OF 8d 1/2A, (4) 12d NAILS EACH 1/2" III - TRUSS MEMBER (TOP � w (D = COMMON NAILS @ 3" O.G. - AND BOTTOM CHORDS � m III I I I I I WALL SHEATHING o �, = Q NAIL INT. W/ 8d COMMON NAILS @ 12" O.C. & NAIL o ° III III II II I SPLICE, SEE SPLICE EDGES 6" O.C. U.N.O. PLANS A 1/2" DETAIL. MAX 1/8 III OPENING III II II II SPACE BETWEEN w w STAGGER ALL VERT. PANEL JOINTS & NAIL W/ 8d 00 (2) 2x4's (2) 2x6's TYPICAL BUILT-UP STUD COLUMN DETAIL 4 w COMMON NAILS 3" O.C. DOUBLE NAIL EDGE SPACING 2x SCAB w/ 1 O NAILS III III II PANELS @ @ 4" O.C. III 3 II I II I I J � t`6 PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO EXTERIOR SHEATHING Ir PER -ENG TRUSSES - 1-1/2"=1'-0" ROOF SHEATHING, FASTEN PER PLAN 2x4 FRAMING @ 24" O.C. MAX. PROVIDE (4)10d x3" NAILS AT JOINT 10d x 3" COMMC OPP. SIDE (2) 2x8's (2) 2x COLUMN 2 1/2" EDGE 01" sc. 2�<FN Z qp� TO O z a 00 7 c C U 0 EDGE DISTANCE PE!700 I L 10dx3" INSIDE PLY NAILS NAILED AT 8" O/C STAGGERED. OUTSIDE NAILS NAILED AT 8" O/C. OUTSIDE 2x's (3+) 2x COLUMN ROOF SHEATHING, FASTEN PER PLAN 2x4 FRAMING @ 24" O.C. MAX. PROVIDE (4) 10d x 3" NAILS AT JOINT III TYP. III II II II O HEADER W/ 8d COMMON NAILS @ 3 O.C. (2) ROWS @2x SCAB III AROUND III II II II 2x STUDS BEYOND, � � TOP &BOTTOM SHEATHING SPLICE, STUD PER PLAN �- - @ 4" O.C. 10d NAILS —I \ III OPENING III II II II SEE PLAN FOR MORE < L (2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ BETWEEN EXTERIOR TRUSS CONNECTION - INFO I— O � O VERTICAL MEMBER IF GABLE END - PER -ENG TRUSSES III III II II I z SHEATHING & PER PLAN 2 FASCIA PERP 2x FASCIA SEE PLAN 3/4"=1'-0" ROOF SHEATHING, NAIL PER PLAN (2) 2x BUILT-UP COL. DOUBLE TOP PLATE SIMPSON SP4 OR SP2 2x BLOCKING W/ (2) @ EACH STUD 12d NAILS @ EACH END - PRE-ENGINEERED \)v SIMPSON LSTA30 W/ — ROOF TRUSS - SEE II (22) 10d NAILS (ALL z FRAMING PLAN FOR CORNER CONDITIONS SPACING EXTERIOR SHEATHING STRAP AROUND a SEE PLAN FOR NAIL PER PLAN TALLER STUD) w NOTE: 15/32 OR 7/16 STRUCTURAL 1 PLYWOOD / O.S.B. TO BE USED AS UPLIFT RESISTANCE: NO OTHER FASTENERS REQ'D. EXCEPT AS NOTED ON PLANS. SHEATHING SPLICE NOTE: SAME THICKNESS AND STRENGTH AXIS ORIENTATION AS WALL SHEATHING IS REQUIRED BETWEEN STUDS. EXTERIOR SHEATHING TO BE HELD UP 1/8" THUS NOT TO BEAR ON MASONRY OR CONCRETE UNLESS FELT PAPER IS PRESENT. 1/8" GAP BETWEEN SHEETS OF PLYWOOD SHOULD BE MAINTAINED CONNECTION 2x4 #2 SPF PLAN@ SEE TRUSS PLAN FOR 2x BRG WALL, SEE w_ MORE INFO & MORE INFO & w/ (2) 16d END NAILS IIII CONNECTION II II II STRAP IS NOT REQUIRED. �Q ++ xxx 2x12 BOX HDR w/ 2x8's II II LIII TOP & BOT., 2x8 TO U.N.O. �o 2x BLOCKING IIII 2x4 #2 SPF II II II SIMPSON LSTA24 EACH ❑ = 0 STUD w/ (2) 16d END NAILS I I II IIII 1_JL ILL�1 PRE -ENG. ROOF �U- o SPACING. MIN (2) 2x 16" O.C. MAX. _1L — �==I==IL _-------0 SEE PLAN FOR O N�--- J/WRSECTION @ DOUBLE BEARING NAILS PER PLY O.C. MAX. FLOOR SYSTEM SIMPSON H3 CLIP U- 0 C�1 - - - - -- CDO CORNER COLUMN FRAMING 12 w �Ql WQ 12" O.C. CUT TO FIT 2x BOTTOM PLATE SEE PLAN HTS20 CLIP FROM OPENING SIZE 1 BEYOND SEE PLAN Z POST TO BEAM SIMPSON H3 CLIP SHEATHING DIAGRAM _- SHEATHING PER PLAN PLAN VIEW @ TOP OF POST F1 EXTERIOR SHEATHING SCHEDULE i JcnaZ�o U) SEE PLAN 3/4"=1'-0" ROOF SHEATHING, NAIL PER PLAN (2) 2x BUILT-UP COL. DOUBLE TOP PLATE SIMPSON SP4 OR SP2 2x BLOCKING W/ (2) @ EACH STUD 12d NAILS @ EACH END - PRE-ENGINEERED \)v SIMPSON LSTA30 W/ — ROOF TRUSS - SEE II (22) 10d NAILS (ALL z FRAMING PLAN FOR CORNER CONDITIONS SPACING EXTERIOR SHEATHING STRAP AROUND a SEE PLAN FOR NAIL PER PLAN TALLER STUD) w NOTE: 15/32 OR 7/16 STRUCTURAL 1 PLYWOOD / O.S.B. TO BE USED AS UPLIFT RESISTANCE: NO OTHER FASTENERS REQ'D. EXCEPT AS NOTED ON PLANS. SHEATHING SPLICE NOTE: SAME THICKNESS AND STRENGTH AXIS ORIENTATION AS WALL SHEATHING IS REQUIRED BETWEEN STUDS. EXTERIOR SHEATHING TO BE HELD UP 1/8" THUS NOT TO BEAR ON MASONRY OR CONCRETE UNLESS FELT PAPER IS PRESENT. 1/8" GAP BETWEEN SHEETS OF PLYWOOD SHOULD BE MAINTAINED CONNECTION 2x4 #2 SPF PLAN@ SEE TRUSS PLAN FOR 2x BRG WALL, SEE SHEATHING PER MORE INFO & MORE INFO & w/ (2) 16d END NAILS PLAN FOR STUD SIZE & CONNECTION CONNECTION EACH END STRAP IS NOT REQUIRED. SPACING. MIN (2) 2x ++ xxx 2x12 BOX HDR w/ 2x8's UNDER GIRDER TRUSS TO GABLE END STUDS w TOP & BOT., 2x8 TO U.N.O. (2) 1/4" X 3'/z" SIMPS. SDS 2x BLOCKING @ 24" O.C. w/ EXT. 2x4 #2 SPF @ 6" O.C. 2x12 AT SIMPSON LSTA24 EACH BLOCKING @ 24" O.C. WALL TO PRECAST STUD w/ (2) 16d END NAILS LINTEL w/ (2)ROWS OF 2x BRG WALL, SEE PRE -ENG. ROOF PLAN FOR STUD SIZE & TRUSS PER PLAN SPACING. MIN (2) 2x 16" O.C. MAX. UNDER GIRDER TRUSS xxxx SEE PLAN FOR U.N.O. CONNECTION J/WRSECTION @ DOUBLE BEARING 3/4"=1 '-0" (2) 2x TOP PLATE BLOCKING f GYPSUM WALLBOARD _ x LAN JOINT, MAX. 1/8" GAP CMU WALL PER PLAN (2) 8d TOE NAILS TO TRUSS CONNECTION (2) 8d TOE NAILS NAILING PER SCHEDULE 2x4 BLOCKING PLACED FLATWISE (2) 16d NAILS EACH END SHEATHING SPLICE DETAIL TE: CONTRACTOR TO TAKE CARE AND NOT OVER DRIVE NAILS. ILS ARE OVERDRIVEN, THE ENTIRE SHEET OF SHEATHING IS TO MOVED AND REPLACED. IF MORE THAN 50% OF THE SHEATHING ERDRIVEN, CONTACT EOR FOR REVIEW OF EXTERIOR STUDS LEDGER PER PLAN TO LEDGER 2x4 PT LEDGER W/ 2x4 LEDGER W/ (2) 16d 1/4" x4" TAPCONS @ 12" 2x FRAME WALL PER NAILS @ 16" O.C. O.C. PLAN TSEELEV. FOR SEE ELEV. FOR . SIZE O.H. SIZE CONDITION @ CMU WALL CONDITION @ FRAME WALL TYPICAL SCAB OVERHANG 3/4"=1'-0" SEE FLOOR FLAN FOR TRUSS FOR MORE INFO MORE BRG. WALL INFO LINTELS LINTELS a4 LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PL 2x6 #2 SYP P.T. CONT. 2x6 #2 SYP P.T. CONT. (2) 2x TOP PLATE ATTACH 2x TO I I BUILT-UP W/ (2) ROWS OF 10d NAILS STAGGERED @ 8" O.C. WF 1 STEP @BEARING FRAME WALL 3/4"=1'-0" /-- 2x6 SYP #2 LEDGER. TO 2x4 #2 SPF PLAN@ SEE TRUSS PLAN FOR SEE TRUSS PLAN FOR BLOCKING @ 24" O.C. SHEATHING PER MORE INFO & MORE INFO & w/ (2) 16d END NAILS 5/8" THREADED ROD w/ CONNECTION CONNECTION EACH END STRAP IS NOT REQUIRED. ++ xxx 2x12 BOX HDR w/ 2x8's 4'-0" MAX. TO GABLE END STUDS w TOP & BOT., 2x8 TO 2x8 #2 SPF VERTICAL (2) 1/4" X 3'/z" SIMPS. SDS 2x12 w/ 10d X 3" NAILS @ 24" O.C. w/ EXT. 2x4 #2 SPF @ 6" O.C. 2x12 AT SHEATHING PER BLOCKING @ 24" O.C. WALL TO PRECAST NAILING SCHEDULE & w/ (2) 16d END NAILS LINTEL w/ (2)ROWS OF + ++ + (4) 12d ,NAILS EACH EACH END 1/4" x 4" TAPCONS @ 2x4 #2 SYP P.T. @ EA. TRUSS MEMBER SYP #2 LEDGER w/ 1/4" 16" O.C. MAX. TRUSS w/ (4) 12d NAILS 2x8 w/ (2) 10d NAILS @ xxxx STAGGERED TRANSOM BETWEEN INTO TRUSS & (3) 12.d EACH VERTICAL TOENAILS INTO OTHER - TRANSOM BETWEEN SEE WALL CLIP DETAIL 4 SEE FLOOR FLAN FOR TRUSS FOR MORE INFO MORE BRG. WALL INFO LINTELS LINTELS a4 LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PL 2x6 #2 SYP P.T. CONT. 2x6 #2 SYP P.T. CONT. (2) 2x TOP PLATE ATTACH 2x TO I I BUILT-UP W/ (2) ROWS OF 10d NAILS STAGGERED @ 8" O.C. WF 1 STEP @BEARING FRAME WALL 3/4"=1'-0" /-- 2x6 SYP #2 LEDGER. TO w/ (2) 1/4" x 3 1/2" w/ (2) 1/4" x 3 1/2" TAPCONS @ 12" O.C. TAPCONS @ 12" O.C. SPACED EVENLY SPACED EVENLY VERTICALLY VERTICALLY 2x6 2x8 w/ (2) 10d NAILS @ 2x8 w/ (2) 10d NAILS @ POCKET SGD 3" O.C. TO EA, 2x6 POCKET SGD -- - - EACH VERTICAL POCKET SGD ATTACHMENT BY VERTICAL ATTACHMENT BY ATTACHMENT BY BUILDER BUILDER BUILDER S01 HEADER @ POCKET SLIDER w/ TRANSOM SO2 HEADER @ POCKET SLIDER w/ TRANSOM S03 HEADER @ POCKET SLIDER 1/2"=11-0" 1/2"=V-0" LEDGER @ LOW ROOF SEE TRUSS PLAN FOR MORE INFO & CONNECTION l� 2x8 #2 SPF VERTICAL BEAM INTO LONG SPAN AS INDICATED ON BEAM PLAN@ O.C. MAX.; STUDS w/ (2) 1/4" X 4'/2" SHEATHING PER SCHEDULE. IF BUCKET IS INSTALLED THE SHORT SPAN 5/8" THREADED ROD w/ SIMPS. SDS SCREWS @ _ STRAP IS NOT REQUIRED. 16" O.C. MAX.; w/ (2) 1/4" X 3'/Z" SIMPS. 4'-0" MAX. TO GABLE END STUDS w EXT. BEAM PER PLAN PT POST PER PLAN EXTERIOR WALL/TRUSS (2) 1/4" X 3'/z" SIMPS. SDS SDS SCREWS @ 16" FASCIA PER II SCREWS @ 16" O.C. O.C. MAX.; SO4 HEADER @ POCKET SLID COMMUNITY SPECS MAX.; LAP BEAM PLYS AND 2X4 SYP #2 OR PLAN FOR ADDITIONAL SYP #2 LEDGER w/ 1/4" TO MASONRY w/ 2x6 PT NAIL AS SHOWN (5) 10d INFO x 2 3/4" TAPCONS @12" ROOF TRUSSES @ 24" SIDE VIEW @ BASE OF POST SYP #2 LEDGER w/ (2) NAILS PER PLY O.C. MAX. SIMPSON H3 CLIP 1/4" x 2 3/4" TAPCONS AT C�1 EXT. BEAM PER PLAN SHINGLE ONLY CDO CORNER COLUMN FRAMING 12 (SDO1 TYPICAL SHED ROOF DETAIL �Ql WQ 12" O.C. oQo� SEE PLAN HTS20 CLIP FROM Z POST TO BEAM SIMPSON H3 CLIP _- SHEATHING PER PLAN PLAN VIEW @ TOP OF POST 2x4 SYP #2 LEDGER. -7 JcnaZ�o U) TO STUDS OR BEAM w/ (4) 10d NAILS FOR PT POST PER PLAN (2) 1/4" X 4'h" SIMPS. d 00ua): cc � c CONV. FRAMED ABU POST BASE PER SDS SCREWS 16" MEMBERS ONLY w/ (2) 1/4" x 3 1/2" w/ (2) 1/4" x 3 1/2" TAPCONS @ 12" O.C. TAPCONS @ 12" O.C. SPACED EVENLY SPACED EVENLY VERTICALLY VERTICALLY 2x6 2x8 w/ (2) 10d NAILS @ 2x8 w/ (2) 10d NAILS @ POCKET SGD 3" O.C. TO EA, 2x6 POCKET SGD -- - - EACH VERTICAL POCKET SGD ATTACHMENT BY VERTICAL ATTACHMENT BY ATTACHMENT BY BUILDER BUILDER BUILDER S01 HEADER @ POCKET SLIDER w/ TRANSOM SO2 HEADER @ POCKET SLIDER w/ TRANSOM S03 HEADER @ POCKET SLIDER 1/2"=11-0" 1/2"=V-0" LEDGER @ LOW ROOF SEE TRUSS PLAN FOR MORE INFO & CONNECTION l� 2x8 #2 SPF VERTICAL H u PLAN@ O.C. MAX.; SHEATHING PER 5/8" THREADED ROD w/ TO GABLE END STUDS _ (4) 12d NAILS EACH NUT SET IN ADHESIVE w/ (2) 1/4" X 3'/Z" SIMPS. 4'-0" MAX. 2x8 w/ (2) 1 O NAILS @ EACH VERTICAL SDS SCREWS @ 16" FASCIA PER II BUILDER O.C. MAX.; SO4 HEADER @ POCKET SLID COMMUNITY SPECS SEE FOUNDATION TO MASONRY w/ 2x4 PT 2X4 SYP #2 OR PLAN FOR ADDITIONAL SYP #2 LEDGER w/ 1/4" PRE-ENGINEERED _u� 3 INFO x 2 3/4" TAPCONS @12" ROOF TRUSSES @ 24" SIDE VIEW @ BASE OF POST O.C. O.C. MAX. SIMPSON H3 CLIP DESIGNED FOR C�1 SHINGLE ONLY CDO CORNER COLUMN FRAMING OZS (SDO1 TYPICAL SHED ROOF DETAIL w/ (2) 1/4" x 3 1/2" w/ (2) 1/4" x 3 1/2" TAPCONS @ 12" O.C. TAPCONS @ 12" O.C. SPACED EVENLY SPACED EVENLY VERTICALLY VERTICALLY 2x6 2x8 w/ (2) 10d NAILS @ 2x8 w/ (2) 10d NAILS @ POCKET SGD 3" O.C. TO EA, 2x6 POCKET SGD -- - - EACH VERTICAL POCKET SGD ATTACHMENT BY VERTICAL ATTACHMENT BY ATTACHMENT BY BUILDER BUILDER BUILDER S01 HEADER @ POCKET SLIDER w/ TRANSOM SO2 HEADER @ POCKET SLIDER w/ TRANSOM S03 HEADER @ POCKET SLIDER 1/2"=11-0" 1/2"=V-0" LEDGER @ LOW ROOF SEE TRUSS PLAN FOR MORE INFO & CONNECTION l� 2x8 #2 SPF VERTICAL H u @ 24" O.G. w/ EXT. vA LINTEL PER PLAN SHEATHING PER NAILING SCHEDULE & (4) 12d NAILS EACH TRUSS MEMBER 2x8 w/ (2) 1 O NAILS @ EACH VERTICAL POCKET SGD ATTACHMENT BY BUILDER SO4 HEADER @ POCKET SLID 10d x 3" OPP. SIDE WCE PER Q 0 to y�tltllllYj �— rn ,� •',�'y Y o p 1 j� z Z ROOF SHEATHING, ac ,Q + U p U FASTEN PER PLAN o o; C) ui J z •'~ Z D m LL •. .• e 't 11111110 2x4 #2 SYP CONT. w/ (2) 16d COMMON NAILS �ll EA. STUD OR TRUSS V 0 MEMBER, TYP. (MAX. c1n 24" O.C.). IF MASONRY, [� � 0/ M w/SMIN. 2" EMBED. @S U Jlyl��3 24" O.C. J 0 M MM z TRUSS PER PLAN F� a o O mu U tI 4 WOOD/MASONRY z �G WALL OR TRUSS, SEE PLAN (TRUSS SHOWN) Q a o0 SD4 ...J O Lu W J n �gv 06 W C�1 1 1' OZS N w:p z�-' E Q z Ui LL U �Ql WQ oQo� Z _ O JcnaZ�o U) d 00ua): cc � c — 2x8 TO UNDER SIDE OF z p z ¢ cin z z E ROOF SHEATHING 02 = °u;a 04 0 W Q w 04 Lu z0 z 2x8 #2 SPF VERTICAL 51 Z @ 24" O.C. w/ EXT. W 2 SHEATHING PER NAILING SCHEDULE & ♦ ^ v W (4) 12d NAILS EACH TRUSS MEMBER (TOP = AND BOTTOM CHORDS � m ALONG W/ WEBBING) s 2x8 w/ (2) 10d NAILS @ EACH VERTICAL ER o Le � 11 A Z cv p� Z 0 � tea-! 0LO00 C4 Z U O J A Lu 5 >. Q Q I3 CL H2H STRUCTURAL ENG: BED DRAFTING: -STRUCT: TNT QC CHECK: CC JOB No. TM - 2153194 SCALE: AS INDICATED DATE. 10/11/2016 SD4 4 f