Loading...
276, 278, 280 ,282 Maybeck Ct 10-2098 (a)ABV. ABOVE A/C AIR COMPRESSOR ADJ. ADJUSTABLE AHU AIR HANDLER ALT ALTERNATE AMP. AMPERAGE BD. BOARD BLK BLOCK BLK'G. BLOCKING C.L. CENTER LINE CABT. CABINET CLG. CEILING CLR. CLEAR CONC. CONCRETE CPT. CARPET C.T. CERAMIC TILE C.J. CONTROL JOINT CMU CONCRETE MASONRY N.I.C. UNIT D. DRYER DBL. DOUBLE DIA. DIAMETER DIM. DIMENSION DISP. DISPOSAL DP. DEEP DR. DOOR D.S. DOWNSPOUT DTL. DETAIL D.W. DISHWASHER EA. EACH ELEV. ELEVATION ENG'D. ENGINEERED EQ. EQUAL EXH. EXHAUST EXT. EXTERIOR F.G. FIXED GLASS FIN. FINISH FLR. FLOOR FLR'G FLOORING FLUOR. FLUORESCENT FR. DR. FRENCH DOOR FTG. FOOTING - ABBREVIATIONS GA. GAUGE G.F.I. GROUND -FAULT CIRCUIT RIS INTERRUPTER GL. GLASS GYP. BD. GYPSUM BOARD H.C. HOLLOW CORE HDR. HEADER HT. HEIGHT INSUL INSULATION INT. INTERIOR LAM. LAMINATED LAV. LAVATORY LUM. LUMINOUS M.C. MEDICINE CABINET MFR. MANUFACTURER MIN. MINIMUM MTD. MOUNTED MTL. METAL N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE O.C. ON CENTER P.L. PROPERTY LINE P.B. PUSH BUTTON PH. PHONE PLYWD. PLYWOOD PR. PAIR PT PRESSURE TREATED R. RISER RAD. RADIUS R/A RETURN AIR GRILL REF. REFRIDGERATOR REV. REVERSE a � M/1 0 M/1 HOMES SE RM. ROOM R.O. ROUGH OPENING RIS ROD AND SHELF S.C. SOLID CORE S.D. SMOKE DETECTOR S.H. SINGLE HUNG SH SHELF SHTHG. SHEATHING SHWR. SHOWER SIM. SIMILAR SGD. SLIDING GLASS STD. STANDARD TEMP. TEMPERED GLASS THK. THICK T.O.C. TOP OF CURB T.O.P. TOP OF PLATE T.O.S. TOP OF SLAB TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VP. VAPOR PROOF W. WASHER W/ WITH WD. WOOD WDW. WINDOW W/H WATER HEATER W.I. WROUGHT IRON W.P. WEATHER PROOF HOMES SUBDIVISION: RIVERVIEW RVICE CORP. LOT #: RV 125-128 MODEL: RV - 4 UNIT - MISC. AREA WINDOWS CODE DESCRIPTION 0016 SINGLE HUNG - BLOCK 0026 SINGLE HUNG - FRAME 0030 FIXED GLASS - FRAME 151; 5TY. LIVING 623 0021 SLIDING GLASS DOOR - BLOCK 623 2644 1 VMFLG VERTICAL - BLOCK 1 VMFIN VERTICAL - FRAME q46 DOORS CODE DESCRIPTION 7 SINGLE/DOUBLE INSWING/OUTSWING (2068, 2468, 2668, 2868, 6068) 156q 8'xT GARAGE DOOR ENTRY 40 MISC. AREA BUILDIN6 TYPE: 2 STORY TOHNHOU5E Sheet Title TAB Cover Sheet UAT UNIT UNIT UNAIT REQUIRED PROVIDED DOTAL 151; 5TY. LIVING 623 134 664 623 2644 2nd STY. LIVING 946 q01 816 q46 3b0q TOTAL LIVING 156q 1635 1480 156q 6253 ENTRY 40 51 65 40 1616 GARAGE 5614 230 242 5q4 1660 LANAI 41 NA NA 41 82 TOTAL U.R. 224ZI 1916 1181 2244 5IgI PATIO NA 1 361 36 NA 12 CODE SUMMARY APPLICABLE GODE5 I. FLORIDA BUILDING CODE 2001 - RESIDENTIAL 2001 4 2008 SUPPLEMENTS 2. FLORIDA BUILDING CODE 2004 - BUILDIN6; CHAPTER 13 - AGGE551BILITY 3. NATIONAL ELEGTRIGAL CODE, NFPA 10, 2005 EDITION 4. FLORIDA FIRE PREVENTION CODE - 2001 EDITION BUILDIN6 TYPE: 2 STORY TOHNHOU5E Sheet Title GON5TRUGTION TYPE: UNPROTEGTED,UN5PRINKLED Cover Sheet FIRE PROTECTION RATING REQUIREMENTS: Elevations 2 REQUIRED PROVIDED I. PARTY AND FIRE HALL5 2 HR. 2 HR. 2. INTERIOR BEARING HALLS 0 0 3. INTERIOR NON BEARING PARTITIONS PER 105.1.2 0 0 4. GOLUMN5 0 0 5. BEAMS 6 RDERS 775=5 AND ARGHES 0 0 6. FLOOR/GEILIN6 GON5TRUGTION Foundation Plan 1. ROOF / GEILIN6 GON5TRUGTION 0 0 8. EXTERIOR BEARING HALLS 1st Block Plan HORIZONTAL SEPARATION: (PARRALLEL HALLS) 2nd Block Plan 0 ft. to 6 ft (0 % OPENIN65) 1 (0%) N/A (0%) OVER 6 ft O O q. EXTERIOR NON BEARING HALLS Separation Walls HORIZONTAL SEPARATION: (PARRALLEL HALLS) Detail Sheet 0 ft. to 6 ft (0 % OPENING -5) 1 (0%) N/A (0% OVER 6 ft 0 0 ELEV SHEET LIST Sheet List Table Sheet Number Sheet Title 0 Cover Sheet 1 Elevations 2 Elevations Side -Rear 3 1st Floor Plan 4 2nd Floor Plan 5 Cross Sections 6 1st Electrical Plan 7 2nd Electrical Plan 8 Foundation Plan g Plumbing 10 1st Block Plan 11 2nd Block Plan 12 1st Framing Plan 13 2nd Framing Plan 14 Separation Walls D1 Detail Sheet D2 Detail Sheet D3 Detail Sheet LATEST REVISION DATE TO MASTER: 08-19-10 Z a) 75 -00 w c� .� w cn Cn O _ w c C O co 00 U 0? co .0 co cd LLI LO .L U C"S)w^ as w Z; 8 = F=- C3 Q = V .S2O 1 LL_ p m C �- Q � 00 O -Q r rn L0 CD N � r W W' W = w Z � 0 d- U I.L � w O C/)J (/) DO NOT 5GALE PRNT51 G4)N5TRUGTION SHALL BE PER IWIGATED 0I4EN610% ONLY, ANY 015GREPENGIE5 TO BE REPORTED TO M/1 HOMES FOR GLARF!GATION! t 0 of ## M11 ORLANDO Z 0, o o Q OM C O co 00 U 0? co .0 co cd LLI LO .L U C"S)w^ as w Z; 8 = F=- C3 Q = V .S2O 1 LL_ p m C �- Q � 00 O -Q r rn L0 CD N � r W W' W = w Z � 0 d- U I.L � w O C/)J (/) DO NOT 5GALE PRNT51 G4)N5TRUGTION SHALL BE PER IWIGATED 0I4EN610% ONLY, ANY 015GREPENGIE5 TO BE REPORTED TO M/1 HOMES FOR GLARF!GATION! t 0 of ## M11 ORLANDO Z Q OM w OO � Z O E— C O co 00 U 0? co .0 co cd LLI LO .L U C"S)w^ as w Z; 8 = F=- C3 Q = V .S2O 1 LL_ p m C �- Q � 00 O -Q r rn L0 CD N � r W W' W = w Z � 0 d- U I.L � w O C/)J (/) DO NOT 5GALE PRNT51 G4)N5TRUGTION SHALL BE PER IWIGATED 0I4EN610% ONLY, ANY 015GREPENGIE5 TO BE REPORTED TO M/1 HOMES FOR GLARF!GATION! t 0 of ## M11 ORLANDO I I E6RE55 38.5 cn _o ql'-0" 23'-0° 22'_6' .221_6" 23'-0" b'-3° ,. 5'-3Ih" 11 8'-5' q'-2" 13'-4" 13'-4" 5'-3112" b'-3" ROOF BEL 5040HR EGRESS M.BAT _ ' o II ° _ � II � II 2bba s 2465 ° " 3 ¢" m ¢ EWALL 2bba I I a'-0' GL6. HT. 2466 s 2665 I I a'-0" GLC. HT. ° 2465 668 I M. BATH _ _ _ `� MASTER° ' 2. M.BATH MASTER = = M. BATH Y-2' GARPET v CARPET ° Y-2" Q (� a.- ■ WA2xb ° ■ _Q --- 2 4'-0' m ------ _ - ------- -- - - 8'-0' GL6. HT. 8'-O' GL6. HT. D. -------------- - MASTER q'_qN 4'-0' _ ! 2 " 4'-5" 12'-11/2' q�" - MASTER CARPET = w2aLL ;; BATH 2 5 LINEN 5H 1 ii 2xbKA CARPET WALL ((2465 � 2465 ; i m 3'-¢2468 ( i 2465 { 3'-2" AG DUCT ' ° s - - ■ , 11 AG DUCT 3 -2 CHASE TO 1iL15T -CHASTO 5TY �r �I 5H3050 ` E6RE55 385 m 0 _____ ___= STY. 1 ------------ - ___�_ _____ SFI3050 12'-I 1i2' S LINEN SH jj ° n, i 5 LINEN 5H 2665 = 12'-I 1/2" 5H3050 EGRESS 11 - 5 LINEN 5H E6RE55 _ _ - 355 5'-O' r - � 1 tj f � 2bba 2bba _ i I{ ( F�Fk-j 11 DN (11) I 11 I 2xb 2xb I 1 I J (� ° _ - - - 18 5'-11/2' '1 ° 111 KALL- J I f060 R15ER5° �2bba`v L2bba L�L� A� ��--1 1 ii ON (11) I { -___�___�J� Ill 11 13' 2°I{HANDRAILbbb -2' RI M, b -7r _ L_ 26b � 2x6 WALL W! �- �L - �! AHU tlo VINs 42"H. ROOF ROOF �, _ _ _ _ _ _ - - - - - - _ = r- - -n 2x4 _ OPEN TO BELOW n �- BELOW ° - - - - - AHU I I I ° ° BA H 2 L - 0 ° 6b I {{ - 2bba 0 � � HND I 5065 Y-111 - ATH2 - 0�__�, ___12" BATH2 ::�tl, '-5 12" 5'-0" m L "P0 EN i LO m 5'-0" 5'-51I -I 2 1'-1 1/2° 5 112 '-b Ill 3 -2 r 4Y5 I! = 3' -II - If2 LI I 2bba"26bb L_ ` � � '� I I AM ° 42"H. 1 I - - - - - 42'H. b'-0" GL6. HT. ■ - - - - 2x4 2x4 ° 2bba 2bba _ ■ ON (11) RAILING RAILLIIN6 RDI'y 5 o BED 2 ----__-____ ________ RISERS WALL - - - HANDRAIL 266a r2b HANDRAIL - CARPET _ _ `~ - - - " - -`V - - - - - - - - - 2668 1150bb 50ba 50b8 _ 2bba 2665 = 2bba---------- ----------- ZGHA5E G DUCT `N TO- _-_-_- - 15T 51Y. - --- 506a 50bu v 65 ■ 5065 v 1�-bl 5065 ■ 10 -Ili ° 1014" 10'-10" ° " 5H3050 - E6RE% 8'-0" GL6. HT. 5'-0' GL6. HT. Sas 5' 0° GL6. HT. - ° BED 2 BED 3 m m 11'0' - BED 3 _ - CARPET CARPET I I' -o" N ROOF BELOW CARPET ° 5'-0" GL6. HT. 5'-0" GL6. HT.N ■ EXTEND SHAFT EXTEND 5HAFT ° 5'-0" GLC. HT. S' o°GL6. HT. BED 3 BED 2 - OVEWALL INTO WALL INTO = BED 2 BED 3 RHANG TO OVERHANG TOO CARPET CARPET ALI6N ABV. AL16N ABV. CARPET CARPET SOFFIT ■ 5OFFIT ■ 5040HR DBL -5H3050 51-13050 EGRE55 EGRE55 E6RE55 ■ 31.1 385 I 5H3o5o 0W 50050EH6R0 E6RE55 EGRES 38.5 I I 3a.5 LINE OF 15T 5TORY 385 LINE OF151 5TSTORY LINE OF 15T STORY EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL -- ROOF BELOW ROOF BELOW 20'-3" '-b 12" l0'-1" 5' -II" II' 5 I II' -0 112" 5'-5' I/2" 20-3" '-b 1/2" LEXINGTON II TRENTONPRINCETON LEXINGTON II �,C„ UNIT "B„ UNIT "A„ UNIT "X UNIT 2nd STY. FLOOR PLAN 1/4" = 1'-0' nMr- Unl1D DATF-n rt/It„" 1-1Ur- 0r-TAi:-) iA1KIT CUKI1TWIKIt=, WA5HER 08-19-10 TAB 3040 24" VOID 5TAGK 3040 PLACE DBL. UG 504M DBL. WALL STUD ADJ. TO 3040 5040HR 134 OF BELOW SPACING_ PRE -FAB 45X32 FIXED 834 51g8 P, PRE-FA45X32 q4b q01 E�5 816 81b TEMP F PRE -FAB 45X32 EGRESS 6221 TOTAL LIVING 1180 1 SHOWER BASE 385 1480 1480 1 355 SHO BASE 11425 31.1 40 51 30.5 BASE 31.1 5040HR 51 40 ° GARAGE 238 230 230 242 242 230 238 1650 LANAI 41 NA ■ NA E6RE55 NA 41 82 TOTAL U.R. 20gq Iglb ° 1181 1181 Iqlb 20gq 13520 PATIO NA 36 36 36 36 36 NA 180 " .. ' .. II -II 1/2 24 5'-0" 4'5' -0.. 0 0 0 ROOF BEL 5040HR EGRESS M.BAT _ ' o II ° _ � II � II 2bba s 2465 ° " 3 ¢" m ¢ EWALL 2bba I I a'-0' GL6. HT. 2466 s 2665 I I a'-0" GLC. HT. ° 2465 668 I M. BATH _ _ _ `� MASTER° ' 2. M.BATH MASTER = = M. BATH Y-2' GARPET v CARPET ° Y-2" Q (� a.- ■ WA2xb ° ■ _Q --- 2 4'-0' m ------ _ - ------- -- - - 8'-0' GL6. HT. 8'-O' GL6. HT. D. -------------- - MASTER q'_qN 4'-0' _ ! 2 " 4'-5" 12'-11/2' q�" - MASTER CARPET = w2aLL ;; BATH 2 5 LINEN 5H 1 ii 2xbKA CARPET WALL ((2465 � 2465 ; i m 3'-¢2468 ( i 2465 { 3'-2" AG DUCT ' ° s - - ■ , 11 AG DUCT 3 -2 CHASE TO 1iL15T -CHASTO 5TY �r �I 5H3050 ` E6RE55 385 m 0 _____ ___= STY. 1 ------------ - ___�_ _____ SFI3050 12'-I 1i2' S LINEN SH jj ° n, i 5 LINEN 5H 2665 = 12'-I 1/2" 5H3050 EGRESS 11 - 5 LINEN 5H E6RE55 _ _ - 355 5'-O' r - � 1 tj f � 2bba 2bba _ i I{ ( F�Fk-j 11 DN (11) I 11 I 2xb 2xb I 1 I J (� ° _ - - - 18 5'-11/2' '1 ° 111 KALL- J I f060 R15ER5° �2bba`v L2bba L�L� A� ��--1 1 ii ON (11) I { -___�___�J� Ill 11 13' 2°I{HANDRAILbbb -2' RI M, b -7r _ L_ 26b � 2x6 WALL W! �- �L - �! AHU tlo VINs 42"H. ROOF ROOF �, _ _ _ _ _ _ - - - - - - _ = r- - -n 2x4 _ OPEN TO BELOW n �- BELOW ° - - - - - AHU I I I ° ° BA H 2 L - 0 ° 6b I {{ - 2bba 0 � � HND I 5065 Y-111 - ATH2 - 0�__�, ___12" BATH2 ::�tl, '-5 12" 5'-0" m L "P0 EN i LO m 5'-0" 5'-51I -I 2 1'-1 1/2° 5 112 '-b Ill 3 -2 r 4Y5 I! = 3' -II - If2 LI I 2bba"26bb L_ ` � � '� I I AM ° 42"H. 1 I - - - - - 42'H. b'-0" GL6. HT. ■ - - - - 2x4 2x4 ° 2bba 2bba _ ■ ON (11) RAILING RAILLIIN6 RDI'y 5 o BED 2 ----__-____ ________ RISERS WALL - - - HANDRAIL 266a r2b HANDRAIL - CARPET _ _ `~ - - - " - -`V - - - - - - - - - 2668 1150bb 50ba 50b8 _ 2bba 2665 = 2bba---------- ----------- ZGHA5E G DUCT `N TO- _-_-_- - 15T 51Y. - --- 506a 50bu v 65 ■ 5065 v 1�-bl 5065 ■ 10 -Ili ° 1014" 10'-10" ° " 5H3050 - E6RE% 8'-0" GL6. HT. 5'-0' GL6. HT. Sas 5' 0° GL6. HT. - ° BED 2 BED 3 m m 11'0' - BED 3 _ - CARPET CARPET I I' -o" N ROOF BELOW CARPET ° 5'-0" GL6. HT. 5'-0" GL6. HT.N ■ EXTEND SHAFT EXTEND 5HAFT ° 5'-0" GLC. HT. S' o°GL6. HT. BED 3 BED 2 - OVEWALL INTO WALL INTO = BED 2 BED 3 RHANG TO OVERHANG TOO CARPET CARPET ALI6N ABV. AL16N ABV. CARPET CARPET SOFFIT ■ 5OFFIT ■ 5040HR DBL -5H3050 51-13050 EGRE55 EGRE55 E6RE55 ■ 31.1 385 I 5H3o5o 0W 50050EH6R0 E6RE55 EGRES 38.5 I I 3a.5 LINE OF 15T 5TORY 385 LINE OF151 5TSTORY LINE OF 15T STORY EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL -- ROOF BELOW ROOF BELOW 20'-3" '-b 12" l0'-1" 5' -II" II' 5 I II' -0 112" 5'-5' I/2" 20-3" '-b 1/2" LEXINGTON II TRENTONPRINCETON LEXINGTON II �,C„ UNIT "B„ UNIT "A„ UNIT "X UNIT 2nd STY. FLOOR PLAN 1/4" = 1'-0' nMr- Unl1D DATF-n rt/It„" 1-1Ur- 0r-TAi:-) iA1KIT CUKI1TWIKIt=, 7/8" EXT. PORTLAND GEMENT I/2" x 8°L THREADED ROD W/ I" RND. HASHER PLASTER ON PAPER BACKED 5ET W EPDXY FILLED 5/8" DIA. DRILLED S EXPANDED METAL LATH ON TYVEK GLEANED HOLE (4" MIN. EMBED INTO GMU WALL) BOLT INSTALLATION NOTES: 3" MIN. ED6E DiSrANcE • BOLTS SHALL NOT BE INSTALLED IN A HORIZONTAL LINE ON OPPOSITE SIDES OF SEPARATION WALL -STAGGER 4" VERTICALLY FROM BOLT ON OPPOSITE SIDE OF WALL TYP. CMU TO FRAME WALL DETAIL AT SEPARATION WALL- 5GALE: 3"=I' -O" WDW.ROUGH OPNG.NOTE 36 718.x 63 WIDTH x HEIGHT (IN INCHES) WALL LEGEND. INDICATE5 2x4 BEARING WALL W/ 6-A11GK TIE 5Y5TEM HOLDDOM5 FROM TOP OF ® 15T STORY BLOCK WALL TO 5EGOND 5TORY TOP PLATE. 5EE 5HEET 11 FOR ADDL. INFORMATION ® INDICATE5 20 BEARING WALL ABOVE LAM. BEAM. PROVIDE 5TRAPPIN6 PER DETAIL #5 ON 5HT.12 ® INDIGATE5 2 -HR FIRE 5EPARATION WALL BTWN. UNIT5. 5EPARATION WALL- GONTINUU5 FROM TOP OF FIR5T 5TORY 5 -AB TO UNDERSIDE OF 5EGOND 5TORY ROOF DEGKIN6. NO ELEGTRIGAL, PLUMBING; MECHANICAL, OR OTHER BLD6.5ERVIGE SHALL BE WITHIN OR PENETRATE THE SEPARATION WALL. REFER TO 5EPARATION WALL DETAILH FOR ADDITIONAL INFORMATION. AREA WA5HER 08-19-10 TAB PLUMB'GBOX 24" VOID 5TAGK UGIT PLACE DBL. UG UNIT DBL. WALL STUD ADJ. TO STUD VENT PIPE 134 STUD SPACING_ DETAIL @ WASHER. 7/8" EXT. PORTLAND GEMENT I/2" x 8°L THREADED ROD W/ I" RND. HASHER PLASTER ON PAPER BACKED 5ET W EPDXY FILLED 5/8" DIA. DRILLED S EXPANDED METAL LATH ON TYVEK GLEANED HOLE (4" MIN. EMBED INTO GMU WALL) BOLT INSTALLATION NOTES: 3" MIN. ED6E DiSrANcE • BOLTS SHALL NOT BE INSTALLED IN A HORIZONTAL LINE ON OPPOSITE SIDES OF SEPARATION WALL -STAGGER 4" VERTICALLY FROM BOLT ON OPPOSITE SIDE OF WALL TYP. CMU TO FRAME WALL DETAIL AT SEPARATION WALL- 5GALE: 3"=I' -O" WDW.ROUGH OPNG.NOTE 36 718.x 63 WIDTH x HEIGHT (IN INCHES) WALL LEGEND. INDICATE5 2x4 BEARING WALL W/ 6-A11GK TIE 5Y5TEM HOLDDOM5 FROM TOP OF ® 15T STORY BLOCK WALL TO 5EGOND 5TORY TOP PLATE. 5EE 5HEET 11 FOR ADDL. INFORMATION ® INDICATE5 20 BEARING WALL ABOVE LAM. BEAM. PROVIDE 5TRAPPIN6 PER DETAIL #5 ON 5HT.12 ® INDIGATE5 2 -HR FIRE 5EPARATION WALL BTWN. UNIT5. 5EPARATION WALL- GONTINUU5 FROM TOP OF FIR5T 5TORY 5 -AB TO UNDERSIDE OF 5EGOND 5TORY ROOF DEGKIN6. NO ELEGTRIGAL, PLUMBING; MECHANICAL, OR OTHER BLD6.5ERVIGE SHALL BE WITHIN OR PENETRATE THE SEPARATION WALL. REFER TO 5EPARATION WALL DETAILH FOR ADDITIONAL INFORMATION. AREA DATE TO MASTER: 08-19-10 TAB Z UNAIT UGIT UGIT UNIT UG UNIT UNAIT OTAL 15t 5TY. LIVING 834 134 134 664 664 134 834 51g8 2nd 5TY. LIVING q4b q01 q01 816 81b g01 q4b 6221 TOTAL LIVING 1180 1 1635 1635 1480 1480 1 1635 1180 11425 ENTRY 40 51 51 b5 65 51 40 363 GARAGE 238 230 230 242 242 230 238 1650 LANAI 41 NA NA NA NA NA 41 82 TOTAL U.R. 20gq Iglb Iqlb 1181 1181 Iqlb 20gq 13520 PATIO NA 36 36 36 36 36 NA 180 SECOND STORY PLAN NOTES: L DRYER VENT BOX - VENT THRU ROOF. 2. 24" W. MALL CAVITY, VOID OF 5TUD5, FOR WA5HER BOX AND 5TAGK. 3. 12" W. WALL CAVITY, VOID OF 5TUD5, FOR SHOWER VALVE AND/OR HEAD. 4. HARZARDOU5 GLAZING LOCATION, IN5TALL TEMPERED 6LA55 IN ALL SHOWER ENGL05URE5 AND/OR WINDOW5. 5. DO NOT SCALE PRINT5! GON5TRUGTION TO BE FROM CALCULATED DIMEN5ION5 ONLY. ANY 0I5GREPENGIE5 TO BE REPORTED TO M/I HOMES FOR CLARIFICATION. ALL FRAME WALL5 ARE DRAWN AND DIMENSIONED TO BE 3 1/2" WIDE UNLE55 OTHERWISE NOTED. b. PROVIDE DRAIN PAN BELOW EACH WA5HER. DRAIN LINE TO EXTERIOR. 1. PROVIDE 2x4 AT 24" O.G. VERT. LADDER BLOGKINO AT INTER5EGTION OF INTERIOR TO EXTERIOR FRAME WALL5 FOR INSTALLATION OF INSULATION. LATEST REVISION DATE TO MASTER: 08-19-10 Z o0 Q Lu U_ z\ tY Lu C/) t!3 7 Ll! 0 O C 7�� o C p co U o°Do Lu �CU �COw� _LLI _U CC = Q aW=o �m�� �+V JZNM O Q �-i i LL W N LL C � Q � C)C) O N 1 � _ N o LLJ J. Q > W � C � o Z > > o Lu 0 U) J CI) DO NOT SCALE PRINTS! CONSTRUCTION SHALL BE PER INDICATED DIMENSIONS ONLY, ANY DISCREPENCIES TO BE REPORTED TO MA HOMES FOR CLARIFICATION! e F4of14 M/I ORLANDO Z Q ULL1� W 0 O �z o DC � 0 C p co U o°Do Lu �CU �COw� _LLI _U CC = Q aW=o �m�� �+V JZNM O Q �-i i LL W N LL C � Q � C)C) O N 1 � _ N o LLJ J. Q > W � C � o Z > > o Lu 0 U) J CI) DO NOT SCALE PRINTS! CONSTRUCTION SHALL BE PER INDICATED DIMENSIONS ONLY, ANY DISCREPENCIES TO BE REPORTED TO MA HOMES FOR CLARIFICATION! e F4of14 M/I ORLANDO j FIN. 4' 0 O 2-#5 BARS I'-4" GONT.ON GHAIR5 TYP" 1 -STY. SLAB EDGE O O O 345 BARS DONT. ON CHAIRS INT, FRAME BRG° WALL FTG. FIN. 4' 0 O O O O 3-#5 BARS 1'-10° CONT. ON GHAIR5 2 TYP.2-STY. SLAB EDGE VERIFY w/ DOOR MANJF. �LOPE— • • DRIVE (3) #5'5 GM. HAY ON GHAIR5 Ib" o SLAB EDGE FTG. AT GARAGE DOOR OPNG. GURB WIDTH A5 5TATED ON PLAN5 VARIES . VARIE5 VARIES LANAI 5LAB v OR ENTRY — 4 FH ARS PAVER5 O OON 3-#5 BARS I'-10"RS DONT. ON GHAIR5 RAISED CURB FTG. 3 AT GARAGE EXT. WALLS SLOPE 0 O 1 #5 CONT. 8. 7 PATIO/ENTRY ei AD CnP-C 11/2' CURB VARIES VARIE5 VARIES z_ #5 BAR _ z 4" T F 3 AT 24" O.G. 4 3 4-#5 BARS 2'-0" DONT. ON GHAIR5 3A RAISED CURB FTG. sa INT. BLK. WALL FT BTWN. GARAGE STEP DN. BTWN. GARAGE INT. WALLS ADJ. UNIT INTERIOR WALL 3-#5 BARS CONT. ON GHAIR5 G. AT SLAB VARIE5 O 1 #5 CONT. $ INT. NON-BRG, SLAB STEP DN. FTG. 412 S BRG. WALL VARIE5 4 O O O 345 BARS DONT. ON GHAIR5 4 INT. BRG. WALL FTG._ AT SLAB STEP DN. 8" GMU DATE TO MASTER: WALL z #5 BAR AT EA. REINF. FIN. AT 24" O.G. GRADE Qw2o V M rn �+ JZNccl) 1 4-#5 BAR5 LL' i ILLI U 2'-0" DONT. ON GHAIR5 s TYPICAL FTG. @ U) 0 INT. SEPARATION O I a l a 1 1 A 412 S BRG. WALL VARIE5 4 O O O 345 BARS DONT. ON GHAIR5 4 INT. BRG. WALL FTG._ AT SLAB STEP DN. 8" GMU DATE TO MASTER: WALL #5 BAR DOLL Z AT EA. REINF. FIN. FILLED GELL GRADE Qw2o V M rn �+ JZNccl) 1 o0 LL' i ILLI U w 2LLI U) 0 TOP FT6. -I'-I I/2' A.F.F. O CZ=� �z E A74 CN �z > 4CONT. GONG. DONT. 2'-0" FT6. sw� STEM WALL DETAIL AT ENTRY W IYPIGAL ED6E z O O PIPING 7 PIPE (6" DIA. MAX.) SLEEVE (DIA. LARGER THAN PIPE) TYP. PIPE THRU FTG. DETAIL AS REQ'D. STEM � MONO MONO STEM SND 5TEM WALL FTG. DEPTH OF REBAR 2'-1° INTO MONOL!THIG PAVER5 ON MONOLITHIC 5LAB 5LAB E06E 50IL GEffK/ EDGE TO MATCH 5AND BASE BOT. OF STEM WALL FTG. FIN. oz ' 6RADE 45" 5TEM HALL 2'-b" j Q FT6.REBAR15 to BRICK PAVER DETAIL xx STEM WALL FTG. TO MONO SLAB EDGE TRANSITION FOUNDATION NOTES: I. 0 INDIGATE5 FILLED CELL Wl 300 F51 GROUT H/ 145 REBAR UNLE55 NOTED OTHERHI5E. 2. DO NOT 5GALE PRINTS! GON5TRUGT FROM CALCULATED DIMEN510N5 ONLY. ANY 015GREPANGIE5 TO BE REPORTED TO M!1 HOME5 FOR GLARIFIGATION. 3. REFER TO PLUMBING PLAN FOR FIXTURE, PLUMBING WALL, AND GONGUIT UNDER 5LAB LOGATION5. 4. AG PA05 TO BE 12" MIN. GLEARANGE FROM 5LA13 EDGE. 5. T.O.F. = TOP OF FOOTING SLAB PLAN 1/4" = 1'-O" LATEST REVISION DATE TO MASTER: C F— 08-19-10 Z w 'R in 0 Cts = F- cl)L Q= C Qw2o V M rn �+ JZNccl) 6 o0 LL' wN� d ILLI U w 2LLI U) 0 O O CZ=� �z E A74 C O a"". CO C F— CU m Z w 'R in 0 Cts = F- cl)L Q= C Qw2o V M rn �+ JZNccl) 6 LL. Q wN� d Um W O o0O N a� �z � O CN �z > J Q -I W O �2 z> C O a"". CO C F— CU m W w 'R in 0 Cts = F- cl)L Q= C Qw2o V M rn �+ JZNccl) 6 LL. � wN� d O N a� _ Q — � O CN LLJ > J Q -I W �2 z> W � 1 > W H O C/) J CIS DO NOT SCALE PRINTS! CONSTRUCTION SHALL BE PER INDICATED DIMENSIONS ONLY, ANY DISCREPENCIES TO BE REPORTED TO MII HOMES FOR CLARIFICATION! 8 of 14 M/I ORLANDO Roof Girder Connector Schedule GONNEGTIN6 EA. 2ND 5TY. 5TU D TO TOP PLATE GENTER 5TRAP ON BOT. OF TOP PLATE # OF NAIL5 REQUIRED AT TOP 4 BOT CHORD (q)IOd x 1-I/2" Max. Max. TRU55 H/ (4)I6d NAILS Plan PARRALLEL TO HALL Connector RIM BOARD 112" FROM Uplift Gravi GMU HALL Mark Manuf. Model No. Qty. Load Load Fasteners / Remarks 1 SIMPSON MTS12 2 1720 I6" DP. FLOOR FIRST (2) TRU55 BAYS - OR (14) 10d x 1-112" EA. 2 SIMPSON LGT2 1 1785 FILL ALL NAIL HOLES (14) 16d SINKERS AT WALL F O 0 O Z > 16" DP. LAM. BEAM PER PLAN (16) 16d SINKERS AT GIRDER 3 SIMPSON MGT1 — — 3330 — (1) 5/8"" DIAM. BOLT & (22)-10d \1 / SETBACK FACE OF RIM BOARD 112" FROM HDU4 1 3600 W (10) - 1/411 x 2 112" SDS SCREWS 4 SIMPSON HU28 1 575 2450 (6) - TITEN 1/4" x 2 3/4" TO CMU TO BE REPORTED TO NUI HOMES FOR CLARIFICATION! GONG. BLOCK4HALLT (4) 10d x 1 1/2" TO TRUSS 5 SIMPSON HU28-2 1 1085 4350 TITEN 1/4" x 2 3/4" TO CMU 12 TRUSSES PARRALLEL TO WALL (6) 10d TO TRUSS 6 SIMPSON HU410 1 1810 5085 (18) - TITEN 1/4" x 2 3/4" TO CMU (10) 10d TO TRUSS 7 SIMPSON LGUM410 1 3575 9620 (8) - TITEN HD 3/8" x 4'" TO CMU 8 1/411 x 2 1/2" SDS SCREWS 8 SIMPSON HTT16 1 3480 (1) 5/8" DIAM. BOLT TO_CMU — OR — — -- --___(18)16dTOSTUD _ MSTCM40 1 3300 (8) - TITEN 1/4" x 2 3/4" TO CMU 22 SINKERS NKERS TO STUD 13" DP. FLAT GIRDER TRU55 OR 16" PP. FLOOR TRU55 7 GONG. BLOCK HALL CONNECT HANGER TO GMU HALL H/ PROVIDE HD. SHIMS AS (12) 1/4"x2 3/4" 5IMP50N REOV. TO FILL GAP BTHN. "TITEN" 5GREH5 HAN6ER AND TRU55 5IMP50N HU26 OR HU26-2 HANGER W (b) 10d NAILS TO TRU55 TRUSS TO CMU FALL 12 HANGER CONNECTION 3 PLY 16 FLAT GIRDER lT 51HP50N "L6T3-5D52.5" (21)I6d SINKERS TO GOLUMT (12) SD5 I/4"x2 I/ 5GREH5 TO 61RDE 3.5"A a 5IMP50N "HTT16" HOLPDOHN H/ 5/8" THREADED ROD TO 5LAB-5ET IN EPDXY FILLED HOLE H/ 5" MIN. EMBED FILL ALL NAIL HOLES GIRDER TRUSS TO 9 COLUMN TO SLAB 12 �j ('(1AIAIC!'TI(lAl GMU SEPARATION HALL BTHN. UNITS GONNEGTOR VARIE5-5EE PLAN FOR INFORMATION 16" DP. FLAT 61PDER TRU55 OR lb" DP. FLOOR TRS PROVIDE W. SHIMS AS �:T '/ REOV, TO FILL 6AP BTHN. HANGER AND TRU55 51HP50N "HU46" HANGER H/ (6) 10d NAILS TO TRU55 I GONG. BLOGK WALL CONNEGT HANGER TO GMU WALL H/ (12) 1/4"x2 3/4" 5IMP50N "TITEN" 5GREH5 10 TRUSS TO CMU WALL 12 HANGER CONNECTION /-5IMP50N 15TAI2" OR QUIGK-TIE 1512" FLAT 5TRAP DE_rv-i. U04 i EIC D i "r UN DU 1. OF i num UK DEAM - hV 5" MIN. Lmbu) FILL ALL NAIL HOLE5 8 2ND STY FRAME WALL TO GIRDER 12 OR BEAM STRAP CONNECTION LVL BEAM ORSIMP50N "HTT16' HOLPPOHN GIRDER TRU55 IH/ 5/8" /{REAPED ROD TO PER PLAN BLK. HALL-5ET IN EPDXY FILLED HOLE H/ 5" MIN. EMBED FILL ALL NAIL HOLE5 GONG. BLOCK HALL BEAM 1 GIRDER TRUSS TO CMU WALL �2 STRAP CONNECTION 2 or 3 PLY 16" DR FLATGONG. BLOCK 61RDER TRU55k(6HE)" HALL CONNECT H.AN6ER TO CMU HALL H/ )114"x2-112" 5IMP50N "TITEN 2 PLY-SIMPSON L M2b- H VI'l / HANGER H/ (6) 51)5- 1/41x2 I/2" 5GREH5 TO TRU55 (2435# MAX UPLIFT) 3 PLY-51MP50N LHJM28-3 HANGER Hl (6) 5D5- 1/4"x2 112" 56REH5 TO TRUSS (3515 # MAX UPLIFT) FLAT GIRDER TRUSS 7 TO CMU WALL 12 uAal(_M ('()K1 1C(%T10K1 GONNEGTIN6 EA. 2ND 5TY. 5TU D TO TOP PLATE GENTER 5TRAP ON BOT. OF TOP PLATE # OF NAIL5 REQUIRED AT TOP 4 BOT CHORD (q)IOd x 1-I/2" OR LAM. BEAM PER PLAN (6)I0d x TRU55 H/ (4)I6d NAILS (4)IOd xI-1/2" PARRALLEL TO HALL U RIM BOARD 112" FROM BLOCK WALL CONNECTION &H. OPENING PER PLAN GMU HALL Lu o 2" MIN. DIMENSION TRU55 OR BEAM 112" DBL. STRAP AT EA_ 51DE OF OP%. TO 5TRAP FROM OR ANCHOR A5 NOTED AT FROM FACE OF BLOCK GMU HALL 48" O.C. MAX. IN SIMPSON "HETA2O" ANCHOR LJL I6" DP. FLOOR FIRST (2) TRU55 BAYS - OR AT 24" O.G. MAX. - PROVIDE 4" DIMENSION TO SOLID 2x4 VERT. BLK-r7. BTHN. TRU55 STRAP FROM FACE TOP 4 BOT CHORDS FOR NAILING OF BLK. WALL FILL ALL NAIL HOLES 6" DP. GABLE END FLR. TRU55 OR F O 0 O Z > 16" DP. LAM. BEAM PER PLAN W GIRDER TRU55 OR 1HP50N "HTTIb" H1 LVL BEAM PER PLAN/5/b"THREADEPROD 5IMP50N "L5TAI2" OR GJIGK-TIE "L512" FLAT 5TRAP GONNEGTIN6 EA. 2ND 5TY. 5TUD TO 61RDER TRU55OR BLK. HALL-5ET IN OXY FILLED HOLE DE_rv-i. U04 i EIC D i "r UN DU 1. OF i num UK DEAM - hV 5" MIN. Lmbu) FILL ALL NAIL HOLE5 8 2ND STY FRAME WALL TO GIRDER 12 OR BEAM STRAP CONNECTION LVL BEAM ORSIMP50N "HTT16' HOLPPOHN GIRDER TRU55 IH/ 5/8" /{REAPED ROD TO PER PLAN BLK. HALL-5ET IN EPDXY FILLED HOLE H/ 5" MIN. EMBED FILL ALL NAIL HOLE5 GONG. BLOCK HALL BEAM 1 GIRDER TRUSS TO CMU WALL �2 STRAP CONNECTION 2 or 3 PLY 16" DR FLATGONG. BLOCK 61RDER TRU55k(6HE)" HALL CONNECT H.AN6ER TO CMU HALL H/ )114"x2-112" 5IMP50N "TITEN 2 PLY-SIMPSON L M2b- H VI'l / HANGER H/ (6) 51)5- 1/41x2 I/2" 5GREH5 TO TRU55 (2435# MAX UPLIFT) 3 PLY-51MP50N LHJM28-3 HANGER Hl (6) 5D5- 1/4"x2 112" 56REH5 TO TRUSS (3515 # MAX UPLIFT) FLAT GIRDER TRUSS 7 TO CMU WALL 12 uAal(_M ('()K1 1C(%T10K1 FLOOR TRU55E5 AT 24" O.G. MAX. 6ABLE END FLR. TRU55 # OF NAIL5 REQUIRED AT TOP 4 BOT CHORD (q)IOd x 1-I/2" OR LAM. BEAM PER PLAN (6)I0d x TRU55 H/ (4)I6d NAILS (4)IOd xI-1/2" PARRALLEL TO HALL U RIM BOARD 112" FROM BLOCK WALL CONNECTION SETBACK FACE OF GMU HALL Lu o 2" MIN. DIMENSION TRU55 OR BEAM 112" AT EA. FLOOR TRU55/61RDER TO 5TRAP FROM OR ANCHOR A5 NOTED AT FROM FACE OF BLOCK GMU HALL 48" O.C. MAX. IN SIMPSON "HETA2O" ANCHOR LJL I6" DP. FLOOR FIRST (2) TRU55 BAYS - OR AT 24" O.G. MAX. - PROVIDE 4" DIMENSION TO SOLID 2x4 VERT. BLK-r7. BTHN. TRU55 STRAP FROM FACE TOP 4 BOT CHORDS FOR NAILING OF BLK. WALL FILL ALL NAIL HOLES FLOOR TRU55E5 AT 24" O.G. MAX. 2x4 CONT. RIM BOARD # OF NAIL5 REQUIRED AT TOP 4 BOT CHORD (q)IOd x 1-I/2" CONNECT TO EA. FLR. (6)I0d x TRU55 H/ (4)I6d NAILS (4)IOd xI-1/2" SETBACK FACE OF U RIM BOARD 112" FROM BLOCK WALL CONNECTION FACE OF BLOCK GMU HALL Lu o 2" MIN. DIMENSION 5IMP50N "HETA20" ANCHOR AT EA. FLOOR TRU55/61RDER TO 5TRAP FROM OR ANCHOR A5 NOTED AT FACE OF BLK. WALL LOCATION- FILL ALL HOLES PRE-ENGINEERED ROOF TRU55 OR GONV. FRAMED RAFTER 5IMP50N "HETA20" STRAP AT EA. TRU55 - NAILS PER 5GHE ULE "HETA20" STRAP NAILING 5GHEDULE UPLIFT VALUE # OF NAIL5 REQUIRED 1810 (q)IOd x 1-I/2" 1200 (6)I0d x 800 (4)IOd xI-1/2" TYPICAL FLR. TRUSS I BEAM TYPICAL FLR. TRUSS I BEAM 1/ I L 1--_GMU�� 12 PARALLEL TO CMU WALL12 PERPENDICULAR TO CMU WALL TYPICAL TRUSS TO 1101 SFT STRAP CONNECTinn1 HDI ICT CTDAD !'(1AIAIC(`TI(lAI �� ... ............ .....,.._,._,,.., *UNLE55 OTHERH15E NOTED ON THE PLAN I6" DP. FLOOR TRUSSES H/ MID SPAN BRE -FILL ALL NAIL HOLES GONG. 51MP50H "HETA20" BLK. AT EA. FLR. TRU55- HALL FILL ALL NAIL HOLES 5 FLR. TRUSS TO CMU WALL 12 STRAP CONNECTION MID SPAN BEARING CONDITION 1st STY. FRAMING PLAN 1/4" = 1'-0" FRAMING PLAN NOTES: I. PERMANENT OR TEMPORARY BRAGIN6 OF TRU55E5 PER HIB91. ANY ADDITIONAL TRU55 5RAGIN6 REQUIRED HILL BE DETERMINED BY TRU55 EN6INEER ON 516NED AND 5EALED TRU55 OIAG-RAM5. 2. ALL TRI155 TO TRU55 GONNEGTOR5 TO BE SUPPLIED BY TRU55 MANU FAGTURER. 3.INDIGATE5 #2 5YP OR BETTER 2x4 BLK6. AT 48" O.G. BTHN. TRU55 BOT. GHORD5 ® H/ (2)-Ibd GOMMON5 TOE -NAILED EA. 510E. (TYP. AT 15T (4) TRU55 BAYS AT ALL 6ABLE EN05 UNLE55 OTHERW15E 5HOHN ON THE PLAN) 4. ALL OVERHAN65 TO BE 12" UNLE55 OTHERH15E NOTED ON FRAMING PLAN OR ELEVATION5. 5. PROVIDE MIN. (2)-I0d TOE -NAILED COMMONS AT EA. TRU55 BEARING BOTTOM GHORO TO TOP PLATE AT ALL FRAME BR6. HALLS. (ADDS 150 LB5 UPLIFT ( APAGITY TO 5TRAP GAPAGITY) b. ALL INTERIOR FRAME BEARING HALLS SUPPORT 6RAVITY LOADS ONLY (NO UPLIFT GONNEGTOR5 REOV) 1. FLOOR TRU55 TOP GHORD BEARIN6 CONDITION ON 13" PP. 61RDER TRU55 OR BEAM. 8.15T 5TY. OR 20 5TY. PLUMBING WALL, TOILET, OR FLOOR FITTIN6. q. PROVIDE AG DUCT RUN THRU FLOOR TRU55E5 - MAXIMIZE OPENIN6 AT GENTER OF SPAN IO.PROVIDE 2x12 LEDGER (BOTTOM AT TRUSS 5R6. HT.) W (10) IOd NAIL5 AT EA, VERT. 5TUO. 11. PROVIDE 20 LEPC-ER A5 REOV. FOR FLOOR DEGK NAILII6. 12. ALL 61RDEiZS SHORN 51N6LE PLY. FOR CLARITY - 5� TRU55 ENGINEERING FOR REQUIRED NUMBER of PLIES. DESIGN LOADS: DEAD - 17 PSF. (T.C. - 7 PSF.), (B.C. - 10 PSF.) BOTTOM CHORD NON -CONCURRENT LIVE LOAD - 10 PSF. WIND SPEED - 120 MPHJ3 SEC. GUST EXPOSURE CATEGORY - "C" - ENCLOSED BUILDING TYPE. FLOOR LOADS: LIVE - 40 PSF. DEAD - 15 PSF (T.C. - 10 PSF.), (B.C. 5 PSF.) LATEST REVISION DATE TO MASTER: 08-19-10 o0 W U Er W to zz C/) LuO _ r - m CO .L Z �CwL cc W o 0 F- Z co a= ¢W=o U vm13,� J Z N M BLOCK WALL CONNECTION UNLE55 OTHERH15E NOTED ON THE PLAN 12 Q Lu o Opp ' UNLE55 OTHERH15E NOTED ON THE PLAN x UPLIFT LOAD REQUIREMENTS OBTAINED FROM SEALED O - EN61NEERIN6 DRAHIN65 FROM TRU55 MANUF. 2x4 X-BRAGIN6 AT 2x4 BOX FRAME AT 48" O.G. MAX. Hf 1 � 00O 48" O.C. MAX. IN 05B 5HEATHIN6 EA. 51DE (CONNECT TO LJL I6" DP. FLOOR FIRST (2) TRU55 BAYS - OR 2x4 W 8d NAILS AT 6" OL) AT FIRST 0) TRU55E5 PER PLAN CONNECT EA. END TRU55 BAYS -CONNECT EA. CORNER H/ W H/ (2)IOd TOENAILS (2)IOd TOENAIL5 6" DP. GABLE END FLR. TRU55 OR F O 0 O Z > 16" DP. LAM. BEAM PER PLAN W \1 / SETBACK FACE OF RIM BOARD 112" FROM 0 W O co J cl) DO NOT SCALE PRINTS! FACE OF BLOCK PER INDICATED DIMENSIONS ONLY, ANY DISCREPENCIES TO BE REPORTED TO NUI HOMES FOR CLARIFICATION! GONG. BLOCK4HALLT 24 O.G. MAX. - PROVIDE SOLID BRACING BTWN. FROM FACE OF BK.BOT CHRORDS FOR NAAIII_If 6 FILL°L L FLR. TRUSSES NAIL HOLES s PERIMETER WALL DETAIL 12 TRUSSES PARRALLEL TO WALL 1st STY. FRAMING PLAN 1/4" = 1'-0" FRAMING PLAN NOTES: I. PERMANENT OR TEMPORARY BRAGIN6 OF TRU55E5 PER HIB91. ANY ADDITIONAL TRU55 5RAGIN6 REQUIRED HILL BE DETERMINED BY TRU55 EN6INEER ON 516NED AND 5EALED TRU55 OIAG-RAM5. 2. ALL TRI155 TO TRU55 GONNEGTOR5 TO BE SUPPLIED BY TRU55 MANU FAGTURER. 3.INDIGATE5 #2 5YP OR BETTER 2x4 BLK6. AT 48" O.G. BTHN. TRU55 BOT. GHORD5 ® H/ (2)-Ibd GOMMON5 TOE -NAILED EA. 510E. (TYP. AT 15T (4) TRU55 BAYS AT ALL 6ABLE EN05 UNLE55 OTHERW15E 5HOHN ON THE PLAN) 4. ALL OVERHAN65 TO BE 12" UNLE55 OTHERH15E NOTED ON FRAMING PLAN OR ELEVATION5. 5. PROVIDE MIN. (2)-I0d TOE -NAILED COMMONS AT EA. TRU55 BEARING BOTTOM GHORO TO TOP PLATE AT ALL FRAME BR6. HALLS. (ADDS 150 LB5 UPLIFT ( APAGITY TO 5TRAP GAPAGITY) b. ALL INTERIOR FRAME BEARING HALLS SUPPORT 6RAVITY LOADS ONLY (NO UPLIFT GONNEGTOR5 REOV) 1. FLOOR TRU55 TOP GHORD BEARIN6 CONDITION ON 13" PP. 61RDER TRU55 OR BEAM. 8.15T 5TY. OR 20 5TY. PLUMBING WALL, TOILET, OR FLOOR FITTIN6. q. PROVIDE AG DUCT RUN THRU FLOOR TRU55E5 - MAXIMIZE OPENIN6 AT GENTER OF SPAN IO.PROVIDE 2x12 LEDGER (BOTTOM AT TRUSS 5R6. HT.) W (10) IOd NAIL5 AT EA, VERT. 5TUO. 11. PROVIDE 20 LEPC-ER A5 REOV. FOR FLOOR DEGK NAILII6. 12. ALL 61RDEiZS SHORN 51N6LE PLY. FOR CLARITY - 5� TRU55 ENGINEERING FOR REQUIRED NUMBER of PLIES. DESIGN LOADS: DEAD - 17 PSF. (T.C. - 7 PSF.), (B.C. - 10 PSF.) BOTTOM CHORD NON -CONCURRENT LIVE LOAD - 10 PSF. WIND SPEED - 120 MPHJ3 SEC. GUST EXPOSURE CATEGORY - "C" - ENCLOSED BUILDING TYPE. FLOOR LOADS: LIVE - 40 PSF. DEAD - 15 PSF (T.C. - 10 PSF.), (B.C. 5 PSF.) LATEST REVISION DATE TO MASTER: 08-19-10 o0 W U Er W to zz C/) LuO _ C O r - m CO .L Z �CwL cc W o 0 F- Z co a= ¢W=o U vm13,� J Z N M o Q ��� ILL. Q Lu o Opp w O w 0 1 � 00O -Ln T- LJL r J Q �// W F O 0 O Z > C O r - m CO .L U �CwL cc W o 0 F- Z co a= ¢W=o U vm13,� J Z N M o Q ��� ILL. C_ Lu o O 1 � 00O -Ln r J Q �// W F O Z > W \1 / 0 W O co J cl) DO NOT SCALE PRINTS! CONSTRUCTION SHALL BE PER INDICATED DIMENSIONS ONLY, ANY DISCREPENCIES TO BE REPORTED TO NUI HOMES FOR CLARIFICATION! n 12 of 14 M/I ORLANDO DBL. 2x P.T BLOGKIN6 (2)12d NAILS VERT. REINF. GONG. AT b" O.G. FILLED CELL W1 145 $AR- n 112' EXP. BOLT AT 24" O.G. VERT. (2 3/4" EMBED) W/ 2"50. WASHER REIN. FILLED7F., BLOCK G0I I 51MP50N "5P2" AT EA. STUD AT EXTERIOR WALLS USE 5PH4 (AT GON( . BLK. INTERIOR BEARING WALL5) WALL PER TYP. WALL 5EGTION I I ATTACH EXT. SHEATHING TO 5TUD5 / PLATES PER 5TRUGTURAL NOTES VERT. REINF. GONG. FILLED GELL W/ 145 BAR AT EXT. FRAME WALL TO BLOCK WALL, PROVIDE 2x P.T. W/ 1/2' EXP. BOLT AT 24' O.G. VERT. (4' EMBED) W/ 2" 50. WA5HER5 PROVIDE 1112" EDGE D15TANGE FOR BOLTS a I I N 51MP50N '51?2" AT EA. STUD AT EXTERIOR WALLS (05E 5PH4 AT INTERIOR BEARING WALL5) II �_ TOP OF 5LAB I 8.. — — J EXT. FRAME WALL TO BLOCK WALL CONNECTION DETAIL APPLICABLE TO ALL EXTERIOR FRAME WALL5 ONLY UNLE55 OTHERWI5E NOTED ON FLOOR PLAN 118" ASS> TER PAPER BACK LATH BUILDIN6 WRAP (TYVEK) WALL 5HEATHIN6 PEEL AND 5TIGK MEMBRAFLASHINE ALUMINUM WINDOW FRAME SET IN DONT. BED OF SEALANT EXTERIOR WINDOW HEAD SCALE: 2" - P-0" ALUMItlUM WINDOW FRAME SET IN DONT. BED OF SEALANT PEEL AND STICK MEEMMBRFLASNE BUILDIN6 WRAP (TYVEK) I Ll WALL 5HEATHIN6 PAPER BAGK LATH l/8" GEMENT PLASTER uL EXTERIOR WINDOW SILL 5GALE: 2" - 1'-0" T N r 0 r ALUMINUM WINDOW FRAME SET IN DONT. BED OF SEALANT PEEL AND 5TIGK MEMBRANE FLA5HIN6 WALL SHEA '-1/81 GEMENT PLASTER PAPER BACK LATH BUILDING WRAP (TYVEK) EXTERIOR WINDOW JAMB 5GALE: 2" - 1'-0" TYVEK OVER 'G' PEEL AND STICK FLA5HIN6 AND WINDOW FLANGE TAPE OVER GUT IN TYVEK C r , -------------- ------ 3/4' DIA. x 6' DP. HOLE BI _ I 1 I I I I I I FOR #5 BAR DOWEL SET IN I I I I I 1 E_ START B 5TRIP5 HERE EDGE OF WINDOW 00 O APPLY PEEL AND 5TIGK FLASHING MEMBRANE IN ORDER STARTING AT BOTTO OF WINDOW AND OVERLAPPING A5 INDICATED 5TRUGTURAL ROOF GROUT SOLID AT DONT. 2x4 W/ Q PEEL AND STICK DETAIL BLOCK CELL DETAIL PROVIDE SOLID 2x4 BLK6. BTWN. 20 "T" OR "L' 5TRONCBAGK AT GABLE 3/4' DIA. x 6' DP. HOLE TOP/130T. RAILS FOR 50LID OVERHANG5 OVER 12"-GONNEGT Wl FOR #5 BAR DOWEL SET IN c— � � a LU 03 EPDXY ADHESIVE 00 O FA5GIA MATERIAL TO BE 5TRUGTURAL ROOF GROUT SOLID AT DONT. 2x4 W/ TOP OF BLK. WALL TOP OF DELL 2-12d NAILS COL. REMAINDER AT T' O.G. GONG. FILLED REINF. SAWCUT APPROX. 2x4 OUTLOOKER5 AT 24" O.G. Wl w 0.145 DIAx3 L. POWDER (5)1/4"x21/4' MASONRY 5GREW5 TOP GOUR5E PER (3)12d TOE -NAILED TO TRU55 TOP ACTUATED FASTENERS- PLACE TO BLOCK WALL AND (00d j TALLER THAN V-0" BLK6. ALONG 51H OF GABLE END TYP. HALL SEGTION OPENING WALLjE LOGATION5 AND TYPES FLP, TRUSSES l/lb" 05B 5HEATHIN6 OVER GABLE END I 112" DRYWALL OVER Ix2 P.T. (MIN) AT 24" VENTED SOFFIT AT EA. 2x4 TO 2x4 JOINT �Q�s O.G. (MAX) , ""IN HOLE TO BGLEANED FADE OF 5HEATHIN6 FLUSH W/ BLK. WALL i FREBAR5PONOTES: PRIOR TO ( , , ENER6Y GALGULATION FOR R -VALUE 3000 P51 DISPEN51N6 ADHESIVE TYP. WALL 5EGTION i GONG. FILLED --EPDXY ADHESIVE TO "HETA20" STRAP 5PEGIFIED TEXTURED GEMENT FINISH OVER GELL W/ #5 HIGH 5TREN&TH TYPE CONTROL / EXPAN51ON JOINT Bxbxlb GONG. BLOGKAND REBAR --REBAR DOWEL MUST PAPER BACK LATH i IB' WIDE PEEL Q 5TIGK BE GLEAN AND OIL FREE MEMBRANE OR #15 FELT 2x4 BLK6. AT 48" O.G. FROM GABLE SAiUT I° W. OPN6. IN 5AWGU BUILDING WRAP (TYVEK) WALL 5HEATHIN6 HDR Om. WALL FROM TOP TO 4APPP I) I BOTTOM GHORD5 BOTTOM FOR FULL HT. .PROX OPENING IN WALL _z IIII Hi REBAR PLACEMENT 6YP5UM GEILIN6 51MP50N "HETA20' AT ot INTO GELL-FILL SOLID EA. TRU55 VERT. OR 24" O.G. GONNEGT W/ a II CABLE END TRU55 10d NAILS AT 8' STOP 25" MIN. LAP GOUR5E - FILL H/ GONG. AND 145 O.G. OF 5LAB OF KEBABS ut BAR DONT. DONT. 20 MIN. P.T. PLATE W/ 1/2" DIA. A.B. OR 518 EXP. BOLT W/ 2 i i � z [a s►MPsoN "L5TAI2' m 3/4' DIA. x b' OR HOLE FOR #5 BAR DOWEL SET IN u, EPDXY ADHESIVE ADDED MONOLITHIG SLAB E06E REINF. FILLED BLOCK CELL DETAIL PROVIDE SOLID 2x4 BLK6. BTWN. 20 "T" OR "L' 5TRONCBAGK AT GABLE 20 LADDER FRM6. REOV. AT TOP/130T. RAILS FOR 50LID OVERHANG5 OVER 12"-GONNEGT Wl 12d NAILS AT 12" O.G. c— � � a NAILING OF STRAP 41-0" 00 O FA5GIA MATERIAL TO BE 5TRUGTURAL ROOF SHEATHING SEE DONT. 2x4 W/ PROVIDE 2x4 BLK6. BTWN. FLR \` 2-12d NAILS COL. REMAINDER AT T' O.G. TRU55- GONNEGT TO BLK. W/ (4) 51MP5ON "M5TAM24" 51RAP NU 2x4 OUTLOOKER5 AT 24" O.G. Wl w 0.145 DIAx3 L. POWDER (5)1/4"x21/4' MASONRY 5GREW5 20 5TRO%BACK IF 6ABLE TRUSS 15 (3)12d TOE -NAILED TO TRU55 TOP ACTUATED FASTENERS- PLACE TO BLOCK WALL AND (00d j TALLER THAN V-0" BLK6. ALONG 51H OF GABLE END GOMMON5 TO FLP, TRU55 a LOGATION5 AND TYPES FLP, TRUSSES l/lb" 05B 5HEATHIN6 OVER GABLE END I 112" DRYWALL OVER Ix2 P.T. (MIN) AT 24" VENTED SOFFIT AT EA. 2x4 TO 2x4 JOINT �Q�s O.G. (MAX) , Lu Lun FADE OF 5HEATHIN6 FLUSH W/ BLK. WALL i SPAN BRACING REG2'D. GONG. FILLED REINF. ( , , ENER6Y GALGULATION FOR R -VALUE TOP BLK. COURSE PER 3 TYP. WALL 5EGTION MISSED FLOOR TRUSS TO BLK. WALL STRAP PROVIDE (1) "M5TAM24" FOR EA. "HETA20" STRAP 5PEGIFIED TEXTURED GEMENT FINISH OVER METAL OR VINYL TRIM FT. BRAGI% REOV. CONTROL / EXPAN51ON JOINT Bxbxlb GONG. BLOGKAND IV GEMENT PLASTER tt PAPER BACK LATH FRM6. PLAN FOR LOGATION5-5ET STRAP 2' IB' WIDE PEEL Q 5TIGK u MEMBRANE OR #15 FELT 2x4 BLK6. AT 48" O.G. FROM GABLE FLASHING BUILDING WRAP (TYVEK) WALL 5HEATHIN6 DETAIL @CONTROL / EXPANSION JOINT 5GALE: 3" - 1'-0" 25' MIN. LAP #5 REBAR Wf 5TD. HOOK REINF. GONG. FILLED GELL #5 VERT. REBAR - - BxBxib GONG. KNOCKOUT BLK. TOP GOUR5E - FILL Wf GONG. t 145 BAR CONT. L Q tt , BLOCK WALL HT. T11 RANSITI `- 25" MIN. LAP #5 REBAR W/ 5TD. HOOK ON DETAIL 51MP50N "MT5MI6" STRAP W/ (4)1/4"x2 1/4" TAPGON5 TO BLOGK WALL AND (i)IOd n COMMONS TO TRU55 i t ROOF TRUSS � tt It t :77 Lut INSTALL ADD'L. STRAP �_ DIAGONALLY FROM EA. sy " n t OTHER FOR 51N6LE GONG. FILLED REIN. MEMBER TRUSS TOP BLK. GOUR5E PER TYP. WALL 5EGTION MISSED ROOF TRUSS TO BLK. WALL STRAP 8'-0" MAX. SPAN WO 2x8 RID6E 2x4 VERTICAL BLK6. 2xb VALLEY RAFTERS (4)lbd 2x4 COLLAR TIE IN NAILS UPPER 3RD OF ROOF HT. ---- - AT EVERY 3RD PAIR OF ------ - RAFTERS MTAP t 2x4 VERT. AT MT512 STRAP i 6-0® O.G. MAX. (ONLY STRAP 't AT SPANS > 8'-0") 20 BLK6. AT VALLEY RAFTER BRC. BTWN. TRUSSES ROOF TR 65 ROOF TRU% BELOW RAFTER HAND VALLEY FRMG. DETAIL ALTERNATE VALLEY DETAIL FROM TRU55 EN61NEER MAY BE SUBSTITUTED PROVIDED DETAIL HAS STATE OF FLORIDA LIGEN5ED STRUCTURAL EN61NEER STAMP USE (1) MT5MIb STRAP FOR UPLIFT VALUE -5 860 LBS. OR LE55 USE (2) MT5MIb STRAPS FOR UPLIFT VALUES 1120 LBS. OR LE55 UPLIFT VALUES OVER 1120 LB5. REQUIRE LETTER FROM ARGHITEGT OR ENGINEER 1/I6" OSB 5HEATHIN6 GABLE END OR FLOOR TRU55 IV GEMENT PLASTER ON PAPER BAGK LATH AIR INFILTRATION BARRIER (0E516N STANDARD: TYVEK) MID -WALL HEEP 5GREED 1/2" MIN. GEMENT PLASTER 8" GMU WALL DETAIL @ BLOCK I F 5GALE: 3" = P -O" RAME CONNECTION PRE-EN6'RED FLOOR TRUSSES AT 24' O.G. GONNEGT EA. TRJ55 BOT. GHORD W/ (2)lbd MIN. GOMMON5 TOE -NAILED TO TOP PLATE �Z 1/2" 6YPSUM BD. DBL. 2x TOP PLATE R -II INSULATION AT ALL WALLS ADJACENT TO NON -AIR GONDITIONED 5PAGE5 2x GONT. MID -WALL 13LK6. (WALLS OVER 8,'H. --PROVIDE BLK6. AT 4'-0' O.G. MAX) 112' DRYWALL 2x STUDS @ 16' O.G. #2 5PF OR BETTER 2x4 P.T. 51LL PLATE - ATTAGH W/ (2) GONG. NAILS OR (1) POWDER ACTUATED FASTENER AT 24" O.G. 3 112" MIN. GONG. SLAB (2500 P50 W/ FIBERME5H OR bxb 10/10 WWM OVER VAPOR BARRIER GLEAN GOMPAGTED�� o o E EARTH FILL THIGKEND SLAB FOOTING PER SLAB PLAN TYP. INT. BRG. WALL SECTION 5GALE: 1 112"=I' -O" A' 5' INCL. ROOF FDC -7F ROOF O.H. ROOF E06E G k ROOFO.H. O1 ZONE I - USE 8d "RIN65HANK" NAILS @ 12' O.G. (FIELD) 6" O.G. (EDGE) ZONE 2 - USE 8d "RIN65HANK" NAILS @ 6" O.G. (FIR D/EDH) O ZONE 3 - USE 8d "RIN65HANK" NAILS @ 4" O.G. (FIELD/ED6E) ROOF NAILING PATTERN NOTE: ALL PLYWOOD ROOF 5HEATHI% SHALL HAVE A "PANEL SPAN RATIN6" OF 32116. APPROVED SHINGLES MANUF. I TYPE: GERTAINTEED "LANDMARK 30 AR" GERTAINTEED 'LANDMARK 30' FLASHING: ALL ROOF AND WALL FLA5HIN6 TO BE ALUMINUM OR 6ALV. METAL MATERIAL. GONNEGT W/ 6ALV. METAL NAILS AT 24' O.G. MAX. 5HIN6LE5 (ATTAGH W/ GALV. METAL ROOFIK16 NAILS PER MANUF. INSTALLATION DETAIL5) OVER 15# FELT (2" SIDE LAP / 4" END LAP AND GAP NAILS AT 12" O.G.-EDGE, 24`0L. -FIELD) ON Ulb" SPAN RATED 5TRUGTURAL 5HEATHIN6 (SEE ROOF NAILING PATTERN) AND PRE-EN6RED ROOF TRUSSES AT 24" O.G. HIRR. STRAP AT EA. TRU55 SEE 12 ROOF PLAN PER F— Bxbxlb GONG. KNOGKOUT BLK. TOP ELEV. R-30 INSULATION GOUR5E - FILL W/ GONG. AND 145 BAR DONT. DRIP E06E1/2" 20 "T" OR "L' 5TRONCBAGK AT GABLE 20 LADDER FRM6. REOV. AT VERTICAL LONGER THAN 4b'( ONNE6T W/ OVERHANG5 OVER 12"-GONNEGT Wl 12d NAILS AT 12" O.G. c— � � a (2)12d TO TRU65 TOP GHORD 41-0" 00 O FA5GIA MATERIAL TO BE 5TRUGTURAL ROOF SHEATHING SEE DONT. 2x4 W/ ROOF NAILING PATTERN \` 2-12d NAILS COL. REMAINDER AT T' O.G. BOARD OVER 2x4/2xb C.) 2x4 OUTLOOKER5 AT 24" O.G. Wl w 5UBFA5GIA REFER TO SUBD. 7ACO 20 5TRO%BACK IF 6ABLE TRUSS 15 (3)12d TOE -NAILED TO TRU55 TOP ( j TALLER THAN V-0" GHORD I a LOGATION5 AND TYPES 2x4 DIA6. 'X"-BRAGIN5 Wl (3)12d NAILS l/lb" 05B 5HEATHIN6 OVER GABLE END I 112" DRYWALL OVER Ix2 P.T. (MIN) AT 24" VENTED SOFFIT AT EA. 2x4 TO 2x4 JOINT TRU55-GONNEGT W/ Sd NAILS AT 6" O.G.--SET O.G. (MAX) , Lu BRACING SCHEDULE FADE OF 5HEATHIN6 FLUSH W/ BLK. WALL i SPAN BRACING REG2'D. (PROVIDE I/8" SPACE BTWN. PANELS) ( , , ENER6Y GALGULATION FOR R -VALUE 6REATER THAN 20 FT. 10 (3) PAIRS AT 1/4 M. (1) 3 i FT. TO 20 FT. LE55 THAN 10 PAIR AT MID -PT. NO "EFTA° 'LTA!" i , TEXTURED GEMENT FINISH OVER FT. BRAGI% REOV. U.S.P. OR 51MP50N STRAP -SEE Bxbxlb GONG. BLOGKAND tt GONG. FILLED BLOGK CELL AS LOCATED FRM6. PLAN FOR LOGATION5-5ET STRAP 2' I i i u PER PLANS 2x4 BLK6. AT 48" O.G. FROM GABLE FROM FACE OF BLOGK AND PARALLEL TO PRECAST WN. SILL - TYP. AT STD. END BAGK 8'-0" BTWN. TRUSS HDR Om. Q Q TRU55-FILL ALL HOLES W/ NAILS BOTTOM GHORD5 _z IIII Hi I 6YP5UM GEILIN6 51MP50N "HETA20' AT ot DIAPHRAM NAILING EA. TRU55 VERT. OR 24" O.G. GONNEGT W/ a Bxbxlb GONG. KNOCKOUT BLK. TOPROOF CABLE END TRU55 10d NAILS AT 8' (14)I0d COMMONS INTO i GOUR5E - FILL H/ GONG. AND 145 O.G. SOLID 2x4 BLK6. — GLEAN GOMPAGTED ut BAR DONT. DONT. 20 MIN. P.T. PLATE W/ 1/2" DIA. A.B. OR 518 EXP. BOLT W/ 2 i i FLAT CEILING GABLE END s►MPsoN "L5TAI2' 2x4 CONT. BLK6. 50. WASHER AT 48" O.G. MAX. OR STRAP AT 24" O.G. DBL. 2x4 TOP (2)POWER-DRIVEN NAILS (51ZE MONOLITHIG SLAB E06E #5 BAR DOWEL TIED TO FTG. REBAR Ib" FOOTING PER SLAB PLAN TRU55 TO PLATE RATE TO IOd COMMON) AT I b" O.G. MIN. LOCATED PER SLAB PLAN TYP. EXT. : 11 5GALE: I/2"= I' -O" TYP. GABLE END FRAME WALL ° GABLE END "HETA20" GABLE END TRUSS DETAIL STRAP ALTERNATIVE 5GALE :1/2" =1'-0" APPROVED SHINGLES MANUF. I TYPE: GERTAINTEED "LANDMARK 30 AR" GERTAINTEED 'LANDMARK 30' FLASHING: ALL ROOF AND WALL FLA5HIN6 TO BE ALUMINUM OR 6ALV. METAL MATERIAL. GONNEGT W/ 6ALV. METAL NAILS AT 24' O.G. MAX. 5HIN6LE5 (ATTAGH W/ GALV. METAL ROOFIK16 NAILS PER MANUF. INSTALLATION DETAIL5) OVER 15# FELT (2" SIDE LAP / 4" END LAP AND GAP NAILS AT 12" O.G.-EDGE, 24`0L. -FIELD) ON Ulb" SPAN RATED 5TRUGTURAL 5HEATHIN6 (SEE ROOF NAILING PATTERN) AND PRE-EN6RED ROOF TRUSSES AT 24" O.G. HIRR. STRAP AT EA. TRU55 SEE 12 ROOF PLAN PER F— Bxbxlb GONG. KNOGKOUT BLK. TOP ELEV. R-30 INSULATION GOUR5E - FILL W/ GONG. AND 145 BAR DONT. DRIP E06E1/2" 08-19-10 C13 Lu w =H �ic~nCO CYP5UM W. U A N J z c� M LUQ— OVER FASCIA c— � � a 41-0" 00 O FA5GIA MATERIAL TO BE I2° 0 DIAPHRAM AREA FASTEN W! 5d NAILS ALUMINUM OR 5/4' PRIME TRIMAT \` tt COL. REMAINDER AT T' O.G. BOARD OVER 2x4/2xb C.) n u w 5UBFA5GIA REFER TO SUBD. 7ACO PRE -ENURED. PRECAST GONG. LINTEL ABV. TYP. 5PEGIFIGATION5 FOR FA5GIA j WDW. AND DOOR OPN65.5EE PLANS FOR MATERIAL a LOGATION5 AND TYPES G,ONTALUM n a 112" DRYWALL OVER Ix2 P.T. (MIN) AT 24" VENTED SOFFIT z t O.G. (MAX) Lu GORE -FILL 500 FOAM INSULATION IN ALL t OPEN GMU WALL GO L5 - REFER TO o tt ENER6Y GALGULATION FOR R -VALUE 3 ii #5 VERT. BAR TIED INTO #5 BAR DOWEL TEXTURED GEMENT FINISH OVER TOP GOUR5E REBAR AT EA. REIN. Bxbxlb GONG. BLOGKAND tt GONG. FILLED BLOGK CELL AS LOCATED u PER PLANS PRECAST WN. SILL - TYP. AT STD. HDR Om. Q Q _z IIII Hi 4" MIN. 31/2" MIN. GONG. SLAB (2500 P51) W/ `~ FIBERME5H OR bxb 10/10 WWM OVER Uff VAPOR BARRIER n FIN15H GRADE _—A=�l n 11 — GLEAN GOMPAGTED TERMITE TREATED FILL MONOLITHIG SLAB E06E #5 BAR DOWEL TIED TO FTG. REBAR Ib" FOOTING PER SLAB PLAN AT EA. REIN. FILLED (,ELL AS MIN. LOCATED PER SLAB PLAN TYP. EXT. BLOCK WALL SECTION 5GALE: I/2"= I' -O" LATEST REVISION DATE TO MASTER: 08-19-10 C13 Lu w =H �ic~nCO = Q w = o Q � U A N J z c� M LUQ— O —0 c,4 LL.LTJ N LL c— � � a w 00 O 0 0 r 1 � 00 L0 w \` oc w cn Q cl) 0 C.) O w W= 7ACO O w �L UCo C0 w 0 C13 Lu w =H �ic~nCO = Q w = o Q � U A N J z c� M LUQ— O —0 c,4 LL.LTJ N LL c— � � a Z 00 O N Cy) Q r 1 � 00 L0 C O CN ` Q Lu LV W C.) J W w W= - OO �z F— Lu 0 �z > w O 0 J cf) O w �L UCo C0 w 0 C13 Lu w =H �ic~nCO = Q w = o Q � U A N J z c� M LUQ— O —0 c,4 LL.LTJ N LL c— � � a Q 00 O N Cy) Q r 1 � 00 L0 C O CN ` -T--- Lu LV W >N J W w W= Z Q F— Lu 0 1 > w w 0 J cf) DO NOT 5GALE PRINT51 G0145TRX ION 5HALL BE PER INDIGATED DIMEWNON5 ONLY, ANY D15GREPENGIE5 TO BE REPORTED TO MA HOMIE5 FOR U.ARIEIGATIONI a irre D2 M/I ORLANDO